Chapter 2 - MZX Technology

MZX Detection Panels


Tyco MX detection panels use all the features of Tyco MX Technology to provide the latest fire detection technology meeting
the latest worldwide standards in cost-effective, expandable packages.

Tyco MX detection panels support Tyco MX Technology: Tyco MX panels include advanced manager and
engineer functions including:
• MX VIRTUAL Multi-sensor detectors
• MX DIGITAL high speed reliable digital protocol • Menu driven
• MX FASTLOGIC fuzzy logic smoke detection algorithms • Multi-level password protected
• MX CCO universal carbon monoxide fire detection • Viewing 3000 event log
algorithms • Detailed fault reporting
• Isolate by point, zone or sector
Tyco MX detection panels provide modular cost effective • Viewing and printing status
solutions: • Viewing and printing isolated points
• Networked panels from 1 to 792 detection loops • Manual and automatic walk test and reporting functions
• Powerful central loop processing functions • Viewing and printing maintenance reports
• Powerful and modular user interface • Extensive diagnostic functions including simulation and
force outputs
• MX REMOTE diagnostics and service functions
• Text and configuration changes/Automatic battery test
• TXG graphical user interfaces
• Detector service functions
• MZX, MX2 and designer housing options

Tyco MX detection panels provide long term fire detection Tyco MX detection panels include very powerful event/
solutions including upgrade paths from earlier panel action programming including:
models and a long term develop-ment strategy providing
future upgrade paths. • Seamless network wide event/action
• 240 x 240 Output map and output sequencing
Tyco MX detection panels include: algorithms
• Over 3000 event/action groups for the most complex
• MZX for compact single loop solutions applications
• MINERVA MX for EN54 LPCB approved systems • Templates for fast programming of standard applications
• MINERVA T2000 for Marine approved systems including:
- EN54/BS5839
- EN54 Marine
Tyco MX detection panels include a powerful user • User defined templates
interface:
• Time, date and special day programming
• 640 Character display • Wide range of co-incidence, double knock and delay
• Displays first alarm and most recent alarm functions
• Permanently displays systems status including number
of alarms, number of faults, number of isolated points
• Scroll function allows details of all events and status to
be easily viewed
• Displays temperature, CO level and smoke level at point
in alarm
• Displays 95 character custom messages for emergency
procedures

04/13 Fire Catalogue Chapter 2 Page 1


Chapter 2 - MZX Technology
Features
• Supports one, two or 4 loops with 125, 250, 500 or 1000
addresses (panel dependant)
• 2km loop length
• High level User Interface with “Front Panel Controls” to
reduce lifetime cost of ownership
• Wide range of detectors including the 3oTec triple sensing
detector providing early detection without false alarms.
• Wide range of ancillaries including door control to BS7273
category A
• DDA compliance using AVBase and loop powered
sounder beacons.
• Approved to EN54 the system is designed to be installed
to BS5839 Part 2

Minerva® MZX Addressable Control Panels


This range of digital addressable fire control panels uses
the well established MXDigital® Loop protocol, detectors, i/o
modules, user interface and software from the MX range of
panels. They provide a single box solution ideally suited for
small and medium sized installations up to 240 zones.

The following models are available :-


MZX125 Single Loop, 125 Addresses, 16 Zones
MZX250 Single Loop, 250 Addresses, 32 Zones
MZX251 Single Loop, 250 Addresses, 32 Zones
MZX252 Two Loop, 500 Addresses, 32 Zones Product Codes
MZX253 2 to 4 Loop, up to 1000 addresses, 64 Zones 557.200.501 MZX125 1 loop 16 Zone Fire Controller
MZX254 2 to 4 Loop, up to 1000 addresses, 240 Zones 557.200.502 MZX250 1 loop 32 Zone Fire Controller
The MZX125 housing has space for 2 x 12Ah batteries 557.200.503 MZX251 1 loop 32 Zone Fire Controller
The MZX250 housing has space for 2 x 17Ah batteries 557.200.506 MZX252 2 loop 32 Zone Fire Controller
The MZX251, 252, 253 and 254 housings have space for 2 x 557.200.538 MZX253 2 to 4 loop 64 Zone Fire
38Ah batteries Controller (CPU801)
557.200.509 MZX254 2 to 4 loop 240 Zone Fire
Running the robust MXDigital® loop protocol the panels can Controller (No Zonal LED’S)
operate using most cable types. This makes them ideal for 557.202.073 2 Loop expansion kit for MZX253 (includes
upgrades as the existing cables can be utilised reducing XLM loop card)
installation time and cost. 557.200.520 MZX16R 16 Zone Repeater (mains
powered)
All panels are complete with an integral PSU which will 557.200.521 MZX32R 32 Zone Repeater (mains
support a full compliment of loop powered sounders and powered)
beacons. 557.200.526 MZX64DR 64 Zone Repeater (24VDC
powered)
The MZX250, 251, 252, 253 and 254 control panels can 557.200.523 MZXDR 240 Zone Repeater No Zonal
be fitted with the TLI800EN network interface module, Led’s (24VDC powered)
This enables up to 99 control panels to be seamlessly 557.201.502 Semi-Flush Bezel for MZX125/MZX16R
networked, or to be added to an existing network of MX Fire 557.201.501 Semi-Flush Bezel for
controllers. MZX250/251/252/253/254/MZX32R
557.201.503 Accessory mounting plate for std
Repeaters modules, IOB800, LIM800 and TUD800
Four dedicated repeaters are available. (MZX250/251/252/253/254 only)
These repeaters offer the user full panel functionality. Up 557.201.519 Comms Interface mounting plate
to 7 repeaters can be attached to the control panel’s 2 wire (MZX250/251/252/253/254 only)
remote bus. Two repeaters are mains driven with internal 557.201.510 Rack mount kit for MZX 125
mains psu & batteries and two require an external 24VDC 557.201.511 Rack mount kit for MZX 250
supply. 557.201.512 Rack Mount Kit for MZX 251/252/253/254
557.201.307 MZX250 17Ah Battery Clamp
MZX16R 16 Zones with space for 7Ah or 12Ah batteries 557.201.505 MZX251/ 252 38Ah Battery Clamp
MZX32R 32 Zones with space for 17Ah batteries 557.201.520 MZX251/252/253/254 24Ah Battery Clamp
MZX64DR 64 Zones (requires 24VDC supply)
MZXDR 240 Zones (No Zonal Led’s) (Requires 24VDC
supply)

Chapter 2 Page 2 Fire Catalogue 04/13


Chapter 2 - MZX Technology
MZX Addressable Control Panels
Technical Specifications

MZX125 MZX250 MZX251/252/253/254 MZX16R MZX32R MZX64DR/MZXDR



Dimensions
H x W x D mm 370x325x126 480x410x140 480x410x205 370x325x126 480x410x140 370x254x84
Weight 7kg 9.7kg 10.6kg 6.6kg 9.3kg 4kg
Operating Temp -5oC +40oC
Storage Temp -20oC +70oC
Humidity 90% relative Humidity Non Condensing
Housing Colour RAL7035
Facia Colour Pantone Grey 431C
EMC/RFI EN50130-4 & EN61000-6-3
Supply Voltage 230VAC 50/60 Hz 24VDC
Input Current 0.9A 1.6A 1.6A 0.9A 0.9A 250mA
Charger Size
Note 1 2.5A 5.0A 5.0A 2.5A 2.5A none
Max Battery Size 2 x 12V 12Ah 2 x 12V 17Ah 2 x 12V 38Ah 2 x 12V 12Ah 2 x 12V 17Ah none

Note 1 – Max PSE output current with the charger interrupted (I max b, EN54-4)

MZX Ancillary housings & PSUs


This range of housing & PSU’s is designed to complement the MZX range of fire controllers, the housings are available in
different sizes to match the MZX fire controller. Two ranges of ancillary housing are available; one is designed to
accommodate various modules on the removable chassis plate and also has the option to mount a document holder on
the rear of the door. The other ancillary housings, (aperture housings) are designed to accommodate one or two stand-
ard sized MX control, display, printer or annunciator modules ie ANN880, COM820, PRN800 or similar, a chassis plate for
mounting modules is also fitted.

The housings with two apertures are supplied with one blanking plate

Product Codes
557.202.625 ANC125-A Ancillary Housing, One Aperture (Small - matches MZX125)
557.202.626 ANC250-A Ancillary Housing, Two Aperture (Large – matches MZX250)
557.202.627 ANC251-A Ancillary Housing, Two Aperture (Deep – matches MZX251/252/253/254)
557.202.622 ANC125 Ancillary Housing (Small - matches MZX125)
557.202.623 ANC250 Ancillary Housing (Large – matches MZX250)
557.202.624 ANC251 Ancillary Housing (Deep – matches MZX251/252/253/254)
557.201.513 Document Holder attachment (used with ANC125/250/251)
557.201.518 M520 Anc Fitting Kit – req’d for older M520 modules, fittings for 4 modules

Power Supply Units


The power supplies utilise switch mode PSU’s as used in the MZX range of panels, if monitoring of these PSU’s is required
a monitoring kit is available which includes a MIM800, mounting bracket and cables

557.200.530 PSU A17 17Ahr 5A Addressable expansion PSU - matches MZX250


557.200.531 PSU A38 38Ahr 5A Addressable expansion PSU - matches MZX251/252/253/254

557.201.516 PSU monitor kit (includes MIM800)

04/13 Fire Catalogue Chapter 2 Page 3