The dimming range will be significantly shorter when using F17T8, F25T8 (3ft) or when delamping UltraMax® Dimming ballasts. Please see
GELighting.com product specifications for a complete listing of product specifications by ballast, lamp type and number of lamps per ballast.
Lighting
10 Pack Pallet Input Starting Ballast #
Code Code Description Voltage Method Switch Method Factor (F32T8) Lamps
71497 71502 GE632MAX90-S60 120-277 Instant Start Bi-Level 100% to 60% 1.18 - .71 6
UltraMax® Dimming
71731 71732 GE632MAX90-V60 120-277 Instant Start Variable 0-10V 100 to 60% 1.18 - .71 6
73229 GE432MAX90-S60 120-277 Instant Start Bi-Level 100% to 60% 1.18 - .71 4
73230 GE432MAX90-V60 120-277 Instant Start Variable 0-10V 100 to 60% 1.18 - .71 4
73231 GE332MAX90-S60 120-277 Instant Start Bi-Level 100% to 60% 1.18 - .71 3
73232 GE332MAX90-V60 120-277 Instant Start Variable 0-10V 100 to 60% 1.18 - .71 3
73233 GE232MAX90-S60 120-277 Instant Start Bi-Level 100% to 60% 1.18 - .71 2
# of Lamps # of Lamps
F32T8HL
Initial Lumens
3100
System Watts 100%
2
2H
74
3
3H
110
4
4H
146
6
6H
215
BF F28T8
Initial Lumens
2750
System Watts
2
2H
62
3
3H
93
4
125
4H
184
6
6H BF Instant Start Ballasts
System Lumens 7316 10974 14632 21948 System Lumens 6490 9735 12980 19470
100% Lumens per Watt 99 100 100 102 1.18 100% Lumens per Watt 105 105 104 106 1.18
Watts per sq. ft. 0.7 1.1 1.5 2.2 Watts per sq. ft. 0.6 0.9 1.3 1.8
Est Avg Foot Candles 53 79 105 158 Est Avg Foot Candles 47 70 93 140
System Watts 59 88 117 188 System Watts 54 79 110 166
System Lumens 5828 8742 11656 17484 System Lumens 5308 7961 10615 15923
80% Lumens per Watt 100 99 100 93 0.94 80% Lumens per Watt 98 101 97 96 0.97
Watts per sq. ft. 0.6 0.9 1.2 1.9 Watts per sq. ft. 0.5 0.8 1.1 1.7
Est Avg Foot Candles 42 63 84 126 Est Avg Foot Candles 38 57 76 115
System Watts 30% 43 66 87 132 System Watts 46 65 94 122
System Lumens 4402 6603 8804 13206 System Lumens 4125 6188 8250 12375
60% Lumens per Watt 102 100 101 100 0.71 60% Lumens per Watt 90 95 88 101 0.75
Watts per sq. ft. 0.4 0.7 0.9 1.3 Watts per sq. ft. 0.5 0.7 0.9 1.2
Est Avg Foot Candles 32 48 63 95 Est Avg Foot Candles 30 45 59 89
Energy Savings (W) 31 44 59 83 Energy Savings (W) 16 28 31 62
g
1-888-GEBALLAST (432-2552)
For product specifications and application information, please consult GE’s Website: www.gelighting.com
Information provided is subject to change without notice. Please verify all details with GE. All values are
imagination at work Transforming the POWER of LightTM
design or typical values when measured under laboratory conditions, and GE makes no warranty or
© 2013 GE 73506 01/2013 Printed in USA guarantee, express or implied, that such performance will be obtained under end-use conditions.
Line Voltage Dimming 0-10V Low Voltage Dimming
GE revolutionizes lighting again
S60 Application #1 – High Low Sensor Switching V60 Application #1 – Variable Load Shed Dimming
with the new UltraMax® Dimming BLACK Line
Line BLACK Line
WHITE BLUE BLUE
WHITE Line
In the GE labs, our engineers have developed ballasts that are
Switching BALLAST BLUE GRAY Line BALLAST BLUE
Line Black Line RED RED
VIOLET Line
the highest efficiency, lowest watts and allow various light levels
0-10V Low Voltage Wire
without sacrificing efficiency during dimming.
The innovative, patented technology in our Platinum UltraMax® LAMP LAMP
electronic ballasts allow more flexibility in lighting design then Motion = 100% Light/Watts
Power On
0 Volts = 60%
ever before at an affordable price well below conventional Vacant = 60% Light/Watts LAMP 5 Volts = 80% LAMP
Multi-Voltage Arc-Guard Xtreme High Temp Power Off = 0% Light/Watts 10 Volts = 100%
Control Protection Efficiency Application dimming ballasts. *Switch many fixtures with one occupancy sensor Variable dimming 60-100%
Multi-Voltage technology means a single UltraMax® model handles voltage from S60 Application #2 – Two Switch V60 Application #2 – H 1.18 (High Light)
120 through 277 BLACK Line
Line 1 BLACK Line
UltraMax® Ballasts can virtually "read" the incoming voltage and adapt automatically to any voltage from WHITE Switching
BLUE
WHITE Line
BLUE
108V to 305V. The benefits of Multi-Voltage Control (MVC) are obvious. Neutral BALLAST BLUE GRAY Line BALLAST BLUE
Black Line RED Insulate Gray and RED
Line 2 Violet separately VIOLET Line
(Open circuit)
“Tunable” ballast factor (light level) 0-10V Low Voltage Wire
The most versatile line of ballasts available. With just four ballasts you can design your lighting system to operate one through six
of the F32T8 family of lamps including the GE Ultra energy saving lamps, select a light level between ~3400 to 22,000 lumens with LAMP LAMP
Switch 1 On/2 Off = 60% Light/Watts
Switch 1 On/2 On = 100% Light/Watts
a system wattage ranging between 34 to 215 watts without sacrificing system efficiency. Design your lighting system to “tune” the Switch 2 On/1 Off = 60% Light/Watts
LAMP LAMP
light level to the ambient light or scenes desired while saving up to 40% by dimming! Switch 1 & 2 Off = 0% Light/Watts
*6H - Switch 2 On/1 Off = 0% Light/Watts
GE’s UltraMax® line is the only full line of T8 ballasts with a UL Type CC Anti-Arc Rating
UL Type CC Rating is a stringent designation for protection against arcing in electrical devices. GE's Arc-Guard design eliminates the S60 Application #3 – H 1.18 (High Light) V60 Application #3 – H .71 (Low Watt)
damaging effects arcing can have on lamps, ballasts and sockets.
BLACK Line
Line BLUE BLACK Line BLUE
Black Line WHITE Line
High efficiency delivers over 40% energy savings. BALLAST BLUE GRAY Line BALLAST BLUE
WHITE Neutral RED RED
AllUltraMax® ballasts exceed the NEMA Premium® minimum efficiency requirements. The Platinum VIOLET Line
UltraMax® 6H ballast establishes a new energy efficiency threshold at 95% ballast efficiency! 0-10V Low Voltage Wire
Systems combining UltraMax® electronic ballasts and T8 energy saving lamps deliver over 40% energy
savings over standard T12 systems. Where and when light can be lowered reduce your energy costs 6H gray wire connect to line
LAMP
Insulate Gray and
LAMP
or neutral will operate at Violet together
by an additional 40% for a possible 80% total reduction over standard T12 systems. 100% light (Closed circuit)
Starts high fades low
LAMP (~1 second)
LAMP
-20F Minimum Starting Temperature.
Cold temperature starting performance with standard T8 lamps.
S60 Application #4 – L .71 (Low Watt) Safety & Performance Application Information
UL 55C Ambient Rating. BLACK Line
• No PCBs • Minimum Starting
GE’s UltraMax®'s patented high temperature protection circuit ensures ballasts run cool in high temperatures. Line BLUE • FCC Class A Temp: -20°F, -18°C
Black Line
UltraMax® is one of the only electronic T8 ballasts that pass UL’s stringent high temperature testing requirements (insulated) BALLAST BLUE • UL Listed • Anti-Striation Control
for safe operation up to 55C ambient environments. WHITE Neutral
RED -UL 55C • Sound Rated A
Ambient Rating • Remote Mounting:
Anti-Striation Control for better light quality, with no striations. -Type 1 Outdoor -18' maximum length,
UltraMax®’s patented Anti-Striation Control circuit eliminates lamp striations, often referred to as spiraling or 6H Insulate gray lead (open)
LAMP -Type CC -18 AWG
Starts high fades low
racoon tailing. This provides a flicker- and worry-free environment. (~1 second) -Type HL • High Frequency Lamp
LAMP (Hazardous Location) Operation: ~ 68 kHz
A big idea in a small package.
The Platinum UltraMax® 2H, 3H and 4H ballast has a small, low profile 9.5 x 1.7 x 1.2” housing.
The 6H makes T8 highbay assembly faster and easier with just one ballast in an amazing UltraMax® Dimming are instant start ballasts and are limited to approximately 5 on/off cycles per day to avoid significantly shortening lamp life. It is not
11.14 x 1.7 x 1.2” housing. That means fixture designs can be more compact and streamlined. recommended to use sensors to control ballast on/off cycles and doing so may void lamp warranty. However sensors may be used on the high low switching
. wire and gray/violet input of the ballast with the sensor setting recommended no less than 5 minutes per cycle without sacrificing lamp life.