Sunteți pe pagina 1din 7

www.hilti-me.com Profis Anchor 2.8.

6
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/11/2020
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HIT-HY 200-R + HIT-V (8.8) M10
Return period (service life in years): 50
Effective embedment depth: hef,opti = 60 mm (hef,limit = 170 mm)
Material: 8.8
Evaluation Service Report: ETA 12/0084
Issued I Valid: 8/28/2019 | -
Proof: Design method EN 1992-4, Chemical
Stand-off installation: eb = 0 mm (no stand-off); t = 12 mm
Anchor plate: S 275; E = 210,000.00 N/mm2; fyk = 275.00 N/mm2; gMs = 1.000
lx x ly x t = 200 mm x 200 mm x 12 mm; (Recommended plate thickness: calculated (6 mm))
Profile: Double flat bar, ; (L x W x T) = 100 mm x 100 mm x 12 mm
Base material: cracked concrete, C20/25, fc,cyl = 20.00 N/mm2; h = 200 mm, Temp. short/long: 30/40 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.8.6
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/11/2020
E-Mail:

1.1 Sustained loads


Nsus [kN] Mx,sus [kNm] My,sus [kNm]
0.000 0.000 0.000

2 Load case/Resulting anchor forces (ULS) y


Load case: Design loads
3 4

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 3.319 0.208 -0.207 -0.023
x
2 3.319 0.208 -0.207 -0.023
3 3.319 0.208 -0.207 -0.023 Tension
4 3.319 0.208 -0.207 -0.023

max. concrete compressive strain: - [‰]


max. concrete compressive stress: - [N/mm2] 1 2
resulting tension force in (x/y)=(0/0): 13.274 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN]

Anchor forces are calculated based on the assumption of a rigid anchor plate.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.8.6
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/11/2020
E-Mail:

3 Tension load (EN 1992-4, Section 7.2.1)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 3.319 30.933 11 OK
Combined pullout-concrete cone failure** 13.274 23.385 57 OK
Concrete Breakout Strength** 13.274 31.578 43 OK
Splitting failure** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength


NRk,s [kN] gM,s NRd,s [kN] NEd [kN]
46.400 1.500 30.933 3.319

3.2 Combined pullout-concrete cone failure


Ap,N [mm2] A0p,N [mm2] t Rk,ucr,20 [N/mm2] scr,Np [mm] ccr,Np [mm] cmin [mm] fc,cyl [N/mm2]
99,200 32,400 15.00 180 90 80 20.00
yc t Rk,cr [N/mm2] k3 t Rk,c [N/mm2] y 0g,Np y g,Np
1.000 6.00 7.700 8.49 1.406 1.048
ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np
0 1.000 0 1.000 0.967 1.000
y 0sus asus y sus
0.890 0.000 1.000
N0Rk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NEd [kN]
11.310 35.078 1.500 23.385 13.274

3.3 Concrete Breakout Strength


Ac,N [mm2] A0c,N [mm2] ccr,N [mm] scr,N [mm] fc,cyl [N/mm2]
99,200 32,400 90 180 20.00
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 0.967 1.000
z [mm] y M,N k1 N0Rk,c [kN] gM,c NRd,c [kN] NEd [kN]
0 1.000 7.700 16.004 1.500 31.578 13.274

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.8.6
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/11/2020
E-Mail:

4 Shear load (EN 1992-4, Section 7.2.2)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 0.208 18.560 2 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 0.832 46.770 2 OK
Concrete edge failure in direction x-** 0.828 9.194 10 OK
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


V0Rk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
23.200 1.000 23.200 1.250 18.560 0.208

4.2 Pryout Strength (Bond Strength controls)


Ap,N [mm2] A0p,N [mm2] t Rk,ucr,20 [N/mm2] ccr,Np [mm] scr,Np [mm] cmin [mm] fc,cyl [N/mm2]
99,200 32,400 15.00 90 180 80 20.00
yc t Rk,cr [N/mm2] k3 t Rk,c [N/mm2] k8 y 0g,Np
1.000 6.00 7.700 8.49 2.000 1.406
y g,Np ec1,V [mm] y ec1,Np ec2,V [mm] y ec2,Np y s,Np
1.048 0 1.000 0 1.000 0.967
y re,Np y 0sus asus y sus
1.000 0.890 0.000 1.000
N0Rk,p [kN] NRk,p [kN] gM,c,p VRd,cp [kN] VEd [kN]
11.310 35.078 1.500 46.770 0.832

4.3 Concrete edge failure in direction x-


lf [mm] dnom [mm] k9 a b fc,cyl [N/mm2]
60 10.0 1.700 0.087 0.066 20.00
c1 [mm] Ac,V [mm2] A0c,V [mm2]
80 45,600 28,800
y s,V y h,V y a,V ec,V [mm] y ec,V y re,V
1.000 1.000 1.001 0 1.000 1.000
V0Rk,c [kN] kT gM,c VRd,c [kN] VEd [kN]
8.700 1.0 1.500 9.194 0.828

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.8.6
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/11/2020
E-Mail:

5 Combined tension and shear loads ( EN 1992-4, Section 7.2.3)

Steel failure
bN bV a Utilization bN,V [%] Status
0.107 0.011 2.000 2 OK
baN + baV ≤ 1.0

Concrete failure
bN bV a Utilization bN,V [%] Status
0.568 0.090 1.500 46 OK
baN + baV ≤ 1.0

6 Displacements (highest loaded anchor)


Short term loading:
NSk = 2.458 [kN] dN = 0.130 [mm]
VSk = 0.307 [kN] dV = 0.018 [mm]
dNV = 0.132 [mm]
Long term loading:
NSk = 2.458 [kN] dN = 0.287 [mm]
VSk = 0.307 [kN] dV = 0.025 [mm]
dNV = 0.288 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements are valid
without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not included in this
calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

7 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.). This means load
re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in
order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum required anchor plate thickness with FEM to
limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by
PROFIS Anchor. Input data and results must be checked for agreement with the existing conditions and for plausibility! 
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters of the
clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be followed
to ensure a proper installation.
• For the determination of the Psi_re,v (concrete edge failure) a concrete cover of the edge reinforcement c = 30 mm is assumed
• Bore hole cleaning must be performed according to instructions for use (blow twice with oil-free compressed air (min. 6 bar), brush twice, blow twice
with oil-free compressed air (min. 6 bar)).
• Characteristic bond resistances depend on short- and long-term temperatures.
• Please contact Hilti to check feasibility of HIT-V rod supply.
• Edge reinforcement is not required to avoid splitting failure
• The characteristic bond resistances depend on the return period (service life in years): 50

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.8.6
Company: Page: 6
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/11/2020
E-Mail:

8 Installation data
Anchor plate, steel: S 275; E = 210,000.00 N/mm2; fyk = 275.00 N/mm Anchor type and diameter: HIT-HY 200-R + HIT-V (8.8) M10
Profile: Double flat bar, ; (L x W x T) = 100 mm x 100 mm x 12 mm Installation torque: 0.020 kNm
Hole diameter in the fixture: df = 12 mm Hole diameter in the base material: 12 mm
Plate thickness (input): 12 mm Hole depth in the base material: 60 mm
Recommended plate thickness: calculated (6 mm) Minimum thickness of the base material: 100 mm
Drilling method: Hammer drilled
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required

8.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required accessories to • Dispenser including cassette and mixer
• Properly sized drill bit blow from the bottom of the hole • Torque wrench
• Proper diameter wire brush
y

100 100

30
3 4

100
140

x
100

1 2
30

30 140 30

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -70 -70 80 360 - -
2 70 -70 220 220 - -
3 -70 70 80 360 - -
4 70 70 220 220 - -

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.8.6
Company: Page: 7
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/11/2020
E-Mail:

9 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the
relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you
bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole
responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms
and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to
the absence of errors, the correctness and the relevance of the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the
AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by
carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs,
arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan