Sunteți pe pagina 1din 16

C 24 innovation uplifted to maximum efficiency

Central Battery System


Technology based on experience
We are experts in technology. And we are so based on our own experience.

What we know and what we do is the result of more than 40 years of work
focused towards the search in our products of an excellence that makes us
win the confidence of our customers.

Also, we have been guided by the same values: a willingness for the
constant learning and and a growth eagerness always in balance with
our responsibility as a friendly company, where all the processes (design,
production, quality) are focused on the customer.

This is the basis on which we continue to grow.

NormaGrup has been born to integrate the Corporate diversity of our


production, aiming to offer even more expert solutions for the specific
needs of our Customers. NormaGrup’s structure includes five divisions:
NormaLux, emergency lighting, NormaDet, fire detection systems,
NormaLit, technical and architectural lighting, OrnaluxClinic, technical
systems for hospitals, and EcoLight, emergency lighting.

NormaGrup, present and future solutions.


technology at equilibrium

By using Normalux’ technology,


a 50% save of electrical
consumption is achieved.

LED

Lower CO2 Recyclable Battery Eye LED Domotic


emissions material protection protection technology control
system system
innovation uplifted to maximum efficiency

NormaLux is the leader in emergency lighting. Our long experience, our constant bet on
the learning at the technological cutting edge, and the excellent balance quality/price of our
products has given us the confidence of our national and international customers. Also, that of
the Quality Control agencies, that have granted us with certificates such as the ISO9001, TÜV
Product Service or ENEC.

We have been pioneers in leaving behind the incandescent and fluorescent technologies
looking for a bigger performance and energetic efficiency. We have been the first to apply the
LED technology to all of our production, that nowadays exceeds the million units per year.

01
C 24
Central
Battery Manufactured according

System UNE-EN 50171 regulation

C24-100

C-24 Central Battery System powers emergency


lighting luminaires with 24v DC.

Depending on the output, there are two models:


C24-100 (100w) and C24-300 (300w).
CBS
These are intelligent control panels that give
warnings in case of any anomaly occurring on the
fittings or the lines where the emergency lights are
connected.

Remote control from a computer.

4 24v DC outputs available.

3 24v DC relay outputs (max. 50w) controlled by


BUS available.
C24-300 COVERS ONE FIRE SECTOR
STATUS LED control
SELF-TESTING SYSTEM

(FUNCTIONAL TEST
+ duration test)

Status LED on: OK Status LED blinking: FAILURE

Technical data:
WIRE MAXIMUN LENGHT*
• Connection voltage: 230 V AC +/- 10%. SECTION CURRENT
• Terminal mains supply: 2,5 mm2.
• Output voltage: 24 V DC +/- 20%. 1 A 147 m
• Terminal outgoing circuits: 2,5 mm2.
1,5 mm2 2 A 74 m
• Amb. temp. range: -5ºC to 25ºC.
3 A 49 m
• Protection class: I.
• Protection category: IP30. 1 A 245 m
• Final circuits: 4. 2,5 mm2 2 A 123 m
• Max. load: 3,5 A per final circuit. 3 A 82 m
• Dimensions:
* Length for double wire and charge at the end of line.
:: C24-100: 340 x 330 x 90 mm.
:: C24-300: 500 x 400 x 200 mm.

models
C24-100 C24-300
BATTERIES 2 x 12 V · 7 Ah 2 x 12 V · 9 Ah 2 x 12 V · 12 Ah 2 x 12 V · 18 Ah 2 x 12 V · 24 Ah
DURATION 1h 3h 8h 1h 3h 8h 1h 3h 8h 1h 3h 8h 1h 3h 8h
TOTAL POWER OUTPUT (W) 88 W 36 W 14 W 115 W 48 W 19 W 154 W 66 W 27 W 234 W 105 W 42 W 314 W 136 W 58 W
MAXIMUM CURRENT (A) 3.86 1.70 0.76 4.97 2.19 0.97 6.62 2.92 1.30 9.94 4.39 1.95 13.25 5.85 2.60
SENSE LOOP YES YES
LIGHT SEQUENCE SWITCHING INPUTS 4 4
Potential free contact relay YES YES
SYSTEM WORK YES YES
BATTERY SUPPLY YES YES
FAIL YES YES
Power supply indicator YES YES
Battery supply indicator YES YES
FAIL / ALARM indicator YES YES
Total discharge indicator YES YES
ACTIVE OUTPUT indicator YES YES
BUS COM YES YES
intelligent system guarantee the correct functioning of the installation at any time
optimize the mainteinance of the installation

Control Software NormaLux Control Software NormaLux

Remote control Remote control


IPhone / IPad internet IPhone / IPad
local

Software SCADA SCADA SCADA Software SCADA

(*) MODEM

(*) ROUTER

IETHBUSING TCP/IP
Gateway

C-NB PLUS cnb plus

Control Software NormaLux Local control


C24 C24
Power supply
12 Vdc
Software SCADA SCADA

IROUTING

Self-contained emergency lights


and Central battery systems
Up to 250 fittings

IROUTING

Up to 250 IROUTING

C24
Twisted pair of wire Twisted pair of wire 12 Vdc power supply. RJ-45.
(0,5-1,5 mm2) (0,5-1,5 mm2) Pair of wire (0,5-1,5 mm2)

Self-contained 24 Vdc emergency C24 range (CBS)


* Devices not provided by NormaLux
emergency light light for CBS
SCADA
IPhone / IPad

out 1

NormaLux’ Intelligent System


represents the total and
out 2 most advanced control of an
emergency lighting installation.
The fittings are autonomous,
they carry out a periodical self-
diagnosis and offer information
about the anomalies by means
out 3 of its LEDs. Furthermore, the
control of all the devices is
centralized, which guarantees
an important save in time and
resources in the mainteinance
of your installation.
out 4 EN 50172 compliant
LED 24VDC
maximum light, minimum space

VIA LED is the physical expression of a new concept in the Emergency


Lighting field. Its small size, its discrete presence and its versatility, make it
indispensable in the modern installations that are brilliant and efficient.

With VIA LED, the light can be focused longitudinally along halls or
corridors, or projected in its round shape in open areas.

EN 60598-2-22 compliant
230V 50/60 Hz - PC - IP20 - IK04
166
3,5

50 ø 50
209
215

33,5

35 187 27
33
30
models

REF. VERSION LIGHTING LAMP CONSUMPTION CURRENT LUMENS


VERSION

VV-S2L24 CBS Corridor 2 LED 1.92 W 0.08 A 170 lm


VS-S2L24 CBS Area 2 LED 1.92 W 0.08 A 170 lm

VV
180° 120°
POSITION HEIGHT (m)
300
105°
3 4
90°
Width of corridor: 2 m. 5,8 6,4
300
75°

Goal: 1 lux 600


16,0 17,4
6,4 3,6
60°

900

45°
2,6 1,8
1200

1500
• Please pay attention to the orientation
30° 15° 0° 15° 30°
of the luminarie when installing model VV.
180-0 270-90 Cd/klm
• For higher installation options, please contact us.

16 meters

h = 3 meters

28,8 meters

VS
Technical features:
180° 120°
HEIGHT (m) AREA (m2)
• Zamak Housing, polycarbonate
80
105°

reflector. Goal: 1 lux 90° 2,5 36,3


• Power Supply 24 Vdc. 80
75°
3,0 38,5
• Bicolor LED (Charging / Failure). 160 4,0 36,3
60°
• Test button. POSITION HEIGHT (m) 240 5,0 28,3
• Suitable to be mounted on
3 4 5 45°
6,0 12,6
flammable surfaces.
320

• Class II. 8,7 9,2 9,1 400


In model VS, the orientation of the
30° 15° 0° 15° 30°
luminarie does not affect the light
• Surface or recessed mounting. 3,5 3,4 3,0 180-0 270-90 Cd/klm
distribution.
• High Efficiency lenses.
• Up to 62 VIA LED 24 Vdc using
C24-100 Central.
• Up to 165 VIA LED 24 Vdc
using C24-300 Central.
• Warning of failures through h = 3 meters
the charge LED.
Area covered with 1 lux = 38,5 m2
EXCELLENCE
the perfect mix of style and function
EN 60598-2-22 compliant
230V 50/60 Hz - PC - IP42 - IK04

• IP 42.
• IK 04.
• Power Supply 24 Vdc.
• Bicolor LED (Charging / Failure).
• Test button.
• Suitable to be mounted on flammable surfaces.
• Class II.
163

• Surface or recessed mounting.

REF. VERSION LAMP CONSUMPTION CURRENT LUMENS

E-S32L24 CBS 32 LED 2.64 W 0.11 A 200 lm


EXTRAPLANA
maximum efficiency in minimum space
EN 60598-2-22 compliant
230V 50/60 Hz - ABS+PC - IP42 - IK04

• IP 42.
• IK 04.
• Power Supply 24 Vdc.
• Bicolor LED (Charging / Failure).
• Test button.
• Suitable to be mounted on flammable surfaces.
• Class II.
• Surface or recessed mounting.

REF. VERSION LAMP CONSUMPTION CURRENT LUMENS

F-S3L24 CBS 3 LED 3 W 0.125 A 180 lm


EUROPRISMA
more accesible technology
EN 60598-2-22 compliant
230V 50/60 Hz - PC - IP65 - IK07

• IP 65.
• IK 07.
• Power Supply 24 Vdc.
• Bicolor LED (Charging / Failure).
• Test button.
• Suitable to be mounted on flammable surfaces.
• Class II.
• Surface or recessed mounting.

REF. VERSION LAMP CONSUMPTION CURRENT LUMENS

EH-S3L24 CBS 3 LED 3 W 0.125 A 180 lm


SIGNAL
exit sign

• IP 20.
• Power Supply 24 Vdc.
• Bicolor LED (Charging / Failure).
• Test button.
• Suitable to be mounted on flammable surfaces.
• Class II.
• Surface or recessed mounting.

REF. VERSION LAMP CONSUMPTION CURRENT LUMENS

SG-S24 CBS 9 LED 1.56 W 0.065 A —


González Soriano, S.A.
Parque Tecnológico de Asturias. Parcela 10
33428 Llanera (Asturias)
España / Spain
T. +34 985 267 100
F. +34 985 266 992
normalux@normalux.com
www.domotic-lighting.com
www.normalux.com

S-ar putea să vă placă și