Dual Snap®

Pressure, Temperature and Liquid Flow

www.ccsdualsnap.com

Looking for proven off-the-shelf or customizable


Industrial pressure or temperature sensing solutions?
CCS is the known choice for Markets and Applications
including:
Oil and Gas Equipment
Wellhead Automation
Storage Tank Level Monitoring
Chemical Injection
Hydraulic and Lubricating Oil Reservoirs
Fracturing Truck Monitoring
Tote Level Monitoring
Spark Protection in Diesel Fuel Distribution
Pipeline Monitoring
CNG Vehicle Conversion

Power Generation / Utilities


Gas / Steam Turbines
Boilers, Pumps, Compressors

Construction / Agricultural / Forestry Equipment


Brake Pressure Monitoring
System Pressure Monitoring
Steering Pressure Monitoring
Oil Pressure Monitoring in Drivetrain
Oil Pressure in the Transmission

Food / Beverage Benefits:


Water Connection Monitoring * Proven reliable technology
Ozone Analyzers * Rugged, stable, highly accurate
Gas Pipe System monitoring and repeatable, shock and vibration
Irrigation System Monitoring
resistant
* Superior economic value
Medical Device
Water Connection Monitoring Tested and Proven:
Gas Monitoring
Features:
* Pressure ranges from hazardous and non-hazordous standards including:
0.7” H2O to 16,000 psi • UL/cUL
Large Production Machinery * Life ranges up to • ATEX
Press Machines
Plastic Molding Injection Machines 1 million operating cycles • CCC
Paper Cutting Machines * Proof pressures up to • CE
Cold Forming Machines 25,000 psi • CRN
Welding Machines • CSA
Tire Assembly Machines • Dual Seal
• GOST
Time-Tested Solutions. Reduced Costs & Time. • NACE/NEMA
When It Absolutely Has to Work. * Tested to be used for both standard cold and hot
temperature applications from -40° to 186°F (-40° to 86°C)
Company Headquarters * Tested for use in various environments including:
21111 Plummer Street salt spray, temperature cycling, humidity, sand and
Chatsworth, California 91311 dust, moisture resistance
Tel: +1 818.341.4610 * Electrical characteristic testing including: dielectric,
switchnet@ccsdualsnap.com insulation resistance, and contact resistance
Dual Snap®
Pressure, Temperature and Liquid Flow
www.ccsdualsnap.com
Hazardous Area Products
6900GE / 6900PE Gage 6905GZE-7042 / 6905PE-7042 Gage
6900DZE / Differential 6905DZE-7042 / Differential
• Diaphragm Sensor • Piston Sensor • Diaphragm Sensor • Piston Sensor
• Adjustable Range: • Adjustable Range:
0.4-16,000 PSI 0.5-16,000 PSI
0.028-1,103 BAR 0.03-1,103 BAR
2.76-110,316 kPa 3.45-110,316 kPa
• Proof Pressures up to: • Proof Pressures up to:
25,000 PSIG 25,000 PSIG
1,724 BAR 1,724 BAR
172,369 kPa 172,369 kPa
• Weight: 16-49 ounces (467-1372 grams) • Weight: 16-49 ounces (467-1372 grams)

611GE / Gage
6900GCZZE5Y / 6900PZZE5Y Gage
611VE / Vacuum
• Diaphragm Sensor • Piston Sensor
• Diaphragm Sensor
• Adjustable Range:
• Adjustable Range:
1-16,000 PSI
28.5" Hg Vacuum-180 PSIG
0.07-1,103 BAR
724 mm Hg-12.4 BAR
6.89-110,316 kPa
96.5-1241 kPa
• Proof Pressures up to:
• Proof Pressures up to:
25,000 PSIG
1000 PSIG
1,724 BAR
68.9 BAR
172,369 kPa
6895 kPa
• Weight: 16-25 ounces (467-708 grams)
• Weight:10-20 ounces (283-567 grams)

675GE / 675GE800 Gage


672DE / 673DE Differential 675DE / 675DE800 Differential
• Diaphragm Sensor 675VE / 675VE800 Vacuum
• Adjustable Range: • Diaphragm Sensor
2-150 PSID • Adjustable Range:
0.14-10.3 BAR 0.7-31" H20
13.79-1034 kPa 1.7-77.2 mBAR
• Proof Pressures up to: 0.17-7.72 kPa
4500 PSIG • Proof Pressures up to:
310 BAR 15 PSIG
31,026 kPA 1034 mBAR
• Weight: 67 ounces (1876 grams) 103.4 kPa
• Weight: 22 ounces (624 grams)

646GE / Gage 646DZE / 646DCE Differential


646TE (Probe)
646VE / Vacuum 646GVE / Crossover
646TUE (Capillary)
• Diaphragm Sensor
Temperature
• Adjustable Range:
• Diaphragm Sensor
28.5" Hg Vacuum-5000 PSIG
• Adjustable Range:
724 mm Hg-345 BAR
-39 deg F to +630 deg F
96.5-34,500 kPa
-39 deg C to +332 deg C
• Proof Pressures up to:
• Maximum Probe Temperature up to +650 deg F
7,500 PSIG
(+343 deg C)
517 BAR
• Weight: 68-71 ounces (1928-2013 grams)
51,700 kPa
• Weight: 60 ounces (1700 grams)

6900TE (Probe) 6905TE-7042 (Probe)


6900TUE (Capillary) 6905TUE-7042 (Capillary)
Temperature Temperature
• Diaphragm Sensor • Diaphragm Sensor
• Adjustable Range: • Adjustable Range:
0 deg F to +650 deg F 0 deg F to +650 deg F
-18 deg C to +340 deg C -18 deg C to +343 deg C
• Maximum Probe Temperature up to +700 deg F • Maximum Probe Temperature up to +700 deg F
(+371 deg C) (+371 deg C)
• Weight: 32 ounces (907 grams) • Weight: 35 ounces (992 grams)

© 9.2014 Custom Control Sensors, Inc. Custom-tailored solutions to fit a variety of industrial applications are available. See www.ccsdualsnap.com
Dual Snap®
Pressure, Temperature and Liquid Flow

www.ccsdualsnap.com
www.ccsdualsnap.com

Non-Hazardous Area Products


6900G / 6900P 604G / 604P Gage
Gage Pressure 604D / Differential
604V / 604GV Vacuum Crossover
• Diaphragm Sensor
• Piston Sensor • Diaphragm Sensor
• Adjustable Range: • Piston Sensor
1-16,000 PSIG • Adjustable Range:
0.07-1,103 BAR 28.5" Hg - 5000 PSIG
6.89-110,316 kPa 724 mm Hg - 345 BAR
• Proof Pressures up to: 96.5-34,474 kPa
25,000 PSIG • Proof Pressures up to:
1,724 BAR 10000 PSIG
172,369 kPa 689 BAR
• Weight: 15 ounces (425 grams) 68,948 kPa
• Wetted material options for material capability • Weight: 35 ounces (992 grams)
• Wetted material options for material capability
605G / 605P Gage
605D / Differential
674D
605V / Vacuum
Differential
• Diaphragm Sensor
• Diaphragm Sensor
• Piston Sensor
• Adjustable Range:
• Adjustable Range:
2-800 PSID
28.5" Hg - 5000 PSIG
0.138-55.16 BAR
724 mm Hg - 345 BAR
13.8-5515 kPa
96.5-34,474 kPa
• Proof Pressures up to:
• Proof Pressures up to:
4500 PSIG
10000 PSIG
310 BAR
689 BAR
31,026 kPA
68,948 kPa
• Weight: 45 ounces (1275 grams)
• Weight: 39 ounces (1092 grams)
• Wetted material options for material capability

675G800 / Gage
675D800 / Differential 6900T / 6900TU (Capillary)
675V800 / Vacuum Temperature

• Diaphragm Sensor • Diaphragm Sensor


• Adjustable Range: • Adjustable Range:
0.2-31” H20 0 deg F to +650 deg F
0.5-77.2 mbar -18 deg C to +340 deg F
0.05-7.72 kPa • Maximum Probe Temperature up to +700 deg F
• Proof Pressures up to: (+371 deg C)
25 PSIG • Weight: 21 ounces (595 grams)
Electrical Connector
1.72 BAR
Conforms to DIN 43650
172 kPa
• Weight: 19 ounces (538 grams)

611G / Gage
611V / Vacuum 604T / 604TU (Capillary)
Temperature
• Diaphragm Sensor
• Adjustable Range: • Diaphragm Sensor
0.75-180 PSIG • Adjustable Range:
0.0517-12.4 BAR -39 deg F to +630 deg F
5.17-1241 kPa -39 deg C to +332 deg C
• Proof Pressures up to: • Maximum Probe Temperature up to +650 deg F
1000 PSIG (+343 deg C)
68.9 BAR • Weight: 65 ounces (1843 grams)
6895 kPa
• Weight:10-20 ounces (283-567 grams)
• Wetted material options for material capability

© 9.2014 Custom Control Sensors, Inc.