Sunteți pe pagina 1din 43

Australia Products

Since 1973
A Member of The Elta Group U.K 

FANS SELECTION

Documents included:

- Fan Performance Curve & Drawing for Each Fan

- General catalogue
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model AP0404AA10/28

Location: EAF-1F-01A,01B Designation:

Performance - Required Actual


Air Flow : 800 L/s Air Flow: 807 L/s
Static Pressure : 150 Pa Static Pressure: 152 Pa
Selection Pressure: 150 Pa Total Pressure: 177 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: AP0404AA10/28 (AP0404AA10B003)
Description: AP Series In-Line Direct Drive

Diameter: 400 mm Hub: 150 mm


Impeller Type: Axial Pitch: 28°
Blade Material: Aluminium Blades: 10
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 0.26 kW Peak: 0.26 kW
Input Power: 0.36 kW
Efficiency Total: 55.9% Static: 48.1%
Fan Weight: 26.7 kg

Motor Data (at STP)


Motor Type: Standard
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D71
Motor Power: 0.37kW
FLC/Start: 1.02A / 5.20A
Motor Speed: 4 pole
Motor Efficiency:

Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 69 75 74 74 72 69 65 51 81 56
Outlet (dB): 71 75 75 72 70 68 65 56 80 55

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 520.0
DaysPerYear: 366 Annual GH Gas (Tonnes): 4.8
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 1.3
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:06 PM
make changes in design or specification to products without notice.
Page 1 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model AP0404AA10/28

Location: EAF-1F-01A,01B Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:06 PM
make changes in design or specification to products without notice.
Page 2 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model AP0504AA5/33

Location: EAF-1F-02,03 Designation:

Performance - Required Actual


Air Flow : 2000 L/s Air Flow: 2000 L/s
Static Pressure : 100 Pa Static Pressure: 100 Pa
Selection Pressure: 100 Pa Total Pressure: 163 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: AP0504AA5/33 (AP0504AA5B005)
Description: AP Series In-Line Direct Drive

Diameter: 500 mm Hub: 150 mm


Impeller Type: Axial Pitch: 33°
Blade Material: Aluminium Blades: 5
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 0.51 kW Peak: 0.51 kW
Input Power: 0.56 kW
Efficiency Total: 64.2% Static: 39.6%
Fan Weight: 37.0 kg

Motor Data (at STP)


Motor Type: Standard
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D80
Motor Power: 0.55kW
FLC/Start: 1.40A / 7.84A
Motor Speed: 4 pole
Motor Efficiency:

Energy Efficiency, NCC/BCA Vol. 1, Table J5.2 compliant


+ 2006 - 2009
+ 2010 - 2012
+ 2013 - 2016
+ 2015 - 2016 Carpark
Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 76 75 74 74 73 71 66 58 82 57
Outlet (dB): 77 77 73 74 73 70 64 59 83 57

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 773.0
DaysPerYear: 366 Annual GH Gas (Tonnes): 7.1
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 1.9
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 5 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model AP0504AA5/33

Location: EAF-1F-02,03 Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 6 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model AP0504AA10/24

Location: EAF-1F-04 Designation:

Performance - Required Actual


Air Flow : 1600 L/s Air Flow: 1613 L/s
Static Pressure : 150 Pa Static Pressure: 153 Pa
Selection Pressure: 150 Pa Total Pressure: 193 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: AP0504AA10/24 (AP0504AA10B005)
Description: AP Series In-Line Direct Drive

Diameter: 500 mm Hub: 150 mm


Impeller Type: Axial Pitch: 24°
Blade Material: Aluminium Blades: 10
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 0.50 kW Peak: 0.51 kW
Input Power: 0.55 kW
Efficiency Total: 62.2% Static: 49.1%
Fan Weight: 38.2 kg

Motor Data (at STP)


Motor Type: Standard
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D80
Motor Power: 0.55kW
FLC/Start: 1.40A / 7.84A
Motor Speed: 4 pole
Motor Efficiency:

Energy Efficiency, NCC/BCA Vol. 1, Table J5.2 compliant


+ 2006 - 2009
+ 2010 - 2012
+ 2013 - 2016
+ 2015 - 2016 Carpark
Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 75 76 76 78 81 78 76 64 86 64
Outlet (dB): 75 76 78 77 79 76 73 66 85 62

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 773.0
DaysPerYear: 366 Annual GH Gas (Tonnes): 7.1
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 1.9
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 7 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model AP0504AA10/24

Location: EAF-1F-04 Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 8 of 26
EAF-1F-05,06
IMF SERIES
200 250

200
150

10 150

150
0
100 hi
gh

high
100

15
10

0l
0
low

ow
50
50

0 0
0 0.02 0.04 0.06 0.08 0 0.05 0.10 0.15 0.20

200

Technical Data
150
Model
12 Number Free Air FanSpeed Avg. dB(A)
5h IMF... m3/sec rev/sec Watts @ 3m
igh
100 High 0.065 38 27 45
12 100
5 Low 0.057 33 27 41
low
High 0.098 38 34 43
50 125 H
Low 0.082 33 34 38
High 0.163 40 67 48
150
0 Low 0.123 32 67 43
0 0.02 0.04 0.06 0.08 0.10 0.12 High 0.258 41 120 57
200
Low 0.222 38 120 53
High 0.390 40 225 66
250
Low 0.295 30 165 58

250 High 0.612 39 390 69


315
Low 0.486 27 275 61

200
20
0h
igh

150
20
0 lo

100
w

50

0
0 0.05 0.10 0.15 0.20 0.25 0.30

Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication.
Confirmation of dimensions and data will be supplied on request. 3
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model AP0504AA10/15

Location: FAF-1F-01A,01B Designation:

Performance - Required Actual


Air Flow : 1000 L/s Air Flow: 1014 L/s
Static Pressure : 150 Pa Static Pressure: 154 Pa
Selection Pressure: 150 Pa Total Pressure: 170 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: AP0504AA10/15 (AP0504AA10B003)
Description: AP Series In-Line Direct Drive

Diameter: 500 mm Hub: 150 mm


Impeller Type: Axial Pitch: 15°
Blade Material: Aluminium Blades: 10
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 0.29 kW Peak: 0.30 kW
Input Power: 0.40 kW
Efficiency Total: 60.0% Static: 54.3%
Fan Weight: 30.2 kg

Motor Data (at STP)


Motor Type: Standard
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D71
Motor Power: 0.37kW
FLC/Start: 1.02A / 5.20A
Motor Speed: 4 pole
Motor Efficiency:

Energy Efficiency, NCC/BCA Vol. 1, Table J5.2 compliant


+ 2006 - 2009
+ 2010 - 2012
+ 2013 - 2016
+ 2015 - 2016 Carpark
Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 68 80 82 83 81 74 67 56 88 64
Outlet (dB): 76 76 82 82 78 74 70 58 87 63

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 520.0
DaysPerYear: 366 Annual GH Gas (Tonnes): 4.8
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 1.3
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 3 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model AP0504AA10/15

Location: FAF-1F-01A,01B Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 4 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model AP0564AA5/25

Location: FAF-1F-02 Designation:

Performance - Required Actual


Air Flow : 2000 L/s Air Flow: 2017 L/s
Static Pressure : 150 Pa Static Pressure: 152 Pa
Selection Pressure: 150 Pa Total Pressure: 193 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: AP0564AA5/25 (AP0564AA5B005)
Description: AP Series In-Line Direct Drive

Diameter: 560 mm Hub: 150 mm


Impeller Type: Axial Pitch: 25°
Blade Material: Aluminium Blades: 5
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 0.54 kW Peak: 0.54 kW
Input Power: 0.60 kW
Efficiency Total: 71.6% Static: 56.6%
Fan Weight: 40.1 kg

Motor Data (at STP)


Motor Type: Standard
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D80
Motor Power: 0.55kW
FLC/Start: 1.40A / 7.84A
Motor Speed: 4 pole
Motor Efficiency:

Energy Efficiency, NCC/BCA Vol. 1, Table J5.2 compliant


+ 2006 - 2009
+ 2010 - 2012
+ 2013 - 2016
+ 2015 - 2016 Carpark
Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 80 82 86 79 77 76 72 63 89 63
Outlet (dB): 77 78 76 75 79 75 72 67 85 62

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 773.0
DaysPerYear: 366 Annual GH Gas (Tonnes): 7.1
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 1.9
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 9 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model AP0564AA5/25

Location: FAF-1F-02 Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 10 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model AP0404AA10/23

Location: FAF-2F-02 Designation:

Performance - Required Actual


Air Flow : 635 L/s Air Flow: 640 L/s
Static Pressure : 150 Pa Static Pressure: 152 Pa
Selection Pressure: 150 Pa Total Pressure: 168 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: AP0404AA10/23 (AP0404AA10B003)
Description: AP Series In-Line Direct Drive

Diameter: 400 mm Hub: 150 mm


Impeller Type: Axial Pitch: 23°
Blade Material: Aluminium Blades: 10
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 0.19 kW Peak: 0.19 kW
Input Power: 0.29 kW
Efficiency Total: 56.0% Static: 50.8%
Fan Weight: 26.7 kg

Motor Data (at STP)


Motor Type: Standard
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D71
Motor Power: 0.37kW
FLC/Start: 1.02A / 5.20A
Motor Speed: 4 pole
Motor Efficiency:

Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 69 75 74 74 72 69 65 51 81 56
Outlet (dB): 71 75 75 72 70 68 65 56 80 55

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 520.0
DaysPerYear: 366 Annual GH Gas (Tonnes): 4.8
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 1.3
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 15 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model AP0404AA10/23

Location: FAF-2F-02 Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 16 of 26
FAF-1F-03
IMF SERIES
200 250

200
150

10 150

150
0
100 hi
gh

high
100

15
10

0l
0
low

ow
50
50

0 0
0 0.02 0.04 0.06 0.08 0 0.05 0.10 0.15 0.20

200

Technical Data
150
Model
12 Number Free Air FanSpeed Avg. dB(A)
5h IMF... m3/sec rev/sec Watts @ 3m
igh
100 High 0.065 38 27 45
12 100
5 Low 0.057 33 27 41
low
High 0.098 38 34 43
50 125 H
Low 0.082 33 34 38
High 0.163 40 67 48
150
0 Low 0.123 32 67 43
0 0.02 0.04 0.06 0.08 0.10 0.12 High 0.258 41 120 57
200
Low 0.222 38 120 53
High 0.390 40 225 66
250
Low 0.295 30 165 58

250 High 0.612 39 390 69


315
Low 0.486 27 275 61

200
20
0h
igh

150
20
0 lo

100
w

50

0
0 0.05 0.10 0.15 0.20 0.25 0.30

Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication.
Confirmation of dimensions and data will be supplied on request. 3
TEAF-1F-01
IMF SERIES
200 250

200
150

10 150

150
0
100 hi
gh

high
100

15
10

0l
0
low

ow
50
50

0 0
0 0.02 0.04 0.06 0.08 0 0.05 0.10 0.15 0.20

200

Technical Data
150
Model
12 Number Free Air FanSpeed Avg. dB(A)
5h IMF... m3/sec rev/sec Watts @ 3m
igh
100 High 0.065 38 27 45
12 100
5 Low 0.057 33 27 41
low
High 0.098 38 34 43
50 125 H
Low 0.082 33 34 38
High 0.163 40 67 48
150
0 Low 0.123 32 67 43
0 0.02 0.04 0.06 0.08 0.10 0.12 High 0.258 41 120 57
200
Low 0.222 38 120 53
High 0.390 40 225 66
250
Low 0.295 30 165 58

250 High 0.612 39 390 69


315
Low 0.486 27 275 61

200
20
0h
igh

150
20
0 lo

100
w

50

0
0 0.05 0.10 0.15 0.20 0.25 0.30

Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication.
Confirmation of dimensions and data will be supplied on request. 3
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model AP0404AA10/10

Location: EAF-2F-01A,01B Designation:

Performance - Required Actual


Air Flow : 290 L/s Air Flow: 298 L/s
Static Pressure : 150 Pa Static Pressure: 159 Pa
Selection Pressure: 150 Pa Total Pressure: 162 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: AP0404AA10/10 (AP0404AA10B003)
Description: AP Series In-Line Direct Drive

Diameter: 400 mm Hub: 150 mm


Impeller Type: Axial Pitch: 10°
Blade Material: Aluminium Blades: 10
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 0.10 kW Peak: 0.10 kW
Input Power: 0.18 kW
Efficiency Total: 47.4% Static: 46.4%
Fan Weight: 26.7 kg

Motor Data (at STP)


Motor Type: Standard
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D71
Motor Power: 0.37kW
FLC/Start: 1.02A / 5.20A
Motor Speed: 4 pole
Motor Efficiency:

Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 64 75 76 74 72 69 63 49 81 56
Outlet (dB): 73 73 77 72 70 68 64 52 81 55

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 520.0
DaysPerYear: 366 Annual GH Gas (Tonnes): 4.8
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 1.3
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 11 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model AP0404AA10/10

Location: EAF-2F-01A,01B Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 12 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model AP0404AA10/10

Location: FAF-2F-01A;01B Designation:

Performance - Required Actual


Air Flow : 290 L/s Air Flow: 298 L/s
Static Pressure : 150 Pa Static Pressure: 159 Pa
Selection Pressure: 150 Pa Total Pressure: 162 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: AP0404AA10/10 (AP0404AA10B003)
Description: AP Series In-Line Direct Drive

Diameter: 400 mm Hub: 150 mm


Impeller Type: Axial Pitch: 10°
Blade Material: Aluminium Blades: 10
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 0.10 kW Peak: 0.10 kW
Input Power: 0.18 kW
Efficiency Total: 47.4% Static: 46.4%
Fan Weight: 26.7 kg

Motor Data (at STP)


Motor Type: Standard
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D71
Motor Power: 0.37kW
FLC/Start: 1.02A / 5.20A
Motor Speed: 4 pole
Motor Efficiency:

Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 64 75 76 74 72 69 63 49 81 56
Outlet (dB): 73 73 77 72 70 68 64 52 81 55

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 520.0
DaysPerYear: 366 Annual GH Gas (Tonnes): 4.8
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 1.3
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 11 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model AP0404AA10/10

Location: FAF-2F-01A;01B Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 12 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model AP0404AA10/23

Location: FAF-2F-02 Designation:

Performance - Required Actual


Air Flow : 635 L/s Air Flow: 640 L/s
Static Pressure : 150 Pa Static Pressure: 152 Pa
Selection Pressure: 150 Pa Total Pressure: 168 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: AP0404AA10/23 (AP0404AA10B003)
Description: AP Series In-Line Direct Drive

Diameter: 400 mm Hub: 150 mm


Impeller Type: Axial Pitch: 23°
Blade Material: Aluminium Blades: 10
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 0.19 kW Peak: 0.19 kW
Input Power: 0.29 kW
Efficiency Total: 56.0% Static: 50.8%
Fan Weight: 26.7 kg

Motor Data (at STP)


Motor Type: Standard
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D71
Motor Power: 0.37kW
FLC/Start: 1.02A / 5.20A
Motor Speed: 4 pole
Motor Efficiency:

Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 69 75 74 74 72 69 65 51 81 56
Outlet (dB): 71 75 75 72 70 68 65 56 80 55

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 520.0
DaysPerYear: 366 Annual GH Gas (Tonnes): 4.8
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 1.3
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 15 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model AP0404AA10/23

Location: FAF-2F-02 Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 16 of 26
TEAF-2F-01

FANTECH
CBS SERIES
Small Cabinet Fans
 
TECHNICAL DATA 

Static Fan
Power Air Flow Noise
Model Pressure Speed
(W) (m3/h) (dBA @ 3m)
(Pa) (rpm)
CBS200C 220 1200 360 1100 38
CBS200D 320 1500 380 1250 39
CBS250B 400 1900 430 1150 44

DIMENSIONS
 
  FEATURES 
 
ELTAFANTECH’s CBS Series is designed for  
ceiling mounting and is suitable for domestics  
and commercial applications such as houses, office  
premises, bedroom, hotel etc. where require low  
 
noise for small duty and low ceiling height (less than   Dimension in mm
400 mm).
Duct Weight
Construction Model L H W A B I J ØD
size (Kg)
The housing and impeller are made by galvanized CBS200C 650 365 400 478 65 182.5 445 195 Ø 200 21.1
sheet. CBS200D 650 365 400 478 65 182.5 445 195 Ø 200 21.1
Forward inclined impeller wheel with direct driven. CBS250B 740 380 400 548 75 190 445 245 Ø 250 24.1

Motors  
Type – squirrel cage induction motors.   WIRING DIAGRAM 
Electrical supply – 220-240V, single phase,  
 
50/60Hz Bearings – sealed-for-life, ball  
Internal Thermal Protection  
 
Thermal fuse is equipped to cut-out for overload.  
 
How to order  
Select the model that meets your air flow  
and application requirements from the graph.  
 
 
 
     450 
Pressure (Pa) 

 
  400 
 
 

  350 

 
300 
  CBS250B
  250 
 
  200 
CBS200C 
  CBS200D
  150 
 
100 
 
  50 
 
  0 
  0  200  400  600 800 1000 1200 1400 1600  1800  2000
  3 
Air Volume (m /h) 
 
 
 
The specifications may be changed. All rights are reserved by ELTAFANTECH ASIA SDN BHD.
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model AP0404AA10/23

Location: FAF-(3-6)F-01A;01B Designation:

Performance - Required Actual


Air Flow : 635 L/s Air Flow: 640 L/s
Static Pressure : 150 Pa Static Pressure: 152 Pa
Selection Pressure: 150 Pa Total Pressure: 168 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: AP0404AA10/23 (AP0404AA10B003)
Description: AP Series In-Line Direct Drive

Diameter: 400 mm Hub: 150 mm


Impeller Type: Axial Pitch: 23°
Blade Material: Aluminium Blades: 10
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 0.19 kW Peak: 0.19 kW
Input Power: 0.29 kW
Efficiency Total: 56.0% Static: 50.8%
Fan Weight: 26.7 kg

Motor Data (at STP)


Motor Type: Standard
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D71
Motor Power: 0.37kW
FLC/Start: 1.02A / 5.20A
Motor Speed: 4 pole
Motor Efficiency:

Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 69 75 74 74 72 69 65 51 81 56
Outlet (dB): 71 75 75 72 70 68 65 56 80 55

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 520.0
DaysPerYear: 366 Annual GH Gas (Tonnes): 4.8
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 1.3
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 15 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model AP0404AA10/23

Location: FAF-(3-6)F-01A;01B Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 16 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model AP0404AA10/10

Location: EAF-(3-6)F-01A;01B Designation:

Performance - Required Actual


Air Flow : 290 L/s Air Flow: 298 L/s
Static Pressure : 150 Pa Static Pressure: 159 Pa
Selection Pressure: 150 Pa Total Pressure: 162 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: AP0404AA10/10 (AP0404AA10B003)
Description: AP Series In-Line Direct Drive

Diameter: 400 mm Hub: 150 mm


Impeller Type: Axial Pitch: 10°
Blade Material: Aluminium Blades: 10
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 0.10 kW Peak: 0.10 kW
Input Power: 0.18 kW
Efficiency Total: 47.4% Static: 46.4%
Fan Weight: 26.7 kg

Motor Data (at STP)


Motor Type: Standard
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D71
Motor Power: 0.37kW
FLC/Start: 1.02A / 5.20A
Motor Speed: 4 pole
Motor Efficiency:

Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 64 75 76 74 72 69 63 49 81 56
Outlet (dB): 73 73 77 72 70 68 64 52 81 55

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 520.0
DaysPerYear: 366 Annual GH Gas (Tonnes): 4.8
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 1.3
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 19 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model AP0404AA10/10

Location: EAF-(3-6)F-01A;01B Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:07 PM
make changes in design or specification to products without notice.
Page 20 of 26
TEAF-(3-6)F-01
IMF SERIES
200 250

200
150

10 150

150
0
100 hi
gh

high
100

15
10

0l
0
low

ow
50
50

0 0
0 0.02 0.04 0.06 0.08 0 0.05 0.10 0.15 0.20

200

Technical Data
150
Model
12 Number Free Air FanSpeed Avg. dB(A)
5h IMF... m3/sec rev/sec Watts @ 3m
igh
100 High 0.065 38 27 45
12 100
5 Low 0.057 33 27 41
low
High 0.098 38 34 43
50 125 H
Low 0.082 33 34 38
High 0.163 40 67 48
150
0 Low 0.123 32 67 43
0 0.02 0.04 0.06 0.08 0.10 0.12 High 0.258 41 120 57
200
Low 0.222 38 120 53
High 0.390 40 225 66
250
Low 0.295 30 165 58

250 High 0.612 39 390 69


315
Low 0.486 27 275 61

200
20
0h
igh

150
20
0 lo

100
w

50

0
0 0.05 0.10 0.15 0.20 0.25 0.30

Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication.
Confirmation of dimensions and data will be supplied on request. 3
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model APS1004BA14/20

Location: PSAF-RF-01-D Designation:

Performance - Required Actual


Air Flow : 8400 L/s Air Flow: 8544 L/s
Static Pressure : 450 Pa Static Pressure: 466 Pa
Selection Pressure: 450 Pa Total Pressure: 537 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: APS1004BA14/20 (APS1004BA14H075)
Description: APS Series In-Line Smoke Spill

Diameter: 1000 mm Hub: 250 mm


Impeller Type: Axial Pitch: 20°
Blade Material: Aluminium Blades: 14
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 6.94 kW Peak: 7.22 kW
Input Power: 7.59 kW
Efficiency Total: 66.1% Static: 57.3%
Fan Weight: 160.7 kg

Motor Data (at STP)


Motor Type: S/Spill Class H
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D132M
Motor Power: 7.50kW
FLC/Start: 14.30A / 92.95A
Motor Speed: 4 pole
Motor Efficiency:

Energy Efficiency, NCC/BCA Vol. 1, Table J5.2 compliant


+ 2006 - 2009

Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 88 86 98 107 103 98 90 80 109 87
Outlet (dB): 90 86 94 105 104 99 93 84 109 87

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 10540.8
DaysPerYear: 366 Annual GH Gas (Tonnes): 96.6
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 26.3
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:08 PM
make changes in design or specification to products without notice.
Page 23 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model APS1004BA14/20

Location: PSAF-RF-01-D Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:08 PM
make changes in design or specification to products without notice.
Page 24 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model APS0562BA7/26

Location: PSAF-RF-02-D Designation:

Performance - Required Actual


Air Flow : 5200 L/s Air Flow: 5288 L/s
Static Pressure : 400 Pa Static Pressure: 414 Pa
Selection Pressure: 400 Pa Total Pressure: 691 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: APS0562BA7/26 (APS0562BA7H075)
Description: APS Series In-Line Smoke Spill

Diameter: 560 mm Hub: 250 mm


Impeller Type: Axial Pitch: 26°
Blade Material: Aluminium Blades: 7
Speed: 2880 r/min @50 Hz Form: B
Power, Abs: 5.57 kW Peak: 5.85 kW
Input Power: 6.17 kW
Efficiency Total: 65.6% Static: 39.3%
Fan Weight: 107.8 kg

Motor Data (at STP)


Motor Type: S/Spill Class H
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D132S
Motor Power: 7.50kW
FLC/Start: 13.30A / 85.12A
Motor Speed: 2 pole
Motor Efficiency:

Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 95 86 95 96 93 89 87 85 102 77
Outlet (dB): 93 90 94 95 92 90 88 85 101 77

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 10540.8
DaysPerYear: 366 Annual GH Gas (Tonnes): 96.6
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 26.3
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:08 PM
make changes in design or specification to products without notice.
Page 25 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model APS0562BA7/26

Location: PSAF-RF-02-D Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:08 PM
make changes in design or specification to products without notice.
Page 26 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Technical Data - Fan Model APS0562BA7/10

Location: SEAF-RF-01-D Designation:

Performance - Required Actual


Air Flow : 2400 L/s Air Flow: 2532 L/s
Static Pressure : 400 Pa Static Pressure: 445 Pa
Selection Pressure: 400 Pa Total Pressure: 509 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: APS0562BA7/10 (APS0562BA7H030)
Description: APS Series In-Line Smoke Spill

Diameter: 560 mm Hub: 250 mm


Impeller Type: Axial Pitch: 10°
Blade Material: Aluminium Blades: 7
Speed: 2880 r/min @50 Hz Form: B
Power, Abs: 2.22 kW Peak: 2.37 kW
Input Power: 2.51 kW
Efficiency Total: 57.9% Static: 50.7%
Fan Weight: 68.8 kg

Motor Data (at STP)


Motor Type: S/Spill Class H
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D100L
Motor Power: 3.00kW
FLC/Start: 5.70A / 37.62A
Motor Speed: 2 pole
Motor Efficiency:

Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 90 84 93 96 95 91 81 76 101 78
Outlet (dB): 93 95 97 96 94 92 87 81 103 78

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 4216.3
DaysPerYear: 366 Annual GH Gas (Tonnes): 38.7
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 10.5
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:08 PM
make changes in design or specification to products without notice.
Page 21 of 26
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model APS0562BA7/10

Location: SEAF-RF-01-D Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 2/14/2020 2:19:08 PM
make changes in design or specification to products without notice.
Page 22 of 26
GENERAL
CATALOGUE
Duct Mounted.qxd 4/03/2008 3:55 PM Page 31

ADJUSTABLE PITCH AXIAL FLOW FANS

FEATURES ANCILLARY EQUIPMENT


The AP Series of duct mounted adjustable pitch axial flow fans is
available in the following variants:-
O
AP Series - direct-drive
O
APV Series - direct-drive vertical mounted
O
APS Series - direct-drive smoke-spill MF - Matching flange
C..P - Circular silencers Vibration isolators
O
APB Series - belt-drive Ref. H-4/8 Ref. I-1 Ref. J-4
O
BFA Series - bifurcated, direct-drive
Construction
The casings are of mild steel, hot-dip galvanised after
manufacture. Impeller blades shall have an aerofoil section and
be pressure die-cast aluminium, injection-moulded glass-
reinforced plastic or nylon. Anti-static blades for hazardous F - Mounting foot IC - Inlet cone FG - Finger guards
applications up to 1400mm diameter, are also available. Ref. J-6 Ref. J-7 Ref. J-9

Motors
Type - squirrel cage induction motor which can be selected to
suit virtually any specification.
Electricity supply - single or three-phase to suit a wide range of
voltages and frequencies. Inverter
Bearings - ball. Ref. L-9
See pages N-3/4 for details on motors.
Motors to meet Australian Ex e, Ex d, Ex n or D.I.P. Standards
can be fitted. SMOKE-SPILL APPLICATIONS
Internal Thermal Protection The APS Series has been tested to meet the air performance
Can be provided as an optional extra. and high temperature test requirements of Standards
AS/NZS1668.1:1998 and AS/NZS4429:1999; both tests are
Testing mandatory.
Air flow testing:- For advice on smoke-spill wiring requirements refer to the above
315-1000mm diameter - BS848:Part 1, 1980 Standards.
1250-2000mm diameter - ISO5801:1997
See page C-7 for details of the smoke-spill range available.
Noise testing all sizes to BS848:Part 2, 1985

Special Features
Suitable for a wide range of applications, ranging from handling
HOW TO ORDER
ambient filtered air to hot, toxic and noxious gases. -
Hazardous fume applications
AP Series fans can be made to accommodate requirements for AP - direct drive
APV - vertical
corrosive fume and explosion risk applications. Special coatings APS - smoke spill
and alternative materials, such as stainless steel, are available APB - belt drive
as well as increased safety motors and anti-static impellers. Our BFA - bifurcated
sales engineers are able to assist with requirements, which must Fan diameter in cm
be specified at time of quotation. Fan speed, no. of poles
Hub diameter code
Wiring Diagram A =150 D= 400
See pages M-6/7, diagrams DD 1, 2, 3, 7, 8, 9. B = 250 F = 550
C = 350 G = 255
Weights Aluminium blades, A
See pages C-112/113 to determine unit weights. GRP, P
Nylon, N
Dimensions Antistatic blades, E
See pages C-110/111 for dimensions. No. of blades
Blade pitch angle, deg.

© FANTECH 2008 DUCT MOUNTED FANS B-31


Duct Mounted.qxd 4/03/2008 3:55 PM Page 32

AXIAL FLOW FANS QUICK SELECTION GRAPHS


The quick selection curves on these pages are designed to SUGGESTED SPECIFICATION
assist users to determine the fan diameter, speed, approximate
noise level and dimensions of the fan to meet the specified duty. The axial fans shall be of the AP/APV/APS/APB/BFA design(s)
as manufactured by Fantech Pty. Ltd..
Refer to Section C for detailed selection information. All performances shall be based upon BS848:Part 1, 1980 or
Detail including the number of blades and power absorbed is ISO5801:1997 and BS848:Part 2, 1985.
shown on pages C-11/109 or is available from the Fantech CD
program. Casings shall be hot-dip galvanised mild steel. Impellers shall
be of aerofoil section glass-reinforced plastic (GRP), nylon, or
B Pages C-2/8 provide detailed information on these products.
An example of how to use the curves is shown on page C-9.
aluminium; GRP is standard where selection permits.

The dimensions for all fans are on pages C-110/111.


Weights can be determined from details on pages C-112/113.

Model Numbers
O
AP - direct-driven; 315 to 2000mm diameter
O
APV - direct-driven; 315 to 2000mm diameter
O
APS - direct-driven; 315 to 2000mm diameter
O
APB - belt driven; 315 to 2000mm diameter
O
BFA - bifurcated; 400 to 1250mm diameter

2 Pole
3000 48 rev/sec
2000
95
91
1000 88
80 92
80 92
pSF - Fan Static Pressure, Pa

600 90
71 75
78 0802
400 65 0712
70 0632
0502 0562
200 0312 65 0402
em
st s
Sy ine
L
100

60 68 71 80 78 94 95 91

0.2 0.4 0.6 1.0 2.0 4.0 6.0 10.0 20.0 30.0
qV - Volume Flow, m /s3
dB(A) @ 3m: Inlet Side =

4 Pole
2000 24 rev/sec
92
87
1000
90
600 83 85
pSF - Fan Static Pressure, Pa

Lin stem

69 78
400
es

75
Sy

73 69
68 71
68
200 65 1254 1404
64 0804 1004
63 0634 0714
0564
56 52 0504
100 51 49 0404
0314 49 55 64 67 71 73 73 78 88 93
60
0.2 0.4 0.6 1.0 2.0 4.0 6.0 10.0 20.0 40.0 60.0
qV - Volume Flow, m /s
3
dB(A) @ 3m: Inlet Side =

B-32 DUCT MOUNTED FANS © FANTECH 2008


Duct Mounted.qxd 4/03/2008 3:55 PM Page 33

AXIAL FLOW FANS QUICK SELECTION GRAPHS

6 Pole
1000 96 16 rev/sec
86 90
82
600
78 95
400 88
81
Lin tem

80
pSF - Fan Static Pressure, Pa

B
es
s

72 75
Sy

200 63 67

66 59 1606 1806 2006


62 1406
63 1256
59 58 1006
100 54 0806
0716
56 56 0636
0566
60 48 0506
0406 45 51 57 61 67 65 70 76 81 83 88 92
0316 40
40
0.2 0.4 0.6 1.0 2.0 4.0 6.0 10.0 20.0 40.0 60.0 100.0
qV - Volume Flow, m /s
3
dB(A) @ 3m: Inlet Side =

8 Pole
600 12 rev/sec
86
400 78 82
74 77
72 74
71
Lin tem
pSF - Fan Static Pressure, Pa

71
200
es
s
Sy

63 61

1258 1408 1608 1808 2008


57 60
100 1008
58 58 0808
56 51 0718
60 0638
51 59 62 62 71 75 75 79 83
40
0.6 1.0 2.0 4.0 6.0 10.0 20.0 40.0 60.0 100.0
qV - Volume Flow, m /s 3
dB(A) @ 3m: Inlet Side =

10 Pole
400 10 rev/sec
81
78
78
72 75
70
200
pSF - Fan Static Pressure, Pa

em 1601 1801 2001


st s
Sy ine
100 L

60 71 75 78

50
6.0 10.0 20.0 40.0 60.0 80.0
qV - Volume Flow, m /s
3
dB(A) @ 3m: Inlet Side =

© FANTECH 2008 DUCT MOUNTED FANS B-33


IMF
In-line Mixed Flow Fan
IMF SERIES How To Order IMF

IMF - IMF Series


100 to 315 - Fan size

100, 125, 150 & 200 Models


Motor
Type - 2 speed, induction.
Electricity supply - single phase 220-240V 50hz or 220V 60Hz.
Bearings - ball.
Maximum ambient temperature - 50℃.
Class II insulation, IPX4 rated.

Internal Thermal Protection


Model 100, 125, 150 and 200 - one shot thermal fuse.

Testing

Description Airflow to ISO 5801:2007


Noise to BS 848 Part 2:1985
The IMF Series are a range of in-line mixed flow fans with
a compact profile. This means they offer excellent pressure
development characteristics. They have been designed specifically
Suggested Specification
for use with rigid or flexible ductwork and can be used for a wide The in-line fans shall be of the IMF Series as supplied by Elta Fans
variety of residential and commercial applications. Available in 6 and be of the models shown. It shall have single-phase induction
sizes to suit 100, 125, 150, 200, 250 and 315mm duct. motor with built in thermal protection and double insulated so no
earth connection is required. Fan housing and impeller are made
Typical Applications from high quality plastic. Motors and impellers are balanced to
ISO 14694 Grade G6.3. All models shall be fully tested to ISO
Exhaust from bathrooms, toilets, laundries, kitchens and other
5801:2007 for Airflow and BS848 Part 2:1985 for noise.
small to medium spaces in houses, hotels and apartments.

Features 250 & 350 Models


• All plastic casing provides a long lasting, robust and
non-corrosive construction. Motor
• Unique mixed flow impeller with fixed blade angles designed to
Type - 2 speed, induction.
overcome the resistances of long ducting systems and creates Electricity supply - single phase 230V 50Hz.
top silent operation. Bearings - ball.
• Units have been constructed from shockproof, heat resistant Maximum ambient temperature - 50℃.
white plastic, with both motor and impeller mounted within the Class F insulation, IP44 rated.
unit casing.
Internal Thermal Protection
• Single-phase induction motor with integral thermal protection,
mounted on sealed for life high quality sleeve bearings. Model 250, 315 - auto-reset integral thermal protection.
• Wired terminal box mounted on the outside of the unit casing,
Testing
for ease of connection
Data accurate to suspension free air test at 3m, contact your local
• Double insulated so no earth connection is required. Available
office for more information.
in Standard and run-on timer versions.
• Suitable for continuous and intermittent running.
• Comes with 2 year warranty.
• Mounting bracket is supplied as standard.

Construction
Fan housing and impeller are made from high quality plastic which
is shock proof and long lasting.
Finished in white RAL 9010 and UV resistant.

Ancillary Equipment

Ceiling Grilles Ducting, Louvres & Grilles


Ref. Section L Ref. Section L

2 Tel +603 7846 0340 Fax +603 7842 1132 Email info@eltafans.asia Website eltafans.asia
IMF SERIES
200 250

200
150

10 150

150
0
100 hi
gh

high
100

15
10

0l
0
low

ow
50
50

0 0
0 0.02 0.04 0.06 0.08 0 0.05 0.10 0.15 0.20

200

Technical Data
150
Model
12 Number Free Air FanSpeed Avg. dB(A)
5h IMF... m3/sec rev/sec Watts @ 3m
igh
100 High 0.065 38 27 45
12 100
5 Low 0.057 33 27 41
low
High 0.098 38 34 43
50 125 H
Low 0.082 33 34 38
High 0.163 40 67 48
150
0 Low 0.123 32 67 43
0 0.02 0.04 0.06 0.08 0.10 0.12 High 0.258 41 120 57
200
Low 0.222 38 120 53
High 0.390 40 225 66
250
Low 0.295 30 165 58

250 High 0.612 39 390 69


315
Low 0.486 27 275 61

200
20
0h
igh

150
20
0 lo

100
w

50

0
0 0.05 0.10 0.15 0.20 0.25 0.30

Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication.
Confirmation of dimensions and data will be supplied on request. 3
Dimensions

Model
100, 125, 150 & 200
Number Dimensions, mm
1800 IMF... A B CØ D E F G H I
100 140 296 97 154 - 179 202 217 190
C D H I
125 140 256 124 154 - 179 202 215 190
150 182 298 147 170 - 194 223 236 211
200 120 314 197 236 - 254 272 271 236
250 150 384 246 261 150 310 286 - -
A F
B G 315 181 446 311 325 178 386 357 - -

250 & 315



A E
B F

Elta Fans Malaysia Sdn Bhd


Tel +603 7846 0340
Fax +603 7842 1132
Email info@eltafans.asia

No. 147, Jalan TUDM Kampung


Baru Subang, 40150 Shah Alam,
Selangor West Malaysia, Malaysia

eltafans.asia

IMF-08-2019 Issue A

FS 676456
FANTECH
CBS SERIES
Small Cabinet Fans
 
TECHNICAL DATA 

Static Fan
Power Air Flow Noise
Model Pressure Speed
(W) (m3/h) (dBA @ 3m)
(Pa) (rpm)
CBS200C 220 1200 360 1100 38
CBS200D 320 1500 380 1250 39
CBS250B 400 1900 430 1150 44

DIMENSIONS
 
  FEATURES 
 
ELTAFANTECH’s CBS Series is designed for  
ceiling mounting and is suitable for domestics  
and commercial applications such as houses, office  
premises, bedroom, hotel etc. where require low  
 
noise for small duty and low ceiling height (less than   Dimension in mm
400 mm).
Duct Weight
Construction Model L H W A B I J ØD
size (Kg)
The housing and impeller are made by galvanized CBS200C 650 365 400 478 65 182.5 445 195 Ø 200 21.1
sheet. CBS200D 650 365 400 478 65 182.5 445 195 Ø 200 21.1
Forward inclined impeller wheel with direct driven. CBS250B 740 380 400 548 75 190 445 245 Ø 250 24.1

Motors  
Type – squirrel cage induction motors.   WIRING DIAGRAM 
Electrical supply – 220-240V, single phase,  
 
50/60Hz Bearings – sealed-for-life, ball  
Internal Thermal Protection  
 
Thermal fuse is equipped to cut-out for overload.  
 
How to order  
Select the model that meets your air flow  
and application requirements from the graph.  
 
 
 
     450 
Pressure (Pa) 

 
  400 
 
 

  350 

 
300 
  CBS250B
  250 
 
  200 
CBS200C 
  CBS200D
  150 
 
100 
 
  50 
 
  0 
  0  200  400  600 800 1000 1200 1400 1600  1800  2000
  3 
Air Volume (m /h) 
 
 
 
The specifications may be changed. All rights are reserved by ELTAFANTECH ASIA SDN BHD.

S-ar putea să vă placă și