Documente Academic
Documente Profesional
Documente Cultură
1
DUAL METAL BELLOWS CARTRIDGE SEAL
Installation, Operation & Maintenance Instructions
Safety Instructions
1. The following designations are used in the installation instructions to 5. If the pumped fluid is hazardous or toxic, appropriate precautions
highlight instructions of particular importance. must be taken to ensure that any seal leakage is adequately
contained. Further information on sealing hazardous or toxic fluids
NOTE: Refers to special information on how to install or
should be obtained from John Crane prior to seal installation.
operate the seal most efficiently.
6. Fluorocarbon components should never be burned or incinerated
ATTENTION Refers to special information or instructions directed
as the fumes and residues are highly toxic. If fluorocarbons are
towards the prevention of damage to the seal or its
accidentally heated above 400˚C/750˚F, they can decompose.
surroundings.
Protective gloves should be worn as hydrofluoric acid may be present.
Refers to mandatory instructions designed to
7. PTFE components should never be burned or incinerated as the
! prevent personal injury or extensive damage to the
fumes are highly toxic.
seal or its surroundings.
2. Installation, removal and maintenance of the seal must be carried out
only by qualified personnel who have read and understood these
installation instructions.
3. The seal is designed exclusively for sealing rotating shafts. The
manufacturer cannot be held liable for use of the seal for purposes
other than this.
4. The seal must only be used in technically perfect condition and
must be operated within the recommended performance limits in
accordance with its designated use set out in these installation
instructions.
Typical Type 5625 Dual Metal Bellows Cartridge Typical Type 5625P (Pumping Ring) Dual Metal Bellows
Seal Arrangement Cartridge Seal Arrangement
15 15
14 11 14 11
12 12
9 9
10 10
7 7
6 5 13 17 18 2 1 3 4 8 16 6 5 13 17 18 2 1 3 4 8 16
DIAL INDICATOR
0.040" Rotating Seal Head ON SHAFT
- 0.002" FIM max.
63
20˚
BORE
0D +0.000" TURN SHAFT BY HAND AND NOTE
SHAFT OR SLEEVE
MEASUREMENT ON DIAL INDICATOR
- 0.002" 0.040 LG. X 20˚ CHAM.
NOTE: If measured dimensions exceed those values given, correct the equipment to meet specifications prior to seal installation.
TYPE 5625/5625P PAGE
3
DUAL METAL BELLOWS CARTRIDGE SEAL
Installation, Operation & Maintenance Instructions
Type 5625 Dual Metal Bellows Cartridge Seal Assembly
Assemble the Type 5625 or 5625P as follows, referring to the applicable 6. Set the gland plate assembly gasket side down on table. Install collar on
engineering layout drawing. gland plate assembly and engage spacers into groove, aligning spacers
with pipe taps of gland plate. Uniformly finger tighten the cap screws.
NOTE: These instructions apply to a rotating mating ring configuration.
This sets the radial spacing of the cartridge.
The seal assembly and mating ring positions could be reversed
should an application require. 7. Install lubricated O-ring into outside diameter (OD) groove of seal
assembly rear adapter.
NOTE: Elastomeric O-rings can be damaged or destroyed if care is not
taken. Prior to assembly of O-ring into groove, make sure groove 8. Insert seal head assembly in gland plate adapter, align pins and press
is clean and free of foreign materials. Lubricate both groove and in place.
O-ring prior to installation with light lube oil (SAE #10 or #20) or 9. Clean faces of primary and mating rings with denatured alcohol and a
silicone grease (such as Dow Corning compound #4.) For ethylene lint-free cloth.
propylene elastomers, do not lubricate with petroleum products.
10. Stand sleeve on its base and slide seal assembly over sleeve until seal
1. Place gland plate on table with gasket side facing up. faces touch.
2. Install lubricated O-ring into outside diameter (OD) groove of mating 11. Install lubricated O-ring into ID groove of sleeve adapter.*
ring. 12. Slide sleeve adapter over sleeve, aligning pins of adapter with pins of
3. Stand sleeve on its base and slide mating ring over sleeve, align pins sleeve. Push down to engage drive flats until adapter stops at step of
and press in place. sleeve.
4. Install set screws in collar. 13. Carefully slide snap ring over the end of sleeve. Using assembly tool,
5. Loosely attach the spacers to the collar with cap screws. push the snap ring in place inside the sleeve adapter until it snaps in
Typical Type 5625 Installation Dimensions Typical Type 5625P Installation Dimensions
M SLOT
WIDTH M SLOT
WIDTH
N
L90 MIN. NEAREST OBSTRUCTION N
L91 MIN. BOX DEPTH L39 L90 MIN. NEAREST OBSTRUCTION
L23 L91 MIN. BOX DEPTH L39
L56 L23
L56
L92
D26 L92
D26
*MIN.
TURN *MIN.
DIAM. TURN
DIAM.
D4
D4
D3 c
D3
L12
D1 L12
D1
Type 5625/5625P Dual Cartridge Type 5625/5625P Oversize Bore Dual Cartridge
Dimensional Data (inches) Dimensional Data (inches)
Seal D4 Seal D4 Min.
Size/D1 D3 Min. Max. D26 L12 L23 L39 L56 L90 L91 L92 M N Size/D1 D3 Min. Max. D26 L12 L23 L39 L56 L90 L91 L92 M N Turn Diam.
1.000 1.564 1.625 1.889 4.000 3.705 1.353 1.954 0.531 2.000 1.876 1.751 0.525 2.805 1.375 1.939 2.875 3.023 5.375 3.851 1.446 2.062 0.625 2.125 1.914 1.789 0.562 4.062 3.268
1.125 1.689 1.750 2.015 4.125 3.851 1.446 2.062 0.531 2.125 1.914 1.789 0.525 2.933 1.750 2.420 3.500 3.925 6.500 3.995 1.487 2.125 0.656 2.187 1.995 1.870 0.687 5.093 3.885
1.250 1.812 1.875 2.294 4.250 3.851 1.446 2.062 0.531 2.125 1.914 1.789 0.525 3.213 1.875 2.562 3.625 3.734 6.500 3.995 1.487 2.125 0.656 2.187 1.995 1.870 0.687 5.093 4.006
1.375 1.939 2.000 2.421 4.375 3.851 1.446 2.062 0.531 2.125 1.914 1.789 0.525 3.338 2.125 2.798 3.875 4.250 7.156 4.355 1.570 2.282 0.749 2.407 2.198 2.073 0.687 5.687 4.264
1.500 2.187 2.250 2.680 4.875 3.995 1.487 2.125 0.593 2.187 1.995 1.870 0.525 3.599 2.500 3.312 4.750 4.875 8.000 4.545 1.697 2.407 0.656 2.532 2.263 2.138 0.687 6.062 5.139
1.625 2.312 2.375 2.812 5.000 3.995 1.487 2.125 0.593 2.187 1.995 1.870 0.562 3.766 2.625 3.562 4.625 4.740 8.000 4.594 1.788 2.500 0.749 2.562 2.219 2.094 0.687 6.062 5.000
1.750 2.420 2.480 2.918 5.250 3.995 1.487 2.125 0.593 2.187 1.995 1.870 0.562 3.875 2.750 3.551 4.750 4.875 8.000 4.594 1.697 2.407 0.656 2.532 2.312 2.187 0.687 6.062 5.139
1.875 2.562 2.625 2.918 5.250 3.995 1.487 2.125 0.593 2.187 1.995 1.870 0.562 3.875
2.000 2.687 2.750 3.015 5.500 4.355 1.601 2.312 1.063 2.375 2.167 2.042 0.562 4.000
2.125 2.812 2.875 3.360 5.859 4.355 1.601 2.312 0.593 2.375 2.167 2.042 0.687 4.469
2.250 2.937 3.000 3.485 6.500 4.355 1.601 2.312 0.593 2.375 2.167 2.042 0.687 4.566
2.375 3.062 3.125 3.610 6.500 4.545 1.717 2.466 0.625 2.528 2.204 2.079 0.687 4.719
2.500 3.312 3.375 3.891 6.750 4.545 1.717 2.563 0.625 2.625 2.107 1.982 0.687 5.000
2.625 3.562 3.625 4.062 6.750 4.594 1.625 2.500 0.625 2.562 2.219 2.094 0.687 5.170
2.750 3.562 3.625 4.062 6.750 4.594 1.625 2.500 0.625 2.562 2.219 2.094 0.687 5.170
2.875 3.687 3.750 4.186 7.000 4.594 1.725 2.500 0.625 2.562 2.219 2.094 0.687 5.312
3.000 3.937 4.000 4.469 7.750 4.594 1.787 2.562 0.685 2.625 2.157 2.032 0.812 5.720
CAP
SCREWS
SPACERS
Option #1 requires
Direction of view is from manual venting of
the driver end of pump. entrapped air through
port #1 prior to start-up. Drain (Plugged)
Drain (Plugged)
Operating Limits
Pressure: Operating: Up to 300 psig / 21 barg
Static: Up to 450 psig / 31 barg
Inboard seal ID/Reverse: Up to 150 psig / 10 barg
Temperature: -20˚F to 400˚F / -29˚C to 204˚C
Speed: Up to 5000 fpm / 25 mps
North America Europe Latin America Middle East & Africa Asia Pacific
United States of America United Kingdom Brazil United Arab Emirates Singapore
Tel: 1-847-967-2400 Tel: 44-1753-224000 Tel: 55-11-3371-2500 Tel: 971-481-27800 Tel: 65-6518-1800
Fax: 1-847-967-3915 Fax: 44-1753-224224 Fax: 55-11-3371-2599 Fax: 971-488-62830 Fax: 65-6518-1803
If the products featured will be used in a potentially dangerous and/or hazardous process, your John Crane representative should be consulted prior to
their selection and use. In the interest of continuous development, John Crane Companies reserve the right to alter designs and specifications without
prior notice. It is dangerous to smoke while handling products made from PTFE. Old and new PTFE products must not be incinerated. ISO 9001 and
ISO14001 Certified, details available on request.
©2015 John Crane Revised 10/15 www.johncrane.com IOM-5625/5625P