04-23-2014, 12:54 PM #1

hdts
relay ext dc voltage missing
Registered
Join Date: Apr 2014 hi,
Posts: 2 Seem to have this very classic problem, brought a Bridgeport interact 300
TNC 2500 its been working very lightly for a couple of weeks and then ( relay
ext dc voltage missing ) thats all i get when i turn it on and i cant get past
that.
e-stop is pulled out and when you press the main power button there is a
distinctive clunk.
oil level ok
new batteries in
checked main power supply ok
checked fuses that i can see
machine in the middle of table and checked limit switches not jammed so ok

i'm not the most competent electrician but pushed the e-stop in and got 24v
across it and all the limit switches, door interlocks when key out also when i
look in the cabinet 2CR is energized.

when the fault first happened the machine did come back to life briefly but
now nothing i do have the original schematic but as i said before not the most
competent.

so really not sure where else to look


any help would be greatly appreciated
thanks
hdts
https://en.industryarena.com/forum/relay-ext-dc-voltage-missing--219610.html 1/4
2020/4/28 Bridgeport / Hardinge Mills > relay ext dc voltage missing

 
Reply With Quote

04-25-2014, 11:38 PM #2

gus
Re: relay ext dc voltage missing
Registered
Join Date: Jan 2005 check the emo string
Posts: 1093
oil level
limit switches
etc
do you have a schematic?

does the relay hold? IOW if you release the enable button does the relay fall
out[and clunk again when you press again?

that would indicate a overtravel or oil or whatever switch error

Reply With Quote

04-27-2014, 08:17 PM #3

hdts
Re: relay ext dc voltage missing
Registered
Join Date: Apr 2014 Thanks for replying Gus, since i posted my problem i have check all limit
Posts: 2 switches emo string oil by going into the control and watching them go on and
off when pressing and also checking the continuity of everything on the 24v
schematic that i have ( limit switch, door locks, thermostats, oil level, e-stop).
also all fuses cabinet and in the TNC, starting to run out of things to check and
still the machine does not work.
Any suggestions
hdts

Reply With Quote

04-29-2014, 12:29 PM #4

gus
Re: relay ext dc voltage missing
Registered

https://en.industryarena.com/forum/relay-ext-dc-voltage-missing--219610.html 2/4
2020/4/28 Bridgeport / Hardinge Mills > relay ext dc voltage missing


Join Date:
Posts:
Jan 2005
1093
well could be 24v supply, or ISTR someone having the actual input on the
control go bad., sochase that end of the wiring,where the closing of the relay
is confrmed to the control[IOW all the switches have 24v, bu tit dos not get

back to the control

Reply With Quote

01-02-2015, 12:22 PM #5

raimundelis Good day,


Junior Member
Join Date: Dec 2014 I am new on this forum. Hope, I will find help here.
Posts: 1 I have Bridgeport interact1 MK2 TNC 155. Now I have problem with "relay ext
dc voltage missing". I checked everything: oil level, all safety and limit
switches, 24V DC regulator etc. Machine has stopped in milling process and
this message appeared. Does anyone tried to check main controller's PCBs?
Maybe problem is there? I have 24v on 65 wire (J1/10) but there is no voltage
on 59 wire (J1/8) where it has to be to open DC interlock relay (10CR). Please
help.
Best regards,
Raimondas

Reply With Quote

Quick Navigation Bridgeport / Hardinge Mills Top

« Previous Thread | Next Thread »

Similar Threads

BT Interact 412 - RELAY EXT. DC VOLTAGE MISSING Replies: 14


By Zhales in forum Bridgeport / Hardinge Mills Last Post: 10-19-2017, 03:19 PM

relay ext. dc voltage missing error on tnc 150 B Replies: 2


By M535 in forum Bridgeport / Hardinge Mills Last Post: 05-07-2013, 12:20 PM

relay ext dc voltage missing in TNC 351 Replies: 2


By moghul in forum Bridgeport / Hardinge Mills Last Post: 01-29-2013, 02:03 AM

Relay ext, dc voltage missing Replies: 16


By fastcarl in forum Bridgeport / Hardinge Mills Last Post: 11-18-2010, 01:57 PM

https://en.industryarena.com/forum/relay-ext-dc-voltage-missing--219610.html 3/4
2020/4/28 Bridgeport / Hardinge Mills > relay ext dc voltage missing

 Help..Stuck at relay ext dc voltage missing but dc voltage OK ?


By Dirky in forum Bridgeport / Hardinge Mills

Tags for this Thread



Replies: 24
Last Post: 11-27-2007, 02:33 PM

24v, bat, bridgeport, couple, door, fault, fuses, interact, level, limit, limit switches, missing, power,
power supply, press, problem, relay, schematic, stop, supply, swi, table, tnc, turn, voltage
View Tag Cloud

Posting Permissions

You may not post new BB code is On


threads Smilies are On
You may not post replies [IMG] code is On
You may not post [VIDEO] code is On
attachments HTML code is Off
You may not edit your posts
Forum Rules

All times are GMT +1. The time now is 05:13 AM.
Powered by vBulletin® Version 4.2.5
Copyright © 2020 vBulletin Solutions Inc. All rights reserved.

IMPRINT
CONTACT
PRIVACY POLICY
RULES
DISCLAIMER

https://en.industryarena.com/forum/relay-ext-dc-voltage-missing--219610.html 4/4

S-ar putea să vă placă și