Sunteți pe pagina 1din 2

Roll No- SET-B

Environmental Engineering-II
TE (Civil)
Mid-Term Test
Date- 3/3/2012 Max. Marks – 50
Time – 9 am to 10.30 am Min. marks -20
Instructions: - 1) All questions are compulsory in Q no. 1.
2) Solve any three questions from Q no.2 to Q no. 5.
3) Assume suitable data whenever required.
4) Figure to the right indicates full marks.

Q1. Rewrite the statement by filling in the blank with correct option. (10 marks)
1. Pick out the odd one - _________.
a) Screen chamber b) Grit chamber
c) PST d) Septic tank
4. For population above 100000, density of population per hectare is ________.
a) 75-100 b) 150-250
c) 350-1000 d) None ofthese.
7. Trickling filter is ________________ process.
a) Suspended growth b) Suppressed growth
c) Floating growth d) Settled growth
10. For population below 2 lacs, sewage production rate in lpcd is ______.
a) 130-160 b) 110-120
c) 60-90 d) 150-170
13. For contributory population of 20000, peak factor is _______.
a) 3.5 b) 2.5
c) 2 d) 2.25
16. In Trickling filter ______________ is recycled to aeration tank
a) sludge b) sewage
c) Both d) None of above
19. Mannings N for good cast iron interior surface is ______.
a) 0.012 b) 0.014
c) 0.011 d) All of above
22. In COD test, ____________________ is used as oxidizing agent.
a) Potassium dichromate b) Sulphuric acid
c) Mercuric sulphate d) None of these
25. Length of grit chamber shall be in the range of _______________
a) 10 to 18 b) 2 to 5
c) 15 to 20 d) More than 20
Roll No- SET-B
28. Unit of SVI is ____________.
a) ml/gm b) mm/gm
c) Lit/kg d) None of above
Q 2] a) Compare between conservancy system and water carriage system. (7)

b) A stone ware sewer, 30 cm in diameter is laid at a gradient of 1:100. (6)


Using N=0.013 calculate velocity, discharge and Chezy’s coefficient
when sewer is running full.
Q 3] a) During a BOD test 5 ml waste saple is diluted in BOD bottle. Following (6)
readings are taken:
Initial DO=7.8
Final DO= 3.2
Find i. Standard BOD and ii. Ultimate BOD if k=0.23 /day
c) Draw neat sketch of trickling filter. Write NRC equation for SRTF (7)
Q4] a) Draw a flow sheet of domestic wastewater treatment plant consisting of (4)
ASP.
b) Design ASP for following data: Population = 120000 (9)
Sewage flow= 160 lpcd
Settled sewage BOD = 200 mg/lit
Effluent BOD = 15 mg/lit
Assume necessary data such as F/m, Xt etc.
Q5] Write short notes (Any two) (14)
1. Pumping station.
2. NRC equation for HRTF
3. Necessity of Wastewater treatment