Sunteți pe pagina 1din 4

Saitel IEC 61850 Client

and Server
Efficient Substation Automation with IEC 61850 Standard

Make the most of your energy SM


Saitel IEC 61850 Client and Server

The IEC 61850 standard is the result after years of work by


electric utilities and vendors of electronic equipment to create
a uniform, future-proof basis for the protection, control and
communication of substations.

Today, the IEC 61850 Standard provides an internationally recognized method


targeted at interoperability between IEDs from different vendors.

IEC 61850 goes far beyond just a protocol standard by defining a


comprehensive device and object model that uses simple names in a
power system context. IEC 61850 provides a standardized framework for
substation integration specifying the communications requirements, functional
characteristics, structure of data in devices, data naming conventions, how
applications interact and control devices and how conformity with the standard
should be tested. These models are then mapped to a specific set of protocol
profiles that are optimised and secure for each functional area of the system.

This new technology can improve your substation systems by lowering your
costs, improving power reliability or both. IEC 61850 has a proven track record
of deliverable benefits to both small and large utilities. IEC 61850 offers the
ability to implement new capabilities and deliver cost savings in substation
design, installation, commissioning and operation.

Saitel compliance with IEC 61850


Saitel is a highly-evolved field device, offering a solid and powerful platform for
data acquisition, communication, automation and IED integration, including
backplane and DIN rail based solutions.

Saitel RTUs offer both IEC 61850 client and server functionality. Therefore
Saitel is the ideal solution for several applications:
• As a gateway to interface the IEC 61850 station bus through a variety of
modern plus third party communication protocols with different control
centres.

This new technology can improve your


substation systems by lowering your costs,
improving power reliability or both.

02 | Saitel IEC 61850 Client and Server


• As a Bay Control Unit for control and monitoring • Reporting Schemes
of switchgear, transformers and other equipment - Buffered Report Control Block (BRCB)
or devices in substations. - Unbuffered Report Control Block (URCB)
• Integrate existing inputs and outputs into the IEC • Commands
61850 station bus. - Direct Control
• Connect serial IEDs to the IEC 61850 - Enhanced direct control
station bus. - SBO control
• Support GOOSE for high-speed data exchange - Enhanced SBO control
with other IEC 61850 devices. • Data Sets
• Data logging
Schneider Electric offers you IEC 61850 • Time synchronization via SNTP
technology that is certified as Class A • File Transfer via MMS and FTP
by the independent testing laboratory KEMA for • Configuration
both IEC 61850 server and client interfaces. - Data model designed using SCL-Tool.
- The resulting SCL file is loaded
Schneider Electric is the first company ever to
pass a KEMA IEC-61850 Client certification The engineering tool – SCL Tool
according to Conformance Test Procedures for Schneider Electric CAT SCL Tool is a desktop
Client System with IEC-61850-8-1 interface. application for PC platforms designed to model
intelligent electronic devices (IEDs) as stipulated in
These certifications are another Schneider Electric the standard IEC61850. SCL Tool can generate the
technological landmark in more than 30 years configuration files for these devices.
offering real-time applications for efficient electric
energy business. The main functions that the application can
perform are:
Specifications • Read and edit any type of configuration file
• Supports up to 75 IEDs compliant with the defined restrictions by the
• Client and Server roles schema of the SCL language.
• SCSMs supported • Model devices from the libraries of Logical Nodes
- SCSM: IEC 61850 8.1 (MMS) used (LNs), Common Data Class (CDCs) and Common
• Generic substation event model (GSE) Data Attributes (CDAs) defined in the norm.
- GOOSE Publisher / Subscriber • Generation of the modelling and SCL
• Data Modeling configuration files for devices IEC61850.
- IEC-61850 Logical Nodes Ed.2
- Logical Nodes for Hydro Power Plants

Saitel IEC 61850 Client and Server | 03


• Capacity to manage projects with several
devices, generating the files for the configured
devices.
• Visualization and edition of the components of
the standard library of the norm. This can be
customized with user additions or generate
custom libraries for specific projects.
• Export files of data templates
(DataTypeTemplates) that can be reused to model
new devices. This avoids the need to create all
these sections in new models.

Project References
• Spain. Gatica Substation, 220/132kV. Red
Eléctrica Española. Spain.
• Terranova, Quevedo and Sicle. Comisión Federal
de la Electricidad de México.
• 22 HV/MV substations. EMCALI. Columbia.
• TKCSA. Companhia Siderúrgica do Atlántico.
Brazil.
• 2 Substations. Petroproducción. Ecuador.
• Vizcarra Substation. Abengoa Perú.
• Sao Paulo (Abengoa): Substation Gateways
• 3 HV SE Oriximiná, SE Silves e SE Lechuga.
Manaus Transmissora de Energia.
• Substation Control Unit. Gas Natural Fenosa.
• PARK 61850 project. Red Eléctrica de España

©2012 Schneider Electric. All rights reserved.

Schneider Electric Industries SAS


Campus Palmas Altas Parcela ZE-3,
Palmas Altas 41014 Seville, Spain
Phone: (34) 91-714-70-02
Fax: (34) 954-926-424
www.schneider-electric.com

August 2012

S-ar putea să vă placă și