Required permiability of drainage Layer

Combined Thickness of the slab & DLC Layer H 450
The drainage layer will be provided below the DLC layer at the depth
450 mm from pavement surface. The drainage layer will be extended
to the full width of embankment          AB 10.4
REQUIRED  K=319
Horizontal Camber 0.025 12.48 mtr
Longitudinal Slope 0.03 A 3.0% C
Length of water to be traveled (Longitudinaly) in the same tme, i.e.
take for traveling horizontal distance          AC 12.48
Distance travelled in diagonaly (Actual Path)          AD 16.25

mtr
10.4 m
16
.25
  m
Drop of elevation in longitudinal direction Along         AC 0.374 tr
Drop of elevation inhorizontal direction Along         AB 0.260
Drop of elevation in diagonal direction Along         AD 0.634 2.5%
Gradient along diagonal I 0.039
Crack infiltration rate Ic 0.223
Number of longitudinal Joints Nc 3
Width of pavement subjected to infiltration Wp 9.5 B D
Length of transverse cracks and  joints Wc 8.5
Spacing of transverse joint Cs 4.5
Rate of infiltration through un‐cracked pavement surface Kp 0
Thus the rate of infiltraion of water into pavement qi 0.115
Amount of Infiltrated waterper meter width along diagonal Q 1.868
Area of Drainage Layeralong Diagonal per meter width  A 0.15
Permiability         k                                                        REQUIRED K 319