Documente Academic
Documente Profesional
Documente Cultură
Power
Power - hp
90
60
30
200
180
160
140 10.50 in 63 70 75
120 79
Head - psi
10.40 in 82
100 83
82
79
80 75
60 8.25 in 70
63
40
20
0
0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000
Flow - USgpm
90 Power
Power - hp
60
30
200
180
160
140
10.50 in
63 70
75
120 79
Head - psi
10.40 in 82
100 83
82
79
80 75
8.25 in
60 70
63
40
20
0
0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000
Flow - USgpm
Customer : Peerless Model : 5AEF11
Customer ref. / PO : Stages :1
Tag Number Speed, rated : 2800 rpm
Service : Based on curve number : 5AEF11-2800 Rev May 2019
Quantity :1 Efficiency : 72.37 %
Quote Number / ID Rated power (based on duty point) : 72.5 hp
Date last saved NPSH required :-
Flow, rated : 750 USgpm Viscosity : 1.00 cP
Differential head / : 120.0 psi Cq/Ch/Ce/Cn [ANSI/HI 9.6.7-2010] : 1.00 / 1.00 / 1.00 / 1.00
pressure, rated
Fluid density, rated / max : 1.000 / 1.000 SG
Flow Head Efficiency Power NPSHr Thrust, total
(USgpm) (psi) (%) (hp) (ft) (lbf)
0 126.4 0.00 35.7 - -
194 126.5 32.40 44.3 - -
389 125.5 52.79 53.9 - -
583 123.2 65.38 64.1 - -
777 119.3 73.29 73.8 - -
972 113.5 78.48 82.0 - -
1,166 105.6 81.76 87.9 - -
1,361 95.24 82.83 91.3 - -
1,555 82.20 80.24 92.9 - -
1,749 66.22 71.40 94.6 - -
90 Power
Power - hp
60
30
200
180
160
140
10.50 in
63
70
75
120 79
10.40 in
Head - psi
82
100 83
82
79
80 75
8.25 in
60 70
63
40
20
0
0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000
Flow - USgpm
Project name : Eurocomercial 750 gpm@120 psi Tag Number Speed, rated : 2800 rpm
Consulting engineer : Service : Flow, rated : 750 USgpm
Customer : Peerless Model : 5AEF11 Differential head / pressure, rated : 120.0 psi
Customer ref. / PO : Quantity :1 Rated power (based on duty point) : 72.5 hp
Quote Number / ID Quoted By (Sales Office) : Soltex - Chile Max power (non-overloading) : 94.6 hp
Date last saved Quoted By (Sales Engineer) : Cristian Zapata Efficiency : 72.37 %
Stages :1 Based on curve number : 5AEF11-2800 Rev May
2019
90 2800 rpm
Power - hp
200
180
160
140
120
Head - psi
100
80
2800 rpm
60
2520 rpm (Full reject)
40 2240 rpm (Full reject)
1960 rpm (Full reject)
20 1680 rpm (Full reject)
1400 rpm (Full reject)
0
0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000
Flow - USgpm
Project name : Eurocomercial 750 gpm@120 psi Tag Number Speed, rated : 2800 rpm
Consulting engineer : Service : Flow, rated : 750 USgpm
Customer : Peerless Model : 5AEF11 Differential head / pressure, rated : 120.0 psi
Customer ref. / PO : Quantity :1 Fluid density, rated / max : 1.000 / 1.000 SG
Quote Number / ID Quoted By (Sales Office) : Soltex - Chile Viscosity : 1.00 cP
Date last saved Quoted By (Sales Engineer) : Cristian Zapata Cq/Ch/Ce/Cn [ANSI/HI 9.6.7-2010] : 1.00 / 1.00 / 1.00 / 1.00
Stages :1 Based on curve number : 5AEF11-2800 Rev May
2019
Construction Datasheet
Customer : Quote Number / ID
Customer ref. / PO : Service :-
Tag Number Date last saved
Pump Model : 5AEF11 Quantity :1
General Arrangement
GENERAL
Pump Model 5AEF11
Listing /
FM/UL Listed
Approval
Rated Flow 750 USgpm
Liquid Cold Water
Rated
120.0 psi
Pressure
Specific
0.99824
Gravity
Rated Speed 2800 rpm
Customer
Quote No.
Item No.
Eurocomercial
Project 750
gpm@120 psi
A 16.00 in S 6.75 in GS 1.44 in ZZ 12.50 in AW 13.00 in Date
B 12.00 in SS 13.25 in GD 1.38 in O 20.00 in W 16.00 in
R 5.00 in SF 6.00 in YX 25.00 in D 12.00 in V 2.75 in
J 3.50 in YY 13.00 in Z 6.75 in G 1.00 in KL 2.00 in
E 6.88 in X 12.00 in DF 5.00 in CP 29.00 in U 1.56 in
Axis Axis
Flange Size Units Units
Fx Fy Fz Mx My Mz
2 INCH Lb 200 500 200 Lb-Ft. 500 1000 500
3 INCH Lb 300 750 300 Lb-Ft. 750 1500 750
4 INCH Lb 400 1000 400 Lb-Ft. 1000 2000 1000
5 INCH Lb 500 1250 500 Lb-Ft. 1250 2500 1250
6 INCH Lb 600 1500 600 Lb-Ft. 1500 3000 1500
8 INCH Lb 800 2000 800 Lb-Ft. 2000 4000 2000
10 INCH Lb 930 2330 930 Lb-Ft. 2500 5000 2500
12 INCH Lb 996 2496 996 Lb-Ft. 3000 6000 3000
Axis Axis
Flange Size Units Units
Fx Fy Fz Mx My Mz
2 INCH N 890 2224 890 N-m 678 1356 678
3 INCH N 1334 3336 1334 N-m 1017 2034 1017
4 INCH N 1779 4448 1779 N-m 1356 2712 1356
5 INCH N 2224 5560 2224 N-m 1695 3390 1695
6 INCH N 2669 6672 2669 N-m 2034 4068 2034
8 INCH N 3559 8896 3559 N-m 2712 5423 2712
10 INCH N 4137 10364 4137 N-m 3390 6779 3390
12 INCH N 4430 11103 4430 N-m 4068 8135 4068
Requirements:
1 Fuel tank must comply with the latest version of UL 142 Aboveground Flammable Liquid Tanks
2 Fuel tank must be supplied with a nameplate stating compliance to UL142
3 Tank must be leak proof at 5 to 7 psig per UL 142
4 Tank material will be mild steel unless otherwise stated on purchase order with a thickness compliant to UL142.
5 The “Usable Fuel Volume ” is 90% of the ‘Fuel Tank Volume'. This will provide a ‘Sump Volume ’ of 5% and an ‘Expansion Volume’ of 5%
6 Minimum of a threaded plastic plugs to be installed in all openings
7 Exterior will be painted with red primer paint (Rust-Oleum #7769402 Rusty Metal Primer)
8 Provision for leg connection, legs optionally required
9 Skidding for each tank will conform to Peerless skid drawing 99778631
10 Markings on on either skid or end of tank to minimally include Peerless part number and Purchase order number
11 Per NFPA 20 (sec 11.4.1.5.1.1) Fill pipes that enter the top of the tank shall terminate within 6 in. (152 mm) of the bottom of the tank and shall be installed or
arranged so that vibration is minimized
12
A 1/2" pipe installed in position #6 shall be supplied terminating 3" from bottom of the tank and shall be installed or arranged so that vibration is minimized
13 Actual connection size can be larger with a bushing installed by manufacturer to required connection size.
1 2 2a 3 4 4a 5 6 7 7a 8 9
70 2" NPT 2" NPT 2" NPT 2" NPT 4" NPT 4" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 3/4" NPT 2" NPT
119 2" NPT 2" NPT 2" NPT 2" NPT 4" NPT 4" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 3/4" NPT 2" NPT
140 2" NPT 2" NPT 2" NPT 2" NPT 4" NPT 4" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 3/4" NPT 2" NPT
200 2" NPT 2" NPT 2" NPT 2" NPT 4" NPT 4" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 3/4" NPT 2" NPT
250 2" NPT 2" NPT 2" NPT 2" NPT 4" NPT 4" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 3/4" NPT 2" NPT
359 2" NPT 2" NPT 2" NPT 2" NPT 4" NPT 4" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 3/4" NPT 2" NPT
460 2" NPT 2" NPT 2" NPT 2" NPT 4" NPT 4" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 3/4" NPT 2" NPT
572 2" NPT 2" NPT 2" NPT 2" NPT 4" NPT 4" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 3/4" NPT 2" NPT
650 2" NPT 2" NPT 2" NPT 2" NPT 4" NPT 4" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 3/4" NPT 2" NPT
849 2" NPT 2" NPT 2" NPT 2" NPT 4" NPT 4" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 3/4" NPT 2" NPT
849Z 2" NPT 2" NPT 2" NPT 2" NPT 4" NPT 4" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 1.5" NPT 2" NPT
1100 2" NPT 2" NPT 2" NPT 2" NPT 6" NPT 6" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 3/4" NPT 2" NPT
1100Z 2" NPT 2" NPT 2" NPT 2" NPT 6" NPT 6" NPT 1-1/2" NPT 1/2" NPT 1" NPT 1" NPT 1.5" NPT 2" NPT
Notes
A This fuel system complies with the recommended practices described in the NFPA 20 and UL 142
B The supply tank shall be located so the fuel supply pipe connection to the engine is no lower than the centerline of the engine
fuel transfer pump inlet. The engine manufacturer’s fuel pump static head pressure limits shall not be exceeded when the level
of fuel in the tank is at a maximum
C Fuel tank should be located as close to the engine as possible
D Fuel tank should be pitched 1/4" (6mm) per foot toward drain plug (17)
E Fuel tank must be located above ground, with provisions to prevent freezing
F The 'Usable Fuel Volume' is 90% of the 'Fuel Tank Volume'. This will provide a 'Sump Volume' of 5% and an 'Expansion Volume' of 5%
G 'Fill Cap ' (5) has provisions to be padlocked closed
H 'Locking Valve ' (1) has provisions to be padlocked open
I 'Fuel Gauge ', if ordered, should be located at the 2" NPT opening (7)
J Low Level Fuel Switch ', if ordered with controller, should be located at the 1-1/2" NPT opening (14)
K Only items marked with 'Peerless' will be furnished, other items are furnished "By Other ' to conform to individual job requirements
L Components shown are shipped loose for field assembly
M Illustration is for component identification only. Actual installation must meet local codes and all applicable standards
N Selection of fuel tank with larger 1.5" opening required for fuel system.
A B C D E F G H J K Part # Weight
Fuel Tank
Vent
Volume (US Foot Outside Front tank Tank with Tank&Skid
Tank OD Tank Length Foot Width Fuel Outlet Connection Distance Distance Tank Only
Gal) Distance Foot to Foot (4) legs lbs (kg)
Size
70 24 (610) 36 (914) 24 (610) 16.88 (429) 20.88 (530) 2.5 (64) 6 (152) 4" NPT 5 (127) 5 (127) 99777294 99777346 200 (91)
119 24 (610) 61 (1549) 44 (1118) 14 (356) 18 (457) 2.37 (60) 8.5 (216) 4" NPT 6 (152) 18 (457) 99777295 99777347 250 (114)
140 24 (610) 72 (1829) 42 (1067) 16.88 (429) 20.88 (530) 2.75 (70) 15 (381) 4" NPT 6 (152) 18 (457) 99777296 99777348 335 (153)
200 32 (813) 60 (1524) 44 (1118) 22.62 (575) 26.62 (676) 3.25 (83) 8 (203) 4" NPT 6 (152) 18 (457) 99777297 99777349 410 (187)
250 32 (813) 72 (1829) 42 (1067) 22.62 (575) 26.62 (676) 3.25 (83) 15 (381) 4" NPT 6 (152) 18 (457) 99777298 99777350 460 (209)
359 38 (965) 73 (1854) 44 (1118) 23 (584) 27 (686) 3.75 (95) 14.5 (368) 4" NPT 6 (152) 18 (457) 99777299 99777351 550 (250)
460 48 (1219) 60 (1524) 44 (1118) 34 (864) 38 (965) 4.75 (121) 8 (203) 4" NPT 6 (152) 18 (457) 99777300 99777352 650 (296)
572 48 (1219) 73 (1854) 44 (1118) 30 (762) 34 (864) 4.75 (121) 14.5 (368) 4" NPT 6 (152) 18 (457) 99777301 99777353 740 (336)
650 52 (1321) 71 (1803) 44 (1118) 30 (762) 34 (864) 5.25 (133) 17.75 (451) 4" NPT 6 (152) 18 (457) 99777302 99777354 950 (432)
849 64 (1626) 61 (1549) 44 (1118) 30 (762) 34 (864) 6.25 (159) 8.5 (216) 4" NPT 6 (152) 18 (457) 99777333 99777355 1200 (545)
849(9) 64 (1626) 61 (1549) 44 (1118) 30 (762) 34 (864) 6.25 (159) 8.5 (216) 4" NPT 6 (152) 18 (457) 99777333 99777355 1200 (545)
1100 64 (1626) 79 (2007) 44 (1118) 30 (762) 34 (864) 6.25 (159) 17.5 (445) 6" NPT 6 (152) 18 (457) 99777334 99777356 1785 (811)
1100(9) 64 (1626) 79 (2007) 44 (1118) 30 (762) 34 (864) 6.25 (159) 17.5 (445) 6" NPT 6 (152) 18 (457) 99777334 99777356 1785 (811)
Notes
1 All dimensions are noted in inches (mm) and may vary by 1/4"
2 The supply tank shall be located so the fuel supply pipe connection to the engine is no lower than the centerline of the engine fuel
transfer pump inlet. The engine manufacturer’s fuel pump static head pressure limits shall not be exceeded when the level of fuel
in the tank is at a maximum
3 Fuel tank should be located as close to the engine as possible
4 Fuel tank should be pitched 1/4" (6mm) per foot toward drain plug (17)
5 Fuel tank must be located above ground, with provisions to prevent freezing
6 The 'Usable Fuel Volume ' is 90% of the 'Fuel Tank Volume ' This will provide a 'Sump Volume ' of 5% and an 'Expansion Volume ' of 5%
7 Leg connection 2" NPT (4 places), optionally supplied
8 Add an additional 100 lbs (45 kg) weight for legs
9 Fuel tanks have a 1.5" fuel outlet connection for larger engines. Select with proper fuel system as required.
Pump
Qty Description
1 5AEF11
Fire Pump System
Mount
Mounting type: Mounted on base with driver
Pump
Pump model: 5AEF11
Pump listing: FM/UL/ULC Listed
Selected pump listing: FM/UL Listed
Casing material: Cast Iron
Suction flange: 125lb ANSI Flat faced
Discharge flange: 125lb ANSI CI Flat faced
Casing ring: Bismuth tin bronze
Impeller material: Silicon Brass
Impeller ring: Integral
Rotation: Clockwise (RH)
Bearing solution: Single row outboard grease lube bearing
Shaft material: Carbon steel
Shaft sleeve material: 304SS with O-ring
Lantern Ring: Lantern ring with seal piping
Packing type: Standard
Nameplate units: US
Performance Tests
Performance Tests: Non-witnessed Performance Test
Hydrostatic Pressure Tests
Hydrostatic Pressure Tests: Non-witnessed Hydrostatic Test
Export Shipment Boxing: Skid box, pump/engine
Driver
Qty Description
1 Fire Pump System
Pump
Baseplate design: Non drip rim
Driver Type
Engine manufacturer: All engines
Engine cooling type: Heat exchanger cooled
Pressure limiting: No
Emission tier: Any
Engine: Clarke JU4H-UF34, 104hp, 2800rpm, Emission tier level T1
Engine voltage: 12 Volt DC
Cooling loop: FM Steel Cooling loop
Drive shaft: UL Listed drive-shaft, flywheel adapter, companion flange, & guard
Water jacket heater voltage: 230/240 VAC
Flexible exhaust connector: 4" 150# Flex Exhaust Standard Size
Battery kits: 12 V Battery kit (Lead acid dry batteries, rack, and cables)
EIEO Silencer: Residential grade
Fuel tank
Tank standard: UL 142
Wall type: Single wall
42 in Mounting legs: Yes
Fuel system
Ventilation: Standard ventilation
Controller
Qty Description
1 Base mounted controller adapter: No
Controller brand: Tornatech
Controller voltage: 220 V
Controller charger voltage: 12 V
Controller frequency: 50/60 Hz
Direct ship controller: No
Controller type: Tornatech GPD Diesel Engine Driven Fire Pump Controller, 208-240V, 5060hz
Enclosure: - NEMA 2
Enclosure type: NEMA Type 2
Pressure transducers
Pressure transducers: - Standard pressure transducer
High and low fuel level floats
High and low fuel level floats: -D7A Low fuel level float 1-1/4" (supplied as separate item)
Mounting stands: -D25 Mounting stand (steel, painted)
Alarm Panel: None
Accessories
Qty Description
1 Fuel tank selected: UL Listed, Single wall 119gal
Leak sensor: No
Direct reading fuel gauge: Gauge, Krueger, 70 - 140 Gal.
Fuel System Selected: Fuel system, 0.5"w 4" Standard ventilation, Single Wall, Listing: UL
Jockey pump casing relief valve: None selected
Air release valve: Air Release Valve, ClaVal 0.5", 300psi MWP, 0psi
Gauge: -14InHg/290psi Suction, 0-300psi Discharge
Suction control valve: None selected
Eccentric reducer: None selected
Concentric reducer: None selected
Main relief valve: Valve, relief angle, Cla-Val, 4" ANSI flange, 150lb ANSI, Pilot operated, 20-200psi, 200psi MWP, UL/FM Listed
Overflow cone: 4" x 6", 125lb x 125lb
Flush Mount Test Header Assembly: None selected
Hose valve head: None selected
Hose valve: None selected
Flow Meter Selected: None selected
Jockey Pump
Qty Description
1 Jockey pump supply: Grundfos CR
Frequency: 50 Hz
Phase: Three
Voltage: 380 V
Flow rate: Flow rated: 15 USgpm
Total discharge head: Total discharge head: 130.0 psi
Jockey pump selected: CR 3-17-3ph/2.012Hp 1.50kW FT115 Fr Duty point: 12.3USgpm, 125psi, Shutoff pressure: 159.1psi, 380V, ANSI
flange, HQQE Seal type
Jockey pump companion flange kit: None