Sunteți pe pagina 1din 1

1 2 3 4 5 6 7 8

PART MATERIAL DESCRIPTION SIZE ITEM CODE QTY. SPEC


No

FABRICATION MATERIALS
N
PIPE SUPPORTS
1 Design Pipe Assembly 50 DesignPipeH_5 22 B10
ERECTION MATERIALS
A 2 Pipe, MTE, Galvanized, 50 PAAZZBNAEABAABOAAZZUS 43.6 M A
ASME-B36.10M, A53-B, Seamless,
S-40
3 90 degree elbow, Female 50 MCKAWBUAEAAGABQZZUS 3 B10 16
45 11
threaded end, 3 S1
50DN 20 10GCF10BQ016
Galvanized,ASME-B16.11, A105, SEE ISO 03
CL 3000 10GCF10BR001 SHT 03 <8
4 Coupling, Female threaded end, 50 MAKAWBUAEAAGABQZZUS 6 B10 E 283925 > 20
2 01 S1
Galvanized,ASME-B16.11, A105, N 244300 45
R0 EL +138 10GCF10BQ018
CL 3000 316 1637
S1
10GCF10BQ015
48 20
02 20
S1 87
20 0
10GCF10BQ017 02
1636
4
B <7> 2 311 B
S1 48 S1
20
10GCF10BQ019 03 10GCF10BQ021
S1
20
10GCF10BQ020 03
1645
4 1156
<6> 2 310
S1
48
10GCF10BQ022
S1
10GCF10BQ023 45
4 <5> 2
3
S1
S1 2
10GCF10BQ024 >
C 10GCF10BQ026 <4 C
1697
S1 45
10GCF10BQ027 98 S1
19 10GCF10BQ025
4
98
S1
2 19
10GCF10BQ028 >
S1 <3
10GCF10BQ029 15 238
17
S1 S1
10GCF10BQ030 9 9
10GCF10BQ031 19 48
S1 236
02
10GCF10BQ033 20
2
>
<2 4
4 12
15 23
S1 17
D 10GCF10BQ035 D
02
20 48
4
S1 98
10GCF10BQ036 2 19 S1
<1> 10GCF10BQ032
22

478
SEE SHT 17 237
10GCF10BR001 SHT 01 48
E 260801 88
19 S1
N 223430 156
EL +228 45 10GCF10BQ034
50DN
3
EL +183 1189
45

E E
8 5931 50 SCREWED SCREWED PAAZZBNAEABAABOAAZZUS
7 5952 50 SCREWED SCREWED PAAZZBNAEABAABOAAZZUS
6 5952 50 SCREWED SCREWED PAAZZBNAEABAABOAAZZUS OWNER
5 2801 50 SCREWED SCREWED PAAZZBNAEABAABOAAZZUS
4 5931 50 SCREWED SCREWED PAAZZBNAEABAABOAAZZUS DISTRIBUTION W/C
3 5952 50 SCREWED SCREWED PAAZZBNAEABAABOAAZZUS MATRIX
2 5952 50 SCREWED SCREWED PAAZZBNAEABAABOAAZZUS
1 5055 50 SCREWED SCREWED PAAZZBNAEABAABOAAZZUS NOTES:- EPC
PIECE
NO
LENGTH
MM
SIZE
MM
END PREP END PREP ITEM CODE
1. ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS
2. FINISHED GROUND LEVEL (FGL) OF PLANT IS (-)0.300 WHICH
CORRESPONDS TO MSL (+)8.50M
PESCO
3. FOR PAINTING & SURFACE PREPARATION DETAILS REFER "TECHNICAL
SPECIFICATION FOR PAITING" DOC NO. TCE.11191A-SP-3903 MAIN PLANT EQUIPMENT SUPPLIER
4. FOR INSULATION DETAILS REFER "TECHNICAL SPECIFICATION FOR
INSULATION" DOC NO. TCE.11191A-SP-3902
5. ALL ELEVATIONS INDICATED ARE CENTER LINE OF PIPES UNLESS
OTHERWISE NOTED. PROJECT NAME
6. SMALL BORE PIPING (DN 50 & BELOW) ARE FIELD RUN. ISOMETRICS
ISSUED FOR THE SAME IS INDICATIVE AND MAY BE ADJUSTED TO SUIT ADEN POWER PLANT - PHASE 1
F SITE CONDITIONS. F
7. FOR SUPPORT ARRANGEMENT, REFER TYPICAL STANDARD SKETCH
DRAWING - TCE.11191A-D-4909 DRAWING TITLE ISOMETRICS FOR RAW WATER AND SERVICE
8. VICTAULIC PIPE FITTINGS SHALL NOT REST ON SUPPORTS AND SHALL
R0
WATER DISTRIBUTION SYSTEM
HAVE AMPLE CLEARANCE FROM SUPPORT.
10GCF10BR001 02 of 04
P&ID NO. ENGINEERING JOB No. DRAWING NUMBER REV
PIPING LAYOUT DRAWING NO. No. DATE REVISION DESCRIPTION BY CHK APPR Civil Mech Elect I/C PIP HSE PROS
11191A TCE.11191A-D-4916 R0
FILE NAME 10GCF10BR001.SHA DATE : DESIGNED : DRAWN : CHEF ENGR : TATA CONSULTING ENGINEERS LIMITED

1 2 3 4 5 6 7 8

S-ar putea să vă placă și