Sunteți pe pagina 1din 1

ORTH

Refer to Footing R.C Details


Refer to Footing R.C Details

Refer to Footing R.C Details

Refer to Footing R.C Details


X X X X NOTES

B1
T1
1- Steel fy not less than 460 N/mm2.
B2 2- Concrete fcu should not be less
T2 than 30N/mm2 for 28days strength.

B1
T1
X X
3-Max-Aggregate size 20mm for
Refer to Footing R.C Details Refer to Footing R.C Details beams & col.s and 30mm for found.s.
FOUNDATION PLAN (F1,F2,&F3) FOUNDATION PLAN (F4) 4- Concrete cover for reinforcement
should not be less than
25mm for beams & columns and
50mm for foundations.
5- Over laps of steel should not be less
B2 than 45 times larger bar size &should
T2 always be located within concrete
being under compression.
Refer to Footing R.C Details Refer to Footing R.C Details
Refer to Footing R.C Details
6- Construction joints shall be located
Refer to Footing R.C Details at onefifth of span of slabs.
RAFT FOOTING PLAN 7- All Dimensions are in mm.
8- Bearing Capacity= 180 KN/m2.
Refer to Footing R.C Details

Selected Material 50 cm Compacted Selected Material 50 cm Compacted


to 95% M.D.D. to 95% M.D.D.

SECTION ELEVATION X-X SECTION ELEVATION X-X Selected Material 50 cm Compacted


(F1,F2,&F3) (F4) to 95% M.D.D.

FOOTINGS R.C. DETAILS RAFT SECTION X-X


Bilbaraka For Engineering Consultancy
Khartoum - Sudan
Almanshia - Altayeb A.Allah St.
Mob. : +249912910731
Email: taha.elnour@gmail.com

PROJECT TITLE Plot No:


(1168)
RESIDENTIAL BUILDING Block No:
(81)

LOCATION
Khartoum - Algeref west

OWNER
Mr. OTHMAN IBRAHIM ALBOUR

DRAWING TITLE Job No


FOUNDATION DETAILS
Scale 1 :100

Str. Design Eng. Sharif Abdallah Agban

Str. Design
Eng. Sharif Abdallah Agban
Str. Drafting

Approved By Eng. Taha Elnour Isshage

File name Date Rev. Sheet No


FOUNDATION DETAILS JUNE-2019 ST-06