BASIS OF DESIGN
for
OmniSulf®
OWNER
ExxonMobil/Qatar Petroleum
CONTRACTOR
Chiyoda Corporation
Section Page
1 INTRODUCTION 4
2 PROCESS 5
2.1 PROCESS DESCRIPTION 5
2.2 BLOCK FLOW DIAGRAM 7
3 BATTERY LIMITS 8
3.1 DEFINITION OF BATTERY LIMITS 8
3.2 BATTERY LIMIT CONDITIONS OF PROCESS STREAMS 9
4 DESIGN PARAMETERS 10
4.1 UNIT CAPACITY AND FEED GAS CONDITION AND COMPOSITION 10
4.2 PRODUCT SPECIFICATION 13
4.3 SULPHUR RECOVERY 14
4.4 TURN DOWN 15
4.5 UTILITIES 16
4.6 METEOROGICAL DATA 20
4.7 ADDITIONAL DESIGN INFORMATION 21
5 Engineering documents 24
6 Numbering 25
6.1 UNIT NUMBERING 25
6.2 EQUIPMENT NUMBERING 26
6.3 PROCESS STREAM NUMBERING 27
6.4 NUMBERING OF PIPING 27
6.5 INSTRUMENT TAG NUMBER 32
6.6 ELECTRICAL IDENTIFICATION 34
7 UNITS OF MEASUREMENT 35
The client, Exxon Mobile / Qatar Petroleum, wishes to establish an LNG facility on the Persian Gulf
coast, in Ras – Laffan City. The LNG plant will receive, process and store LNG in one train.
The feed gas must be treated in the gas treating facilities to remove all CO2 to prevent freezing in the
downstream liquefaction plant and remove Sulphur components in order to meet LNG product
specifications.
The purpose of this document is to summarize the technical specification and requirements to be used
®
by Lurgi Öl Gas Chemie GmbH in preparing the Basic Process Engineering for the OmniSulf process.
Lurgi will consider Chiyoda’s following project procedures and/or project specifications to extent as it is
necessary and relevant for the scope of Lurgi’s supply:
QG II/20/02/PR/TS/NA/001 Technical Requirement for Acid Gas Removal and Dehydration Unit 02 / 03
QG II/24/09/PR/DP/NA/001 Technical Requirement for Sulphur Recovery Unit
QG II/20/09/PR/TS/NA/001 Technical Specification for Design & Fabrication of Sulfur Recover Units
QG II/20/00/PE/PC/NA/301 Document Numbering Procedure
QG II/20/00/PE/PC/NA/303 Equipment / Line / Instrument Numbering Procedure
QGII/20/00/ME/TS/NA/603 Technical Specification For Design & Fabrication of Refractory Lining of
Sulfur Recovery Unit
2 PROCESS
®
The OmniSulf process is configured to treat all the feed gas in one gas processing train, in the following
called UNIT. The UNIT consists of a Acid Gas Removal Unit (AGR), a Claus Unit (CLS), a Tail Gas
Treating Unit (TGT), an Incineration Unit (INC) and a Degassing process (Hold).
Feed gas from the offshore facilities in the Persian Gulf is received in the Slug Catcher and preheated,
®
depressurised and metered prior to be processed in the OmniSulf process.
Treated gas, free of CO2, Sulphur components and water, enters the Liquefaction Unit via a Dehydration
and Mercaptan Removal Unit (DMR), a Mercaptan Recovery Unit (MRU) and a Mercury Removal Unit
for LNG production. DMR, MRU and Mercury Removal downstream the unit are not in the licensor’s
scope of work.
The PROCESSES belonging to the UNIT are interconnected as depicted in the below Block Flow
Scheme:
?
Block Flow Diagram
B.L. B.L.
Off Gas
Liquid Hydrocarbons
RSH Liquid Storage
(Unit )
DSO B.L.
Residue Gas
B.L.
3 BATTERY LIMITS
The Battery Limit conditions of the main feed and product process streams are defined as follows:
FEED GAS:
The UNIT shall be able to handle feed gas with the following compositions and conditions:
o
Temperature, C 40 40 40
Pressure, bar a 68.4 68.4 68.4
Flow Rate (dry basis), kmol/h 72,799.0 72,682.0 72,259.0
1)
Feed gas is saturated at 68.4 bar a. and 35°C.
o
Temperature, C 49.0 49.0 49.0
Pressure, bar a 1.65 1.65 1.65
Flow Rate (wet basis), kmol/h 58.56 56.22 25.60
* The given mercaptan streams and conditions shall be basis of design for SRU. Condition and
composition shall be adjusted by licensor of Dehydration & Mercaptan Removal Unit (Unit 03) later.
Mercaptan stream fluctuation shall be within
!"$#%&'(*)
SWEET GAS
The purified and conditioned product gas to be send to the DMR unit has the following properties:
Quality:
H2S content (ppm vol) 2.0 (guaranteed value)
CO2 content (ppm vol): 10.0 (guaranteed value)
COS content (ppm vol): 1.0 (guaranteed value)
Methyl Mercaptan content (ppm vol): 75.0 (expected value)
Ethyl Mercaptan content (ppm vol): 140.0 (expected value)
LIQUID SULPHUR
Quality:
Purity (dry basis): ≥ 99.8 %
1)
H2S: ≤ 10 ppm wt
Ash: ≤ 300 ppm wt.
Organics: ≤ 500 ppm wt.
Color: Bright yellow
1) The H2S content of the liquid sulphur can only be guaranteed with a Degassing unit included in the
package.
The total sulfur recovery rate shall be based on the feed gas to AGRU plus SO2 feed to SRU (Total
Sulfur Feed). The overall sulfur recovery achieved in SRU shall be >99.0%.
The total sulfur recovery shall be guaranteed as more than 99.0% of the sulfur contained in the Total
Sulfur Feed. Sulfur recovery shall be calculated using the following equation ;
The sulfur recovery guarantee shall be based upon the maximum mercaptan co-absorption by the
Acid Gas Removal Unit (Unit 02) solvent specified by AGR Licensor. The mercaptan (RSH) removed
in Unit 02 will be fed to the AGE and processed to the TGTU Hydrogenation Reactor. Non-converted
mercaptans will be released to Incinerator.
*)
Mercaptan Species Co-Absorption Rate
C1SH 50 %
C2SH 40 %
C3SH 15 %
C4SH 10 %
C5SH+ 10 %
*): Max. expected co-Absorption rate in AGR (Unit 02).
(3) Lurgi shall prepare the plant overall sulfur material balance for all feed gas cases to account for all
the sulfur entering the AGRU. Material balance data for facilities outside of Lurgi scope will be
provided by Chiyoda.
The overall unit is designed for processing the amount of gas specified in chapter 3.1. For the turn down
this gas capacity is defined as 100%. The turn down ratio of the unit is 40% of the design gas capacity.
Operation Design
pressure p [bar g.] / P gauge T
temperature t [°C]
Consumer [barg] [°C]
p t
5)
HHP Steam 62/61 440/430 69 72 & FV 470.0
5) 2)
HP Steam 25.0/25 226/226 28.0 & FV 255.0
5)
MP Steam 10.0/9.5 210/205 12.5 & FV 240.0
5)
LP Steam 4.5/4.1 165/160 7.0 & FV 195.0
6)
Condensate System
HP Condensate 4.1 153 7 & FV 195
MP Condensate 4.1 153 7 & FV 195
LP Condensate 1 120 3.5 & FV 180
BFW System
BFW 28.0 80 120.0 35.0 127 148.0
Demin Water System
Demineralized Water 2.7 amb 8 45
3)
Cooling Water Supply 4.0 Max. 38 10 & FV 55.0
min. 3.0 Min. 18
4) 3)
Cooling Water Return Max. 48 10 & FV 55.0
Service Water 5 amb 15 45
Instrum. Air System 7.5 / amb 10 70
min. 4.5
Nitrogen System 7.3 amb. 10 70
Boil Off Gas (BOG) 29.0 36.5 ~ 35 100
43.5
End Flash Gas (EFG) 5.0 36.5 ~ 10.4 100
43.5
for Incinerator Burner
Residue Gas 65.8 36.5 ~ 76 100
43.5
FV = Full Vacuum
amb = ambient Temperature
2) HP steam is generated and consumed in SRU only. The condition of HP steam shall be specified by
SRU Licensor.
3) FV for aboveground only
4) Maximum pressure loss 1 bar
5) Blow down shall be routed to B.L at operating temperature of steam producer.
6) Condensate will be saturate to B.L. pressure
Condensate recovery system (piping, pump, cooler(s), vessels) outside Licensor’s scope
BFW
Composition:
1)
Total solids; dissolved: 3 (mg/l)
2)
2 (mg/l)
Silica as SiO2 0.00 (mg/l)
Dissolved oxygen as O2: 0.007 (mg/l)
Physical Properties:
1)
Conductivity: 6 microS/cm
2)
4 microS/cm
0
pH range (at 20 C): 9.0 to 9.5
DEMINERALIZED WATER
Composition:
Total solids; dissolved: 5.0 mg/l
Total alkali and other metals: 0.5 mg/l
Silica as SiO2 0.00 (mg/l)
Physical Properties:
0
pH range (at 20 C): 6.5 to 7.5
Conductivity (at 25 °C): < 0.05 micro S/cm
Note:
1) Condensate Max. Loss Case
2) Normal Operational Case
RESIDUE GAS
FLARE:
Back pressure of flare system at battery limits: Wet Gas Flare: 6 barg
Acid Gas Flare: 0.1 barg
PRESSURE REFERENCE
Liquid pressures, given in chapter 4, are referenced to grade.
In the event of a conflict between this specification and any one of the Process Licensor’s sizing/design
criteria Licensor’s criteria shall prevail.
In the event of a conflict between this specification and any one of the Process Licensor’s sizing/design
criteria Licensor’s criteria shall prevail.
Medium m2 • K
Fouling Factor ( )
W
Process Gases Feed Gas 0.00018
Clean Gas 0.00018
Regeneration Gas 0.00018
Sour Gas 0.00036
Claus/TGT Process Gas 0.00260
2)
Utilities HP Steam 0.00010
2)
MP Steam 0.00010
2)
LP Steam 0.00010
2)
Boiler Feed Water 0.00026
2)
Cooling Water 0.00018
2)
Ambient Air for Air Cooling 0.00026
Remarks:
1) Overdesign = 20% (added to clean surface)
2) To be defined / confirmed by Consultant / Client
For reference for the lay out of documents please refer to this document.
Note:
When the documents for Train-1 are identical and only equipment, piping, instrument numbering are
different, use as a common document with the following note:
TYPICAL FOR
ONE SRU TRAIN
2 4 - E M 0 2 3 3 A
1 2 3 4 5
Process streams in the PFD and material balance table will be numbered as follows:
2 4 0 9 1 0 1
1 2 3
C W 2 4 0 0 0 0 1 - 1 0 “( 6 R 3 B S )- 1 ( - 4 0 )( 2 4 )
1 2 3 4 5 6 7 8
0 0 0 0 1
1 2
1: 2 digits – Unit Code (“02” for aMDEA, “09” for AGE, SRU, TGT, Degassing)
2: 3 digits – Serial Number (001 through 999)
1 P 3 K L C 1
1 2 3 4 5 6
Atmospheric Vent AV
, , , ,
Waste Water WW
, ,
Acid AC
Sour Gas Flare SF Desalinated Water (Raw Water) RW
Wet Gas Flare RV
, ,
Dry Gas Flare CV
, ,
Catalyst CA
Code Description
S Stress Relieve
U B31.1
P B31.8 ( Stress Relieve)
B31.8 Slug Catcher ( Stress
Q
Relieved )
Blank Jacketed Piping
2 4 D P L L 0 2 0 0 1
1 2 3 4 5 6 7
first letter covering the measured or initiating variable, and one or more succeeding letters covering
the functions of the individual instrument, one or more readout or passive functions, or output
function, or both.
2. Modifying letters may modify either a first-letter or other succeeding letters, as applicable.
3. The sequence of identification letters shall begin with a first-letter. Readout or passive functional
letters shall follow in any sequence and output functional letters shall follow these in any sequence
except that output letter C (control) shall precede output letter V (valve); e.g. HCV, a hand-actuated
control valve. However, modifying letters, if used, shall be interposed so that they are placed
immediately following the letters they modify.
4. Any first-letter, if used in combination with modifying letters D (differential), F (ratio) or Q (integrate or
totalize), or any combination of them shall be construed to represent a new and separate measured
variable and the combination shall be treated as a first letter entity.
Hold