Sunteți pe pagina 1din 8

IRCON/S&T/5016/RE.MGS-UTR/Sigg. Work/05 Date: 02.03.

09

BILL OF QUANTITIES
IRCON/S&T/5016/RE.MGS-UTR/Sigg. Work/05 Date: 02.03.09
BILL OF QUANTITIES

Name of Work:- Supply, installation, testing & commissioning of outdoor Signalling gears for modification of existing
RRI at Varanasi station to suit 25 KV AC Traction on UTR – MGS section of Northern Railway.

Sr. Description of work Appr. UNIT Unit Rate in Unit Rate in words Cost in figures
No. Qty. figures (in Rs.) (in Rupees)
(in Rs.)

1 Trenching in all type of soil, Rock mixed


soil, stone paved road, concrete platform
etc. and chase cutting for rock and refilling
of trenches from Distant to Distant Signal
on either side of station alongside Track
and in yard & under the Track as per the
detailed items mentioned under vide item
no. i(a) to vii. The work shall be done as
per item 1 of Technical Specification of
Encl. - 1.

i(a) Excavation and refilling of trench to the 6000 P.Mtr.


level of ground with rammed earth so as
not to form a drain, 0.4 Mtr wide and x 1.0
Mtr deep on both side of the station along
side track. It also includes clearance of
roots of trees and bushes.

i(b) Excavation and refilling of trench to the 15510 P.Mtr.


level of ground with rammed earth so as
not to form a drain, 0.4 Mtr wide and x 1.0
Mtr deep along side track in Station
section in Varanasi yard in normal soil.

ii) Excavation and refilling of trench 0.4 Mtr 100 P.Mtr.


wide and x 1.0 Mtr deep from bottom of rail
sleeper across the track. Earth shall be
rammed so as not to form drain. This
includes removal and refilling of ballast
and restoration of surface under normal
traffic condition.

iii) Digging and making brick channel 0.4 Mt 315 P.Mtr.


wide x 0.3 M deep on metalled / cemented
platform with collar for accomodating for
cover slabs on channel after cable laying
and filling the top of the cover slab with
seived soil and repair of platforn in original
condition. The top of the cover slab on
channel shall be 5 Cm below the platform
level. All the materials will be supplied by
contractor.
iv) Excavation and refilling of trench 0.4 Mt. 75.83 P.Mtr.
wide and 0.8 mt. deep on pitched/stone/
brick paved surface, road crossing
/platform etc. and restoring the surface to
its original condition.

v) Supply and laying of second class bricks in 216400 Per Brick


the trench.

vi) Termination of all cores of all types of out 4950 Per core
door cables after its laying on both end.
This also includes preparation of test
report for core to core and core to earth on
prescribed proforma for each core of the
cable separately. This also includes
dressing and lacing of the cable on both
ends. Proforma for testing and materials
for lacing to be supplied by contractor.

vii) Fabrication, supply and fixing of cable 782 Per


marker of 1:3:6 concrete. Marker

2 Laying of Signalling cable of different sizes 100 Km.


as per cable route plan approved by
Railway and meggering of all Main & Tail
cables as per item No. 1 of Technical
specifications of Enclosure-I.. 2 core to 24
core(1.5/2.5 sq. mm.) and 2 core 25 sq.
mm. Aluminium power cable.

3 Supply and laying of RCC split/full pipe 300 No.


150 mm dia 2 metre long in trenches near
traction substation, laying in the trench
already made for track crossing and Road
crossings etc and wherever applicable as
desired by Engineer at site.

4 Casting, concreting & curing of foundation 114 No.


and erection for single apparatus case as
per item 2 of technical specification of
enclosure I.
5 Casting, concreting & curing of foundation 35 No.
and erection for half apparatus case as per
item 2 of technical specification of
enclosure I.

6 Casting, concreting & curing of foundation 9 No.


and erection for junction boxes as per item
2 of technical specification of enclosure I.

7 Alteration of wiring in existing apparatus 78 No.


cases single/half. This includes supply of
all materials in connection with alteration in
wiring, except Railway supply items and
ARA terminals.

8 Shifting of existing colour light signal with 5 No.


foundation along the track to meet the
schedule of dimension required in
connection with RE modification.

9 Provision of screen on signal when they 42 No.


fall within two meters from live conductor
by expanding Metal. Size 20 mm x 60 mm
(strand 3.25 mm wide and 1.6mm thick) as
per instructions at site by Engineer
Incharge. This includes supply of all
materials including earth electrode and
earthing arrangement.

10 Supply & installation of wire insulator for 36 No. of


wire operating Level Crossing lifting wire
barriers/Signals as per Specification No. insulator
IRS-S-47-74.

11 Supply & installation of Insulator of Point 28 No. of


Rodding at function end & Lever end as rod
per Item No. 5 (VIII ) of Tech. Specification insulator
of Encl - I.
12 Supply, Installation and commissioning of 8 No. of
Rotary Key Transmitter suitable for RE RKT
area as per Drg. No. SA - 2260/M for
siding point/LC Gate as per circuit
Diagram. This includes supply of all
materials for installation of RKT as per
Item No. 5(VI ) of Technical Specification
of Enclosure-I.

13 Supply & installation of Track circuit 200 No.


equipment excluding glued joint or Block
joint, for modification of existing track
circuit as per item 6 of technical
Specification of Enclosure – I. All material
except Track Feed Battery charger, Sec.
Cells, Relays, U/G signalling tail cable
from location box to TLJB, Cable 2x2.5
sq.mm. from TLJB to rail, Machine fish
plate with longer nuts and bolts required
for installation & commissioning of track
circuit shall be supplied by contractor
including but not limited to the item
mentioned below a) Disc type Track feed
resistance, bonding wire 8SWG, bond wire
clip, channel pin single groove, b) ND type
fuse of 2 Amp, c) insulation for rail joint,
gauge tie plate, stretcher bar and switch
extension bracket, d) Choke B type as per
IRS-S-65/83 or latest, e) Track lead
junction boxes. The items from a) to e)
shall be supplied as per site requirement.
Note:- Block/ Glued joint will be supplied &
installed by Railways.

14 Supply and fitting of ‘E’ type lock with all 20 No.


accessories for Relay Room / Equipment
Room / Battery Room.

15 Supply & installation of earth Electrode 678 No. of


including earth wire for signalling Earth
equipments as lever frames, Apparatus Electrod
cases, Signal, relay rack, Block Instrument e
etc. as per Item 10 ( IV) & ( V ) of technical
Specification of Enclosure - I.

16 Cleaning, scraping, painting and lettering 1 10-12


of all newly installed and existing gears by line stn
the contractor for panel interlocked with
colour light signalling station as per item
10 ( I ) & ( II ) of Technical Specification of
Enclosure - I.
17 Modification of existing block instrument / 2 No.
token instrument / tokenless instrument to
suit 25 KV AC traction area as per
standard circuit diagram to be supplied by
Rly. Block bell equipment, Filter unit &
polarised relay / relays shall be supplied by
Railway and all other materials,
condensers , resistance etc. required for
the work shall be supplied by contractor.
This includes wiring of battery charger and
secondary cells, connected to block
instruments. Cost of supply of secondary
cells shall not be included in this item as it
is Railway supply item.

18 Replacement of existing single line 4 No. of


Tokenless block instrument. Installation & Block
wiring, commissioning & testing of New Instrume
Diado Type Single line instrument to suit nt.
25 KV AC traction areas as per standard
circuit diagram to be supplied by railways.
Block Bell equipments, Filter Unit and
polarised relays/relay, Secondary cells and
battery chargers shall be supplied by
Railway and all other materials,
condensers, Resistors etc. required for the
work shall be supplied by contractor.

19 Charging of secondary cells as per Item 624 No.


9( III ) of technical Specification of
Enclosure - I.

20 Supply & installation of Magneto 5 No.


Telephone with all accessories ( stand box
and 3 Nos. of 6I Cells ).

21 Manufacture, supply and installation of 5 No.


cable termination board with fuse bases,
fuses etc as per drawing no.
CORE/S&T/ALD/SK/505 /2001. Fixing of
ARA terminals, etc. as per item 21 of
Technical specification of Enclosure - I.

22 Manufacture, supply and installation of 2 No.


prewired Relay Rack as per drawing no.
RE/S&T/ALD/SK/20/85. Fixing of relays,
point group etc. as per item 21 of
Technical specification of Enclosure – I.
23 Supply and fixing of M.S. angle, Hylam 114 No.
sheet, fuses with base & shelves for single
apparatus cases. Fixing of ARA terminals
and wiring of all equipments including
relays as per item-3 (III),(IV),(V) and item
13 of technical specification of enclosure
-I.

24 Supply and fixing of M..S. angle, Hylam 33 No.


sheet, fuses with base & shelves for half
apparatus cases. Fixing of ARA terminals
and wiring of all equipments including
relays as per item-3 (III),(IV),(V) and item
13 of technical specification of enclosure-
I.

25 Supply and fixing of M..S. angle, Hylam 9 No.


sheet for junction boxes and fixing of
ARA terminals as per item-3 (III),(IV),(V)
and item 13 of technical specification of
enclosure- I.

26 Supply & installation of Track circuit 8 No.


equipment excluding provision of Glued
Joint or Block joint for new installations of
track circuits etc. as per item 6 of
technical Specification of Enclosure - I All
material except Track Feed Battery
charger, Sec. Cells, Relays, U/G signalling
tail cable from location box to TLJB, Cable
2x2.5 sq.mm. from TLJB to rail, Machine
fish plate with longer nuts and bolts
required for installation & commissioning of
track circuit shall be supplied by contractor
including but not limited to the item
mentioned below a) Disc type Track feed
resistance, bonding wire 8SWG, bond wire
clip, channel pin single groove, b) ND type
fuse of 2 Amp, c) insulation for rail joint,
gauge tie plate, stretcher bar and switch
extension bracket, d) Choke B type as per
IRS-S-65/83 or latest, e) Track lead
junction boxes. The items from a) to e)
shall be supplied as per site requirement.
Note:- Block/ Glued joint will be supplied &
installed by Railways.

27 Ring Earthing arrangement for Signal 8 No.


Equipment, Relay Rack, Power Equipment
Etc.
28 Execution of trenchless horizontal boring 1400 Mtrs
(HDD) work (boring size up to 125 mm) up
to a depth of minimum 1.00 metre from the
ground level at location as per direction of
engineer in charge.This includes supply &
laying of DWC HDPE pipe as per
specification No. IS 14930 part II or latest
of 120 mm OD/103 mm ID.

29 Removal of existing point motor and 31 Nos.


installation of immunised motor. Note:-
immunised motor will be supplied by
IRCON.

Total cost in figures in Rs.

Total cost in words in Rs.