Sunteți pe pagina 1din 5

SAUDI ARAMCO ID/PIEU -3- July-2018 - REV. 2018.04.00 (Standards Cutoff -April 30, 2018) Rev. 2018.04.

00 30-Apr-18
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Review Qualifications - MPT Personnel SAIC-MPT-2002 3-Jul-18 NDE-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

A General Requirements (For Subcontractor, Prime Contractor & NDT Service Provider Co.)

NDT Service Provider* has a written practice or procedure covering NDT


(Magnetic particle Testing) personnel training, experience, qualification,
and certification submitted to the Saudi Aramco Inspection Department,
Dhahran and approved.
SAEP-1142
A1 For in-kingdom works, written practice shall meet the minimum
Para. 4.2
requirements of ANSI/ASNT CP-189 (latest edition) plus the additions
and clarifications outlined in SAEP-1142.
*These are one of the SA Approved
NDT Companies.

Personnel performing or evaluating Magnetic Particle Testing results shall


SAEP-1142
A2 be certified in MPT method. (Personnel has submitted his certificate for
Para. 7.2
verification.)

Personnel responsible for interpretation of or affecting results of NDT


SAEP-1142
A3 operations shall be certified to a minimum of Level II per the certifying
Para. 4.4
organization's written practice.

The claimed training and/or experience of the NDT personnel from the
previous employer's) has been obtained and verified by the current
employer and has retained the verification on file. Wet ink originals are SAEP-1142
A4
the only acceptable documentation of previous training. Para. 5.2 & 5.3
Note: Any claimed training or experience that cannot be verified and
documented shall be considered invalid.

The responsible NDT Level III has verified the documentation/certification SAEP-1142
A5
and attested in writing to its validity. Para. 5.3
Vision examinations shall be performed annually according to Section 6 of SAEP-1142
A6
ANSI/ASNT CP-189. Review Records Para. 6.3

Level I and II NDT personnel shall be recertified by the employer as per


SAEP-1142
A7 Section 6 of CP-189, i.e., by examination. Recertification by
Para. 7.3.1
demonstration of experience is not allowed. Review Results.

Level III personnel shall be recertified by verification of the individual's


ASNT Level III certificate in each method for which re-certification is SAEP-1142
A8
sought. A practical examination may be required for level III re- Para. 7.3.2
certification at the discretion of the Saudi Aramco Head Level III.

REMARKS:
Note: 1. Saudi Aramco has the right to request submission of, or granted access to, any and all training, experience, qualification and
certification records pertaining to NDT personnel (SAEP-1142, Para 5.4). Copies of each dossier shall be available in Project Records for
Personnel performing or expected to perform NDE. Coordinate & maintain an NDT Personnel Roster (Certs copy) on all Projects.
Note: 2. This checklist may be used to evaluate each one or a batch of personnel qualifications submitted in one transmittal.

REFERENCE DOCUMENTS: SAEP-1142, Qualification of Non-Saudi Aramco NDT Personnel, 4 Dec 2014.
Contractor / Third-Party Saudi Aramco
Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

Saudi Aramco: Company General Use


Quality Record Approved:
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU -3- July-2018 - REV. 2018.04.00 (Standards Cutoff -April 30, 2018)
Rev. 2018.04.00

3-Jul-18
30-Apr-18