LAUNCH X-431 PADII User's Manual

Copyright Information party without permission from the owner of the applicable trademark,
service mark, domain name, logo, or company name. You may contact
Copyright © 2014 by LAUNCH TECH. CO., LTD. All rights reserved. LAUNCH by visiting the website at www.cnlaunch.com, or writing to
No part of this publication may be reproduced, stored in a retrieval LAUNCH TECH. CO., LTD., Launch Industrial Park, North of Wuhe
system, or transmitted in any form or by any means, electronic, Avenue, Banxuegang, Bantian, Longgang, Shenzhen, Guangdong,
mechanical, photocopying, recording or otherwise, without the prior P.R.China, to request written permission to use Materials on this
written permission of LAUNCH. The information contained herein is manual for purposes or for all other questions relating to this manual.
designed only for the use of this unit. LAUNCH is not responsible for
any use of this information as applied to other units. Safety Precautions
Neither LAUNCH nor its affiliates shall be liable to the purchaser Before using X-431 PADII, please read the following safety information
of this unit or third parties for damages, losses, costs, or expenses carefully.
incurred by purchaser or third parties as a result of: Accident, •• Never collide, throw, or punch X-431 PADII, and avoid dropping,
misuse, or abuse of this unit, or unauthorized modifications, repairs, extruding and blending it.
or alterations to this unit, or failure to strictly comply with LAUNCH •• Do not use X-431 PADII in exceptionally cold or hot, dusty, damp or
operating and maintenance instructions. LAUNCH shall not be liable dry environments.
for any damages or problems arising from the use of any options or •• In places where X-431 PADII is forbidden or using X-431 PADII
any consumable products other than those designated as Original may cause interference or generate a potential risk, please turn it
LAUNCH Products or LAUNCH Approved Products by LAUNCH. off.
Trademark Information •• To ensure a safe driving, please do not use X-431 PADII while
driving.
LAUNCH is a registered trademark of LAUNCH TECH CO.,
•• Turn off X-431 PADII before boarding any airplane.
LTD. (LAUNCH) in China and other countries. All other LAUNCH
trademarks, service marks, domain names, logos, and company •• Do not dismantle X-431 PADII by yourself. If there is any inquiry,
names referred to in this manual are either trademarks, registered please contact the dealer.
trademarks, service marks, domain names, logos, company names of •• Never place X-431 PADII into apparatus with strong electromagnetic
or are otherwise the property of LAUNCH or its affiliates. In countries field.
where any of the LAUNCH trademarks, service marks, domain •• Keep X-431 PADII far away from magnetic devices because its
names, logos and company names are not registered, LAUNCH radiations may erase the data stored on X-431 PADII.
claims other rights associated with unregistered trademarks, service •• Store X-431 PADII out of reach of children and do not allow children
marks, domain names, logos, and company names. Other products to use it unsupervised.
or company names referred to in this manual may be trademarks •• Please use the included battery and charger. Otherwise, explosion
of their respective owners. You may not use any trademark, service may happen.
mark, domain name, logo, or company name of LAUNCH or any third

II
LAUNCH X-431 PADII User's Manual

•• Do not disconnect power abruptly when X-431 PADII is being Table of Contents
formatted or in process of uploading or downloading. Or else it may
result in program error. 1 Introduction...................................................................................... 1
1.1 Product Profile................................................................................ 1
Precautions on Using X-431 PADII 1.2 Features......................................................................................... 1
•• The ignition switch should be OFF while plugging or unplugging the 1.3 Technical Specifications................................................................. 1
diagnostic connector. 2 Knowledge of X-431 PADII.............................................................. 2
•• When the diagnostic connector is not used, remember to place 2.1 X-431 PADII Tablet......................................................................... 3
it into the diagnostic connector housing located on the docking 2.2 X-431 PADII Docking Station.......................................................... 4
station to avoid loss. 2.3 Diagnostic Connector..................................................................... 5
•• If your vehicle keeps unattended for a week or a long period, it 2.4 X-431 PADII Accessory Checklist................................................... 5
is suggested to unplug the connector from vehicle’s DLC to save 3 Preparations.................................................................................... 7
battery power. 3.1 Charging X-431 PADII.................................................................... 7
•• While diagnosing a vehicle, you are not advised to use phone 3.2 On Using Your Battery.................................................................... 7
or messaging, because it may cause a data communication 3.3 Power On / Power Off X-431 PADII . ............................................. 8
interruption. If it happens, it is abnormal and just try to re-do it. 3.3.1 Power on............................................................................... 8
3.3.2 Power off............................................................................... 8
Precautions on Operating Vehicle’s ECU 3.4 Tips On Finger Operations............................................................. 8
•• Do not disconnect the vehicle inner consumer when the ignition 3.5 Lock / Unlock the screen................................................................ 8
switch is ON. High voltage transients may encounter at the moment 3.5.1 Lock the screen..................................................................... 8
of disconnecting, which may damage the sensors and the ECU.
3.5.2 Unlock the screen.................................................................. 8
•• Protect the computer from magnetic object.
3.6 Screen Layout................................................................................ 9
•• Do cut off the power supply of ECU system before welding on the 3.7 Status Bar....................................................................................... 9
vehicle.
3.8 Notification bar............................................................................... 9
•• Pay more attention to the ECU and the sensors when the operation 3.9 Customize your desktop............................................................... 10
is next to them.
3.9.1 Move items on the desktop................................................. 10
•• Ground yourself when you disassemble PROM, otherwise ECU
3.9.2 Delete items from the desktop............................................. 10
and sensors will be damaged by static electricity.
3.9.3 Change your wallpaper....................................................... 10
•• Do connect ECU harness connector firmly, otherwise electronic
3.9.4 Adjust brightness................................................................. 10
elements, such as IC inside ECU, will be damaged.
3.9.5 Set standby time.................................................................. 10
3.9.6 Set screen lock.................................................................... 10

III
LAUNCH X-431 PADII User's Manual

3.9.7 Adjust the volume................................................................ 10 5.8.3 Firmware Fix........................................................................ 22


3.10 Input Method.............................................................................. 10 5.8.4 My Report............................................................................ 23
3.10.1 Activate / hide on-screen keyboard .................................. 10 5.8.5 Profile.................................................................................. 23
3.10.2 Edit text..............................................................................11 5.8.6 Modify Password................................................................. 23
3.10.3 Android input method.........................................................11 5.8.7 Help..................................................................................... 23
4 Wi-Fi Setting................................................................................... 12 5.8.8 Log Out................................................................................ 23
5 How to diagnose............................................................................ 12 5.9 Settings........................................................................................ 23
5.1 Connections................................................................................. 12 5.9.1 System of Units................................................................... 23
5.1.1 Preparation.......................................................................... 12 5.9.2 Expiration Reminder............................................................ 23
5.1.2 DLC Location....................................................................... 12 5.9.3 Print Information.................................................................. 23
5.1.3 Vehicle Connection.............................................................. 13 5.9.4 Diagnostic Feedback........................................................... 23
5.2 Bluetooth Setting.......................................................................... 14 5.9.5 Network Detection............................................................... 23
5.3 Diagnosis Flowchart..................................................................... 14 5.9.6 Diagnostic Software Clear................................................... 23
5.4 User Registration & Connector Activation.................................... 14 5.9.7 About................................................................................... 23
5.4.1 User registration.................................................................. 14 6 Sensorbox (Optional).................................................................... 24
5.4.2 Diagnostic software layout.................................................. 16 6.1 Product summary......................................................................... 24
5.4.3 Function menu..................................................................... 17 6.2 Structure and Accessories............................................................ 24
5.5 Download/ Update Diagnostic Software....................................... 17 6.2.1 Sensorbox structure............................................................ 24
5.6 Start Diagnosing........................................................................... 18 6.2.2 Sensorbox accessories ...................................................... 25
5.6.1 Read Trouble Code............................................................. 19 6.3 Sensor Simulation........................................................................ 25
5.6.2 Clear Trouble Code............................................................. 19 6.3.1 Connections........................................................................ 25
5.6.3 Read Data Stream............................................................... 19 6.3.2 Simulation test..................................................................... 25
5.6.4 Special Function.................................................................. 20 6.3.3 Precautions on checking vehicle sensor ............................ 28
5.7 golo............................................................................................... 20 6.4 Multimeter..................................................................................... 29
5.7.1 Register a golo official account........................................... 21 6.4.1 Main Menu........................................................................... 29
5.7.2 Assign a diagnostic device to a official account ................. 21 6.4.2 Test sample......................................................................... 30
5.7.3 Pre-bind a golo user............................................................ 21 7 Batterybox (Optional).................................................................... 31
5.7.4 Launch real-time remote diagnosis..................................... 22 7.1 Product Summary......................................................................... 31
5.8 Profile........................................................................................... 22 7.2 Test Environment.......................................................................... 31
5.8.1 My Connector...................................................................... 22 7.2.1 Test environment................................................................. 31
5.8.2 Activate Connector.............................................................. 22 7.2.2 Battery status and description............................................. 31

IV
LAUNCH X-431 PADII User's Manual

7.3 Batterybox Structure and Test Accessories.................................. 32 11.2.1 Open browser.................................................................... 43


7.3.1 Batterybox structure............................................................ 32 11.2.2 Download files................................................................... 43
7.3.2 Test accessories.................................................................. 32 11.2.3 Manage bookmarks........................................................... 43
7.4. Connections & Operations.......................................................... 32 11.2.4 Set homepage................................................................... 43
7.4.1 Connection.......................................................................... 32 11.2.5 Clear history....................................................................... 43
7.4.2 Inside the vehicle test.......................................................... 33 11.3 Using Bluetooth.......................................................................... 44
7.4.3 Outside the vehicle test....................................................... 34 11.3.1 Open Bluetooth.................................................................. 44
7.5 Precautions on battery test . ........................................................ 34 11.3.2 Allow other devices to search for X-431 PADII.................. 44
8 Oscilloscope(Optional)................................................................. 36 11.3.3 Search other devices and pair it with X-431 PADII............ 44
9 Borescope (Optional).................................................................... 36 11.3.4 Send file via Bluetooth....................................................... 44
10 X-431 HD Module (Optional)....................................................... 39 11.4 Camera....................................................................................... 44
10.1 Knowledge of X-431 HD Module................................................ 39 11.4.1 How to take a picture......................................................... 44
10.1.1 Features............................................................................ 39 11.4.2 How to record a video........................................................ 45
10.1.2 Ports and indicators of X-431 HD Module......................... 39 11.5 Gallery........................................................................................ 46
10.1.3 Technical Parameters........................................................ 40 11.5.1 Open gallery...................................................................... 46
10.2 Connections............................................................................... 40 11.5.2 View pictures or videos...................................................... 46
10.2.1 How to connect OBD II vehicle.......................................... 40 11.5.3 Edit photos......................................................................... 46
10.2.2 How to connect non-OBD II vehicle.................................. 40 11.6 Music.......................................................................................... 46
10.3 Download and Install X-431 HD Module App ............................ 41 11.7 Calendar..................................................................................... 46
10.4 Activate X-431 HD Module......................................................... 41 11.8 Alarms......................................................................................... 46
10.5 Download Diagnostic Software.................................................. 41 11.8.1 Add an alarm...................................................................... 46
10.6 How to diagnose......................................................................... 41 11.8.2 Delete an alarm................................................................. 47
11 Others........................................................................................... 42 11.8.3 Turn on/off alarm................................................................ 47
11.1 Email........................................................................................... 42 11.9 File Manager............................................................................... 47
11.1.1 Configure an email account............................................... 42 11.10 Applications............................................................................... 47
11.1.2 Send an email.................................................................... 42 11.10.1 Install applications........................................................... 47
11.1.3 View an email.................................................................... 42 11.10.2 View installed applications............................................... 47
11.1.4 Delete an email . ............................................................... 42 11.10.3 Uninstall applications....................................................... 47
11.1.5 Revise an account setting.................................................. 42 11.11 Set Date & Time........................................................................ 47
11.1.6 Delete an email account.................................................... 42 11.12 Clear Cache.............................................................................. 47
11.2 Browser....................................................................................... 43 Appendix - FAQ.................................................................................. 48

V
LAUNCH X-431 PADII User's Manual

1 Introduction efficiently.
D. golo IM: Configures X-431 PADII as an IM (Instant Messaging)
1.1 Product Profile tool, which enables technicians to exchange repair experience and
perform remote assistance more conveniently;
X-431 PADII is a new Android-based vehicle trouble diagnostic 222 Wi-Fi connection and Ethernet connection are supported;
device developed for internet applications. It inherits from LAUNCH’s 333 Web browser: Users can make online search and visit any website;
advanced diagnosing technology and is characterized by covering a
444 HDMI interface is provided for connecting the external projectors or
wide range of vehicles, featuring powerful functions, and providing
displays;
precise test result.
555 Equipped with USB port for connecting USB devices and other
Through the Bluetooth communication between vehicle diagnostic add-on modules such as Scopebox, Sensorbox and Batterybox;
connector and variant mobile intelligent terminals, it achieves X-431
666 Other Android-based applications can be customized to install or
series full car model and full system vehicle trouble diagnosis, which
uninstall;
include Reading DTCs, Clearing DTCs, Reading Data Stream,
Actuation Test and Special Functions. 777 File Manager: Lets you manage files or downloaded files stored in
SD card efficiently;
Meanwhile, taking advantage of mobile internet, it integrates more
888 Settings: To configure your personalized X-431 PADII.
application and service, such as golo I/M program, Maintenance
Database and Update etc. 1.3 Technical Specifications
X-431 PADII adopts a higher performance-price ratio tablet, which is
equipped with Android 4.2 operating system, 1.2GHz quad core CPU A. X-431 PADII Tablet
and 10.1” IPS screen display.
Item Description
1.2 Features Operating system Android 4.2
CPU Quad-core Processor, 1.2GHz
111 Diagnose:
Display 10.1 inch IPS touch screen with 1280 x
A. Diagnose: Diagnose the electronic control system of prevailing 800P resolution
vehicle models covering Asian, European, American and Chinese.
Diagnosis functions include: Read DTCs, Clear DTCs, Read Data Memory 2GB
Stream, Special Functions etc; Hard disk 32GB SSD
B. Repair Data: Built-in abundant maintenance database helps Connectivity •• Wi-Fi (802.11 b/g/n)
repair professionals diagnose and repair vehicles efficiently, •• USB: 2.0
accurately and profitably. •• Bluetooth 2.0
C. Update: Lets you update your diagnostic software more

1
LAUNCH X-431 PADII User's Manual

Camera Front-facing, 2.0 megapixel; Rear- 2 Knowledge of X-431 PADII


facing, 5.0 megapixel, AF with
Flashlight There are three main components to the X-431 PADII system:
Sensor Gravity Accelerometer •• X-431 PADII Tablet -- the central processor and monitor for the
system (For details, please refer to Chapter 2.1.)
Audio Input/Output •• Microphone
•• Speakers
•• 3.5mm stereo headset jack
Video Output HDMI (The following are supported:)
HDMI 480P 640*480 VGA (Default)
HDMI 720P 1280*720 WXGA
HDMI 1080I 60HZ 1920*1080 WUXGA
HDMI 1080P 1920*1080 WUXGA Fig. 2-1
Only HDMIs with P (stands for a refresh •• X-431 PADII Docking Station -- the platform for charging X-431
frequency of 60Hz) are supported. PADII tablet (For details, please refer to Chapter 2.2.)
Power and Battery 12000 mAh lithium-polymer battery
Charging via 5V DC power supply
Operating Temperature -10℃ ~ 55℃(14 ~131℉)
Storage Temperature -20℃ ~ 70℃(-4 ~158℉)

B. Diagnostic Connector

Item Description
Working temperature -10℃ ~ 55℃(14 ~131℉) Fig. 2-2
Storage temperature -20℃ ~ 70℃(-4 ~158℉) •• Diagnostic Connector -- the device for accessing vehicle data (For
Relative humidity 20% ~ 90% details, please refer to Chapter 2.3.)

Fig. 2-3
2
LAUNCH X-431 PADII User's Manual

2.1 X-431 PADII Tablet


Table 2-1 formulates interfaces and indicators of X-431
PADII tablet (front):

No. Name & Descriptions


1 Micro SD Card Slot -- To store the SD
card.
2 USB Port*1 (See Note1*)
3 Screen Lock/Power Button -- To turn the
tablet on/off with long press, or lock/wake
up the screen with short press.
4 Mini HDMI Port -- To connect to an
external projector or monitor with HDMI
interface.
5 Front Camera
6 golo Button -- For quick access to IM
(Instant Messaging) application.
7 Volume Buttons -- To adjust the volume.
8 Reset Button -- To reset X-431 PADII.
9 Headphone Jack
10 DC IN Port -- To connect the included
Fig. 2-4 X-431 PADII Tablet (front & side view) power adaptor.
11 Micro USB Port (See Note1*)
Notes: 12 Charging indicator*2 (See Note2*)
1. USB Port is reserved for add-on modules, and other USB devices use only. 13 IPS Touch Screen
Micro USB Port is reserved for Micro USB cable only.
14 Microphone
2. It illuminates red while X-431 PADII tablet is charging. Once charging is
finished, it will turn green. 15 Charging Slot -- To recharge X-431 PADII.

3
LAUNCH X-431 PADII User's Manual

Table 2-2 formulates parts of X-431 PADII tablet (rear):

No. Name & Descriptions


16 Rear Camera
17 Camera Flash
18 Audio Speaker
19 Battery

Fig. 2-5 X-431 PADII Tablet (rear view)

2.2 X-431 PADII Docking Station


Table 2-3 formulates ports of X-431 PADII docking station

No. Name & Descriptions


1 Charging Slot -- To charge the tablet.
2 Powered OBD16 Socket -- Plug the diagnostic
connector into this socket for demo experience
when the docking station is connected to the
AC outlet.
3 Power Interface -- To connect the power cord
to AC outlet for supplying powe to docking
station.
4 OBD16 Sockets Without Power Output -- For
Fig. 2-6 X-431 PADII Docking Station housing other idle diagnostic connectors.

4
LAUNCH X-431 PADII User's Manual

2.3 Diagnostic Connector software, testing connectors) may vary. Please consult from the local
agency or check the package list supplied with X-431 PADII together.
1 Table 2-5 -- X-431 PADII common accessories and descriptions

No. Name Qt. Picture


2

3 1 X-431 PADII Tablet 1

Fig. 2-7 Diagnostic Connector Diagnostic


2 1
Table 2-4 formulates ports and indicators of diagnostic connector: Connector
(To connect to vehicle’s DLC.)
No. Name & Descriptions
1 OBD-16 Diagnostic Connector -- To connect on vehicle’s
OBD2 DLC. 3 Docking Station 1
2 Power Indicator -- It lights up while the connector is
plugged into the vehicle’s DLC.
3 Communication Indicator -- It will flash once the
connector is communicating with X-431 PADII or it is being
reset. 4 Micro USB Cable 1
(To connect on PC for data
4 Micro USB Port -- To connect on PC for data transmission transmission or upgrade
or upgrade via USB cable. diagnostic connector)

2.4 X-431 PADII Accessory Checklist Cigarette Lighter


5 1
Common accessories for each X-431 PADII are same, but for different Cable (To obtain power supply from
destinations, the accessories of X-431 PADII (such as diagnostic vehicle’s cigarette lighter )

5
LAUNCH X-431 PADII User's Manual

6 Power Adaptor 1 10 OBD I Converter 1

(To convert 100~240V AC power (A converting cable for connecting


supply to 5V DC power supply.) non-16 pin connector.)

7 HDMI Cable 1
(To connect to an external Password
11 1
projector or monitor with HDMI Envelope
(A piece of paper bearing
interface.)
Product S/N and Activation
Code, which is required for your
registration.)

Battery Clamps Non-16pin


8 1 12 (Optional)
Cable Connector
(To provide power to the non-16
pin connector through connection
to the vehicle's battery.)

OBD II Extension
9 1
Cable
(To connect the diagnostic
connector for extension purpose.)

6
LAUNCH X-431 PADII User's Manual

3 Preparations
3.1 Charging X-431 PADII
Choose any one of the followings to charge your X-431 PADII:
A. Use the included 5V power adaptor: Connect one end of the power
adaptor to DC IN port of X-431 PADII, then connect the other end to
the AC outlet. Never use other similar adaptors to charge X-431
PADII.
B. Use the docking station: Follow the steps described as below to
charge your X-431 PADII: Fig. 3-3
111 Locate the charging slot on the bottom of X-431 PADII tablet and 333 Insert one end of the included power cord of the docking station
the docking station. See Fig. 3-1 & Fig. 3-2. into the power jack, then plug the other end into the AC outlet. If
appears on the screen, it indicates it is being charged.
444 If the logo changes into , it indicates that the battery is fully
charged. Disconnect the docking station from the AC outlet.

3.2 On Using Your Battery


•• If the battery keeps unused for a long time or battery is completely
discharged, it is normal in case it can not be turned on while being
charged. Please charge it for a period and then turn it on.
Fig. 3-1 Fig. 3-2 •• Please use the included power adaptor to charge your X-431
222 Align the charging slots, and then dock the tablet into the station to PADII. We assume no responsibility for damage or loss resulting
ensure that it firmly sits on the docking station. Refer to Fig. 3-3. from using other similar adaptors other than the specified one.
•• The charging time of battery varies with temperature condition and
battery consumption status.
•• While X-431 PADII has low battery, a beep will sound. If it is very
low, X-431 PADII will be switched off automatically.

7
LAUNCH X-431 PADII User's Manual

3.3 Power On / Power Off X-431 PADII 3.5 Lock / Unlock the screen
3.3.1 Power on Many screen lock modes are available on X-431 PADII. Take the
preset screen-lock mode as example for demonstration.
Press the POWER key to turn on X-431 PADII.
Note: If it is the first time you use X-431 PADII or X-431 PADII 3.5.1 Lock the screen
keeps idle for a long time, X-431 PADII could fail to be turned on. It •• When X-431 PADII is ON, press POWER key once to lock the
results from low battery. In this case, please recharge your X-431 screen;
PADII for a while and try to turn it on. •• The system will lock the screen automatically after X-431 PADII
remains idle over the preset standby time.
3.3.2 Power off
3.5.2 Unlock the screen
111 Press the POWER key, an option menu will pop up on the screen.
222 Tap “Power off” to turn off X-431 PADII. Press POWER key to activate the screen, and then drag the lock to
“Unlock” position.
3.4 Tips On Finger Operations
Notes:
Actions Results 1. In case you forgot the screen lock, please refer to Appendix - FAQ
for details. You are not suggested to use the screen lock.
Single-tap To select a item or launch a program.
2. If you use unlock pattern, you have to draw the right target pattern
To zoom in so that the text on a webpage appears to unlock it.
Double-tap
in a column that fits your device’s screen.
Press and hold on the current interface or area
Long press until a contextual menu pops up on the screen,
and then release it
Slide To jump to different pages.
Drag Tap the desktop icon and drop it to other location.
To zoom in manually, place two fingers on the
Spread apart / screen and then spread them apart. To zoom out,
Pinch together place two fingers apart on the screen and then
pinch them together.

8
LAUNCH X-431 PADII User's Manual

3.6 Screen Layout 7 Display the widget and application icons.


8 It shows: System time, Wi-Fi connection status and signal
strength, battery status and other information. Tap the digital
clock to open the notice panel.

3.7 Status Bar


7 For some common indicators, please see the following table.

Icons Definitions Icons Definitions


1
2 Airplane mode Bluetooth is on
3
4 8 Positioning GPS Charging
5
6 Battery is fully charged Low battery

Fig. 3-4 New mail Preparing SD card


On-screen keys and status bar are as follows: Uploading Downloading
1 shows whether the diagnostic connector is properly Connected to a PC USB bound is activated
connected or not.
Available Wi-Fi is
2 Tap to display a list of applications that are currently Connected to Wi-Fi
detected
running or recently used. To open an application, tap it. To
remove an application, swipe it upwards. Notes: When the icon appears on the status bar, please charge
3 Tap to jump to the Android System’s home screen. it immediately.
4 Tap to return to the previous screen or exit the application.
3.8 Notification bar
5 Tap to capture the current screen and all captured
The notification bar is used to display some activities, such as new
screenshots are stored in the Screenshots folder.
messages, to do list and running tasks. You can also open the
6 Tap to configure the X-431 PADII system settings. notification bar to view the reminder or activity notification.

9
LAUNCH X-431 PADII User's Manual

3.9 Customize your desktop 3.9.5 Set standby time


If no activities are made within the defined standby period, the screen
3.9.1 Move items on the desktop
will be locked automatically and the system enters sleep mode to save
111 Tap and hold the item to be moved until it is shaken. power.
222 Drag and drop it to the target location. 111 On the main menu screen, tap Settings > Display > Sleep.
Note: Drag the icon to the margin of the screen and keep it still, 222 Choose the desired sleep time.
the system will switch to other extension desktop, place it to the
3.9.6 Set screen lock
desired location.
This function is designed to lock the screen and buttons to avoid
3.9.2 Delete items from the desktop accidental operations while X-431 PADII keeps unattended.
111 Tap and hold the item to be moved until it is shaken. 111 On the main menu screen, tap Settings > Security > Screen lock.
222 Drag it on the trash icon, then release it. 222 Choose the desired screen lock mode and follow the on-screen
instructions to finish your setting.
Warning: Deleting an icon will uninstall the corresponding
Note: You are recommended to set screen lock as “None”. In case
application. Please be careful to do so.
you forgot the screen lock, please refer to Appendix - FAQ for details.
3.9.3 Change your wallpaper
3.9.7 Adjust the volume
111 Tap and hold a blank area on the desktop, a pop-up wallpaper
window will be shown on the screen. This option enables you to adjust the volume of the ringtones, media
222 Set different wallpaper as desired: player, alarm and notice.

• Wallpapers: Choose a still picture from gallery as wallpaper. 111 On the main menu screen, tap Settings > Sound > Volume.
• L ive Wallpapers: Open it to choose one of the preset live 222 Drag the slider to adjust it.
wallpapers as wallpaper. Note: Alternatively, you can also press the volume keys to control
• Gallery: Set the photos you captured as wallpaper. the volume of the current application.
3.9.4 Adjust brightness
3.10 Input Method
Tips: Reducing the brightness of the screen is helpful to save the
power of X-431 PADII.
3.10.1 Activate / hide on-screen keyboard
111 On the main menu screen, tap Settings > Display > Brightness. By default, Android keybaord is available on X-431 PADII.
222 Drag the slider to adjust it as desired.

10
LAUNCH X-431 PADII User's Manual

•• To input text, tap the input box and the on-screen keyboard will be
4 To bring up an input options menu. Input languages and
activated automatically.
Android keyboard settings such as auto-capitalization and
•• After inputting, tap to hide the keyboard. sound on keypress are available.
Note: In some applications, the on-screen keyboard may appear 5 To enter a space.
over some interfaces partially. Close it to view more so that you can 6 Line feed.
decide what to do next.
7 > To delete the character before the cursor.
3.10.2 Edit text > Long-press this key to delete all characters before the
cursor.
Cut, copy and paste operations are supported.
111 Tap and hold the desired text area until a blue cursor appears. Note: For different input box, keyboard layout may vary. The figure
222 Press and drag the cursor to highlight the text to be edited.
shown as above is provided for reference purpose.
333 Tap SELECT ALL, CUT or COPY to perform the corresponding
operations. To delete the selected text, tap the delete key on the
keyboard.

3.10.3 Android input method

1 7
2 6
3

4 5

Fig. 3-5

1 To jump to next textbox.


2 To switch to numeric & symbol keyboard.
3 To toggle between upper case and lower case.

11
LAUNCH X-431 PADII User's Manual

4 Wi-Fi Setting 5 How to diagnose


Note: Once Wi-Fi is set as ON, X-431 PADII will consume more
5.1 Connections
power. While Wi-Fi keeps unused, please set it off to save power.
111 On the main menu screen, tap Settings > Wi-Fi. 5.1.1 Preparation
Normal testing conditions
•• Turn on the vehicle power supply.
•• Vehicle battery voltage range should be 9-14V and working voltage
of X-431 PADII is 5V.
•• Throttle should be closed at its close position.
•• Ignition timing and idle speed should be within specified range;
water and transmission oil temperature are within normal working
range (water temperature is 90-110℃ and transmission oil
temperature is 50-80℃).
Select testing connectors
If X-431 PADII is testing vehicles equipped with universal OBD II 16
Fig. 4-1 PIN diagnostic socket, please use the included diagnostic connector.
(For vehicles with non-OBD II 16 PIN diagnostic socket, a non-16 PIN
222 Tap or slide the Wi-Fi switch to ON, X-431 PADII starts searching connector is required.)
all available wireless LANs.
333 Choose the desired Wi-Fi, 5.1.2 DLC Location
•• If the network you chose is open, you can connect on it directly; The DLC (Data Link Connector or Diagnostic Link Connector) is the
•• If the selected network is encrypted and secured with WPA, you standardized 16-cavity connector where diagnostic code readers
have to input the right access password to connect. interface with the vehicle’s on-board computer. The DLC is usually
located 12 inches from the center of the instrument panel (dash), under
Once it is connected successfully, tap the Wi-Fi from the list to view its or around the driver’s side for most vehicles. If Data Link Connector is
name, link speed, security type, IP address etc. not located under dashboard, a label should be there telling location.
When X-431 PADII is in range of the WLAN, it will connect to the For some Asian and European vehicles, the DLC is located behind the
previously linked network automatically. ashtray and the ashtray must be removed to access the connector. If
the DLC cannot be found, refer to the vehicle’s service manual for the

12
LAUNCH X-431 PADII User's Manual

location. to DC IN port of X-431 PADII tablet, and the other end to AC


outlet.
B. Internal battery pack: For details on how to recharge X-431
PADII, see “Chapter 3.1 Charging X-431 PADII”.
For non-OBDII vehicle, proceed as follows:
111 Locate vehicle’s DLC socket.
222 Select the corresponding non-16pin connector.
333 Plug the non-16pin end of the connector into the DLC socket, then
connect the other end to the OBD I converter, and then tighten the
captive screws.
Near the center 444 Connect the other end of the converter to the included diagnostic
of dashboard connector.
Fig. 5-1 555 To supply power to OBD I converter from:
A. Cigarette Lighter: Connect one end of the cigarette lighter cable
5.1.3 Vehicle Connection to vehicle’s cigarette lighter receptacle, and the other end to the
The method used to connect the diagnostic connector to a vehicle’s power jack of OBD I converter.
DLC depends on the vehicle’s configuration as follows:
•• A vehicle equipped with an OBD II management system supplies
both communication and 12V power through a standardized DLC.
•• A vehicle not equipped with an OBD II management system
supplies communication through a DLC connection, and in some
cases supplies 12V power through the cigarette lighter receptacle
or a connection to the vehicle battery.
Follow the steps mentioned below to connect OBD II vehicle:
111 Locate vehicle’s DLC socket.
222 Plug the diagnostic connector into the vehicle’s DLC socket (It Fig. 5-2
is suggested to use the OBD II extension cable to connect the B. Battery Clamps Cable: Connect one end of the battery clamps
diagnostic connector and DLC socket.). cable to vehicle’s battery, and the other end to the power jack of
333 Choose one of the two ways to obtain power from: OBD I converter.
A. Power adaptor: Connect one end of the included power adaptor

13
LAUNCH X-431 PADII User's Manual

Fig. 5-3

5.2 Bluetooth Setting


Enter X-431 PADII Bluetooth setting screen (“Settings” --> “WIRELESS
& NETWORK” --> “Bluetooth”), slide the Bluetooth switch to ON and
X-431 PADII will start searching available Bluetooth device, tap the
desired connector to pair and match.
By default, the Bluetooth name is 98429*****00 (where ***** stands for
5 digits.).
Note: In case no Bluetooth setting is done before diagnostic
software is launched, you can also configure it while using the
software. For details on Bluetooth connection, please refer to “Chapter
5.6 Start diagnosing”.
Fig. 5-4
5.3 Diagnosis Flowchart
5.4 User Registration & Connector Activation
For new users, please follow the operation chart shown in Fig. 5-4 to
get familiar with and start using X-431 PADII.
5.4.1 User registration
Tap the icon on the desktop to launch the application, and then tap
“Login” to enter the login interface of diagnosis software, as indicated
in Fig. 5-5.

14
LAUNCH X-431 PADII User's Manual

In Fig. 5-7, input the Serial Number and Activation Code, which can be
found in the password envelope.

Product S/N

Fig. 5-5
Activation Code
1. If you are a new user, tap “New Register” to enter registration page.
See Fig. 5-6.

Fig. 5-8
Note: To exit and activate it later, tap “Skip”. In this case, you can
activate your connector by tapping “Activate Connector” in “Profile”.
For details, please refer to Chapter 5.8.2 Activate Connector.
Tap “Activate” to finish your registration. See Fig. 5-9.

Fig. 5-6
In Fig. 5-6, fill in the information in each field (Items with * must be
filled). After inputting, tap “Register”, a screen similar to the following
will appear:

Fig. 5-9
To download the diagnostic software, tap “Go To Update Center”. See
Fig. 5-10.
Tap “Download Later” to download and install it later. Refer to Chapter
5.5 Download/Update Diagnostic Software.

Fig. 5-7

15
LAUNCH X-431 PADII User's Manual

5.4.2 Diagnostic software layout


3
1 4

Fig. 5-10
2
In Fig. 5-10, tap “One-Click Update” to start downloading. It may
take several minutes to finish it, please be patient to wait. To pause Fig. 5-11
downloading, tap “Stop”; To resume it, tap “Continue”. If network
connection failure occurs, tap “Retry” to try again. 1 Tap to pull down all function menu. Refer to “Chapter
Once download is complete, the system will install the software 5.4.3 Function menu” for details.
package automatically. 2 Short-cut button bar: Refer to “Chapter 3.6 Screen Layout”
for detailed illustration.
2. If you have registered to be a member, input your name and
password in Fig. 5-5, and then tap the “LOGIN” button to enter the 3 Vehicle region buttons: Tap different buttons to switch to
main menu screen directly. corresponding vehicles.
4 Login button: Tap it to login or register the diagnostic system.
Once users have logged in successfully, it will change to your
user name.
5 Vehicle diagnosis software logo: To start diagnosing a
vehicle, you have to download the corresponding diagnostic
software.
For details on downloading/updating a software, please refer
to “Chapter 5.5 Download / Update Diagnostic Software”.

16
LAUNCH X-431 PADII User's Manual

5.4.3 Function menu 5.5 Download/ Update Diagnostic Software


Tap to unfold function menu, it mainly includes the following items: Before diagnosing a vehicle, you have to download the corresponding
vehicle diagnosis software.
Name Description
Tap , and then tap “Update” to select the paired diagnostic
Diagnostic Configures X-431 PADII to operate as
connector. Tap the serial number and a list of diagnostic software will
a diagnostic tool.
pop up on the screen.
Repair Data Provides a mass of service information
for various vehicle models, which
enables users to retrieve service data
online.
Update To update vehicle diagnostic software.
golo To launch golo IM (Instant Messaging)
application.
Chrome Launches the Chrome browser.
Camera Opens the camera.
Oscilloscope To d e t e r m i n e v e h i c l e e l e c t r i c a l
(Optional) equipment and circuit trouble.
Sensor To diagnose/simulate vehicle ECU Fig. 5-12
(Optional) sensor trouble.
Application By default, all diagnostic software is selected. To select certain
Multimeter To measure physical parameters such software, tap “Unselect”, and then uncheck the box next to car make.
(Optional) as voltage, resistance, frequency etc. Tap “One-Click Update” to start downloading.
Battery Test To test whether vehicle's battery is Once downloading is finished, the software packages will be installed
(Optional) good or not. automatically.
Borescope To check unseen or unreachable parts
Note: If applications of extending modules are downloaded, the
(Optional) or components.
system will decompress it automatically. In this case, tap it to install it.
To manage My Connector, My Report,
Profile Tap to return to the function selection screen.
Profile, Password and Logout etc.
Settings To configure system settings.

17
LAUNCH X-431 PADII User's Manual

5.6 Start Diagnosing 222 After Bluetooth is properly connected (no Bluetooth connection is
required for DEMO program), tap “Confirm” to start initializing. After
Tap on the main menu screen, and then choose “Diagnostic” to initializing is complete, the screen will display as below:
enter the vehicle selection page.
Take Demo as an example to demonstrate how to diagnose a vehicle.
111 Tap the “DEMO” logo to proceed to Step 2.

Fig. 5-14
333 Tap “Demo” to enter system selection interface. See Fig. 5-15.

Fig. 5-13
On-screen Buttons:
Vehicle Selection: Tap to return to the vehicle selection screen.
Print: Tap it to print the current screen. To perform printing, you need
to purchase a Wi-Fi printer manufactured by LAUNCH separately.
Search Bluetooth: Tap it to start searching all available Bluetooth
devices.
Confirm: Tap it to confirm and jump to the next step.
Note: Generally you have to match and pair Bluetooth while
diagnosing a certain vehicle. If paired successful, a pop-up message Fig. 5-15
“Connected to 98429*****00” will be shown.
444 Tap “Engine”, the system will jump to the function menu. See Fig.

18
LAUNCH X-431 PADII User's Manual

5-16. 5.6.2 Clear Trouble Code


Tap “Clear Trouble Code” function menu, the system will automatically
delete the currently existing trouble code.
Note: The trouble code will not disappear until the trouble was
completely cleared.

5.6.3 Read Data Stream


Tap “Read Data Stream” in function menu, the system will display data
stream items.

Fig. 5-16
To return to the previous screen, tap .

5.6.1 Read Trouble Code


Tap “Read Trouble Code” in function menu, the screen will display the
diagnostic result.
On-screen Buttons:
Vehicle Selection: Tap it to return to the vehicle selection screen. Fig. 5-17
Search: Tap it to search the definition of the selected DTC online.
Report: To save the current data in text format. On-screen Buttons:
Print: Tap it to print the current screen. To perform printing, you need Select Page: Tap it to select all items of the current page.
to purchase a Wi-Fi printer manufactured by LAUNCH separately. Unselect: Tap it to deselect all data stream items.
Help: Tap it to view the help information. Vehicle Selection: Tap it to return to the vehicle selection screen.
Print: Tap it to print the current screen. To perform printing, you need
Tap to return to the function selection screen.
to purchase a Wi-Fi printer manufactured by LAUNCH separately.
Confirm: Tap it to confirm and jump to the next step.

19
LAUNCH X-431 PADII User's Manual

After selecting the desired items, tap “Confirm” to enter the data Help: Tap to view the help information.
stream reading page.

Fig. 5-19
Fig. 5-18 Combine: Tap to display the selected waveform in combined form.
On data stream reading page, the following operations can be done: Please note that different items are highlighted in different colors.
If more than one page of data stream items is displayed, an icon Value: Tap to display the waveform in character form.
similar to appears. Swipe the screen from right to left to switch Record: Tap to start recording the running diagnostic data.
to the next page.
Tap to return to the function selection screen.
Vehicle Selection: Tap to return to the vehicle selection screen.
Graphic: After selecting, tap it to view the waveform. Refer to Fig. 5.6.4 Special Function
5-19. This option allows you to detect whether the system parameters are
Record: Tap to start recording diagnostic data for future playback normal or not. It mainly includes: Injector test, fuel pump test, purge
and analysis. The saved file follows the naming rule: It begins with control solenoid and so on.
vehicle type, and then the record starting time and ends with .x431 (To
Take “1# injector” as an example.
differentiate between files, please configure the accurate system time).
The file is stored in “My Report” under “Profile” menu. For details on To detect whether 1# injector works normally or not, tap “1# injector”,
playback operations, please refer to Chapter 5.8.4 “My Report”. the system will automatically carry out the function. After complete, a
To stop reading the data stream, tap “Stop recording” button (the blank prompt dialog box will pop up on the screen.
box next to recording progress bar).
Print: Tap to print the content of current screen. An additional Wi-Fi 5.7 golo
printer is required. This option aims to help repair shops or departments establish long-

20
LAUNCH X-431 PADII User's Manual

standing relationship with customers and technicians to increase


productivity and customer retention.
Tap “golo” to enter, the screen appears blank by default.

Fig. 5-20 Fig. 5-22


If a car user purchases a golo carcare connector and wants to bind a 444 Fill in required information, and then click Submit and wait for the
garage, tap “My Car” on mobile phone terminal to request for binding approval.
official account to be a registered customer.
Note: Please note that an official account is different from the user
As far as a garage is concerned, you need to use the golo Cloud to name of diagnostic tool. Make sure that golo users add the official
manage golo users. To log in the platform successfully, you have to account other than the user name while asking for registered or
apply for an official account which is formally authorized by LAUNCH. followed customers.
5.7.1 Register a golo official account 5.7.2 Assign a diagnostic device to a official account
111 Visit the golo Cloud website: http://ipublic.x431.com/. 111 Access to http://ipublic.x431.com/ and log in;
222 Click “Devices” in the navigation bar, and then click “Add device”;
333 Input the product S/N and password of the diagnostic device, and
then click “Save”.
Note: Several diagnostic tools can be assigned to an official account
since a garage may have many diagnostic devices.

5.7.3 Pre-bind a golo user


Except that a golo carcare user asks for to be a registered customer,
the garage who sold golo connectors can also adopt the golo Cloud to
Fig. 5-21 bind golo carcare users as regular customers.
222 Click “Apply now” at the upper right corner. Follow the steps described as below to proceed:
333 Input X-431 PADII account and password, and click “Apply for an 111 Log in http://ipublic.x431.com/;
account”. 222 Click “golo Clients” in the navigation bar;

21
LAUNCH X-431 PADII User's Manual

333 Click “Add golo users” and input the S/N and Password of golo diagnostic devices associated with the official account.
carcare connector in the pop-up dialog box and then click “Save” to For scheduled customers, tap the desired one to handle the remote
add it. request.
Note: If a car owner purchases a golo carcare connector that is pre- Tap the input field and use the on-screen keyboard to enter the text
bound to the garage, just input the S/N of the connector to activate it.
message, and then tap “Send” to send it; tap to send the voice
444 Click “Assign service technician” to appoint a special technician to
message; tap and then choose the “Remote Diagnosis” from the
serve for this golo user. After finished, click “Save” to confirm your
pop-up window to launch a remote assistance.
settings.
Note: The pre-binding agreement is in effect for one year. During this
period, golo carcare user can not unbind to this garage on the mobile 5.8 Profile
phone terminal. This function allows users to manage personal information.
5.7.4 Launch real-time remote diagnosis
5.8.1 My Connector
After binding golo users, tap “golo”, all customers will be listed on the
This option is used to manage all your activated connectors.
screen in the following kinds.
If several diagnostic connectors are activated on this tool, a list of
Options Notes connectors will be displayed on the screen. Once you choose the
connector that belongs to other account, you have to log out, and then
Scheduled Customer It defines as the golo carcare users who
input the right account to continue.
made a reservation for remote assistance
to the garage. Before sending the remote 5.8.2 Activate Connector
request, this golo user must be the followed
customer. It is used to activate your diagnostic connector.
Input the Serial Number and Activation Code, and then tap “Activate”
Registered Customer Refers to the regular customers who are
to activate the connector.
bound to this garage.
For details on how to obtain Serial Number and Activation Code, tap
Followed Customer Refers to the golo carcare users who the link below to get help.
followed your official account.
5.8.3 Firmware Fix
Note: Followed customer only supports remote diagnosis request.
Use this item to upgrade and fix diagnostic firmware. During fixing,
For registered customer, it not only features remote diagnosis request,
please do not cut power or switch to other interfaces.
but also supports sending abnormal warnings or messages of
customer’s vehicle to the golo Cloud, which will be presented on the

22
LAUNCH X-431 PADII User's Manual

5.8.4 My Report 5.9.1 System of Units


This option is used to view the diagnostic report generated in process It is designed to set the measurement unit. Metric System and English
of vehicle diagnosis. Additionally, delete, send operations are also System are available.
supported.
Tap “My Report”, there are total 3 options available. 5.9.2 Expiration Reminder
If user records the running parameters while reading data stream, it All pre-installed diagnostic software is free to use for 30 days. Once it
will be saved as .x431 file and appear under Diagnostic Record tab. expires, it will be locked automatically and the system will prompt you
Remote Diagnostic Report lists all records generated in process of to activate your connector if the expiration reminder is ON.
remote diagnosis.
5.9.3 Print Information
In case the DTC result is saved on Read Trouble Code page, .txt files
This option lets you define your print information. It mainly includes
will be listed under Diagnostic Report tab.
Workshop, Address, Telephone, Fax and License Plate.
5.8.5 Profile After inputting, tap on “Save” to save it.

Use this item to view and configure personal information. 5.9.4 Diagnostic Feedback
5.8.6 Modify Password This item allows you to feedback your diagnostic problems to us for
analysis and troubleshooting.
This item allows you to modify your login password.
5.9.5 Network Detection
5.8.7 Help
It enables you to test whether the current network environment is good
Function Notes, FAQ, Quick Start Guide and User Manual are or not. It is normal that you may encounter a logout while testing.
included.
5.9.6 Diagnostic Software Clear
5.8.8 Log Out
If you have downloaded several versions of diagnostic software, you
This option allows you to logout the system. can use this option to clear the old versions and only retain the latest
To logout the current user ID, tap “Log Out”. versions.

5.9 Settings 5.9.7 About

It enables you to make some application settings and view software The software version information and disclaimer are included.
version information etc.

23
LAUNCH X-431 PADII User's Manual

6 Sensorbox (Optional) Multimeter

Parameters Scope
6.1 Product summary Precision ±5%
X-431 PADII provides an optional function of automotive sensor Voltage test Testing range DC-400V~+400V
simulation test. “Sensor” function is specially designed to diagnose
and simulate vehicle sensor faults quickly and conveniently, including Input impedance 10Mohm
“DC voltage simulation”, “Fixed frequency simulation”, “Predefined Resistance test Testing range 0~40Mohm
waveform simulation” and “Hand-painted waveform simulation”.
Frequency test Testing range 0~25KHz
Vehicle sensors are the signal input devices for electrical control
systems, which can transform all kinds of running parameters, such Input impedance 1000Gohm
as vehicle speed, coolant temperature, engine RPM, air flow, throttle Input voltage 1~12V
opening, etc., into the electronic signal for the vehicle computer who
can optimize the engine running status per the above-mentioned 6.2 Structure and Accessories
parameters to keep the engine working in a prime status.
Meanwhile, it integrates the functions of automobile multimeter, which 6.2.1 Sensorbox structure
enables users to perform voltage, resistance and frequency test. (The
function utilizes the same hardware device as the sensor module)
It features automotive sensor simulation test and multimeter test
function.
Sensorbox

Parameters Scope
Precision ±5%
Voltage range -5V~+5V
Max output current 70mA
Predefined frequency range 0~150Hz
Square-wave signal pulse frequency 0~15KHz Fig. 6-1 Structural diagram of Sensorbox
Square-wave signal duty ratio 10%~90% Table 6-1 shows the ports and indicators for X-431 PADII sensorbox

24
LAUNCH X-431 PADII User's Manual

No. Name Description 3 Multimeter probe


1 Data receiving indicator Indicator (green) for receiving data
4 Electronic control converting
from main unit.
cable 1
2 Data sending indicator Indicator (green) for sending data to
main unit.
5 Electronic control converting
3 Power indicator It keeps steady on (red) after cable 2
Sensorbox is powered on.
6 Electronic control converting
4 B type USB port Connect to main unit with USB cable cable 3
when it is applied as separated USB
device. 7 Electronic control converting
cable 4
5 Power connector Connect to power supply through the
power adaptor.
6.3 Sensor Simulation
6 COM Common terminal of multimeter
7 VΩHz Testing terminal of multimeter 6.3.1 Connections
111 Firstly, power on the main unit (Connect one end of the power
6.2.2 Sensorbox accessories adaptor into the DC IN port of X-431 PADII tablet, and the other
end to the AC outlet.);
X-431 PADII sensorbox accessories include sensor test cable, probe
etc. See Table 6-2. 222 Plug one end of the sensor test cable (black) into the “COM”
interface of the sensorbox, then connect the other end to the test
As the product configuration can be different, the accessories included probe or electronic control converting cable;
with the product may differ from the accessories listed on this manual.
Please see the packing list attached to the product for the detailed 333 Connect one end of the sensor test cable (red) into the “VΩHz”
accessories. interface of the sensorbox, and then connect the other end to the
test probe or electronic control converting cable.
Table 2-2 Accessory checklist
Note: Choose corresponding cables and test probes according to
No. Name Picture different terminals.
1 Sensor test cable 6.3.2 Simulation test
Simulation test enables users to exactly judge if the sensor is good or
2 Sensor probe
not to avoid replacing components blindly. For example, the trouble

25
LAUNCH X-431 PADII User's Manual

code indicates the fault is in water temperature sensor itself. But we or inputting the desired voltage based on the working characteristics of
need to confirm whether the fault results from water temperature sensor, tap the button, then the X-431 PADII will begin to output the
sensor or the connections between ECU and sensors, or ECU itself. simulation voltages. Please note the red probe is the output terminal
In this case, we can make full use of simulation test to input the signal of simulation voltage.
of simulating water temperature sensor, instead of water temperature
sensor, to the microcomputer. If the engine works better and the fault 2. Fixed frequency simulation
vanishes, the fault is in the water temperature sensor. If the fault This option enables you to simulate the square wave signal of pulse
still occurs, input the signal to the corresponding terminals of ECU. frequency of 0.1 ~ 15 kHz, amplitude range of -5V ~ +5V and duty
Consequently, if the fault disappears, the fault lies in the connection cycle 10% ~ 90%.
between water temperature sensor and ECU, otherwise, the fault In Fig. 6-2, tap “Fixed frequency simulation” to enter a screen similar
exists in ECU. to Fig. 6-3.
After all connections are properly made (refer to Chapter 6.3.1 for
details), power on your X-431 PADII, launch X-431 PADII application
and enter the function menu interface, then tap “Sensor” to enter the
test selection screen. See Fig. 6-2.

Fig.6-3
Tap the setting option tab, then tap “+” or “-” to adjust the output,After
setting, tap to perform the test.
Fig. 6-2 3. Predefined waveform simulation
1. DC voltage simulation X-431 PADII provides some common sensor waveforms which have
been predefined to facilitate users to simulate sensor signals. As long
In Fig. 6-2, tap [Current voltage], then tap “+” or “-” to adjust the output
as you call out the predefined waveform, then tap to start simulating
voltage value. Alternatively, user can also tap edit box, then use the
output of corresponding sensor waveform and no more parameter
on-screen keyboard to input the desired value directly. After selecting
settings of simulation waveform are required.

26
LAUNCH X-431 PADII User's Manual

In Fig. 6-3, tap “Predefined waveform simulation” to enter the screen HO2S: Heated Oxygen Sensor
shown as Fig. 6-4. IAT: Intake Air Temperature Sensor
MAF: Mass Air Flow Sensor
MAP: Manifold Absolute Pressure Sensor
TP: Throttle Position Sensor
VAF: Volume Air Flow Sensor
VSS: Vehicle Speed Sensor
For example, tap “ECT” – “Warm (NTC Thermistor)” in Fig. 6-5, the
right screen will display the waveform of the sensor. See Fig. 6-6.

Fig. 6-4
Here, tap button, a screen similar to Fig. 6-5 will appear.

Fig. 6-6
In Fig. 6-6, tap the waveform, then the pre-defined waveform has been
set. See Fig. 6-7.

Fig. 6-5
In Fig. 6-5, the left setting column stands for sensor types and the right
area displays waveform. The sensor types are explained as below:
ECT: Coolant Temperature Sensor
EVP: EGR Valve Position Sensor

27
LAUNCH X-431 PADII User's Manual

Fig. 6-7 Fig. 6-8


In Fig. 6-7, tap button to perform simulation test. Button descriptions:
4. Hand-painted waveform simulation [ ]: Save the current waveform.
This option offers great convenience for users to simulate special [ ]: Loads the previously saved hand-drawn waveform.
waveform or fault wave. Users only draw the shape of waveform which [ ]: Clear all hand-drawn waveform.
needs to be simulated in central drawing area, and then configure [ ]: Click to call out the predefined waveform for reference.
some parameters on the top, namely high level, low level, and cycle of
[ ]: Continues the following operation.
waveform, then tap , X-431 PADII will output a waveform as desired.

Warning: Just draw a complete periodic waveform (when it is 6.3.3 Precautions on checking vehicle sensor
outputted, the system will regard the waveform in the drawing area as •• Hold the connector when plugging or unplugging it. Do not pull the
a periodic one). Users should draw as large as wave in drawing zone cable for unplugging.
so that the system can sample more points to reduce tolerance. While •• At first check the fuse, fusible line and terminals. Then check others
drawing, just pay attention to the shape of waveform, high level, low after eliminating these faults.
level and period can be ignored, which can be set in the Configure •• When measuring voltage, the ignition switch should be on and the
option. battery voltage should not be less than 11V.
In Fig. 6-2, tap “Hand-painted waveform simulation”, a screen similar •• When measuring voltage, please shake the lead lightly in the
to Fig. 6-8 will appear. vertical and horizontal direction for more precision.
•• When checking whether there is open in the line, disconnect the
CEU and the relevant sensor at first, then measure the resistance

28
LAUNCH X-431 PADII User's Manual

among the ports of sensor in order to determine whether open-


circuit / contact fault exists or not.
•• When checking if there is a short in the line, please disconnect the
CEU and the relevant sensor, then measure the resistance value of
the ports between the connected port and the vehicle body. If the
resistance value is more than 1MΩ, no fault occurs.
•• Before disassembling the engine electrical control system cable,
cut off the power supply, that is, turn the ignition switch OFF and
disconnect the cables on the battery poles.
•• Contact the test probe and the two terminals/ the two leads to be
measured when measuring the voltage between the two terminals
or the two leads. Fig. 6-9
•• Contact the red test probe to the terminal/ the cable to be Click the desired test as shown on Fig. 6-9 to perform related test.
measured, and the black probe to the ground when measuring
The operation method on Resistance test and Frequency test is
voltage of one terminal/ one cable.
identical to that of Voltage test. Here just take Voltage test as an
•• When checking the continuity of the terminals, contacts and leads, example for demonstration.
the method for measuring their resistances can be used.
Tap “Voltage test”, a screen similar to Fig. 6-10 appears:
•• Check the faults in the terminals of the CEU to sensors, relays, etc.
•• There are two test probes in the testing wire. The black one is the
common signal terminal (signal GND); the red one is the input
terminal for voltage, resistance, and frequency test and output
terminal for simulation voltage, simulation frequency and oxygen
sensor. Please choose the correct probes to match the different
terminals.

6.4 Multimeter
6.4.1 Main Menu
Make sure X-431 PADII main unit and the sensorbox are properly
Fig. 6-10
connected (Refer to Chapter 6.3.1 Connections for details), power on
X-431 PADII and enter the function menu interface, tap “Multimeter” to The following operations can be done:
display the test menu. See Fig. 6-9. [ ]: Erases the currently displayed waveform and display it starting

29
LAUNCH X-431 PADII User's Manual

from the left. Independent testing:


[ ]: Reduces the range and zoom in the waveform. Unplug the wire connector of coolant temperature sensor, then remove
[ ]: Increase the range and zoom out the waveform. the sensor from the engine; place the sensor into a breaker with water
and heat the water, then use the “Resistance measurement” to test
[ ]: Starts or stops the testing process. the Resistance between two terminals of coolant temperature sensor
at different water temperature. Compared the measured value with the
6.4.2 Test sample
standard value, if the Resistance is not compliant with the standard,
Knock sensor testing then the coolant temperature sensor shall be replaced.
(1) Resistance test for knock sensor (2) Output signal voltage testing for coolant temperature sensor
Switch ignition “OFF”, unplug the wire connector of knock sensor, test After installing the coolant temperature sensor, plug the wire connector
the resistance between the wire terminal and the case of knock sensor of sensor, and then switch ignition ON, test the output signal voltage
with “Resistance test” function, it shall be ∞ (disconnected), and if it between the two terminals of wire connector. The tested voltage shall
is 0Ω(conductive), which means the knock sensor shall be replaced. be in inverse proportional with the coolant temperature. When the
For the magnetostriction knock sensor, it can also test the resistance harness of coolant temperature sensor is disconnected, the voltage
by the “Resistance measurement” function; the resistance shall be shall be about 5V if the ignition switch is ON.
compliant with the specified value (see specific service manual for the
detailed data), otherwise, the knock sensor shall be replaced.
(2) Checking for the output signal of knock sensor
Unplug the wire connector of knock sensor, check voltage between
knock sensor connector terminal and ground wire of knock, it should
be output pulse voltage; otherwise, the knock sensor shall be
replaced.
Coolant temperature sensor testing
(1) Resistance test for coolant temperature sensor
On vehicle testing:
Switch ignition “OFF” and unplug the wire connector of coolant
temperature sensor, then use the “Resistance measurement” to test
the Resistance between two terminals of sensor. The relationship
between the resistance and the temperature is in inversely proportion
(negative temperature coefficient), which shall be less than 1kΩ during
warming up.

30
LAUNCH X-431 PADII User's Manual

7 Batterybox (Optional) SAE Society of Automotive Engineers 100~1700

7.1 Product Summary 7.2 Test Environment


X-431 PADII provides an optional function of automotive battery 7.2.1 Test environment
test, which adopts the latest state-of-the-art conductance testing
Inside the vehicle test indicates that the battery connects to loading
technology in the world and can test vehicle’s battery status. Two
devices, such as engine, etc. After doing battery test, it can perform
testing environments (Inside the Vehicle and Outside the Vehicle)
charging system and actuation system test, which is proceeded as a
are available and applicable to battery test. In addition to battery test,
whole simultaneously. Charging system and actuation system test is
charging system and actuation system test can be done while Inside
not required but must not be performed before battery test. Because it
the Vehicle is selected.
is difficult for vehicle technicians to judge where is faulty exactly if they
It supports various battery standards and specifications, including have the faintest idea of battery’s status itself.
CCA, DIN, IEC, EN, JIS, SAE and GB etc. It is specifically designed
to help car owner, repair workshop, battery factory use battery test Outside the vehicle test indicates that the battery is disconnected
instrument properly and determine whether the battery is normal or from all loading devices on vehicles. Therefore, only battery test is
not. supported in this condition.
Battery test aims to check starting plumbic acid storage batteries for 7.2.2 Battery status and description
vehicles, ship, boats and aviations, etc. It can test all kinds of batteries There are mainly 5 states as follows:
complying with CCA, DIN, JIS, EN, GB and SA standards. For detailed
test standards, please refer to Table 7-1. No. States Descriptions
Table 7-1 Test standard 1 Good battery Indicates battery is normal.
Standard (Full name) Test capacity range 2 Replace battery Indicates that battery is aged or becomes
rejected, or battery life cycle approaches to
CCA Battery Council International 100~1700 be exhausted. In this case, battery voltage
DIN Deutsche Industry Normen 100~1200 appears to be normal, but battery itself is
not well, i.e. battery polarity board has been
JIS Japanese Industry Standard 26A17~245H52
completely vulcanized or aged. Please
EN Europe Norm 100~1700 replace battery immediately.
IEC National Electrical Commission 100~1200 3 Good-recharge Stands for low battery. The battery is good
GB Chinese National Standard 100~1200 itself.

31
LAUNCH X-431 PADII User's Manual

4 Charge-retest It is better for a few batteries to be fully 7.3.2 Test accessories


charged before testing in order to avoid
judging in error under special conditions.
5 Bad cell Indicates one of the battery cells is bad and
can not work normally, but for which one is
bad, it can’t be verified. In this case, battery
voltage is generally lower than 11V, mainly
resulting from internal circuitry damage, such Fig. 7-2 Kelvin clip
as short circuit, open circuit, dummy weld
etc.

7.3 Batterybox Structure and Test Accessories


7.3.1 Batterybox structure Fig. 7-3 A/B cable

7.4. Connections & Operations


7.4.1 Connection
Connect one end of the A/B cable to the B type USB terminal of the
batterybox, and then connect the other end to the USB port of X-431
PADII tablet. This connection applies to outside the vehicle test and
inside the vehicle.
Notes:
1. Wait about 10s and begin to communicate since the batterybox
needs to initialize after connection is complete, otherwise,
Fig.7-1 Batterybox structure diagram communication may fail.
2. Red lamp on the batterybox means it has been successfully
Battery connector: Connect to battery for battery test. powered up; If the green light is always on, it indicates the clip is
B type USB terminal: Connect to the X-431 PADII tablet with a USB well connected; while the green light blinks, it indicates that the
cable. clip has poor contact. Do not perform any test until the clip and A/B
cable are properly connected.

32
LAUNCH X-431 PADII User's Manual

7.4.2 Inside the vehicle test floating electricity has been removed, please turn off the headlamp
to continue the testing” will appear on the screen.
Battery test and charging system & actuation system test can be done
in this mode. 555 Follow the on-screen instructions to turn off the headlamp and
tap [OK], the system will continue the testing. Tap , it will enter
1. Battery test
testing standard selection screen. See Fig. 7-5.
Enter battery test main menu, and select a desired test environment
as shown in Fig. 7-4.

Fig. 7-5
666 Select a testing standard except for JIS and tap , a screen
Fig. 7-4 similar to Fig. 7-6 will appear. Users can adjust capacity size by
Notes: The sequences of inside the vehicle and outside the vehicle tapping on < or > or by dragging the slider on the bar.
test are almost the same, but under inside the vehicle condition, all
loads in vehicles must be powered off for getting an exact test value.
111 Firstly, the system detects whether floating electricity exists or not
before testing. If yes, turn on the headlamp to remove it. Otherwise,
the system starts test program directly.
222 Tap [Inside the vehicle], the system starts detecting floating
electricity automatically. If floating electricity is detected, it will
prompt you to turn on the headlamp.
333 Follow the on-screen instructions to turn on headlamp, the system
starts removing floating electricity.
444 Once the floating electricity is removed, a prompt message box “The Fig. 7-6

33
LAUNCH X-431 PADII User's Manual

If JIS is selected, tap , the system will enter Select testing


capacity screen. Users can select corresponding standard capacity
value according to battery model marked on battery.
777 Tap and the testing result will appear on the screen.
Fig. 7-8
After detecting engine starting, follow the instructions on the screen to
increase the speed.
The system begins to receive test data information after acceleration
was detected, as shown in Fig. 7-9.

Fig. 7-7 Fig. 7-9


[ ]: Tap it to perform the charging system and starting system test. Tap [OK], test data will be shown on the screen.
[ ]: Tap to test it again. Notes: It is unnecessary to perform charging system and start
[ ]: Tap it to reset the test. system test after finishing battery test, but battery test must be done
before undergoing charging system and starting system test.
2. Charging system and starting system test
While performing this test, the battery’s charging voltage value 7.4.3 Outside the vehicle test
and starting voltage can be obtained in case of engine starting and It only applies to battery test and detecting floating electricity will be
accelerating. Based on the data, the system will judge whether ignored while performing battery test.
battery’s charging and actuation status is normal or not.
On Fig. 7-4, tap [Outside the vehicle] to select battery test standard.
Tap in Fig. 7-7, a dialog box will pop up as Fig. 7-8. The following operation steps are identical to Steps 6 ~ 7 in Chapter
7.4.2 Battery test. Please refer to it for details.

7.5 Precautions on battery test


For the purpose of getting accurate test results, unless otherwise

34
LAUNCH X-431 PADII User's Manual

special required, all loads need to be power off such as headlamp, system will prompt you a message of “Engine has been speeded”
engine etc. before testing battery. It has no influence on test result in the event that engine’s output
The operating time required for charging system and actuation system voltage or engine revolution is not very stable. No matter whether
test varies from person to person. If the engine does not start or the vehicle is accelerated or not, the output voltage only differs within
accelerate within 30 seconds, the system will prompt you “receiving 0.2V.
timeout” and return to the initial status. While doing inside the vehicle test, Kelvin clip is always found to be
Whether Engine is off or not has no influence on charging and in poor contact. To remain it in good contact, please shake it several
actuation test result after increased speed is detected, but other loads times before testing. Take down the battery connector, and test it
need to be powered off. again, the value probably varies. The deviation may arise from battery
The accuracy of battery voltage, charging voltage, start voltage is connector.
0.01V in test results; CCA (Cold Cranking Amps) precision is 5CCA. Pay more attention to connect the clip. The battery poles connect
Generally, charging voltage value is greater than starting voltage. with conductor, which makes the clip has a poor connection when
Charging voltage range is as follows: 13.8--14.5V for domestic vehicle; testing battery. A tolerance of dozens of CCA occurs if the clip is out of
13.3--15.5V for imported vehicles. The voltage varies with different position, or oil, dust attaches on the pole. The gear and main body of
car models, so you have to judge based on related vehicle models. clip should be fully matched with battery poles.
In general, the DC voltage is stable, but it also varies with different Notes:
revolution speed.
111 Battery poles inside the vehicle are enveloped by connectors, which
Starting voltage range: The value higher than 9.6V is regular,
may produce some errors for test results. The tolerance results
otherwise it is too low. Due to different situations, whether the starting
from the resistance of connectors. The greater the resistance value
voltage is higher or not does not mean the vehicles or batteries are
is, the greater the tolerance becomes. But generally, the tolerance
faulty. For detailed faults, other special equipments are needed.
does not affect the test conclusion.
To validate the accuracy of the value, the best method is to collect
the signals of starting and charging voltage and observe it on an 222 Testing the battery separately generates an exact test result.
oscillometer. The battery box is a very useful auxiliary tool for quick test. If any
problems were found, test it separately for getting an exact test
Generally, the voltage is lower than 11V for the bad cell battery, but it
result.
is possible that the battery is completely exhausted or has a serious
low capacity. In this case, just recharge your battery. Bad cell always
happens when the loads on a stopping vehicle are turned on for a long
time.
Please note that it is normal for quick detecting of “Increase speed”
because it follows the theory of detecting “Increase speed”: If the
detected voltage is higher than the previous battery test voltage, the

35
LAUNCH X-431 PADII User's Manual

8 Oscilloscope(Optional) 9 Borescope (Optional)


Oscilloscope is an optional function of X-431 PADII, including 9.1 Introduction
automotive oscilloscope and automotive ignition waveform.
Automotive borescope is mainly applied to those unseen parts of
Automotive oscilloscope can make the auto repair technician quickly
engine, fuel tank, braking system.
judged the faults on automotive electronic equipment and wiring, and
the oscilloscope sweep speed is far greater than the signal frequency While testing a vehicle system, engine is one of the main parts to
of such vehicles, usually 5-10 times of the measured signal. The be checked. To check if the internal of a engine is qualified or not or
automotive oscilloscope not only can quickly capture the circuit signal, whether internal carbon deposit and damage exists in the engine or
but also can slowly display the waveform to observe and analyze. It not, we can make full use of a borescope to solve these quesitons.
can also record and store the tested signal waveform which can be X-431 PADII provides an optional function of borescope.
played back to observe for the fast signal, having great convenience The borescope is mainly composed of an inspection camera, flexible
to failure analysis. Either high-speed signal (e.g.: Injection nozzle, tube and USB cable. The water-resistant camera lens with adjustable
intermittent fault signal) or the slow-speed signal (e.g. the throttle LED lights enables you to observe the parts that can not be seen in
position change and the oxygen sensor signal) can be observed wet, dark, fluid soaked places. The included flexible tube is convenient
through automotive oscilloscope in an appropriate waveform. for easy inspection and allows for access to hard-to-reach areas.
The electronic signal can be compared and judged via measuring five In addition, the captured pictures and videos also provide you intuitive
parameters indexes. The five parameters indexes are the amplitude data for easy analysis.
(the maximum voltage of signal), the frequency (the cycle time of
signal), the shape (the appearance of signal), the pulse width (the
duty cycle or the time range of signal), and the array (the repetition
characteristic of signal), which can be tested, displayed, saved by the
automotive oscilloscope. Via the waveform analysis can further detect
the circuit fault on sensors, actuators, circuits, and electronic control
units, etc.
Refer to the Android-based Scopebox User’s Manual included with the
Scopebox for detailed operations.

36
LAUNCH X-431 PADII User's Manual

9.2 About Endoscope 4 Handle

5 Camera with 4 adjustable LED lights: The camera head


is water-resistant and is where you can attach the useful
1
optional accessories (magnet, mirror, hook) add-on.
2 USB cable: Connect it to LAUNCH diagnostic tool for viewing
6
what the camera captures.
3

4 9.3 Technical Parameters


5
Resolution 640 x 800 pixel (VGA)
6 Frame Rate 30fps (pictures/sec)
Image Sensor 1/12" CMOS
White Balance Automatic
Fig. 9-1 Exposure Automatic
Light Source 4 adjustable LEDs
1 Snapshot button: To take a snapshot of the current view
and save it to your LAUNCH diagnostic tool as an image. USB Port USB1.1/2.0/3.0

2 Flexible tube: You can bend the neck to get in to hard-to- Power Supply 5V via USB
reach places and even if it is not straight, it can still give you
pictures of what the camera is looking at. (Note: Do NOT Ambient temperature 0 to +65oC
force it too hard while bending the neck into strange shapes.) USB Cable Length Approx. 2000mm
3 Dial for LED light brightness: There are 4 LED lights in the Probe & Camera Length 1030mm
lens that act like a torch to illuminate dark spots where the
camera can not see well. This dial allows you to adjust the Probe Cable Length 830mm
light brightness.
Min. Bending Radius 50mm

37
LAUNCH X-431 PADII User's Manual

Alternatively, you can also press the Snapshot button on the X-431
Lens Diameter 7.0mm
PADII to take photos.
Probe Tube Diameter 6.0mm To record a video, switch from Camera mode to Video mode and
tap Record button on the screen to start recording.
Viewable Angle 60o
Images are captured in .jpg format and videos are recorded in .avi or
Lens Focal Length More than 50mm .mp4 format. All photographings and videos are saved in DCIM folder
where users can browse and replay it.
Net Weight Approx. 270g

9.4 Connections & Operations


111 Locate the USB port of X-431 PADII.
222 Insert the USB cable into the USB port of X-431 PADII.


Fig. 9-2
333 Bend the neck of the flexible tube as desired and extend the
camera with adjustable LED lights to some unseen or unreachable
parts of engine, hydraulic system, nozzles etc.
444 After connections are properly made, press the [POWER] button
on X-431 PADII to turn it on. Wait until the system enters the main
menu, tap . Tap and select [Borescope] to run it, then the
screen will display the scene captured from the borescope camera.
555 Adjust it until the lens stops in the desired place, then use the dial
for LED light brightness to adjust the brightness.
666 Press the Snapshot button on the borescope to take a photo.

38
LAUNCH X-431 PADII User's Manual

10 X-431 HD Module (Optional) Fig. 10-1 Ports and indicators of X-431 HD module

X-431 PADII provides an optional function of X-431 Heavy-duty No. Name Notes
module, which is specifically designed to diagnose diesel and gas- 1 Indicators (from left
fueled heavy-duty vehicle models of 12V & 24V voltage. to right)

10.1 Knowledge of X-431 HD Module Power indicator It lights up when X-431 HD module is
powered up.
10.1.1 Features
Communication It lights up when X-431 HD module is
111 Applicable to diesel vehicle of 12V & 24V voltage; no need for indicator of X-431 communicating with X-431 PADII.
battery conversion when testing 24V trucks; PADII
222 Supports a wide range of vehicle models covering Asian, Communication It lights up when X-431 HD module is
American and European etc; indicator of Vehicle connected to vehicle’s DLC.
333 Powerful testing function enables you to diagnose all electronic
control system; Communication It illuminates when X-431 HD module
indicator of PC is connected to COM port of a
444 International design to adapt to all diagnostic sockets.
PC(Currently disabled).
10.1.2 Ports and indicators of X-431 HD Module USB status It illuminates blue after USB cable
indicator is properly connected to X-431 HD
module(Currently disabled).
Bluetooth indicator It lights up when X-431 HD module is
communicating with vehicle’s DLC.
2 PC communication To connect to the serial port of PC
port (Currently disabled).
3 USB port To connect the B-shaped terminal of
USB cable (Currently disabled).
4 Diagnostic socket To connect the main cable.
5 Power interface To connect the power adaptor of
X-431 HD module.

39
LAUNCH X-431 PADII User's Manual

10.1.3 Technical Parameters


•• Working voltage: 9~36V
•• Working temperature: -20℃ ~ 70℃
•• Storage temperature: -30℃ ~ 80℃
•• Relative humidity: 10% ~ 80%
•• Dimension: 110 mm * 178 mm * 50 mm

10.2 Connections
10.2.1 How to connect OBD II vehicle
Follow the steps described below to proceed:
111 Locate vehicle’s DLC socket. The DLC is usually located the
driver’s cab. If the DLC cannot be found, refer to the vehicle’s
service manual for the location.
222 Connect one end of the main cable to the diagnostic socket, and 2. Via Battery Clamps Cable
then connect other end to the vehicle’s DLC (For non-16 pin DLC,
you need to choose the corresponding diagnostic connector). See
Fig. 10-2.

Fig. 10-2

10.2.2 How to connect non-OBD II vehicle


Choose one of the following to connect non-OBD II vehicle:
1. Via Cigarette Lighter

40
LAUNCH X-431 PADII User's Manual

10.3 Download and Install X-431 HD Module App 10.6 How to diagnose
111 Visit the LAUNCH website and download the application Diagnosing a heavy-duty truck has same operation procedures
corresponding to X-431 HD module; as DEMO program. For details, please refer to Chapter 5.6 “Start
Note: If downloading using X-431 PADII, please make sure Wi-Fi has Diagnosing”.
good or strong signals.
2. Follow the on-screen instructions to install it. Once installation is
complete, an application icon will appear on the HOME screen.

10.4 Activate X-431 HD Module


After purchasing X-431 HD module, you have to activate it before use.
Follow the steps below to proceed:
111 Launch the application, and tap to enter;
222 Tap “Profile” from the pull-down menu, and then tap “Activate
Connector”;
333 Input the Serial Number and Activation Code, which can be found
in the included password envelope. Tap “Activate”.

10.5 Download Diagnostic Software


Before diagnosing heavy-duty trucks, you have to download the
diagnostic software.
111 Tap and then tap “Profile” to enter. Choose the serial number for
X-431 HD module;
222 Tap and then tap “Update” to enter diagnostic software
download interface;
333 Tap “Select All” to select all, and then tap “One-Click Update” to
start downloading and installing.
Note: Tap the triangle next to the software version to view all available
versions. To deselect the desired one, just uncheck the box.

41
LAUNCH X-431 PADII User's Manual

11 Others 11.1.3 View an email


111 Enter main menu screen, and tap Email to enter account screen.
11.1 Email 222 Tap the desired email account.
333 Tap the desired one to read:
This function allows you to send and receive email. You can add POP3
or IMAP email account for some common web email service provider. Note: For different networks, inbox may have some delays. Tap
on the upper right corner to refresh the email list.
11.1.1 Configure an email account
Note: Before sending or receiving email, you have to set up an 11.1.4 Delete an email
email account. In addition, this function required a stable network 111 Enter main menu screen, and tap Email to enter account screen.
connection. 222 Tap the desired account, and then select the mail to be deleted.
111 On the desktop, tap Email. 333 Tap to delete.
222 Input email address and password, tap “Next” or “Manual setup”.
Note: To delete multiple emails, check the box before the message
Note: If “Manual setup” is selected, please consult your email
and then tap . Once “Messages deleted” appear, it indicated the
service provider for detailed parameter setting.
selected messages has been removed successfully.
333 Choose the desired email account type to enter the incoming
settings screen, tap “Next”. 11.1.5 Revise an account setting
444 Follow the on-screen instructions to proceed until the system 111 Enter main menu screen, and tap Email to enter account screen.
prompts you that the account setup has been finished.
222 Tap > Settings.
333 Choose the desired Email account from the account list.
11.1.2 Send an email
444 Follow the instructions on the screen to make general settings and
111 Enter main menu screen, and tap Email to enter account screen. If notification settings.
several email accounts are configured, choose the desired one.
Note: Never change the default settings of the server, otherwise
222 Tap to enter new mail writing interface. Input the receiver
email failure may occur.
address in “To” field and a title in “Subject” column, and then type in
the content in “Compose” email area.
11.1.6 Delete an email account
333 After inputting, tap , you can perform any one of the followings:
Attach file, add CC/BCC, save draft, discard and setting. Once Email account is removed, X-431 PADII stops receiving the
emails from this account, but all messages in it still keeps as it is.
444 Tap to send email.

42
LAUNCH X-431 PADII User's Manual

111 Enter main menu screen, and tap Email to enter account screen. 11.2.2 Download files
222 Tap > Settings. Files, pictures, and applications can be downloaded from the website
333 Choose the desired Email account from the account list. in browser.
444 Choose “Remove account” to delete it. For example:
Tap and hold a picture, then choose “Save image” from pop-up menu
11.2 Browser to download it.
To download a link, tap and hold it, and then choose “Save link”.
11.2.1 Open browser
To protect your X-431 PADII and personal data, please download
Enter main menu screen, tap Browser to launch the browser. You can applications from trusted sources. To configure it, tap Settings >
choose the desired homepage or input the website address to browse. Security, and then deselect the box next to Unknown sources.
1
8
11.2.3 Manage bookmarks
2
You can set the favorite website as bookmark for your quick access.
7
3 111 Enter main menu screen, tap Browser to launch the browser.
6
222 Tap to enter bookmarks page.
4 5
333 Long press it, you can share, open and delete the bookmark.
Fig. 11-1
11.2.4 Set homepage
1 Create a new tab. This option enables you to set commonly visited website as the
2 Close the current page. homepage. The homepage will be opened by default every time you
3 Refresh the current page. launch your browser.

4 Input a web address. 111 Enter main menu screen, tap Browser to launch the browser.

5 Add the current page as bookmark. 222 Tap > Settings > General.
6 Open search bar. 333 Tap “Set homepage”, then follow the on-screen instructions to finish
it.
7 Open bookmark list.
8 View more options. 11.2.5 Clear history
To prevent your personal information from being exposed much better,
you are strongly recommended to clear your browser navigation

43
LAUNCH X-431 PADII User's Manual

history. 444 Choose the desired one from the search result to pair it with X-431
111 Enter main menu screen, tap Browser to launch the browser. PADII.
222 Tap > Settings > Privacy & security. 11.3.4 Send file via Bluetooth
333 Tap “Clear history”. You can send pictures, videos, audio files or test reports to others for
sharing and review via Bluetooth.
11.3 Using Bluetooth
To transfer files via Bluetooth, please proceed with the following steps
Bluetooth connection is supported on X-431 PADII. Using it, you described below:
can connect X-431 PADII to other compatible devices for data 111 Enter main menu screen, and tap “File Manager”.
transmission.
222 Access the corresponding folder and choose the desired picture,
Note: Bluetooth connection is likely to be disturbed by other video or audio file.
objects, such as walls or other electronic devices. 333 Tap and choose “Bluetooth” from the pull-down menu.
444 Tap the target Bluetooth device you want to transmit files.
11.3.1 Open Bluetooth
111 Enter main menu screen, tap “Settings” --> “Bluetooth”. 11.4 Camera
222 When the Bluetooth switch is ON position, it indicates it is already
on and a corresponding Bluetooth icon will appear on the status bar 11.4.1 How to take a picture
of X-431 PADII. Enter main menu screen, tap Camera.
11.3.2 Allow other devices to search for X-431 PADII
111 Enter main menu screen, tap “Settings” --> “Bluetooth”. Tap and
choose “Visibility timeout”.
222 Set the desired visibility option.

11.3.3 Search other devices and pair it with X-431 PADII


Before transmitting data with other Bluetooth devices, you have to pair
it with X-431 PADII.
111 Check and ensure Bluetooth is ON.
222 Enter main menu screen, tap “Settings” --> “Bluetooth”.
333 X-431 PADII starts scanning all Bluetooth devices.

44
LAUNCH X-431 PADII User's Manual

11.4.2 How to record a video


8
1 In camera mode, drag the slider to video mode.

9
1
7
8
2
6 7
2

6
5
3
5
3
4

Fig. 11-2 4
Fig. 11-3
1 Drag the slider to toggle between camera and video mode.
2 Tap it to take a picture. 1 Drag the slider to toggle between camera and video mode.
2 Tap it to start recording a video.
3 Tap it to browse your pictures.
3 Tap it to play back your video.
4 To zoom in, place two fingers on the focus area and then
spread them apart; To zoom out, place two fingers apart 4 To zoom in, place two fingers on the focus area and then
and then pinch them together. spread them apart; To zoom out, place two fingers apart
and then pinch them together.
5 Set camera parameters, such as Exposure, White
balance, Picture size etc. 5 Tap it to make some video settings, including Fix time,
Exposure, Save location etc.
6 Tap it to select color effect.
6 Tap it to choose video size.
7 Tap it to turn on/off flash mode. 7 Tap it to set time lapse interval.
8 Tap to toggle between front camera and rear camera. 8 Tap it to set white balance.

45
LAUNCH X-431 PADII User's Manual

9 Tap to toggle between front camera and rear camera. 11.5.3 Edit photos
Without installing third-party photo processing software, X-431 PADII
provides powerful photo editing functions, such as light compensation,
11.5 Gallery red eye processing, crops etc.
This option is used to manage pictures and video files. 111 Open the picture to be edited in Gallery.
222 Tap the icons located on the bottom of the piture to perform the
11.5.1 Open gallery corresponding functions.
Enter the main menu screen, tap Gallery to open gallery, the system 333 Tap Save, the edited picture will also be saved in the same folder in
starts scanning all pictures and videos on X-431 PADII. which the original picture lies.

11.5.2 View pictures or videos


11.6 Music
111 Enter the main menu screen, tap Gallery to open gallery.
Enter main menu screen, and tap Music to enter. Music files are
222 Tap a picture or video file to view it in full screen mode. Swipe the
stored into 4 categories: Artists, Albums, Folders and Playlist.
screen to right or left to view the previous or next one.
111 Tap the desired music type. Open music file list.
To zoom in manually, place two fingers on the screen and then spread
222 Tap the desired audio files to start playing.
them apart. To zoom out, either double-tap again or place two fingers
apart on the screen and then pinch them together.
11.7 Calendar
Featuring gravity sensor, X-431 PADII will adjust the orientation of the
pictures automatically if it is rotated. This function lets you view calendar or create to-do events.

The following operations can be also done while browsing gallery: Enter main menu screen, tap Calendar. Tap the time in the upper left
corner to switch between Day, Week, Month and Agenda.
To play back pictures in the current folder.
11.8 Alarms
To launch camera.
11.8.1 Add an alarm
To share pictures or videos.
111 Enter main menu screen, tap Music.
To view more options. 222 Tap to enter new alarm setting interface.
333 Set the detailed items.
444 After setting, tap “OK” to confirm.

46
LAUNCH X-431 PADII User's Manual

11.8.2 Delete an alarm 222 Swipe the screen from right to left until ALL tab appears.
111 On alarm list screen, tap and hold the desired alarm. 333 Tap the desired one to view its detailed information.
222 Tap the , and then tap “OK” in the confirmation dialog box to 11.10.3 Uninstall applications
delete it.
To release storage space, you can uninstall some unused applications.
11.8.3 Turn on/off alarm 111 Tap Settings > Apps.
On alarm list screen, slide the switch to ON to activate it. To disable it, 222 Swipe the screen from right to left until ALL tab appears.
just switch it to OFF. 333 Tap the desired one to enter.
444 Tap “Uninstall” and then tap “OK” in the dialog box to start
11.9 File Manager uninstalling.
This option enables you to manage your files.
11.11 Set Date & Time
Tap File Manager, and then choose the desired folder to perform
corresponding operations. X-431 PADII is preset to use the network-provided date, time zone and
time.
11.10 Applications Note: If Automatic date & time is set as Use network-provided
11.10.1 Install applications time, date, time and time zone will not be defined.

To install an application, you need to download it first. All items 111 Enter the main menu screen, tap Settings > “Date & time”.
downloaded in default browser are saved in Downloads. 222 Deselect “Automatic date & time”.
111 On the main menu screen, tap Downloads. 333 Follow the on-screen instructions to set date, time and time zone.
222 Choose the desired .apk file.
11.12 Clear Cache
333 Tap “Install” to start installing the application.
444 Tap “Done” to finish it. Doing so will clear all browsing records and accounts and enables
X-431 PADII to run smoothly and quickly.
Note: In process of installation, a message prompting installation
111 Tap Settings > Apps.
prohibited may appear. Please read it carefully. To install it, please tap
“Settings” > “Security”, and check the box next to “Unknown sources”, 222 Tap and select “Sort by size” to arrange all applications in size
which allows you to install non-Market application. order.
333 Tap certain application, then tap “Clear Cache” to spare the space
11.10.2 View installed applications these cache files are occupied.
111 Tap Settings > Apps.

47
LAUNCH X-431 PADII User's Manual

Appendix - FAQ 222 Press and hold VOLUME - key and POWER key until X-431 PADII
enters system recovery mode;
333 Use the VOLUME + / VOLUME - key to move the highlight bar on
1. Whether can I use other similar adaptors to charge X-431 “wipe data / factory reset” and press POWER key to confirm;
PADII?.
444 Press VOLUME + / VOLUME - to select “yes” and press POWER
No. Please use the included 5V power adaptor or docking station to key to confirm;
charge your X-431 PADII. We assume no responsibility for damage 555 Select “reboot system now” and press POWER key to restart the
or loss resulting from using other similar adaptors other than the system;
specified one.
666 After resetting is complete, follow the on-screen instructions to
finish the system settings.
2. How to save power?
Warning: Resetting may cause data loss. Before doing so, please
•• Please turn off the screen while X-431 PADII keeps idle.
make sure important data has been backed up.
•• Set a shorter standby time.
•• Decrease the brightness of the screen. 5. How to do if the system runs slowly?
•• If Wi-Fi connection is not required, please turn it off. In this case, please do the followings:
•• Disable GPS function if GPS service is not in use. > Check all running applications (“Settings” > “Apps” > Swipe the
screen from right to left until “RUNNING” tab appears) and stop
3. What should I do in case I forgot the screen lock?
the unused applications (Tap the desired application, and then tap
You can set screen lock as pattern or password. If you forgot the “Stop”).
password, please consult your device provider or reset your device. > Check all installed applications and remove the unnecessary
In light that you often use X-431 PADII to diagnose vehicles and it may applications.
take you several minutes to do resetting, you are not recommended to If all steps mentioned above are finished and the system still works
define screen lock. slowly. Please try to close the system and reboot your X-431 PADII.
For detailed information on how to restore X-431 PADII to factory
settings, please refer to Item 4 “How to reset X-431 PADII tablet?” 6. Why some videos on the website can be not played?
described as below. It possibly results from:
111 The current browser does not support Flash playing;
4. How to reset X-431 PADII tablet?
222 Flash player does not support this video.
Do the followings to reset X-431 PADII: Try to use other browsers to watch it or install other Flash player.
111 Ensure X-431 PADII is in OFF mode;

48
LAUNCH X-431 PADII User's Manual

7. The data and time of X-431 PADII can not be set.


It is because Automatic date & time is set on your X-431 PADII. Tap
Settings > Date & time, deselect “Automatic date & time” and then set
the date and time manually.

49
LAUNCH X-431 PADII User's Manual

Warranty Customer Service


Any question during the operation, please call 86-755-89366558.
THIS WARRANTY IS EXPRESSLY LIMITED TO PERSONS
WHO PURCHASE LAUNCH PRODUCTS FOR PURPOSES OF If your unit requires repair service, return it to the manufacturer with
RESALE OR USE IN THE ORDINARY COURSE OF THE BUYER’S a copy of the sales receipt and a note describing the problem. If the
BUSINESS. unit is determined to be in warranty, it will be repaired or replaced at
no charge. If the unit is determined to be out of warranty, it will be
LAUNCH electronic product is warranted against defects in materials repaired for a nominal service charge plus return freight. Send the unit
and workmanship for one year from date of delivery to the user. pre-paid to:
This warranty does not cover any part that has been abused, altered, Attn: Customer Service Department
used for a purpose other than for which it was intended, or used in a
manner inconsistent with instructions regarding use. The exclusive LAUNCH TECH. CO., LTD.
remedy for any automotive meter found to be defective is repair or Launch Industrial Park,
replacement, and LAUNCH shall not be liable for any consequential or North of Wuhe Avenue,
incidental damages.
Banxuegang, Bantian,
Final determination of defects shall be made by LAUNCH in
Longgang, Shenzhen, Guangdong
accordance with procedures established by LAUNCH. No agent,
employee, or representative of LAUNCH has any authority to bind P.R.China, 518129
LAUNCH to any affirmation, representation, or warranty concerning Launch website: http://www.cnlaunch.com
LAUNCH automotive meters, except as stated herein. http://www.golo365.com
Disclaimer
The above warranty is in lieu of any other warranty, expressed or
implied, including any warranty of merchantability or fitness for a Statement:
particular purpose. LAUNCH reserves the rights to make any change to product designs
Purchase Order and specifications without notice. The actual object may differ a little
from the descriptions in the manual in physical appearance, color
Replaceable and optional parts can be ordered directly from your
and configuration. We have tried our best to make the descriptions
LAUNCH authorized tool supplier. Your order should include the
and illustrations in the manual as accurate as possible, and defects
following information:
are inevitable, if you have any question, please contact local dealer
Order quantity or after-sale service center of LAUNCH, LAUNCH does not bear any
Part number responsibility arising from misunderstandings.
Part name