Sunteți pe pagina 1din 112

Modify Cell Algorithm Switch Configuration (MOD

CELLALGOSWITCH)
Function

Use this command to modify the settings of cell-level algorithm switches.

Note

This is a high-risk MML command. Pay attention to the following precautions before running this
command:
 Before setting McpttSwitch on, check that no service uses QCI 65, 66, 69, or 70. If QCI 65,
66, 69, or 70 is used by a service, plan a different QCI for the service.
 A modification to the PucchAlgoSwitch parameter will result in automatic reset of the cell.
For a FDD cell, a modification to the DynSpectrumShareSwitch parameter will result in
automatic reset of the cell.
A modification to the RanShareModeSwitch parameter will result in automatic reset of the
cell.
For a FDD cell, a modification to the SuperCombCellSwitch in SfnAlgoSwitch parameter will
result in automatic reset of the cell.
For a TDD cell, a modification to the ComCoverUlCompSwitch in SfnUplinkCompSwitch
parameter will result in automatic reset of the cell.
 When SubframeAssignment is set to 0, the TTI Bundling function cannot be enabled.
Otherwise, the services will be interrupted.
 If FPIGTPUSwitch or DSCPRemarkSwitch of the ServiceDiffSwitch parameter in the
CELLSERVICEDIFFCFG MO is on, switches of the ServiceDiffSwitch parameter in the
CellAlgoSwitch MO must be off. If one switch of the ServiceDiffSwitch parameter in the
CellAlgoSwitch MO is on, switches of the ServiceDiffSwitch parameter in the
CELLSERVICEDIFFCFG MO must be off.
 If the OuterLoopPucchSwitch option of the UlPcAlgoSwitch parameter needs to be selected,
the InnerLoopPucchSwitch option of this parameter must be selected.
 TddAvoidUpPTSInterfSwitch: Selecting this option may lead to automatic cell reestablishment
when interference occurs or required signal quality recovers from deterioration due to
interference.

Parameters

ID Name Description

Meaning: Indicates the local ID of the cell. It uniquely identifies a cell


LocalCellId Local cell
within a BS.
ID
GUI Value Range: 0~255
Unit: None
Actual Value Range: 0~255
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification: N/A
Impact on Radio Network Performance: None
Applicable Mode: L

VolteRedirectSwit VoLTE Meaning: Controls whether VoLTE services support redirection.


ch Redirect If this parameter is set to ON, VoLTE services support redirection
Switch and QCI-1 UEs can be redirected. If this parameter is set to OFF,
redirection is not supported for QCI-1 UEs.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
ON, QCI-1 UEs can be redirected and call drops may be prevented
during temporary voice service interruption, ensuring user
experience. However, the number of intra-RAT intra-duplex-mode
redirections increases.
Applicable Mode: L

RachAlgoSwitch RACH Meaning: RACHAdjSwitch: Indicates whether to enable random


algorithm access channel (RACH) resource adjustment, which adaptively
switch adjusts the RACH resources in the cell based on the access type
and the number of access attempts. If this option is deselected,
RACH resource adjustment is disabled.
HoRaSwitch: Indicates whether the random access mode is applied
during handovers. If this option is selected, the eNodeB instructs
UEs to use the non-contention-based random access mode during
handovers. If this option is deselected, the eNodeB instructs UEs to
use the contention-based random access mode during handovers.
UnsyncRaSwitch: Indicates whether the random access mode is
applied when UEs are out of synchronization in the uplink. If this
option is selected, the eNodeB instructs UEs to use the non-
contention-based random access mode upon downlink data arrivals
in the case of out-of-synchronization. If this option is deselected, the
eNodeB instructs UEs to use the contention-based random access
mode upon downlink data arrivals in the case of out-of-
synchronization.
MaksIdxSwitch: Indicates whether to reuse dedicated preambles
between UEs. If this option is selected, the eNodeB enables reuse
of dedicated preambles among UEs based on the MaskIndex
parameter. If this option is deselected, the eNodeB allocates a
dedicated preamble to only one UE at a time.
BackOffSwitch: Indicates whether to enable backoff control. If this
option is selected, backoff control is enabled. If this option is
deselected, backoff control is disabled.
UeRaInforInqSwitch: Indicates whether the query of UE random
access information is enabled. If this option is selected, the query of
UE random access information is enabled, and the eNodeB sends
the UEInformationRequest message to the UE complying with 3GPP
Release 9 and later and requires the UE reporting random access
information. The eNodeB uses the reported random access
information for RACH resource adjustment. If this option is
deselected, the query of UE random access information is disabled.
The eNodeB uses the self-collected random access information for
RACH resource adjustment.
PRACHFalseAlarmDetSwitch: Indicates whether to enable PRACH
false alarm detection. If this option is selected and the
PrachFalseAlarmDetRadThd or RachThdBoostRatio parameter is
not set to 0, PRACH false alarm detection is enabled. If the eNodeB
considers the initial contention-based preamble sent by a UE as a
PRACH false alarm, the eNodeB does not send the UE a Random
Access Response message, nor records the preamble on the
performance counter L.RA.GrpA.Att or L.RA.GrpB.Att if the
preamble belongs to group A or B, respectively. If this option is
selected and the PrachFalseAlarmDetRadThd and
RachThdBoostRatio parameters are set to 0, PRACH false alarm
detection is disabled. If this option is deselected, PRACH false alarm
detection is disabled.
RachPwrAdjSwitch: Indicates whether to enable power adjustment
for the RACH. If both this option and UeRaInforInqSwitch are
selected, the eNodeB dynamically adjusts the parameters related to
power control for the RACH based on the number of random access
preambles, probability of successful random accesses, and target
probability of successful random accesses. If either this option or
UeRaInforInqSwitch is deselected, power adjustment for the RACH
is disabled.
ForbidAcByRadiusSwitch: Indicates whether the eNodeB controls
UE access based on the distance from UEs to the eNodeB or not. If
this option is selected, only UEs whose distance to the eNodeB is
less than the cell radius are allowed to access the cell. If this option
is deselected, the eNodeB does not forbid UE access based on the
distance.
PrachFreqAdjSwitch: Indicates whether to enable PRACH
frequency-domain position adaptation. If the PucchSwitch option of
the PucchAlgoSwitch parameter is selected, the
PrachFreqOffsetStrategy parameter is set to
AUTOMATIC(AUTOMATIC), and this option is selected, the PRACH
frequency-domain position is adaptively adjusted based on the
PUCCH resource usage.
PRACHFalseAlaDetRetxOptSwitch: Indicates whether to allow the
access from abnormal UEs that retransmit preambles at an interval
of 40 ms when PRACH false alarm detection is enabled. When this
option is selected, an eNodeB can identify preambles retransmitted
at an interval of 40 ms and allow the access from UEs transmitting
these preambles. When this option is deselected, an eNodeB cannot
identify preambles retransmitted at an interval of 40 ms.
GUI Value Range: RachAdjSwitch(RachAdjSwitch),
HoRaSwitch(HoRaSwitch), UnsyncRaSwitch(UnsyncRaSwitch),
MaksIdxSwitch(MaksIdxSwitch), BackOffSwitch(BackOffSwitch),
UeRaInforInqSwitch(UeRaInforInqSwitch),
PRACHFalseAlarmDetSwitch(PRACHFalseAlarmDetSwitch),
RachPwrAdjSwitch(RachPwrAdjSwitch),
ForbidAcByRadiusSwitch(ForbidAcByRadiusSwitch),
PrachFreqAdjSwitch(PrachFreqAdjSwitch),
PRACHFalseAlaDetRetxOptSwitch(PRACHFalseAlaDetRetxOptSwi
tch)
Unit: None
Actual Value Range: RachAdjSwitch, HoRaSwitch,
UnsyncRaSwitch, MaksIdxSwitch, BackOffSwitch,
UeRaInforInqSwitch, PRACHFalseAlarmDetSwitch,
RachPwrAdjSwitch, ForbidAcByRadiusSwitch, PrachFreqAdjSwitch,
PRACHFalseAlaDetRetxOptSwitch
MML Default Value: None
Recommended Value: RachAdjSwitch:Off, HoRaSwitch:On,
UnsyncRaSwitch:On, MaksIdxSwitch:Off, BackOffSwitch:Off,
UeRaInforInqSwitch:Off, PRACHFalseAlarmDetSwitch:Off,
RachPwrAdjSwitch:Off, ForbidAcByRadiusSwitch:Off,
PrachFreqAdjSwitch:Off, PRACHFalseAlaDetRetxOptSwitch:Off
Parameter Relationship:
-Others:
If PrachConfigIndexCfgInd in the RACHCfg MO is set to NOT_CFG
and RachAdjSwitch is selected, the RACH resources in the cell can
be adaptively adjusted based on the access type and the number of
access attempts.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: RachAdjSwitch: If this
option is selected, based on the number of UEs that have accessed
the cell, the algorithm increases the efficiency of utilizing dedicated
preambles while ensuring a low probability (less than or equal to
1%) that a UE is not allocated a dedicated preamble for random
access triggered by handover (case 3) or arrival of downlink data
(case 4). In addition, the algorithm increases the PRACH utilization
efficiency while ensuring a low probability (less than or equal to 1%)
that multiple UEs send the same preamble to initiate random access
procedures triggered by initial access (case 1), radio link failure
(case 2), or arrival of uplink data (case 5) at the same time. If this
option is deselected, RACH resources for contention-based and
non-contention-based random accesses are fixed and the benefits
of the algorithm are unavailable.
HoRaSwitch: If this option is selected, the eNodeB instructs UEs to
perform non-contention-based random access during handovers. As
a result, the handover delay is shorter than that in contention-based
random access. Deselecting this option leads to the opposite
effects.
UnsyncRaSwitch: If this option is selected, the eNodeB instructs
UEs to perform non-contention-based random access to change
from the out-of-synchronization state to the synchronized state. As a
result, the state transition delay is shorter than that in contention-
based random access. Deselecting this option leads to the opposite
effects.
MaksIdxSwitch: If this option is selected, the eNodeB enables reuse
of dedicated preambles among UEs at different times. The reuse
increases the dedicated preamble utilization efficiency but also
increases the random access delay. Deselecting this option leads to
the opposite effects.
BackOffSwitch: If this option is selected, UEs that experience
contention resolution failures retransmit preambles after a period of
time. This relieves RACH congestion but increases the random
access delay. Deselecting this option leads to the opposite effects.
PRACHFalseAlarmDetSwitch: Deselecting this option has no impact
on network performance. If this option is selected and the
PrachFalseAlarmDetRadThd and RachThdBoostRatio parameter
are set to 0, the network performance is not affected. If this option is
selected and the PrachFalseAlarmDetRadThd or
RachThdBoostRatio parameter is not set to 0, impacts on network
performance are determined based on settings of the
PrachFalseAlarmDetRadThd or RachThdBoostRatio parameter.
RachPwrAdjSwitch: If this option is selected, the eNodeB adjusts the
UE transmit power for random access based on UE access
information to meet the requirement of random access delay and
reduce interference on intra-frequency neighboring cells. If this
option is deselected, the eNodeB does not dynamically adjust the
values of parameters PreambInitRcvTargetPwr and
PwrRampingStep.
ForbidAcByRadiusSwitch: If this option is selected, the eNodeB
accurately forbids UEs whose distance to the eNodeB exceeds the
cell radius to access the cell, which may decrease the RACH access
success rate and RRC connection establishment success rate.
Deselecting this option has no impact on network performance.
PrachFreqAdjSwitch: If this option is selected, the PucchSwitch
option of the PucchAlgoSwitch parameter is selected, and the
PrachFreqOffsetStrategy parameter is set to
AUTOMATIC(AUTOMATIC), the PRACH frequency-domain position
is adaptively adjusted based on the PUCCH resource usage.
Selecting this option slightly increases the cell capacity when all of
the following conditions are met: (1) The number of UEs in the cell is
small; (2) All of the UEs perform full-buffer or burst services; (3) The
traffic requirement is large.
PRACHFalseAlaDetRetxOptSwitch: When this option is selected,
the probability of accepting access from UEs with real access
requirements increases. However, the probability of detecting
PRACH false alarms also increases and the RACH access success
rate decreases. When this option is deselected, an eNodeB regards
a preamble retransmitted at an interval of 40 ms as an initially
transmitted preamble and does not allow the access. As a result, the
probability of accepting UE access decreases, the probability of
detecting PRACH false alarms also decreases, and the RACH
access success rate increases. However, the probability of
accepting the access from some UEs with real access requirements
decreases.
Applicable Mode: L

SrsAlgoSwitch SoundingR Meaning: Indicates the switch used to enable or disable change in
S the cell-specific SRS subframe configuration (that is, the adjustment
algorithm on the setting of the SrsSubframeCfg parameter).
switch If the switch is on, the algorithm dynamically adjusts the SRS
subframe configuration based on the usage of cell resources.
If the switch is off, the algorithm uses the initial configuration and
does not perform dynamic switching.
GUI Value Range:
SrsSubframeRecfSwitch(SrsSubframeRecfSwitch)
Unit: None
Actual Value Range: SrsSubframeRecfSwitch
MML Default Value: None
Recommended Value: SrsSubframeRecfSwitch:On
Parameter Relationship:
-Configuration constraints:
If the SuperCombCellSwitch check box under the SfnAlgoSwitch
parameter in the CellAlgoSwitch MO is selected, the
SrsSubframeRecfSwitch check box under the SrsAlgoSwitch
parameter in the CellAlgoSwitch MO must not be selected.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If SrsSubframeRecfSwitch
is off, no SRS subframes can be configured for UEs initially
accessing the network, which results in specification test failures. It
is recommended that SrsSubframeRecfSwitch be on and never
turned off. In this case, the cell throughput is high when the cell load
is low. When the cell load is high, the eNodeB automatically adjusts
cell-specific SRS subframes to allow the cell to serve the maximum
number of UEs. However, the cell throughput decreases because of
the SRS subframe overhead.
Applicable Mode: L

PucchAlgoSwitch PUCCH Meaning: PucchSwitch: Indicates whether to enable the PUCCH


algorithm resource adjustment algorithm.
switch If this option is selected, PUCCH resource adjustment is initiated
when the PUCCH resources are insufficient or excessive. If this
option is deselected, PUCCH resource adjustment is disabled.
PucchFlexCfgSwitch: Indicates whether to enable PUCCH flexible
configuration. This function does not take effect if an LBBPc is used
or the cell bandwidth is 1.4 or 3 MHz. When PUCCH flexible
configuration is enabled, frequency-domain uplink ICIC and uplink
frequency hopping scheduling cannot be used. If this option is
selected, an equal number of RBs (specified by the
PucchExtendedRBNum parameter) are separately added to both
ends of the uplink band allocated for the PUCCH. The total number
of extension PUCCH RBs equals the PucchExtendedRBNum
parameter value multiplied by 2, and the extension RBs can be used
for PUSCH scheduling. This option applies only to LTE FDD.
Dl2CCAckResShareSw: Indicates whether to enable PUCCH ACK
channel resource sharing for downlink 2CC CA. The eNodeB divides
the ACK channel resources on a PCC for downlink 2CC CA into four
groups. If this option is deselected, CA UEs scheduled on each SCC
associated with this PCC are allowed to use the ACK channel
resources in only one group. If this option is selected, CA UEs
scheduled on each SCC associated with this PCC can use the ACK
channel resources in any group.
SCCAckResourceCfgSW: Indicates whether to enable SCC ACK
resource configuration. If this option is selected, the eNodeB
controls the maximum number of RBs that can be used by PUCCH
format 3 and the maximum number of code channels that can be
used by SCC ACKs in 2CC CA scenarios according to the settings
of the Format3RBNum and Max2CCAckChNum parameters in the
PUCCHCfg MO, respectively. If this option is deselected, the
eNodeB controls the maximum number of RBs that can be used by
PUCCH format 3 and the maximum number of code channels that
can be used by SCC ACKs in 2CC CA scenarios based on related
algorithms.
GUI Value Range: PucchSwitch(PucchSwitch),
PucchFlexCfgSwitch(PucchFlexCfgSwitch),
Dl2CCAckResShareSw(Dl2CCAckResShareSw),
SCCAckResourceCfgSw(SCCAckResourceCfgSw)
Unit: None
Actual Value Range: PucchSwitch, PucchFlexCfgSwitch,
Dl2CCAckResShareSw, SCCAckResourceCfgSw
MML Default Value: None
Recommended Value: PucchSwitch:
In ultra-high-speed scenarios, the recommended value is Off.
In other scenarios, the recommended value is On.
PucchFlexCfgSwitch:
If PUCCHs are interfered, the recommended value is On.
If PUCCHs are not interfered, the recommended value is Off.
Dl2CCAckResShareSw:On
SCCAckResourceCfgSw:
In scenarios where CA works properly and the number of PUCCH
RBs needs to be limited, the recommended value is On. In other
scenarios, the recommended value is Off.
Parameter Relationship:
-Configuration constraints:
If either PucchSwitch or PucchFlexCfgSwitch of PucchAlgoSwitch in
the CellAlgoSwitch MO is selected, SuperCombCellSwitch of
SfnAlgoSwitch in the CellAlgoSwitch MO must be deselected.
Service Interrupted After Modification: Yes
Impact on Radio Network Performance: PucchSwitch: If this option
is selected, the PUCCH resources increase or decrease adaptively
based on the load on the PUCCH. This achieves better utilization of
PUCCH resources and reduces uplink signaling overhead. When
the PUCCH resources decrease, however, CQI resources may need
to be reconfigured for a few UEs. The reconfiguration consumes
certain downlink resources. If this option is deselected, uplink
signaling overhead increases.
PucchFlexCfgSwitch: If this option is selected and the PUCCH
experiences interference, interference to the PUCCH can be
reduced or even avoided, which improves the PUCCH demodulation
performance and also increases the access performance and
downlink throughput. However, the PUSCH resources become
nonconsecutive, which decreases the uplink throughput. Therefore,
uplink peak rate tests are not supported in this scenario. If this
option is deselected and two edges of the uplink frequency band
experience severe interference, the interference cannot be avoided
and the PUCCH demodulation performance decreases.
Dl2CCAckResShareSw: If the number of SCCs is less than 4,
selecting this option increases the scheduling capabilities of CA UEs
treating the local cell as their PCell, accelerates the expansion of
PUCCH resources, but decreases uplink throughput; deselecting
this option achieves the opposite effects.
SCCAckResourceCfgSW: If this option is selected and the
Format3RbNum and Max2CCAckChNum parameters are set to
large values, there is a high probability that the number of CA UEs
scheduled in a single TTI is large. As a result, the number of RBs
required for the PUCCH increases and the number of RBs required
for the PUSCH decreases, causing a possible decrease in uplink
throughput. If this option is selected and the Format3RbNum and
Max2CCAckChNum parameters are set to small values, the number
of RBs required for the PUCCH decreases and the number of RBs
required for the PUSCH increases, causing a possible increase in
uplink throughput. If this option is deselected, there is no impact on
the number of scheduled CA UEs and uplink throughput.
Applicable Mode: L

AqmAlgoSwitch AQM Meaning: Indicates the switch that is used to enable and disable the
algorithm Active Queue Management (AQM) algorithm. If this switch is set to
switch ON, the AQM function is enabled to prevent or control congestion.
The length of the PDCP packet queue is maintained at a relatively
small value to help achieve an appropriate trade-off between
throughput and time latency. If this switch is set to OFF, the AQM
function is disabled.
GUI Value Range: AqmAlgoSwitch
Unit: None
Actual Value Range: AqmAlgoSwitch
MML Default Value: None
Recommended Value: AqmAlgoSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: When this switch is turned
on, the delay of interactive services decreases and the time required
for downloading large-sized files increases slightly. When this switch
is turned off, there is no impact on radio network performance.
Applicable Mode: L

CqiAdjAlgoSwitch CQI Adjust Meaning: CqiAdjAlgoSwitch: Indicates whether to allow the eNodeB
Algorithm to adjust the UE-reported CQI based on the initial block error rate
Switch (IBLER). If this option is selected, the CQI adjustment algorithm is
enabled. In this case, the eNodeB adjusts the UE-reported CQI
based on the IBLER. If this option is deselected, the CQI adjustment
algorithm is disabled. In this case, the eNodeB does not adjust the
UE-reported CQI based on the IBLER.
StepVarySwitch: Indicates whether to enable the variable-step-
based adjustment algorithm. If this option is selected, the variable-
step-based adjustment algorithm is enabled to accelerate the
convergence of IBLER. In this case, rapid adjustment at large steps
is applied if there is a relatively large difference between the
measured IBLER and target IBLER; fine-tuning at small steps is
applied if the measured IBLER approaches the target IBLER. If this
option is deselected, the adjustment is performed at a fixed step.
DlVarIBLERtargetSwitch: Indicates whether to enable downlink
target IBLER adaptation. If this option is selected, the downlink
target IBLER is adjusted based on the size of transport blocks (TBs)
to improve the spectral efficiency. If this option is deselected, the
target IBLER is determined based on the setting of
DlEnVarIblerTargetSwitch.
TddBundlingCqiAdjOptSwitch: Indicates whether to enable
optimized CQI adjustment algorithm in ACK bundling mode. If this
option is selected, the optimized CQI adjustment algorithm is
enabled. If this option is deselected, the optimized CQI adjustment
algorithm is disabled.
TddMultiplexingCqiAdjOptSwitch: Indicates whether to enable the
optimized CQI adjustment algorithm in ACK multiplexing mode. If
this option is selected, the optimized CQI adjustment algorithm is
enabled. If this option is deselected, the optimized CQI adjustment
algorithm is disabled.
AdaptiveStepVarySwitch: Indicates whether to enable adaptive step
change in CQI adjustment. If this option is selected, significant
changes in the signal quality can be detected, and the CQI
adjustment is performed at a large step, accelerating the IBLER
convergence. If this option is deselected, the CQI adjustment is
performed at a fixed step.
DlCqiAdjDeltaOptSwitch: Indicates whether to enable optimization
on downlink CQI adjustment calculation. If this option is deselected,
the CQI adjustment is calculated based on the following formula:
CQI adjustment = (Number of ACKs for initial transmissions x CQI
adjustment per ACK + Number of NACKs for initial transmissions x
CQI adjustment per NACK)/(Number of NACKs for initial
transmissions + Number of ACKs for initial transmissions). If this
option is selected, the CQI adjustment is calculated based on the
following formula: CQI adjustment = Number of ACKs for initial
transmissions x CQI adjustment per ACK + Number of NACKs for
initial transmissions x CQI adjustment per NACK).
DlEnVarIblerTargetSwitch: Indicates whether to enable enhanced
downlink target IBLER adaption. If this option is selected, the
downlink target IBLER is adaptively adjusted based on CQI
fluctuation and TB size. If this option is deselected, the downlink
target IBLER policy is controlled by DlVarIBLERtargetSwitch.
DlRetxTbsIndexAdjOptSwitch: Indicates whether to enable transport
block size (TBS) index adjustment optimization in retransmissions. If
this option is selected, TBS index adjustment optimization in
retransmissions is enabled. The TBS index is lowered for the
scheduling of the last two retransmissions, and the TBS index is
determined based on the CQI adjustment for the scheduling of other
retransmissions. If this option is deselected, TBS index adjustment
optimization in retransmissions is disabled. The TBS index is
determined based on the CQI adjustment for the scheduling of all
retransmissions.
CfiConvertOptSwitch: Indicates whether to enable CFI calculation
optimization. If this option is selected, new CFI calculation tables for
normal and special subframes are used to ensure more accurate
MCS selection in normal and special subframes and facilitate IBLER
convergence to the target value. If this option is deselected, the
original CFI calculation tables for normal and special subframes are
used. This option applies only to LTE TDD.
BundlingOptThdSwitch: Indicates whether to adjust the MCS index
threshold for enabling the optimized CQI adjustment algorithm in
TDD bundling mode. If this option is selected, the lower MCS index
threshold for enabling the optimized CQI adjustment algorithm in
TDD bundling mode is changed from MCS index 6 to MCS index 0.
If this option is deselected, the lower MCS index threshold for
enabling the optimized CQI adjustment algorithm in TDD bundling
mode is MCS index 6. This option applies only to LTE TDD.
DlSpsMcsIncreaseSwitch: Indicates whether to enable MCS index
increase for semi-persistent scheduling (SPS). If this option is
selected, MCS index increase is enabled for SPS. If this option is
deselected, MCS index increase is disabled for SPS. Turning on this
switch can reduce the number of RBs for SPS and improve cell
performance when the RB resource is limited but may decrease the
VoLTE MOS. Turning off this switch may increase the number of
RBs for SPS but increase the VoLTE MOS.
CqiAdjTimeEffSwitch: Indicates whether to enable validity evaluation
and adjustment for CQI adjustment values, and also controls
whether to trigger large-step-based CQI adjustment in the scenario
where a long time has elapsed before a UE begins to perform
services together with the AdaptiveStepVarySwitch option setting. If
this option is selected, the eNodeB evaluates the validity of all CQI
adjustment values in a unified manner and adjusts these adjustment
values based on the evaluation results. If this option and the
AdaptiveStepVarySwitch option are selected, large-step-based CQI
adjustment is triggered in the scenario where a long time has
elapsed before a UE begins to perform services. If this option is
deselected, the eNodeB does not evaluate the validity of CQI
adjustment values or adjust these values in a unified manner, and
large-step-based CQI adjustment is not triggered in the scenario
where a long time has elapsed before a UE begins to perform
services.
RptCqiFltInitSwitch: Indicates whether to adjust the initial filtered
value of the reported CQI. If this option is selected, the initial filtered
value of the reported CQI is determined based on the CQI value
reported by the UE, and the filtering coefficient for the reported CQI
in the first several reporting periods is adjusted. If this option is
deselected, the initial filtered value of CQIs reported by all UEs is
fixed to 4.
UeSigInitCqiModSwitch: Indicates the time when the reported initial
CQI takes effect. If this option is selected, the reported initial CQI
takes effect when the ACK to MSG4 HARQ retransmission is
received or when MSG5 is received. If this option is deselected, the
reported CQI immediately takes effect. This option applies only to
LTE TDD.
CqiFastCompstSwitch: Indicates whether the eNodeB performs fast
CQI compensation for the following UEs: UEs handed over to cells
whose values of PCI modulo 3 conflict with source cells' values of
PCI modulo 3, beamforming UEs in 8T8R cells, and UEs reporting
aperiodic CQIs during network access under a high CAPS condition.
If this option is selected, the eNodeB identifies these UEs and
quickly compensates for the CQIs of these UEs. If this option is
deselected, the eNodeB does not identify these UEs for CQI
compensation. This option applies only to LTE TDD.
GUI Value Range: CqiAdjAlgoSwitch(CqiAdjAlgoSwitch),
StepVarySwitch(StepVarySwitch),
DlVarIBLERtargetSwitch(DlVarIBLERtargetSwitch),
TddBundlingCqiAdjOptSwitch(TddBundlingCqiAdjOptSwitch),
TddMultiplexingCqiAdjOptSwitch(TddMultiplexingCqiAdjOptSwitch),
AdaptiveStepVarySwitch(AdaptiveStepVarySwitch),
DlCqiAdjDeltaOptSwitch(DlCqiAdjDeltaOptSwitch),
DlEnVarIblerTargetSwitch(DlEnVarIblerTargetSwitch),
DlRetxTbsIndexAdjOptSwitch(DlRetxTbsIndexAdjOptSwitch),
CfiConvertOptSwitch(CfiConvertOptSwitch),
BundlingOptThdSwitch(BundlingOptThdSwitch),
DlSpsMcsIncreaseSwitch(DlSpsMcsIncreaseSwitch),
CqiAdjTimeEffSwitch(CqiAdjTimeEffSwitch),
RptCqiFltInitSwitch(RptCqiFltInitSwitch),
UeSigInitCqiModSwitch(UeSigInitCqiModSwitch),
CqiFastCompstSwitch(CqiFastCompstSwitch)
Unit: None
Actual Value Range: CqiAdjAlgoSwitch, StepVarySwitch,
DlVarIBLERtargetSwitch, TddBundlingCqiAdjOptSwitch,
TddMultiplexingCqiAdjOptSwitch, AdaptiveStepVarySwitch,
DlCqiAdjDeltaOptSwitch, DlEnVarIblerTargetSwitch,
DlRetxTbsIndexAdjOptSwitch, CfiConvertOptSwitch,
BundlingOptThdSwitch, DlSpsMcsIncreaseSwitch,
CqiAdjTimeEffSwitch, RptCqiFltInitSwitch, UeSigInitCqiModSwitch,
CqiFastCompstSwitch
MML Default Value: None
Recommended Value: In LTE FDD: CqiAdjAlgoSwitch:On,
StepVarySwitch:Off, DlVarIBLERtargetSwitch:On,
TddBundlingCqiAdjOptSwitch:Off,
TddMultiplexingCqiAdjOptSwitch:Off, AdaptiveStepVarySwitch:Off,
DlCqiAdjDeltaOptSwitch:Off, DlEnVarIblerTargetSwitch:Off,
DlRetxTbsIndexAdjOptSwitch:Off, DlSpsMcsIncreaseSwitch:Off,
RptCqiFltInitSwitch:Off.
In LTE TDD: CqiAdjAlgoSwitch:On, StepVarySwitch:Off,
DlVarIBLERtargetSwitch:Off, TddBundlingCqiAdjOptSwitch:Off,
TddMultiplexingCqiAdjOptSwitch:Off, AdaptiveStepVarySwitch:Off,
DlEnVarIblerTargetSwitch:Off, DlRetxTbsIndexAdjOptSwitch:Off,
CfiConvertOptSwitch:Off, BundlingOptThdSwitch:Off,
DlSpsMcsIncreaseSwitch:Off, CqiAdjTimeEffSwitch:Off,
RptCqiFltInitSwitch:Off, UeSigInitCqiModSwitch:Off.
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: CqiAdjAlgoSwitch: If this
option is selected, the UE reports CQIs more accurately, increasing
the downlink rate. If this option is deselected, the UE may report
CQIs inaccurately, decreasing the downlink rate.
StepVarySwitch: If this option is selected, the IBLER convergence
rate can be adjusted based on site scenarios, increasing the
downlink rate in some scenarios. If this option is deselected, the
IBLER convergence rate cannot be adjusted, decreasing the
downlink rate in some scenarios.
DlVarIBLERtargetSwitch: If this option is selected, the target IBLER
can be adjusted based on site scenarios, increasing the downlink
rate. If this option is deselected, the target IBLER cannot be
adjusted, decreasing the downlink rate in some scenarios.
TddBundlingCqiAdjOptSwitch: If this option is selected, for UEs
using the ACK bundling mode, the eNodeB uses the optimized CQI
adjustment algorithm and chooses a more proper MCS, increasing
downlink throughput of each UE and cell average downlink
throughput. If this option is deselected, for UEs using the ACK
bundling mode, the eNodeB uses the non-optimized CQI adjustment
algorithm, which may result in a smaller MCS index, lower downlink
throughput of each UE, and lower cell average downlink throughput.
TddMultiplexingCqiAdjOptSwitch: If this option is selected, for UEs
using the ACK multiplexing mode, the eNodeB uses the optimized
CQI adjustment mechanism and chooses a more proper MCS,
increasing downlink throughput of each UE and downlink cell
average throughput. If this option is deselected, for UEs using the
ACK multiplexing mode, the eNodeB uses the non-optimized CQI
mechanism, which may result in an incorrect MCS index for special
subframes and decrease downlink throughput of each UE and cell
average downlink throughput.
AdaptiveStepVarySwitch: If this option is selected, the CQI
adjustment is performed at a large step in case of significant signal
quality changes, accelerating the IBLER convergence and therefore
increasing the downlink throughput. If this option is deselected, the
CQI adjustment is performed at a fixed step, which has no impact on
network performance.
DlCqiAdjDeltaOptSwitch: If this option is selected, the IBLER
convergence performance improves and downlink throughput
increases. However, the RBLER and service drop rate may also
deteriorate. Deselecting this option has no impact on network
performance.
DlEnVarIblerTargetSwitch: If this option is selected, downlink
throughput increases when channel quality fluctuates greatly or
slightly or the proportion of small-packet services is high. However,
the RBLER may increase. Deselecting this option has no impact on
network performance.
DlRetxTbsIndexAdjOptSwitch: If this option is selected, both the
downlink RBLER and the service drop rate decrease, but downlink
throughput may also decrease slightly. Deselecting this option has
no impact on network performance.
CfiConvertOptSwitch: If this option is selected, the CFI calculation
tables for normal and special subframes are optimized. In this case,
the MCS index is increased to improve downlink throughput.
However, the service drop rate may slightly increase.
BundlingOptThdSwitch: If this option is selected, the MCS index
threshold for enabling the optimized CQI adjustment algorithm in
TDD bundling mode decreases. In this case, when the downlink
target IBLER adaption algorithm is disabled, the optimized CQI
adjustment algorithm in TDD bundling mode helps increase the
throughput of CEUs with an MCS index ranging from 0 to 6.
However, the IBLER, MCS index, and service drop rate may also
increase.
DlSpsMcsIncreaseSwitch: Selecting this option can reduce the
number of RBs for SPS and increase the throughput of data
services but may decrease the VoLTE MOS. Deselecting this option
has no impact on network performance.
CqiAdjTimeEffSwitch: If this option is selected, the eNodeB
evaluates the validity of CQI adjustment values and adjusts the
values if they are inappropriate. This algorithm prevents the network
throughput and spectral efficiency from decreasing due to poor CQI
adjustment value validity. However, if the radio environment of a UE
remains unchanged for a long period, the eNodeB does not need to
update the CQI adjustment value to ensure accurate MCS index
selection. In this case, adjusting CQI adjustment values may bring
negative gains. According to theoretical analysis and network test
results, this scenario rarely occurs and even if it occurs, the negative
gain is small. Deselecting this option has no impact on network
performance.
RptCqiFltInitSwitch: If this option is selected, the throughput and
spectral efficiency increase for the UEs whose MCS index is low due
to the small initial filtered value. If this option is deselected, network
performance is not affected.
UeSigInitCqiModSwitch: If this option is selected, the CQI value
takes effect when the ACK to MSG4 HARQ retransmission is
received or when MSG5 is received. This prevents the eNodeB from
detecting abnormal CQI values and the KPIs are not affected. If this
option is deselected, the reported CQI immediately takes effect. In
this case, the eNodeB may detect abnormal CQI values during
MSG4 retransmissions and the KPIs are affected.
CQIFastCompensationSwitch: If this option is selected, an eNodeB
identifies handover UEs which have PCI modulo 3 conflicts, BF UEs
in 8T8R antenna configuration, and new UEs that perform aperiodic
CQI reporting when CAPS is high and performs CQI fast
compensation for these UEs. This can increase the MCS of these
UEs and the throughput. If this option is deselected, an eNodeB
cannot identify these UEs. The MCS index selection of these UEs
needs to be adjusted slowly by outer loop power control, which
consumes more resources. Also it is difficult to adjust the MCS index
selection when downlink scheduling packets of the UE are
insufficient. In this case, the spectral efficiency cannot be
maximized.
Applicable Mode: L

DynAdjVoltSwitch Dynamic Meaning: Indicates the switch used to enable or disable dynamic
adjust power adjustment. If this switch is on, the power amplifier (PA)
voltage working voltage is adjusted based on the load of the eNodeB, which
algorithm reduces power consumption of the PA and improves energy
switch efficiency of the eNodeB. Dynamic power adjustment applies only to
FDD cells with a bandwidth no less than 5 MHz.
GUI Value Range: DynAdjVoltSwitch(DynAdjVoltSwitch)
Unit: None
Actual Value Range: DynAdjVoltSwitch
MML Default Value: None
Recommended Value: Dynamic Adjust Voltage Switch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

RacAlgoSwitch RAC Meaning: Indicates whether to enable the admission and load
algorithm control algorithms.
switch DlSwitch: Indicates whether to enable the algorithm of downlink
admission control based on the satisfaction rate. If this option is
selected, the algorithm is enabled. If this option is deselected, the
algorithm is disabled. Among services with different QCIs, those with
a QCI of 1 use the QoS satisfaction assessment method that is
dedicated to VoLTE services. If a service with the QCI of 1 is not a
VoLTE service, the satisfaction rate calculated using this method is
lower than the actual value, which affects the admission of GBR
services. Therefore, if not all the services with the QCI of 1 are
VoLTE services, it is recommended that this option be deselected.
UlSwitch: Indicates whether to enable the algorithm of uplink
admission control based on the satisfaction rate. If this option is
selected, the algorithm is enabled. If this option is deselected, the
algorithm is disabled. Among services with different QCIs, those with
a QCI of 1 use the QoS satisfaction assessment method that is
dedicated to VoLTE services. If a service with the QCI of 1 is not a
VoLTE service, the satisfaction rate calculated using this method is
lower than the actual value, which affects the admission of GBR
services. Therefore, if not all the services with the QCI of 1 are
VoLTE services, it is recommended that this option be deselected.
DlLdcSwitch: Indicates whether to implement load control in the
downlink of a cell. If this option is selected, the eNodeB checks for
congestion in the downlink of the cell. If the downlink is congested,
load control is performed. If this option is deselected, the eNodeB
does not check for congestion in the downlink of the cell and the
congestion cannot be relieved. Among services with different QCIs,
those with a QCI of 1 use the QoS satisfaction assessment method
that is dedicated to VoLTE services. If a service with the QCI of 1 is
not a VoLTE service, the satisfaction rate calculated using this
method is lower than the actual value, which affects the cell load
control. Therefore, if not all the services with the QCI of 1 are VoLTE
services, it is recommended that this option be deselected.
UlLdcSwitch: Indicates whether to implement load control in the
uplink of a cell. If this option is selected, the eNodeB checks for
congestion in the uplink of the cell. If the uplink is congested, load
control is performed. If this option is deselected, the eNodeB does
not check for congestion in the uplink of the cell and the congestion
cannot be relieved. Among services with different QCIs, those with a
QCI of 1 use the QoS satisfaction assessment method that is
dedicated to VoLTE services. If a service with the QCI of 1 is not a
VoLTE service, the satisfaction rate calculated using this method is
lower than the actual value, which affects the cell load control.
Therefore, if not all the services with the QCI of 1 are VoLTE
services, it is recommended that this option be deselected.
PreemptionSwitch: Indicates whether to enable the preemption
algorithm. If this option is selected, preemption can be used when
the admission of high-priority services fails. If this option is
deselected, only emergency calls can be admitted to the system
when resources are insufficient.
PttAcSwitch: Indicates whether to enable RB-usage-based
admission control for PTT services. If this option is selected, RB-
usage-based admission control for PTT services is enabled. If this
option is deselected, RB-usage-based admission control for PTT
services is disabled.
VoltePrefAdmissionSwitch: Indicates whether to preferentially admit
VoLTE services. This option setting takes effect only if the
EutranVoipSupportSwitch parameter is set to ON(On). If this option
is selected, the eNodeB preferentially admits VoLTE services. If this
option is deselected, the eNodeB does not.
VoltePreemptionSwitch: Indicates whether to preferentially admit
VoLTE services by preempting other services. This option takes
effect only when VoltePrefAdmissionSwitch is selected. If this option
is selected, preemption is enabled. If this option is deselected,
preemption is disabled.
GUI Value Range: DlSwitch(dlCacSwitch), UlSwitch(ulCacSwitch),
DlLdcSwitch(dlLdcSwitch), UlLdcSwitch(ulLdcSwitch),
PreemptionSwitch(PreemptionSwitch), PttAcSwitch(PttAcSwitch),
VoltePrefAdmissionSwitch(VoltePrefAdmissionSwitch),
VoltePreemptionSwitch(VoltePreemptionSwitch)
Unit: None
Actual Value Range: DlSwitch, UlSwitch, DlLdcSwitch, UlLdcSwitch,
PreemptionSwitch, PttAcSwitch, VoltePrefAdmissionSwitch,
VoltePreemptionSwitch
MML Default Value: None
Recommended Value: DlSwitch:Off, UlSwitch:Off, DlLdcSwitch:Off,
UlLdcSwitch:Off, PreemptionSwitch:Off, PttAcSwitch:Off,
VoltePrefAdmissionSwitch:Off, VoltePreemptionSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: DlSwitch: If this option is
selected, GBR services are admitted based on the downlink load on
the air interface. This decreases the access success rate of GBR
services but guarantees the downlink satisfaction rate of admitted
GBR services. If this option is deselected, GBR services are not
admitted based on the downlink load on the air interface. This
guarantees the access success rate of GBR services but decreases
the downlink satisfaction rate of admitted GBR services.
UlSwitch: If this option is selected, GBR services are admitted based
on the uplink load on the air interface. This decreases the access
success rate of GBR services but guarantees the uplink satisfaction
rate of admitted GBR services. If this option is deselected, GBR
services are not admitted based on the uplink load on the air
interface. This guarantees the access success rate of GBR services
but decreases the uplink satisfaction rate of admitted GBR services.
DlLdcSwitch: If this option is selected, low-priority GBR services will
be released when downlink congestion occurs on the air interface.
This improves the downlink satisfaction rate of high-priority GBR
services but increases the service drop rate of low-priority GBR
services. If this option is deselected, low-priority GBR services will
not be released when downlink congestion occurs on the air
interface. This does not increase the service drop rate of low-priority
GBR services. However, the downlink satisfaction rate of high-
priority GBR services does not improve, either.
UlLdcSwitch: If this option is selected, low-priority GBR services will
be released when uplink congestion occurs on the air interface. This
improves the uplink satisfaction rate of high-priority GBR services
but increases the service drop rate of low-priority GBR services. If
this option is deselected, low-priority GBR services will not be
released when uplink congestion occurs on the air interface. This
does not increase the service drop rate of low-priority GBR services.
However, the uplink satisfaction rate of high-priority GBR services
does not improve, either.
PreemptionSwitch: If this option is selected, high-priority GBR
services preempt resources from admitted low-priority GBR services
when they fail to be admitted. This increases the access success
rate of high-priority GBR services as well as the service drop rate of
low-priority GBR services. If this option is deselected, high-priority
GBR services do not preempt resources from admitted low-priority
GBR services when they fail to be admitted. This does not increase
the access success rate of high-priority GBR services. However, the
service drop rate of low-priority GBR services does not increase,
either.
PttAcSwitch: If this option is selected, high-priority PTT services can
use only the RBs within the operator-specified scope, rather than all
RBs without limitation. If this option is deselected, PTT services can
preempt resources without limitations because of its high priorities.
VoltePrefAdmissionSwitch: If this option is selected, the eNodeB
preferentially admits VoLTE UEs while rejecting data service UEs
when the cell is congested, provided that the total number of UEs
does not exceed the maximum permissible number. If this option is
deselected, the eNodeB does not use this method, and VoLTE UEs
and data service UEs have the same chance of accessing the cell.
VoltePreemptionSwitch: If this option is selected, the eNodeB
preferentially admits VoLTE UEs by using the resources allocated to
data service UEs, provided that the total number of UEs does not
exceed the maximum permissible number. If this option is
deselected, the eNodeB does not use this method.
Applicable Mode: L

MlbAlgoSwitch Load Meaning: Indicates whether to enable mobility load balancing (MLB)
balancing algorithms. This parameter provides the following options:
algorithm InterFreqMlbSwitch, InterFreqIdleMlbSwitch,
switch InterFreqBlindMlbSwitch, UtranMlbSwitch, UtranIdleMlbSwitch,
GeranMlbSwitch, MlbLoadInfoSwitch, and VoIPOffloadSwitch. If one
option is selected, the corresponding algorithm is enabled to
balance the loads between the serving cell and neighboring cells of
the specified category.
InterFreqMlbSwitch: Indicates whether to enable inter-frequency
MLB.
UtranMlbSwitch: Indicates whether to enable MLB to UTRAN.
GeranMlbSwitch: Indicates whether to enable MLB to GERAN.
UtranIdleMlbSwitch: Indicates whether to enable "MLB to UTRAN by
transferring RRC_REL UEs."
MlbLoadInfoSwitch: Indicates whether the load of an inter-RAT cell
is considered when MLB is performed between an E-UTRAN cell
and an inter-RAT cell. This inter-RAT cell must be a UTRAN cell in
the current version. If both the MlbLoadInfoSwitch and
UtranMlbSwitch options are selected, a UTRAN cell whose load
status has been obtained and is normal or medium can be a
candidate cell for MLB to UTRAN. If both the MlbLoadInfoSwitch
and UtranIdleMlbSwitch options are selected, a UTRAN cell whose
load status has been obtained and is normal can be a candidate cell
for MLB to UTRAN.
InterFreqBlindMlbSwitch: Indicates whether to enable inter-
frequency MLB without load information exchange.
InterFreqIdleMlbSwitch: Indicates whether to enable inter-frequency
MLB for UEs in idle mode. If this option is selected, this type of MLB
takes effect only if at least one inter-frequency MLB mode is
selected for RRC_REL UEs.
VoIPOffloadSwitch: Indicates whether to enable the VoIP offload
function. If this option is selected, satisfaction rate assessment is
performed on VoIP services. If the satisfaction rate of VoIP services
is lower than the preset threshold, inter-frequency or inter-RAT
offload of VoIP services is triggered.
GUI Value Range: InterFreqMlbSwitch(InterFreqMlbSwitch),
UtranMlbSwitch(UtranMlbSwitch),
GeranMlbSwitch(GeranMlbSwitch),
UtranIdleMlbSwitch(UtranIdleMlbSwitch),
MlbLoadInfoSwitch(MlbLoadInfoSwitch),
InterFreqBlindMlbSwitch(InterFreqBlindMlbSwitch),
InterFreqIdleMlbSwitch(InterFreqIdleMlbSwitch),
VoIPOffloadSwitch(VoIPOffloadSwitch)
Unit: None
Actual Value Range: InterFreqMlbSwitch, UtranMlbSwitch,
GeranMlbSwitch, UtranIdleMlbSwitch, MlbLoadInfoSwitch,
InterFreqBlindMlbSwitch, InterFreqIdleMlbSwitch,
VoIPOffloadSwitch
MML Default Value: None
Recommended Value: It is recommended that the
InterFreqMlbSwitch and InterFreqIdleMlbSwitch options be
deselected if the cell load is light in an early stage of network
deployment (that is, the average cell load is lower than 50%) and
there is no obvious imbalance in the cell loads (that is, the load
difference between cells is lower than the related threshold).
It is recommended that the InterFreqMlbSwitch and
InterFreqIdleMlbSwitch options be selected if the cell load is heavy
(that is, the average load in the cell exceeds the inter-frequency
MLB threshold) and there is an imbalance in the load between cells
(that is, the load difference between cells exceeds the related
threshold).
It is recommended that the UtranMlbSwitch, UtranIdleMlbSwitch,
MlbLoadInfoSwitch, and GeranMlbSwitchall options be deselected if
the cell load is light in an early stage of network deployment (that is,
the average cell load is lower than 70%).
It is recommended that the UtranMlbSwitch, UtranIdleMlbSwitch,
MlbLoadInfoSwitch, and GeranMlbSwitch options all be selected if
the cell load is heavy (for example, the average load in the cell
exceeds the InterRatMlbThd parameter value).
If the EPC is capable of obtaining the load status of inter-RAT
neighboring cells, it is recommended that the MlbLoadInfoSwitch
option be selected.
If the X2 interface does not support load information exchange, it is
recommended that the InterFreqBlindMlbSwitch option be selected.
Assume that all the frequencies have the same cell-reselection
priority and UEs support all frequencies in a multi-frequency
network. If the UEs are required to be distributed among the
frequencies based on the preset proportions, it is recommended that
the InterFreqIdleMlbSwitch option be selected.
It is recommended that the VoIPOffloadSwitch option be selected in
a multi-frequency or multi-RAT network where there is a low-
bandwidth carrier carrying services of a large number of VoLTE UEs
in the LTE network and the carrier bears a large number of VoLTE
UEs; otherwise, the VoIPOffloadSwitch option is deselected.
Parameter Relationship:
-Configuration constraints:
In a CellAlgoSwitch MO, the InterFreqIdleMlbSwitch and
UtranIdleMlbSwitch under the MlbAlgoSwitch cannot be turned on
simultaneously.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If the InterFreqMlbSwitch
option is deselected, inter-frequency MLB is disabled. Then, when
the load in the local cell is heavy and the inter-frequency
neighboring cell is capable of handling additional traffic, traffic is not
offloaded from the local cell to the neighboring cell. Therefore, the
probability of overload is high, and the access success rate and the
total throughput are low. If this option is selected, inter-frequency
MLB is enabled. Then, when the load in the local cell is heavy and
an inter-frequency neighboring cell is capable of handling additional
traffic, traffic is offloaded from the local cell to the neighboring cell.
Therefore, the probability of overload in the system is low, and the
access success rate and the total throughput are high.
If one of the UtranMlbSwitch, UtranIdleMlbSwitch, and
GeranMlbSwitch options is selected, inter-RAT MLB is enabled.
Then, when the load in a cell is heavy and there is an imbalance in
the load between inter-RAT neighboring cells, the probability of
overload in the LTE network is low, and the access success rate and
the total throughput are high. If these options are all deselected,
inter-RAT MLB is disabled. Then, the inter-RAT load imbalances
cannot be handled. In this case, the probability of overload in the
LTE network is high, and the access success rate and the total
throughput are low.
If the InterFreqBlindMlbSwitch option is deselected, inter-frequency
blind MLB is disabled. Then, when the load in the local cell is heavy
and there is an imbalance in the load between inter-RAT
neighboring cells, the probability of overload in the LTE network is
high, and the access success rate and general network throughput
are low. If this option is selected, inter-frequency blind MLB is
enabled. When the load in the local cell is heavy and the load in the
inter-frequency neighboring cell is light, the probability of overload in
the LTE network is low, and the access success rate and the total
throughput are high.
After the InterFreqIdleMlbSwitch option is deselected, inter-
frequency MLB for UEs in idle mode is disabled and therefore only
handovers of UEs in connected mode can be performed to solve
load imbalance between carriers. After this option is selected, inter-
frequency MLB for UEs in idle mode is enabled, and UEs in idle
mode can be evenly distributed among carriers. This potentially
helps achieve pre-balancing of UEs.
If the MlbLoadInfoSwitch option is selected, the serving cell can
learn load status of inter-RAT neighboring cells. This prevents UEs
from being handed over to a heavily loaded inter-RAT neighboring
cell and therefore avoids QoS deterioration of subscribers.
If the InterFreqIdleMlbSwitch option is selected, inter-frequency cells
provide contiguous coverage in an area, and UEs in the coverage
area support all frequencies in the area, these UEs will be
distributed among the frequencies based on the preset proportions.
If VoIP services are overloaded in multi-band and multi-RAT
networks, selecting the VoIPOffloadSwitch option can increase the
initial E-RAB setup success rate of VoIP services when the
admission function is activated, and decrease the packet loss rate
and delay of VoIP services when the admission function is not
activated. Deselecting the VoIPOffloadSwitch option has no impact
on network performance.
Applicable Mode: L

DlPcAlgoSwitch Downlink Meaning: Indicates whether to enable power control for the PDSCH,
power PDCCH, and PHICH. PdschSpsPcSwitch: If this option is
control deselected, power is allocated evenly during semi-persistent
algorithm scheduling on the PDSCH. If this option is selected, power control is
switch applied during semi-persistent scheduling on the PDSCH, ensuring
quality (indicated by IBLER) of VoIP services in the QPSK
modulation scheme. PhichInnerLoopPcSwitch: Indicates whether to
enable PHICH inner-loop power control. If this option is deselected,
only the initial transmit power for the PHICH is set. If this option is
selected, the eNodeB controls the physical channel transmit power
to enable the receive SINR to converge to the target SINR.
PdcchPcSwitch: Indicates whether to enable PDCCH power control.
If this option is deselected, power is allocated evenly on the
PDCCH. If this option is selected, power allocated to PDCCH is
adjusted dynamically. EDlMaxTXPwrSwitch: If this option is
deselected, the maximum TX power of the cell is determined by the
RS power and the scaling factor indexes Pa and Pb. If this option is
selected, the maximum TX power of the cell can be increased to
improve the RB usage in the cell. This option has no impact on 10
MHz, 15 MHz and 20 MHz LTE TDD cells. BFModeUserPwrSwitch:
Indicates whether to enable power optimization for beamforming
UEs. If this option is deselected, the original power allocation
scheme is adopted for beamforming UEs. If this option is selected,
the eNodeB uses the configured power headroom to increases the
power for beamforming UEs. This option applies only to LTE TDD
networks. SigPowerIncreaseSwitch: Indicates whether to enable
signaling power improvement. If this option is selected, the PDSCH
transmit power increases when scheduling is performed for downlink
retransmission of signaling during network entry. This option applies
only to LTE TDD cells. BFModeUserAdptPwrSwitch: Indicates
whether to enable power adaptation for beamforming UEs. If this
option is selected, the cell adaptively increases the power of
beamforming UEs based on the available power of the RRU and
loads at neighboring cell edges. In this way, the average cell
throughput increases. This option applies only to LTE TDD
networks.
DisuseStatement: This PdschSpsPcSwitch option will be removed in
later versions. In this version, the setting of this option is still
synchronized between the U2000 and the eNodeB and can be
delivered to the eNodeB, but it is no longer used internally.
Therefore, avoid using this option.
GUI Value Range: PdschSpsPcSwitch, PhichInnerLoopPcSwitch,
PdcchPcSwitch, EDlMaxTXPwrSwitch, BFModeUserPwrSwitch,
SigPowerIncreaseSwitch, BFModeUserAdptPwrSwitch
Unit: None
Actual Value Range: PdschSpsPcSwitch, PhichInnerLoopPcSwitch,
PdcchPcSwitch, EDlMaxTXPwrSwitch, BFModeUserPwrSwitch,
SigPowerIncreaseSwitch, BFModeUserAdptPwrSwitch
MML Default Value: None
Recommended Value: PdschSpsPcSwitch:Off,
PhichInnerLoopPcSwitch:Off,
PdcchPcSwitch:On,
EDlMaxTXPwrSwitch:On for single-mode single-carrier RRUs, and
EDlMaxTXPwrSwitch:On for multi-mode RRUs or multi-carrier RRUs
so that system performance is not affected.
BFModeUserPwrSwitch:Off,
SigPowerIncreaseSwitch:Off,
BFModeUserAdptPwrSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If PdschSpsPcSwitch is on,
PDSCH power is adjusted dynamically to ensure PDSCH
demodulation performance and BLER so as to improve PDSCH
performance.
If PhichInnerLoopPcSwitch is on, PHICH transmit power may be
saved but uplink rates may decrease in some scenarios.
If PdcchPcSwitch is on, the service drop rate of cell edge users
(CEUs) decreases and the CEU throughput increases.
If EDlMaxTXPwrSwitch is on, the maximum cell transmit power
increases, which increases the cell RB usage and downlink
throughput.
If DlPcAlgoSwitch is on, the PDSCH transmit power increases when
scheduling is performed for downlink retransmission of signaling
during network entry, and the signaling demodulation performance is
improved. However, the scheduling of downlink RB resources
cannot be completed due to insufficient PDSCH transmit power, the
downlink throughput decreases, and the inter-cell downlink
interference increases. This switch applies only to LTE TDD
networks.
If BFModeUserAdptPwrSwitch is turned on to adaptively increase
the power of beamforming UEs in the serving cell, the downlink
throughput of beamforming UEs and average cell throughput
increase. However, this slightly increases the interference to CEUs
in neighboring cells.
Applicable Mode: L
UlPcAlgoSwitch Uplink Meaning: Indicates whether to enable power control for the PUSCH
power or PUCCH. This parameter includes the following options:
control CloseLoopSpsSwitch: Indicates whether to enable closed-loop
algorithm power control for the PUSCH in semi-persistent scheduling mode. If
switch this option is selected, TPC commands are adjusted based on
correctness of the received initial-transmission packets to decrease
the IBLER.
InnerLoopPuschSwitch: Indicates whether to enable inner-loop
power control for the PUSCH in dynamic scheduling mode. Inner-
loop power control for the PUSCH in dynamic scheduling mode is
enabled only when this option is selected.
InnerLoopPucchSwitch: Indicates whether to enable inner-loop
power control for the PUCCH. Inner-loop power control for the
PUCCH is enabled only when this option is selected.
CloseLoopOptPUSCHSwitch: Indicates whether to enable the
optimization on closed-loop power control for the PUSCH in dynamic
scheduling mode. The optimization is enabled only when this option
is selected. This option applies only to LTE TDD.
PucchPcDtxSinrSwitch: Indicates whether the eNodeB processes
the measured uplink SINR in the DTX state when the PUCCH DTX
is detected. If this option is deselected, the eNodeB does not
process the measured uplink SINR in the DTX state when the
PUCCH DTX is detected. If this option is selected, the eNodeB
processes the measured uplink SINR even when PUCCH DTX is
detected, generates power control commands based on the SINR,
and delivers the power control commands to UEs.
PuschIoTCtrlSwitch: Indicates whether to enable interference control
in closed-loop power control for the PUSCH in dynamic scheduling
mode. Interference control in closed-loop power control for the
PUSCH in dynamic scheduling mode is enabled only when this
option is selected.
SrsPcSwitch: Indicates whether to enable SRS power control
adjustment. SRS power control adjustment is enabled only when
this option is selected. This option applies only to LTE TDD.
NearPointUeOptPUSCHSwitch: Indicates whether to apply
optimized closed-loop power control for the PUSCH to UEs near the
cell center. The optimization helps UEs near the cell center to avoid
unnecessary power lowering due to inter-RAT or abrupt
interference. If this option is selected, optimized closed-loop power
control for the PUSCH is applied to UEs near the cell center. If this
option is deselected, optimized closed-loop power control for the
PUSCH is not applied to UEs near the cell center. This option
applies only to LTE FDD.
PuschRsrpHighThdSwitch: Indicates whether closed-loop power
control for the PUSCH limits the maximum value of RSRP. If this
option is deselected, closed-loop power control for the PUSCH does
not limit the maximum value of RSRP. If this option is selected, the
maximum value of RSRP cannot exceed the RSRP value specified
by the PuschRsrpHighThd parameter in the CellPcAlgo MO. This
option applies only to LTE FDD.
OuterLoopPucchSwitch: Indicates whether to enable outer-loop
PUCCH power control. Outer-loop PUCCH power control is enabled
only when this option is selected.
PucchInitialPcSwitch: Indicates whether to apply fast PUCCH power
control on newly accessed UEs. Fast PUCCH power control is
applied to newly accessed UEs only when this option is selected.
This option applies only to LTE FDD.
GroupPCForPucchSwitch: Indicates whether to enable power
control for the PUCCH group in dynamic scheduling. This option
requires that UEs support PUCCH group power control and applies
only to LTE TDD.
GUI Value Range: CloseLoopSpsSwitch(CloseLoopSpsSwitch),
InnerLoopPuschSwitch(InnerLoopPuschSwitch),
InnerLoopPucchSwitch(InnerLoopPucchSwitch),
CloseLoopOptPUSCHSwitch(CloseLoopOptPUSCHSwitch),
PucchPcDtxSinrSwitch(PucchPcDtxSinrSwitch),
PuschIoTCtrlSwitch(PuschIoTCtrlSwitch),
SrsPcSwitch(SrsPcSwitch),
NearPointUeOptPUSCHSwitch(NearPointUeOptPUSCHSwitch),
PuschRsrpHighThdSwitch(PuschRsrpHighThdSwitch),
OuterLoopPucchSwitch(OuterLoopPucchSwitch),
PucchInitialPcSwitch(PucchInitialPcSwitch),
GroupPCForPucchSwitch(GroupPCForPucchSwitch)
Unit: None
Actual Value Range: CloseLoopSpsSwitch, InnerLoopPuschSwitch,
InnerLoopPucchSwitch, CloseLoopOptPUSCHSwitch,
PucchPcDtxSinrSwitch, PuschIoTCtrlSwitch, SrsPcSwitch,
NearPointUeOptPUSCHSwitch, PuschRsrpHighThdSwitch,
OuterLoopPucchSwitch, PucchInitialPcSwitch,
GroupPCForPucchSwitch
MML Default Value: None
Recommended Value: CloseLoopSpsSwitch:Off,
InnerLoopPuschSwitch:On, InnerLoopPucchSwitch:On,
CloseLoopOptPUSCHSwitch:Off, PucchPcDtxSinrSwitch:On,
PuschIoTCtrlSwitch:Off, SrsPcSwitch:On,
NearPointUeOptPUSCHSwitch:Off, PuschRsrpHighThdSwitch:Off,
OuterLoopPucchSwitch:Off, PucchInitialPcSwitch:Off,
GroupPCForPucchSwitch:Off
Parameter Relationship:
-Configuration constraints:
In the CellAlgoSwitch MO, when the PucchPcDtxSinrSwitch in
UlPcAlgoSwitch is ON, the InnerLoopPucchSwitch in
UlPcAlgoSwitch must be ON.
In the cell, when the PucchInitialPcSwitch in UlPcAlgoSwitch in
CellAlgoSwitch is ON, the InnerLoopPucchSwitch in UlPcAlgoSwitch
in the CellAlgoSwitch must be ON.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: CloseLoopSpsSwitch: If the
SpsSchSwitch option of the UlSchSwitch parameter is selected,
selecting the CloseLoopSpsSwitch option can achieve better VoIP
service performance. If the SpsSchSwitch option of the UlSchSwitch
parameter is deselected, you are advised to deselect the
CloseLoopSpsSwitch option.
InnerLoopPuschSwitch: If this option is selected, the throughput
increases for UEs at a medium distance from the cell center and cell
edge users (CEUs). If this option is deselected, the throughput
decreases for these UEs.
InnerLoopPucchSwitch: If this option is selected, the downlink data
rate for UEs can be guaranteed and the interference in the network
decreases. If this option is deselected, the interference in the
network increases.
PuschIoTCtrlSwitch: If this option is selected and the network is
heavily loaded, uplink interference decreases. As a result, uplink
throughput of CEUs increases, but uplink throughput of CCUs
decreases. If this option is deselected and the network is heavily
loaded, opposite effects are generated.
SrsPcSwitch: If this option is selected, the data rate of UEs with
downlink beamforming or CoMP enabled increases, and the SRS
interference decreases.
NearPointUeOptPUSCHSwitch: If this option is deselected, UEs
near the cell center unnecessarily lower PUSCH transmit power in
inter-RAT or abrupt interference scenarios, decreasing uplink
throughput.
If this option is selected, UEs near the cell center increase the
PUSCH transmit power in inter-RAT or abrupt interference
scenarios, increasing uplink throughput. However, this also
increases uplink interference on neighboring cells.
PuschRsrpHighThdSwitch: If this option is deselected and the
transmit power for the PUSCH is too high, the uplink received power
(if any) is saturated. As a result, uplink demodulation performance
deteriorates.
If this option is selected, uplink received power saturation (if any)
can be prevented and uplink demodulation performance can be
guaranteed.
OuterLoopPucchSwitch: If this option is selected and the channel
quality of the PUCCH in format 2x is poor, the PUCCH transmit
power increases, the false detection rate on the PUCCH in format 2x
decreases, and downlink throughput increases.
If this option is deselected and the channel quality of the PUCCH in
format 2x is poor, the PUCCH transmit power cannot be increased,
the false detection rate on the PUCCH in format 2x increases, and
downlink throughput cannot be increased.
PucchInitialPcSwitch: If this option is selected, the PUCCH transmit
power of newly accessed UEs can be rapidly decreased, which
decreases PUCCH interference on neighboring cells and increases
downlink throughput.
If this option is deselected, the PUCCH transmit power of newly
accessed UEs cannot be rapidly decreased, which cannot rapidly
decrease PUCCH interference on neighboring cells or increase
downlink throughput.
GroupPCForPucchSwitch: If this option is selected, PUCCH power
converges relatively rapidly, power consumption of UEs is relatively
low, and PUCCH interference to neighboring cells is relatively weak.
Deselecting this option results in the opposite effects.
PucchPcDtxSinrSwitch: If this option is selected, the PUCCH
transmit power increases in severe interference scenarios to ensure
proper PUCCH demodulation. Improved PUCCH demodulation
performance increases the service success rate, handover success
rate, and downlink data rate in the cell; however, the power increase
may cause interference to neighboring cells. If this option is
deselected, PUCCH demodulation may fail due to extremely low UE
transmit power in severe interference scenarios.
Applicable Mode: L

BfAlgoSwitch BF Meaning: Indicates whether to enable or disable the beamforming


algorithm algorithm. If this BfSwitch option is selected, the beamforming
switch algorithm is used for all UEs in a specific cell. If this option is
deselected, the beamforming algorithm is not used for all UEs in a
specific cell. The beamforming algorithm is disabled by default. If a
cell supporting beamforming is established, manually enable the
beamforming algorithm. This option applies only to LTE TDD
networks.
GUI Value Range: BfSwitch
Unit: None
Actual Value Range: BfSwitch
MML Default Value: None
Recommended Value: BfSwitch:Off
Parameter Relationship:
-Configuration constraints:
In the CellAlgoSwitch, SsrdAlgoSwitch is set to On only when
BfAlgoSwitch has been set to On.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

DlSchSwitch DL Meaning: Indicates whether to enable downlink scheduling


schedule algorithms in a cell. This parameter includes the following options:
switch FreqSelSwitch: Indicates whether to enable frequency-selective
scheduling. If this option is selected, data is transmitted on the
frequency band of high channel quality.
SpsSchSwitch: Indicates whether to enable semi-persistent
scheduling during talk spurts of VoLTE services. If this option is
selected, semi-persistent scheduling is applied during talk spurts of
VoLTE services. If this option is deselected, dynamic scheduling is
applied during talk spurts of VoLTE services.
MBSFNShutDownSwitch: Indicates whether to enable Multimedia
Broadcast multicast service Single Frequency Network (MBSFN)
subframe shutdown. If this option is selected, MBSFN subframe
shutdown is applied. If this option is
deselected, MBSFN subframe shutdown is not applied. This option
takes effect only if the SymbolShutdownSwitch option is selected. If
the MBSFNShutDownSwitch option is selected, the setting of the
switch for mapping SIBs to SI messages becomes invalid. The latter
can be specified by the SiMapSwitch parameter in the CellSiMap
MO. If the MBSFNShutDownSwitch option is deselected, the setting
of the switch for mapping SIBs to SI messages becomes valid. The
MBSFNShutDownSwitch option applies only to LTE-only base
stations.
NonGbrBundlingSwitch: Indicates whether to enable downlink non-
GBR packet bundling. If this option is selected, delay of non-GBR
services can be controlled in non-congestion scenarios. If this option
is deselected, delay of non-GBR services cannot be controlled.
EnAperiodicCqiRptSwitch: Indicates whether to enable enhanced
aperiodic channel quality indicator (CQI) reporting. If this option is
selected, the eNodeB triggers aperiodic CQI reporting for a UE
based on downlink services of the UE and the interval at which the
UE sends periodic CQI reports. If this option is deselected, UEs
under non-frequency-selective scheduling do not trigger aperiodic
CQI reporting based on downlink services and trigger an aperiodic
CQI reporting if no valid periodic CQI reports are sent in eight
consecutive periodic CQI reporting periods.
DlMbrCtrlSwitch: Indicates whether to enable downlink scheduling
based on the maximum bit rate (MBR) and guaranteed bit rate
(GBR) on the GBR bearer. If this option is selected, the eNodeB
performs downlink scheduling on GBR bearers based on the MBR
and GBR. If this option is deselected, the eNodeB performs
downlink scheduling on GBR bearers based on the GBR only.
MbrDlSchSwitch: Indicates whether the eNodeB performs downlink
scheduling based on MBR. If this option is selected, the eNodeB
prioritizes UEs based on the MBRs during downlink scheduling. This
option applies only to LTE TDD. UeAmbrDlSchSwitch: Indicates
whether the eNodeB performs downlink scheduling based on per UE
aggregate maximum bit rates (UE-AMBRs). If this option is selected,
the eNodeB prioritizes UEs based on the UE-AMBRs during
downlink scheduling. This option applies only to LTE TDD.
EpfEnhancedSwitch: Indicates whether to enable the enhanced
proportional fair (EPF) enhancement algorithm for downlink
scheduling. The EPF enhancement algorithm for downlink
scheduling is enabled only when this switch is on.
AperiodicCqiTrigOptSwitch: Indicates whether to optimize triggering
of aperiodic CQI reporting. If this option is selected, a UE performing
initial access triggers aperiodic CQI reporting based on related
trigger conditions after the DLMAC instance has been established
for 200 ms and the eNodeB receives MSG5. Consider that aperiodic
CQI reporting is triggered by invalid CQI reports in eight consecutive
CQI reporting periods. If cyclic redundancy check (CRC) on
aperiodic CQI reports fails, aperiodic CQI reporting is not repeatedly
triggered when DRX is enabled; or aperiodic CQI reporting is
triggered after eight TTIs when DRX is disabled. If this option is
deselected, a UE performing initial access triggers aperiodic CQI
reporting based on related trigger conditions after the DLMAC
instance has been established for 200 ms. Consider that aperiodic
CQI reporting is triggered by invalid CQI reports in eight consecutive
CQI reporting periods. If CRC on aperiodic CQI reports fails,
aperiodic CQI reporting is triggered after eight TTIs regardless of the
DRX status.
VoipTbsBasedMcsSelSwitch: Indicates whether the modulation and
coding scheme (MCS) index is selected based on the transport
block size (TBS) in downlink dynamic scheduling for VoLTE
services. The MCS index is selected based on the TBS in downlink
dynamic scheduling for VoLTE services only if this option is
selected.
PagingInterfRandSwitch: Indicates whether to enable interference
randomization for paging messages. If this option is selected,
interference randomization is enabled for paging messages.
DlSingleUsrMcsOptSwitch: Indicates conditions for lowering the
MCS index for a single UE. If this option is selected, the MCS index
can be lowered for a UE if the UE is the only UE to be scheduled in
a transmission time interval (TTI). If this option is deselected, the
MCS index can be lowered for a UE if the threshold for the function
of lowering the MCS index to increase the number of RBs is reached
and the UE is the only UE to be scheduled in a TTI.
UeSigMcsEnhanceSwitch: Indicates whether to enable MCS
optimization for UE signaling. If this option is selected, MCS
optimization for UE signaling is enabled. For LTE FDD, the MCS
index for UE signaling is the same as the MCS index for data. For
LTE TDD, the MCS index for UE signaling is lowered based on the
MCS index for data. If this option is deselected, a fixed low MCS
index is used for UE signaling.
SubframeSchDiffSwitch: Indicates whether to increase the number
of UEs scheduled in subframes 3 and 8 when uplink-downlink
configuration 2 is used. If this option is selected, the number of UEs
scheduled in subframes 3 and 8 is increased when uplinkd-downlink
configuration 2 is used. If this option is deselected, the scheduling
policy used in subframes 3 and 8 is the same as that used in other
downlink subframes when uplink-downlink configuration 2 is used.
This option applies only to LTE TDD.
TailPackagePriSchSwitch: Indicates whether to enable scheduling of
downlink connected tail packages in the bearer. If this option is
selected, the connected tail package is scheduled preferentially in
the next TTI, which reduces the delay and increases the
transmission rate. If this option is deselected, the scheduling policy
of the connected tail package is the same as other downlink
subframes. This option applies only to LTE TDD.
SIB1InterfRandSwitch: Indicates whether to enable SIB1
interference randomization. If this option is selected, interference
randomization is enabled for SIB1. This option applies only to LTE
TDD.
FreqSelJudgeIgnorDopplerSwitch: Indicates whether to ignore
Doppler conditions. If this option is selected, Doppler conditions are
ignored during frequency selective channel determination. If this
option is deselected, Doppler conditions are considered during
frequency selective channel determination. This option applies only
to LTE FDD.
EnhExtQCISpsSchSwitch: Indicates whether to enable semi-
persistent scheduling during talk spurts of PTT services with
standardized QCI 65, standardized QCI 66, or an enhanced
extended QCI. If this option is selected, semi-persistent scheduling
is applied. If this option is deselected, dynamic scheduling is
applied.
DlVoipBundlingSwitch: Indicates whether to enable active packet
bundling for downlink VoLTE services. Active packet bundling is
enabled for downlink VoLTE services only if this option is selected. If
this option is selected, PDCCH resources can be saved for downlink
data services or uplink services, thereby increasing the VoLTE
capacity in VoLTE-only scenarios or increasing the throughput of
data services in mixed service scenarios. However, the delay in
downlink VoLTE voice packet scheduling will increase and MOSs
may decrease. You are advised to deselect this option if you prefer
VoLTE performance and do not expect MOS reduction.
DlPacketLenAwareSchSw: Indicates whether to enable packet
length awareness performance optimization in the downlink. Packet
length awareness performance optimization is enabled in the
downlink only if this option is selected.
RLCArqFeedbackEnhancedSwitch: Indicates whether to modify the
HARQ feedback results based on the RLC status reports when
subframe configuration 2 is used. If this option is selected, the
eNodeB modifies the HARQ feedback results based on the RLC
status reports after receiving the reports. This prevents unnecessary
HARQ retransmissions. This option applies only to LTE TDD.
PaReconfigOptSwitch: Indicates whether to enable PA
reconfiguration optimization. The optimization is enabled when this
option is selected.RankRapidRptSwitch: Indicates whether to enable
fast rank reporting. If this option is selected, an aperiodic CQI
reporting is immediately triggered after successful network access. If
this option is deselected, an aperiodic CQI reporting is not
immediately triggered after successful network access.
GUI Value Range: FreqSelSwitch(FreqSelSwitch),
SpsSchSwitch(SpsSchSwitch),
MBSFNShutDownSwitch(MBSFNShutDownSwitch),
NonGbrBundlingSwitch(NonGbrBundlingSwitch),
EnAperiodicCqiRptSwitch(EnAperiodicCqiRptSwitch),
DlMbrCtrlSwitch(DlMbrCtrlSwitch),
MbrDlSchSwitch(MbrDlSchSwitch),
UeAmbrDlSchSwitch(UeAmbrDlSchSwitch),
EpfEnhancedSwitch(EpfEnhancedSwitch),
AperiodicCqiTrigOptSwitch(AperiodicCqiTrigOptSwitch),
VoipTbsBasedMcsSelSwitch(VoipTbsBasedMcsSelSwitch),
PagingInterfRandSwitch(PagingInterfRandSwitch),
DlSingleUsrMcsOptSwitch(DlSingleUsrMcsOptSwitch),
SubframeSchDiffSwitch(SubframeSchDiffSwitch),
TailPackagePriSchSwitch(TailPackagePriSchSwitch),
UeSigMcsEnhanceSwitch(UeSigMcsEnhanceSwitch),
FreqSelJudgeIgnorDopplerSwitch(FreqSelJudgeIgnorDopplerSwitch
), SIB1InterfRandSwitch(SIB1InterfRandSwitch),
EnhExtQCISpsSchSwitch(EnhExtQCISpsSchSwitch),
DlVoipBundlingSwitch(DlVoipBundlingSwitch),
DlPacketLenAwareSchSw(DlPacketLenAwareSchSw),
RLCArqFeedbackEnhancedSwitch(RLCArqFeedbackEnhancedSwit
ch), PaReconfigOptSwitch(PaReconfigOptSwitch),
RankRapidRptSwitch(RankRapidRptSwitch)
Unit: None
Actual Value Range: FreqSelSwitch, SpsSchSwitch,
MBSFNShutDownSwitch, NonGbrBundlingSwitch,
EnAperiodicCqiRptSwitch, DlMbrCtrlSwitch, MbrDlSchSwitch,
UeAmbrDlSchSwitch, EpfEnhancedSwitch,
AperiodicCqiTrigOptSwitch, VoipTbsBasedMcsSelSwitch,
PagingInterfRandSwitch, DlSingleUsrMcsOptSwitch,
SubframeSchDiffSwitch, TailPackagePriSchSwitch,
UeSigMcsEnhanceSwitch, FreqSelJudgeIgnorDopplerSwitch,
SIB1InterfRandSwitch, EnhExtQCISpsSchSwitch,
DlVoipBundlingSwitch, DlPacketLenAwareSchSw,
RLCArqFeedbackEnhancedSwitch, PaReconfigOptSwitch,
RankRapidRptSwitch
MML Default Value: None
Recommended Value: FreqSelSwitch:Off, SpsSchSwitch:Off,
MBSFNShutDownSwitch:Off, NonGbrBundlingSwitch:Off,
EnAperiodicCqiRptSwitch:Off, DlMbrCtrlSwitch:Off,
MbrDlSchSwitch:Off, UeAmbrDlSchSwitch:Off,
EpfEnhancedSwitch:Off, AperiodicCqiTrigOptSwitch:On,
VoipTbsBasedMcsSelSwitch:On, DlSingleUsrMcsOptSwitch:Off,
SubframeSchDiffSwitch:Off, TailPackagePriSchSwitch:Off,
UeSigMcsEnhanceSwitch:Off,
FreqSelJudgeIgnorDopplerSwitch:Off, SIB1InterfRandSwitch:On,
EhnExtQCISpsSchSwitch:Off, DlVoipBundlingSwitch:Off,
DlPacketLenAwareSchSw:Off,
RLCArqFeedbackEnhancedSwitch:Off, PaReconfigOptSwitch:Off,
RankRapidRptSwitch:Off
Parameter Relationship:
-Configuration constraints:
OutOfBandRelaySwitch under the RelaySwitch parameter in the
CellAlgoSwitch MO cannot be turned on when
MBSFNShutDownSwitch under the DlSchSwitch parameter is
turned on.
If SuperCombCellSwitch of SfnAlgoSwitch in the CellAlgoSwitch MO
is set to on, SpsSchSwitch of DlSchSwitch in the CellAlgoSwitch MO
must be deselected.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: FreqSelSwitch: If this option
is selected, the subband CQIs reported by UEs are used in downlink
scheduling for UEs that meet the
requirements for frequency selection, thereby increasing the
spectrum efficiency for UEs. If this option is deselected, wideband
CQIs
reported by UEs are used in downlink scheduling for all UEs.
SpsSchSwitch: If this option is selected, the eNodeB performs semi-
persistent scheduling on VoLTE services, and PDCCH resource
overhead and CQI reporting overhead decrease, which increases
the VoLTE
service capacity. If this option is deselected, the eNodeB performs
dynamic scheduling on VoLTE services, and PDCCH resource
overhead
increases. As a result, the VoLTE service capacity decreases, but
the QoS of VoLTE services improves.
MBSFNShutDownSwitch: If this option
is selected, more energy can be conserved, but resource scheduling
delay is prolonged. Deselecting this option results in the opposite
effects.
EnAperiodicCqiRptSwitch: Selecting this option results in timely
reporting of downlink channel quality and increased downlink
data rate. Because more control channel elements (CCEs) are
consumed by aperiodic CQI reporting, it is recommended that the
PdcchSymNumSwitch parameter be set to ECfiAdaptionON to
decrease the number of symbols consumed by enhanced aperiodic
CQI reporting,
thereby further increasing downlink data rates. Deselecting this
option has no impact on network performance.
DlMbrCtrlSwitch: If this
option is selected, the eNodeB allocates more RBs to downlink GBR
services if the MBR is greater than the GBR and a GBR bearer is
set up
for a UE, thereby increasing the downlink traffic volume on the GBR
bearer. If the MBR is equal to the GBR and only the non-GBR
bearer
is set up for a UE, selecting this option has no impact on network
performance. If the MBR is equal to the GBR and a GBR bearer is
set
up for a UE: (1) Selecting this option has no impact on network
performance when RBs for downlink services are sufficient. (2) Non-
GBR
services are affected by GBR services if this option is selected when
RBs for downlink services are insufficient. If this option is
deselected, the eNodeBs performs scheduling based only on the
GBR for downlink GBR bearers and network performance is not
affected.
MbrDlSchSwitch/UeAmbrDlSchSwitch: If this option is selected,
throughput of UEs with greater MBR/AMBR increases, and
throughput of UEs
with smaller MBR/AMBR decreases. In addition, system throughput
may also be affected by the differences between MBRs/AMBRs of
UEs and
the distribution of UEs in the cell. If this option is deselected, the
throughput differences between UEs with different MBRs/AMBRs
decrease. In addition, system throughput is not affected by the
differences between MBRs/AMBRs of UEs or the distribution of UEs
in the
cell.
EpfEnhancedSwitch: If this option is selected, downlink user
throughput increases and user experience improves. Deselecting
this
option has no impact on network performance.
AperiodicCqiTrigOptSwitch: If this option is selected, PDCCH
resources to be consumed are
reduced and downlink throughput increases. Deselecting this option
has no impact on network performance.
VoipTbsBasedMcsSelSwitch: If
this option is selected, the number of hybrid automatic repeat
request (HARQ) retransmissions for VoIP services decreases and
the
scheduling delay of UEs in and near the cell center is reduced.
PagingInterfRandSwitch: If this option is selected, the paging
success
rate increases, but other KPIs may slightly deteriorate, including the
access success rate, handover success rate, service drop rate,
handover delay, access delay, and PRB usage. If this option is
deselected, the paging success rate decreases, but the preceding
KPIs do
not deteriorate.
DlSingleUsrMcsOptSwitch: If this option is selected and the load is
low, the local cell throughput increases; however,
the interference with neighboring cells increases, the neighboring
cell throughput decreases, and the IBLER increases. Deselecting
this
option has no impact on network performance.
UeSigMcsEnhanceSwitch: If this option is selected, UE throughput
increases and UE MCS
distribution improves. However, the service drop rate may slightly
increase and the RRC connection reestablishment success rate may
slightly decrease. In addition, the outgoing handover success rate
and E-RAB setup success rate may also slightly decrease in LTE
FDD
cells. If this option is deselected, UE throughput decreases and UE
MCS distribution deteriorates. However, the service drop rate
decreases and the RRC connection reestablishment success rate
increases. In addition, the handover success rate and E-RAB setup
success
rate increase in LTE FDD cells.
SubframeSchDiffSwitch: If this option is selected, the number of
uplink UEs scheduled increases but the
number of downlink UEs scheduled decreases. As a result, the
uplink PRB usage increases but the downlink PRB usage may
decrease
slightly. If this option is deselected, the number of uplink scheduled
UEs decreases and the uplink PRB usage decreases accordingly.
TailPackagePriSchSwitch: If this option is selected, the connected
tail package is scheduled preferentially in the next TTI, which
shortens the delay and increases the transmission rate. If this option
is deselected, the connected tail package is not scheduled
preferentially in the next TTI, which prolongs the delay and
decreases the perceived data rate.
SIB1InterfRandSwitch: If this option is
selected, the RBs scheduled for SIB1 do not overlap between
neighboring cells. The interference caused by the RBs for SIB1s of
the
neighboring cells to the same target cell is evenly distributed on the
entire band. In this way, the SIB1 demodulation capability in the
target cell is improved, reducing the service drops caused by SIB1
demodulation failures. If this option is deselected, the RBs
scheduled for neighboring cells overlap.
FreqSelJudgeIgnorDopplerSwitch: If this option is selected, Doppler
conditions are ignored
during frequency selective channel determination, which is applied
when there are more low-speed UEs and increases gains in
downlink
frequency-selective scheduling. If this option is deselected, Doppler
conditions are considered during frequency selective channel
determination, which is applied when there are more high-mobility
UEs and avoids the negative gains during frequency-selective
scheduling on high-mobility UEs.
EnhExtQCISpsSchSwitch: If this option is selected, the eNodeB
performs semi-persistent scheduling on PTT services with
standardized QCI
65 or 66, and PDCCH resource overhead and CQI reporting
overhead decrease, which increases the PTT UE capacity in unicast
mode. If this
option is deselected, the eNodeB performs dynamic scheduling on
PTT services with standardized QCI 65 or 66, and PDCCH resource
overhead
increases. As a result, the PTT UE capacity decreases in unicast
mode, but the QoS of PTT services improves.
DlVoipBundlingSwitch: If
this option is selected, active packet bundling is performed on
downlink VoLTE services, which saves PDCCH resources. If
PDCCH resources
are limited: (1) For single VoLTE services, the saved PDCCH
resources can be used in the uplink to increase VoLTE capacity.
However, the
delay in downlink voice packet scheduling is prolonged, which may
reduce MOSs. (2) For mixed services, the saved PDCCH resources
can be
used by downlink data services or uplink services, which may
increase the throughput of both uplink and downlink data services. If
PDCCH
resources are not limited, the delay in downlink voice packet
scheduling will increase, which may cause MOS decrease but does
not affect
data services.
Deselecting this option has no impact on network performance.
DlPacketLenAwareSchSw: If this option is deselected, packet
length awareness performance optimization is disabled in the
downlink, and the network performance is not affected. If this option
is
selected, packet length awareness performance optimization is
enabled in the downlink, and downlink perceived throughput
increases when
the network is in heavy or medium loads in the downlink. If the
downlink PRB usage is greater than 90% and the number of
RRC_CONNECTED
UEs in the cell is large (for example, more than 150), selecting this
option may generate negative gains less than 2%.
RLCArqFeedbackEnhancedSwitch: If this option is selected,
unnecessary HARQ retransmissions are prevented, saving downlink
RB resources
and improving downlink throughput. However, extra uplink PRBs are
required for UEs to frequently send RLC status reports, and
therefore
uplink throughput may slightly decrease.
If this option is deselected, unnecessary HARQ retransmissions may
occur in the downlink. As a
result, downlink PRBs are wasted and downlink throughput may
decrease.
PaReconfigOptSwitch: If this option is selected, the PA
reconfiguration time is reduced and the UE throughput during PA
reconfiguration is increased. Deselecting this option has no impact
on
downlink performance.
RankRapidRptSwitch: When this option is selected, the eNodeB can
quickly obtain rank information, increasing the probability of
scheduling using a rank higher than 1. However, PUSCH resource
consumption increases, slightly decreasing the uplink data rate.
When
this option is deselected, uplink and downlink performance is not
affected.
Applicable Mode: L

UlSchSwitch Uplink Meaning: This parameter indicates the switches related to uplink
schedule (UL) scheduling in the cell. The switches are used to enable or
switch disable specific UL scheduling functions. SpsSchSwitch: Indicates
whether to enable semi-persistent scheduling during talk spurts of
VoLTE services. If this option is selected, semi-persistent scheduling
is applied during talk spurts of VoLTE services. If this option is
deselected, dynamic scheduling is applied during talk spurts of
VoLTE services.
SinrAdjustSwitch: Indicates whether to adjust the measured signal to
interference plus noise ratio (SINR) based on ACK/NACK in UL
hybrid automatic repeat request (HARQ) processes.
PreAllocationSwitch: Indicates whether to enable preallocation in the
uplink. If this option is selected: (1) If the SmartPreAllocationSwitch
option is deselected and a UE is in the discontinuous reception
(DRX) state, preallocation is disabled for the UE in the uplink; (2) If
the SmartPreAllocationSwitch option is deselected and the UE is not
in the DRX state, preallocation is enabled for the UE in the uplink;
(3) If the SmartPreAllocationSwitch option is selected and the
SmartPreAllocationDuration parameter value is greater than 0,
smart preallocation is enabled for the UE in the uplink; (4) If the
SmartPreAllocationSwitch option is selected and the
SmartPreAllocationDuration parameter value is 0, preallocation is
disabled for the UE in the uplink. If this option is deselected,
preallocation is disabled for the UE in the uplink. If bearer-level
preallocation or bearer-level smart preallocation is enabled for a
QCI, cell-level preallocation and cell-level smart preallocation do not
apply to UEs with the QCI.
UlVmimoSwitch: Indicates whether to enable multi-user MIMO (MU-
MIMO) in the UL. If this option is selected, the eNodeB performs
MU-MIMO pairing among UEs based on related principles. UEs
forming a pair transmit data using the same time-frequency
resources, which improves system throughput and spectral
efficiency.
TtiBundlingSwitch: Indicates whether to enable transmission time
interval (TTI) bundling. If TTI bundling is enabled, more transmission
opportunities are available to UEs within the delay budget for VoLTE
services on the Uu interface, thereby improving uplink coverage.
ImIcSwitch: Indicates whether to enable the intermodulation
interference (IM) cancellation for UEs. When data is transmitted in
both uplink and downlink, two IM components are generated
symmetrically beside the Direct Current (DC) subcarrier on the
downlink receive channel due to interference from uplink radio
signals. If this option is selected, IM component elimination is
performed on UEs. If this option is deselected, IM component
elimination is not performed on UEs. This option applies only to FDD
cells working in frequency band 20.
SmartPreAllocationSwitch: Indicates whether to enable uplink smart
preallocation when preallocation is enabled (by selecting
PreAllocationSwitch). If both the PreAllocationSwitch and
SmartPreAllocationSwitch options are selected and
SmartPreAllocationDuration is set to a value greater than 0, uplink
smart preallocation is enabled. Otherwise, uplink smart preallocation
is disabled.
PuschDtxSwitch: Indicates whether the eNodeB uses the physical
uplink shared channel (PUSCH) discontinuous transmission (DTX)
detection result during UL scheduling. In an LTE FDD cell, if this
option is selected, based on the PUSCH DTX detection result, the
eNodeB determines whether to perform adaptive retransmission
during UL scheduling and also adjusts the control channel element
(CCE) aggregation level of the physical downlink control channel
(PDCCH) carrying downlink control information (DCI) format 0. If an
FDD cell is established on an LBBPc, this option takes effect only if
the cell uses less than four RX antennas and normal cyclic prefix
(CP) in the uplink and the SrsCfgInd parameter in the SRSCfg MO is
set to BOOLEAN_TRUE. Note that the LBBPc does not support
PUSCH DTX detection for UEs with MU-MIMO applied. In an LTE
TDD cell, this option takes effect only when the cell is configured
with subframe configuration 2 or 5. After this option takes effect, the
eNodeB adjusts the CCE aggregation level based on the PUSCH
DTX detection results. Note that LTE TDD cells established on
LBBPc boards do not support PUSCH DTX detection.
UlIblerAdjustSwitch: Indicates whether to enable the uplink IBLER
adjustment algorithm. If this option is selected, the target IBLER is
adjusted for CEUs in TDD cells to increase the cell edge throughput.
If this option is selected independently for FDD cells, the algorithm
does not take effect.
UlEnhancedFssSwitch: Indicates whether to enable uplink load-
based enhanced frequency selective scheduling. This option applies
only to FDD cells.
UlIicsAlgoSwitch: Indicates whether to enable the UL IICS algorithm.
If this option is selected, interference can be reduced based on
accurate detection of user attributes and resource scheduling
coordination, thereby increasing the cell edge throughput. This
option applies only to LTE TDD.
UlEnhancedSrSchSwitch: Indicates whether uplink re-scheduling is
performed only when the On Duration timer for the DRX long cycle
starts. Uplink re-scheduling is required if the number of HARQ
retransmissions for a scheduling request (SR) reaches the
maximum value but the scheduling still fails. If this option is
selected, uplink re-scheduling is performed only when the On
Duration timer for the DRX long cycle starts. If this option is
deselected, uplink re-scheduling is performed immediately when the
number of HARQ retransmissions for SR reaches the maximum
value but the scheduling still fails. It is recommended that this option
be selected in live networks.
SchedulerCtrlPowerSwitch: Indicates whether the uplink scheduler
performs scheduling without considering power control restrictions. If
this option is selected, the uplink scheduler performs scheduling
without considering power control restrictions, which ensures full
utilization of the transmit power for all UEs. If this option is
deselected, the uplink scheduler considers power control restrictions
while performing scheduling, which prevents full utilization of the
transmit power for UEs at far or medium distances from the cell
center.
UlMinGbrSwitch: Indicates whether to enable uplink minimum
guaranteed bit rate (GBR). If this option is selected, the minimum
GBR of non-GBR services is ensured by increasing the scheduling
priority of UEs whose non-GBR service rates are lower than the
minimum GBR of GBR services.
UlMbrCtrlSwitch: Indicates whether to enable uplink scheduling
based on the maximum bit rate (MBR) and guaranteed bit rate
(GBR) on the GBR bearer. If this option is selected, the eNodeB
performs uplink scheduling on GBR bearers based on the MBR and
GBR. If this option is deselected, the eNodeB performs uplink
scheduling on GBR bearers based only on the GBR.
MbrUlSchSwitch: Indicates whether the eNodeB performs uplink
scheduling based on MBR. If this option is selected, the eNodeB
prioritizes UEs based on the MBRs during uplink scheduling. This
option applies only to LTE TDD.
UeAmbrUlSchSwitch: Indicates whether the eNodeB performs uplink
scheduling based on the aggregate maximum bit rate (AMBR) of
UEs. If this option is selected, the eNodeB prioritizes UEs based on
the UE-AMBRs during uplink scheduling. This option applies only to
LTE TDD.
UlEnhancedDopplerSwitch: Indicates whether to enable enhanced
uplink scheduling based on mobility speed. If this option is selected,
enhanced uplink scheduling based on mobility speed is enabled. In
enhanced uplink scheduling based on mobility speed, the eNodeB
uses Doppler measurement results to determine low-speed UEs to
further improve UL performance of low-speed UEs. If this option is
deselected, enhanced uplink scheduling based on mobility speed is
disabled. Enhanced uplink scheduling based on mobility speed
takes effect only when the DopMeasLevel parameter is set to
CLASS_1 and the UlEnhancedDopplerSwitch option is selected.
This option does not take effect on cells established on an LBBPc.
UlRaUserSchOptSw: Indicates whether the eNodeB raises the
scheduling priority of UEs sending uplink access signaling, including
MSG5 and the RRC Connection Reconfiguration Complete
message. If this option is selected, the eNodeB raises the
scheduling priority of UEs sending uplink access signaling. If this
option is deselected, the eNodeB does not raise the scheduling
priority of UEs sending uplink access signaling.
UlLast2RetransSchOptSwitch: Indicates whether to enable
optimization on the scheduling policy for the last two
retransmissions. If this option is selected, optimization on the
scheduling policy for the last two retransmissions is enabled. If the
UE transmit power is not limited, adaptive retransmission is used
and the number of RBs increases in the last two retransmissions to
increase the receive success rate of the last two retransmissions
and decrease uplink RBLER. If this option is deselected,
optimization on the scheduling policy for the last two retransmissions
is disabled.
UlInterfFssSwitch: Indicates whether to enable interference-based
uplink frequency-selective scheduling. This parameter applies only
to LTE FDD.
UlSmallRBSpectralEffOptSw: Indicates whether to enable spectral
efficiency optimization on uplink small RBs. If this option is selected,
the optimization is enabled, thereby ensuring that the transmission
block size calculated based on optimized spectral efficiency is not
less than the traffic volume to be scheduled. If this option is
deselected, the optimization is disabled.
PuschUsePucchRbSwitch: Indicates whether PUCCH RBs can be
occupied by the PUSCH. In scenarios with a single user, if this
option is selected, PUCCH RBs can be occupied by the PUSCH. If
this option is deselected, PUCCH RBs cannot be occupied by the
PUSCH. In scenarios with multiple users, PUCCH RBs cannot be
occupied by the PUSCH regardless of whether this option is
selected.
PuschDtxSchOptSwitch: If this option is selected, the eNodeB
determines whether to perform adaptive retransmission during UL
scheduling based on the PUSCH DTX detection result. This option
takes effect only when subframe configuration 2 or 5 is used. If a
TDD cell is established on an LBBPc, PUSCH DTX detection is not
supported. This option applies only to TDD cells.
PrachRbReuseSwitch: If this option is selected, the PUSCH and
PRACH transmissions can use the same resource. If this option is
deselected, the PUSCH and PRACH transmissions cannot use the
same resource. This option applies only to TDD cells.
ULFSSAlgoswitch: If this option is deselected, uplink frequency-
selective scheduling is disabled. If this option is selected, uplink
frequency-selective scheduling is enabled. This option applies only
to LTE TDD.
SrSchDataAdptSw: Indicates whether to enable data volume
adaption in SR scheduling. Data volume adaption in SR scheduling
is enabled only when this option is selected. This option applies only
to LTE FDD cells.
UlFssUserThdStSwitch: Indicates whether to enable the optimization
policy on the UE number threshold for frequency selective
scheduling. The optimization policy is enabled only when this option
is selected.
HighOrderVMIMOSwitch: Indicates whether to enable high-order
VMIMO. High-order VMIMO is enabled only when this option is
selected. This option applies only to TDD cells.
VMIMOReduceMCSRiseRBSwitch: Indicates whether VMIMO
pairing is performed for UEs whose MCS index is reduced to
increase the number of RBs. VMIMO is performed for UEs whose
MCS index is reduced to increase the number of RBs only when this
option is selected. This option applies only to TDD cells.
VoLTEUeVmimoSwitch: Indicates whether VMIMO pairing is
performed for VoLTE UEs. VMIMO pairing is performed for VoLTE
UEs only when this option is selected. This option applies only to
TDD cells.
DisuseStatement: This ImIcSwitch option will be removed in later
versions. In this version, the setting of this option is still
synchronized between the U2000 and the eNodeB and can be
delivered to the eNodeB, but it is no longer used internally.
Therefore, avoid using this option.
GUI Value Range: SpsSchSwitch(SpsSchSwitch),
SinrAdjustSwitch(SinrAdjustSwitch),
PreAllocationSwitch(PreAllocationSwitch),
UlVmimoSwitch(UlVmimoSwitch),
TtiBundlingSwitch(TtiBundlingSwitch), ImIcSwitch(ImIcSwitch),
SmartPreAllocationSwitch(SmartPreAllocationSwitch),
PuschDtxSwitch(PuschDtxSwitch),
UlIblerAdjustSwitch(UlIblerAdjustSwitch),
UlEnhancedFssSwitch(UlEnhancedFssSwitch),
UlEnhancedSrSchSwitch(UlEnhancedSrSchSwitch),
SchedulerCtrlPowerSwitch(SchedulerCtrlPowerSwitch),
UlIicsAlgoSwitch(UlIicsAlgoSwitch),
UlMinGbrSwitch(UlMinGbrSwitch),
UlMbrCtrlSwitch(UlMbrCtrlSwitch),
MbrUlSchSwitch(MbrUlSchSwitch),
UeAmbrUlSchSwitch(UeAmbrUlSchSwitch),
UlEnhancedDopplerSwitch(UlEnhancedDopplerSwitch),
UlRaUserSchOptSw(UlRaUserSchOptSw),
UlLast2RetransSchOptSwitch(UlLast2RetransSchOptSwitch),
UlInterfFssSwitch(UlInterfFssSwitch),
UlSmallRBSpectralEffOptSw(UlSmallRBSpectralEfficiencyOptSw),
PuschUsePucchRbSwitch(PuschUsePucchRbSwitch),
PuschDtxSchOptSwitch(PuschDtxSchOptSwitch),
ULFSSAlgoSwitch(ULFSSAlgoSwitch),
PrachRbReuseSwitch(PrachRbReuseSwitch),
SrSchDataAdptSw(SrSchDataAdptSw),
UlFssUserThdStSwitch(UlFssUserThdStSwitch),
HighOrderVMIMOSwitch(HighOrderVMIMOSwitch),
VMIMOReduceMCSRiseRBSwitch(VMIMOReduceMCSRiseRBSwit
ch), VoLTEUeVmimoSwitch(VoLTEUeVmimoSwitch)
Unit: None
Actual Value Range: SpsSchSwitch, SinrAdjustSwitch,
PreAllocationSwitch, UlVmimoSwitch, TtiBundlingSwitch,
ImIcSwitch, SmartPreAllocationSwitch, PuschDtxSwitch,
UlIblerAdjustSwitch, UlEnhancedFssSwitch,
UlEnhancedSrSchSwitch, SchedulerCtrlPowerSwitch,
UlIicsAlgoSwitch, UlMinGbrSwitch, UlMbrCtrlSwitch,
MbrUlSchSwitch, UeAmbrUlSchSwitch, UlEnhancedDopplerSwitch,
UlRaUserSchOptSw, UlLast2RetransSchOptSwitch,
UlInterfFssSwitch, UlSmallRBSpectralEffOptSw,
PuschUsePucchRbSwitch, PuschDtxSchOptSwitch,
ULFSSAlgoSwitch, PrachRbReuseSwitch, SrSchDataAdptSw,
UlFssUserThdStSwitch, HighOrderVMIMOSwitch,
VMIMOReduceMCSRiseRBSwitch, VoLTEUeVmimoSwitch
MML Default Value: None
Recommended Value: SpsSchSwitch:Off, SinrAdjustSwitch:On,
PreAllocationSwitch:On, UlVmimoSwitch:Off, TtiBundlingSwitch:Off,
ImIcSwitch:Off, SmartPreAllocationSwitch:On, PuschDtxSwitch:On
in LTE FDD, UlIblerAdjustSwitch:Off, UlEnhancedFssSwitch:On,
UlEnhancedSrSchSwitch:On, SchedulerCtrlPowerSwitch:Off,
UlIicsAlgoSwitch:Off, UlMinGbrSwitch:Off, UlMbrCtrlSwitch:Off,
MbrUlSchSwitch:Off, UeAmbrUlSchSwitch:Off,
UlEnhancedDopplerSwitch:Off, UlRaUserSchOptSw:Off,
UlLast2RetransSchOptSwitch:On, UlInterfFssSwitch:Off,
UlSmallRBSpectralEfficiencyOptSw:Off,
PuschUsePucchRbSwitch:Off, PuschDtxSchOptSwitch:Off,
ULFSSAlgoSwitch:On, PrachRbReuseSwitch:Off,
SrSchDataAdptSw:On, UlFssUserThdStSwitch:Off,
HighOrderVMIMOSwitch:Off,
VMIMOReduceMCSRiseRBSwitch:Off, VoLTEUeVmimoSwitch:Off
Parameter Relationship:
-Configuration constraints:
PsicSwitch in the CellAlgoSwitch MO is set to On only if
UlVmimoSwitch under UlSchSwitch in a CellAlgoSwitch MO is set to
On.
OutOfBandRelaySwitch under the RelaySwitch parameter in the
CellAlgoSwitch MO cannot be turned on when TtiBundlingSwitch
under the UlSchSwitch parameter is turned on.
OutOfBandRelaySwitch under the RelaySwitch parameter in the
CellAlgoSwitch MO cannot be turned on when UlIicsAlgoSwitch
under the UlSchSwitch parameter is turned on.
If SuperCombCellSwitch of SfnAlgoSwitch in the CellAlgoSwitch MO
is set to on, SpsSchSwitch of UlSchSwitch in the CellAlgoSwitch MO
must be deselected.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: SmartPreAllocationSwitch:
When DRX is disabled, selecting this option increases the uplink
delay and decreases the uplink interference and UE power
consumption; deselecting this option results in the opposite effects.
When DRX is enabled, selecting this option decreases the uplink
delay and increases the downlink throughput, but also increases the
uplink interference and UE power consumption; deselecting this
option results in the opposite effects. The degree of impacts on
network performance depends on the SmartPreAllocationDuration
parameter value.
UlEnhancedFssSwitch: If this option is selected, the uplink
modulation and coding scheme (MCS) order and uplink throughput
increase. If this option is deselected, the uplink MCS order and
uplink throughput decrease. UlIicsAlgoSwitch: If this option is
selected in scenarios where the cell is interference-limited in the
uplink and heavily loaded, parameters related to IICS algorithms in a
cell can be checked by adding the local cell ID, which does not
affect network performance.
UlEnhancedSrSchSwitch: If uplink traffic is light in the cell and DRX
is enabled, selecting this option decreases the uplink IBLER and
retransmission BLER, increases RB utilization, reduces interference
on neighboring cells, increases cell throughput, but prolongs ping
latency. If uplink traffic is heavy in the cell or DRX is disabled,
selecting this option has no impact on network performance.
SchedulerCtrlPowerSwitch: If this option is selected in a network of
a medium or light load, the average uplink transmit power increases
by 0.2 dBm to 0.5 dBm, the uplink MCS increases, and uplink
throughput increases for UEs at far or medium distances from cell
center. Uplink throughput for UEs near the cell center does not
change. If this option is deselected in a network of a heavy load (for
example, when the RB usage is greater than 70%), uplink
interference slightly increases and the throughput of UEs affected by
uplink interference slightly decreases.
UlMinGbrSwitch: If this option is deselected, the uplink data rate of
non-GBR services cannot be ensured. There is a possibility that no
resource can be allocated to non-GBR services, and service drop
occurs. If this option is selected, the minimum GBRs of non-GBR
services are configured based on QoS class identifiers (QCIs), and
the uplink data rates of non-GBR services are ensured, but the cell
capacity may decrease as the eNodeB attempts to ensure the
minimum GBR of cell edge users (CEUs).
UlMbrCtrlSwitch: If this option is selected and the MBR is greater
than the GBR and a GBR bearer is set up for a UE, the eNodeB
allocates more RBs to uplink GBR services, and the uplink traffic
volume on the GBR bearer increases when conditions for required
uplink services are met. If the MBR is equal to the GBR, selecting
this option has no impacts on the network performance. If this option
is deselected, the eNodeB performs scheduling based only on the
GBR for uplink GBR bearers and network performance is not
affected.
MbrDlSchSwitch/UeAmbrDlSchSwitch: If this option is selected,
throughput of UEs with greater MBR/AMBR increases, and
throughput of UEs with smaller MBR/AMBR decreases. In addition,
system throughput may also be affected by the differences between
MBRs/AMBRs of UEs and the distribution of UEs in the cell. If this
option is deselected, the throughput differences between UEs with
different MBRs/AMBRs decrease. In addition, system throughput is
not affected by the differences between MBRs/AMBRs of UEs or the
distribution of UEs in the cell.
UlEnhancedDopplerSwitch: If this option is selected, uplink
frequency selective scheduling performance of low-mobility UEs
increases. The cell coverage and data rate of CEUs increase, and
the PRB usage decreases.
UlRaUserSchOptSw: Selecting this option increases the RRC
connection setup success rate and decreases the average delay for
RRC connection setup. However, performance counters related to
uplink throughput may decrease because uplink data transmission is
interrupted in the following scenarios: (1) Many UEs initiate random
access procedures; (2) Congestion occurs during signaling
scheduling. Deselecting this option has no impact on network
performance.
UlLast2RetransSchOptSwitch: Optimization on the scheduling policy
for the last two retransmissions is enabled only if this option is
selected.
If this option is deselected, the default scheduling policy is used and
the network performance is not affected.
If this option is selected, the scheduling policy for the last two
retransmissions is optimized. As a result, the RBLER in the uplink
decreases in most scenarios. However, cell throughput in the
downlink decreases when the last two retransmissions consume
excessive PDCCH resources. In addition, cell throughput in the
uplink decreases and the delay for scheduling UEs in and near the
cell center increases when excessive PDCCH resources or RBs are
consumed by too many UEs scheduled in the last two
retransmissions.
UlInterfFssSwitch: Selecting this option decreases the uplink
RBLER.
Deselecting this option has no impact on network performance.
PuschUsePucchRbSwitch: The number of activated L2 UEs in each
TTI is used to determine whether the cell serves a single UE. If the
number of activated L2 UEs is 1, the cell serves a single UE. In this
case, if this option is selected, PUCCH RBs can be occupied by the
PUSCH, the peak rate of UEs in the cell center increases, and
interference to the PUCCH may increase. If the number of activated
L2 UEs is more than 1, the switch setting does not take effect and
the network performance is not affected.
UlIblerAdjustSwitch: If this option is selected, uplink throughput in
benchmark drive tests increases. In live networks, if large-packet
services need to be transmitted in the uplink, selecting this option
increases uplink throughput, increases throughput of CEUs, and
slightly increases the residual block error rate (RBLER). If no large-
packet services need to be transmitted in the uplink in live networks,
selecting this option has no impact on KPIs.
PuschDtxSchOptSwitch: If this option is selected, uplink scheduling
resources can be saved and the cell throughput increases.
Deselecting this option has no impact on network performance.
PrachRbReuseSwitch: If this option is selected, the uplink data rate
increases but the RRC connection setup success rate may
decrease. If this option is deselected, the RRC connection setup
success rate is not affected but the uplink data rate decreases.
ULFSSAlgoswitch: If this option is selected, uplink frequency-
selective scheduling is enabled when the network load is light, which
improves the uplink MCS index and increases the throughput. Uplink
frequency-selective scheduling is disabled when the network load is
heavy, which reduces the number of resource fragments and
increases the throughput. If this option is deselected, uplink
frequency-selective scheduling is disabled. The uplink MCS index
and throughput decrease when the network load is light.
SrSchDataAdptSw: If this option is deselected, data volume
adaption in SR scheduling is disabled, and ping latency may
increase. If this option is selected (the default setting), data volume
adaption in SR scheduling is enabled, and network performance is
not affected.
UlFssUserThdStSwitch: If this option is selected, the proportion of
UEs that are selected for frequency selective scheduling increases,
uplink user data rate increases, and uplink RBLER decreased. If this
option is deselected, network performance is not affected.
HighOrderVMIMOSwitch: If this option is selected, a maximum of
four UEs can use the same time-frequency resource to transmit
data, which increases the overall uplink throughput of a cell. If this
option is deselected, four UEs cannot use the same time-frequency
resource to transmit data, which does not increase the overall uplink
throughput of a cell.
VMIMOReduceMCSRiseRBSwitch: If this option is selected, VMIMO
pairing is performed for UEs whose MCS index is reduced to
increase the number of RBs, which increases the uplink throughput
of a cell. If this option is deselected, VMIMO pairing is not performed
for UEs whose MCS index is reduced to increase the number of
RBs, which decreases the uplink throughput of a cell.
VoLTEUeVmimoSwitch: If this option is selected, VMIMO pairing is
performed for VoLTE UEs, which increases the number of VoLTE
UEs supported in a cell. If this option is deselected, VMIMO pairing
is not performed for VoLTE UEs, which decreases the number of
VoLTE UEs supported in a cell.
Applicable Mode: L

RanShareModeS RAN Meaning: Indicates whether to enable or disable RAN sharing for
witch Sharing admission and scheduling. If this switch is turned on, operators
Mode share data channel resources according to the specified
Switch percentages.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: Yes
Impact on Radio Network Performance: None
Applicable Mode: L

FreqPriorityHoSw Based on Meaning: Indicates whether to enable frequency-priority-based inter-


itch Frequency frequency handover algorithms. This parameter includes the
Priority HO following options: FreqPriorIFHOSwitch: Frequency-priority-based
Switch inter-frequency handover is applicable when the two E-UTRAN
frequencies provide the same coverage and one frequency is
preferred for carrying services. If this option is selected, the
frequency-priority-based inter-frequency handover will be triggered
even when the serving cell provides a good signal quality. If this
option is deselected, the frequency-priority-based inter-frequency
handover is disabled, and the inter-frequency handover can be
triggered only when other conditions are met.
FreqPriorIFBlindHOSwitch: If this option is selected, frequency-
priority-based inter-frequency handovers are performed in a blind
manner. If this option is deselected, frequency-priority-based inter-
frequency handovers are performed based on measurements. This
option takes effect only when the FreqPriorIFHOSwitch option is
selected. MlbBasedFreqPriHoSwitch: Indicates whether to enable
frequency-priority-based inter-frequency handovers when MLB is
triggered. If this option is selected, the eNodeB stops performing
frequency-priority-based inter-frequency handovers on UEs that
newly access the cell with MLB enabled. If this option is deselected,
the eNodeB continues performing frequency-priority-based inter-
frequency handovers on UEs that newly access the cell with MLB
enabled. This option takes effect only when the
FreqPriorIFHOSwitch option is selected. A2BasedFreqPriHoSwitch:
Indicates whether measurements for frequency-priority-based
handovers are triggered based on event A2. If this option is
selected, new UEs (including UEs that newly access the cell,
handed over to the cell, and reestablish RRC connections in the cell)
that meet conditions of triggering event A2 perform measurements
on high-priority frequencies. If this option is deselected, new UEs
that meet conditions of triggering event A1 perform measurements
on high-priority frequencies or perform blind handovers. This option
takes effect only when the FreqPriorIFHOSwitch option is selected.
LoadTriggerFreqPriHoSwitch: Indicates whether to trigger
frequency-priority-based handovers based on the load of the target
cell. If this option is selected, the serving cell obtains loads in
candidate neighboring cells for handovers. If there is a candidate
neighboring cell that has not triggered UE-number-based MLB, the
candidate neighboring cell can be selected as the target cell for
frequency-priority-based handovers from the serving cell. Only a
candidate neighboring cell that has not triggered UE-number-based
MLB can be selected as the target cell in frequency-priority-based
handovers. If all candidate neighboring cells have triggered UE-
number-based MLB, frequency-priority-based handovers cannot be
triggered for UEs in the serving cell. If the option is deselected, the
serving cell does not consider loads of candidate neighboring cells
when determining whether to trigger frequency-priority-based
handovers.
GUI Value Range: FreqPriorIFHOSwitch(FreqPriorIFHOSwitch),
FreqPriorIFBlindHOSwitch(FreqPriorIFBlindHOSwitch),
MlbBasedFreqPriHoSwitch(MlbBasedFreqPriHoSwitch),
A2BasedFreqPriHoSwitch(A2BasedFreqPriHoSwitch),
LoadTriggerFreqPriHoSwitch(LoadTriggerFreqPriHoSwitch)
Unit: None
Actual Value Range: FreqPriorIFHOSwitch,
FreqPriorIFBlindHOSwitch, MlbBasedFreqPriHoSwitch,
A2BasedFreqPriHoSwitch, LoadTriggerFreqPriHoSwitch
MML Default Value: None
Recommended Value: FreqPriorIFHOSwitch:Off,
FreqPriorIFBlindHOSwitch:On, MlbBasedFreqPriHoSwitch:Off,
A2BasedFreqPriHoSwitch:Off, LoadTriggerFreqPriHoSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: FreqPriorIFHOSwitch: If this
option is selected, UEs are handed over to other cells based on
frequency-priority-based inter-frequency handovers. The number of
handovers increases, and the service rate increases.
FreqPriorIFBlindHOSwitch: If this option is selected, the number of
gap-assisted measurements decreases. To ensure the handover
success rate, strictly set the trigger condition of the frequency-
priority-based inter-frequency handovers (that is, setting the
threshold related to event A1 to a large value).
MlbBasedFreqPriHoSwitch: If this option is selected, MLB is
triggered, and the target frequency for frequency-priority-based
handovers is the frequency used to offload traffic of the source cell
during MLB, then the loads in the network can be centrally managed
based on the MLB algorithms when the network is heavily loaded,
thereby improving resource utilization rate. If this option is
deselected, the target frequency selected based on target frequency
configuration in a frequency-priority-based inter-frequency handover
is different from the target frequency selected for load balancing,
thereby improving resource utilization rate.
A2BasedFreqPriHoSwitch: Sepecting this option applies when cells
working at high-priority frequencies and cells working at low-priority
frequencies are served by different eNodeBs. Deselecting this
option applies when cells working at high-priority frequencies and
cells working at low-priority frequencies are served by the same
eNodeB.
LoadTriggerFreqPriHoSwitch: If this option is selected and the target
cell for frequency-priority-based handovers is enabled with MLB, the
serving cell determines whether to trigger frequency-priority-based
handovers to the target cell based on the fact that whether UE-
number-based MLB has been triggered in the target cell. In this way,
the number of invalid GAP-assisted measurements decreases,
handover preparation failures can be avoided, average user
throughput increases, and signaling overheads related to load
exchange over the X2 interfaces increase. Deselecting this option
will generate a large number of invalid GAP-assisted measurements
and a large number of handover preparation failures, but does not
increase signaling overheads related to load exchange over the X2
interfaces.
Applicable Mode: L

MuBfAlgoSwitch MUBF Meaning: Indicates whether to enable or disable multi-user


Algorithm beamforming (MUBF). This parameter is valid only if the BfSwitch
Switch option is selected under the BfAlgoSwitch parameter. This
parameter applies only to LTE TDD networks.
MuBfSwitch: If this option is selected, multi-user pairing in the
downlink is enabled for a cell. If this option is deselected, multi-user
pairing is disabled.
TM9MuBfSwitch: If the TM9MuBfSwitch and MuBfSwitch options
under the MuBfAlgoSwitch parameter and the TM9Switch option
under the EnhMIMOSwitch parameter are selected, downlink TM9
multi-user pairing in closed-loop mode is enabled for a cell. If this
option is deselected, TM9 multi-user pairing in closed-loop mode is
disabled.
HighOrderMubfSwitch: If this option and the MuBfSwitch option are
selected, high-order multi-user pairing is enabled in the downlink for
a cell. If this option is selected but the MuBfSwitch option is
deselected, or if this option is deselected, high-order multi-user
pairing is disabled.
MubfResAdjSwitch: If this option and the MuBfSwitch option are
selected, MU beamforming resource adjustment is enabled in the
downlink. If this option is selected but the MuBfSwitch option is
deselected, or if this option is deselected, MU beamforming
resource adjustment is disabled in the downlink.
GUI Value Range: MuBfSwitch(MuBfSwitch),
TM9MuBfSwitch(TM9MuBfSwitch),
HighOrderMubfSwitch(HighOrderMubfSwitch),
MubfResAdjSwitch(MubfResAdjSwitch)
Unit: None
Actual Value Range: MuBfSwitch, TM9MuBfSwitch,
HighOrderMubfSwitch, MubfResAdjSwitch
MML Default Value: None
Recommended Value: MuBfSwitch:Off, TM9MuBfSwitch:Off,
HighOrderMubfSwitch:Off, MubfResAdjSwitch:Off
Parameter Relationship:
-Configuration constraints:
In the CellAlgoSwitch MO, the TM9MuBfSwitch check box can be
selected under the MuBfAlgoSwitch parameter only if the
MuBfSwitch check box is selected under the MuBfAlgoSwitch
parameter or the SfnCbfSwitch check box is selected under the
SfnAlgoSwitch parameter.
In the CellAlgoSwitch MO, the MubfResAdjSwitch check box can be
selected under the MuBfAlgoSwitch parameter only if both the
following conditions are met:
The MuBfSwitch check box is selected under the MuBfAlgoSwitch
parameter or the SfnCbfSwitch check box is selected under the
SfnAlgoSwitch parameter.
-Others:
In the CellAlgoSwitch, SsrdAlgoSwitch and MuBfAlgoSwitch cannot
be set to On simultaneously.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: The TM9Switch option,
HighOrderMubfSwitch option, and the MubfResAdjSwitch option can
be selected only when the MuBfSwitch option is selected.
If the MuBfSwitch option is selected and the HighOrderMubfSwitch
option is deselected, non-high-order multi-user pairing is enabled in
the downlink. The pairing can be performed between a maximum of
two layers, which increases the average downlink throughput in
heavy load scenarios.
If the MuBfSwitch option and the HighOrderMubfSwitch option are
selected, high-order multi-user pairing is enabled in the downlink.
The pairing can be performed between a maximum of four layers,
which further increases the average downlink throughput in heavy
load scenarios.
It is recommended that the MubfResAdjSwitch option be selected
when the MuBfSwitch option is selected. If the MubfResAdjSwitch
option is selected, MU beamforming resource adjustment is
enabled. MU beamforming resource adjustment helps reduce the
interference of the local cell to neighboring cells or the number of
residual small packets generated when two UEs are paired for MU
beamforming in light-load scenarios.
If the TM9MuBfSwitch option is selected, closed-loop TM9 UEs can
be paired to increase the average downlink throughput in a heavily
loaded cell. Do not select this option if a cell is lightly loaded or
pairing of closed-loop TM9 UEs is not expected.
Applicable Mode: L

DistBasedHoSwit Distance- Meaning: Indicates the switch used to enable or disable distance-
ch based based handovers. If this switch is turned on, distance-based
Handover handovers are allowed. If this switch is turned off, distance-based
Switch handovers are prohibited.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this switch is turned on,
distance-based handovers are allowed and the handover success
rate increases. If this switch is turned off, distance-based handovers
are prohibited and the handover success rate decreases.
Applicable Mode: L
AcBarAlgoSwitch AcBar Meaning: Indicates the switch for the access barring algorithm. If this
algorithms parameter is set to ACBAR_SWITCH_DYNAMIC, intelligent access
switch barring is enabled. In this situation, the access probability factors for
mobile-originated data and mobile-originated signaling are
dynamically adjusted based on the cell load. If this parameter is set
to ACBAR_SWITCH_STATIC, static access barring is enabled. In
this situation, the access probability factors and average access
barring durations are configured in the access barring information. If
this parameter is set to ACBAR_SWITCH_DISABLE, access barring
is disabled.
GUI Value Range: ACBAR_SWITCH_DYNAMIC(dynamic
configuration), ACBAR_SWITCH_STATIC(static configuration),
ACBAR_SWITCH_DISABLE(Disable)
Unit: None
Actual Value Range: ACBAR_SWITCH_DYNAMIC,
ACBAR_SWITCH_STATIC, ACBAR_SWITCH_DISABLE
MML Default Value: None
Recommended Value: ACBAR_SWITCH_STATIC(static
configuration)
Parameter Relationship:
-Configuration constraints:
In the CellAlgoSwitch MO, if AcBarAlgoSwitch is set to
ACBAR_SWITCH_DYNAMIC, either the DYNAMIC_FOR_MO or
DYNAMIC_FOR_SSAC option of AcBarAlgoforDynSwitch must be
selected.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
ACBAR_SWITCH_DYNAMIC, the access probability factor for
mobile-originated calls and mobile-originated signaling are
dynamically adjusted based on the current cell load. In this way, the
probabilities of UEs accessing the cell can be controlled to relieve
the cell load.
Applicable Mode: L

SfnUlSchSwitch SFN UL Meaning: Indicates the SFN uplink scheduling mode. The uplink
Scheduling scheduling modes include the joint scheduling mode, and the auto-
Switch selection mode between joint scheduling and independent
scheduling.
GUI Value Range: ADAPTIVE(Adaptive scheduling), JOINT(Joint
scheduling)
Unit: None
Actual Value Range: ADAPTIVE, JOINT
MML Default Value: None
Recommended Value: FDD: SFN: JOINT(Joint scheduling); TDD:
Indoor SFN: JOINT(Joint scheduling), Outdoor SFN:
ADAPTIVE(Adaptive scheduling), Cell combination: JOINT(Joint
scheduling).
Parameter Relationship:
-Configuration constraints:
In the CellAlgoSwitch MO, if SfnUlSchSwitch is set to ADAPTIVE or
SfnDlSchSwitch is set to ADAPTIVE, SuperCombCellSwitch of
SfnAlgoSwitch must be deselected.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If the cell load is high,
adaptive shceduling between joint scheduling and independent
scheduling is used to improve the total throughput of the cell.
Applicable Mode: L

SfnDlSchSwitch SFN DL Meaning: Indicates the SFN downlink scheduling mode. The
Scheduling downlink scheduling modes include the joint scheduling mode, and
Switch the auto-selection mode between joint scheduling and independent
scheduling.
GUI Value Range: ADAPTIVE(Adaptive scheduling), JOINT(Joint
scheduling)
Unit: None
Actual Value Range: ADAPTIVE, JOINT
MML Default Value: None
Recommended Value: FDD: SFN: JOINT(Joint scheduling); TDD:
Indoor SFN: JOINT(Joint scheduling), Outdoor SFN:
ADAPTIVE(Adaptive scheduling), Cell combination: JOINT(Joint
scheduling).
Parameter Relationship:
-Configuration constraints:
In a CellAlgoSwitch, if SfnDlSchSwitch is not set to ADAPTIVE, then
the SfnAlgoSwitch in CellAlgoSwitch could not turn on
SfnPdcchSdmaSwitch.
In the CellAlgoSwitch MO, if SfnUlSchSwitch is set to ADAPTIVE or
SfnDlSchSwitch is set to ADAPTIVE, SuperCombCellSwitch of
SfnAlgoSwitch must be deselected.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If the cell load is high,
adaptive shceduling between joint scheduling and independent
scheduling is used to improve the total throughput of the cell.
Applicable Mode: L

IrcSwitch IRC Switch Meaning: Indicates whether to apply MRC/IRC adaptation to the
PUCCH/PRACH in a cell.
PucchIrcSwitch: If this option is selected, MRC/IRC adaptation
applies to the PUCCH. If this option is deselected, MRC applies to
the PUCCH. The LBBPc does not support PUCCH MRC or IRC.
PrachIrcSwitch:
When the eNodeB is equipped with LBBPc boards and uses one or
two RX antennas, PrachIrcSwitch of the IrcSwitch parameter and
the PrachIntrfRejSwitch parameter together control the interference
rejection technique applied to the PRACH. If the PrachIntrfRejSwitch
parameter is set to off, interference rejection is not applied to the
PRACH. When the PrachIntrfRejSwitch parameter is set to on,
PrachIrcSwitch of the IrcSwitch parameter takes effect. 1. If the
PrachIrcSwitch option is deselected, MRC is applied to the PRACH.
2. If the PrachIrcSwitch option is selected, MRC/IRC adaptation is
applied to the PRACH.
If the eNodeB is equipped with LBBPc boards and uses more than
two RX antennas, interference rejection is not supported.
If the eNodeB is equipped with LBBPd, UBBPd, or UBBPe boards,
the PrachIntrfRejSwitch parameter setting does not take effect. 1. If
the PrachIrcSwitch option is deselected, MRC is applied to the
PRACH. 2. If the PrachIrcSwitch option is selected, MRC/IRC
adaptation is applied to the PRACH.
GUI Value Range: PucchIrcSwitch, PrachIrcSwitch
Unit: None
Actual Value Range: PucchIrcSwitch, PrachIrcSwitch
MML Default Value: None
Recommended Value: PucchIrcSwitch:Off, PrachIrcSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If the PrachIrcSwitch option
of this parameter is selected, the PRACH false alarm probability
decreases, the success rates of access, handovers,
resynchronization, and RRC connection reestablishments through
the RACH increase. However, the probability that UEs in weak
coverage areas attempt to access the network increases, thereby
decreasing the RRC connection setup success rate.
Applicable Mode: L

DynDrxSwitch Dynamic Meaning: Indicates whether to enable dynamic discontinuous


DRX reception (DRX) or smart DRX. Unlink dynamic DRX and smart DRX
switch apply only to LTE TDD cells and requires the mobility speed of UEs
to be reported. DynDrxSwitch: If this switch is on, dynamic DRX
applies to newly admitted UEs to reduce signaling overheads or
decrease UE power consumption. If this switch is off, dynamic DRX
does not apply to newly admitted UEs. Dynamic DRX applies to
carrier aggregation (CA) UEs only when this switch is on in both the
primary serving cell (PCell) and secondary serving cell (SCell).
SmartDrxSwitch: If this switch is on, smart DRX applies to newly
admitted UEs that support mobility speed reporting. The eNodeB
dynamically sets DRX-related parameters based on UE mobility
speeds. If this switch is off, smart DRX does not apply to newly
admitted UEs. Smart DRX applies to CA UEs only when this switch
is on in both the PCell and SCell. If DynDrxSwitch is on, setting the
DrxAlgSwitch parameter to ON cannot ensure that DRX is enabled
on synchronized UEs.
GUI Value Range: DynDrxSwitch(DynDrxSwitch),
SmartDrxSwitch(SmartDrxSwitch)
Unit: None
Actual Value Range: DynDrxSwitch, SmartDrxSwitch
MML Default Value: None
Recommended Value: DynDrxSwitch:Off, SmartDrxSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: When this switch is on, the
dynamic DRX feature reduces the signaling overhead and
decreases UE power consumption, achieving a trade-off between
the signaling overhead and UE power consumption.
Applicable Mode: L

HighMobiTrigIdle High Meaning: Indicates whether to enable the high-mobility-triggered-idle


ModeSwitch Mobility switch. When this parameter is set to ENABLE, UEs in high mobility
Triggered are released and enter the idle mode, and therefore the signaling
Idle Mode impact on the network caused by frequent handovers are reduced.
Switch When this parameter is set to DISABLED, UEs in high mobility are
not released.
GUI Value Range: DISABLE(Disable), ENABLE(Enable)
Unit: None
Actual Value Range: DISABLE, ENABLE
MML Default Value: None
Recommended Value: DISABLE(Disable)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

AvoidInterfSwitch Interferenc Meaning: Indicates whether to enable interference avoidance in the


e cell.
avoidance If the AvoidGeranInterfSwitch option is selected, GL Bufferzone
switch optimization is enabled.
Before selecting this option, pay attention to the following:
1. The cell bandwidth must be expanded to the immediate higher
level of standard bandwidths. The bandwidth of a 15 MHz cell must
be changed to 20 MHz.
2. It is recommended that this option be deselected if the bandwidth
of a cell is 1.4 MHz, 3 MHz, 5 MHz, or 10 MHz.
3. To avoid interference to the PUCCH from intra-frequency GERAN
cells, select the PucchFlexCfgSwitch (PucchFlexCfgSwitch) option
under the PucchAlgoSwitch parameter.
When the TddAvoidUpPTSInterfSwitch option is selected, the
UpPTS interference detection and avoidance function is enabled for
LTE TDD cells.
When the AvoidPrachInterfSwitch option is selected, the PRACH
interference avoidance function is enabled for LTE TDD cells.
If the AvoidUtranInterfSwitch option is selected, UL Bufferzone
optimization is enabled. UL Bufferzone optimization applies only to
LTE FDD cells.
If the AvoidSpurEmissInterfSwitch option is selected, avoidance of
spurious interference is enabled. This option applies only to LTE
FDD.
When the IntraBandInterfMonitorSwitch option is selected, the in-
band interference monitoring function is enabled for the cell. When
the IntraBandInterfMonitorSwitch option is deselected, the in-band
interference monitoring function is disabled for the cell. This option
does not apply to cells served by LBBPc boards. This option applies
only to LTE TDD cells.
The AvoidCDMAInterfSwitch option indicates whether to enable
CDMA and LTE zero bufferzone. It is recommended that this feature
be enabled at the bufferzone of CDMA and LTE refarming. Because
of frequency band differences between RATs, CDMA and LTE zero
bufferzone is mutually exclusive with GL DSS, GL zero bufferzone,
and UL bufferzone optimization. You are advised not to enable
CDMA and LTE zero bufferzone with GL DSS, GL zero bufferzone,
or UL bufferzone optimization. CDMA and LTE zero bufferzone
applies only to LTE FDD cells.
If the UlInterfSuppressionSwitch option is selected, uplink power
control parameters are adjusted based on interference, and
conservative scheduling is performed for access signaling. This
option applies only to LTE TDD cells.
GUI Value Range: AvoidGeranInterfSwitch(AvoidGeranInterfSwitch),
TddAvoidUpPTSInterfSwitch(TddAvoidUpPTSInterfSwitch),
AvoidPrachInterfSwitch(AvoidPrachInterfSwitch),
AvoidUtranInterfSwitch(AvoidUtranInterfSwitch),
IntraBandInterfMonitorSwitch(IntraBandInterfMonitorSwitch),
AvoidSpurEmissInterfSwitch(AvoidSpurEmissInterfSwitch),
UlInterfSuppressionSwitch(UlInterfSuppressionSwitch),
AvoidCDMAInterfSwitch(AvoidCDMAInterfSwitch)
Unit: None
Actual Value Range: AvoidGeranInterfSwitch,
TddAvoidUpPTSInterfSwitch, AvoidPrachInterfSwitch,
AvoidUtranInterfSwitch, IntraBandInterfMonitorSwitch,
AvoidSpurEmissInterfSwitch, UlInterfSuppressionSwitch,
AvoidCDMAInterfSwitch
MML Default Value: None
Recommended Value: AvoidGeranInterfSwitch:Off
TddAvoidUpPTSInterfSwitch:Off
AvoidPrachInterfSwitch:Off
AvoidUtranInterfSwitch:Off
IntraBandInterfMonitorSwitch:Off
AvoidSpurEmissInterfSwitch:Off
UlInterfSuppressionSwitch:Off
AvoidCDMAInterfSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: 1. AvoidGeranInterfSwitch:
If this option is deselected, the LTE frequency spectrum does not
overlap with the GSM frequency spectrum and accordingly network
KPIs are not affected. If this option is selected, the available
bandwidth of the E-UTRAN cell increases. In this situation, more
RBs can be dynamically used to improve the average cell
throughput based on whether UEs can resist GERAN interference.
However, because the LTE frequency spectrum may overlap with
the GSM frequency spectrum, the access success rate and
handover success rate may drop, and the service drop rate may
increases.
2. TddAvoidUpPTSInterfSwitch: If this option is deselected, downlink
beamforming does not take effect for CEUs when UpPTS
interference is severe. If this option is selected, the eNodeB adjusts
the SRSs originally transmitted on the UpPTS to common uplink
subframes after severe UpPTS interference occurs, and downlink
beamforming becomes effective for CEUs. After SRSs are adjusted
to common uplink subframes, the last symbol in each uplink
subframe cannot be used to transmit the PUSCH. Only 10 instead of
11 symbols are used to transfer data in each uplink subframe after
SRSs are adjusted to the uplink subframe. If the number of RBs
used by a UE and the MCS index remain unchanged, the uplink
throughput of the UE decreases by 9% under the worst conditions.
3. AvoidPrachInterfSwitchL: If this option is deselected, the PRACH
modulation quality is poor if severe PRACH interference occurs, and
access to the cell becomes difficult for UEs. If this option is selected,
the eNodeB moves the PRACH to a frequency domain position with
weak interference if severe PRACH interference occurs, improving
the PRACH modulation quality and access experience.
4. AvoidUtranInterfSwitch: If this option is deselected, LTE uplink
scheduling may cause strong interference to UMTS intra-frequency
neighboring cells in the uplink. If this option is selected, the eNodeB
restricts uplink RB scheduling to reduce interference to UMTS intra-
frequency neighboring cells, which reduces LTE uplink capacity.
5. AvoidCDMAInterfSwitch: AvoidCDMAInterfSwitch: If this option is
selected, the eNodeB restricts uplink and downlink RB scheduling to
alleviate interference to CDMA intra-frequency neighboring cells,
reducing LTE uplink and downlink capacity. If this option is
deselected, LTE uplink and downlink scheduling may cause strong
interference to CDMA intra-frequency neighboring cells in the uplink
and downlink.
6. UlInterfSuppressionSwitch: If this option is selected, KPIs such as
the call drop rate and the handover success rate are optimized when
uplink interference exceeds the value of the UlInterfsuppressionThd
parameter in the UlInterfSuppressCfg MO.
7. AvoidCDMAInterfSwitch: If this option is selected, the eNodeB
restricts uplink and downlink RB scheduling to alleviate interference
to CDMA intra-frequency neighboring cells. However, LTE uplink
capacity and downlink capacity are reduced. If this option is
deselected, LTE uplink and downlink scheduling may cause strong
interference to CDMA intra-frequency neighboring cells in the uplink
and downlink.
8. TddAvoidUpPTSInterfSwitch: Selecting this option may lead to
automatic cell reestablishment when interference occurs or required
signal quality recovers from deterioration due to interference.
Applicable Mode: L

GLPwrShare GL power Meaning: Indicates the switch used to enable or disable the GL
share dynamic power sharing algorithm. This algorithm can be used when
switch the GSM and LTE carriers share the same power amplifier. This
improves power usage and service quality of LTE UEs adopting
quadrature phase shift keying (QPSK) as their modulation scheme
in case that the GSM and LTE busy hours appear at different time
points or that the traffic is unbalanced. This parameter indicates the
switch for the GL dynamic power sharing feature at the LTE side.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship:
-Configuration constraints:
The DlCellCoverEnhanceAlgoSw option of
CellDlCoverEnhanceSwitch in the CellAlgoSwitch MO can be
selected only if GLPwrShare of the CellAlgoSwitch MO is set to
OFF.
In the CellAlgoSwitch MO, if the Virtual4T4RSwitch option of
EmimoSwitch is selected, GLPwrShare must be set to OFF.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

EicicSwitch Eicic Meaning: Indicates whether to disable the TDM eICIC algorithm or
Switch apply the static or dynamic mode to the eICIC algorithm. In a
heterogeneous network (HetNet), the eICIC function is used
together with the cell range expansion (CRE) function of the micro
base station to expand the coverage and increase the number of
users absorbed by the micro cell. To implement the eICIC function,
ensure that the value of this parameter must be set consistently for
macro and micro cells. Static mode applies only to TDD, and
dynamic mode applies only to FDD.
GUI Value Range: OFF(Off), STATIC(Static), DYNAMIC(Dynamic)
Unit: None
Actual Value Range: OFF, STATIC, DYNAMIC
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship:
-Configuration constraints:
EicicSwitch in the CellAlgoSwitch MO cannot be set to STATIC or
DYNAMIC when OutOfBandRelaySwitch under the RelaySwitch
parameter is turned on.
In the CellAlgoSwitch MO, if the AvoidCDMAInterfSwitch option of
AvoidInterfSwitch is selected, EicicSwitch must be set to OFF.
In the CellAlgoSwitch MO, if FeicicSwitch is set to ABS, EicicSwitch
must be set to DYNAMIC.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
OFF, TDM-based eICIC is disabled. The number of UEs absorbed
by the micro cell is small, user experience in the macro cell and that
in the micro cell are different. If this parameter is set to STATIC or
DYNAMIC, TDM-based eICIC is enabled. In this case, if a CRE is
not configured, throughput in both the macro cell and micro cells
decreases. If a proper CRE is configured, the number of UE
handovers from the macro cell to the micro cell increases, the
number of UEs absorbed by the micro cell increases, user
experience in the macro cell and that in the micro cell becomes
almost the same, and throughput of network edge UEs increases. In
a HetNet, dynamic eICIC provides higher cell edge user throughput
in a more stable manner than static eICIC.
Applicable Mode: L

PUSCHMaxRBP PUCCH Meaning: Indicates whether PUCCH resources are allocated based
UCCHAdjSwitch Resource on the uplink peak rate. If this parameter is set to ON(On), PUCCH
Switch resources are flexibly allocated based on the principle that the
Based on PUCCH is allocated fewer RBs when there are only a few UEs. This
UL Peak parameter applies only to LTE TDD cells.
Rate GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If there are only a few UEs,
setting this parameter to ON(On) improves the uplink throughput but
does not ensure the CAPS specifications of admitted UEs. As a
result, the RRC connection setup success rate may decrease in
large-CAPS scenarios.
Applicable Mode: L

DlCompSwitch Downlink Meaning: Indicates the switch used to enable or disable the DL
CoMP CoMP algorithm.
algorithms GUI Value Range: IntraDlCompSwitch(IntraDlCompSwitch),
switch InterDlCompDcsSwitch(InterDlCompDcsSwitch),
InterDlCompCbfSwitch(InterDlCompCbfSwitch)
Unit: None
Actual Value Range: IntraDlCompSwitch, InterDlCompDcsSwitch,
InterDlCompCbfSwitch
MML Default Value: None
Recommended Value: DlCompSwitch:Off
Parameter Relationship:
-Configuration constraints:
If the InterDlCompCbfSwitch check box under the DlCompSwitch
parameter is selected, the InterDlCompDcsSwitch check box cannot
be cleared.
If the FddTddInd parameter in the Cell MO is set to CELL_TDD, and
InterDlCompCbfSwitch or InterDlCompDcsSwitch under the
DlCompSwitch parameter in the CellAlgoSwitch MO is set to 1,
IntraDlCompSwitch under the DlCompSwitch parameter in the
CellAlgoSwitch MO must be set to 1.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If the IntraDlCompSwitch
check box is selected, the throughput of edge UEs in intra-eNodeB
cells increases but the average throughput of a cell may decrease.
If the InterDlCompDcsSwitch or InterDlCompCbfSwitch check box is
selected, the throughput of edge UEs in inter-eNodeB cells in a
cluster increases but the average throughput of a cell may decrease.
If DL CoMP is disabled, the throughput of CEUs decreases due to
co-channel interference.
Applicable Mode: L

PsicSwitch PSIC Meaning: Indicates whether to enable parallel soft interference


algorithm cancellation (PSIC). PSIC can be used only in FDD cells established
switch on UBBPd or LBBPd boards in 2x2 UL MU-MIMO scenarios. It does
not work in 2x4 or 4x4 UL MU-MIMO scenarios.
GUI Value Range:
MumimoPuschPsicSwitch(MumimoPuschPsicSwitch)
Unit: None
Actual Value Range: MumimoPuschPsicSwitch
MML Default Value: None
Recommended Value: MU-MIMO PUSCH PSIC:Off
Parameter Relationship:
-Configuration constraints:
PsicSwitch in the CellAlgoSwitch MO is set to On only if
UlVmimoSwitch under UlSchSwitch in a CellAlgoSwitch MO is set to
On.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If the
MumimoPuschPsicSwitch option is selected and there are UEs
paired for 2x2 MU MIMO, cell throughput increases. If the
MumimoPuschPsicSwitch option is deselected and there are UEs
paired for 2x2 MU MIMO, cell throughput decreases.
Applicable Mode: L

MlbHoMode Load Meaning: Indicates whether to enable or disable handovers


Balancing triggered by mobility load balancing (MLB), based on which the
Handover eNodeB determines handover policies.
Policy If the InterFreqMlbBlindHo check box under this parameter is
selected, the eNodeB performs a blind handover to an intra-RAT
inter-frequency neighboring cell for load balancing. Otherwise, the
eNodeB does not perform the blind handover. If the
InterFreqMlbRedirect check box under this parameter is selected,
the eNodeB performs a load-based redirection to an intra-RAT inter-
frequency neighboring cell. Otherwise, the eNodeB does not
perform the redirection.
If the InterRatMlbRedirect check box under this parameter is
selected, the eNodeB performs a redirection from an E-UTRAN cell
to a UTRAN or GERAN cell. Otherwise, the eNodeB does not
perform the redirection.
If the InterRatMlbBlindHo check box under this parameter is
selected, the eNodeB performs a blind handover from an E-UTRAN
cell to a UTRAN or GERAN cell for load balancing. Otherwise, the
eNodeB does not perform the blind handover.
GUI Value Range: InterFreqMlbBlindHo(InterFreqMlbBlindHo),
InterRatMlbBlindHo(InterRatMlbBlindHo),
InterFreqMlbRedirect(InterFreqMlbRedirect),
InterRatMlbRedirect(InterRatMlbRedirect)
Unit: None
Actual Value Range: InterFreqMlbBlindHo, InterRatMlbBlindHo,
InterFreqMlbRedirect, InterRatMlbRedirect
MML Default Value: None
Recommended Value: InterFreqMlbBlindHo:Off,
InterRatMlbBlindHo:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If the InterFreqMlbBlindHo
check box under this parameter is selected, inter-frequency blind
handovers are triggered for load sharing. This reduces the signaling
for GAP measurements but decreases the handover success rate
when blind-handover neighboring cells are not properly configured.
If the InterFreqMlbBlindHo check box under this parameter is
deselected, GAP-measurement-based inter-frequency handovers
are triggered for load sharing. This increases the signaling
overheads for GAP measurements but ensures the handover
success rate.
If the InterRatMlbBlindHo check box under this parameter is
selected, inter-RAT blind handovers are triggered for load sharing.
This reduces the signaling for GAP measurements but decreases
the handover success rate when blind-handover neighboring cells
are not properly configured. If the InterRatMlbBlindHo check box
under this parameter is deselected, GAP-measurement-based inter-
RAT handovers are triggered for load sharing. This increases the
signaling overheads for GAP measurements but ensures the
handover success rate. If the InterFreqMlbRedirect check box under
this parameter is selected, UEs that do not support inter-frequency
handovers can perform inter-frequency load sharing based on inter-
frequency redirections. If the InterFreqMlbRedirect check box under
this parameter is deselected, UEs that do not support inter-
frequency handovers cannot perform inter-frequency load sharing. If
the InterRatMlbRedirect check box under this parameter is selected,
UEs that do not support inter-RAT handovers can perform inter-RAT
load sharing based on inter-RAT redirections. If the
InterRatMlbRedirect check box under this parameter is deselected,
UEs that do not support inter-RAT handovers cannot perform inter-
RAT load sharing.
Applicable Mode: L

UplinkCompSwitc Uplink Meaning: Indicates whether to enable uplink coordinated multipoint


h Comp reception (UL CoMP) for a cell.
Switch If all of UlJointReceptionSwitch, UlJointReceptionPhaseIISwitch,
UlJointReception3CellSwitch, and UlHetnetJointReceptionSwitch of
this parameter are off, UL CoMP is disabled.
If UlJointReceptionSwitch is on, UlJointReceptionPhaseIISwitch is
off, UlJointReception3CellSwitch is off, and
UlHetnetJointReceptionSwitch is off, intra-site UL CoMP is enabled,
and each UE supports UL CoMP in at most two cells.
If UlJointReceptionSwitch is on, UlJointReceptionPhaseIISwitch is
on, UlJointReception3CellSwitch is off, and
UlHetnetJointReceptionSwitch is off, intra-BBU intra-site and inter-
site UL CoMP is enabled in cloud BB scenarios, and each UE
supports UL CoMP in at most two cells.
If UlJointReceptionSwitch is on, UlJointReceptionPhaseIISwitch is
on, UlJointReception3CellSwitch is on, and
UlHetnetJointReceptionSwitch is off, intra-BBU intra-site and inter-
site UL CoMP is enabled in cloud BB scenarios, and each UE
supports UL CoMP in at most three cells.
If UlJointReceptionSwitch is on, UlJointReceptionPhaseIISwitch is
on, UlJointReception3CellSwitch is off, and
UlHetnetJointReceptionSwitch is on, UL CoMP is enabled in HetNet
networking, intra-BBU intra-site and inter-site UL CoMP is enabled
in cloud BB scenarios, and each UE supports UL CoMP in at most
two cells.
If UlJointReceptionSwitch is on, UlJointReceptionPhaseIISwitch is
on, UlJointReception3CellSwitch is on, and
UlHetnetJointReceptionSwitch is on, UL CoMP is enabled in HetNet
networking, intra-BBU intra-site and inter-site UL CoMP is enabled
in cloud BB scenarios, and each UE supports UL CoMP in at most
three cells.
UlCompRollbackSwitch controls whether a CoMP UE is not selected
any more in UL CoMP and becomes a non-CoMP UE. If this switch
is on, the eNodeB detects signal qualities and interference changes
of the serving and coordinating cells of a CoMP UE in real time. If
the eNodeB detects that the interference from signals of UEs in the
coordinating cell cannot be mitigated using UL CoMP, the eNodeB
no longer selects the CoMP UE in UL CoMP, and the UE becomes a
non-CoMP UE. If this switch is off, the eNodeB always selects the
CoMP UE in UL CoMP, and the UE will never become a non-CoMP
UE. This parameter applies only to cells established on LBBPc
boards.
UlJointReception3CellSwitch controls whether three-cell UL CoMP
is enabled in the serving cell. The coordinating cell cannot know
whether itself is involved in three-cell UL CoMP. Assume
UlJointReception3CellSwitch is on for cell A and
UlJointReceptionSwitch is on for cell B. Then, three-cell UL CoMP is
enabled in cell A that acts as the serving cell while three-cell UL
CoMP does not need to be enabled in cell B that acts as a
coordinating cell.
UlHetnetCompManualNcellCfgSw indicates whether to enable
automatic or manual configuration of a macro cell's neighboring cell
list for measurement and a micro cell's homing macro cell. If this
switch is off, automatic configuration is enabled. If this switch is on,
manual configuration is enabled. One micro cell can belong to only
one macro cell.
UlHetnetCompOnUlRsrpSw: If this switch is off, A3-based
measurement is used for selecting coordinated cells in macro-micro
scenarios. If this switch is on, A3-based measurement is used in
macro-macro scenarios and UL-RSRP- or A3-baesd measurement
is used in macro-micro scenarios.; this switch takes effect only when
UlHetnetJointReceptionSwitch is on.
SimplePairedCompSw indicates whether to select UL CoMP UEs for
pairing for MU-MIMO. If all of UlJointReceptionSwitch,
UlVmimoSwitch of the UlSchSwitch parameter, and
SimplePairedCompSw are on, then UL CoMP UEs in 8R cells can
be selected for pairing. This switch applies only to TDD.
VoipPrioSw indicates whether to prioritize VoIP UEs. If this switch is
on, VoIP UEs have a higher priority than other UEs. If this switch is
off, VoIP UEs have a lower priority than other UEs. This switch
applies only to TDD.
UlCompInterBoardType2Sw indicates whether to enable inter-BBP
UL CoMP for type-2 UEs. If all of UlJointReceptionSwitch,
UlJointReceptionPhaseIISwitch, and UlCompInterBoardType2Sw
are on, then inter-BBP UL CoMP for type-2 UEs is enabled. This
parameter applies only to FDD.
GUI Value Range: UlJointReceptionSwitch(UlJointReceptionSwitch),
UlJointReceptionPhaseIISwitch(UlJointReceptionPhaseIISwitch),
UlCompRollbackSwitch(UlCompRollbackSwitch),
UlJointReception3CellSwitch(UlJointReception3CellSwitch),
UlHetnetJointReceptionSwitch(UlHetnetJointReceptionSwitch),
UlHetnetCompManualNcellCfgSw(UlHetnetCompManualNcellCfgSw
), UlHetnetCompOnUlRsrpSw(UlHetnetCompOnUlRsrpSw),
SimplePairedCompSw(SimplePairedCompSw),
VoipPrioSw(VoipPrioSw),
UlCompInterBoardType2Sw(UlCompInterBoardType2Sw)
Unit: None
Actual Value Range: UlJointReceptionSwitch,
UlJointReceptionPhaseIISwitch, UlCompRollbackSwitch,
UlJointReception3CellSwitch, UlHetnetJointReceptionSwitch,
UlHetnetCompManualNcellCfgSw, UlHetnetCompOnUlRsrpSw,
SimplePairedCompSw, VoipPrioSw, UlCompInterBoardType2Sw
MML Default Value: None
Recommended Value: UlJointReceptionSwitch:Off,
UlJointReceptionPhaseIISwitch:Off, UlCompRollbackSwitch:On,
UlJointReception3CellSwitch:Off, UlHetnetJointReceptionSwitch:Off,
UlHetnetCompManualNcellCfgSw:Off,
UlHetnetCompOnUlRsrpSw:Off, SimplePairedCompSw:Off,
VoipPrioSw:Off, UlCompInterBoardType2Sw:Off
Parameter Relationship:
-Configuration constraints:
In the CellAlgoSwitch MO, if UlJointReceptionPhaseIISwitch under
UplinkCompSwitch is turned on, UlJointReceptionSwitch under
UplinkCompSwitch must also be turned on.
In the CellAlgoSwitch MO, if UlJointReception3CellSwitch under
UplinkCompSwitch is turned on, UlJointReceptionSwitch under
UplinkCompSwitch must also be turned on.
In the CellAlgoSwitch, if UlCompInterBoardType2Sw under
UplinkCompSwitch is turned on, UlJointReceptionPhaseIISwitch
under UplinkCompSwitch must also be turned on.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: UlJointReceptionSwitch: If
this switch is on, the average uplink throughput of cells and cell
edge users (CEUs) increases. The improved uplink throughput of
CEUs indicates better uplink coverage.
UlJointReceptionPhaseIISwitch: If this switch is on, inter-BBP UL
CoMP is enabled, supporting more UL CoMP UEs and having better
performance than intra-BBP UL CoMP.
UlCompRollbackSwitch: Turning on this switch decreases the
service drop rate in strong interference scenarios but also decreases
uplink throughput. Turning off this switch results in the opposite
effects.
UlJointReception3CellSwitch: If this switch is off, 3-cell UL CoMP is
disabled. If this switch is on, 3-cell UL CoMP is enabled, with better
performance than 2-cell UL CoMP.
UlHetnetJointReceptionSwitch: If this switch is on, the uplink
throughput of macro and micro cells increase.
UlHetnetCompManualNcellCfgSw: The setting of this switch has no
impact on network performance.
UlHetnetCompOnUlRsrpSw: If this switch is on, the uplink
throughput of macro CEUs close to micro cells .
SimplePairedCompSw: If this switch is on, UL CoMP UEs can be
selected for pairing for MU-MIMO, UL CoMP performance improves,
and the UE pairing rate increases. If this switch is off, UL CoMP UEs
cannot be selected for pairing.
VoipPrioSw: If this switch is on, VoIP UEs take priority over other
UEs.
UlCompInterBoardType2Sw: If there are inter-BBP intra-frequency
neighboring cells, turning on this switch increases the average cell
throughput by mitigating interference between CEUs in these cells.
Turning off this switch results in the opposite effect.
Applicable Mode: L

AntCalibrationAlg Antenna Meaning: Indicates the switch used to enable or disable the antenna
oSwitch calibration calibration algorithm. This parameter applies only to TDD cells. If
algorithm this switch is on, the virtual antenna mapping (VAM) performance of
switch two groups of 4T cross-polarized antennas is improved. If this switch
is off, the antenna calibration algorithm is disabled. It is
recommended that this switch be on for two groups of 4T cross-
polarized antennas.
GUI Value Range:
CrossPolaCalibrationSwitch(CrossPolaCalibrationSwitch)
Unit: None
Actual Value Range: CrossPolaCalibrationSwitch
MML Default Value: None
Recommended Value: It is recommended that this switch be on for
two groups of 4T cross-polarized antennas.
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this switch is on, the
downlink cell throughput increases.
Applicable Mode: L

DynSpectrumSha Dynamic Meaning: Indicates whether to enable dynamic spectrum sharing in


reSwitch Spectrum the E-UTRAN cell, including GSM and LTE (GL) dynamic spectrum
Share sharing and GL zero bufferzone. This parameter applies only to LTE
Switch FDD.
GLDynSpectrumShareSwitch: The GSM and LTE Dynamic
Spectrum Sharing(LTE FDD) feature is enabled only when this
option is selected.
GLZeroBufferZoneSwitch: The GSM and LTE Zero Bufferzone
feature is enabled only when this option is selected.
Before the GLDynSpectrumShareSwitch or
GLZeroBufferZoneSwitch option is selected, parameters
HighFreqShareRbNum and LowFreqShareRbNum must be set. By
means of spectrum sharing, the idle GERAN spectrum can be used
by the E-UTRAN cell, thereby increasing the bandwidth and
throughput of the E-UTRAN cell.
GUI Value Range:
GLDynSpectrumShareSwitch(GLDynSpectrumShareSwitch),
GLZeroBufferZoneSwitch(GLZeroBufferZoneSwitch)
Unit: None
Actual Value Range: GLDynSpectrumShareSwitch,
GLZeroBufferZoneSwitch
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification: Yes
Impact on Radio Network Performance:
GLDynSpectrumShareSwitch: If this option is selected, the E-
UTRAN cell can use more spectrum resources, and therefore the E-
UTRAN capacity is increased.
GLZeroBufferZoneSwitch: If this option is selected, the E-UTRAN
cell in the GL bufferzone can use the spectrum overlap between the
GSM and LTE, and therefore the E-UTRAN capacity is increased. If
this option is deselected, the E-UTRAN cell in the GL bufferzone
cannot use the spectrum overlap between the GSM and LTE.
Applicable Mode: L

SfnLoadBasedAd SFN Load- Meaning: Indicates whether to enable load-based adaptive


ptSwitch based adjustment in the adaptive SFN/SDMA feature. If this switch is
Adaptive turned on, load-based adaptive adjustment is enabled, which
Switch increases the proportion of joint-scheduling UEs and improves user
experience when the network load is light, and increases the
proportion of independent-scheduling UEs and ensures the spectral
efficiency when the network load is heavy. If this switch is turned off,
load-based adaptive adjustment in the adaptive SFN/SDMA feature
cannot be enabled. This switch applies only to LTE TDD cells.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship:
-Configuration constraints:
The SfnDl2LoadLevelAdptSwitch check box cannot be selected
under the SfnAlgoSwitch parameter in the CellAlgoSwitch MO if the
SfnLoadBasedAdptSwitch parameter in the CellAlgoSwitch is set to
OFF.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this switch is turned on,
load-based adaptive adjustment is enabled, which increases the
proportion of joint-scheduling UEs and improves user experience
when the network load is light, and increases the proportion of
independent-scheduling UEs and ensures the spectral efficiency
when the network load is heavy. If this switch is turned off, load-
based adaptive adjustment in the adaptive SFN/SDMA feature
cannot be enabled.
Applicable Mode: L

PuschIrcAlgoSwit PUSCH Meaning: Indicates the interference rejection combining (IRC)


ch IRC algorithm applied to the PUSCH. This parameter includes the
algorithm following switches:
switch MrcIrcAdptSwitch: Indicates whether to apply MRC/IRC adaptation
on the PUSCH.
SmartIrcSwitch: Indicates whether to apply enhanced 8R IRC
algorithm to the PUSCH. This switch applies only to 8R and 4R
CoMP scenarios in TDD macro eNodeBs.
MrcIrcAdaptivefor2R: Indicates whether to apply MRC/IRC
adaptation on the PUSCH in 2R scenarios. This switch takes effect
only when MrcIrcAdptSwitch is on. If MrcIrcAdaptivefor2R is on, IRC
is applied to the PUSCH in 2R scenarios. If MrcIrcAdaptivefor2R is
off, MRC/IRC adaptation is applied to the PUSCH in 2R scenarios.
In 2R cells established on LBBPc boards: If MrcIrcAdptSwitch is on,
IRC applies to the PUSCH. If MrcIrcAdptSwitch is off, MRC applies
to the PUSCH.
In 2R cells established on LBBPd boards: The setting of
MrcIrcAdaptivefor2R takes effect only when MrcIrcAdptSwitch is on.
If MrcIrcAdptSwitch and MrcIrcAdaptivefor2R are on, MRC/IRC
adaptation applies to the PUSCH. If MrcIrcAdptSwitch is on and
MrcIrcAdaptivefor2R is off, IRC applies to the PUSCH. If
MrcIrcAdptSwitch is off, MRC applies to the PUSCH.
In 2R cells established on the UBBP boards: If MrcIrcAdptSwitch is
on, MRC/IRC adaptation applies to the PUSCH. If MrcIrcAdptSwitch
is off, MRC applies to the PUSCH.
In 4R cells established on the LBBPc, LBBPd, or UBBP boards: If
MrcIrcAdptSwitch is on, MRC/IRC adaptation applies to the PUSCH.
If MrcIrcAdptSwitch is off, MRC applies to the PUSCH.
GUI Value Range: MrcIrcAdptSwitch(MrcIrcAdptSwitch),
SmartIrcSwitch(SmartIrcSwitch),
MrcIrcAdaptivefor2R(MrcIrcAdaptivefor2R)
Unit: None
Actual Value Range: MrcIrcAdptSwitch, SmartIrcSwitch,
MrcIrcAdaptivefor2R
MML Default Value: None
Recommended Value: MrcIrcAdptSwitch:On, SmartIrcSwitch:Off,
MrcIrcAdaptivefor2R:Off
Parameter Relationship:
-Configuration constraints:
In the CellAlgoSwitch MO, if SmartIrcSwitch under
PuschIrcAlgoSwitch is turned on, MrcIrcAdptSwitch under
PuschIrcAlgoSwitch must also be turned on.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: MrcIrcAdptSwitch: If this
switch is turned on, both the uplink coverage in interference
scenarios and the uplink throughput of cell edge UEs (CEUs)
increase. If this switch is turned off, the uplink coverage in
interference scenarios decreases compared with that when this
switch is turned on.
SmartIrcSwitch: If this switch is turned on, both the uplink average
throughput and throughput at the cell edge increase. In addition, the
service drop rate decreases. If this switch is turned off, both the
uplink average throughput and throughput at the cell edge decrease
in interference scenarios compared with that when this switch is
turned on. In addition, the service drop rate increases.
MrcIrcAdaptivefor2R: Compared with the scenario where this switch
is turned off, turning on this switch increases the uplink coverage in
scenarios without interference but slightly decreases the uplink
coverage in scenarios with strong interference.
Applicable Mode: L

ReselecPriAdapt Reselectio Meaning: Indicates whether to enable or disable adaptive dedicated


Switch n Priority cell reselection priority. If this switch is turned on, the eNodeB
Adaptive delivers the dedicated cell reselection priority to a UE when the
Switch following conditions are met: (1) The UE requests to set up an RRC
connection with the cause value being mo-Signalling. (2) The MME
instructs the eNodeB to release the S1 bearer. (3) The eNodeB fails
to obtain the UE capability. If this switch is turned off, the eNodeB
does not deliver dedicated cell reselection priority to a UE even if the
eNodeB fails to obtain the UE capability information.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

AnrFunctionSwitc ANR Meaning: Indicates whether intra-RAT or inter-RAT neighbor


h Function relationship optimization takes effect. This parameter has two
Switch options: One option controls intra-RAT neighbor relationship
optimization, and the other option controls inter-RAT neighbor
relationship optimization.
INTRA_RAT_ANR_SW: Intra-RAT neighbor relationship
optimization takes effect only if this option is selected.
INTER_RAT_ANR_SW: Inter-RAT neighbor relationship
optimization takes effect only if this option is selected.
GUI Value Range: INTRA_RAT_ANR_SW(INTRA_RAT_ANR_SW),
INTER_RAT_ANR_SW(INTER_RAT_ANR_SW)
Unit: None
Actual Value Range: INTRA_RAT_ANR_SW,
INTER_RAT_ANR_SW
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

SfnAlgoSwitch SFN Meaning: Indicates whether to enable algorithms related to single


Algorithm frequency network (SFN).
Switch SfnPdcchDcsSwitch: Indicates whether to enable selective
transmission of PDCCH data in an SFN cell. This option applies only
to TDD. If this option is selected, selective transmission of PDCCH
data is enabled when the adaptive SFN/SDMA feature is enabled. If
this option is deselected, joint transmission or SDMA-based
transmission of PDCCH data is enabled when the adaptive
SFN/SDMA feature is enabled.
SfnUll2SelectiveRcvSwitch: Indicates whether to enable selective
reception of L2 data in an SFN cell. This option applies only to TDD.
If this option is selected, one of the working RF modules of a UE is
selected to receive L2 data of this UE. If this option is deselected, a
target RF module that is originally selected for a UE is fixedly used
to receive L2 data of this UE.
SfnPdcchSdmaSwitch: Indicates whether to enable SDMA-based
transmission of PDCCH data in an SFN cell. This option applies only
to TDD. If this option is selected, SDMA-based transmission of
PDCCH data is enabled when the adaptive SFN/SDMA feature is
enabled. If this option is deselected, joint transmission or selective
transmission of PDCCH data is enabled when the adaptive
SFN/SDMA feature is enabled.
SfnPucchAckSdmaSwitch: Indicates whether to enable SDMA-
based transmission and reception of dynamic ACK over the PUCCH
in an SFN cell. This option applies only to TDD. If this option is
selected, SDMA-based transmission and reception of dynamic ACK
over the PUCCH is enabled when the adaptive SFN/SDMA feature
is enabled. If this option is deselected, SDMA-based transmission
and reception of dynamic ACK over the PUCCH is disabled when
the adaptive SFN/SDMA feature is enabled.
SuperCombCellSwitch: Indicates whether to enable the super
combined cell feature. If this option is selected, the super combined
cell feature is enabled. If this option is deselected, the super
combined cell feature is disabled.
SfnDl2LoadLevelAdptSwitch: Indicates whether to enable downlink
two-load-level adaptation in an SFN cell. This option applies only to
TDD. If this option is selected, downlink two-load-level adaptation is
enabled when the adaptive SFN/SDMA feature is enabled. If this
option is deselected, downlink two-load-level adaptation is disabled
when the adaptive SFN/SDMA feature is enabled.
SfnDlSchAttriAdjsSwitch: Indicates whether to enable downlink
scheduling attribute adjustment in an SFN cell. If this option is
selected, downlink scheduling attribute adjustment is enabled when
the adaptive SFN/SDMA feature is enabled. If this option is
deselected, downlink scheduling attribute adjustment is disabled
when the adaptive SFN/SDMA feature is enabled.
SfnCbfSwitch: Indicates whether to enable coordinated
beamforming (CBF) in an SFN cell. This option applies only to TDD.
If this option is selected, CBF is enabled when the adaptive
SFN/SDMA feature is enabled. If this option is deselected, CBF is
disabled when the Adaptive SFN/SDMA feature is enabled.
SfnVoLteDlJSchSwitch: Indicates whether to enable joint scheduling
for VoLTE UEs in an adaptive SFN cell. This option applies only to
FDD. If this option is selected, joint scheduling is enabled for VoLTE
UEs when the adaptive SFN/SDMA feature is enabled. If this option
is deselected, adaptive scheduling is enabled for VoLTE UEs when
the adaptive SFN/SDMA feature is enabled.
SfnTarRruSelEnhSwitch: Indicates whether to enhance the selection
of an uplink target RF module. When the distance between physical
cells of an SFN cell is greater than 500m, turn on this option. If this
option is selected, the physical layer calibrates received uplink
signals based on TA measurements so that a more appropriate
target RF module can be selected. If this option is deselected, the
physical layer does not calibrate received uplink signals for target
RF module selection.
SfnTarRruAdjSelSwitch: Indicates whether to enable adaptive use of
SINR or RSRP for the selection of an uplink target RF module. If this
option is selected, uplink SINR or uplink RSRP is adaptively used
based on the UE location to select an uplink target RF module. If
this option is deselected, uplink SINR is always used to select an
uplink target RF module.
GUI Value Range: SfnPdcchDcsSwitch(SFNPDCCHDCSSWITCH),
SfnUll2SelectiveRcvSwitch(SfnUll2SelectiveRcvSwitch),
SfnPdcchSdmaSwitch(SFNPDCCHSDMASWITCH),
SfnPucchAckSdmaSwitch(SFNPUCCHACKSDMASWITCH),
SuperCombCellSwitch(SuperCombCellSwitch),
SfnDl2LoadLevelAdptSwitch(SfnDl2LoadLevelAdptSwitch),
SfnDlSchAttriAdjsSwitch(SfnDlSchAttriAdjsSwitch),
SfnCbfSwitch(SfnCbfSwitch),
SfnVoLteDlJSchSwitch(SfnVoLteDlJSchSwitch),
SfnTarRruSelEnhSwitch(SfnTarRruSelEnhSwitch),
SfnTarRruAdjSelSwitch(SfnTarRruAdjSelSwitch)
Unit: None
Actual Value Range: SfnPdcchDcsSwitch,
SfnUll2SelectiveRcvSwitch, SfnPdcchSdmaSwitch,
SfnPucchAckSdmaSwitch, SuperCombCellSwitch,
SfnDl2LoadLevelAdptSwitch, SfnDlSchAttriAdjsSwitch,
SfnCbfSwitch, SfnVoLteDlJSchSwitch, SfnTarRruSelEnhSwitch,
SfnTarRruAdjSelSwitch
MML Default Value: None
Recommended Value: SFNPDCCHDCSSWITCH:Off,
SfnUll2SelectiveRcvSwitch:Off, SFNPDCCHSDMASWITCH:Off,
SFNPUCCHACKSDMASWITCH:Off, SuperCombCellSwitch:Off,
SfnDl2LoadLevelAdptSwitch:Off, SfnDlSchAttriAdjsSwitch:Off,
SfnCbfSwitch:Off, SfnVoLteDlJSchSwitch:Off,
SfnTarRruSelEnhSwitch:Off, SfnTarRruAdjSelSwitch: off
Parameter Relationship:
-Configuration constraints:
In the CellAlgoSwitch,SfnAlgoSwitch can not turn on
SfnPdcchDcsSwitch and SfnPdcchSdmaSwitch simultaneously.
In a CellAlgoSwitch, if SfnDlSchSwitch is not set to ADAPTIVE, then
the SfnAlgoSwitch in CellAlgoSwitch could not turn on
SfnPdcchSdmaSwitch.
In the CellAlgoSwitch MO, if SfnUlSchSwitch is set to ADAPTIVE or
SfnDlSchSwitch is set to ADAPTIVE, SuperCombCellSwitch of
SfnAlgoSwitch must be deselected.
If either PucchSwitch or PucchFlexCfgSwitch of PucchAlgoSwitch in
the CellAlgoSwitch MO is selected, SuperCombCellSwitch of
SfnAlgoSwitch in the CellAlgoSwitch MO must be deselected.
If SuperCombCellSwitch of SfnAlgoSwitch in the CellAlgoSwitch MO
is set to on, SpsSchSwitch of DlSchSwitch in the CellAlgoSwitch MO
must be deselected.
If SuperCombCellSwitch of SfnAlgoSwitch in the CellAlgoSwitch MO
is set to on, SpsSchSwitch of UlSchSwitch in the CellAlgoSwitch MO
must be deselected.
If the SuperCombCellSwitch check box under the SfnAlgoSwitch
parameter in the CellAlgoSwitch MO is selected, the
SrsSubframeRecfSwitch check box under the SrsAlgoSwitch
parameter in the CellAlgoSwitch MO must not be selected.
The SfnDl2LoadLevelAdptSwitch check box cannot be selected
under the SfnAlgoSwitch parameter in the CellAlgoSwitch MO if the
SfnLoadBasedAdptSwitch parameter in the CellAlgoSwitch is set to
OFF.
In the CellAlgoSwitch MO, the TM9MuBfSwitch check box can be
selected under the MuBfAlgoSwitch parameter only if the
MuBfSwitch check box is selected under the MuBfAlgoSwitch
parameter or the SfnCbfSwitch check box is selected under the
SfnAlgoSwitch parameter.
In the CellAlgoSwitch MO, the MubfResAdjSwitch check box can be
selected under the MuBfAlgoSwitch parameter only if both the
following conditions are met:
The MuBfSwitch check box is selected under the MuBfAlgoSwitch
parameter or the SfnCbfSwitch check box is selected under the
SfnAlgoSwitch parameter.
In the CellAlgoSwitch,SfnAlgoSwitch can not turn on
SfnTarRruSelEnhSwitch and SfnTarRruAdjSelSwitch
simultaneously.
Service Interrupted After Modification: The cell is re-established
when the setting of the SuperCombCellSwitch option changes
Impact on Radio Network Performance: SfnPdcchDcsSwitch:
If this option is selected, PDCCH coverage and capacity improve
when the PDCCH is heavily loaded and suffers severe interference.
If this option is deselected, PDCCH reliability can be ensured when
the PDCCH is lightly loaded.
SfnUll2SelectiveRcvSwitch:
If this option is selected, uplink coverage improves.
If this option is deselected, the target RF module of a UE is selected
to receive L2 data of this UE.
SfnPdcchSdmaSwitch:
If this option is selected, PDCCH capacity increases by using
SDMA.
If this option is deselected, joint transmission or selective
transmission of PDCCH data is enabled when the adaptive
SFN/SDMA feature is enabled.
SfnPucchAckSdmaSwitch:
If this option is selected, PDCCH SDMA efficiency increases but
dynamic ACK detection performance deteriorates.
If this option is deselected, dynamic ACK detection performance
improves but PDCCH SDMA efficiency decreases.
SuperCombCellSwitch:
If this option is selected, handovers between SFN cells in a super
combined cell are not perceivable, improving user experience and
increasing the average throughput of UEs in the overlapping area
between SFN cells.
If this option is deselected, the super combined cell feature does not
take effect but common SFN cells still work.
SfnDl2LoadLevelAdptSwitch:
If this option is selected, two-load-level adaptation is enabled,
making SFN more stable.
If this option is deselected, two-load-level adaptation is disabled.
SfnDlSchAttriAdjsSwitch:
If this option is selected, perceivable data rates increase.
If this option is deselected, scheduling is not optimized.
SfnCbfSwitch:
If this option is selected, inter-RF-module CBF reduces interference
and increases cell capacity.
If this option is deselected, inter-RF-module CBF is disabled.
SfnVoLteDlJSchSwitch:
If this option is selected, joint scheduling is enabled for VoLTE UEs,
improving user experience.
If this option is deselected, adaptive scheduling is enabled for
VoLTE UEs, increasing cell capacity but degrading user experience.
SfnTarRruSelEnhSwitch:
If this option is selected, the physical layer calibrates received uplink
signals based on TA measurements so that a more appropriate
target RF module can be selected. However, when the distance
between physical cells is too large, TA measurements may be
inaccurate.
If this option is deselected, target RF modules can be correctly
selected when the time deviation of received uplink signals is small,
but may be incorrectly selected when the time deviation is large.
Applicable Mode: L

PrachIntrfRejSwit Prach Meaning: Indicates whether to suppress interference on the PRACH.


ch Interferenc This parameter takes effect only on the eNodeB uses the LBBPc
e Rejection and one or two RX antennas. If this parameter is set to OFF, the
Switch interference on the PRACH is not suppressed. If this parameter is
set to ON, the PrachIrcSwitch option of the IrcSwitch parameter
takes effect. If the PrachIrcSwitch option of the IrcSwitch parameter
is cleared, interference on the PRACH is suppressed based on the
maximum ratio combining (MRC). If the PrachIrcSwitch option of the
IrcSwitch parameter is selected, interference on the PRACH is
suppressed based on the interference rejection combining (IRC).
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
OFF, the number of false alarms increases may increase in
scenarios of strong interference on the PRACH. If this parameter is
set to ON, the number of false alarms in the PRACH decreases,
random access success rate, handover success rate,
resynchronization rate, and RRC reestablishment success rate
increase. However, UEs in areas with weak coverage may attempt
to access the network, which decreases the RRC setup success
rate.
Applicable Mode: L

EnhMIMOSwitch Enhanced Meaning: Indicates the switch used to enable or disable enhanced
MIMO MIMO. Admitted UEs are allowed to enter TM9 or TM10 mode only
Switch if the TM9Switch or TM10Switch option is selected. The
TM4TM9AdaptiveSwitch option can be selected only after the
TM9Switch option is selected. If the TM4TM9AdaptiveSwitch option
is selected, UEs meeting certain conditions are allowed to adaptively
enter TM4 and TM9 mode. Otherwise, UEs are prohibited from
adaptively entering TM4 and TM9 mode. Enhanced MIMO does not
apply to the LBBPc. The TM4TM9AdaptiveSwitch and TM10Switch
options apply only to FDD.
GUI Value Range: TM9Switch(TM9Switch),
TM4TM9AdaptiveSwitch(TM4TM9AdaptiveSwitch),
TM10Switch(TM10Switch)
Unit: None
Actual Value Range: TM9Switch, TM4TM9AdaptiveSwitch,
TM10Switch
MML Default Value: None
Recommended Value: TM9Switch:Off, TM4TM9AdaptiveSwitch:Off,
TM10Switch:Off
Parameter Relationship:
-Configuration constraints:
Options TM10Switch and TM9Switch of EnhMIMOSwitch in the
CellAlgoSwitch cannot be selected simultaneously.
If the Virtual4T4RSwitch option of EmimoSwitch in the
CellAlgoSwitch MO is selected, options of TM9Switch and
TM10Switch of EnhMIMOSwitch must be deselected.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: TM4TM9AdaptiveSwitch
takes effect when TM9Switch is on, and its setting determines the
transmission modes that the eNodeB with multiple antennas can
select for TM9-supporting UEs. The specific impact of this switch is
as follows:
1) If this switch is off, the transmission modes of all TM9-supporting
UEs in the cell is TM9. For its impact, see the description of
TM9Switch.
2) If this switch is on, the transmission modes of TM9-supporting
UEs of category 6, 7, 9, 10, 11, 12, or 13 in the cell can only be TM4
or TM9, and the peak rates of UEs in TM9 increase.
Applicable Mode: L

InterfRandSwitch Interferenc Meaning: Indicates the interference randomization algorithm applied


e to TDD and FDD eNodeBs.
Randomiz If this parameter is set to OFF, the interference randomization
e algorithm is disabled.
Algorithm
Switch If this parameter is set to ECO_BASED, the eCoordinator-based
interference randomization algorithm is enabled, which applies only
to TDD eNodeBs.
If this parameter is set to ENB_BASED, the eNodeB-based
interference randomization algorithm is enabled, which applies to
both TDD and FDD eNodeBs.
GUI Value Range: OFF(OFF), ECO_BASED(ECO_BASED),
ENB_BASED(ENB_BASED)
Unit: None
Actual Value Range: OFF, ECO_BASED, ENB_BASED
MML Default Value: None
Recommended Value: OFF(OFF)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: This parameter applies to
lightly-loaded networks. If this parameter is set to ENB_BASED,
interference is reduced in a lightly-loaded cell and the spectrum
efficiency is improved, and the MCS is more evenly distributed. If
this parameter is set to ECO_BASED, the eCO-based interference
randomization is enabled and the cell spectrum efficiency is
improved.
Applicable Mode: L

RepeaterSwitch Repeater Meaning: Indicates the type of reference signal (RS) power to be
Switch delivered in system information block type 2 (SIB2). If the
AntRsPwrSwitch option is selected, the RS power calculated based
on the AntOutputPwr parameter value is delivered in SIB2. If the
AntRsPwrSwitch option is not selected, the RS power specified by
the ReferenceSignalPwr parameter is delivered in SIB2. This
parameter applies only to LTE FDD.
GUI Value Range: AntRsPwrSwitch(AntRsPwrSwitch)
Unit: None
Actual Value Range: AntRsPwrSwitch
MML Default Value: None
Recommended Value: AntRsPwrSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: Yes
Impact on Radio Network Performance: None
Applicable Mode: L

MultiFreqPriContr Multi Meaning: Indicates whether to prioritize frequencies in a multi-


olSwitch Frequency frequency network. FixedMeasObjIDSwitch: Indicates whether the
Priority eNodeB maps each neighboring frequency to a MeasObjectID
Control based on the frequency measurement priorities. If this switch is on,
Switch the eNodeB maps each neighboring frequency to a corresponding
MeasObjectID based on the frequency measurement priorities. A
higher-priority frequency is mapped to a smaller MeasObjectID. If
this switch is off, the eNodeB does not map neighboring frequencies
to MeasObjectIDs based on the frequency measurement priorities.
VoipMeasFreqPriSwitch: Indicates whether the frequency priority
specified by the VoipPriority parameter takes effect during coverage-
based handovers for VoIP UEs. If this switch is on, the eNodeB only
delivers the highest-priority intra-RAT frequencies different from the
serving frequency based on the settings of the VoipPriority
parameter when the eNodeB delivers the measurement
configurations to VoIP UEs for coverage-based inter-frequency
handovers. If this switch is off, the eNodeB does not consider the
settings of the VoipPriority parameter when delivering the
measurement configurations to VoIP UEs for coverage-based inter-
frequency handovers.
GUI Value Range: FixedMeasObjIDSwitch(FixedMeasObjIDSwitch),
VoipMeasFreqPriSwitch(VoipMeasFreqPriSwitch),
PsMeasFreqPriSwitch(PsMeasFreqPriSwitch)
Unit: None
Actual Value Range: FixedMeasObjIDSwitch,
VoipMeasFreqPriSwitch, PsMeasFreqPriSwitch
MML Default Value: None
Recommended Value: FixedMeasObjIDSwitch:Off,
VoipMeasFreqPriSwitch:Off,PsMeasFreqPriSwitch:On
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: FixedMeasObjIDSwitch: If
this switch is on, UEs that preferentially measure neighboring
frequencies with a small MeasObjectID can more easily measure
neighboring frequencies with high priorities, and therefore these UEs
can preferentially be handed over to cells on these neighboring
frequencies. VoipMeasFreqPriSwitch: If this switch is on, during the
measurements of coverage-based inter-frequency handovers for
VoIP UEs, the frequencies to be measured are fixed. In this case,
VoIP UEs can preferentially be handed over to frequencies with high
priorities. This mechanism applies to scenarios where operators
require UEs to be handed over to low frequencies with good
coverage, so that the number of handovers can be reduced during
continuous UE movement and the voice quality can be improved. If
the bandwidth of a low frequency is small, the service data rate of
the VoIP UE decreases.
Applicable Mode: L

HarqAlgoSwitch Harq Meaning: Indicates whether to enable or disable HARQ-related


Algorithm algorithms. If the TddAckFbModeCfgOptSwitch is on, the HARQ-
Switch ACK feedback mode is reconfigured based on UE services. If the
TddAckFbModeCfgOptSwitch is off, the HARQ-ACK feedback mode
is not reconfigured based on UE services.
GUI Value Range:
TddAckFbModeCfgOptSwitch(TddAckFbModeCfgOptSwitch)
Unit: None
Actual Value Range: TddAckFbModeCfgOptSwitch
MML Default Value: None
Recommended Value: TddAckFbModeCfgOptSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If the
TddAckFbModeCfgOptSwitch is on, the TDD HARQ-ACK feedback
mode is adaptively configured based on the PDCCH load and UE
services in the cell, which leads to increased UEs with the TDD
HARQ-ACK feedback mode configured to multiplexing mode.
Compared with the bundling mode, the multiplexing mode increases
the MCSs. However, due to no DTX state in multiplexing mode, the
CCE aggregation level of PDCCH data cannot be accurately
determined and the PDCCH power control cannot be accurately
performed, which reduces the PDCCH reliability. As a result, the
handover success rate, call drop rate, ping delay, and PUCCH
coverage performance may deteriorate, while the cell throughput,
single user throughput, and perceptive rate may increase. If the
TddAckFbModeCfgOptSwitch is off, the TDD HARQ-ACK feedback
mode is not reconfigured based on the PDCCH load and UE
services. Most UEs use the bundling mode for HARQ-ACK
feedback, without reducing the PDCCH reliability. In addition, the
handover success rate, call drop rate, ping delay, PUCCH coverage
performance, and access delay may be optimized, while the cell
throughput, single user throughput, and perceptive rate may
decrease.
Applicable Mode: L

CovBasedInterFr Coverage Meaning: Indicates the coverage-based inter-frequency handover


eqHoMode Based mode. If this parameter is set to
Inter HANDOVERIMMEDIATELY(Handover Immediately), the eNodeB
Frequency immediately determines whether to perform a coverage-based inter-
Handover frequency handover when receiving a measurement report. If this
Mode parameter is set to BASEDONSIGNALSTRENGTH(Based on Signal
Strength), the eNodeB waits a moment and then determines
whether to perform a coverage-based inter-frequency handover to
the strongest neighboring cell indicated by the received
measurement reports. If this parameter is set to
BASEDONFREQPRIORITY(Based on Frequency Priority), the
eNodeB waits a moment and then determines whether to perform a
coverage-based inter-frequency handover to a cell whose frequency
has a relatively low priority.
GUI Value Range:
HANDOVERIMMEDIATELY(HANDOVERIMMEDIATELY),
BASEDONSIGNALSTRENGTH(BASEDONSIGNALSTRENGTH),
BASEDONFREQPRIORITY(BASEDONFREQPRIORITY)
Unit: None
Actual Value Range: HANDOVERIMMEDIATELY,
BASEDONSIGNALSTRENGTH, BASEDONFREQPRIORITY
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
HANDOVERIMMEDIATELY, the eNodeB immediately determines
whether to perform a coverage-based inter-frequency handover
when receiving a measurement report. This ensures that UEs are
handed over in time. If this parameter is set to
BASEDONSIGNALSTRENGTH, UEs can be handed over to the
strongest neighboring cells. However, the waiting time puts off the
handover, increases the handover failure rate, and causes service
drops. If this parameter is set to BASEDONFREQPRIORITY, the
possibility that UEs are handed over to neighboring cells whose
frequency has a high priority increases. This helps these
neighboring cells absorb more traffic, but puts off the handover,
increases the handover failure rate, and causes service drops.
Applicable Mode: L

LteUtcBroadcast Lte Utc Meaning: Indicates whether the eNodeB broadcasts the coordinated
Switch Broadcast universal time (UTC) in the LTE system over the air interface. If this
Switch parameter is set to 1, the eNodeB broadcasts the UTC in the LTE
system using system information block type 16 (SIB16). If this
parameter is set to 0, the eNodeB does not broadcast the UTC in
the LTE system.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: Setting this parameter to
ON increases air interface overheads for broadcasting UTC in the
LTE system through SIB16.
Applicable Mode: L

CellSchStrategyS Cell Meaning: Indicates whether to enable a specific scheduling policy in


witch Schedule the uplink and downlink.
Strategy AbnUeSchSwitch: Indicates whether to disable scheduling of
Switch abnormal UEs. If this switch is on, abnormal UEs are not scheduled.
If this switch is off, abnormal UEs are scheduled.
GUI Value Range: AbnUeSchSwitch(AbnUeSchSwitch)
Unit: None
Actual Value Range: AbnUeSchSwitch
MML Default Value: None
Recommended Value: AbnUeSchSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: AbnUeSchSwitch: Turning
off this switch has no impact on network performance. If this switch
is on, scheduling of abnormal UEs is disabled in the uplink and
downlink, and resource efficiency increases. As a result, cell
throughput increases in scenarios where resources are insufficient.
However, the scheduling delay increases, perceived throughput
decreases, and service drop rate increases for UEs in weak
coverage areas.
Applicable Mode: L

SsrdAlgoSwitch SSRD Meaning: Indicates whether to enable the Soft Split Resource
Algorithm Duplex (SSRD) algorithm.
Switch SsrdDl8TAlgoSwitch: If this switch is on, the soft split multi-user
pairing algorithm is enabled in the downlink.
If this switch is off, the soft split multi-user pairing algorithm is
disabled in the downlink.
GUI Value Range: Ssrd8T8RAlgoSwitch(Ssrd8T8RAlgoSwitch)
Unit: None
Actual Value Range: Ssrd8T8RAlgoSwitch
MML Default Value: None
Recommended Value: Ssrd8T8RAlgoSwitch:Off
Parameter Relationship:
-Configuration constraints:
In the CellAlgoSwitch, SsrdAlgoSwitch is set to On only when
BfAlgoSwitch has been set to On.
-Others:
In the CellAlgoSwitch, SsrdAlgoSwitch and MuBfAlgoSwitch cannot
be set to On simultaneously.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: Ssrd8T8RAlgoSwitch: If this
switch is on, increases the average downlink throughput in a heavily
loaded cell. If a cell is lightly loaded or soft split multi-user pairing is
not required, set this switch to off.
Applicable Mode: L

SfnUplinkCompS SFN Meaning: Indicates whether to enable uplink CoMP in SFN cells.
witch Uplink If both the IntraBaseBandSwitch and InterBaseBandSwitch options
Comp are deselected, UL CoMP is disabled in an SFN cell.
Switch
If the IntraBaseBandSwitch option is selected and the
InterBaseBandSwitch option is deselected, Intra-BBP UL CoMP is
enabled in an SFN cell.
If both the IntraBaseBandSwitch and InterBaseBandSwitch options
are selected, both intra-BBP UL CoMP and inter-BBP UL CoMP are
enabled in an SFN cell.
If the IntraBaseBandSwitch option is deselected and the
InterBaseBandSwitch option is selected this setting is invalid.
If the ComCoverUlCompSwitch option is selected, UL CoMP is
supported when multiple RF modules provide the same coverage in
an SFN cell.
If the ComCoverUlCompSwitch option is deselected, UL CoMP is
not supported when multiple RF modules provide the same
coverage in an SFN cell.
ComCoverUlCompSwitch applies only to TDD.
SfnUplinkComp3CellSwitch: This option takes effect when the
IntraBaseBandSwitch or InterBaseBandSwitch option is selected.
If the SfnUplinkComp3CellSwitch option is selected, UL CoMP is
supported in three physical cells of an SFN cell.
If the SfnUplinkComp3CellSwitch option is deselected: UL CoMP is
supported in two physical cells of an SFN cell.
SfnUplinkComp3CellSwitch applies only to FDD.
GUI Value Range: IntraBaseBandSwitch(IntraBaseBandSwitch),
InterBaseBandSwitch(InterBaseBandSwitch),
ComCoverUlCompSwitch(ComCoverUlCompSwitch),
SfnUplinkComp3CellSwitch(SfnUplinkComp3CellSwitch)
Unit: None
Actual Value Range: IntraBaseBandSwitch, InterBaseBandSwitch,
ComCoverUlCompSwitch, SfnUplinkComp3CellSwitch
MML Default Value: None
Recommended Value: IntraBaseBandSwitch: Turning on this switch
is recommended because intra-BBP UL CoMP can increase the
average uplink throughput and improve the uplink coverage of an
SFN cell.
InterBaseBandSwitch: Turning on this switch is recommended
because intra-BBP UL CoMP can increase the average uplink
throughput and improve the uplink coverage of an SFN cell.
ComCoverUlCompSwitch: Turning off this switch is recommended if
multiple RF modules provide different coverages in an SFN cell.
SfnUplinkComp3CellSwitch: Turning on this switch is recommended
when an SFN cell is composed of three or more physical cells.
Parameter Relationship:
-Configuration constraints:
If the InterBaseBandSwitch check box under the
SfnUplinkCompSwitch parameter in the CellAlgoSwitch MO is
selected, the IntraBaseBandSwitch check box under the
SfnUplinkCompSwitch parameter must be selected.
If the SfnUplinkComp3CellSwitch check box under the
SfnUplinkCompSwitch parameter in the CellAlgoSwitch MO is
selected, the IntraBaseBandSwitch check box under the
SfnUplinkCompSwitch parameter must be selected.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: IntraBaseBandSwitch:
Turning on this switch increases the uplink throughput of cell edge
users (CEUs in the overlapping coverage areas of multiple RF
modules in an SFN cell) and the average uplink throughput of the
SFN cell. The increase in the uplink CEU throughput indicates that
the uplink coverage improves.
InterBaseBandSwitch: Turning on this switch enables inter-BBP UL
CoMP in an SFN cell. This further increases the uplink CEU
throughput and the average uplink throughput of the SFN cell. The
increase in the uplink CEU throughput indicates that the uplink
coverage improves.
ComCoverUlCompSwitch: Turning on this switch increases the
uplink CEU throughput when multiple RF modules provide the same
coverage in an SFN cell and the average uplink throughput of the
SFN cell. The increase in the uplink CEU throughput indicates that
the uplink coverage improves.
SfnUplinkComp3CellSwitch: Turning on this switch enables UL
CoMP to be performed on qualified UEs in three physical cells of an
SFN cell. This further increases the uplink CEU throughput and the
average uplink throughput of the SFN cell.
Applicable Mode: L

LowSpeedInterFr Low Speed Meaning: Indicates whether to enable the inter-frequency directional
eqHoSwitch User Inter- handover algorithm for low-speed UEs. If this switch is turned on,
frequency the eNodeB instructs low-speed UEs in RRC_CONNECTED mode
Handover in networks dedicated to high-speed railways to measure low-speed
Switch inter-frequency cells to hand over the UEs to low-speed inter-
frequency cells.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If the
LowSpeedInterFreqHoSwitch parameter is set to ON, low-speed
UEs are handed over to inter-frequency neighboring cells with low-
speed frequencies, ensuring that the capacity of networks dedicated
to high-speed railways is not occupied by UEs in macro networks.
Applicable Mode: L

RelaySwitch Relay Meaning: Indicates whether to enable or disable the relay-related


Switch functions.
OutOfBandRelaySwitch: Indicates whether to enable or disable the
out-of-band relay feature. If this switch is on, the out-of-band relay
feature is enabled. If this switch is off, the out-of-band Relay function
is disabled.
GUI Value Range: OutOfBandRelaySwitch(OutOfBandRelaySwitch)
Unit: None
Actual Value Range: OutOfBandRelaySwitch
MML Default Value: None
Recommended Value: OutOfBandRelaySwitch:Off
Parameter Relationship:
-Configuration constraints:
EicicSwitch in the CellAlgoSwitch MO cannot be set to STATIC or
DYNAMIC when OutOfBandRelaySwitch under the RelaySwitch
parameter is turned on.
OutOfBandRelaySwitch under the RelaySwitch parameter in the
CellAlgoSwitch MO cannot be turned on when
MBSFNShutDownSwitch under the DlSchSwitch parameter is
turned on.
OutOfBandRelaySwitch under the RelaySwitch parameter in the
CellAlgoSwitch MO cannot be turned on when TtiBundlingSwitch
under the UlSchSwitch parameter is turned on.
OutOfBandRelaySwitch under the RelaySwitch parameter in the
CellAlgoSwitch MO cannot be turned on when UlIicsAlgoSwitch
under the UlSchSwitch parameter is turned on.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: OutOfBandRelaySwitch: If
this switch is on, the number of common UEs that can access the
cell decreases, both the total throughput of common UEs in the cell
and the peak throughput of a single common UE decrease (the
decrease rate is in positive correlation with the number of resources
occupied by relay subframes), and the relayed UEs can access the
cell. If this switch is off, the number of common UEs that can access
the cell increases, throughput of common UEs may increase, and
relayed UEs that have accessed the cell are released, and services
of the relayed UEs are interrupted.
Applicable Mode: L
InterFreqDirectH Inter- Meaning: Indicates whether to enable the inter-frequency directional
oSwitch frequency handover algorithm. If this switch is turned on, the eNodeB instructs
Directional UEs in RRC_CONNECTED mode in networks dedicated to high-
Handover speed railways to measure inter-frequency cells to hand over the
Switch UEs to high-speed inter-frequency cells.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

PwrDeratSwitch Power Meaning: Indicates whether to apply the power decrease


Derating mechanism on reference signal (RS) power and physical
Switch synchronization channel (PSCH) power. If this parameter is set
OFF, the physical downlink shared channel (PDSCH) transmit
power is lowered, the RS power and PSCH power are not lowered.
If this parameter is set to ON, all of the PDSCH power, RS power,
and PSCH power are lowered.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
OFF, the cell coverage does not shrink and cell throughput
decreases. If this parameter is set to ON, the cell coverage shrinks
and cell throughput does not decrease.
Applicable Mode: L

DetectionAlgoSwi DetectionA Meaning: Indicates whether channel quality indicator (CQI) detection
tch lgoSwitch errors can be identified in the presence of interference. If this switch
is on, CQI detection errors can be identified, and a historical CQI is
used in the eNodeB. If this switch is off, CQI detection errors cannot
be identified in the presence of interference.
GUI Value Range: CqiReliableSwitch(CqiReliableSwitch)
Unit: None
Actual Value Range: CqiReliableSwitch
MML Default Value: None
Recommended Value: CqiReliableSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L
PucchIRCEnhanc Pucch IRC Meaning: Indicates whether the eNodeB determines interference
e Enhance strength. The eNodeB determines interference strength only when
this switch is 1, which ensures accurate adaptive switchover
between maximum ratio combining (MRC) and interference rejection
combining (IRC). This parameter takes effect only when
PucchIrcSwitch of the IrcSwitch parameter is 1.
When PucchIrcSwitch is 0, setting the PucchIRCEnhance parameter
to ON and turning on PucchIrcSwitch improves the PUCCH
detection performance, compared with the scenarios where
PucchIrcSwitch is 0 and the PucchIRCEnhance parameter is set to
0.
In scenarios with PucchIrcSwitch turned on, setting the
PucchIRCEnhance parameter to ON decreases the number of false
PUCCH detections and also slightly decreases PUCCH detection
performance compared with the PucchIRCEnhance parameter set to
0.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: The detection performance
is better when the PucchIrcSwitch option of the IrcSwitch parameter
is selected and the PucchIrcEnhance parameter is set to ON(On)
than when the PucchIrcSwitch option is deselected.
If the PucchIrcSwitch option of the IrcSwitch parameter is selected,
the false-alarm probability and uplink BLER decrease when the
setting of the PucchIrcEnhance parameter is changed from OFF(Off)
to ON(On); however, the detection performance slightly deteriorates
and the ping delay slightly increases.
Applicable Mode: L

AcBarAlgoforDyn Ac Bar Meaning: Indicates whether to enable intelligent access barring


Switch Algorithm algorithms. This parameter controls whether to enable intelligent
Switch for access barring on mobile-originated (MO) signaling, MO data,
Dynamic service specific access control (SSAC) for multimedia telephony
(MMTEL) voice services, or SSAC for MMTEL video services. This
parameter takes effect only when the AcBarAlgoSwitch parameter in
the CellAlgoSwitch MO is set to ACBAR_SWITCH_DYNAMIC.
DYNAMIC_FOR_MO: Indicates whether to enable intelligent access
barring on UEs running MO signaling or MO data.
If this switch is on, intelligent access barring applies to UEs running
MO signaling or MO data.
If this switch is off, intelligent access barring does not apply to UEs
running MO signaling or MO data.
DYNAMIC_FOR_SSAC: Indicates whether to enable intelligent
access barring on UEs running MMTEL voices services or MMTEL
video services.
If this switch is on, intelligent access barring applies to UEs running
MMTEL voices services or MMTEL video services.
If this switch is off, intelligent access barring does not apply to UEs
running MMTEL voices services or MMTEL video services.
GUI Value Range: DYNAMIC_FOR_MO(DYNAMIC_FOR_MO),
DYNAMIC_FOR_SSAC(DYNAMIC_FOR_SSAC)
Unit: None
Actual Value Range: DYNAMIC_FOR_MO, DYNAMIC_FOR_SSAC
MML Default Value: None
Recommended Value: DYNAMIC_FOR_MO:On,
DYNAMIC_FOR_SSAC:Off
Parameter Relationship:
-Configuration constraints:
In the CellAlgoSwitch MO, if AcBarAlgoSwitch is set to
ACBAR_SWITCH_DYNAMIC, either the DYNAMIC_FOR_MO or
DYNAMIC_FOR_SSAC option of AcBarAlgoforDynSwitch must be
selected.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: DYNAMIC_FOR_MO: If this
switch is on, the access probability factor for MO Data and MO
signaling are dynamically adjusted based on the current cell load. In
this way, the probability of UEs accessing the cell can be controlled
to relieve the cell load. However, user experience of barred UEs is
affected. If this switch is off, has the opposite effects.
DYNAMIC_FOR_SSAC: If this switch is on, the access probability
factor for MMTEL voice services and MMTEL video services are
dynamically adjusted based on the current cell load. In this way, the
probability of UEs accessing the cell can be controlled to relieve the
cell load. However, user experience of barred UEs is affected. If this
switch is off, has the opposite effects.
Applicable Mode: L

CreSwitch CRE Meaning: Indicates whether the CellRangeExpansion parameter


Switch takes effect in a HetNet.
If this parameter is set to OFF and static or dynamic eICIC is
enabled, the CellRangeExpansion parameter takes effect.
If this parameter is set to ON and dynamic eICIC is enabled, the
CellRangeExpansion parameter takes effect according to the
dynamic eICIC algorithm; If this switch is turned on in other cases
(that is, dynamic eICIC is disabled, static eICIC is enabled, or static
eICIC is disabled), the CellRangeExpansion parameter takes effect
for all UEs (including R8 and R9 UEs) in the cell.
For macro and micro cells in a HetNet, it is recommended that this
parameter be set to the same value.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
ON for a HetNet, the CellRangeExpansion parameter can be set to
increase the number of UEs that a micro cell can accommodate,
balance loads between macro and micro cells, and improve cell
edge coverage. However, if the CellRangeExpansion parameter
value exceeds a threshold while eICIC is not enabled, the handover
success rate may decrease and the service drop rate may increase.
If this parameter is set to OFF, a micro cell can accommodate a few
number of UEs; in this case, the CellRangeExpansion parameter
cannot be used to balance loads between macro and micro cells or
improve cell edge coverage.
Applicable Mode: L

BackoffAlgoSwitc Backoff Meaning: Indicates whether MLB for low-efficiency UEs is enabled.
h Algorithm The InterFreqBackoffSwitch check box under this parameter
Switch indicates whether inter-frequency MLB for low-efficiency UEs is
enabled.
When this check box is selected, inter-frequency MLB for low-
efficiency UEs is enabled. When this check box is deselected, inter-
frequency MLB for low-efficiency UEs is disabled.
This parameter applies only to LTE TDD cells.
GUI Value Range: InterFreqBackoffSwitch(InterFreqBackoffSwitch)
Unit: None
Actual Value Range: InterFreqBackoffSwitch
MML Default Value: None
Recommended Value: InterFreqBackoffSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: When the
InterFreqBackoffSwitch check box is selected, low-efficiency UEs
are selected for MLB, thereby improving the average cell
throughput. When this check box is deselected, low-efficiency UEs
are not selected for MLB. In this situation, the average cell
throughput cannot reach its maximum.
Applicable Mode: L

HoAllowedSwitch Handover Meaning: Indicates whether to enable eNodeB-level handovers to be


Allowed activated in the cell when related eNodeB-level handover switches
Switch are on. SrvBasedInterFreqHoSw: Indicates whether to enable
service-based inter-frequency handover to be activated in the cell.
Service-based inter-frequency handover is allowed to be activated in
the cell only when this switch is on. GeranSepOpMobilitySwitch:
Indicates whether to differentiate mobility policies for GERAN
operators. When this switch is on, different network policies can be
applied to different GERAN operators. Such policies include SRVCC
and SI obtaining through RIM procedures. When this switch is off,
different network policies cannot be applied to different GERAN
operators. This option applies only to FDD cells. UtranCsfbSwitch:
Indicates whether to enable CSFB for UTRAN. When this switch is
on, CSFB to UTRAN is allowed. When this switch is off, the UTRAN
CSFB algorithm is disabled. If eNodeB-level UtranCsfbSwitch is on,
local-cell-level parameter settings do not take effect. If eNodeB-level
UtranCsfbSwitch is off, local-cell-level parameter settings take
effect. GeranCsfbSwitch: Indicates whether to enable CSFB for
GERAN. When this switch is on, CSFB to GERAN is allowed. When
this switch is off, the GERAN CSFB algorithm is disabled. If
eNodeB-level GeranCsfbSwitch is on, local-cell-level parameter
settings do not take effect. If eNodeB-level GeranCsfbSwitch is off,
local-cell-level parameter settings take effect.
UtranFlashCsfbSwitch: This switch does not take effect if
UtranCsfbSwitch is off. When the UtranFlashCsfbSwitch is on, flash
CSFB to UTRAN is enabled, and UTRAN system information is
carried during redirection. When the UtranFlashCsfbSwitch is off,
flash CSFB to UTRAN is disabled. If eNodeB-level
UtranFlashCsfbSwitch is on, local-cell-level parameter settings do
not take effect. If eNodeB-level UtranFlashCsfbSwitch is off, local-
cell-level parameter settings take effect. GeranFlashCsfbSwitch:
This switch does not take effect if GeranCsfbSwitch is off. When the
GeranFlashCsfbSwitch is on, flash CSFB to GERAN is enabled, and
GERAN system information is carried during redirection. When the
GeranFlashCsfbSwitch is off, flash CSFB to GERAN is disabled. If
eNodeB-level GeranFlashCsfbSwitch is on, local-cell-level
parameter settings do not take effect. If eNodeB-level
GeranFlashCsfbSwitch is off, local-cell-level parameter settings take
effect. CsfbAdaptiveBlindHoSwitch: This switch does not take effect
if BlindHoSwitch is off. If both the BlindHoSwitch and
UFCsfbBlindHoDisSwitch options are selected, the
CsfbAdaptiveBlindHoSwitch option of the HoAlgoSwitch parameter
does not take effect when a UE is handed over to a UTRAN or
GERAN cell using ultra-flash CS fallback. When this switch is on,
CSFB adaptive blind handover is enabled. In this situation, an
optimal handover mode is used depending on UE position in the
CSFB scenario. When this switch is off, CSFB adaptive blind
handover is disabled. If eNodeB-level CsfbAdaptiveBlindHoSwitch is
on, local-cell-level parameter settings do not take effect. If eNodeB-
level CsfbAdaptiveBlindHoSwitch is off, local-cell-level parameter
settings take effect. UtranCsfbSteeringSwitch: UTRAN CSFB
steering is enabled when this switch is on. In this case, RRC_IDLE
UEs can use separate configuration policies when triggering CSFB.
UTRAN CSFB steering is disabled when this switch is off. If
eNodeB-level UtranCsfbSteeringSwitch is on, local-cell-level
parameter settings do not take effect. If eNodeB-level
UtranCsfbSteeringSwitch is off, local-cell-level parameter settings
take effect. GeranCsfbSteeringSwitch: GERAN CSFB steering is
enabled when this switch is on. In this case, RRC_IDLE UEs can
use separate configuration policies when triggering CSFB. GERAN
CSFB steering is disabled when this switch is off. If eNodeB-level
GeranCsfbSteeringSwitch is on, local-cell-level parameter settings
do not take effect. If eNodeB-level GeranCsfbSteeringSwitch is off,
local-cell-level parameter settings take effect.
GUI Value Range:
SrvBasedInterFreqHoSw(SrvBasedInterFreqHoSw),
GeranSepOpMobilitySwitch(GeranSepOpMobilitySwitch),
UtranCsfbSwitch(UtranCsfbSwitch),
GeranCsfbSwitch(GeranCsfbSwitch),
UtranFlashCsfbSwitch(UtranFlashCsfbSwitch),
GeranFlashCsfbSwitch(GeranFlashCsfbSwitch),
CsfbAdaptiveBlindHoSwitch(CsfbAdaptiveBlindHoSwitch),
UtranCsfbSteeringSwitch(UtranCsfbSteeringSwitch),
GeranCsfbSteeringSwitch(GeranCsfbSteeringSwitch)
Unit: None
Actual Value Range: SrvBasedInterFreqHoSw,
GeranSepOpMobilitySwitch, UtranCsfbSwitch, GeranCsfbSwitch,
UtranFlashCsfbSwitch, GeranFlashCsfbSwitch,
CsfbAdaptiveBlindHoSwitch, UtranCsfbSteeringSwitch,
GeranCsfbSteeringSwitch
MML Default Value: None
Recommended Value: SrvBasedInterFreqHoSw:On,
GeranSepOpMobilitySwitch:Off, UtranCsfbSwitch:Off,
GeranCsfbSwitch:Off, UtranFlashCsfbSwitch:Off,
GeranFlashCsfbSwitch:Off, CsfbAdaptiveBlindHoSwitch:Off,
UtranCsfbSteeringSwitch:Off, GeranCsfbSteeringSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: SrvBasedInterFreqHoSw: If
ServiceBasedInterFreqHoSwitch of the HoAlgoSwitch parameter in
the ENodeBAlgoSwitch MO is off, the setting of
SrvBasedInterFreqHoSw has no impact on network performance. If
ServiceBasedInterFreqHoSwitch of the HoAlgoSwitch parameter in
the ENodeBAlgoSwitch MO is on, turning on
SrvBasedInterFreqHoSw enables the cell to use the same service
steering policies as other cells and improves the network
performance based on service steering; turning off
SrvBasedInterFreqHoSw disables the cell to use service steering.
GeranSepOpMobilitySwitch: When this switch is on, different
network policies can be applied to different GERAN operators. Such
policies include SRVCC and SI obtaining through RIM procedures.
In this way, operators supporting SRVCC or RIM procedures can
select an optimal network policy to achieve the best performance.
When this switch is off, a uniform network policy is applied to
different GERAN operators. That is, operators cannot utilize the best
network performance according to their network characteristics.
Applicable Mode: L

NCellClassMgtS Neighbor Meaning: Indicates neighboring cell classification management. This


w Cell parameter includes the following options:
Classificati INTRA_RAT_NCELL_CLASS_SW: If this option is selected, intra-
on Mgt RAT event-triggered ANR or intra-RAT fast ANR is enabled, and the
Switch ANR indicator is set to ALLOWED for this frequency, the eNodeB
automatically marks the NCellClassLabel parameter value as
FORMAL or EXTENDED for intra-RAT neighboring cells based on
handover-related statistic results.
NCELL_CLASS_HO_POLICY_SW: If this option is selected, intra-
RAT event-triggered ANR is enabled, and the ANR indicator is set to
ALLOWED for this frequency, target cells for handovers must be
determined based on E-UTRAN cell global identifier (ECGI) reading
on intra-RAT neighboring cells whose NCellClassLabel parameter
value is EXTENDED.
NCELL_CLASS_PCI_CONFLICT_SW: If this option is selected and
PCI conflict detection is enabled, PCI conflict detection and reporting
are not performed on the neighboring cells whose NCellClassLabel
parameter value is EXTENDED.
UTRAN_NCELL_CLASS_SW: If this option is selected, event-
triggered ANR with UTRAN or fast ANR with UTRAN is enabled,
and the ANR indicator is set to ALLOWED for this UTRAN
frequency, the eNodeB automatically marks the NCellClassLabel
parameter value as FORMAL or EXTENDED for neighboring
UTRAN cells based on handover-related statistic results.
GERAN_NCELL_CLASS_SW: If this option is selected, event-
triggered ANR with GERAN or fast ANR with GERAN is enabled,
and the ANR indicator is set to ALLOWED for this GERAN
frequency, the eNodeB automatically marks the NCellClassLabel
parameter value as FORMAL or EXTENDED for neighboring
GERAN cells based on handover-related statistic results.
EXTENDED_NCELL_MNG_SW: In intra-RAT neighboring cells, if
this option is selected, the eNodeB writes intra-RAT neighboring
cells whose NCellClassLabel parameter value is EXTENDED in the
memory to the configuration database when any of the following
conditions is met:
a. The IntraRatNcellMgtMode parameter value is changed from
INTERNAL_STORAGE_MODE(StorageMode) to
CONFIGURATION_MODE(ConfigMode).
b. Intra-RAT event-triggered ANR and intra-RAT fast ANR are
disabled.
c. The INTRA_RAT_NCELL_CLASS_SW option is deselected.
d. The ANR indicator is set to NOT_ALLOWED for an intra-RAT
frequency.
e. The value of the OptMode parameter in the ANR MO is changed
from FREE(FREE) to CONTROLLED(CONTROLLED).
If this option is deselected, the eNodeB directly discards intra-RAT
neighboring cells whose NCellClassLabel parameter value is
EXTENDED in the memory.
In neighboring UTRAN (or GERAN) cells, if this option is selected,
the eNodeB writes neighboring UTRAN (or GERAN) cells whose
NCellClassLabel parameter value is EXTENDED in the memory to
the configuration database when any of the following conditions is
met:
a. Event-triggered ANR with UTRAN (or GERAN) and fast ANR with
UTRAN (or GERAN) are disabled.
b. The UTRAN_NCELL_CLASS_SW (or
GERAN_NCELL_CLASS_SW) option is deselected.
c. The ANR indicator is set to NOT_ALLOWED for the UTRAN (or
GERAN) frequency.
d. The value of the OptMode parameter in the ANR MO is changed
from FREE(FREE) to CONTROLLED(CONTROLLED). If this option
is deselected, the eNodeB directly discards neighboring UTRAN (or
GERAN) cells whose NCellClassLabel parameter value is
EXTENDED in the memory. If this option is selected and the
CONFUSION_DETECT_SWITCH option of the
PciConflictDetectSwitch parameter is selected, PCI conflict detection
and reporting are not performed on the neighboring cells whose
NCellClassLabel parameter value is EXTENDED in the memory.
GUI Value Range:
INTRA_RAT_NCELL_CLASS_SW(INTRA_RAT_NCELL_CLASS_S
W),
NCELL_CLASS_HO_POLICY_SW(NCELL_CLASS_HO_POLICY_
SW),
NCELL_CLASS_PCI_CONFLICT_SW(NCELL_CLASS_PCI_CONF
LICT_SW),
UTRAN_NCELL_CLASS_SW(UTRAN_NCELL_CLASS_SW),
GERAN_NCELL_CLASS_SW(GERAN_NCELL_CLASS_SW),
EXTENDED_NCELL_MNG_SW(EXTENDED_NCELL_MNG_SW)
Unit: None
Actual Value Range: INTRA_RAT_NCELL_CLASS_SW,
NCELL_CLASS_HO_POLICY_SW,
NCELL_CLASS_PCI_CONFLICT_SW,
UTRAN_NCELL_CLASS_SW, GERAN_NCELL_CLASS_SW,
EXTENDED_NCELL_MNG_SW
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance:
NCELL_CLASS_HO_POLICY_SW: If this option is selected and the
NCellClassLabel parameter value is EXTENDED in intra-RAT
neighboring cells, the target cells for handovers are determined
based on ECGI reading. ECGI reading helps detect potential
neighboring cells with conflicted PCIs but affects user experience. If
this option is deselected, the efficiency of detecting potential
neighboring cells with conflicted PCIs decreases, and the probability
of handovers to inappropriate cells with conflicted PCIs increases.
As a result, the handover success rate decreases.
INTRA_RAT_NCELL_CLASS_SW/NCELL_CLASS_PCI_CONFLIC
T_SW: The setting of this option has no impact on network
performance.
EXTENDED_NCELL_MNG_SW: If this option is deselected,
neighboring cells whose NCellClassLabel parameter value is
EXTENDED in the memory are discarded, and CGIs of these
neighboring cells must be re-read if handovers to these neighboring
cells are initiated. CGI re-reading decreases UE throughput and
delays handovers. As a result, service drops may occur. Selecting
this option has no impact on network performance.
Applicable Mode: L

SpePCIBasedPol Specified Meaning: Indicates whether to enable PCI-based algorithms. This


icySw PCI Based parameter includes the following switches:
Policy IntraAnrPolicySwitch: Indicates whether to enable PCI-based intra-
Switch RAT ANR. If this option is selected and intra-RAT event-triggered
ANR or intra-RAT fast ANR is enabled, PCI-based intra-RAT ANR is
enabled to construct and optimize neighboring relationships
between common cells and cells with special PCIs.
PciConflictDetectPolicySwitch: Indicates whether to enable PCI-
based PCI conflict detection. If this option is selected and PCI
conflict detection is enabled, PCI-based PCI conflict detection is
enabled. If the eNodeB attempts to configure a cell with a special
PCI that operates on the same frequency and has the same PCI
with any configured neighboring cell of a common cell as another
neighboring cell of the common cell, PCI confusion detection is not
performed on the cell with a special PCI.
If the PCI of a cell is within the value range specified by parameters
in EutranSpePciCell MOs, this cell is a cell with special PCI;
otherwise, this cell is a common cell.
GUI Value Range:
IntraAnrPolicySwitch(INTRA_ANR_POLICY_SWITCH),
PciConflictDetectPolicySwitch(PCI_CONFLICT_DETECT_POLICY_
SWITCH)
Unit: None
Actual Value Range: IntraAnrPolicySwitch,
PciConflictDetectPolicySwitch
MML Default Value: None
Recommended Value: IntraAnrPolicySwitch:Off,
PciConflictDetectPolicySwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: IntraAnrPolicySwitch: If this
option is selected, a UE reads CGIs of neighboring cells to discover
neighboring cells and to enable the eNodeB to maintain the NRT
and determine the target cells for handovers during the movement
from a common cell towards cells with special PCIs. CGI reading
helps decrease handover failures caused by PCI confusion but
decreases UE throughput.
If this option is deselected, a UE does not distinguish common cells
from cells with special PCIs during handovers. Instead, the UE
selects target cells based on neighbor relationships in NRTs. As a
result, the handover success rate decreases when PCI confusion
occurs between neighboring cells.
PciConflictDetectPolicySwitch: If this option is selected, the eNodeB
attempts to configure a cell with a special PCI that operates on the
same frequency and has the same PCI with any configured
neighboring cell of a common cell as another neighboring cell of the
common cell, and PCI confusion detection is not performed on the
cell with a special PCI. Selecting this option has no impact on
network performance.
Applicable Mode: L

CellPIMInterMitig Cell Meaning: Indicates whether to enable passive intermodulation (PIM)


Switch Passive interference mitigation in the cell. PIM interference mitigation is
Inter- performed on cells generating intermodulation interference on each
Modulation other if the following conditions are met: (1) This parameter is set to
Interferenc 1; (2) The eNodeB is equipped with an LPMP; (3) Cells are added to
e a PIM interference mitigation cell set. If this parameter is set to 0,
Mitigation PIM interference mitigation is not performed on cells. This parameter
Switch applies only to FDD macro eNodeBs.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: The parameter value ON(On) is
recommended in scenarios with the presence of PIM interference.
The parameter value OFF(Off) is recommended in other scenarios.
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: In scenarios with the
presence of PIM interference, setting this parameter to ON improves
uplink performance and cell throughput.
Applicable Mode: L

PrachJointRecept Prach Joint Meaning: Indicates whether to enable joint reception on the PRACH
ionSwitch Reception in 16T16R LTE TDD networks. If the PrachJointReceptionSwitch
Switch parameter is set to ON, joint reception on the PRACH is enabled. If
the PrachJointReceptionSwitch parameter is set to OFF, joint
reception on the PRACH is disabled. This parameter applies only to
16T16R LTE TDD networks.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If joint reception on the
PRACH is enabled in 16T16R LTE TDD networks, the RACH
access success rate and re-synchronization or RRC connection
reestablishment success rate increase. If joint reception on the
PRACH is disabled in 16T16R coverage-limited networks, the
demodulation performance of the PRACH is poorer than that of the
PUSCH, the access success rate of CEUs decreases.
Applicable Mode: L

FeicicSwitch FeICIC Meaning: Indicates whether to enable the FeICIC algorithm. The
Switch FeICIC algorithm can be disabled and enabled.In a heterogeneous
network (HetNet). If this algorithm is used together with the
appropriate range expansion function of the micro base station and
Dynamic TDM eICIC algorithm,the coverage of micro cells can be
expanded and the number of users absorbed by the micro cells
increased. To support FeICIC algorithm , settings of the EicicSwitch
in macro cells must be the DYNAMIC.
GUI Value Range: OFF(Off), ABS(ABS)
Unit: None
Actual Value Range: OFF, ABS
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship:
-Configuration constraints:
In the CellAlgoSwitch MO, if FeicicSwitch is set to ABS, EicicSwitch
must be set to DYNAMIC.
In the CellAlgoSwitch MO, if the AvoidCDMAInterfSwitch option of
AvoidInterfSwitch is selected, FeicicSwitch must be set to OFF.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: Impact on Radio Network
Performance: When the switch is turned on, the permissible value of
CRE increases, allowing micro base stations to serve more users.
When the switch is turned off, the permissible value of CRE
decreases, allowing micro base stations to serve fewer users. When
the CRE is assigned an appropriate value, macro-to-micro
handovers increase, allowing micro base stations to serve more
users. In this way, user experience is equally improved on macro
and micro networks, improving the edge throughput on the entire
network.
Applicable Mode: L

CamcSwitch Coordinate Meaning: Indicates whether to enable coordinated AMC in the cell.
d AMC This parameter includes the following check boxes:
Switch
UlCamcSw: Indicates whether to enable uplink coordinated AMC in
a cell.
UlInterEnbCamcSw: Indicates whether to enable uplink inter-
eNodeB coordinated AMC in a cell. This check box applies only to
LTE TDD cells.
GUI Value Range: UlCamcSw(UlCamcSw),
UlInterEnbCamcSw(UlInterEnbCamcSw)
Unit: None
Actual Value Range: UlCamcSw, UlInterEnbCamcSw
MML Default Value: None
Recommended Value: UlCamcSw:Off
UlInterEnbCamcSw:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: UlCamcSw:
If this check box is selected, uplink coordinated AMC is used for
uplink MCS selection. Uplink coordinated AMC helps predict
interference and SINR based on the scheduling in the coordinating
cell group, ensuring accurate MCS selection. Selecting this check
box increases cell throughput and UE throughput, improves uplink
coverage and PUSCH coverage, and increases the user-perceivable
rate in scenarios where interference fluctuates. Uplink coordinated
AMC produces higher gains when the interference fluctuates more
violently. Uplink coordinated AMC does not generate gains in
interference-free or steady interference scenarios. If this check box
is deselected, uplink coordinated AMC is not used for uplink MCS
selection, and network performance is not affected.
UlInterEnbCamcSw:
If this check box is selected, uplink inter-eNodeB coordinated AMC
is used for uplink MCS selection. Uplink inter-eNodeB coordinated
AMC helps predict interference and SINR based on the scheduling
in the coordinating cell group, ensuring accurate MCS selection.
Selecting this check box increases cell throughput and UE
throughput, improves uplink coverage and PUSCH coverage, and
increases the user-perceivable rate in scenarios where interference
fluctuates. Uplink inter-eNodeB coordinated AMC produces higher
gains when the interference fluctuates more violently. Uplink inter-
eNodeB coordinated AMC does not generate gains in interference-
free or steady interference scenarios. If this check box is deselected,
uplink inter-eNodeB coordinated AMC is not used for uplink MCS
selection, and network performance is not affected.
Applicable Mode: L

RruUeMapSwitch RU Ue Meaning: Indicates whether to enable MPMU-level UE identification


Map in LampSite eNodeBs. If this parameter is set to ON(On), the
Switch eNodeB generates the mapping between UEs and MPMUs for
MPMU-level maintenance and commissioning based on CHRs and
counters.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
ON, uplink throughput decreases by less than 1%.
Applicable Mode: L

HighSpeedSchO High Meaning: Indicates whether to enable the scheduling optimization


ptSwitch Speed algorithm in highway or high-speed railway scenarios.
Optimized InterfHighSpeedSW: Indicates whether to enable coordinated
Switch scheduling and interference resistance in high-speed railway
scenarios. If this option is selected, coordinated scheduling and
interference resistance in high-speed railway scenarios is enabled
and the eNodeB works with the eCoordinator to perform coordinated
scheduling between public and dedicated networks. If this option is
deselected, coordinated scheduling and interference resistance in
high-speed railway scenarios is disabled. This option applies only to
TDD cells.
HighSpeedUserRedirectSwitch: Indicates whether to redirect high-
speed UEs to high-speed frequencies. This option is selected in a
common cell near the high-speed railway.In other scenarios, it is
recommended that this option be deselected. This option applies
only to TDD cells.
DlAfcSwitch: Indicates whether to enable downlink AFC in a high-
speed cell served by multiple RRUs. The AFC function is valid to the
downlink data, which decreases the performance loss caused by
high-speed mobility. If this option is selected, downlink AFC is
enabled. If this option is deselected, downlink AFC is disabled.
ProcSwitchBasedOnUserSpeed: Indicates whether to enable UE-
speed-based differentiated processing in high-speed railway cells. If
this option is selected, cells support identification of UE speed
attributes and differentiated processing on UE-speed-based
functions and parameters. This parameter applies only to LTE FDD.
SpeedBasedMimoAdpSwitch: Indicates whether to enable UE-
speed-based adaptive MIMO configurations in high-speed railways
cells. If this option is selected, cells support identification of UE
speed attributes and differentiated processing on UE-speed-based
functions and parameters. This option takes effect only when the
ProcSwitchBasedOnUserSpeed option is selected. This parameter
applies only to LTE FDD.
FastAutoFreqControlSwitch: Indicates whether to enable fast uplink
frequency offset compensation for high-speed UEs.
GUI Value Range: InterfHighSpeedSW(InterfHighSpeedSW),
HighSpeedUserRedirectSwitch(HighSpeedUserRedirectSwitch),
DlAfcSwitch(DlAfcSwitch),
ProcSwitchBasedOnUserSpeed(ProcSwitchBasedOnUserSpeed),
SpeedBasedMimoAdpSwitch(SpeedBasedMimoAdpSwitch),
FastAutoFreqControlSwitch(FastAutoFreqControlSwitch)
Unit: None
Actual Value Range: InterfHighSpeedSW,
HighSpeedUserRedirectSwitch, DlAfcSwitch,
ProcSwitchBasedOnUserSpeed, SpeedBasedMimoAdpSwitch,
FastAutoFreqControlSwitch
MML Default Value: None
Recommended Value: It is recommended that the
InterfHighSpeedSW option be selected when the eNodeB is
connected to the eCoordinator and interference coordination for
high-speed railway scenarios is required. It is recommended that
this option be deselected in other scenarios.
It is recommended that the HighSpeedUserRedirectSwitch option be
selected in common cells near the high-speed railway and be
deselected in other scenarios.
It is recommended that the DlAfcSwitch option be selected only in
high-speed railway cell combination scenarios.
It is recommended that the ProcSwitchBasedOnUserSpeed option
be selected in high-speed railway cells serving a large number of
low-speed UEs.
It is recommended that this option be deselected in other scenarios.
It is recommended that the SpeedBasedMimoAdpSwitch option be
selected in high-speed railway cells where closed-loop MIMO is
required for low-speed UEs. It is recommended that this option be
deselected in other scenarios.
FastAutoFreqControlSwitch: Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: Coordinated scheduling and
interference resistance in high-speed railway scenarios applies only
to limited network scenarios. When this function is enabled, PRB
scheduling in nearby common cells is affected and their
performance deteriorates. The severity of the impact depends on the
overlapping bandwidth and the duration for which the train passes
these common cells near the high-speed railway. For the 20 MHz
bandwidth, the performance of the common cell deteriorates by 25%
when the overlapping bandwidth is 5 MHz and deteriorates by 50%
when the overlapping bandwidth is 10 MHz.
If the HighSpeedUserRedirectSwitch option is selected, the eNodeB
may incorrectly consider some UEs that are frequently handed over
as high-speed UEs and then redirect these UEs to high-speed
railway dedicated networks. During the redirection, the throughput
may decrease.
If the DlAfcSwitch option is selected, the downlink performance of
high-speed UEs is improved in high-speed macro cell combination
scenarios. If the DlAfcSwitch option is deselected, the downlink AFC
function is disabled and network performance is not affected.
ProcSwitchBasedOnUserSpeed: If this option is selected, cells
support identification of UE speed attributes and differentiated
processing on UE-speed-based functions and parameters. This
improves user experience on high- and low-speed UEs. If this option
is deselected, differentiated processing is not performed on UE-
speed-based functions or parameters in cells, and user experience
on high- and low-speed UEs is not the optimal.
SpeedBasedMimoAdpSwitch: If this option is selected, closed-loop
MIMO can be configured for low-speed UEs, thereby improving user
experience on low-speed UEs. If this option is deselected,
differentiated processing is not performed on UE-speed-based
functions or parameters in cells, and user experience on low-speed
UEs is not the optimal.
FastAutoFreqControlSwitch: If this option is selected, multiple
processes concurrently handle the uplink automatic frequency offset
control algorithm in high-speed cells and ultra-high speed cells. If
this option is deselected, one process handles the uplink automatic
frequency offset control algorithm at a time in high-speed cells and
ultra-high speed cells.
Applicable Mode: L

ServiceDiffSwitch Service Meaning: Indicates whether to enable the functions related to


Differentiat service differentiation.
ed Switch VideoRateAdaptSwitch: If this option is deselected, adaptive data
rate adjustment for video services is disabled. If this option is
selected, adaptive data rate adjustment for video services is
enabled.
DownLoadRateLimitSwitch: If this option is deselected, download
data rate control during busy hours is disabled. If this option is
selected, download data rate control during busy hours is enabled.
GUI Value Range: VideoRateAdaptSwitch(VideoRateAdaptSwitch),
DownLoadRateLimitSwitch(DownLoadRateLimitSwitch)
Unit: None
Actual Value Range: VideoRateAdaptSwitch,
DownLoadRateLimitSwitch
MML Default Value: None
Recommended Value: VideoRateAdaptSwitch:Off,
DownLoadRateLimitSwitch:Off
Parameter Relationship:
-Configuration constraints:
If the DownLoadRateLimitSwitch or VideoRateAdaptSwitch option of
ServiceDiffSwitch in the CellAlgoSwitch MO is selected, the
ScVideoRateAdaptSwitch option of ScVideoOptSwitch in the
CellAlgoSwitch MO cannot be selected. If the
ScVideoRateAdaptSwitch option is selected, neither
DownLoadRateLimitSwitch nor VideoRateAdaptSwitch can be
selected.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: This parameter controls
whether to adjust video rates or limit download rates during busy
hours.
If the VideoRateAdaptSwitch is turned on, the eNodeB provides a
higher-priority guarantee for video.
When channel conditions are better and video rates are lower than
the guaranteed bit rate, the scheduling probability is higher and cell
throughput is higher.
When channel conditions are poorer and video rates are lower than
the guaranteed bit rate, the scheduling probability is higher and cell
throughput is lower.
If the DownLoadRateLimitSwitch is turned on, the eNodeB provides
a lower-priority guarantee for download services.
When channel conditions are better and download rates are higher
than the maximum bit rate, the scheduling probability is lower and
cell throughput is lower.
When channel conditions are poorer and download rates are higher
than the maximum bit rate, the scheduling probability is lower and
cell throughput is higher.
Applicable Mode: L

LtePttQoSSwitch PTT QoS Meaning: Indicates whether to enable GBR for dedicated bearers
Switch allocated to PTT services. GBR can be enabled for dedicated
bearers allocated to PTT services in a cell only when this parameter
is set to ON(On).
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No
Impact on Radio Network Performance: None
Applicable Mode: L

SrsPucchEnhanc SRS and Meaning: Indicates whether to enable allocation enhancement for
edSwitch PUCCH SRS and PUCCH resources. When this parameter is set to ON,
Allocation allocation enhancement for SRS and PUCCH resources is enabled
Enhanced and inaccurate resource allocation caused by the delay of cell load
Switch update no longer occurs. When this parameter is set to OFF, the
general resource allocation procedure is used and inaccurate
resource allocation caused by the delay of cell load update occurs.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: ON(On)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: When this parameter is set
to ON, inaccurate resource allocation caused by the delay of cell
load update no longer occurs. More long-period resources are
allocated when the cell load changes from light to heavy; more
short-period resources are allocated when the cell load changes
from heavy to light. When this parameter is set to OFF, inaccurate
resource allocation caused by the delay of cell load update occurs.
Applicable Mode: L

UEInactiveTimer UE Meaning: Indicates whether the UeInactiveTimerQci1 parameter


QCI1Switch Inactive takes effect. If UEInactiveTimerQCI1Switch is on,
Timer for UeInactiveTimerQci1 takes effect; when there are QCI 1 services,
QCI1 the UE inactivity timer length is specified by UeInactiveTimerQci1. If
Switch UEInactiveTimerQCI1Switch is off, UeInactiveTimerQci1 does not
take effect and the UE inactivity timer length is specified by
UeInactiveTimer.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If
UEInactiveTimerQCI1Switch is on and the UeInactiveTimerQci1
parameter value is less than the UeInactiveTimer parameter value,
the online time of VoLTE UEs becomes shorter, thereby increasing
the number of RRC connection setup requests and the number of
normal RRC connection releases and decreasing the VoLTE service
drop rate. If UEInactiveTimerQCI1Switch is on and the
UeInactiveTimerQci1 parameter value is greater than the
UeInactiveTimer parameter value, the online time of VoLTE UEs
becomes longer, thereby decreasing the number of RRC connection
setup requests and the number of normal RRC connection releases
and increasing the VoLTE service drop rate.
If UEInactiveTimerQCI1Switch is off, the UEInactiveTimerQCI1
parameter does not take effect. If the UeInactiveTimer parameter is
set to a small value, there is a high probability that a calling UE is
released when the called UE does not answer the call and the UE
inactivity timer expires. Then, the released UE reselects a VoLTE-
incapable cell, causing a call failure.
Applicable Mode: L

UlJRAntNumCom UL JR Meaning: Indicates whether to enable UL joint reception among cells


bSw Antenna each with the specific number of RX antennas. Ul1R1RJRSwitch:
Number Indicates whether to enable UL joint reception among cells each
Combined with one RX antenna. If this option is selected, UL joint reception is
Switch enabled among such cells. You are advised to select this option
when the serving cell and coordinating cells are not connected
based on relaxed backhaul. If this option is deselected, UL joint
reception among such cells is disabled. This option applies only to
LTE FDD. Ul1R2RJRSwitch: Indicates whether to enable UL joint
reception among cells each with one RX antenna and cells each
with two RX antennas. If this option is selected, UL joint reception
among such cells is enabled. You are advised to select this option
when the serving cell and coordinating cells are not connected
based on relaxed backhaul. If this option is deselected, UL joint
reception among such cells is disabled. This option applies only to
LTE FDD. Ul2R8RJRSwitch: Indicates whether to enable UL joint
reception among cells each with two RX antennas and cells each
with eight RX antennas. If this option is selected, UL joint reception
among such cells is enabled. If this option is deselected, UL joint
reception among such cells is disabled. This option applies only to
LTE TDD cells in cell combination scenarios. Ul4R8RJRSwitch:
Indicates whether to enable UL joint reception among cells each
with four RX antennas and cells each with eight RX antennas. If this
option is selected, UL joint reception among such cells is enabled. If
this option is deselected, UL joint reception among such cells is
disabled. This option applies only to LTE TDD. Ul8R8RJRSwitch:
Indicates whether to enable UL joint reception among cells each
with eight RX antennas. If this option is selected, UL joint reception
among such cells is enabled. If this option is deselected, UL joint
reception among such cells is disabled. This option applies only to
LTE TDD. When UL CoMP is enabled or switches related to joint
reception in SFN cells are turned on, UL joint reception among cells
each with two RX antennas and UL joint reception among cells each
with four RX antennas are enabled by default. Ul1R4RJRSwitch:
Indicates whether to enable UL joint reception among cells each
with one RX antenna and cells each with four RX antennas. If this
option is selected, UL joint reception among such cells is enabled.
You are advised to select this option when the serving cell and
coordinating cells are not connected based on relaxed backhaul. If
this option is deselected, UL joint reception among such cells is
disabled. This option applies only to LTE FDD. Ul2R4RJRSwitch:
Indicates whether to enable UL joint reception among cells each
with two RX antennas and cells each with four RX antennas. If this
option is selected, UL joint reception among such cells is enabled.
You are advised to select this option when the serving cell and
coordinating cells are not connected based on relaxed backhaul. If
this option is deselected, UL joint reception among such cells is
disabled. This option applies only to LTE FDD.
GUI Value Range: Ul1R1RJRSwitch(Ul1R1RJRSwitch),
Ul1R2RJRSwitch(Ul1R2RJRSwitch),
Ul2R8RJRSwitch(Ul2R8RJRSwitch),
Ul4R8RJRSwitch(Ul4R8RJRSwitch),
Ul8R8RJRSwitch(Ul8R8RJRSwitch),
Ul1R4RJRSwitch(Ul1R4RJRSwitch),
Ul2R4RJRSwitch(Ul2R4RJRSwitch)
Unit: None
Actual Value Range: Ul1R1RJRSwitch, Ul1R2RJRSwitch,
Ul2R8RJRSwitch, Ul4R8RJRSwitch, Ul8R8RJRSwitch,
Ul1R4RJRSwitch, Ul2R4RJRSwitch
MML Default Value: None
Recommended Value: Ul1R1RJRSwitch:Off,
Ul1R2RJRSwitch:Off,Ul2R8RJRSwitch:Off,Ul4R8RJRSwitch:Off,Ul8
R8RJRSwitch:Off,Ul1R4RJRSwitch:Off,Ul2R4RJRSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: When the Ul1R1RJRSwitch,
Ul1R2RJRSwitch, Ul1R4RJRSwitch, or Ul2R4RJRSwitch option is
selected, UL joint reception among cells with specific number of
antennas is enabled if these cells are not connected in relaxed
backhaul mode, increasing the uplink throughput of UEs in the
overlapping area between these cells and the average uplink cell
throughput. The uplink throughput increase of CEUs indicates the
improvement of uplink coverage performance.
When the Ul2R8RJRSwitch, Ul4R8RJRSwitch, or Ul8R8RJRSwitch
option is selected, UL joint reception among cells with specific
number of antennas is enabled, increasing the uplink throughput of
UEs in the overlapping area between these cells and the average
uplink cell throughput. The uplink throughput increase of CEUs
indicates the improvement of uplink coverage performance.
Applicable Mode: L

VamPhaseShiftAl VAM Meaning: Indicates whether to enable the phase shift algorithm for
goSwitch Phase virtual antenna mapping in four-antenna scenarios with two CRS
Shift ports. This parameter applies only to LTE TDD cells.
Algorithm GUI Value Range:
Switch VamPhaseShiftAlgoSwitch(VamPhaseShiftAlgoSwitch)
Unit: None
Actual Value Range: VamPhaseShiftAlgoSwitch
MML Default Value: None
Recommended Value: VamPhaseShiftAlgoSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: The setting of this
parameter changes the phase of CRS ports for the virtual antenna
mapping algorithm but has no impact on the performance of the
entire network.
Applicable Mode: L

AnrAlgoSwitch ANR Meaning: Indicates whether to enable automatic neighbor relation


Algorithm (ANR). This parameter provides the following options:
Switch BACKWARD_ANR_SW: When intra-RAT event-triggered ANR or
intra-RAT fast ANR is enabled and the BACKWARD_ANR_SW
option is selected for the target cell of an ANR procedure, the cell
can add the source cell to its NCL and NRT after obtaining source
cell information. If BACKWARD_ANR_SW is off, the target cell does
not add the source cell to its NCL or NRT.
INTRA_RAT_OVERDISTANCE_SW: If this option is selected and
intra-RAT neighboring cell classification takes effect in memory
mode, the eNodeB reports information about intra-RAT neighboring
cells to the U2000 for the U2000 to detect ultra-distance neighboring
cells and handles the detection result returned by the U2000. If this
option is deselected, the eNodeB does not report information about
intra-RAT neighboring cells to the U2000 or handle the ultra-
distance neighboring cell detection result returned by the U2000.
UTRAN_OVERDISTANCE_SW: If this option is selected and
neighboring UTRAN cell classification takes effect, the eNodeB
reports information about neighboring UTRAN cells to the U2000 for
the U2000 to detect ultra-distance neighboring cells and handles the
detection result returned by the U2000. If this option is deselected,
the eNodeB does not report information about neighboring UTRAN
cells to the U2000 or handle the ultra-distance UTRAN neighboring
cell detection result returned by the U2000.
GUI Value Range:
BACKWARD_ANR_SW(BACKWARD_ANR_SW),
INTRA_RAT_OVERDISTANCE_SW(INTRA_RAT_OVERDISTANC
E_SW),
UTRAN_OVERDISTANCE_SW(UTRAN_OVERDISTANCE_SW)
Unit: None
Actual Value Range: BACKWARD_ANR_SW,
INTRA_RAT_OVERDISTANCE_SW,
UTRAN_OVERDISTANCE_SW
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If BACKWARD_ANR_SW is
deselected, addition of neighbor relationships by backward ANR
does not take effect, preventing the addition of redundant neighbor
relationships and PCI confusion. However, the efficiency of adding
unknown neighbor relationships decreases, reducing the handover
success rate and increasing the service drop rate in the case of PCI
confusion between neighboring cells. If BACKWARD_ANR_SW is
selected, addition of neighbor relationships by backward ANR takes
effect and unknown neighbor relationships can be added promptly.
However, redundant neighbor relationships may also be added and
confused neighboring cell PCI configurations may be introduced,
reducing the handover success rate and increasing the service drop
rate in the case of CGI reading failure before handovers.
If INTRA_RAT_OVERDISTANCE_SW is selected, the eNodeB
identifies intra-RAT over-distant neighboring cells and does not hand
over UEs to such cells, reducing handover failures and increasing
intra-RAT handover success rate. If
INTRA_RAT_OVERDISTANCE_SW is deselected, the eNodeB may
hand over UEs to over-distant neighboring cells, causing handover
failures.
If UTRAN_OVERDISTANCE_SW is selected, the eNodeB identifies
over-distant UTRAN neighboring cells and does not hand over UEs
to such cells, reducing handover failures and increasing the success
rate of handovers to UTRAN neighboring cells. If
UTRAN_OVERDISTANCE_SW is deselected, the eNodeB may
hand over UEs to over-distant UTRAN neighboring cells, causing
handover failures.
Applicable Mode: L

Dl256QamAlgoS Downlink Meaning: Indicates whether to enable the downlink 256QAM


witch 256QAM algorithm.
Algorithm Dl256QamSwitch: If this option is selected, downlink 256QAM takes
Switch effect, and the maximum downlink modulation mode is 256QAM for
UEs that support 256QAM. If this option is deselected, downlink
256QAM does not effect and the maximum downlink modulation
mode is 64QAM. This feature takes effect only when a UBBP board
is configured.
GUI Value Range: Dl256QamSwitch(Dl256QamSwitch)
Unit: None
Actual Value Range: Dl256QamSwitch
MML Default Value: None
Recommended Value: Dl256QamSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: Dl256QamSwitch: If this
option is selected, the throughput and spectral efficiency of
256QAM-capable UEs at the cell center are improved and data
transmission delay is reduced. Deselecting this option has no impact
on network performance.
Applicable Mode: L

MlbAutoGroupSw MLB Auto Meaning: OverlapIndAutoSwitch: Indicates whether the serving cell
itch Group evaluates its coverage overlap with neighboring cells and adds or
Configurati removes coverage overlap flags for the neighboring cells. The
on Switch serving cell performs these actions only when this option is selected.
The settings of MicroOverlapIndSwitch and
MicroGroupOverlapIndSwitch take effect only when the
OverlapIndAutoSwitch option is selected.
MicroOverlapIndSwitch: Indicates whether a micro cell evaluates its
coverage overlap with the associated macro cell and instructs the
macro cell to add or remove the coverage overlap flag for the micro
cell. The micro cell performs these actions only when this option is
selected. If OverlapIndAutoSwitch and MicroOverlapIndSwitch both
are selected for a macro cell, the macro cell adds or removes the
coverage overlap flag for a micro cell when instructed to do so by
the micro cell.
MicroGroupOverlapIndSwitch: Indicates whether a macro cell
evaluates its coverage overlap with a group of associated micro
cells and adds or removes coverage overlap flags for all micro cells
in the group. The macro cell performs these actions only when this
option is selected. This option applies only to macro cells. If both
MicroOverlapIndSwitch and MicroGroupOverlapIndSwitch are
selected for a macro cell, only MicroOverlapIndSwitch takes effect.
GUI Value Range: OverlapIndAutoSwitch(OverlapIndAutoSwitch),
MicroOverlapIndSwitch(MicroOverlapIndSwitch),
MicroGroupOverlapIndSwitch(MicroGroupOverlapIndSwitch)
Unit: None
Actual Value Range: OverlapIndAutoSwitch,
MicroOverlapIndSwitch, MicroGroupOverlapIndSwitch
MML Default Value: None
Recommended Value: OverlapIndAutoSwitch:On
MicroOverlapIndSwitch:Off
MicroGroupOverlapIndSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

CaAutoGroupSwi CA Auto Meaning: Indicates whether to enable automatic grouping for carrier
tch Group aggregation. If automatic grouping is enabled, the eNodeB identifies
Configurati the proportion of overlap between serving and inter-frequency
on Switch neighboring cells and automatically sets, modifies, or clears the
blind SCell configuration flag for the neighboring cell.
GUI Value Range: BlindScellAutoSwitch(BlindScellAutoSwitch)
Unit: None
Actual Value Range: BlindScellAutoSwitch
MML Default Value: None
Recommended Value: BlindScellAutoSwitch:On
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

AttachCellSelfCfg Attach Cell Meaning: Indicates whether to enable automatic configuration of


Switch Auto macro-micro associations. If this parameter is set to ON, a micro cell
Config performs measurements to determine the associated macro cell.
Switch The macro-micro association is updated at the specified time. If this
parameter is set to OFF, macro-micro associations cannot be
automatically configured. Automatic configuration of macro-micro
associations requires that this parameter be set to ON for all macro
and micro cells involved.This parameter applies only to LTE FDD.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If the macro-micro
association is automatically updated for a micro cell and the
previous and new macro cells use different ABS settings, the micro
cell does not initiate CRE and measurement set reconfiguration for
UEs that accessed the micro cell before the update. (The purpose is
to control RRC signaling overheads.) These UEs may suffer
stronger interference from the previous macro cell, and their
performance deteriorates. It is recommended that macro-micro
associations be automatically updated only when the micro cell
serves few UEs.
Applicable Mode: L

CellDlCoverEnha Downlink Meaning: Indicates whether to enable cell coverage enhancement.


nceSwitch Cell Turning on this switch can increase the throughput of cell edge
Coverage users and improve cell coverage.
Enhancem GUI Value Range:
ent Switch DlCellCoverEnhanceAlgoSw(DlCellCoverEnhanceAlgoSw)
Unit: None
Actual Value Range: DlCellCoverEnhanceAlgoSw
MML Default Value: None
Recommended Value: DlCellCoverEnhanceAlgoSw:off
Parameter Relationship:
-Configuration constraints:
The DlCellCoverEnhanceAlgoSw option of
CellDlCoverEnhanceSwitch in the CellAlgoSwitch MO can be
selected only if GLPwrShare of the CellAlgoSwitch MO is set to
OFF.
In the CellAlgoSwitch MO, if the Virtual4T4RSwitch option of
EmimoSwitch is selected, the DlCellCoverEnhanceAlgoSw option of
CellDlCoverEnhanceSwitch must be deselected.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance:
DlCellCoverEnhanceAlgoSw: If this option is selected, cell coverage
enhancement is enabled to increase downlink transmit power based
on RRU capability for UEs that meet a specific MCS threshold. In
wide or intensive coverage scenarios, this function increases the
throughput of cell edge users and improves cell coverage. If this
option is deselected, cell coverage enhancement is disabled and
network performance is not affected.
Applicable Mode: L

UlSchExtSwitch Uplink Meaning: Indicates whether to enable or disable extended functions


Schedule of uplink scheduling. UlPacketLenAwareSchSw: Indicates whether
Extended to enable the optimization of packet length awareness performance.
Switch If this option is selected, the optimization of packet length
awareness performance is enabled in the uplink. If this option is
deselected, packet length awareness performance optimization is
disabled in the uplink. EnhExtQCITtiBundlingSwitch: Indicates
whether to enable TTI bundling for QCI 65, QCI 66, or enhanced
extended QCIs of push-to-talk (PTT) services. If this option is
selected, the number of transmission opportunities increases within
the air interface delay budget of PTT services, and uplink coverage
is improved. EnhExtQCISpsSchSwitch: Indicates whether to enable
semi-persistent scheduling during talk spurts of PTT services with
QCI 65, QCI 66, or enhanced extended QCIs. If this option is
selected, semi-persistent scheduling is applied. If this option is
deselected, dynamic scheduling is applied. UlVoipRbRsvSwitch:
Indicates whether to reserve PUSCH RBs for UEs running voice
services in the uplink. If this option is selected, PUSCH RBs are
reserved for UEs running voice services in the uplink. If this option is
deselected, PUSCH RBs are not reserved for UEs running voice
services in the uplink. This switch applies only to LTE FDD cells.
This function does not take effect if the uplink cell bandwidth is less
than 5 MHz. UlThpEnhSwitch: Indicates whether to enhance the
uplink throughput improvement function. If this option is selected,
the PUCCH overhead used during uplink scheduling is calculated
based on the number of RBs actually used by the PUCCH when
only a few online UEs exist in the cell. This improves the uplink
throughput when there are only a few UEs. If this option is
deselected, the PUCCH overhead used during uplink scheduling is
calculated based on the number of currently configured PUCCH
RBs. This parameter applies only to LTE TDD cells.
UlDataFitterRbCalcSwitch: Indicates whether to enable the
algorithm of RB calculation based on uplink data volume matching.
The algorithm takes effect only when this option and the
SchedulerCtrlPowerSwitch option of the UlSchSwitch parameter are
selected. When this algorithm takes effect, the number of required
RBs is estimated based on the UE capability and the data volume to
be scheduled. If this algorithm does not take effect, the number of
required RBs is estimated based on the UE spectral efficiency and
the data volume to be scheduled. UlFssOptForAttach: Indicates
whether to perform uplink frequency selective scheduling based on
the value of Interf in the network entry phase. If this option is
selected, uplink frequency selective scheduling based on the value
of Interf is performed in the network entry phase. If this option is
deselected, frequency selective scheduling based on the SINR is
performed in the network entry phase. This parameter needs to be
enabled when the check box of ULFSSAlgoSwitch is selected. This
parameter applies only to LTE TDD cells. SrbProbeSchSwitch:
Indicates whether to proactively schedule uplink signaling. If this
option is selected, when the eNodeB determines that data correctly
scheduled in the downlink is control-plane signaling that requires the
uplink signaling feedback and does not receive the feedback within
a specified period of time, the eNodeB triggers proactive uplink
scheduling once. UlSchCtrlPwrUserSetOptSw: Indicates whether to
enable the algorithm of selecting UE sets during power control
restrictions considered (for scheduling) by the scheduler. This
algorithm takes effect only when this option and the
SchedulerCtrlPowerSwitch option of the UlSchSwitch parameter are
selected. When this algorithm takes effect, pre-scheduled UEs of a
lower priority are not included in the UE set selected by the
scheduler. When this algorithm does not take effect, all pre-
scheduled UEs are included in the UE set selected by the scheduler.
UlPttSchOptSwitch: Indicates whether to enable dynamic scheduling
for PTT services with QCI 65, QCI 66, or enhanced extended QCIs.
If this option is selected, for PTT service UEs that are scheduled
dynamically in the uplink, the eNodeB triggers uplink dynamic
scheduling when the scheduling interval is greater than the uplink
voice scheduling interval threshold. This ensures that voice service
UEs are scheduled timely in the uplink and packets are not lost due
to the expiration of the PDCP packet discard timer in heavy traffic
scenarios. If this option is deselected, the function does not take
effect. UlPttDataSizeEstSwitch: Indicates whether to estimate uplink
traffic volume for dynamic scheduling of PTT services with QCI 65,
QCI 66, or enhanced extended QCIs. If this option is selected, the
eNodeB estimates uplink traffic volume for dynamic scheduling of
PTT services, reducing the packet delay and packet loss rate and
increasing voice quality of PTT services. If this option is deselected,
the function does not take effect.
GUI Value Range:
UlPacketLenAwareSchSw(UlPacketLenAwareSchSw),
EnhExtQCITtiBundlingSwitch(EnhExtQCITtiBundlingSwitch),
EnhExtQCISpsSchSwitch(EnhExtQCISpsSchSwitch),
UlVoipRbRsvSwitch(UlVoipRbRsvSwitch),
UlThpEnhSwitch(UlThpEnhSwitch),
UlDataFitterRbCalcSwitch(UlDataFitterRbCalcSwitch),
UlFssOptForAttach(UlFssOptForAttach),
SrbProbeSchSwitch(SrbProbeSchSwitch),
UlSchCtrlPwrUserSetOptSw(UlSchCtrlPwrUserSetOptSw),
UlPttSchOptSwitch(UlPttSchOptSwitch),
UlPttDataSizeEstSwitch(UlPttDataSizeEstSwitch)
Unit: None
Actual Value Range: UlPacketLenAwareSchSw,
EnhExtQCITtiBundlingSwitch, EnhExtQCISpsSchSwitch,
UlVoipRbRsvSwitch, UlThpEnhSwitch, UlDataFitterRbCalcSwitch,
UlFssOptForAttach, SrbProbeSchSwitch,
UlSchCtrlPwrUserSetOptSw, UlPttSchOptSwitch,
UlPttDataSizeEstSwitch
MML Default Value: None
Recommended Value: UlPacketLenAwareSchSw:Off,
EnhExtQCITtiBundlingSwitch:Off, EnhExtQCISpsSchSwitch:Off,
UlVoipRbRsvSwitch:Off, UlThpEnhSwitch:Off,
UlDataFitterRbCalcSwitch:Off, UlSchCtrlPwrUserSetOptSw:Off,
SrbProbeSchSwitch: Set this switch on when the RRC connection
setup and E-RAB setup success rates need to be increased and the
service drop rate needs to be decreased on the live network. Set
this switch off if the RRC connection setup success rate, E-RAB
setup success rate, and service drop rate are normal.
UlFssOptForAttach:On.
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: ULPacketLenAwareSchSw:
If this option is selected, packet length awareness performance
optimization in the uplink is enabled, improving the UE-perceivable
throughput in the uplink in medium- and high-load cells. If this option
is deselected, the function does not take effect, and network KPIs
are not affected.
EnhExtQCITtiBundlingSwitch: If this option is selected, PUSCH
transmission at the cell edge improves when the channel quality for
PTT service UEs is poor and the TX power is limited.
EnhExtQCISpsSchSwitch: If this option is selected, the eNodeB
performs semi-persistent scheduling on PTT services with
standardized QCI 65 or 66, and PDCCH resource overhead and
CQI reporting overhead decrease, which increases the PTT UE
capacity in unicast mode. If this option is deselected, the eNodeB
performs dynamic scheduling on PTT services with standardized
QCI 65 or 66, and PDCCH resource overhead increases. As a
result, the PTT UE capacity decreases in unicast mode, but the QoS
of PTT services improves.
UlVoipRbRsvSwitch: If this option is selected, the packet loss rate
and RBLER in the uplink of UEs running voice services decrease.
However, throughput decreases, uplink interference increases and
the access performance as well as service drop performance
deteriorate slightly on UEs that are not running voice services, and
the average UE data rate decreases. If this option is deselected, the
network performance is not affected.
UlThpEnhSwitch: If this option is selected, the uplink throughput
increases when only a few online UEs exist in the cell. If this option
is deselected, the network performance is not affected.
UlDataFitterRbCalcSwitch: If this option and the
SchedulerCtrlPowerSwitch option of the UlSchSwitch parameter are
selected, the algorithm of RB calculation based on uplink data
volume matching takes effect. In this way, cell capacity and the UE-
perceived throughput increase when the network is heavily loaded in
the uplink. If this option is deselected, the algorithm does not take
effect, and the network performance is not affected.
UlFssOptForAttach: If this option is selected, uplink frequency
selective scheduling is performed based on the value of Interf in the
network entry phase. As a result, more frequency selective
scheduling gains are obtained and the RRC connection setup
success rate and E-RAB setup success rate increase. If this option
is deselected, uplink frequency selective scheduling is performed
based on the SINR in the network entry phase. Due to insufficient
SINR measurement in the network entry phase, the measurement
results cannot reflect the signal quality of the whole bandwidth. The
frequency selective scheduling gains are smaller. The RRC
connection setup success rate and E-RAB setup success rate are
lower than those achieved when this option is selected.
SrbProbeSchSwitch: If this option is selected, uplink scheduling of
control-plane signaling can be guaranteed. In addition, the RRC
connection setup success rate, E-RAB setup success rate, and
service drop rate are ensured. If this option is deselected, the
network performance is not affected.
UlSchCtrlPwrUserSetOptSw: If this option and the
SchedulerCtrlPowerSwitch option of the UlSchSwitch parameter are
selected, the resources consumed by pre-scheduled UEs are
reduced in scenarios where the uplink PRB usage is high, improving
the cell throughput and UE-perceived throughput. If this option is
deselected, the function does not take effect, and the network
performance is not affected.
UlPttSchOptSwitch: If this option is selected, an uplink dynamic
scheduling attempt is triggered for PTT UEs adopting uplink
dynamic scheduling when the scheduling interval is greater than the
uplink scheduling interval threshold for voice services. This ensures
timely uplink scheduling on PTT UEs even when missing detections
of SRs occur, thereby avoiding packet loss caused by the expiration
of the PDCP packet discarding timer.
UlPttDataSizeEstSwitch: If this option is selected, traffic volume
estimation on dynamically scheduled uplink PTT services is
enabled. As a result, the packet delay and packet loss rate of PTT
services decrease, and PTT service quality improves. However, the
number of RBs and that of CCEs consumed by UEs running PTT
services increase, and therefore the cell throughput and UE
throughput decrease.
Applicable Mode: L

UdcAlgoSwitch UL Data Meaning: Indicates whether to enable the uplink data compression
Compressi algorithm in a cell.
on BasicUdcSwitch: Indicates whether to enable the uplink Qualcomm
Algorithm data compression algorithm in a cell. If this option is selected, uplink
Switch Qualcomm data compression is enabled. If this option is deselected,
uplink Qualcomm data compression is disabled.
GUI Value Range: BasicUdcSwitch(BasicUdcSwitch)
Unit: None
Actual Value Range: BasicUdcSwitch
MML Default Value: None
Recommended Value: BasicUdcSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this option is selected,
uplink data compression is enabled. In this case, if the number of
uplink data compression-capable UEs and that of web browsing
services account for a large portion in a cell, the uplink data rate of
UEs greatly increases.
Applicable Mode: L

VoLTESwitch VoLTE Meaning: Indicates whether to enable VoLTE-related algorithms.


Switch AcBarForVoLTEPreferSwitch: Indicates whether to allow preferential
accesses for UEs initiating VoLTE services during access class
control. If this option is selected, voice preference information is
included in SIB2 to ensure that access class control does not apply
to UEs initiating MMTEL voice services, MMTEL video services, IP-
based short message services, or short message services based on
the setting of the VoLTEPreferCfgInd parameter in the CellAcBar
MO. If this option is deselected, voice preference information is not
included in SIB2, and access class control applies to UEs initiating
MMTEL voice services, MMTEL video services, IP-based short
message services, or short message services.
GUI Value Range:
AcBarForVoLTEPreferSwitch(AcBarForVoLTEPreferSwitch)
Unit: None
Actual Value Range: AcBarForVoLTEPreferSwitch
MML Default Value: None
Recommended Value: AcBarForVoLTEPreferSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance:
AcBarForVoLTEPreferSwitch: If this option is selected, access class
control does not apply to UEs initiating MMTEL voice services,
MMTEL video services, IP-based short message services, or short
message services based on the setting of the VoLTEPreferCfgInd
parameter in the CellAcBar MO, improving user experience of these
UEs. If this option is deselected, access class control applies to UEs
initiating MMTEL voice services, MMTEL video services, IP-based
short message services, and short message services, affecting user
experience of these UEs.
Applicable Mode: L

VoipFailDecSelfR VoIP Meaning: Indicates whether to enable self-rectification on voice


ecSwitch Decryption decryption failures. When voice decryption fails due to disordered
Failure PDCP SNs, enabling this function allows detection and self-
Self rectification on voice decryption failures, and disabling this function
Recovery does not allow detection and self-rectification on voice decryption
Switch failures.
GUI Value Range:
VoipFailDecSelfRecSwitch(VoipFailDecSelfRecSwitch)
Unit: None
Actual Value Range: VoipFailDecSelfRecSwitch
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification: No
Impact on Radio Network Performance: Selecting this option
improves the poor voice quality (such as one-way audio) due to
voice decryption failures.
Applicable Mode: L

DeprioritisationD Deprioritis Meaning: Indicates whether the RRCConnectionReject message


eliverInd ation includes the IE deprioritisationReq and the setting of the IE
Deliver deprioritisationType in the message. If this parameter is set to
Indicator UNDELIVER(UNDELIVER), the RRCConnectionReject message
does not include the IE deprioritisationReq. If this parameter is set to
FREQUENCY(FREQUENCY), the RRCConnectionReject message
includes the IE deprioritisationReq and the value of the IE
deprioritisationType is FREQUENCY. In this case, after the UE
receives an RRCConnectionReject message, the lowest cell
reselection priority is configured for the serving frequency and the
frequencies contained in the RRCConnectionReject messages that
have been received and include the IE deprioritisationReq. If this
parameter is set to EUTRA(EUTRA), the RRCConnectionReject
message includes the IE deprioritisationReq and the value of the IE
deprioritisationType is EUTRA. In this case, after the UE receives an
RRCConnectionReject message, the lowest cell reselection priority
is configured for all E-UTRAN frequencies. For details about the IEs,
see 3GPP 36.331.
GUI Value Range: UNDELIVER(UNDELIVER),
FREQUENCY(FREQUENCY), EUTRA(EUTRA)
Unit: None
Actual Value Range: UNDELIVER, FREQUENCY, EUTRA
MML Default Value: None
Recommended Value: UNDELIVER(UNDELIVER)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
UNDELIVER, the IE deprioritisationReq is not delivered, and the
UEs that are not allowed to set up RRC connections still camp on
the serving frequency and attempt to reaccess the cell after the
timer T302 expires. If this parameter is set to FREQUENCY, UEs
that are not allowed to set up RRC connections attempt to reselect
other frequencies. In this way, network congestion can be relieved
and user experience can be improved if resources are available on
other frequencies. If this parameter is set to EUTRA, UEs that are
not allowed to set up RRC connections attempt to reselect other
RATs. In this way, network congestion can be relieved and user
experience can be improved if resources are available on other
RATs.
Applicable Mode: L

CmasSwitch Cmas Meaning: Indicates whether to enable commercial mobile alert


Switch system (CMAS).
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

MFBIAlgoSwitch MFBI Meaning: Indicates whether to enable MFBI-related algorithms. The


Algorithm MFBIBandAdjAlgoSwitch option indicates whether to enable MFBI
Switch band priority adjustment. If this option is selected, MFBI band priority
adjustment is enabled. If this option is deselected, MFBI band
priority adjustment is disabled.
GUI Value Range:
MFBIBandAdjAlgoSwitch(MFBIBandAdjAlgoSwitch)
Unit: None
Actual Value Range: MFBIBandAdjAlgoSwitch
MML Default Value: None
Recommended Value: MFBIBandAdjAlgoSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

PciConflictReport PCI Meaning: Indicates whether the eNodeB reports physical cell
Switch Conflict identifier (PCI) conflicts to the U2000.
Report COLLISION_REPORT_SW: If this option is selected, check results
Switch about whether PCI collisions occur between the local cell and other
intra-eNodeB cells or between the local cell and external cells are
reported to the U2000. If this option is deselected, the check results
are not reported to the U2000. For details about PCI collisions, see
3GPP TS 36.902.
CONFUSION_REPORT_SW: If this option is selected, check results
about whether PCI confusions occur between candidate target
neighboring cells whose neighbor relationships with the local cell are
recorded in the NRTs are reported to the U2000. If this option is
deselected, the check results are not reported to the U2000. For
details about PCI confusion, see 3GPP TS 36.902.
GUI Value Range:
COLLISION_REPORT_SWITCH(COLLISION_REPORT_SWITCH),
CONFUSION_REPORT_SWITCH(CONFUSION_REPORT_SWITC
H)
Unit: None
Actual Value Range: COLLISION_REPORT_SWITCH,
CONFUSION_REPORT_SWITCH
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance:
COLLISION_REPORT_SWITCH: If this option is selected and PCI
collisions occur, information about PCI collisions is displayed on the
PCI Self-Optimization page on the U2000. If the RRUs are installed
remotely, PCI collisions may be falsely detected. If this option is
deselected, information about PCI collisions is not displayed on the
PCI Self-Optimization page on the U2000.
CONFUSION_REPORT_SWITCH: If this option is selected and PCI
confusions occur, information about PCI confusions is displayed on
the PCI Self-Optimization page on the U2000. If this option is
deselected, information about PCI confusions is not displayed on the
PCI Self-Optimization page on the U2000.
Applicable Mode: L

MroSwitch MRO Meaning: Indicates the options for mobility robustness optimization
algorithm (MRO) algorithms.
switch IntraFreqMroSwitch: If this option is selected, the eNodeB
dynamically adjusts the intra-frequency handover parameters to
increase the intra-frequency handover success rate. If this option is
deselected, the adjustment is not performed.
InterFreqMroSwitch: If this option is selected, the eNodeB
dynamically adjusts the inter-frequency handover parameters to
increase the inter-frequency handover success rate. If this option is
deselected, the adjustment is not performed.
UtranMroSwitch: If this option is selected, the eNodeB dynamically
adjusts the UTRAN handover parameters to increase the success
rate of handovers to UTRAN. If this option is deselected, the
adjustment is not performed.
GeranMroSwitch: If this option is selected, the eNodeB dynamically
adjusts the GERAN handover parameters to increase the success
rate of handovers to GERAN. If this option is deselected, the
adjustment is not performed.
UEMroSwitch: If this option is selected, the eNodeB dynamically
adjusts the UE-level handover parameters to decrease the number
of ping-pong handovers, thereby increasing the UEs' handover
success rate. If this option is deselected, the adjustment is not
performed. In this version, the function of preventing ping-pong
handovers in the UE-level MRO algorithm takes effect only in intra-
frequency handover scenarios.
IntraFreqReselOptSwitch: If this option is selected, the eNodeB
dynamically adjusts intra-frequency cell reselection parameters,
which reduces the number of unnecessary handovers and ensures a
steady handover success rate. If this option is deselected, the
eNodeB does not adjust intra-frequency cell reselection parameters.
UtranUnnecHoOptSwitch: If this option is selected, the eNodeB
dynamically adjusts parameters about handovers from E-UTRAN to
UTRAN to reduce the number of unnecessary handovers from E-
UTRAN to UTRAN, increase the probability that UEs camp in LTE
networks, and improve user experience. If this option is deselected,
the eNodeB does not perform the adjustment. For LTE FDD, this
option takes effect only when the UnnecHoOptWithoutRIM option is
deselected.
GeranUnnecHoOptSwitch: If this option is selected, the eNodeB
dynamically adjusts parameters about handovers from E-UTRAN to
GERAN to reduce the number of unnecessary handovers from E-
UTRAN to GERAN, increase the probability that UEs camp in LTE
networks, and improve user experience. If this option is deselected,
the eNodeB does not perform the adjustment. In the current version,
this option applies only to LTE TDD.
IntraRatCallbackSwitch: If this option is selected, after handover
parameters are optimized in intra- or inter-frequency neighboring
cells, the eNodeB monitors the ratio of abnormal handovers within
an MRO period for the neighboring cells. If the ratio increases, the
eNodeB rolls back the parameter settings. If this option is
deselected, the eNodeB does not perform the monitoring or the
parameter setting rollback. In the current version, this option applies
only to LTE TDD.
UnnecHoOptWithoutRIM: If this option is selected, the eNodeB uses
a Huawei proprietary non-RIM-based solution to reduce the number
of unnecessary inter-RAT handovers. If this option is deselected, the
eNodeB uses the protocol-defined RIM-based solution to reduce the
number of unnecessary inter-RAT handovers. LTE FDD supports
only the protocol-defined scheme with RIM.
GUI Value Range: IntraFreqMroSwitch(IntraFreqMroAlgoSwitch),
InterFreqMroSwitch(InterFreqMroAlgoSwitch),
UtranMroSwitch(UtranMroSwitch),
GeranMroSwitch(GeranMroSwitch),
UEMroSwitch(UeMroAlgoSwitch),
IntraFreqReselOptSwitch(IntraFreqReselOptSwitch),
UtranUnnecHoOptSwitch(UtranUnnecHoOptSwitch),
GeranUnnecHoOptSwitch(GeranUnnecHoOptSwitch),
IntraRatCallbackSwitch(IntraRatCallbackSwitch),
UnnecHoOptWithoutRIM(UnnecHoOptWithoutRIM)
Unit: None
Actual Value Range: IntraFreqMroSwitch, InterFreqMroSwitch,
UtranMroSwitch, GeranMroSwitch, UEMroSwitch,
IntraFreqReselOptSwitch, UtranUnnecHoOptSwitch,
GeranUnnecHoOptSwitch, IntraRatCallbackSwitch,
UnnecHoOptWithoutRIM
MML Default Value: None
Recommended Value: IntraFreqMroAlgoSwitch:Off,
InterFreqMroAlgoSwitch:Off, UtranMroSwitch:Off,
GeranMroSwitch:Off, UeMroAlgoSwitch:Off,
IntraFreqReselOptSwitch:Off, UtranUnnecHoOptSwitch:Off,
GeranUnnecHoOptSwitch:Off, IntraRatCallbackSwtich:Off,
UnnecHoOptWithoutRIM:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: IntraFreqMroSwitch: If this
option is selected, intra-frequency handover parameters are
optimized, the number of abnormal intra-frequency handovers
decreases. MRO against delayed intra-frequency handovers
increases the number of handovers and the probability of handovers
being triggered. MRO against premature and ping-pong intra-
frequency handovers decreases the number of handovers and the
probability of handovers being triggered.
InterFreqMroSwitch: If this option is selected, inter-frequency
handover parameters are optimized, the number of abnormal inter-
frequency handovers decreases. MRO against delayed inter-
frequency handovers increases the number of handovers and the
probability of handovers being triggered. MRO against premature
and ping-pong inter-frequency handovers decreases the number of
handovers and the probability of handovers being triggered.
UtranMroSwitch: If this option is selected, parameters related to
inter-RAT handovers to UTRAN are optimized, the number of
abnormal handovers from E-UTRAN to UTRAN decreases. MRO
against delayed inter-RAT handovers to UTRAN increases the
number of handovers and the probability of handovers being
triggered. MRO against premature inter-RAT handovers to UTRAN
decreases the number of handovers and the probability of
handovers being triggered.
GeranMroSwitch: If this option is selected, parameters related to
inter-RAT handovers to GERAN are optimized, the number of
abnormal handovers from E-UTRAN to GERAN decreases. MRO
against delayed inter-RAT handovers to GERAN increases the
number of handovers and the probability of handovers being
triggered. MRO against premature inter-RAT handovers to GERAN
decreases the number of handovers and the probability of
handovers being triggered.
UEMroSwitch: If this option is selected, parameters related to intra-
frequency handovers are optimized, the number of ping-pong
handovers and the number of unnecessary handovers decrease;
however, the probability of triggering handovers also decreases.
IntraFreqReselOptSwitch: If this option is selected, parameters
related to intra-frequency reselection are dynamically checked and
optimized when parameters related to intra-frequency handovers are
adjusted, reducing the number of unnecessary handovers caused by
inconsistent settings between parameters related to intra-frequency
handovers and parameters related to intra-frequency reselection
and maintaining a stable handover success rate.
UtranUnnecHoOptSwitch: If this option is selected, MRO against
unnecessary inter-RAT handovers to UTRAN can be performed,
thereby increasing the probability that UEs camp in LTE networks
and improving user experience. However, the inter-RAT handovers
to UTRAN success rate and the service drop rate may be affected. If
this option is deselected, MRO against unnecessary inter-RAT
handovers to UTRAN cannot be performed, and KPIs are not
negatively affected.
GeranUnnecHoOptSwitch: If this option is selected, MRO against
unnecessary inter-RAT handovers to GERAN can be performed,
thereby increasing the probability that UEs camp in LTE networks
and improving user experience. However, the inter-RAT handovers
to GERAN success rate and the service drop rate may be affected.
If this option is deselected, MRO against unnecessary inter-RAT
handovers to GERAN cannot be performed, and KPIs are not
negatively affected.
IntraRatCallbackSwitch: If this option is selected, after handover
parameters are optimized in intra- or inter-frequency neighboring
cells, the eNodeB monitors performance within the next MRO period
for the neighboring cells. If performance deteriorates, the eNodeB
rolls back the parameter settings. If this option is deselected, the
eNodeB does not perform the monitoring or the parameter setting
rollback.
Applicable Mode: L

OpResourceGrou Operator Meaning: Indicates whether to enable RAN sharing so that


pShareSwitch Resource admission and scheduling take effect in RAN sharing mode. When
Group the switch is on, operators share the resources specified by the
Share RAN-sharing operator group. When the OpPrbGroupshareSwitch
Switch option is selected, PRB resources can be shared by operator group.
This parameter applies only to LTE FDD cells.
GUI Value Range:
OpPrbGroupshareSwitch(OpPrbGroupshareSwitch)
Unit: None
Actual Value Range: OpPrbGroupshareSwitch
MML Default Value: None
Recommended Value: OpPrbGroupshareSwitch:Off
Parameter Relationship:
-Configuration constraints:
When the OpPrbGroupshareSwitch option of
OpResourceGroupShareSwitch in the CellAlgoSwitch MO is
selected, OpResourceGroupIndex in related CellOp MOs cannot be
set to 255.
Service Interrupted After Modification: Yes
Impact on Radio Network Performance: None
Applicable Mode: L

CellRecoverySwit Cell Meaning: NoUserCellRecoverySwitch: This option controls whether


ch Recovery the eNodeB detects a cell serves UEs when reestablishing the cell.
Switch If this option is selected, the eNodeB does not check whether a cell
serves UEs and performs cell reestablishment directly to improve
cell specifications. If this option is deselected, the eNodeB performs
cell reestablishment to improve cell specifications when the cell
does not serve UEs.
GUI Value Range:
NoUserCellRecoverySwitch(NoUserCellRecoverySwitch)
Unit: None
Actual Value Range: NoUserCellRecoverySwitch
MML Default Value: None
Recommended Value: NoUserCellRecoverySwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: NoUserCellRecoverySwitch:
If this option is selected and the service capability of a cell recovers,
the eNodeB performs cell reestablishment directly to improve cell
specifications even if the cell serves RRC_CONNECTED UEs. If this
option is deselected and the service capability of a cell recovers, the
cell is deactivated and reestablished when the cell does not serve
RRC_CONNECTED UEs.
Applicable Mode: L

EnhancedMlbAlg Enhanced Meaning: Indicates whether to enable MLB algorithm enhancement.


oSwitch MLB This parameter provides the following options:
Algorithm SpectralEffBasedLoadEvalSw: If this option is deselected, the
Switch spectral efficiency difference is not considered during inter-
frequency cell load comparison for user-number-based inter-
frequency MLB. If this option is selected, the difference is
considered in the preceding scenario, and cells with high spectral
efficiency carry more traffic.
VideoSrvLoadCtrlSw: If this option is deselected, handovers are not
triggered for video service UEs based on the video service load in a
cell. If this option is selected, handovers are triggered for video
service UEs based on the video service load in the cell, improving
video service experience.
CaUserLoadTransferSw: If this option is deselected, a CA UE is
considered as one UL-sync UE in both the PCell and SCell when
cell-level MLB counts the number of UL-sync UEs, and
RRC_CONNECTED CA UEs configured with SCells cannot be
transferred. If this option is selected, a CA UE is considered as one
UL-sync UE only in the PCell when cell-level MLB counts the
number of UL-sync UEs, and an RRC_CONNECTED CA UE
configured with an SCell can be transferred during user-number-
based MLB. In addition, the PCell priority for PCC anchoring is
considered, and a higher priority is allocated to the serving
frequency when RRC_REL CA UEs are to be transferred.
DediPrioManageOnLowLoadSw: If this option is deselected, UEs in
lightly loaded cells do not carry the frequency priority dedicated to
load-based cell reselection when the RRC connections of the UEs
are released. If this option is selected and the eNodeB detects a
neighboring E-UTRA frequency with a heavy load, UEs in lightly-
loaded cells carry the frequency priority dedicated to load-based cell
reselection when the RRC connections of the UEs are released, and
the dedicated priority of the heavily-loaded frequency is lowered.
UlHeavyTrafficBaseLoadSw: If this option is deselected, the load of
the target FDD cell is not considered during uplink-traffic-based MLB
to LTE FDD. If this option is selected, the load of the target FDD cell
is considered. If the load of the target FDD cell is high, UEs cannot
be handed over to this cell. This option applies only to LTE TDD.
GUI Value Range:
SpectralEffBasedLoadEvalSw(SpectralEffBasedLoadEvalSw),
VideoSrvLoadCtrlSw(VideoSrvLoadCtrlSw),
CaUserLoadTransferSw(CaUserLoadTransferSw),
DediPrioManageOnLowLoadSw(DediPrioManageOnLowLoadSw),
UlHeavyTrafficBaseLoadSw(UlHeavyTrafficBaseLoadSw)
Unit: None
Actual Value Range: SpectralEffBasedLoadEvalSw,
VideoSrvLoadCtrlSw, CaUserLoadTransferSw,
DediPrioManageOnLowLoadSw, UlHeavyTrafficBaseLoadSw
MML Default Value: None
Recommended Value: SpectralEffBasedLoadEvalSw:Off,
VideoSrvLoadCtrlSw:Off, CaUserLoadTransferSw:Off,
DediPrioManageOnLowLoadSw:Off,
UlHeavyTrafficBaseLoadSw:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance:
SpectralEffBasedLoadEvalSw: If this option is selected, UEs have
similar average throughput in multi-band cells. If this option is
deselected, similar amount of resources are allocated to UEs in
multi-band cells, but UEs have distinctly different average
throughput.
VideoSrvLoadCtrlSw: If this option is selected, video users in multi-
band cells are more likely to require the same amount of
bandwidths. If this option is deselected, video users in multi-band
cells are more likely to require different amount of bandwidths.
CaUserLoadTransferSw: If this option is selected, the MLB
performance and user experience of CA UEs improve when a large
proportion of UEs are CA UEs, but the number of CA UEs'
handovers increases when the eNodeB transfers
RRC_CONNECTED CA UEs. If this option is deselected, loads in
cells may be imbalanced when the proportion of UEs with CA
activated is high, and the number of CA UEs' handovers does not
increase because the eNodeB does not transfer
RRC_CONNECTED CA UEs.
DediPrioManageOnLowLoadSw: Selecting this option prevents UEs
from being transferred back to high-load cells for MLB in networks
where multiple frequency bands with different priorities are used.
This avoids ping-pong cell reselections and ping-pong handovers.
Deselecting this option may increase ping-pong cell reselections or
ping-pong handovers.
UlHeavyTrafficBaseLoadSw: If this option is selected, the load of the
target FDD cell is considered during uplink service-based MLB. If
the cell load is high, UEs cannot be handed over to the target FDD
cell, avoiding user experience deterioration and ping-pong
handovers.
Applicable Mode: L

TrafficMlbSwitch Traffic Meaning: Indicates whether to enable traffic-based MLB algorithms.


MLB UlHeavyTrafficMlbSwitch: Indicates whether to enable uplink heavy
Switch traffic-based MLB. If this option is selected, uplink heavy traffic-
based MLB is enabled, and UEs with heavy traffic in the uplink are
handed over to the target neighboring cell. If this option is
deselected, uplink heavy traffic-based MLB is disabled. This
parameter applies only to LTE TDD cells.
UlHeavyTrafficMlbTFCASw: Indicates whether to enable uplink
heavy traffic-based MLB for TDD+FDD CA UEs. If this option is
selected, uplink heavy traffic-based MLB for LTE TDD+FDD CA UEs
is enabled. LTE TDD+FDD CA UEs with heavy traffic in the uplink
are handed over to the target neighboring cell. If this option is
deselected, uplink heavy traffic-based MLB for LTE TDD+FDD CA
UEs is disabled. This parameter applies only to LTE TDD cells.
GUI Value Range:
UlHeavyTrafficMlbSwitch(UlHeavyTrafficMlbSwitch),
UlHeavyTrafficMlbTFCASw(UlHeavyTrafficMlbTFCASw)
Unit: None
Actual Value Range: UlHeavyTrafficMlbSwitch,
UlHeavyTrafficMlbTFCASw
MML Default Value: None
Recommended Value: UlHeavyTrafficMlbSwitch:Off,
UlHeavyTrafficMlbTFCASw:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: UlHeavyTrafficMlbSwitch: If
this option is deselected, the throughput of UEs in a cell cannot be
maximized due to heavy traffic of some UEs in the uplink. If this
option is selected, the throughput of UEs in a cell increases but the
number of handovers also increases.
UlHeavyTrafficMlbTFCASw: If this option is deselected, the
throughput of UEs in a cell cannot be maximized due to LTE
TDD+FDD CA UEs with heavy traffic in the uplink. If this option is
selected, the throughput of UEs in a cell can be maximized, but the
number of handovers also increases.
Applicable Mode: L

MtcSwitch MTC Meaning: Indicates whether to enable machine type communication


Switch (MTC).
If this parameter is set to ON(On), category 0 UEs can access the
cell.
If this parameter is set to OFF(Off), category 0 UEs cannot access
the cell. This parameter applies only to LTE FDD.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
ON, access of a large number of category 0 UEs to the cell may
cause the PRB usage and cell throughput to decrease. In addition,
the service drop rate may increase because category 0 UEs do not
support handovers. If this parameter is set to OFF, the PRB usage
and throughput of the cell may increase.
Applicable Mode: L

UlIcSwitch Uplink Meaning: Indicates whether to enable the uplink interference


Interferenc coordination algorithm. If the UL_ICS_SWITCH(UlIcSwitch) option is
e deselected, the uplink interference coordination algorithm does not
Coordinati take effect. If the UL_ICS_SWITCH(UlIcSwitch) option is selected,
on Switch the uplink interference coordination algorithm is enabled. This
parameter applies only to LTE TDD networks.
GUI Value Range: UL_ICS_SWITCH(UlIcSwitch)
Unit: None
Actual Value Range: UL_ICS_SWITCH
MML Default Value: None
Recommended Value: UlIcSwitch:Off
Parameter Relationship:
-Others:
1 When the UlIcSwitch option is selected, the uplink coverage is
improved, the throughput of UEs at the cell edge increases, and the
service drop rate decreases in severe uplink interference scenarios.
Deselection of this option does not affect the network.
Service Interrupted After Modification: No
Impact on Radio Network Performance: If the
UL_ICS_SWITCH(UlIcSwitch) is selected, the uplink coverage is
improved, the throughput of UEs at the cell edge increases, and the
service drop rate and uplink average noise and interference (NI)
decrease in severe uplink interference scenarios.
If the UL_ICS_SWITCH(UlIcSwitch) is deselected, it does not affect
the network.
Applicable Mode: L

FcsMode FCS Mode Meaning: Indicates the working mode of the Frequency Channel
Selection (FCS) feature of licensed-assisted access (LAA) cells. If
this parameter is set to MANUAL(MANUAL), the working frequency
of the LAA cell is manually set. If this parameter is set to
ONCE(ONCE), the eNodeB detects interference on the license-
exempt spectrum and automatically configures the working
frequency of the LAA cell. This operation is performed only once
after configuration parameters are delivered. If this parameter is set
to AUTO(AUTO), the eNodeB detects interference on the license-
exempt spectrum and automatically configures the working
frequency of the LAA cell. This operation is performed once after
configuration parameters are delivered and is automatically
triggered when certain conditions are met. This parameter applies
only to LTE FDD.
GUI Value Range: MANUAL(MANUAL), ONCE(ONCE),
AUTO(AUTO)
Unit: None
Actual Value Range: MANUAL, ONCE, AUTO
MML Default Value: None
Recommended Value: AUTO(AUTO)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

ScVideoOptSwitc Sc Video Meaning: Controls the SC-based video optimization feature. If the
h Opt Switch SC_VIDEO_RATE_ADAPT_SW option is deselected, SC-based
video service rate adaptation is disabled. If the
SC_VIDEO_RATE_ADAPT_SW option is selected, SC-based video
service rate adaptation is enabled. This parameter applies only to
LTE FDD.
GUI Value Range: SC_VIDEO_RATE_ADAPT_SW(SC Video Rate
Adapt Switch)
Unit: None
Actual Value Range: SC_VIDEO_RATE_ADAPT_SW
MML Default Value: None
Recommended Value: SC Video Rate Adapt Switch:Off
Parameter Relationship:
-Configuration constraints:
If the DownLoadRateLimitSwitch or VideoRateAdaptSwitch option of
ServiceDiffSwitch in the CellAlgoSwitch MO is selected, the
ScVideoRateAdaptSwitch option of ScVideoOptSwitch in the
CellAlgoSwitch MO cannot be selected. If the
ScVideoRateAdaptSwitch option is selected, neither
DownLoadRateLimitSwitch nor VideoRateAdaptSwitch can be
selected.
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If the
ScVideoRateAdaptSwitch option is selected, the eNodeB
preferentially schedules video services. When UEs are in the cell
center and video service rates are lower than the service
guaranteed bit rate (SGBR), the scheduling probability is higher and
cell throughput increases. When UEs are at the cell edge and video
service rates are lower than the SGBR, the scheduling probability is
higher and cell throughput decreases.
Applicable Mode: L

SpidSpecificHoS SPID Meaning: Indicates the switch that controls SPID-based handover.
witch Specific INTER_FREQ_LIST_CTL_SW: This option controls SPID-based
Handover target frequency list in inter-frequency handovers. If this option is
Switch selected and an RatFreqPriorityGroup MO is configured for an
SPID, UEs with the SPID can be handed over to cells on the
frequency indicated in the RatFreqPriorityGroup MO in inter-
frequency handovers. If this option is deselected, the target
frequency for UEs with the SPID in inter-frequency handovers is not
controlled.
GUI Value Range:
INTER_FREQ_LIST_CTL_SW(INTER_FREQ_LIST_CTL_SW)
Unit: None
Actual Value Range: INTER_FREQ_LIST_CTL_SW
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

DMIMOAlgoSwitc DMIMO Meaning: Indicates whether to enable DMIMO algorithms. This


h Algorithm parameter applies only to LTE TDD networks.
Switch GUI Value Range: DmimoJTSwitch(DmimoJT Switch)
Unit: None
Actual Value Range: DmimoJTSwitch
MML Default Value: None
Recommended Value: DmimoJTSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: None
Applicable Mode: L

UlAmrcMode Uplink Meaning: Indicates the uplink voice AMR control mode. If this
AMR parameter is set to ULAMRC_OFF(ULAMRC_OFF), uplink voice
Control AMR control does not take effect. If RTP packets are encrypted, this
Mode parameter must be set to ULAMRC_OFF(ULAMRC_OFF). If this
parameter is set to
ULAMRC_ENB_CONTROL(ULAMRC_ENB_CONTROL), the
eNodeB executes uplink voice AMR control. If this parameter is set
to ULAMRC_SBC_CONTROL(ULAMRC_SBC_CONTROL), the
eNodeB triggers the session boarder controller (SBC) on the EPC to
execute uplink voice AMR control. The SBC must be a Huawei SBC
supporting uplink voice AMR control.
GUI Value Range: ULAMRC_OFF(ULAMRC_OFF),
ULAMRC_ENB_CONTROL(ULAMRC_ENB_CONTROL),
ULAMRC_SBC_CONTROL(ULAMRC_SBC_CONTROL)
Unit: None
Actual Value Range: ULAMRC_OFF, ULAMRC_ENB_CONTROL,
ULAMRC_SBC_CONTROL
MML Default Value: None
Recommended Value: ULAMRC_OFF(ULAMRC_OFF)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If uplink voice AMR control
is enabled and the uplink channel quality is good, a high voice
coding rate is used. If the uplink channel quality is poor, a low
coding rate is used to improve uplink voice quality.
If voice AMR control results in a high ratio that initial voice coding
rates are tuned up to higher voice coding rates, CCE and RB
resources consumed by voice services increase. When CCEs and
full-buffer services are limited, the throughput rate of data services is
more likely to decrease. If voice AMR control results in a high ratio
that initial voice coding rates are tuned up to lower voice coding
rates, CCE and RB resources consumed by voice services
decrease. When CCEs and full-buffer services are limited, the
throughput rate of data services is more likely to increase.
Applicable Mode: L

AmrcAlgoSwitch AMR Meaning: Indicates the switches of algorithm policies used for
Control adjusting the uplink AMR speech coding rate and related functions.
Algorithm UlAmrcExceedingInitialSw: Indicates whether the adjusted uplink
Switch AMR speech coding rate can exceed the initial coding rate for this
call. The adjusted uplink AMR speech coding rate can exceed the
initial coding rate only if this option is selected.
UlAmrCheckSw: Indicates whether to adjust the uplink AMR speech
coding rate if the eNodeB has not obtained the rate set information
about this session and the UlAmrcMode parameter is set to
ULAMRC_ENB_CONTROL. The uplink AMR speech coding rate
can be adjusted only if this option is deselected.
VoiceCodingModeMeasSw: Indicates whether to measure the
distribution of the numbers of uplink and downlink voice packets in
different speech coding schemes on a per cell basis. If this option is
deselected, the eNodeB does not measure the distribution of the
numbers of uplink and downlink voice packets in different speech
coding schemes on a per cell basis. If this option is selected, the
corresponding counter is incremented based on the frame types
(voice frame and silence frame in different speech coding schemes)
each time the eNodeB PDCP layer receives an uplink or downlink
PDCP SDU with a QCI of 1 in a cell.
GUI Value Range:
UlAmrcExceedingInitialSw(UlAmrcExceedingInitialSw),
UlAmrCheckSw(UlAmrCheckSw),
VoiceCodingModeMeasSw(VoiceCodingModeMeasSw)
Unit: None
Actual Value Range: UlAmrcExceedingInitialSw, UlAmrCheckSw,
VoiceCodingModeMeasSw
MML Default Value: None
Recommended Value: UlAmrcExceedingInitialSw:Off,
UlAmrCheckSw:On, VoiceCodingModeMeasSw:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: UlAmrcExceedingInitialSw:
If this option is selected and the uplink AMR speech coding rate
increases significantly, the uplink voice quality is improved.
However, the voice packet loss rate will slightly increase and the
CCE and RB resources consumed by voice services will increase,
causing a slight decrease in UE- and cell-specific throughput.
UlAmrCheckSw: If the UlAmrcMode parameter is set to
ULAMRC_ENB_CONTROL and this option is deselected, the
adjusted target coding rate may not be adopted by this session.
One-way audio may occur if the coding rate is incompatible on the
UE.
VoiceCodingModeMeasSw: If this option is selected and a large
number of UEs are processing voice services, the CPU usage will
increase. If this option is deselected, there is no impact on network
performance.
Applicable Mode: L

CrsIcSwitch CRS Meaning: Indicates whether to deliver information about intra-


Interferenc frequency neighboring cells for UEs to cancel CRS interference.
e CRS-IC is independent from FeICIC. CRS interference can be
Cancellatio canceled on a per subframe basis.
n Switch If this parameter is set to ON, CRS-IC is enabled and the eNodeB
delivers information about intra-frequency neighboring cells for UEs
to cancel CRS interference.
If this parameter is set to OFF, CRS-IC is disabled and the eNodeB
does not deliver information about intra-frequency neighboring cells
for UEs to cancel CRS interference.
GUI Value Range: OFF(OFF), ON(ON)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(OFF)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
ON, CRS interference decreases between cells densely deployed
and cell-edge UEs have higher throughput. If this parameter is set to
OFF, the CRS interference between cells densely deployed causes
lower throughput for cell-edge UEs.
Applicable Mode: L

MeasOptAlgoSwi Measurem Meaning: Indicates whether to enable measurement-related


tch ent optimization algorithms. GSM_MEAS_DEL_INTERFREQ_SW:
Optimizatio Indicates whether to cancel inter-frequency measurements after a
n GSM measurement is triggered when the UE is performing VoIP
Algorithm services. If the UE is performing VoIP services and this option is
Switch selected, the eNodeB cancels all inter-frequency measurements
when a GSM measurement is triggered. This reduces the GSM
measurement reporting delay. If the UE is performing VoIP services
and this option is deselected, the eNodeB does not cancel inter-
frequency measurements when the GSM measurement is triggered.
MEAS_OBJ_PREEMPT_SW: Indicates whether to enable
preemption when the number of measurement objects of a UE
reaches the specified threshold. If this option is selected and the
number of measurement objects of the UE reaches the specified
threshold, preemption is enabled to ensure that measurements of
algorithms with high priority can be delivered. If this option is
deselected and the number of measurement objects of the UE
reaches the specified threshold, preemption is disabled and the
measurements of algorithms that are triggered later cannot be
delivered.
CSFB_MEAS_DEL_INTERFREQ_SW: Indicates whether to
terminate inter-frequency measurements after a GSM frequency
measurement starts for an E-UTRAN-to-GERAN CS fallback
process. If this option is selected, the eNodeB terminates all inter-
frequency measurements when a GSM frequency measurement is
triggered during the CS fallback process, reducing the GSM
frequency measurement reporting delay. If this option is deselected,
the eNodeB does not terminate inter-frequency measurements when
a GSM frequency measurement is triggered during the CSFB
process. This parameter applies only to LTE TDD cells.
GUI Value Range: GSM_MEAS_DEL_INTERFREQ_SW(Gsm Meas
Del Interfreq Switch), MEAS_OBJ_PREEMPT_SW(Meas Obj
Preempt Switch), CSFB_MEAS_DEL_INTERFREQ_SW(Csfb Meas
Del Interfreq Switch)
Unit: None
Actual Value Range: GSM_MEAS_DEL_INTERFREQ_SW,
MEAS_OBJ_PREEMPT_SW,
CSFB_MEAS_DEL_INTERFREQ_SW
MML Default Value: None
Recommended Value: GSM_MEAS_DEL_INTERFREQ_SW:Off,
MEAS_OBJ_PREEMPT_SW:On,
CSFB_MEAS_DEL_INTERFREQ_SW:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance:
GSM_MEAS_DEL_INTERFREQ_SW: If the UE is performing VoIP
services and this option is selected, inter-frequency measurements
are canceled after a GSM measurement is triggered, reducing the
GSM measurement reporting delay and VoIP call drop rate. If the
UE is performing VoIP services and this option is deselected, inter-
frequency measurements are not canceled after a GSM
measurement is triggered. In this case, the measurement reporting
delay prolongs and the VoIP call drop rate may increase.
MEAS_OBJ_PREEMPT_SW: If this option is selected and the
number of measurement objects of a UE reaches the specified
threshold, the measurements of features and algorithms that are
triggered later can be enabled normally, which improves KPIs. For
example, the service drop rate decreases. If this option is
deselected and the number of measurement objects reaches the
specified threshold, the measurements of features and algorithms
that are triggered later cannot be enabled, which deteriorates KPIs.
For example, a UE cannot perform coverage-based handovers but
perform blind redirection. As a result, the disconnection delay
increases, probably leading to service
drops.CSFB_MEAS_DEL_INTERFREQ_SW: If this option is
selected, inter-frequency measurements are terminated after a GSM
frequency measurement starts for an E-UTRAN-to-GERN CS
fallback process, reducing the GSM frequency measurement
reporting delay and CS fallback delay and improving user
experience. If this option is deselected, inter-frequency
measurements are not terminated after a GSM frequency
measurement starts. In this case, the GSM frequency measurement
reporting delay increases and user experience may deteriorate.
Applicable Mode: L

FreqLayerSwitch Frequency Meaning: This parameter includes the following three options:
Layer UtranFreqLayerMeasSwitch, UtranFreqLayerBlindSwitch, and
Switch UtranSrvccSteeringSwitch. The setting of the option
UtranSrvccSteeringSwitch takes effect only when the
UtranFreqLayerMeasSwitch option is selected.
If the UtranFreqLayerMeasSwitch option is selected, UTRAN
frequency steering takes effect at measurement configuration
delivery for coverage-based handovers to UTRAN or CSFB to
UTRAN. This cell-specific parameter setting takes effect only when
the eNodeB-specific UtranFreqLayerMeasSwitch option is
deselected.
If the UtranFreqLayerBlindSwitch option is selected, UTRAN
frequency steering takes effect at blind coverage-based handovers
to UTRAN or blind CSFB to UTRAN. This cell-specific parameter
setting takes effect only when the eNodeB-specific
UtranFreqLayerBlindSwitch option is deselected.
If the UtranSrvccSteeringSwitch option is selected, UTRAN
frequency steering based on measurements takes effect at
coverage-based SRVCC to UTRAN. This option applies only to
FDD. This cell-specific parameter setting takes effect only when the
eNodeB-specific UtranSrvccSteeringSwitch option is deselected.
GUI Value Range:
UtranFreqLayerMeasSwitch(UtranFreqLayerMeasSwitch),
UtranFreqLayerBlindSwitch(UtranFreqLayerBlindSwitch),
UtranSrvccSteeringSwitch(UtranSrvccSteeringSwitch)
Unit: None
Actual Value Range: UtranFreqLayerMeasSwitch,
UtranFreqLayerBlindSwitch, UtranSrvccSteeringSwitch
MML Default Value: None
Recommended Value: UtranFreqLayerMeasSwitch:Off,
UtranFreqLayerBlindSwitch:Off, UtranSrvccSteeringSwitch:Off
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If the
UtranFreqLayerMeasSwitch option is selected, the UTRAN
frequencies delivered for measurement are selected based on
handover causes and frequency attributes. This setting reduces the
probability that UEs detect certain UTRAN cells during
measurements, resulting in a lower handover probability and a
higher redirection probability.
Applicable Mode: L

EmimoSwitch eMIMO Meaning: Indicates the switch used to enable or disable eMIMO-
Switch related algorithms.
Virtual4T4RSwitch: Indicates whether to enable the virtual 4T4R
function. This switch applies only to FDD.
If this option is selected, the virtual 4T4R function is enabled.
If this option is deselected, the eMIMO sector combination function
is disabled.
EmimoElasticPortSwitch: Indicates whether to enable coordinated
reference signal (RS) scheduling for eMIMO. This option applies
only to FDD. The function is enabled only if this option is selected.
When this option is selected, the eNodeB determines the RS
transmission mode based on inter-cell load status and adopts more
effective link adaptation technologies.
GUI Value Range: Virtual4T4RSwitch(Virtual4T4RSwitch),
EmimoCpsSwitch(EmimoCpsSwitch)
Unit: None
Actual Value Range: Virtual4T4RSwitch, EmimoCpsSwitch
MML Default Value: None
Recommended Value: Virtual4T4RSwitch:Off, EmimoCpsSwitch:Off
Parameter Relationship:
-Configuration constraints:
If the Virtual4T4RSwitch option of EmimoSwitch in the
CellAlgoSwitch MO is selected, options of TM9Switch and
TM10Switch of EnhMIMOSwitch must be deselected.
In the CellAlgoSwitch MO, if the Virtual4T4RSwitch option of
EmimoSwitch is selected, the DlCellCoverEnhanceAlgoSw option of
CellDlCoverEnhanceSwitch must be deselected.
In the CellAlgoSwitch MO, if the Virtual4T4RSwitch option of
EmimoSwitch is selected, GLPwrShare must be set to OFF.
Service Interrupted After Modification: Yes
Impact on Radio Network Performance: Virtual4T4RSwitch:
If this option is selected, resources can be reused in independent
scheduling areas and multi-stream spatial multiplexing can be
implemented in overlapping areas. This setting increases the peak
throughput of cells and the perceivable rate in the overlapping
areas, improving key performance for cells.
If this option is deselected, the virtual 4T4R function does not take
effect and common networking is used.
EmimoCpsSwitch: When this option is selected, UE throughput
increases. When this option is deselected, network performance is
not affected.
Applicable Mode: L

RohcSwitch ROHC Meaning: Indicates whether to enable ROHC in a cell. If this


switch parameter is set to ON, ROCH can be enabled for UEs supporting
ROCH in the cell. If this parameter is set to OFF, ROCH cannot be
enabled for UEs in the cell.
If the eNodeB-level parameter PDCPROHCPARA.RohcSwitch is set
to ON, the setting of this cell-level parameter does not take effect. If
the eNodeB-level parameter PDCPROHCPARA.RohcSwitch is set
to OFF, the setting of this cell-level parameter takes effect.
It is recommended that this parameter be set to ON when a cell
supports VoIP services.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
ON, ROHC is enabled to reduce header overhead of data packets
over the air interface, improving the capacity and the coverage of
VoIP services.
Applicable Mode: L

McpttSwitch MCPTT Meaning: Indicates whether to enable the guarantee functions


Switch related to MCPTT services.
McpttQoSSwitch: Indicates whether to apply GBR to MCPTT
services and prioritize scheduling for MCPTT services. GBR is
applied to MCPTT services and scheduling is prioritized for MCPTT
services only if this option is selected.
McpttCongCtrlSwitch: Indicates whether to enable satisfaction-rate-
based admission for MCPTT services. Satisfaction-rate-based
admission is enabled for MCPTT services only if this option is
selected.
McpttRrcDrxSwitch: Indicates whether to apply a dedicated RRC
connection inactivity timer and a dedicated DRX parameter group to
MCPTT services. A dedicated RRC connection inactivity timer and a
dedicated DRX parameter group are applied to MCPTT services
only if this option is selected.
McpttVoiceMgtSwitch: Indicates whether to apply voice optimization
guarantee to MCPTT services. Voice optimization guarantee is
applied to MCPTT services only if this option is selected.
GUI Value Range: McpttQoSSwitch(McpttQoSSwitch),
McpttCongCtrlSwitch(McpttCongCtrlSwitch),
McpttRrcDrxSwitch(McpttRrcDrxSwitch),
McpttVoiceMgtSwitch(McpttVoiceMgtSwitch)
Unit: None
Actual Value Range: McpttQoSSwitch, McpttCongCtrlSwitch,
McpttRrcDrxSwitch, McpttVoiceMgtSwitch
MML Default Value: None
Recommended Value: McpttQoSSwitch:OFF,
McpttCongCtrlSwitch:OFF, McpttRrcDrxSwitch:OFF,
McpttVoiceMgtSwitch:OFF
Parameter Relationship: None
Service Interrupted After Modification: No
Impact on Radio Network Performance: None
Applicable Mode: L

UlIcsRbRatio UL ICS RB Meaning: Indicates the maximum proportion of RBs that can be
Ratio used for jointly scheduling in the uplink. This parameter applies only
to LTE TDD.
GUI Value Range: 1~100
Unit: %
Actual Value Range: 1~100
MML Default Value: None
Recommended Value: 62
Parameter Relationship: None
Service Interrupted After Modification: No
Impact on Radio Network Performance: If this parameter is set to a
large value, a large number of RBs can be used for joint scheduling
in the uplink, increasing the performance of joint-scheduling UEs. In
this case, a small number of RBs are allocated to non-joint-
scheduling UEs. If this parameter is set to a small value, a small
number of RBs can be used for joint scheduling in the uplink,
degrading the performance of joint-scheduling UEs. In this case, a
large number of RBs are allocated to non-joint-scheduling UEs.
Applicable Mode: L

UlIcsVoLTEPLTh VoLTE Meaning: Indicates the threshold of path loss for selecting VoLTE
Path Loss UEs to preferentially perform uplink joint scheduling. This parameter
Threshold applies only to LTE TDD.
for UL ICS GUI Value Range: 50~150
Unit: dB
Actual Value Range: 50~150
MML Default Value: None
Recommended Value: 115
Parameter Relationship: None
Service Interrupted After Modification: No
Impact on Radio Network Performance: If this parameter is set to a
large value, a small number of VoLTE UEs are selected for UL ICS.
If this parameter is set to a small value, a large number of VoLTE
UEs are selected for UL ICS.
Applicable Mode: L

DacqSwitch DACQ Meaning: Indicates whether to enable dynamic AMBR control by


Switch QCI (DACQ). If this parameter is set to ON(On), DACQ is enabled. If
this parameter is set to OFF(Off), DACQ is disabled. This parameter
applies only to LTE TDD cells.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
OFF(Off), DACQ is disabled. If this parameter is set to ON(On),
DACQ is enabled.
Applicable Mode: L

RrcReestDataFw RRC Meaning: Indicates whether to allow a serving eNodeB forwards


dSwitch Reestablis data that has not been sent to a UE yet from the source cell to the
hment target cell when the UE experiences an RRC connection
Data reestablishment so that the target cell can send the data to the UE.
Forwarding If this parameter is set to ON(On), when the RRC connection is
Switch reestablished to the target cell, the eNodeB sends the data from the
source cell to the target cell and the target cell sends the data to the
UE. If this parameter is set to OFF(Off), the eNodeB directly
discards the data in the preceding scenario.
GUI Value Range: OFF(Off), ON(On)
Unit: None
Actual Value Range: OFF, ON
MML Default Value: None
Recommended Value: OFF(Off)
Parameter Relationship: None
Service Interrupted After Modification: No (And no impact on the UE
in idle mode)
Impact on Radio Network Performance: If this parameter is set to
ON, the possibility of TCP/UDP packet loss due to RRC connection
reestablishments decreases. Setting this parameter to OFF results
in the opposite effect. If this parameter is set to ON for a cell in
which the proportion of RRC connection reestablishments is greater
than 2%, the bit error rate (BER), RLC transmission rate, and
service drop rate increase, and the RRC connection reestablishment
success rate and RRC connection establishment rate decrease.
Applicable Mode: L

Example

Example 1: To modify the settings of cell-level algorithm switches with


the parameters as follows: Local cell ID: 0, Dynamic adjust voltage
algorithm switch: DynAdjVoltSwitch-1, run the following command:
MOD CELLALGOSWITCH: LocalCellId=0, DynAdjVoltSwitch=DynAdjVoltSwitch-1;
Example 2: To modify the settings of cell-level algorithm switches with
the parameters as follows: Local cell ID: 0, PUCCH algorithm switch:
PucchSwitch-1, run the following command:
MOD CELLALGOSWITCH: LocalCellId=0, PucchAlgoSwitch=PucchSwitch-1;

Huawei Proprietary and Confidential


Copyright © Huawei Technologies Co., Ltd.

S-ar putea să vă placă și