Sunteți pe pagina 1din 517

Product Release Letter

AVEVA Hull & Outfitting 12.1.SP4.56


Partial Fix Release 80460
Windows 7
Dear Customer
This letter introduces and describes this release, which is supported on the indicated platform(s).

This Release Contains


A partial fix release which upgrades the Full Release 80294, AVEVA Hull & Outfitting 12.1.SP4
and replaces AVEVA Hull and Outfitting 12.1.SP4.55.

The separately licensed products or product components installable from or upgraded by this
release are as follows:

Product Version
Product Name
Code Number
V00FN517 AVEVA Initial Design Geometry 12.1.SP4
V00FN518 AVEVA Initial Design Hydrostatics 12.1.SP4
V00FN519 AVEVA Initial Design Hydrodynamics 12.1.SP4
V00FN510 AVEVA Hull Structural Design 12.1.SP4
V00FN520 AVEVA Hull Detailed Design 12.1.SP4
V00FN957 AVEVA Hull Panel Line Control 12.1.SP4
V00FN951 AVEVA Hull Profile Cutting Interface 12.1.SP4
V00FN953 AVEVA Hull Plate Cutting Interface 12.1.SP4
V00FN954 AVEVA Hull Genauigkeit - GSD Marking Triangles 12.1.SP4
V00FN952 AVEVA Hull Dotori - Variable Bevelling 12.1.SP4
V00FN959 AVEVA Hull Robot Interface 12.1.SP4
V00FN960 AVEVA Hull Robot Interface 2 (STEP Based) 12.1.SP4
V00FN90nn AVEVA Hull Postprocessors 12.1.SP4
V00FN542 AVEVA Hull Weld Planning 12.1.SP4
V00FN531 AVEVA Marine Drafting 12.1.SP4
V00FN545 AVEVA Outfitting 12.1.SP4
V00FN539 AVEVA Room Design 12.1.SP4
V00FN538 AVEVA Cable Design 12.1.SP4
V00FN521 AVEVA QUERY 12.1.SP4
V00FN522 AVEVA Laser Model Interface 12.1.SP4
V00FN425 AVEVA Engineering ( incorporates Schematic Model Manager) 12.1.SP4

For further information please contact your local AVEVA support office, which can be found at
http://support.aveva.com

This document has been prepared and approved by the following:


Job Title Name
Senior Technical Writer Lena Strand
Test Manager Sachin V Yadav
Head of Product Anders Carlsson

File: d80460.doc
Last saved: 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 1 of 517
Product Release Letter
Product Version
Product Name
Code Number
V00FN536 AVEVA Diagrams 12.1.SP4
V00FN537 AVEVA Schematic 3D Integrator 12.1.SP4
V00FN541 AVEVA Assembly Planning 12.1.SP4
V00FN540 AVEVA Multi-Discipline Supports 12.1.SP4
V10FN806 AVEVA Area Based Automatic Drawing Production 12.1.SP4
V30FN526 AVEVA ExPLANT-I 12.1.SP4
V30FN961 AVEVA ExPLANT-A 12.1.SP4
V00FN978 AVEVA Mechanical Equipment Interface - Export 12.1.SP4
V00FN977 AVEVA Mechanical Equipment Interface - Import 12.1.SP4
V00FN546 AVEVA Hull Finite Element Modeller 12.1.SP4
V00FN543 AVEVA Space Management 12.1.SP4
V00FN547 AVEVA Surface Manager 12.1.SP4
V00FN549 AVEVA Design Reuse 12.1.SP4
V00FN814 AVEVA Isometric Automatic Drawing Production 12.1.SP4
V30FN527 AVEVA Pipe Stress Interface 12.1.SP4

Prerequisite for this release - operating system:


Minimum Supported O/S Version Windows 7 (32- or 64-bit)
(for each supported platform) with Microsoft .NET Framework 3.5 (supplied)
Mandatory O/S Patches Windows 7 – Service Pack 1
(for each supported platform)
Build Operating System Windows Server 2008 R2

*1 Please note that a Windows Platform Update (Windows 7 SP1 and Windows Server 2008 R2 SP1) is a pre-requisite for accurate
2D rendering (for example Text graphics) in the 3D canvas (http://support.microsoft.com/kb/2670838 ).

*2 Microsoft has announced that support for Windows XP has now ended : please refer to:
http://support.aveva.com/support/United_Kingdom/bulletins/xp-update-2.htm.

*3 AVEVA supports the use of Windows Server 2012 R2 as a file server for projects deployed with AVEVA Hull and Outfitting
12.1.SP4, AVEVA Engineering 12.1.SP4, AVEVA Diagrams 12.1.SP4 & associated products.

*4 AVEVA supports the use of Windows Server 2016 as a file server for projects deployed with AVEVA Hull and Outfitting 12.1.SP4.

*5 Please note that recommended/supported hardware and software configurations are constantly subject to review, so please consult
the AVEVA support web pages for the latest recommendations.

Prerequisite for this release - products:


• AVEVA Hull & Outfitting 12.1.SP4.
• AVEVA Licensing System 1.1 (or later) and an appropriate License File (N.B. This
product version does NOT work with AVEVA Flexman)

Microsoft Office 2007 or 2010 (32-bit) is required for some functions:


• Optimum operation of the AVEVA Design Platform GUI requires Arial Unicode MS font,
supplied with Microsoft Office (2000 onwards) and also with Microsoft Office Visio.
• Microsoft Office Excel import requires “.NET Programmability Support” enabled when
Office is installed. This can be found under “Advanced customization of applications” and
installs the Microsoft.Office.Interop.Excel.dll; without this, Excel import will not work.
• Microsoft Office Visio 2007 or 2010 (Standard edition, 32-bit) is required for AVEVA
Diagrams and for the AVEVA Schematic Model Viewer.
• AVEVA Hull & Outfitting 12.1.SP4 has been verified with Microsoft® Office 2016.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 2 of 517


Product Release Letter
For full details, please refer to the AVEVA Marine 12.1 System Requirements manual.

Works (is compatible) with:


• Other AVEVA Hull and Outfitting products on DVD 41234 (Hull and Outfitting 12.1.SP4 and
associated products).
• AVEVA Administration 1.6
• AVEVA Bocad 2.3
• AVEVA Bocad Steel Interface 2.2
• AVEVA Clash Manager 14.2.0
• AVEVA Client Cache Service 1.0.4
• AVEVA Diagrams 12.1.4 and 14.1
• AVEVA Electrical 12.1.3
• AVEVA Engineering 12.1.4 and 14.1.1
• AVEVA Everything3D™ 2.1
Please refer to AVEVA Everything3D™ 2.1 Release Letter and Migration & Interoperability Guide for
interoperability considerations when using 12.1.SP4 and AVEVA Everything3D™ 2.1 together.
• AVEVA Global Server 12.1.4 and 3.2.1
• AVEVA Instrumentation 12.1.3
• AVEVA Integration Services 1.2
• AVEVA Laser Modeller 12.0
• AVEVA NET Gateways 4.8.1
• AVEVA NET Portal 4.7.7
• AVEVA Open Steel 2.3
• AVEVA P&ID 12.1.2
• AVEVA Pipe Stress Interface 2.1
• AVEVA PLM Publisher 2.2
• AVEVA Review 12.2
• AVEVA Schematic 3D Integrator 12.1.4
A full and up to date compatibility matrix can be found via compatibility.aveva.com/matrix.

Supersedes:
Release 80454 - AVEVA Hull and Outfitting 12.1.SP4.55.

To Install Product Release:


Please double-click the installer (file Marine12.1.SP4.56.exe) and follow the instructions. De-
installation of the fix release is possible via the Windows Add or Remove programs facility.

Please note that there is now a combined installer for Hull & Outfitting and the associated products
listed above. This can be configured by using the check boxes to install a selection of products; it
may also be used to add additional ones or remove them at a later date.
• Simple installations (using setup.exe) will install to C:\ but the individual .msi files will use the
default drive.
• If you require sample projects, please ensure that you check the ‘Hull & Outfitting models’ box.
• The Global tick-box installs the necessary support for Global use of Hull & Outfitting for Global
Client. There is a separate installer for the Global server. It will be installed, by default, under
C:\Program Files (x86)\AVEVA. Please note that Global Server should not be installed in the
same folder where Hull & Outfitting has been installed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 3 of 517


Product Release Letter
IMPORTANT NOTES:

New Capabilities in the Dabacon Core


When Engineering 15.1 and Administration 1.6 are released it will be possible to create Notes and
Arrays of Strings using these products.
Because these are new capabilities in the Dabacon core, it will not be possible to display or use
such data in older products :
• PDMS
• Hull & Outfitting
• Everything3D 2.1
AVEVA Marine 12.1.SP4 Surface & Compartment new version of Spatial ACIS
In the main release of AVEVA Marine 12.1.SP4 Surface & Compartment a new version of Spatial ACIS were
included. With the ACIS upgrade a new faceting engine was introduced, with the old faceting still in
operation but without the user settings of tolerances available.

To overcome this issue there was a switch to the new faceting engine in 12.1.SP4 fix 27 where user set
tolerances once again are available, except for the aspect ratio setting which is now obsolete.

NOTE! Changes to the faceting may result in differences in Hydrostatics results.


Weight and Centre of Gravity (WCoG)
Various problems for WCoG in Hull has been detected in 12.1.SP4.33 to 12.1.SP4.36.
• wcog name & type in resulting WCOG.csv file - SP4.36 (fixed in 12.1.SP4.37)
• When run WCoG in 12.1.SP4 Fix35, the program will finish with error 1002 or 1005. (fixed in
12.1.SP4.36)
• WCoG problem of drawing with bracket (fixed in 12.1.SP4.36)
• WCOG of SBP panel incorrect (fixed in 12.1.SP4.35)
• "+ gap" is twice added to deployed bracket. (fixed in 12.1.SP4.34)
These fixes are all included in 12.1.SP4.37 and affects the weight of brackets and also the column Type in
the WCoG result list.
The weight of brackets are, in case of bevel is used, corrected to include the bevel (see fix for 12.1.SP4.34).
AVEVA Marine Surface and Compartment 12.1.SP4 Fix 26
Customers using AVEVA Marine Surface & Compartment may have problems opening surface
files in version 12.1.SP4 Fix.26. Symptom is that the system freezes and the process must be
killed. Target for a fix for this issue is 12.1.SP4 Fix.27.
AVEVA Cache Service
As a result of interaction between fixes made to Dabacon and the AVEVA Client Cache Service, it
is recommended that after installing this version, 12.1.SP4 Fix.21, the client cache on each client
machine is emptied using the Cache Manager.

Compatibility Issue

Due to compatibility issues, the Compare/Update feature of 12.1.SP4 Fix.21 (Diagrams,


Engineering & Outfitting modules) does not work successfully with AVEVA Instrumentation
12.1.SP3 Fix.4. This will be resolved with the upcoming release of AVEVA Instrumentation
12.1.SP3 Fix.5.
Production Support for Frameworks
The possibility to select a Framework graphically in the 2D canvas or to get relevant options when
Right-Clicking a Framework in the 2D canvas is dependent on the optional database upgrade
defined in AVEVA Marine 12.1 SP3. See the AVEVA Marine 12.1 SP3 bulletin note 19.9 Layers for
Outfitting Models for details.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 4 of 517


Product Release Letter
New Representation
When setting SBH_ENABLE_SOLID_PLATES shell plates can now be represented using a
Generic Primitive created from the referenced surface and the involved seams in that surface.
The new representation is used also when generating bending templates. If issues are
encountered, it is recommended not to use this setting.
New Bending Templates IP
The new bending templates IP named LARGESIGHTLINEMARK is subject to change in a coming
hotfix release and should not yet be used.
Datasheets Performance and Printers
Performance of some features, such as the new Datasheets, may be impaired if your default
printer is not accessible. This is believed to be due to the use of Excel functions; a detailed
investigation is under way.
Support for Datasheet Templates Created in Foreign Project Databases
The current released version of “Datasheets ” in AVEVA PDMS 12.1.SP4 does not support
datasheet templates created in a foreign project dictionary. All datasheet templates “MUST” be
created in the current project dictionary database for them to be available for use in AVEVA
Engineering -Tags.
Installation
There is a prerequisite to have Windows Explorer as your default Internet browser. If you choose
to install from the DVD’s html menu, other browsers might have a different behaviour that prevents
a successful installation.

After the Marine installation has completed an installation of the AVEVA Database Cache Service
is started automatically. A prerequisite for AVEVA Database Cache Service is that the Microsoft
Message Queuing (MSMQ) is enabled. For a description of enabling the MSMQ and the use of
AVEVA Database Cache Service, please refer to chapter AVEVA Database Cache Service in the
Marine Software Installation Guide.

Database Optional Upgrade

The database upgrade framework is extended with a concept of optional upgrades. The software
requires a database to be upgraded to a certain level to be granted write access to the database.
But beyond that mandatory upgrade level it is now possible to apply further optional upgrade levels
to acquire new enhanced features. For more information please see the Data Management and
Database Administrator User Guide / Database Upgrade.

The impact of the PML Form Layout Changes

PML developers using the new Forms and Menus libraries, may discover unacceptable changes to
the layout of some existing forms when upgrading from earlier releases. The fix for the layout
changes is usually straight forward. For further information please see item KB4453 in the
Knowledge Base .

P&ID Integration UDA Definition Change


If using the AVEVA P&ID to Tags integration in Compare/Update, please note that the integration
UDA pmg-engi-pid should have its UDA Length increased to 150 characters.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 5 of 517


Product Release Letter
First released on:
This product release is first available on AVEVA support website http://support.aveva.com as
AVEVA Marine Hull & Outfitting 12.1.SP4.56, release number 80460.

List of Enhancements
This release includes the following functional enhancements:
In this release:

No Enhancements.

Consolidated from previous fix releases:

12.1.SP4.53

Description
Run mode for Hull PPI

Description
When starting a Hull job in PPI it is always sent to the LogViewer.
An addition has been made to be able to run the job in the same session as the main session.

This can be switched I nthe PPI main menu with that “Run Mode…” button.

By click that function it will toggle between “In LogViewer” and “In Session”.
“In LogViewer” will send the job to the log viewer and “In Session” will run the job in the main session.

This is implemented for the following applications:

Hull Plane Part Gen.

Hull Curved Part Gen.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 6 of 517


Product Release Letter
Hull Profile Sketch / List

Hull Parts List

Hull Plate Interface

Hull Bending Templates

Hull Weight / COG

Benefits
This will make it possible to quickly get a result for production parts.

Compatibility Constraints
None.

For More Information


None.

Affected Programs
AVEVA Marine

Description
API for Hull PPI

Description
An API has been added to help customers to setup and run the Hull Production Programs.

The API is the same call for all the functions.

The object is MARHULLPPI and it contains only one method.

RunPPI( action, name, argument)

<action> = PPI function to run

This is the short name of the program to run. It is the same short name that can be found in
marjobs.xml in the installation catalogue. Currently the following applications are implemented:

“ppanparts” - Hull Plane Part Gen.

“cpanparts” - Hull Curved Part Gen.

“tprprofint” - Hull Profile Sketch / List

“partlist” - Hull Parts List

“tbrplateint” - Hull Plate Interface

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 7 of 517


Product Release Letter
“bendtempl” - Hull Bending Templates

“wcog” - Hull Weight / COG

<name> = panel name or file containing PPI input data

This is a name of a panel (planar/curved) or a filename (including full path) containing a list of panels in
the format for PPI.

<argument> = IP group to use

Certain applications may have their default file (ip) divided into one or several groups. This parameter
may then contain the group to use.

Example of short script in PML:


import 'marapi'
using namespace 'AVEVA.Marine.Design'
using namespace 'Aveva.Marine.Utility'
!hppi = object MARHULLPPI()
!fname = 'ER2-CPLP2P'
!argument = 'JP'
!action = 'ppanparts'
!hppi.RunPPI(!action, !fname, !argument)
!action = 'cpanparts'
!hppi.RunPPI(!action, !fname, !argument)
!action = 'tbrprofint'
!hppi.RunPPI(!action, !fname, !argument)
!action = 'tbrplateint'
!hppi.RunPPI(!action, !fname, !argument)
!action = 'partlist'
!hppi.RunPPI(!action, !fname, !argument)

Benefits
This will make it possible for customisations in the production support.

Compatibility Constraints
None.

For More Information


None.

Affected Programs
AVEVA Marine

Description
Additions for Right Click on Hull Panel

Description
Additions has been made to the Right Click on a Hull Panel.
For Planar Panels, the “Generate Parts” has been available for some time. This is now also available

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 8 of 517


Product Release Letter
for Curved Panels.
Also additional production programs have been added:

The added functions works for both Planar and Curved Panels.

Benefits
This will make it possible quickly run a Planar or Curved panel through the production programs.

Compatibility Constraints
None.

For More Information


None.

Affected Programs
AVEVA Marine

12.1.SP4.50

Description
Marine Drafting – New MarAPI functions FormInsert and SubpictureTransfer

Description
In Marine Drafting 12.1 SP4 Hotfix, two new MarAPI functions have been introduced:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 9 of 517


Product Release Letter
FormInsert

SubpictureTransfer

FormInsert is used to insert/exchange a drawing form in the current drawing.

SubpictureTransfer is used to copy a view/subview/component in the current drawing to another


drawing in the database.

Benefits
Convenient tools for inserting forms and transferring subpictures in Marine Drawing.

Compatibility Constraints

None

For More Information


Please see the Marine Drafting documentation of Vitesse functions:
• Form_insert
• Subpicture_transfer
and corresponding MarAPI functions
• FormInsert
• SubpictureTransfer

Affected Programs
Hull Design, Marine Drafting

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 10 of 517


Product Release Letter
Description
Weld Suspension

Description
Weld, defined in hull panels along traces, can now be detailed to also suspension

The scheme syntax uses the new keywords SUS with two parameters for suspension in start and end
of trace. The new keyword is used in statements WELD and STIFFENER.

Benefits
A more accurate definition of welds

Compatibility Constraints
None

For More Information


Only noted here.

Affected Programs
AVEVA Marine Planar Hull

Description
Weld Methods

Description
Weld methods can now be defined in hull modelling on along panel boundaries and on stiffeners (along
trace and at ends), on flanges (at ends), on pillars (at ends), on brackets (along bracket legs) and on
doubling plates.

The weld methods to be used are defined in the bevel control file and assigned as possible methods on
selected bevel codes.

The Statement Wizard in hull modelling is updated allowing the user to select weld methods from drop
down lists.

The panel syntax is updated with keyword controlling the setting of weld methods.

The assigned weld methods are presented in the generic files for plates and profiles.

Benefits
Weld details can be defined by the production designer

Compatibility Constraints
None

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 11 of 517


Product Release Letter
For More Information
Only noted here.

Affected Programs
AVEVA Marine Planar Hull

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 12 of 517


Product Release Letter
Description
Shell Plate Symbolic View

Description
The Shell Plate Symbolic View can be used to inspect a developed plate.
It is now added also a possibility to visualize the strips used to develop the plate to help the user to
inspect and possible modify the development process.

To do this, a new default keyword to Hull Modelling is implemented, DEV_PLATE_VIEW_STRIPS,


which can have two values:

YES The strip marking will be visualized in the symbolic view.

NO No strip marking is displayed. This is the default behaviour.

DEV_PLATE_VIEW_STRIPS=YES DEV_PLATE_VIEW_STRIPS=NO

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 13 of 517


Product Release Letter
Benefits
Helps the user to inspect and modify the outcome of the plate development.

Compatibility Constraints
None.

For More Information


None.

Affected Programs
Hull Modelling.

12.1.SP4.49

Description
Marine Drafting – Dynamic Feed-Back when Creating/updating Dimensionings

Description
In Marine Drafting 12.1 SP4, dynamic feed-back has been implemented in functions creating or
updating dimensionings:

• When supplying each measure point in Linear 2d/3d Dimensioning creation

• When locating the dimension line in Linear 2d/3d/Axis Parallel Dimensioning creation

• When locating the leader line in Radius/Diameter Dimensioning creation

• When moving radius/diameter text in Modify/Dimension/Move Dimension Text function

• When moving the dimension line in Modify/Dimension/Move Dimension Line function

• When changing witness line direction in Modify/Dimension/Slant Witness Line function

Also, some other improvements:

• Snapping to cardinal axis during "Modify/Dimension/Slant Witness Line" now also in 3D.

• When checking placement for “text outside” in Linear 2d/3d Dimensioning creation, no need for
user to indicate side explicit (during location of dimension line, the hair-cross position gives the
wanted side)

• When creating Axis Parallel dimensioning, side for text is now derived when locating the
dimension line.

Benefits
Improved user feed-back when creating/updating dimensionings (WYSIWYG)

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 14 of 517


Product Release Letter
Compatibility Constraints
None

For More Information


None

Affected Programs
Hull Design, Marine Drafting

Description
Marine Drafting – Moving texts in Radius/Diameter Dimensionings

Description
In Marine Drafting 12.1 SP4 it is now possible to move the text in Diameter and Radius dimensionings
also parallell to the reference line in the interactive function Modify Dimensioning/Move Dimension Text.
This means that the text can be moved "freely". However, for dimensionings of type Straight, Knuckled
and Cross with text outside, the offset cannot be negative (while it can for type Cross with text inside).
During positioning of the text, the user is guided by dynamic highlighting..

In PADD, the “offset text along reference line” is preserved by the u-component of attribute DTOF of
PDIM element. The offset when creating new dimensionings is zero (like in previous versions).

Benefits
Possibility to move dimension text freely, with dynamic feed-back.

Compatibility Constraints
None

For More Information


None

Affected Programs
Hull Design, Marine Drafting

Description
Marine Drafting – Available Space for Dimension Texts using Default Keyword
DIM_FAC4

Description
In Marine Drafting 12.1 SP4 it is now possible to safely control the strategy for deriving available space
for dimension texts.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 15 of 517


Product Release Letter
When creating dimensionings (linear, cross radius/diameter, curve), the available space for the
dimension text has by default been derived as the gap between the arrows, not between the witness
lines. Moreover, the default keyword DIM_FAC4 has been used to define the “clearance” between the
arrows and the dimension text (this factor multiplied with the arrow length). The system default value is
0.3. Setting this factor to zero means no clearance. Negative values has been allowed but not
recommended.

In case the dimension text does not fit, the size of it will optionally be reduced in order to fit within the
available space. The reduction involves primarily decreasing the aspect and if that is not enough, the
height is also decreased. This behavior is controlled by the default keywords DIM_TEXT_ASPECT_FIT
and DIM_LIN_FIT.

A drawback is that the height of the dimension text might be reduced unnecessarily much, making it
hard to read the text.

To get better readability of dimension texts in narrow sections, user can make system ignore the arrows
during available space calculation, by setting DIM_FAC4 to -1.0. This approach has always been
possible but the result has not always been reliable.

In this release of Marine Drafting, this approach can be used safely.

Benefits
Possibility to safely control the available space for dimension texts

Compatibility Constraints
None

For More Information


None

Affected Programs
Hull Design, Marine Drafting

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 16 of 517


Product Release Letter
12.1.SP4.48

Description
The State of Hull Component

Description
Hull component stiffeners, plates and brackets now have new attributes to support checking quality and
maturity of the hull model.

Modelling state is captured in attribute MODSTY and can be set manually using a pseudo attribute
MODSTA to values “Preliminary”, “ByRule” or “Manual”. Typically, if customer creates/modifies hull
components with own software, state can then be set to “ByRule”.

“Preliminary” is set by system when thickness of plate or bracket is set to zero and when stiffener is
defined without endcut. Once these properties are given, state will be changed to “Manual”.

If component is set “ByRule” and component is changed using AVEVA standard functions, then state is
set to “Manual”.

Hull components with position numbers assigned are normally in a state where it is important to
understand if changes have occurred. If a stiffener, a plate or a bracket with position number defined is
changed by the user, then the new attribute ISCHGD is set to true. Comparison criteria is geometry and
properties affecting the actual manufacturing part that will be the result of the hull component.

The automatic generation of position numbers can look for changed parts, resort them and eventually
give them new position numbers.

Benefits
Better possibilities to check the quality of the model

Compatibility Constraints
None

For More Information


Only noted here.

Affected Programs
AVEVA Marine Planar Hull

Description
New API for Planar Panel Customizations

Description
A new API, Aveva.Marine.Planar, is introduced to edit hull element properties efficiently. The API is
based on the scheme statement syntax and statement keywords that can be queried and set using
dedicated objects and methods. Furthermore, topologically related elements, e.g. going from bracket
arm to related stiffener, can be found by reference methods supplied by the new API.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 17 of 517


Product Release Letter
The execution of the created/modified statements will be done as before using the MarHullPan object in
the marAPI.

The API is available both from PML and .Net environments.

Benefits
More easier access and editing planar panel components via customization add-ins.
This will lead to more easier execution of Rule Based Design principals.

Compatibility Constraints
None

For More Information


Contact your local support for more information.

Affected Programs
AVEVA Marine Planar Hull

12.1.SP4.46

Description
Enhanced for handling of Hull Text

Description
When a Hull Text is to be projected, the Hull Text drawing must be organized in a correct way. This can
be achieved with help of the functions Split Subpicture. It is, however, a complicated task to get this
Hull Text drawing in perfect shape with respect to its internal organisation.

Each level in the picture must also have specific and correct attributes.
For this, there is now introduced a new function to help organising the drawing.

The function is under Hull Tools → Hull Text → Verify.


This should be invoked when the Hull Text drawing is current.

Before invoking the function, the Hull Text should be reorganised with help of Split Subpicture and each
element that should be projected, placed on Component level:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 18 of 517


Product Release Letter

When this is done, invoke the Hull Text → Verify function and the system will automatically reorganise
the drawing to be in a correct state and ready for projection, as in the first picture above.

An example:

Benefits
This will make the projection of the Hull Text, when made as plates, more accurate.

Compatibility Constraints
None.

For More Information


None.

Affected Programs
AVEVA Marine

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 19 of 517


Product Release Letter
12.1.SP4.44

Description
Marine Drafting – New MarAPI function PlatePartInsert

Description
In Marine Drafting 12.1 SP4 Hotfix, a new MarAPI function PlatePartInsert has been introduced. The
function is used to insert a Plate Part View in the Marine drawing, given the name of the plate part
object.

Benefits
Convenient tool for creating a Plate Part view in the Marine Drawing.

Compatibility Constraints
None

For More Information


Only noted here.

Affected Programs
Hull Design, Marine Drafting

12.1.SP4.43

Description
Marine Drafting – User Confirm of Layer Status Report

Description
Whenever a drawing is opened or a new one is created, the current status of layer settings is reported
in the message window (e.g. “The following layers are hidden …”).

In Marine Drafting 12.1 SP4 it is now possible to control if the Layer Status Report should be confirmed
by user. The intention is to force user pay attention to the report.

For this purpose, a new Drafting Default Keyword has been introduced.
Keyword:

LAYER_STATUS_REPORT_CONFIRM
System default value:

“Never”

Explanation:

When a drawing is opened or a new one is created (also via Marapi functions DwgNew and DwgOpen),
this keyword controls if the Layer Status Report should be confirmed by user.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 20 of 517


Product Release Letter
Legal values:

"Never” No user confirm

"Always" Let user confirm the report

Benefits
Possibility to force user pay attention to layer status report

Compatibility Constraints
None

For More Information


Only stated here.

Affected Programs
Hull Design, Marine Drafting

12.1.SP4.42

Description
Copy Assistant API

Description
A new .NET class is defined with two methods (Export and Import) and marked as PMLNetCallable and
can thereby be called from PML.

This enabled for customized development using utilizing two exposed methods Export and Import.

Import 'CopyAssistAddin'

using namespace 'CopyAssistAddin'

!copyobj = object CopyAssist()

The CopyAssist object expose two methods, Export and Import where both take a string argument.

!copyobj.export('C:\Temp\CSuites\CopySuite1.sxs')

!copyobj.import('C:\Temp\CSuites\CopySuite1.sxs')

The string argument is meant to refer a file describing input data for Export and Import operations. Such
a file is denoted as a Copy Suite consisting of a number of Copy Sets where each Copy Set contains a
selection of elements. A Copy Suite file is used for both Export and Import operations but the selection
of elements is used only at Export and ignored at Import. Following example of a Copy Suite file shows
two Copy Sets (CopySet1 and CopySet2) both with selection of three elements for export. At Import
only the name of Copy Set is fetched from the Copy Suite while element information is retrieved from
the Copy Set folder (CopySet1 alt CopySet2). There is no schema definition to validate the correctness
of data so preparing a Copy Suite file requires accuracy. However, a logging mechanism is provided to

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 21 of 517


Product Release Letter
direct failure messages to file on %TMP%/<CopySuiteName>_export.log alt
%TMP%/<CopySuiteName>_import.log

<copysuite>

<copyset file="C:\Temp\CSets\CopySet1">

<selection>

<element name="/ER2-LP32_2" />

<element name="/ER2-LP38_2" />

<element name="/ER2-BHD-FR35-1" />

</selection>

</copyset>

<copyset file="C:\Temp\CSets\CopySet2">

<selection>

<element name="/ER2-BHD-FR35-2" />

<element name="/ER2-BHD-FR35-3" />

<element name="/ER2-BHDFR42-1" />

</selection>

</copyset>

</copysuite>

The mechanism provided through the Options function in graphical User Interface of Copy Assistant to
find dependencies (follow references to connected elements) is not supported in the functionality
above.

Benefits
This enabled for customised development utilising these two methods in interface.

Compatibility Constraints
None

For More Information


User Guide

Affected Programs
Marine Drafting and Hull Design.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 22 of 517


Product Release Letter
12.1.SP4.41

Description

Marine Drafting – Text Alignment User Interface

Description
The default text alignment in Marine Drafting has so far been Horizontal "Left" and Vertical "Base Line"
without possibility for user to control.

In Marine Drafting 12.1 SP4 Hotfix, a user interface for controlling the alignment while placing a text in
the drawing has been introduced.

A new toolbar "Text Alignment", offering horizontal alignments "Left", "Centre" and "Right", and vertical
alignments "Top", "Half Height", "Middle", "Base Line" and "Bottom", will be enabled whenever a text is
about to be positioned in the drawing.

Alignment control is available in following functionality:

- Annotate/Label

- Annotate/Markup

- Insert/Text

- Dimension/Area

- Dimension/Distance

- Modify/Label/Move

- Modify/Move/Text

- Modify/Copy/Text

At start-up of Marine Drafting, the default text alignment is "Left" and "Base Line" as before.

Note that when changing text status during multi-row text insertion, the “Text Corner Reference” choice
has been removed (now covered by alignment functionality). Also note that when aligning multi-row text
horizontally, all rows will be justified according to selected alignment.

The alignment is useful also when aligning to other texts in the drawing, e.g. when using the "2D Lock"
toolbar options while moving the text.

Benefits
Improved functionality and user control while positioning text in the drawing.

Compatibility Constraints

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 23 of 517


Product Release Letter
None

For More Information


See documentation of interactive function Insert/Text for details about “Text Alignment”.

Affected Programs
Hull Design, Marine Drafting

Description
Marine Drafting – Model type and Draw Code Selection in Exchange Model View

Description
In Marine Drafting 12.1 SP4, the User interface in Exchange Model View function has been somewhat
adjusted.

The “Model type” selection dialog has been removed, in order to obtain consistency with the
corresponding “Update Design” command. By default, all types of models will be exchanged.

The “Model Draw code” selection dialog will only appear if necessary (if there are Hull models the view)

Benefits
Better consistency and productivity

Compatibility Constraints
None

For More Information

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 24 of 517


Product Release Letter
Please see the Marine Drafting documentation.

Affected Programs
Hull Design, Marine Drafting

12.1.SP4.40

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 25 of 517


Product Release Letter
Description
Marine Drafting – Default target view in Insert Model

Description
In Marine Drafting 12.1 SP4 it is now possible to control the initial target view the first time the function
Insert/Model is invoked. After that, system will remember last option used (like today).

For this purpose a new Drafting Default Keyword has been introduced.

Keyword:

INSERT_MODEL_INITIAL_VIEW

System default value:

“All”

Explanation:

After system start up, first time Insert/Model is used, the View dropdown menu will initiated to this value

Legal values:

"New” Collected models will be inserted in a new view


"All" Collected models will be inserted in all views

Benefits
Possibility to control the initial behaviour in Insert/Model function

Compatibility Constraints
None

For More Information


Only noted here.

Affected Programs
Hull Design, Marine Drafting

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 26 of 517


Product Release Letter
Description
Marine Drafting – Treatment of invalid model subviews during Update Design

Description
In previous versions of Marine Drafting, model subviews without a valid DESI reference has been
deleted when Update Design is performed (via command prompt or any Drafting function updating a
model view). In Marine Drafting 12.1 SP4 it is now possible to control the behaviour: delete or preserve
with a warning.

For this purpose a new Drafting Default Keyword has been introduced.

Keyword:

UPDATE_DESIGN_CLEAR_INVALID_SUBVIEW

System default value:

“Yes”

Explanation:

When Update Design is performed (via command prompt or any Drafting function updating a
model view), model subviews without a valid DESI reference will either be deleted or
preserved.

Legal values:

"No” Invalid model subviews will be preserved with user notification


"Yes" Invalid model subviews will be deleted without user notification

Benefits
Possibility to control how to treat invalid model subviews during Update Design

Compatibility Constraints
None

For More Information


Only noted here.

Affected Programs
Hull Design, Marine Drafting

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 27 of 517


Product Release Letter
Description

Marine Drafting – Automatic Symbol Positioning in MarApi function symbol_new

Description
In Marine Drafting 12.1 SP4 Hotfix, the “Automatic Symbol Positioning” concept has been introduced in
MarApi function symbol_new (giving same behavior as in interactive function “Insert/Symbol”). Note
that this will change the behavior of symbol_new function when “Automatic Symbol Positioning” is
enabled.

Benefits
Improved functionality in symbol_new MarApi function

Compatibility Constraints
None

For More Information


See documentation of interactive function Insert/Symbol for details about “Automatic Symbol
Positioning”. Also see documentation of Drafting Default Keyword SYMB_AUT_LINE in User Guide
Marine Drafting / Appendices / Drafting Default File Keywords / Symbols.

Affected Programs
Hull Design, Marine Drafting

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 28 of 517


Product Release Letter
Description
Marine Drafting – Blanking Control when Creating Dimensionings

Description
In Marine Drafting 12.1 SP4 Hotfix, a blanking group (similar to the one in Label creation dialog) has
been incorporated in the following dimensioning dialogs:

- Linear 2D
- Radius
- Diameter
- Angle
- Linear 3D
- Axis Parallel

The blanking group contains:

A check button Blank Out, controlling whether model geometry obscured by the dimensioning should
be blanked-out (see Drafting default keyword DIM_AUTO_BLANKING)

A text field Margin, denoting the margin used when blanking-out (see Drafting default keyword
DIM_BLANKING_MARGIN)

For example, the dialog in Linear 2D dimensioning now looks like:

Note that “Advanced” and “Mould Line” buttons has been moved slightly to make room for the blanking
group.

Benefits
Convenient User interface for blanking control when creating a dimensioning.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 29 of 517


Product Release Letter
Compatibility Constraints
None

For More Information


Only noted here.

Affected Programs
Hull Design, Marine Drafting

12.1.SP4.37

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 30 of 517


Product Release Letter
Description
New Profile Endcuts

Description
A number of new profile end cut types have been added to the number of currently available.

The new end cut types are:

109, 53 and 54 for flat bars

78, 55 and 56 for bulb and L-bars

169, 170, 171, 51, 52 and 149 for T-bars

Please see sketches below

Benefits
Flexibility.

Compatibility Constraints
None.

For More Information


Please see User’s Guide.

Affected Programs
Hull Design.

For flat bars:


Type 109:

Code, parameters R1 R2

10910, a, b, [α1] 35 5
10920, a, b, [α1] 50 10

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 31 of 517


Product Release Letter
Type 53:

Code, parameters R1
5300, a, b, [α 1] 50
5310, a, b, [α1] 50
5320, a, b, [α1] 50
5330, a, b, [α 1] 50

Type 54:

Code, parameters R1 R2
5410, a, b, [c, α1] 30030 20045
5420, a, b, [c, α1] 30045 20030

Remark:
R1 1000*R1 + V1
R2 1000*R2 + V2

For bulb and L-bars:

Type 78:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 32 of 517


Product Release Letter

Code, parameters R1 R2 α2 α3

7800, a, b, c, [α1] 15 -10 90 90


7810, a, b, c, [α1] 35 -10 60 90
7820, a, b, c, [α1] 50 -10 30 60
7830, a, b, c, [α1] -10 -10 18 60

Type 55:

Code, parameters R1 α2
5500, a, b, [c, α1] 50 90
5510, a, b, [c, α1] 50 30
5520, a, b, [c, α1] 50 30
5530, a, b, [c, α 1] 50 18

Type 56:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 33 of 517


Product Release Letter

Code, parameters R1 R2
5610, a, b, [c, α1] 30030 20045
5620, a, b, [c, α1] 30045 20030

Remark:
R1 1000*R1 + V1
R2 1000*R2 + V2

For T-bars:

Type 169:

Code, parameters R1 R2 α2

16900, b, [α1] 0 10 18
16910, b, [α1] 35 10 18
16920, b, [α1] 50 10 18
16930, b, [α1] -10 10 18

Type 170:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 34 of 517


Product Release Letter

Code, parameters R1 R2 α2 α3

17000, b, c, [α1] 0 10 18 18
17010, b, c, [α1] 35 10 18 18
17020, b, c, [α1] 50 10 18 18
17030, b, c, [α1] -10 10 18 18

Type 171:

Code, parameters R1 R2 α2 α3

17100, a, b[, c, α1] 40 10 18 18


17110, a, b[, c, α1] 40 10 30 30

Type 51:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 35 of 517


Product Release Letter

Code, parameters R1 α2 α3
5100, a, b, [c, α1, α4] 50 90 90
5110, a, b, [c, α1, α4] 50 30 90
5120, a, b, [c, α1, α4] 50 30 30
5130, a, b, [c, α1, α4] 50 18 18

Type 52:

Code, parameters R1 R2
5210, a, b, [c, α1, α4] 30030 20045
5220, a, b, [c, α1, α4] 30045 20030

Type 149:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 36 of 517


Product Release Letter

Code, parameters R1 R2 α2 α3
14900, a[,b, c, α1, α2] 30 30 30 30
14910, a[,b, c, α1, α2] 20 60030 18 18
14920, a[,b, c, α1, α2] 15 80040 45 30
14930, a[,b, c, α1, α2] 30 80050 30 45

12.1.SP4.35:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 37 of 517


Product Release Letter
Description
Marine Drafting – Picking In 3D View

Description
The 3D view is available on both Hull Design/Outfitting Design and Marine Drafting/Outfitting Draft
modules. However when selecting an element in the 3D canvas the result is different in the design
modules compared to the draft/drafting modules. For example, when picking a flange on a pipe:
• In Hull Design/Outfitting design the flange will be selected in the 3D view and the flange will also
become the current element in the design explorer.
• In Marine Drafting/Outfitting Draft the whole pipe branch is selected and it is also the pipe branch
that will become the current element in the design explorer.
There has now been some improvements to support the “Design” picking mode in in Marine Drafting
and Outfitting Draft. Please note that the other way around is not possible: Design can only have design
picking mode.

In Marine Drafting this new picking option is controlled by a new Drafting default keyword
“VIEW3D_PICK_MODE“. It may be assigned to any of the two values:
1. Design - The picking mode should be “as in Design”. This is the only legal when you are in a
design module. When in marine drafting, this value can activate the “design” way of picking.
2. Drafting - The picking mode should be the default drafting mode. This is not a legal value working
in a design module.
(The pre-selected value of the default keyword depends on the module. In Marine Drafting it is
“Drafting” and in design it is “Design”)

In Outfitting Draft the design pick mode can be activated by unchecking the option “Draft Pick Mode”
that can be found in the menu “3D View\Settings”. This is only available when the 3D view is opened
and the setting will only apply to the current instance of the 3D view. (This is different to Marine Drafting
where all instances of the 3D view will apply to the current drafting default setting.)

Benefits
The drafting and design picking result is the same which can be less confusing for the user.

Compatibility Constraints
None.

For More Information


N/A

Affected Programs
Marine Drafting/Outfitting Draft

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 38 of 517


Product Release Letter
Description
Model Info

Description
New possibility to modify and customise the information presented in the “Model Info” window. This is
now also available for outfitting models, and the name of the indicated outfitting component is
presented in the information window. The PML object ModelInfo is available to use for the
customisation of the information. This includes adding and removing properties as well as editing
existing ones. The customisation is made using the PML Trigger function trigdraftmodelinfopre.pmlfnc
and the script is provided with this release, including an example customisation for some outfitting
models and thus changing the default behaviour of the “Model Info” function. If this is not wanted, the
script can be removed from the PMLLIB folder, and the only notable change is that the name of an
indicated outfitting component is presented in the information window, as described above.
Methods available on the ModelInfo PML object:
Name Result Purpose
DBREFGET() STRING The DB Reference of the
indicated object as a STRING.
ADDPROPERTY(STRING, REAL Add new property with title and
STRING) value given as STRING,
STRING. Return the allocated
property number.
REMOVEPROPERTY(REAL) REAL Remove given property number
(REAL), return the same value.
MODELINFOPROPERTIES() ARRAY Creates an ARRAY of the
currently available properties as
property numbers.
PROPERTYTITLE(REAL) STRING Get the property title as
STRING from input property
number as REAL.
PROPERTYVALUE(REAL) STRING Get the property value as
STRING from input property
number as REAL.
EDITPROPERTYTITLE(REAL, STRING Change the property title to
STRING) input STRING and property
number REAL. Return the new
title as STRING. The property
title needs to be unique.
EDITPROPERTYVALUE(REAL STRING Change the property value to
, STRING) input STRING and property
number REAL. Return the new
value as STRING.

Benefits
Improved possibility to modify and customize the information presented in the “Model Info” window, also
available for outfitting models.

Compatibility Constraints
None.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 39 of 517


Product Release Letter
For More Information
Draft > Marine Drafting > Drafting > Marine Drafting User Guide > Model Viewing and General Drafting
> Common Functions and Routines > Model Info

Affected Programs
AVEVA Marine Drafting

12.1.SP4.33

Description
Slicing of Hull Symbolic View

Description
Changed behaviour for slicing a Hull Symbolic View. Now it is possible to slice a Hull Symbolic View in
the sense that the depth before and behind the Hull Symbolic View plane are redefined according to
user input. The view is recreated once the method finishes.

Benefits
Improved meaning of slicing a Hull Symbolic View.

Compatibility Constraints
None.

For More Information


Draft > Marine Drafting > Drafting > Operators Instructions > Operators Instructions Drafting > TOOLS
> MODEL VIEW > SLICE

Affected Programs
AVEVA Marine Drafting

Description
Create RSO from Panel

Description
The existing function “Create RSO from Panel” is generating a RSO with geometry following an
indicated panel, but without any definition data. An alternative way of creating an RSO from a panel is
now available. This new function creates an RSO in the same plane as a selected panel and the limits
defined in the panel (if surfaces or RSOs) are used to limit the RSO where possible. The selected
envelope is used to create the final shape of the RSO. The new function is activated using “RSO
Sketch 2D” as shown in picture below.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 40 of 517


Product Release Letter

Benefits
The created RSO will get all definition data and can be updated and used as any other RSO.

Compatibility Constraints
None

For More Information


See User Guide Hull Structural Design / Functional Overview / RSO / Sketch 2D.

Affected Programs
Hull Structural Design

12.1.SP4.32

Description
Surface Manager Enhancements

Description
Some new rendering options have been added to the Surface Manager.

The rendering style Outline allows the user to draw only the bounding edges of the faces in a B-rep
model. Edges between two faces are coloured yellow, the remaining ones blue.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 41 of 517


Product Release Letter
When the option Show control points is enabled the control points/control polygon for each face in a B-
rep model are drawn.

When the option Show normals is enabled the normal of each face in a B-rep model is drawn.

Benefits
Better error detection and control of imported data

Compatibility Constraints
None.

For More Information


See the documentation.

Affected Programs
Surface Manager

Description
Marine Drafting – Defining owner in Multi-Select Copy function

Description
In Marine Drafting 12.1 SP4 Hotfix, the “Multi-Select” Copy function has been improved by letting the
user define the target owner for the copies.

In previous releases, the selected elements were always copied to the same owner as the source.

If the selection contains elements below view level, the system will now ask the user to indicate the
target owner for those elements:
• If a target owner is indicated by user, each element in the selection will then be copied
below appropriate level in that owner structure.
• By clicking “Operation Complete”, the same owner will be used. Each element will then
be copied within the same owner (default behaviour in previous releases).
• By clicking “Options”, a new owner view will be created. Each element will then be
copied below appropriate level in that owner structure.
Moreover, a check for model information within the selection is done in the same manner as in the
Modify/Copy/Subpicture function (the drafting default keyword
MODEL_SUBPICTURE_2DREGROUP_ALLOW is used to decide if model information should be
copied).

Benefits
Possibility to control what target owner to use in the Multi-Select Copy function

Compatibility Constraints
None

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 42 of 517


Product Release Letter
For More Information
Please see the Marine Drafting documentation of “Multiple Select in Drafting” in User’s Guide.

Affected Programs
Hull Design

Marine Drafting

Description
Marine Drafting – Multi-Selecting Drawing Reference information disabled

Description
In Marine Drafting 12.1 SP4 Hotfix, information belonging to drawing reference views will no longer be
possible for user to add to the multi-selection.

The reason is that such information should not be possible to modify.

Benefits
Information in drawing reference views is now protected

Compatibility Constraints
None

For More Information


Please see the Marine Drafting documentation “Multiple Select in Drafting” in User’s Guide.

Affected Programs
Hull Design

Marine Drafting

Description
Additional Defaults for Hull Position Number Function

Description
To be able to control the various check boxes in the Hull Position Number function, additional default
keywords has been added.

To control the Posno boxes:

POS_PRO_POS = <value>
POS_PLA_POS = <value>
POS_BRA_POS = <value>

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 43 of 517


Product Release Letter
POS_CLI_POS =<value>
POS_DOU_POS = <value>

And also an additional key word to control the Pro symb check box:

POS_PRO_PRO_SYMB = <value>

<value> can be either Y (check box is ticked) or N (check box is blank)

Note if all check boxes are set to N and all Symb is set to NONE, the system will present the Position
number of the part as if the Posno box is checked.

Benefits
Possible to define the start-up values for the different check boxes.

Compatibility Constraints
None.

For More Information


None.

Affected Programs
AVEVA Marine Hull applications

12.1.SP4.31

Description
Separate Knuckled Panel

Description
In the function Panel – Knuckled it is possible to make a knuckled panel from several normal panels.
The function has been enhanced to allow the user to indicate a main knuckled panel and (after a
question about it) get the subpanels separated into normal panels.

The panels will be placed in the same block as the main knuckled panel had and will also get the same
data type.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 44 of 517


Product Release Letter
The storing code for the panels will be retrieved as follows:

If the Main knuckled panel is defined as SBP, P or S the panels will get the same storing code.

If the panel is stored over centre line (SP) the panels will be checked if they are S, P or SP.

Benefits
An easy way to separate a knuckled panel.

Compatibility Constraints
None

For More Information


Refer to Hull Detailed Design -> Planar Modelling -> User’s Guide -> Interactive Planar Hull Modelling
Functions -> Model Generation and View Functions -> Panel -> Knuckled

Affected Programs
Hull Design

Description
New varying bevel types

Description
Three new bevel types are added. They are variants of already existing types with the only difference
that the nose is instead of being vertical height, it is parallel to the connection surface.
The three basic types are varying types 17, 39 and 49 and the new variations are 117, 139 and 149.
All parameters are the same as its original bevel type.
Bevel type 117

Bevel type 139

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 45 of 517


Product Release Letter

Bevel type 149

Benefits
Some yards measure the nose height parallel to the surface. With those new types, both variations of
nose height are available.

Compatibility Constraints
None.

For More Information


None.

Affected Programs
AVEVA Marine

Description
Marine Drafting – ”Depth of Analyse” in MarAPI function DwgPurge

Description

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 46 of 517


Product Release Letter
In Marine Drafting one optional parameter has been added to the MarAPI function DwgPurge (and
DwgPurgePML). The parameter “DepthOfAnalyse” controls the depth of analyse during purge. Highest
value (3) means best result while lowest value (1) means best performance.
Legal parameter values are:
1. View level
2. Subview level
3. Component level (default behavior)

Benefits
Possibility to speed up performance if necessary.

Compatibility Constraints
None

For More Information


Please see the Marine Drafting documentation of Vitesse functions:

• Dwg_purge

and corresponding MarAPI functions

• DwgPurge

Affected Programs
Hull Design
Marine Drafting

Description
Marine Drafting – MarAPI function DwgPurge vs 2d Restriction

Description
In Marine Drafting 12.1 SP4 Hotfix, one optional parameter has been added to the MarAPI function
DwgPurge (and DwgPurgePML).

The parameter “Preserve2DRestriction” controls if model subviews totally outside the 2d Restriction
Frame (and therefore empty) should be preserved or not.

Legal parameter values are:


0 No, remove model
1 Yes, keep empty model subviews (default behavior)

Benefits
Possibility to control how to handle model subviews, empty because totally outside the 2d restriction
frame of the view.

Compatibility Constraints
None

For More Information


Please see the Marine Drafting documentation of Vitesse functions:
• Dwg_purge

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 47 of 517


Product Release Letter
and corresponding MarAPI functions

• DwgPurge

Affected Programs
Hull Design
Marine Drafting

12.1.SP4.30:

Description
Marine Drafting – Selecting presentation by short-cut key in Dimension Layout dialog

Description
In Marine Drafting it is now possible to use keyboard keys 1-4 to select the wanted layout in the
Modify/Dimension/Presentation dialog

Benefits
Improved user interface

Compatibility Constraints
None

For More Information


None

Affected Programs
Hull Design
Marine Drafting

Description
Marine Drafting – Updating Note text

Description
In Marine Drafting, the Drafting default keyword DENY_UPDATE_OF_NON_PERSISTED_GEOM now
also controls the behavior when updating text belonging to a Note component.

When updating a text element belonging to a note component (not persisted in PADD, but still possible
to re-evaluate) the system can react in two ways:
• Allowing the update, keeping in mind that the modification will be lost at the time the Note is re-
evaluated (e.g. when moving the Note by Modify/Move/Reference)
• Deny the modification on geometry level but instead applying it on Note level (forcing a re-
evaluation of the whole Note) if this is possible

The system will apply the modification on Note level if and only if
• The text belongs to a Note component
• The modification makes sense on Note level
• This default keyword is set to YES

The text modifying functions that now trig the default keyword are:
• Edit/Text and Mouse Right-Click Text / Edit
• Modify/Move/Text and Mouse Right-Click Text / Move
• Modify/Properties/Text/Properties

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 48 of 517


Product Release Letter
• Modify/Properties/Text/Contents
• Mouse Right-Click Text / Properties

Note that in previous releases, the above mentioned functions always apply the modification on Note
level (as if default keyword is set to YES)

Benefits
Possibility to control the behaviour also when updating texts in Note components.

Compatibility Constraints
None

For More Information


Please see the Marine Drafting documentation of Drafting default keywords

Affected Programs
Hull Design
Marine Drafting

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 49 of 517


Product Release Letter
Description
Marine Drafting – MarAPI function DwgPurge vs Slice

Description
In Marine Drafting 12.1 SP4 Hotfix, an optional parameter has been added to the MarAPI function
DwgPurge (and DwgPurgePML). The parameter “PreserveSlice” controls if model subviews totally
outside slice planes (and therefore empty) should be preserved or not.

Legal parameter values are:


0 No, remove model
1 Yes, keep model (default behavior)

Benefits
Possibility to control how to handle model subviews, empty because totally outside slice planes (this
control is already implemented in the interactive function Tools/Inspect Drawing/Purge).

Compatibility Constraints
None

For More Information


Please see the Marine Drafting documentation of Vitesse function:

• Dwg_purge

and corresponding MarAPI function

• DwgPurge, DwgPurgePML

Affected Programs
Hull Design
Marine Drafting

Description
Marine Drafting – New MarAPI functions & new implementation of “Refresh” function in
Marine Drawing Explorer

Description
In Marine Drafting 12.1 SP4 Hotfix, five new MarAPI functions have been introduced. The functions are
used to identify elements in the Marine drawing, referring to a given element in PADD.

Moreover, the “Refresh” function in Marine Drawing Explorer has been re-implemented to clear the tree
view in order to force synchronization with the drawing. Once selected, the tree will now be collapsed.

Benefits
Convenient tools for finding the Marine Drawing element referring to a given element in PADD.
Expected behaviour in Marine Drawing Explorer “Refresh” function.

Compatibility Constraints
None

For More Information


Please see the Marine Drafting documentation of Vitesse functions:
• element_identify_by_padd_dbref

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 50 of 517


Product Release Letter
• view_identify_by_padd_dbref
• subview_identify_by_padd_dbref
• component_identify_by_padd_dbref
• geometry_identify_by_padd_dbref

and corresponding MarAPI functions


• ElementIdentifyByPaddDbRef
• ViewIdentifyByPaddDbRef
• SubviewIdentifyByPaddDbRef
• ComponentIdentifyByPaddDbRef
• GeometryIdentifyByPaddDbRef

Affected Programs
Hull Design
Marine Drafting

Description
Placing Components at a Selected Snap Point

In addition to the place3D button on the component editor form the place in line functionality has been
extended to use any graphical feature as a positioning point.

Previously the user would need to pick the appropriate tube element in which to insert components and
the components would be positioned at the exact picked position along the tube. This functionality still
works as before, but now it is possible to pick any item as a positioning point using graphical tools.

The next two views show the current situation where the user picks a component position in tube and
the component is placed accordingly.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 51 of 517


Product Release Letter

The following shows the result of picking an alternate design element. This time it is necessary to pick
the insert component so that the system knows which tube to insert into so now we are positioned at
the elbow.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 52 of 517


Product Release Letter

Here a pline of the section is selected.

The component is placed in line with the section.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 53 of 517


Product Release Letter
It is now possible to extend the current tube by selecting an item outside the current tube length. Here
we are selecting the next section along, to place another tee.

The system now asks if it is ok to extend the tube. If you answer yes, the component is positioned as
requested. If you answer no, the tee will be deleted.

Description
Disable NSBC Detail Plot production (SI-79862, SI-80769)

The TEXTPOSITION command has been enhanced to allow the production of Non-Standard Branch
Connection detail plots to be disabled :-

TextPosition DetailPlots ON NSBCOFF

This option may be set via the Detail Plots Options form :-

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 54 of 517


Product Release Letter

ISODRAFT Allow AWELDs to be displayed in boxes (SI-86218)

The WELDNUMBERS command has been extended to allow Additional Welds to be displayed in boxes
(for example) :-

WELDNUMBERS CHARHEIGHT 2.1mm ALL FROMDB AWELDS BOXES 4

This option may be set via the Weld Numbering Options form :-

12.1.SP4.29

Description
New Pipe Settings Form Added
Piping Settings/Defaults
The main purpose of the new pipe settings form is to add control of how Pipe tappings are used but it
also includes basic default settings for the component creation form and tube insertion values which
can now use Datacon tube ranges.

The new form can be controlled or uncontrolled depending on the project requirements. If the form is
controlled, the form will be read only for normal users displayed for reference only. If it is controlled it
can be accessed by designated users and free users

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 55 of 517


Product Release Letter
The actual trigger for enabling the control to be read only will be the existence of a team called
PIPINGADMIN in the project. When the settings are first loaded the initialisation will check for the
existence of the PIPINGADMIN team and load the file from the projects defaults area. If a settings file
does not exist in the project area it will create one with default settings. This will be read only for normal
users but can be changed by any member of the PIPINGADMIN team or any free user.
The file for controlled piping defaults will be put in the PDMSDFLTS area as:
'%PDMSDFLTS%/piping_settings_General'

Where the piping defaults form is uncontrolled the piping defaults file will be in the PDMSUSER area
and there will be a RW file for each user in the form:
'%AVEVA_DESIGN_USER%/piping_settings_Username

The Piping settings form has two main areas, the component creation and Non Standard Branch
connections.
The component creation area contains some settings which were once stored in a file in the
PDMSUSER area with a name component creation_<username>. This file is now superseded by a new
file with a name piping settings_<username> which contains more user preferences.

Controlling the Insert Tube Length for Component Creation

When a component is inserted into tube in the Component Creation form there is a process which
determines where the component will be inserted. Basically two values are considered; Snap Distance
and Minimum Tube length.
If the picked position is less than the current Snap distance away from a component the process will try
to connect to the previous component. The minimum tube distance can be different to the snap
distance and works to ensure that the minimum tube between welds is a practical value. Unfortunately
Snap and Minimum Tube values are single values and the default is 100mm.
There is another way of setting these values by introducing a factor for example 2 times the outside
diameter with a text of “2 * OD’ for snap Distance and/or Min Tube Length.
Neither option is ideal because one provides a single value for all sizes and the multiple method
provides an odd length on which to base a measurement.
For this development two extra fields have been added to provide a means of using pre-set Datacon
tube lengths based on bore size.
Previously Snap Dist and Min.Tube these values were stored in a user defaults file but now they are set
using the piping settings form as shown below. Both values can be a value or a bore based expression
as shown:

This view shows examples of the old methods

This method shows the Datacon options set.


The default Datacon tolerance is a simple 100mm for everything but it can have different values for up
to 10 bore ranges.
If you have tube tolerances set, the command Q TOL TUBE will show you what they are.
Here is a sample:
Minimum tube length :100mm
Minimum tube length :75mm for Bores from 10mm to 65mm
Minimum tube length :100mm for Bores from 80mm to 200mm
Minimum tube length :200mm for Bores from 250mm to 600mm

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 56 of 517


Product Release Letter
Minimum tube length :300mm for Bores from 600mm to 1200mm

Any tube bores not covered by the ranges will get the default 100mm tolerance

The mid part of the form relates to settings on the component creation form itself and simply define how
the form is first displayed. Auto align, Auto Create, Select Adjacent Out of Spec and Skip Connected
Comps will all appear as defined by these default settings. However once the form is in use during a
design session the defaults will not be applied again.
The Descriptions pulldown controls how the component creation form displays component choice.

The Full option displays a combination of Catalogue texts - STYPE, RTEXT and MTXX. For example:

The other options are cut down versions:


R Text

Note in the example below S text, T Text and Catalogue Reference the tables are the same because
there are no values set in the standard catalogue for STEXT and TTEXT and the default is to use the
catalogue reference if no other value can be found.

The Non Standard Branch defaults area contains some options to configure where and how NSBC
connections may be made.
How NSBC connections are used are controlled by the Non Standard Branch Connections box on the
piping Settings form

The options are shown below:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 57 of 517


Product Release Letter
The Not Allowed option restricts NSBC completely if the user ties to create a connect ion the following
massage is displayed:

The From Specification option means that NSBC connections are available on pipes whose PSPEC
has reference to a tapping table and the current bore size is valid. If a user tries to select a pipe which
does not have a valid tapping spec, the following is displayed:

The No Restriction option, as the title suggests, allows any combination on any pipe with no
restrictions.
The final option allows you to use a tapping table. Although only one table is shown in the list, it will
show all of the tables available and allow you to select any one.
If multiple tables are in use, it’s probably better to assign them to the piping specs using the tap
reference attribute.
The final option is the Not Allowed in Tube toggle. Ticking this prevents NSBC connections from being
used in tube, thus forcing the user to use conventional tees or olets from the piping spec.

Description
Project Data updates
In order to enable the control of tappings and part of a bug fix, there is a macro which needs to be run
into the MAS project before this development will work properly. The is located in:
Data12.1.SP4\pdmsui\DFLTS\data\SP4Update\Update.pmldat
To run this, go to Paragon in the MAS project with mdb /ALLMAS
If the macro is located in the correct place it can be run by:
CALLDEF data\SP4Update\Update.pmldat from the Paragon module
Note this macro creates a new tapping table then goes to Propcon to create some weights, the returns
to Paragon to finish. If everything loads ok savework and go to design.
The SP4Update directory is contained in a zip file which will be supplied.

Description
New 3-D Component Creation Button
Traditionally there have been two methods for inserting components into a branch, connect and place.
Both methods insert new components into an existing pipe route but always in line with the current
constrained centreline. For this development a new insertion method has been introduced (Place3D) to
allow a new component to be inserted using the event driven graphics picking mechanism.
This works by inserting a new component after the current element in the branch but its position is
determined by an event driven pick. The actual position can be derived by any of the EDG pick options
and the component is placed at the picked Position. At this point the model editor is invoked to allow
further position adjustment.
Below is an example of placing a valve:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 58 of 517


Product Release Letter

Description
Changes to Non-Standard Branch Connection functionality
When creating branches using NSBC the user was not able to change the bore size after fixing the
position. This was an unnecessary restriction and has now been removed. Additionally the bore size
option is moved to the top of the panel to improve workflow and make it more noticeable. The forms
changes are shown below:

The old layout

The new layout

As well as the changes to the Layout, you can now change the size of an unconnected branch
providing it has no components. Connection options and insert depths are re calculated to suit.

Description
Pipe Tapping Tables in Paragon

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 59 of 517


Product Release Letter
A pipe tapping table is a new table type for use with Non-Standard Branch Connections(NSBC)NSBC
connections have 5 specific types which are identified by the following codes:
The types are:
STU = Insert Connection
SSU = Surface Connection
SSA = Saddle Connection
SEX = Extrusion Connection – Where the main tube is extruded to form a dome for welding
TAP = Boss/olet/half coupling from the current spec

The Tapping Table lists combinations codes and bore sizes to control which options are available at
specific bores. A practical table called /TAPPINGS-Default-Table is included in the data section of this
release and provides an example of the size ranges often used.

A new tapping table is created via the branch table functionality and is achieved by creating a table with
the PURPOSE of PTAP

The Table form looks like this:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 60 of 517


Product Release Letter

New values can be pasted into multiple rows and columns using select and paste.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 61 of 517


Product Release Letter
Description

Changes to Quick Pipe Router Bend selection

When using the quick pipe router it is possible to either use elbows, or bends for changing pipe
direction. Quick Pipe Router used to apply a default radius to bends if it could not find a suitable radius
from the specification.
Now the user has a choice of how bend radius is calculated based on a new bend radius selection
form. This can be initiated by right clicking on the quick pipe router direction handle or it appears
automatically if Quick Pipe Router cannot find a default.
To select bends in Quick Pipe Router, select Component Choice then Use Bends

If the bend radius has been set in the specification, then this radius will always be used.
If you select use bends and there is no radius set in the specification, then you have the option to set a
bending machine or a defined radius.
If neither of them are set when you select use bends, the default radius selection form will show
automatically.

New screenshot
At the top of the form, the current creation options are shown. This shows you the branch that the quick
pipe router is modifying.
If the form is being displayed when using the specification, the form will be entirely greyed out when
opened and it will specify that it is using a specification at the top of the form.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 62 of 517


Product Release Letter
Also at the top of the form there are two options for the user to select whether they want the quick pipe
router to try and use a bending machine, or use a defined radius.
Clicking on these options will grey out irrelevant gadgets on the form.

Bending Machine
If the user selects bending machine, then the bending machine options will be made available.

Within the drop down box is the complete list of bending machines that are available in the MDB.
It is possible to set either a bending machine, a bending machine group, or a bending machine world.
You can set the bending machine at either branch, pipe or zone level.
When the bending machine is set, the bending machine is first validated against the current branch, if
the bending machine cannot be used on the current branch, the user is asked if they wish to proceed.

If the user clicks no, the bending machine is not set and the form closes. If the user clicks yes, the
bending machine is set at the level selected on the form.
The quick pipe router will always use the bending machine that is set at the lowest level,
e.g. BRAN > PIPE > ZONE
If the user attempts to set the bending machine at an upper level, e.g. PIPE, then a check will be done
to see if a different bending machine has been set at the branch. If it has the user will be asked if they
wish to remove the bending machine at the lower level.

It is also possible to unset the bending machine at a particular level by selecting unset from the drop
down list.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 63 of 517


Product Release Letter
Default Radius
Setting the form to Default Radius will activate the default radius options.
It is possible to either set the default radius to a multiple of the outside diameter. Or set the radius as a
user defined value.

12.1.SP4.28

Description
Naming and Colour Rules Enhancement (SI 59072, 59073, 59074)
Naming Rules
Naming rules are critical on a project, and access to change rules that could change element naming
should be restricted to users with certain privileges. This is already implemented for Autonaming rules
on the Naming Settings form, where users without Administration privileges are not permitted to open
the Define Rules form.
Users with access to change Naming Rules:
• Any Free user
• Any user in MASTER team or a team with name <Module Key>ADMIN, e.g. DESADMIN.
• In Paragon - users belonging to team CATADMIN
• In Draft - users belonging to team DRAFTADMIN

Autocolour Rules
Element colouring rules are not as critical as naming rules on some projects, depending on project
working practices. Ordinary users (i.e. users not in an ADMIN team) may be permitted to change colour
rules.
The problem highlighted is that Element Rules are stored in PDMSUSER or project defaults or system
defaults folders under the name MARODES-ELEMENT-RULES.PMLDAT (in Marine). This file can be
modified from the Naming Rules GUI only if logged in as an ADMIN user. However, this same file can
be modified from the Auto Colour Rules GUI by a user without ADMIN privileges. The same level of
ADMIN protection to the Element Rules file when modifying Auto Colour Rules and Naming Rules is
requested.

Naming and Colour Rule Files


When loading Naming or Colour rules the system will search for the rule definition files in the following
order:
1. User folder (%PDMSUSER%)
2. Project defaults folder (%<Project ID>DFLTS%)
3. System defaults folder (%PDMSDFLTS%)
The first such file found will be opened, and this is the file that will be changed if the rules are saved.

Resolution SI 59074: Restrict Access to Element Rules from the Auto Colour Setting Form

Access is still available to all users to add or modify auto-colour rules, but access to the Element Rules
is restricted. [Note that some existing 12.1.SP4 Marine and Plant users who are currently able to
modify their Auto Colour rules and Element rules will have restricted access following this hot-
fix.]
From the Auto Colour Rules form, any user can still show the Element Rules form. They need to be
able to see the details of each Element Rule so that they can judge whether the rule is useful to be
used as part of an Auto Colour rule definition.
On the element rules form they can still add new rules, but they can only add them to their own
PDMSUSER area. They cannot modify or add to project or company rules. They cannot override
company or project rules with a local version of a rule because rule names cannot be duplicated.
For a user without administration privileges the option to save Element Rules to any location other than
PDMSUSER is denied.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 64 of 517


Product Release Letter

The Naming rules user interface is unchanged for SI 59074.

Resolution SI 59073: Store Auto Colour rules to Defaults from the Auto Colour Setting Form

The requirement is to be able to store changes back to the Colour Rules file that was opened.
Currently, opening the PDMSDFLTS file to edit colour rules writes the result back to PDMSUSER. Then
the user has to manually copy the file to the project defaults folder or to the system defaults folder. It
can be argued that it is good practice to encourage new rules to be checked locally before being shared
with other users.
The changes made to meet this requirement are as follows:
A new paragraph has been added to the Graphics Settings form Colour tab to indicate which set of
rules had been opened (User defined, Project defined or System defined):

Any user opening colour rules in PDMSUSER will be allowed to store changes back to PDMSUSER.
A user without Administration privileges can open a project or system defined colour rules file, but
cannot overwrite it, so they will be prompted to ask if they want to save their changes to PDMSUSER.
A user with Administration privileges can open a project or system colour rules file and store changes
back to that file if:
• They have write access to the file
• They have not use locally stored Element Rules in their colour rules, because these rules might
not be accessible by other users.
In both cases a warning message will be issued, and the user given the opportunity to save their
changes to their PDMSUSER folder.

Resolution SI 59072: Store Auto Naming rules to Defaults from the Auto Naming Setting Form

The requirement is to be able to store changes back to the Naming Rules file that was opened.
Currently, modified naming rules loaded from a system or project naming rules file are written back to
PDMSUSER. Then the user has to manually copy the file to the project or system defaults folder. It can
be argued that it is good practice to encourage new rules to be checked locally before being shared
with other users.
The changes made to meet this requirement are as follows:
A new paragraph has been added to the Naming Settings form to indicate which set of rules has been
opened (User defined, Project defined or System defined):

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 65 of 517


Product Release Letter

Only users with Administration privileges can proceed to the Define Naming Rules form, so there is no
change in behaviour for most users. Only users with Administration privileges can use the File > Save
command on the File menu.
A user with Administration privileges can open a system or project naming rules file, and store changes
back to that file if:
• They have write access to the file
• They have not used locally stored element rules in their naming rules, because these rules
might not be accessible to other users.
In both cases a warning message will be issued, and the user given the opportunity to save their
changes to their PDMSUSER folder.

12.1.SP4.26

Description
Marine Drafting – Transforming Model Subviews

Description
In Marine Drafting 12.1 SP4 Hotfix, a new function Tools/Model/Transform has been introduced. The
function is used to transform model subviews, where the “high design” level is controlled by the default
keyword AUTO_OUTFITTING_LEVEL.

Benefits
Improved control of Outfitting “definition level” when transforming model subviews

Compatibility Constraints
None

For More Information


Please see the Marine Drafting documentation of:
ng default keyword AUTO_OUTFITTING_LEVEL
ng function Tools/Model/Transform

Affected Programs
Hull Design, Marine Drafting

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 66 of 517


Product Release Letter

Description
Marine Drafting – Sectioning of Models in “Wireline Hidden Line” View Type

Description
There has been a changed in how model views with section planes (VSEC elements) are handled in
12.1.SP4.26. Previously the view type “wireline hidden line” meant that no sectioning was performed at
all on Outfitting Models, i.e. the whole model was presented, disregarding if it was inside or outside the
sectioning planes.

Typically Hull Symbolic Views will have section planes where the planes are created automatically to
map the limits defined for the symbolic view. There will also be section planes if the Marine Drafting
function Tools\Model View\Slice have been used.

In Marine Drafting/Hull Design the change will primarily affect Outfitting Models and assemblies. Hull
models have sometimes a “slicing” functionality of its own applied:

• In hull symbolic views

• When the view type is not global hidden line or universal hidden line

In Outfitting Draft all models are affected.

If sectioning is not desired on the view, the view type used should be “wireline” or the section planes
should be removed.

Benefits
Better performance when creating sliced/sectioned model views compared to the use of view type
“modelled wireline” which is slower.

Compatibility Constraints
None.

For More Information


N/A

Affected Programs
Marine Drafting/Hull Design/Outfitting Draft

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 67 of 517


Product Release Letter
Description
Flexible Templates – New word for the control information file.

Description
By using the new word “PINS_OUTSIDE_PLATE,<Number Of Pins>,” it’s now possible to define the
number of pin heights that will be added to table of pin heights list that is outside the plate on each side.

Examples:

PINS_OUTSIDE_PLATE,1, = ”This will give one pin height outside plate edge on each side of plate”

PINS_OUTSIDE_PLATE,0, = “This will only add pin heights that are located on the plate to the table of
pin heights list”

Benefits
User can remove unnecessary pin heights from table of pin heights list

Compatibility Constraints
None

For More Information


See User Guide Hull Detailed Design -> Manufacturing -> Curved Plates -> Flexible Templates ->
Control Information

Affected Programs
Bending Template Application

Description
Improved Cutout Welding Control

Description
The existing environment variable SBH_CUTOUT_TIGHT specifies a tolerance to be used when
checking whether a part of a cutout should be welded against a profile or not. There has been a
demand for being able to specify this tolerance for the web and flange part of the profile individually.

Two new environment variables have been added:

SBH_CUTOUT_TIGHT_WEB defines the maximum distance between the cutout and the web part of
the profile, when the cutout is welded against the profile web.

SBH_CUTOUT_TIGHT_FLA specifies the corresponding maximum distance between the cutout and
the profile flange, when the cutout is welded against the profile flange.

Benefits
Flexibility.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 68 of 517


Product Release Letter
Compatibility Constraints
None.

For More Information


Only noted here.

Affected Programs
Hull Design.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 69 of 517


Product Release Letter
12.1.SP4.25

Description
Pipe Fabrication - User Feed Excess Form Feedback Required (SI 64096)

The Feed Excess form that allows the user to set the User Feed Excess between two bends now
provide a feedback of the current Grip length.
This is obtained from the Bend Mac Ref that is currently set.
This will just be text on the form and supplied as guidance because often when feed excess added it
does not necessarily have to be the same as the Grip dimension.
See attached screen shot suggestion. The actual wording is:-
'Current Grip = 150.0mm'
In the event that no Bend Mac Ref is set the value states 'unset'.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 70 of 517


Product Release Letter
Description

Pick up 2D view projection from 3D view in Marine Drafting (SI 66875)


The enhancement has been resolved by the addition of a new toggle option 'Direction' , which has the
tooltip 'Set 2D View Direct. The default is for this option to be OFF.
When ON, the direction of the 3D View is used to set the 2D View Direction.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 71 of 517


Product Release Letter
Description

IsoDraft – Ability to Control Pipe Fabrication generated Pspool Names


tagged on an Isometric (SI 79752)

The 12.1.SP4.25 Fix Release includes an IsoDraft enhancement that allows control of the Pipe
Fabrication generated Pspool Names tagged on an isometric.

ISODRAFT Pspool Names

The Pspool Name parameters may be set via the Material List Options form :-

This invokes the following command to tag the isometric with the section of the Pspool Name after the
3rd hyphen delimiter :-

PSNAME ON AFTER 3 '-'

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 72 of 517


Product Release Letter
Description
Diagrams – Replace background in Batch Mode (SI 58711)

1. Screen from “Diagrams->Utilities->Batch Job” dialog replaced by new one:

2. Screen from ”Diagrams->Utilities->Batch Job->Batch Update->Overview” (Figure 10:1


Batch job form) replaced by new one:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 73 of 517


Product Release Letter

3. Screen from “Diagrams->Utilities->Publishing Data to AVEVA NET-> Availability of


Publishing Function” (Picture from point 3 where “Batch Job dialog is presented) replaced
by new one:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 74 of 517


Product Release Letter

12.1.SP4.23

Description

Compare/Update Changes in 12.1.SP4 Fix.23


Compare/Update has had a major update in this release to align its functionality with AVEVA
Engineering 14.1.SP1 and Aveva Diagrams 14.1 and thus support integrated projects.

Taking Source Data from the AVEVA Integration Services


Compare/Update has the option to take source data from the new AVEVA Integration Services. This
service can be configured to access data from AVEVA Instrumentation, Electrical and P&ID, thus

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 75 of 517


Product Release Letter
allowing access to those products’ data without the need to have them installed on the same computer.
In the Configuration Wizard a new option to use Service Mode has been introduced.

Set Mode to Local if the source data is to be from a product installed on the same computer.

Set Mode to Service if the source data is to be from the AVEVA Integration Services. The window
changes to show fields for Server Name, Port and Source. These should be set according to the
Service configuration.

AVEVA Integration Services is available as a separate install. For more information refer to its
Installation and User Guides.

Multiple Configurations with the Same Source and Destination Types


The earlier restriction of a single configuration for any given combination of source and destination type
has been removed. This means it is now possible to define multiple configurations to cover different
subsets or attribute selections of the same types, or to allow configuration with and without member
hierarchies.

Compare Parent/Child Hierarchy


Compare/Update can compare a parent/child hierarchy, such as equipment and nozzles. Each level of
the hierarchy is controlled by a separate configuration. A step in the Configuration Wizard allows child
configurations to be included with a parent.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 76 of 517


Product Release Letter

Where the comparison includes a parent/child hierarchy, individual levels can be expanded or
collapsed by clicking on the "+" and "-" cells.

Import of Instruments to Instrument, Equipment and SubEquipment


Compare/Update now supports compare and import of Instruments from AVEVA Instrumentation to
Design element types Instrument, Equipment and SubEquipment. This gives the capability, for
example, to separate instruments into inline, offline mounted, and offline non-mounted.

Note: The integration UDA pmg-design-ai should have its element list extended to include types
Cable, Equipment, Instrument and SubEquipment.

Groups of Configurations
Compare/Update can now run a group of configurations as a single operation. The Administrator can
define groups of configurations using the new Manage Groups option.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 77 of 517


Product Release Letter

The Manage Groups form can be used to create groups and allocate configurations to those groups.

A configuration can be in more than one group. A setting on the Define Rule Set page of the
Configuration Wizard allows the administrator to define if a configuration can be run standalone.

Unless Make this Configuration standalone is checked, the configuration can be run only as part of a
group. Configurations set to be available standalone may also be in groups.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 78 of 517


Product Release Letter
The end user will see a combined list of the groups and those configurations that have been made
available standalone. When comparing, the results will be shown concatenated from each configuration
in the group in turn. When updating, a separate owner may be entered for each configuration in the
group.

Owner Expression Step in Configuration Wizard


A step in the Configuration Wizard allows an optional Owner Expression to be entered. This will be
evaluated against the appropriate source object during the Update Database process to determine the
owner for an inserted object.

The expression can be tested by selecting an object of the appropriate source type and pressing the
Test button.

During the Update Database process, the precedence of determining the owner for an inserted object
will be:
1. From the parent/child hierarchy if updating using a child configuration
2. From a PML callback if defined
3. From the owner expression if defined
4. From the setting in the Update Database dialogue

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 79 of 517


Product Release Letter
Allow Update Setting for Attributes
Attribute mapping may be restricted to comparison only. Each attribute has its own setting to Allow
Update.

Update Database dialogue more compact


The Update Database dialogue now hides sections not relevant to the current results. For example if
there are only unmatched items to be inserted, it will hide the section for linked or matched items to be
updated.

New “Accept All” Options


Where a Fluent UI is available, the options to accept objects for update have been expanded:
• Accept All Displayed accepts all displayed rows and is used to insert new objects and update
attribute values.
• Accept All Linked accepts all linked objects and is useful in order to unlink.
• Accept All Matched accepts all matched objects and is useful to link objects and/or update
attribute values.
• Accept All Unmatched accepts all unmatched objects and is useful to insert new objects.
• Accept None clears the current acceptance selection.

Note that the older UI style retains the simple Accept All button.

The PML methods have been expanded to be consistent with the accept options:
• acceptAllDisplayed() accepts all available changes.
• acceptAllLinked() accepts all linked objects.
• acceptAllMatched() accepts all matched objects.
• acceptAllUnmatched() accepts all unmatched objects.
• updateLink() now updates attributes for linked objects for consistency with the Update
Database dialogue default settings.

Note: Existing macros require modification


• An Accept method is now required prior to an Update in PML. Previously there was an implicit
acceptance of available changes. This is no longer the case.
• The acceptAllLink() method has been renamed to acceptAllLinked() for consistency with the
User Interface.

PML Callbacks

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 80 of 517


Product Release Letter
Specific company and project customisations can be implemented using PML callbacks and a
framework is provided for this purpose. Methods are provided in the cuProjectHandler PML object to
enable additional checks and actions:

• Switch PML events on or off


• Switch debug mode on or off
• Perform checks before starting the comparison; can abort the whole run
• Perform checks before comparing each object; can skip that object
• Carry out actions after comparing each object
• Carry out actions at the end of the comparison; save comparison results grid to file
• Perform checks before starting the update; can abort the whole update
• Perform checks before updating each object; can skip that object; can set an owner for inserted
object to override the owner from the Update dialogue
• Carry out actions after updating each object
• Carry out actions at the end of the update; save update results grid to file

Upgrading from earlier versions


Configurations from earlier versions of Compare/Update require upgrade. A member of team
CUADMIN can trigger an automatic upgrade by opening the Options dialogue. If upgrades are available
a prompt will be displayed to proceed. Once completed a log file will be displayed. This file is stored in
the folder CUConfigs2.0 under the project defaults folder. It will list which configurations have been
upgraded or skipped, along with any warnings.

The upgrade will not overwrite any configurations already defined in the later version. It will first
upgrade available configurations from Engineering 14.1 and then from earlier versions of 12.1.SP4.
Note that configurations with source AVEVA P&ID will require a service port number to be added
manually.

Further Information
For more information refer to the Compare/Update User Guide.

Description

ISODRAFT Express Bend Radius in multiples of Outside Diameter (SI-78706)

The BENDRADIUS command has been extended to allow the Bend Radius to be expressed in
multiples of the Outside Diameter :-

BENDRADIUS OUTDIAM

This option may be set via the Dimensioning Options form :-

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 81 of 517


Product Release Letter

Description

ISODRAFT Bill Of Material Gridlines (SI70833)

The MATERIALLIST command has been extended to allow the User to switch the ISODRAFT Bill Of
Material Gridlines to be ON or OFF e.g.:-

MATERIALLIST GRIDLINES ON/OFF

This may be accomplished via the Material List Column Definitions Options form :-

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 82 of 517


Product Release Letter
Example with MATERIALLIST GRIDLINES ON: -

Same example with MATERIALLIST GRIDLINES OFF: -

12.1.SP4.22

Description

FEM – MAESTRO MNF File Export

Description

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 83 of 517


Product Release Letter
A new export option has been added to export nodes and elements together with material and element
properties from FE models as MAESTRO files (MNF) which can be imported by the FEA software
MAESTRO.

The export function is available from Analysis | Export FE Model to MAESTRO MNF.

Compatibility Constraints

None
Affected Programs

Hull Structural Design

Description

HULL DESIGN – Stable multi face RSO reference


Description

In a case where a boundary limit is defined as a reference to an RSO face that face is supposed to be
adjacent to the face of the same RSO defining the panel plane.

However if the RSO is modified it may be that the faces are renumbered and limits defined this way
may get the wrong face number reference giving unpredictable results when regenerating.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 84 of 517


Product Release Letter
The solution is similar to the one for panel plane by RSO face. By giving an axis aligned ray (point)
intersecting the panel plane close to the midpoint of the boundary limit a stable reference to the face
can be created.

A coordinate pair in the global coordinate system is given, either (X,Y) or (X,Z) or (Y,Z). These
coordinate pairs will geometrically describe a ray in space. From the intersection between this ray and
the panel plane a point is created that is compared with the RSO face limits defining the panel plane.
Provided that the closest face limit is common to another face, this face is the chosen to form the
boundary limit.

From now on the system will automatically update the boundary definition provided the panel plane is
defined via an RSO face number on a multi face RSO. When storing the panel a ray definition will be
created and added to the boundary definition. The direct face number will be kept as information, but
the ray will take precedence.

At storing, if the face number is out of date it will be updated from the ray. Single face RSOs are not
affected by this development.
Benefits

Boundary limits defined by an RSO face reference will be insensitive to RSO face renumbering.
Compatibility Constraints

None.
Affected Programs

Hull Design

Description

Marine Drafting – Copy Drawings


Description

There is a new function in the File\Databank menu, “Copy Drawings”. This function can be used to copy
drawings within a project. The drawings will be copied to a specific location pointed out by the user, for
example to a DEPT or a REGI in another database. Normally when you create new drawings in Marine
Drafting they will be automatically placed in a REGI depending on the drawing type and the project
setup. This handling is overridden by this “Copy Drawings” function.

The function can be run interactively or started as a batch job, the latter is recommended for many
drawings or big drawings since the copy function can be a rather heavy operation.
For a complete description please refer to the attachment provided in the Knowledge Base Item 5350 in
AVEVA Helpdesk. Updated user documentation will follow in the next 12.1.SP4 User Documentation
release.

Benefits

Possibility to copy drawings to a specific location for example in another database.

Compatibility Constraints

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 85 of 517


Product Release Letter
None.

Description

Fabrication support of Bocad Models


Description

The Hull production software has been updated to allow manufacturing of plates and profiles released
into the manufacturing database from Bocad 3D. The following updates are made in Hull:
• Plates and profiles are allowed to be stored with names containing both upper and lower case
characters. PPI and related dialogues are changed accordingly
• The PPI dialogue is updated allowing selection from the work packages available in the
manufacturing database.
• Profiles in the manufacturing database can be stored without a marine end cut code, but
instead with the end cut geometry and significant parameters. The specific information will be
used and transferred into relevant document such as sketches and generic files.
• Plates and profiles in the manufacturing database can be stored without a marine specific bevel
code for edge preparation, but instead with the significant parameters describing the bevel. The
specific information will be transferred into relevant documents used for manufacturing.
• Holes and notches can now exist also on flanges of profiles. Furthermore, holes can be
described as drilled, threaded and sink.
• Profile sketches can be customized to display also the flanges of a profile in orthographic
projections

Benefits

A possibility to use the same manufacturing process for both marine and structural models.

Compatibility Constraints

If old input files with manufacturing part names given with lower-case characters are used, then these
needs to be updated with correct names.

Affected Programs

Hull Detail Design

Description

RSO with Complex Geometry


Description

Hull Structural Design has been updated to better handle complex shapes. The user can now decide if
RSO faces shall be made planar and allow the automatic generation of the RSO geometry to subdivide
faces where it is needed. Furthermore, the process to make faces planar is made in a way that points
are moved only in the direction given by the rows in the shape definition. If this is not geometrically
possible, the sub-division of faces will take place.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 86 of 517


Product Release Letter
Picture below is from the RSO Edit dialogue with the new Make Planar option.

Benefits

Simplified RSO geometry definition

Compatibility Constraints

The geometry of recreated RSOs with complex geometry may change to better follow the definition
data given by the user

Affected Programs

Hull Structural Design

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 87 of 517


Product Release Letter
Description

ISODRAFT Continuation Notes (SI-59447)

The CONTNOTES command has been extended to allow the value of a Pipe UDA to be included in the
Continuation Notes e.g. :-

CONTNOTES PIPE DESCRIPTIONS ON :MTOREF

The Pipe UDA may be set via the Annotation Options form :-

ISODRAFT Spec Break suppression (SI-46031, SI-48230)

New attribute IGNBRK has been added to the SPEC element in order to control Spec Break tagging on
an isometric.

The IGNBRK attribute should be set to true to suppress the Spec Break tag.

Description

Marine Drafting – Open Drawing, list “General Drawing”

Description
Before when listing “General drawings” in the “Open Drawing” dialog you could get a long list of
elements that are not “”true” General drawings. The reason for that is that also drawings with an
undefined Marine drawing type were listed under “General drawing”. These were typically drawings
generated via Outfitting Draft. In more detail it meant that SHEET elements with attribute
MARPTYPE 1 (General drawing) or 0 (Outfitting Draft generated drawing)

This has now changed. The system will only list SHEET elements where the attribute
MARPTYPE=1 under “General drawing” .

In case you still what to access the “Outfitting Draft” generated drawings (with MARPTYPE=0) you
will now have to use the “All Drawings” option, preferably with a name filter since “All Drawings” will
list any SHEET element in the MDB disregarding of drawing type.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 88 of 517


Product Release Letter

Benefits
It is easier to list all general drawings without disturbance from “Outfitting Draft” generated
drawings.

Compatibility Constraints
None.

For More Information

N/A

Affected Programs
Marine Drafting/Hull Design

12.1.SP4.21

Description

UI Changes to Find Utility

1. The “Element Type” text area used to be prepopulated with “[ALL]” which allows the user to search
for all element types. This has been removed to try and discourage this kind of search, but it is still
possible to do by selecting it or typing it in.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 89 of 517


Product Release Letter
2. The “Search Filters” expander is now expanded as default to highlight that a scope and database
selection is necessary. The Beneath element field is now always enabled (Checkbox removed) and
if you try to search with that field empty, it will do it on the world element (This has been
implemented by Peter Hall).

3. The “In Volume” checkbox under the “Within Volume” expander group is now only enabled if the
selected database type is “Design”.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 90 of 517


Product Release Letter

Description

ISODRAFT Pipe Piece Names (SI-76189)

The Pipe Piece Name parameters may be set via the Material List Options form :-

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 91 of 517


Product Release Letter

This invokes the following command to report the section of the Pipe Piece Name after the 3rd hyphen
delimiter in the Cut Pipe table :-

PPIECE ON AFTER 3 '-'

with the following example results :-

The Cut Pipe Report Format accessed from the Reports and Symbol File Options form now also
includes Pipe Piece Names.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 92 of 517


Product Release Letter

12.1.SP4.19

Description
Marine Drafting – Default Purge behaviour
Description

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 93 of 517


Product Release Letter
In Marine Drafting 12.1 SP4 it is now possible to configure how the ‘Purge” operation should treat
empty model subviews and views. The behaviour will be the same both during explicit Purge
(Tools/Inspect Drawing/Purge) & implicit Purge (automatically invoked in certain functions). The system
default configuration will result in same behavior as before (do not remove empty model subviews
during Purge & do not remove empty model views during implicit Purge ) with one exception: do not
remove empty model views during explicit Purge.

Note that the current way of handling empty model views in explicit Purge will be replaced by this
configuration tool.

For this purpose two new Drafting Default Keywords have been introduced.
Keyword:

MODEL_SUBVIEW_PURGE

System default value:

“None”

Explanation:

Controls how the ‘Purge” operation should treat empty model subviews

Legal values:

"None" Preserve empty model subviews

"SDB" Remove empty model subviews in drawing only (the models will come back
when the ID-list is re-evaluated).

"PADD" Remove empty model subviews in drawing and also remove the model from
the PADD View definition

Keyword:

MODEL_VIEW_PURGE

System default value:

“None”

Explanation:

Controls how the ‘Purge” operation should treat empty model views

Legal values:

"None" Preserve empty model views

"SDB" Remove empty model views in drawing only

"PADD" Remove empty model views in drawing and also remove the view definition in
PADD
Benefits

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 94 of 517


Product Release Letter
Possibility to control the behaviour in Purge functionality

Compatibility Constraints

None

For More Information

Please see the Marine Drafting documentation.

Affected Programs

Hull Design, Marine Drafting

12.1.SP4.17

Description

Cut Information for Elbows on Pipe Sketch

The cut information for elbows can now be added to the Pipe Sketch drawing.
The cut length is calculated according to the following equation:

ͦͦ
Inside Arc Length (Li) = 2πri x ( Ѳ / 360˚ ) ͦ ͦͦ ͦͦ
Centre Arc Length (Lc) = 2πrc x ( Ѳ / 360˚ ) ͦ ͦͦ ͦͦ
Centre Arc Length (Lo) = 2πro x ( Ѳ / 360˚ ) ͦ ͦͦ

The Cut Information Table is created in the drawing if a trim able elbow’s angle is not 90 deg or at least
different from its catalogue standard angle.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 95 of 517


Product Release Letter

In order to use this table, the user needs to create a NOTE in the outfitting draft module and set the
function of the NOTEs to ELBOCUTINFO as shown:

The method to create these notes is same is according to standards so please refer the Position and
Populate Backing Sheet in the user guide.

The MTO table contains the cutting angle information too.

Description

Integrator and Compare/Update links become No Claim

In PDMS and Marine 12.1.SP4.Fix17, the Integrator link references have been made no claim.

The reference attributes deslnk, schlnk and englnk are set on the CYMLNK object which is normally
hidden from the end user, and these appear as pseudo attributes on the individual 3D, schematic and
engineering objects.

This enhancement resolves the scenario such as where the engineering user links their object to the
schematic object and then the 3D designer links their object to the schematic object, only to find this
rejected because the CYMLNK was claimed by the other user. The second link action no longer require
a claim of the CYMLNK, and the 3D object will now be linked to both the schematic and engineering

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 96 of 517


Product Release Letter
objects. The first user will have the CYMLNK in their claim list since they created it, but this does not
prevent the second user from also linking.

Note that it is still necessary for the concurrent users to save and get work in order to see each other’s
changes.

When used in a global project, we recommend that the project administrator creates a variant extract of
the Ref-DESI database for the CYMWRL (Integrator link world) at each location. This will remove the
global extract claim for linking.

The impact with linking is that the last update wins. Following consultation with representative users this
was accepted as reasonable, given that real world scopes of work were unlikely to result in a conflict
from this change.

This enhancement will also be delivered in the future AVEVA Diagrams 14.1, AVEVA Engineering
14.1.SP1 and AVEVA Everything3D™ 2.1 releases.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 97 of 517


Product Release Letter
12.1.SP4.14

Description
FEM – ANSYS APDL Export

Description

A new option has been added that exports ANSYS APDL commands to create a mesh (nodes and
elements) instead of geometry from the Hull Finite Element Modeller output.

Benefits
More flexible ANSYS interface.
Compatibility Constraints
None.
Affected Programs
Hull Structural Design

Description
FEM – DNV Sesam Input Interface File Export

Description

A new export option has been added to export nodes and elements together with material and element
properties from FE models as Sesam Input Interface files which can be imported by DNV’s Sesam FEA
package.
The export function is available from Analysis | Export FE Model to Sesam FEM.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 98 of 517


Product Release Letter

Benefits
Direct interface to DNV’s FEA software

Compatibility Constraints
None

Affected Programs
Hull Structural Design

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 99 of 517


Product Release Letter
Description
FEM – Hull Finite Element Modeller Enhancements
Description
Significant improvements have been made to the Hull Finite Element Modeller especially regarding the
calculated geometry. The result is more mesh-like taking the intended element size into account.
Curved parts are much smoother following the geometry of the underlying surfaces.

The FE modelling process is now more adaptive and runs recursively until no further operations
(connecting, combining, dividing elements) are left to be done.

By setting the environment variable SBH_FEM_CALC_ALL_PROPS to YES more section derived


properties for beam elements will be calculated e.g. static area moment about y- and z-axis.
Benefits
Improved and more mesh-like FE model that can be exported in new data formats.

Compatibility Constraints
On customer request the number of section derived properties for beam elements in the FE model has
been increased. Therefore it is not possible to open new FE models with versions prior to 12.1.SP4.14.

Affected Programs
Hull Structural Design

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 100 of 517
Product Release Letter

Description
FEM – Nastran Bulk Data File Export

Description
A new export option has been added to export nodes and elements together with material and element
properties from FE models as Nastran Bulk Data files (BDF) which can be imported by a number of
FEA software packages.
The export function is available from Analysis | Export FE Model to Nastran BDF.

Benefits
Nastran BDF files can be imported by a number of FEA software packages.

Compatibility Constraints
None

Affected Programs
Hull Structural Design

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 101 of 517
Product Release Letter
Description
FEM – Patran PCL Export
Description
A new option has been added that exports Patran PCL commands to create a mesh (nodes and
elements) instead of geometry from the Hull Finite Element Modeller output.

Benefits
More flexible Patran interface.

Compatibility Constraints
None.

Affected Programs
Hull Structural Design

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 102 of 517
Product Release Letter
Description

Hull Design – Hull Mark Text

After store is chosen the functions moves from the multiple choice menu.

Benefits
Stable system behaviour.

Compatibility Constraints
None

For More Information


Only noted here.

Affected Programs
Hull Design

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 103 of 517
Product Release Letter
12.1.SP4.13

Description

REVERT Drawing Databases

In this hot fix there are some important changes to admin regarding the admin database operation
REVERT. The fix is improves how external files linked to database element are handled. Before this fix
it was difficult to use REVERT successfully in a PADD database where you store Marine Drafting
drawings. This documentation states what you need to consider if you want to use the new REVERT
functionality.

Storing of a Marine Drafting Drawing

Drawings created in Marine Drafting are special in that sense that they not only have data in the PADD
database they have additional information stored in the Marine Drawing object. This object normally
has a lot of data NOT stored in the PADD database. The Marine Drawing object is stored outside
PADD in an external file with .SDB extension. It is crucial that the SDB-files are properly maintained
otherwise the drawings will be corrupted.

Options for Saving Drawings - KEEP_SESSION_FILES

In case you want to use the database operations REVERT you must pay attention to the setting of the
Marine Drafting default keyword “KEEP_SESSION_FILES”. Every time you do “Save Drawing” in
Marine Drafting you will save a new version of the SDB-file. If you want to be able to REVERT you must
make sure you keep every version of the SDB-file by setting KEEP_SESSION_FILES to YES. You
must have used this consistently since you started to save drawings in the database. (For old database
where you don’t know how this setting has been used throughout the lifetime of the database, you
should MERGE CHANGES to get a fresh start).

Keeping all versions of the SDB files may bloat you disc storage. There are ways to clean up among
the SDB-files see below in section “Clean-Up of SDB-files”.

To be able to use the REVERT you must have run Marine Drafting with the drafting default setting
KEEP_SESSION_FILES = YES.

If you have done reverts with old version of Admin to your PADD databases the result is unpredictable
with respect to SDB-files. If you have database for which you don’t know the history with regarding
reverts, you should MERGE sessions to get a fresh start.

Clean-Up of SDB-files

You can clean up obsolete SDB-files in two ways:

1. When using the MERGE CHANGES command in Admin. Merge Changes means that some
session will be deleted and thus some versions of external files connected to the deleted
sessions will be obsolete. The merge command has an option to delete these obsolete external
files: FILEPURGE. See details the admin documentation: Administration\Reference
Manual\Command Details\Detailed Descriptions of Commands\ MERGE CHANGES (Project
Administration) >

2. By using a clean-up utility, “RemoveObsoleteSDB”. It can be activated in Marine Drafting or


Hull Design by the command “show !!RemoveObsoleteSDB”. Please see details in <reference:
Draft\Marine Drafting\Drafting\User Guide\Appendices\Remove Obsolete .SDB Files>

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 104 of 517
Product Release Letter

Description

Compare/Update Changes

Compare/Update now supports compare and import of Instruments from AVEVA Instrumentation to
Design element types Instrument, Equipment and Subequipment. This gives the capability, for
example, to separate instruments into inline, offline mounted, and offline non-mounted.

In order to use this new capability in existing projects it is necessary to replace one of the configuration
files. Delete the file DesignAIConfiguration.xml from the project folder <xxx>dflts\ModelManagement.
The system will subsequently copy the updated file in from the release folder. Any previously defined
configurations based on that combination of source and destination databases will need to be
configured again.

The integration UDA pmg-design-ai should have its element list extended to include types Cable,
Equipment, Instrument and Subequipment.

12.1.SP4.11

Description
Compare/Update and Integrator Changes
Merging of partially populated links

In Compare/Update and Schematic 3D Integrator, the Manage Links function to validate links will now
merge partially populated links, e.g. 3D object “A” is linked to schematic object “A” by one link and
schematic object “A” is linked to engineering object “A” by another link, as can occur when links are
created in separate extract databases.

A new PML method has been provided so that links can be validated from the command line. This can
be run using the following syntax:

import 'MMservices'
using namespace 'Aveva.Pdms.MMServices'
!!mmManageLinks = object mmManageLinks()
!!mmManageLinks.validate()

12.1.SP4.10:

Description
Dabacon Performance Enhancement
Title: Dabacon Performance enhancement, read multiple pages in one go.

Benefits: Database access will do fewer reads across the network reading more data at each time.

Activation: The performance improvement will activate automatically for Marine 12.1.SP4 applications
if the DbCacheService is installed and started.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 105 of 517
Product Release Letter

Description

Compare/Update Changes

Compare/Update has some small enhancements in response to project feedback.

• The user is no longer prompted automatically to enter a filter on selecting a data source (for the
case where a filter has not already been defined). The Filters button is now active as soon as a
data source is selected, so a filter can be defined if required, prior to selecting a configuration to
run for comparison.

• On the Update Database form, the defaults for the two check boxes labelled “Update attributes
for linked items” have been changed to be on, so attributes will be updated by default.

• In the Configuration Wizard, attribute mapping can now include PML expressions in place of
source attributes. On the Attribute Mapping screen the source side can now consist of:

o Select an attribute from the dropdown list.


o Type the name of a pseudo attribute.
o Type a PML expression, enclosed in brackets, e.g. (DESC of OWNE). The expression
will not be evaluated at this point but will be evaluated at comparison time against the
source object.
o Type a static value, to set a default value onto a target attribute. Any value entered in
this way will not be validated at this point.
• Hull element type pseudo attributes are now recognised in the Configuration Wizard Attribute
Mapping.

12.1.SP4.9:

Description
Marking Statement – Additions

Description
The marking statement used on planar panels has been extended to define and handle texts to be
labelled on plate parts in production. The contents of the label, the text height, the text rotation and the
side of the plate can be controlled by the user. The picture below shows the updated statement wizard
dialogue used for marking with the modifications related to the labelling encircled.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 106 of 517
Product Release Letter

The corresponding scheme syntax for marking is updated with new keywords, TXT and THGT, as
shown below.

Labels can be shown in symbolic views if requested. This is controlled by new entries in the dialogue
controlling the properties of the symbolic view (Symbolic View -> Planar Hull View -> Properties).

Benefits
Labelling of texts can be defined and maintained by the production engineer using Planar Hull
Modelling.

Compatibility Constraints
None

For More Information

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 107 of 517
Product Release Letter
See Manual Hull Detailed Design – Design Language of Hull Modelling and Hull Detailed Design –
User’s Guide

Affected Programs
AVEVA Marine Planar Hull

12.1.SP4.8:

Description

New Option added for Pipe Fabrication

A new option has been added to the SHEE element of a drawing template as described below.

The value of FUNC can have two options.


FUNC ‘SAME-SCALE;FOUR_VIEWS_OFF’

NOTE.) The ordering is important to use the option.

The option is separated by “;” (semi-colon)

1. SAME-SCALE :
This option is used to make same scale views.

2. FOUR_VIEWS_ON:
Show always four views. All four views are displayed even if the spool is located in one plane.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 108 of 517
Product Release Letter

FOUR_VEWS_OFF (Default):
Show only one view if the spool is located in one plane.
All views will be merged to just one view.

If the value of function has no definition about “FOUR_VIEW_OFF”, the “FOUR_VIEW_OFF” will
be applied as default.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 109 of 517
Product Release Letter

The view size and location is calculated using existing views.

But, if the spool is not located in one place, this option is set to “FOUR_VIEWS_ON” automatically.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 110 of 517
Product Release Letter

12.1.SP4.6:

Description
Planar Hull - Marking Functionality Enhancement
For a complete description please refer to the attachment provided in the Knowledge Base Item 4997 in
AVEVA Helpdesk.

12.1.SP4.4:

Description
Marine Drafting – WCOG for Outfitting Models

Description
The dimension function “Weight and COG” in Marine Drafting can be used to calculate WCOG for all or
some models in the view. You select models by selecting subviews in the drawing. A problem is that
the subview levels for outfitting models are not always a level that is relevant for WCOG calculation. For
example: for equipment, the subview can correspond to a TEMPL and not the equipment itself. For
pipes it is the BRAN that is the subview level.

To make this easier there is now a new drafting default keyword:

AUTO_OUTFITTING_LEVEL

It can have the following values:

NO Default. No change in behaviour, as before.


When selecting outfitting subviews the system will
YES always select a “pre-defined” model level no matter
what the subview represents. The pre-define levels

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 111 of 517
Product Release Letter
are: EQUI, STRU, PIPE, ROOM, VENT and
CWAY. So for the examples given above: WCOG
will be calculated for the equipment and the pipe
although the actual subviews represent something
else (TEMPL and BRAN).
The new keyword also has a similar effect on the function “Tools/Model/Copy”: For outfitting models
you will copy an EQUI, STRU, PIPE, ROOM, VENT or CWAY disregarding what the subview level
represents.

Benefits
It is now easier to create WCOG dimensions for outfitting models and to copy outfitting models between
views.

Compatibility Constraints
None

For More Information


Only noted here.

Affected Programs
Marine Drafting/Hull Design

Description
Piping components and their insulation drawn in the same graphical view

Over the years there have been many requests to provide functionality that allows for both piping
components and their insulation to be drawn in the same graphical view. This has not previously been
possible because insulation is not a separate entity and insulation parameters merely change the
physical size of the component.
In resolving this, we have changed the way in which the attribute ‘Insulation’ of the Representation
Style is used for the Piping Insulation.

• The Insulation flag does not now solely toggle Pipe Insulation On and Off

• The insulation flag continues to work as it did for all other insulation types

• There are two new Representation Style attributes that are used solely for Pipe Insulation.

PINSSTYLE integer/line_pattern the default value is OFF


PINSCOLOUR integer/colour_name

The result of using these new Representation Style attributes is as follows;

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 112 of 517
Product Release Letter

Fig1 Fig2 Fig3

Fig1. The Tube Flag is ON, the FFSTYLE is set to Solid, the Insulation flag is OFF and PINSSTYLE
is OFF. The result would be the same if the PINSSTYLE was set because the Insulation flag
still controls the toggling of all insulation.

Fig2. The Tube Flag is ON, the FFSTYLE is set to Solid, the Insulation flag is ON, the PINSSTYLE is
set to Dashed and the PINSCOLOUR is set to Blue

Fig3. The Tube Flag is ON, the FFSTYLE is set to Dashed, Insulation flag is ON, the PINSSTYLE is
set to Solid and the PINSCOLOUR is set to Blue.

Notice that the tube is dashed for only those that have insulation. To produce this type of
display, you will need to use two rules, one for the dashed tube and another for the solid tube.
The rule for the dashed tube shown here would contain a criterion such as the following;

USE STYLE /dashed_style FOR ALL BRAN MEM WITH INTHICK NEQ 0

Otherwise, the result would be that all tube were displayed dashed.

Please Note: Drawing both Pipe and Pipe Insulation in the same view means more graphics processing
and it will take longer to produce such a view compared to one that contains just Pipe or just Pipe
Insulation.

Please Note: For examples of DRAFT styles and rules that take advantage of the new features, please
see release 52212.

12.1.SP4.1:

Description
Marine Drafting – Capturing Subpictures in Regroup and Split Functions

Description

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 113 of 517
Product Release Letter
In Marine Drafting 12.1 SP4 Hotfix 1, an alternative to explicitly picking subpictures during Regroup and
Split operations has been implemented.

• When regrouping subpictures (views/subviews/components) by picking subordinates/neighbours,


all subpictures totally inside a user defined rectangle/polygon can now be captured by clicking the
Options button when the user is asked to indicate a subordinate/neighbour.

• When splitting subpictures (views or subviews) by picking subordinates, all subpictures totally
inside a user defined rectangle/polygon can now be captured by clicking the Options button when
the user is asked to indicate a subordinate.

Benefits
Improved UI for subpicture selection during Regroup and Split operation.

Compatibility Constraints
None

For More Information


Please see the Marine Drafting documentation.

Affected Programs
Hull Design

Marine Drafting

Description
Marine Drafting – Drafting Default Keyword for Modal Text Height

Description
In Marine Drafting 12.1 SP4 Hotfix 1, a new Drafting Default keyword has been introduced, controlling
the modal text height for ordinary texts.

Keyword:

TEXT_HEIGHT

System default value:

Same value as TEXT_STD_HEIGHT (when loading a default file, if the keyword


TEXT_HEIGHT is missing then the value of the TEXT_STD_HEIGHT is used)

Explanation:

The modal height for ordinary texts

Legal values:

Positive

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 114 of 517
Product Release Letter
NOTE: TEXT_HEIGHT should not be confused with TEXT_STD_HEIGHT! The latter is used
as a selectable choice in certain situations when changing the modal text height in interaction
with the user.

Benefits
Possibility to control the modal text height via the Drafting Default file

Compatibility Constraints
None

For More Information


Please see the Marine Drafting documentation.

Affected Programs
Hull Design

Marine Drafting

Description
Marine Drafting – Lock to Cardinal Axis by <Shift>

Description
In Marine Drafting 12.1 SP4 Hotfix 1, a more efficient alternative to the LockU and LockV commands
has been implemented. By pressing the <Shift> key while giving a position in the drawing canvas, the
resulting line/chord will be locked along the closest cardinal (horizontal or vertical) axis.
The "lock to cardinal axis by pressing <Shift> key" has been implemented in all situations
where defining
- a line segment
- an arc segment by three points
- an arc segment by end points and amplitude/radius

Below functions are affected:


- Insert/Line 2 points
- Insert/Arc 3 points
- Insert/Arc 2 points and amplitude/radius
- Insert/Polyline (all line and arc definitions)
- Annotate/General Note (during leader line definition)
- Annotate/Position Number (during leader line definition)
- Annotate/Hull Note (during leader line definition)

Also see documentation of Drafting default keyword LINE_HV_CODE for automatic locking to cardinal
axes (without using LockU/LockV functions or pressing <Shift> key).

Benefits

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 115 of 517
Product Release Letter
Efficient UI for locking to cardinal axis

Compatibility Constraints
None

For More Information


Only noted here

Affected Programs
Hull Design, Marine Drafting

Description

Compare Update

In Compare/Update the setting to Use advanced configuration has been moved from the Options
dialogue to a new screen in the Configurations Wizard. This means that end users no longer see this
option and it is controlled by the administrator to ensure consistent use on the project.

If advanced rules are required for this particular configuration, select a Project Configuration File (this
will usually be the default filename for the project, e.g. for Sample project this would be
%SAMDFLTS%\ModelManagement\ProjectConfiguration.xml). Then select a Rule Set and check Use
Advanced Rules.

Check Restrict the Configuration to Admin Users only if you want to test this configuration before
publishing it for general use on the project.

Description

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 116 of 517
Product Release Letter
Multi-Discipline Supports Enhancements
A number of product enhancements have been introduced in MDS at this release. As a result of this,
user application data stored in the MDS/APPDEFAULTS database needs to be updated to take
advantage of these enhancements.

This can be achieved simply by an administrator in the Paragon module by using the “Check MDS
Application Defaults” utility provided in the Utilities menu.

See section entitled: Update Existing Client Project Application Defaults Databases in the Multi-
Discipline Supports Administrator Guide.

MDS has been enhanced to allow the Unique Naming of Supports, the Designer is prompted to Name
each Support Ancillary. This can be turned off In Paragon by unselecting Unique Support Names on the
Options (2) Tab of the Modify > Application Defaults Form.

Documentation for these enhancements is provided within the following product manuals;

Design Common Functionality User Guide (Support Clashing)

Multi-Discipline Supports User Guide and Multi-Discipline Supports Administrator Guide

(Preliminary Support Conversion, Support Functions, Reference Supports, Compensating Plates,


Add/Remove Toolbar, ABA Location Plan Grid Defaults, Hanger Interface Selection,
User Defined Ancillary Selection Criteria and Hanger Support Creation Zones)

Multi-Discipline Supports – Reference Databases

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 117 of 517
Product Release Letter
At release 12.1.SP4 the method in which MDS reference databases (i.e. MDS/CATA) are delivered has
been altered such that the MDS project is no longer supplied with the product.

MDS reference databases are now contained within the MAS project that forms part of the standard
product installation. This change was necessary to ensure on-going compatibility with the core product.

MDS users will need to reset the pointers to the MDS reference databases within their projects and re-
establish these databases within individual MDB’s

User definable content databases such as MDS/APPDEFAULTS and template databases do not need
to be re-associated.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 118 of 517
Product Release Letter
List of Fault Corrections
This release addresses the following defect reports:

In this release:

Planar Hull:

Incident Issue Description


Number Number
22560, 68699, Title: Ehancement to draw the excess for the bracket and stiffener into the
89560, 191867, symbolic view
133752, 306238, Symptoms: See title.
131870, 299379, Previous/Known workaround: N/A
113905 249046 Solution: The keyword DRAW_EXC_BRA_STI is now implemented. When set
excess for stiffeners and brackets will be written. When the value is 'NOT SET'
this will behave as before.
122914 277442 Title: Problem for the knee of X-bevel with the variant 9 not to be centred in the
middle of the plate
Symptoms: If the X-bevel (bevel type 50) are defined with a difference in plate
thicknesses and centre plane of plates. This should then result in variant 9.

The knee of X-bevel with the variant 9 is not centred in the middle of the plate.
Instead it is assymetrical.
Previous/Known workaround: No known workaround exists.
Solution: This is now adjusted so the X-bevel is correctly centered.
124494 280796 Title: An System error WA201(0)=1005 occur when open or running the scheme
in knuckled panel.
Symptoms: The error is there if a sub-panel contains a welded flange.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the scheme of the knuckled
panel is running without error.
141818 336001 Title: When Copy the panel, SUS=0; is added to target panel after copy the
panel.
Symptoms: See title
Previous/Known workaround: Remove SUS=0 using schema editor.
Solution: Corrected so the SUS=0 keyword will not appear.
145284 347703 Title: In the syntax 8 bracket, if the bracket name starts with the letter G, the
bracket toe is not generated.
Symptoms: See title
Previous/Known workaround: Rename the bracket so the first letter is not a
"G".
Solution: Corrected so the letter G will not influence the bracket toe.
149406 360962 Title: GEN_VIEW=Single does not work in Hull Design
Symptoms: Using GEN_VIEW=SINGLE has no effect. All views are updated
anyway.
Previous/Known workaround: This is a problem introduced in 12.1.SP4 Fix.51
and there are no known workarounds for this.
Solution: Corrected so GEN_VIEW=SINGLE will work as expected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 119 of 517
Product Release Letter
Incident Issue Description
Number Number
362130 Title: An error occurs when defining a boundary using Profile Crosssection
Symptoms: Using the option "Profile Crossection" in the Statement Wizard will
fail and give the system response: Error Message: Can not interpret scheme
string with profile references!)
Previous/Known workaround: Manually change in the schema.
Solution: Corrected so the crossection boundary will be used.
149902 363240 Title: Stiffener End Symbol is different between AM12.1 SP4.37 and SP5.
Symptoms: Wrong endcut symbols for sniped endcuts in symbolic views.
Previous/Known workaround:
A change in the code has made the system to draw the wrong endcut symbol. To
get arround the problem the default keyword NOENDCUTSYMB has to be unset
from the beginning of the session (Is probably like this at the customer).
Further the environment variable SBH_PROF_END_SYMBOL_TAB has to be set
to any value.
This is a temporary workarround. We will adjust the code to work correctly again.
Solution: The error has been corrected so the correct endcut symbol is set.
142815 366154 Title: MAT_SYMB_SYMBNO_OFF does not work properly when stiffener is
referenced to the flanges of the panel.
Symptoms: When stiffener is created between two T-bar profile types, then the
stiffener material is displayed correctly. However, if the same stiffener is created
between two panels + flanges, that represents T-bar profiles, result is different. In
that case, material symbol is not correctly displayed.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the flange reference will also be recognised when the
material symbol is set.
150582 366163 Title: An error occurs when defining a boundary using Profile Crosssection
Symptoms: Using the option "Profile Crossection" in the Statement Wizard will
fail and give the system responce: Error Message: Can not interpret scheme
string with profile references!)
Previous/Known workaround: Manually change in the schema.
Solution: Corrected so the crossection boundary will be used.
150852 366796 Title: Chamfer symbol is not correct only on section view from aft.
Symptoms: In some cases, the chamfer symbol is not displayed correctly in the
symbolic view.
Previous/Known workaround: No known workaound exists.
Solution: Corrected so the chamfer symbol is correctly displayed in all views.
151193 367818 Title: In symbolic view draw line for chamfer defined on the other side of the
panel
Symptoms: Until know a short-dashed normal line has been drawn along the
plate edge for bevel with chamfer defined for the side of the plate the user is
looking at. If the chamfer is on the far side no line is drawn.
Previous/Known workaround: No known workaound exists.
Solution: A new default value CHAMFER_OTHER_SIDE has been added. If set,
a dashed and double dotted normal line is drawn along the plate edge if a
chamfer is defined for the bevel on the other side.

Hull Production:

Incident Issue Description


Number Number
73391, 156975, Title: Corrections for Hullmarks
93954, 200709, Symptoms: When Hullmarks, produced as plates/welds, are checked, the shape is
138957 325207 not correct.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the resulting shape will be ok.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 120 of 517
Product Release Letter
Incident Issue Description
Number Number
86101 183801 Title: Error of ppapanparts - excess in the inner seam(REX=1)
Symptoms: Adding excess to an inner seam as in the below example (red text) will
fail when trying to create he part via ppanparts.

Previous/Known workaround: Skip the excess in such case.


Solution: The problem relates to that the seam with excess is intersecting an "inner
corner" of the outer contour. The process to apply excess on inner seams can handle
this situation since the intersection between the seam and the outer contour is not
really useful when creating the plate.
The effect of the error is that no part is created and a crash can happen.
We can not add excess to this limit using the current method.
Instead the error is a plate is created without the excess.
The log file will get the following printout:
"Plate excess on <plate name> is not handled. Reverted back to zero."
105483 226552 Title: Hull Curve does not reflected to Jig of SB Cpanel.
Symptoms: Starboard hull curve is not added to the Jig drawing.
Previous/Known workaround: No known workaround exists.
Solution: Starboard hull curves are now also included in the Jig drawing.
105632 226841 Title: The shape of HullCurve is strange with Jig Pillars.
Symptoms: A knuckled curve is not presented correctly in the Jig pillar receipt
drawing.
Previous/Known workaround: No known workaround exists.
Solution: A method has been added to detect knuckles in curves and see to that the
curve is divided in that point to get good result.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 121 of 517
Product Release Letter
Incident Issue Description
Number Number
128994 295919 Title: Ppanparts error occur if excess is applied to only one limit on two consecutive
panel limits.
Symptoms: The plate is not created in this case:

Previous/Known workaround: If excess can be omitted, then exclude the excess


and the part will be created.
Solution: Adjusted to create a correct plate.
138474 323390 Title: OSP behaviour is different on same bend panel having different orientation
Symptoms: For a small bent panel there is no production result via Hull PPI.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the small bent panels will produce production material via Hull
PPI.
139526 327233 Title: Problem for the weight of the manufacture part to be wrong
Symptoms: The weight of the plate part to be converted into built-up is wrong.
Their weight is calculated from PLAREA, However the weight have to be calculated
from OUAREA
Previous/Known workaround: No known workaround exists.
Solution: When creating parts of shell profiles the calculation of the weight considers
the endcut geometry. This calculation has now been corrected.
142087 336750 Title: Problem for the side of the bevel of the shell profiles to be wrong according to
MARK_ABUTTING_PP
Symptoms: If MARK_ABUTTING_PP is not given into the cpanparts.ip, the side of
the bevel for some shell stiffeners is wrong and the endcut direction,the snip direction,
of the flange of the builtup profiles is wrong.
Previous/Known workaround: No known workaround exists.
Solution: Bevel side definition for plate parts from built shell profiles has been
corrected.
144753 345974 Title: The manwgh of MPROF is strange with Shrinkage.
Symptoms: If shrinkage is defined , the ManWgh of MPROF does not change but
Totlen is extending in production.
Previous/Known workaround: No kown workaround exists
Solution: Profile weight calculation corrected to take account of shrinkage.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 122 of 517
Product Release Letter
Incident Issue Description
Number Number
145798 349189 Title: If set the SBH_WIDE_CHAMFER, Bevel Type30 has strange value with variant
in Gen.file.
Symptoms: If wide chamfer is used with bevel type 30, variant 1, the chamfer width
this side is not correct.
Previous/Known workaround: No known workaround exists.
Solution: Corrected calculation of chamfer width and height for bevel type 30 variant
1.
147230 353897 Title: The hole position on PLDB is strange, When using Prof to PLDB.
Symptoms: See title
Previous/Known workaround: No known workaround exists.
Solution: The position for standard hole, notch and cutout markings on web plate
parts created from double curved shell stiffeners has been corrected.
147236 353924 Title: The hcofg/mancog of clips are strange with Cstiffener.
Symptoms: The CoG for a clip defined in a cutout for a shell stiffener is not correct.
Previous/Known workaround: No known workaround exists.
Solution: Corrected calculation of centre of gravity for clip parts.
148593 358251 Title: Enhancement request V/CMARK direction with swage.
Symptoms: When swage is used then marking on abutting plates are not following
the mould line. It is sometimes moved the plate thickness.
Previous/Known workaround: Set GMS in the planar panel PAN statement to force
the system to use a specific markingside.
Solution:
When markingside is decided in this priority order.
1. If GMS is given in the panel statement of the planar panel, then this will be priority.
2. If any swage is found in the panel, then markingside will be set to the opposite of
the first found swage.

If no markingside is set, then continue with:


3. Check if SBH_MARKING_SIDE is defined in the d065 file
4. Check if SBH_GSD_MARKING_SIDE is defined in the d065 file

If (3) or (4) then the system counts number of stiffeners and brackets on each side of
the panel.

If still no markingside has been set:


5. Mould side of the first plate in the panel
6. If mould side does not coincide with plate edge, then for all stiffeners on panel (with
same lowest assembly structure)

Finally, if still no markingside is set, the markingside will be on the positive w side of
the plate.

A new keyword has been added to ppanpanparts.ip.

IGNORE_SWAGE_MARKINGSIDE

If this is given in ppanparts.ip, then swage will not be taken in consideration when the
system determits the marking side of the plate parts. I.e. step no 2 above will be
ignored.
149939 363620 Title: The weight and area(PlArea) are not correct for the knuckled panel which
created by 3 points.
Symptoms: In case of shrinkage is added to a knuckled panel, the shrinkage factor is
not handled for the weight calculation of the plate parts.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that shrinkage is considered when calculating weight of parts
created from a knuckled panel.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 123 of 517
Product Release Letter
Incident Issue Description
Number Number
150223 365015 Title: A lack and unnecessary the attach_angle on Mplate in sp4.55
Symptoms: Some attachment angles are missing or incorrect on the shell plate.
Previous/Known workaround: No known workaround exists.
Solution: Adjustments to Attach angles for both planar panels and shell profiles
attached to the shell plate.
151772 369348 Title: The result of Ppanparts is strange, if plate has 450mm or less in width.
Symptoms: If a plate width is 450 mm or smaller, ppanparts failes to create the
MANU plate part.
This is from version 12.1.SP4 Fix.53.
Previous/Known workaround: No known workaround exists.
Solution: Fixed so the plate will be properly created.
151689 369612 Title: Curved part generation has a problem
Symptoms: Adding more than 100 MARK_CURVE statements for SPanParts will
have no effect. Only the first 100 are used.
Previous/Known workaround: The limit of 100 MARK_CURVE is noted in
documentation.
Solution: The limit of 100 MARK_CURVE has been increased to 500.
152913 373238 Title: Marking name of stiffener and that of attaching angle in gen. file is different
when panel
Symptoms: The MARKING_NAME in the generic file does not match for
stiffenermarking, GSD and Inclination angle markings for Knuckle panel plates.
Previous/Known workaround: No known workaround exists.
Solution: Correctedd so the marking names for stiffeners, GSD's and Inclination
angle marking gets the same name reference also for knuckled panels.

Marine Drafting:

Incident Issue Description


Number Number
125918 282959 Title: Multiple Hull Posno notes - wrong after view-recreate
Symptoms: Multiple Hull Posno notes have been defined for profiles on view.
Then - Posno note was moved by "Modify - Move - Reference". Everything OK so
far. But when you use "View Recreate" and do the same (move reference) - the
resulting posno note is damaged.
Previous/Known workaround: No known workaround exists.
Solution: Handling of Multiple Hull Posno references are corrected.
139547 327238 Title: MarDex.getreavec2d function is not working with PML.
Symptoms: See title.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the method can be used. Also method getreavec3d is
corrected.

Outfitting:

Incident Issue Description


Number Number
88115 188500 Title: Customisation and Common framework - 12.1.SP4-Outfitting Model Editor
right click for Enter Value the input text box not current active
131936 299474 Title: Isodraft - End Preparations incorrect for Pipe to Pipe connections
Symptoms: Incorrect End Preparations in Cut Pipe list
Previous/Known workaround: None
Solution: Write End Preparation records to Trasfer File for Pipe to Pipe
connections.
145678 348875 Title: Draft - Zone and Layer name requirement for DWG output

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 124 of 517
Product Release Letter
Incident Issue Description
Number Number
147539 355175 Title: Design - Unwanted messages in console and multiple calls to DB server in
Model Editor
Symptoms: Message PDMS_Element :: getIsMovable (1) in console
Previous/Known workaround: n/a
Solution: The message is removed. Regarding the DB access, its purpose is to
check if any parts of the current selection are claimed by another user. It cannot
be removed. A workaround to reduce the DB impact is to avoid selecting too
many elements for Model Editor manipulation.
146119 359783 Title: Isodraft - Incorrect tube MTO when tee offleg connected to branch tail
Symptoms: Tube MTO does not match material list in PDMS-VPRM Gateway MTO file
Previous/Known workaround: None
Solution: Isodraft fix to correct -39 reference record for Tee offleg connected to
branch tail.

Consolidated from previous fix releases:

12.1.SP4.55

Planar Hull:

Incident Issue Description


Number Number
110019 238590 Title: If using minus bevel code, the Bevel direction is reversed.
Symptoms: When the panel is stored, the bevel direction 'BVS =' is written by
system.
In case the bevel code has been given as a number with minus sign, this minus
sign will always remain and bevel side is at the end wrong.
Previous/Known workaround: Manually remove the minus sign in the schema
editor.
Solution: When bevel side, BVS, is given, the bevel code is always presented as
the absolut value as it should since BVS is given.
138909 325114 Title: Additional attributes in HPANBI
Symptoms: N/A
Previous/Known workaround: N/A
Solution: New attributes added to HPANBI (Hull Panel Boundary Interval)
New added attributes are:
Weldos - Welding depth other side
Welmtd - Weld method used for the interval
Sussta - Suspension at the start of interval
Susend - Suspension at the end of interval
144108 344204 Title: After input BCF in Clip Weld, BCF value disappear.
Symptoms: When defining bevel for BCF (on clip), the value is missing after
panel is saved.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so BCF will be kept.
145207 347443 Title: Probolem for chamfer not to be applied to the limit along the curve
Symptoms: When a planar panel limit is created by an internal curve (CUR
stmt), there is no recognition for chamfer in the resulting part.
Previous/Known workaround: No known workaround exists.
Solution: Limits generated by curves will now also be considered when chamfer
is calculated in planar panel parts generation.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 125 of 517
Product Release Letter
Incident Issue Description
Number Number
145293 347704 Title: Enhancement request for penetration symbol of the profile.
Symptoms: Need a possibillity to only get exact match for the penetrating
symbols.
Previous/Known workaround: N/A
Solution: We have added a new default value HOLNOT_MATCH_EXACT that
makes it possible to control what symbols should be put on the drawing. When it's
set, the type and size of the holes and notches must match exactly to what is in
the control file. Otherwise the funtionality is as before.

Curved Hull:

Incident Issue Description


Number Number
91913 197487 Title: AM12.1.SP4.30 - Shellx not correctly recreated

Hull Production:

Incident Issue Description


Number Number
124685 279865 Title: The attachment angles of SB panel displayed on plate parts is strange.
Symptoms: The attachment angles of planar panels on shell plates are not always
correct on SB shell plates.
Previous/Known workaround: No known workaround exits.
Solution: Corrected so the attachment angles on SB plate will be correct.
132221 300380 Title: A lack of attachment angle markings or wrong angle values.
Symptoms: Some planar panel attachment angle marking is missing. Also there is
no marking name in the generic file for the planar panels and shell stiffeners.
Previous/Known workaround: No known workaround exists.
Solution: Missing attachment marking is included.
Also marking name for abutting planar panel and marking name for shell stiffeners
added in the generic file.
133705 306629 Title: GSD does not apply to built-up profile of shell
Symptoms: See title
Previous/Known workaround: No known workaround exists as this has not been
implemented.
Solution: GSD markings for built shell stiffeners implemented.
142499 338942 Title: Problem for variable bevelling of the certain shell stifeners to be wrong
Symptoms: A shell stiffener that is converted into a plate part gets wrong varying
bevel along the trace in the MPLATE part.
Previous/Known workaround: No known workaround exists.
Solution: Bevel and angle info along trace corrected.
145929 349515 Title: The KU-Notch position is 2mm off with curve on profile sketch.
Symptoms: In the profile sketch, the KU notch in a profile is not placed at the
correct distance.
Previous/Known workaround: No known workaround exists.
Solution: Distance for hole, notch and cutout-markings on bent profiles has been
corrected.
145884 351030 Title: The direction of profile in gen file is not correct for STBD panel.
Symptoms: After running Plane Part Generation and Profile and Sketch, it can be
seen that Profile sketches are displaying wrong side at the end of profile (shell
instead of CL). Error occurs only in profiles created on Starboard panels.
Previous/Known workaround: No known workaround exists.
Solution: Profile direction info has been corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 126 of 517
Product Release Letter
Incident Issue Description
Number Number
148875 359140 Title: The attached angles of longi are strange on SB mplate.
Symptoms: Some Shell Stiffener attachment angle marking are strange on SB side
of MPLATEs.
Previous/Known workaround: No known workaround exists.
Solution: The attachment angle markings are corrected.

Hull Nesting:

Incident Issue Description


Number Number
134451 308358 Title: User want not to create bridge automatically on limit with bevel partially.
Symptoms: When a bevelintervall ends along a part limit a bridge and auxiliary
function is automatically created by the system. THre is no way to prevent the
system to create this.
Previous/Known workaround: No workaround exists.
Solution: A new deafult keyword is added to the Nesting system.
BRIDGE_BEVEL_GAP - indicates if a bridge is to be created along a limit when
there is a bevel change.
The keyword can have any of the two values
No = No gap is wanted
Yes = Gap is wanted (default)
The bridge with for this gap can be controlled via the keyword
BRIDGE_WIDTH_BEVEL_GAP.

Marine Drafting:

Incident Issue Description


Number Number
65587 123301 Title: Brackets not displayed in Hull Symbolic View
Symptoms: When making a symbolic view and only a bracket on a planar panel
is within the drawing depth, this is not included in the symbolic view.
Known workaround: No known workaround exists.
Solution: Searching is updated to also include planar panels where only the
brackets are inside the drawing depth.

Outfitting:

Incident Issue Description


Number Number
71980 146256 Title: Isodraft - Dimension lines overlap in some cases.
Symptoms: The combination of 'Dimensions Composite ON' and 'Dimensions
Hangers OPPOSITE strings' in option file cause some dimension lines overlap.
Known workaround: None
Solution: If support dimension on opposite side, still retain support dimension
standout distance.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 127 of 517
Product Release Letter
Incident Issue Description
Number Number
74647 152974 Title: Structures - The 'Align secondary nodes' functionality does not produce
correct results
Symptoms: When connected SCTNs are moved and 'Align secondary nodes'
functionality is applied to the secondary nodes on the owning SCTNs, their nodes
got updated to the wrong positions of their owning SCTNs.
Known workaround: Manually correct the ZDistance of the secondary node of
the SCTN
Solution: The cause of this issue is from a functionality within the section
connection manager to calculate new ZDistance of the secondary node, which
uses the wrong type of P-line. The resolution for this involves the right type of P-
line being used.
91173 195694 Title: Isodraft - #Iso Generation Error #PDMS12.0.SP6 #Fix54,55,56 #Slope Tee
Symptoms: If a tee is part of a 3-d skew, sometimes causes a kink in the skewed
tee.
Previous/Known workaround: None
Solution: If a tee is part of a 3-d skew, do not add on the truncation offset - it can
cause a kink in the skewed tee.
317058 Title: Isodraft - SUPVFA pseudo attribute not working correctly in some
configurations
Symptoms: Orientation flag false when it should be true.
Previous/Known workaround: No known workaround.
Solution: The orientation flag is evaluated correctly now.
109384 319838 Title: Isodraft - Spec name changes not highlighted when text repositioned
Symptoms: Spec name changes not highlighted.
Previous/Known workaround: None
Solution: Highlight any spec names changes.
140944 337479 Title: Isodraft - Cut pipe spool number and bore size does not match
Symptoms: Cut pipe spool number and bore size does not match
Previous/Known workaround: None
Solution: Handle the case of a portion of tube which has been nominated as to
be 'dotted and dimensioned' and 'not to be included on the Material List'. This
portion of tube, however does not form a separate cut length, but is still part of
the header tube.
145486 348647 Title: Piping - Error message would appear when Placing piping component
using 3D pick
Symptoms: Error message would appear when Placing piping component using
3D pick.
Previous/Known workaround: None
Solution: The error has now been resolved.
147022 353146 Title: Cable - In Paragon, SREV elements are displayed in the wrong place.
Symptoms: With the graphics set to use translucent obstruction, SREV element
are drawn in the wrong place although they appear correctly with the solid
obstruction setting.
Previous/Known workaround: None.
Solution: A transform used to position the graphics was being applied twice
instead of once. This has been corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 128 of 517
Product Release Letter
12.1.SP4.54

PML Hull:

Incident Issue Description


Number Number
140312 330675 Title: Problem about the limitation to set the number of the longitudinal or curves
in Shell Expansion
Symptoms: Whgen using the API MarShellXViewOptions it is only possible to
add ten individual seams, longitudinals and transversals.
Previous/Known workaround: No known workaround exists.
Solution: The function has been enhanced so that it's possible to add up to 20
items individually for seams, longitudinals and transversals.

Planar Hull:

Incident Issue Description


Number Number
103574 222280 Title: Swedge symbol not visible in SB Panel of SBP Panel
Symptoms: On a symmetrical planar panel containing swage, the symbols on SB
side is not visible.
Previous/Known workaround: No known workaround exists.
Solution: Corrected. The symbols on the SB image is also presented in the
symbolic view.
131889 299505 Title: Design panel renaming
Symptoms: When Design panel is renamed in Global project and you have not
write permissions to production block, the reference to production panel will be lost.
Previous/Known workaround: Make sure there are write access to the production
blocks.
Solution: Renaming of panels in a multiview project now works under the same
conditions as other changes. Note however the special case when a panel is
renamed multiple times then the modification needs to be picked up on the other
side (design/production) after every change.
136600 317755 Title: Multiview: Taps disappear after accepting updates from design
Symptoms: Tap pieces disappear from the Production panel when the updates
from the Design are accepted without any warning.
Previous/Known workaround: None
Solution: Tap pieces are now persistent in the Production panel.
137999 321481 Title: Probolem for chamfer not to be applied to the limit along the curve
Symptoms: The limit to be generated by curve does not create the chamfer
although the thickness difference exceeds CHAMFER_STEP
Previous/Known workaround: Try and make another type of boundary that is not
an internal curve.
Solution: When a boundary limit was made by an internal curve, this limit was
excluded from the check for chamfer. This type of limit is now included in the check.
139948 328424 Title: After create a knuckled panel, view is not updated immediatly.
Symptoms: Picture not updated correctly
Previous/Known workaround: Manual changes
Solution: Subpanels now removed from picture when creating knuckled panel.
140204 330910 Title: Problem not to properlty check for bevel overlap in WELD stmt
Symptoms: The tolerance for the overlap check of bevel intervals along a planar
panel limit is too large.
Previous/Known workaround: No known workaround exists.
Solution: The overlap check has been refined. The tolerance for an overlap is less
than 0.1 mm.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 129 of 517
Product Release Letter
Incident Issue Description
Number Number
141163 334161 Title: Incorrect hull texts
Symptoms: Hull texts incorrectly translated if local origin not the same as the
global. This imay be the case on 3 point panels
Previous/Known workaround: Adjust origin
Solution: This is now corrected.

Curved Hull:

Incident Issue Description


Number Number
94105 201029 Title: Combining Curved Panels with holes.
Symptoms: Holes from the second panel was not handled.
Previous/Known workaround: Remake the holes again.
Solution: The function now handles all holes.
123410 276457 Title: Hull Tools Dimensioning
Symptoms: All not relevant intersection points collected.
Previous/Known workaround: Manual dimensioning.
Solution: All intersections are now calculated.
300195 Title: Fixed number of decimals in XML output.
Symptoms: The number of decimals is always 2.
Previous/Known workaround: No workaround.
Solution: The default value NO_OF_COORD_DEC is
also taken into consideration for the number of decimals. This means that
the decimals will be at least 2.
143344 341361 Title: Combining Curved Panels with holes.
Symptoms: Holes from the second panel was not handled.
Previous/Known workaround: Remake the holes again.
Solution: The function now handles all holes.

Hull Production:

Incident Issue Description


Number Number
138474 323390 Title: OSP behaviour is different on same bend panel having different orientation
Symptoms: For a small bent panel there is no production result via Hull PPI.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the small bent panels will produce production material via
Hull PPI.
139301 326328 Title: Pillar marking on plates
Symptoms: Marking for pillars missing
Previous/Known workaround: None
Solution: This has now been resolved.
139620 327790 Title: SB section transferred as PS panel
Symptoms: An outfitting structure is defined on SB side. When trasnferring it to
production, it is shown on PS.
Previous/Known workaround: No known workaround exists.
Solution: Transferred outfitting panels get a proper valid side code.
140215 329567 Title: Flanges in hole - splitting crash
Symptoms: A crash in PpanParts
Previous/Known workaround: None
Solution: Geometry handling is adjusted and correct result is now delivered.
138716 331080 Title: Automatic calculation of variant is not correct for butt welds.
Symptoms: Incorrect variant
Previous/Known workaround: Manual full definition
Solution: Automatic calculation of variant gives correct result.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 130 of 517
Product Release Letter
Incident Issue Description
Number Number
142726 338943, Title: Hull PPI API
337937 Symptoms: Two known problams.
1. When using te PPI for "partslist", the API will end with an error.

2. When using the API for "wcog", no result is produced.

Previous/Known workaround: No known workaround exists.


Solution: Both issues are resolved.
"partslist" do not end with the error.
"wcog" wil produce a result.
143202, 340485, Title: GenFile Viewer not work in version 12.1.SP4.53
142997 340768 Symptoms: When trying to view a generic file in SP4 Fix.53, the system crash.
Previous/Known workaround: No known workaround exists.
Solution: A correction is made to handle the fatal error.
341619 Title: Attachment angle name missing for stiffeners
Symptoms: The attachment angle in the generic file do not specify which stiffener
it belongs to (MARKING_NAME).
Previous/Known workaround: No kown workaround exists.
Solution: Corrected so MARKING_NAME will contain the stiffener number with
prefix "S".
143743 343050 Title: The angle of attachment is output overlapping at the same position.
Symptoms: On a twisted planar panel stiffener, the attachment angle markings are
overlapping.
Previous/Known workaround: No known workaround exists.
Solution: Adjusted to get attachment angles in correct end of twisted profile.

Hull Nesting:

Incident Issue Description


Number Number
107567 231463 Title: Table in Nesting Sketches not filled correctly by TBhook_Formula
Symptoms: A table in a nesting sketch did not continue in the next column when
the number of parts exceeded number of lines in table.
Previous/Known workaround: None
Solution: The table will continue in the next column with rule number + 2000.

Hull Weld Planning:

Incident Issue Description


Number Number
138476 324048 Title: Incorrect weld position
Symptoms: Weld position is wrong for some joint between a bracket and a
flange.
Previous/Known workaround: None
Solution: Weld position is now correct.
138954 325199 Title: Wrong bevel information in weld report
Symptoms: In the weld report some bevels were presented incorrectly
Previous/Known workaround: None
Solution: Bevel information in the weld report is now correct.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 131 of 517
Product Release Letter
Marine Drafting:

Incident Issue Description


Number Number
121631 271819 Title: It can't modify the layer number via 'General Note'
Symptoms: If the modal layer is changed, the "General Note" is not affected. It
still have layer 5.
Previous/Known workaround: No known workaround exists.
Solution: Layer handling of the General Note has been changed so the modal
layer will affect this note too.

Outfitting:

Incident Issue Description


Number Number
43243 69734 Title: Isodraft - Tee definition and representation
Symptoms: The representation of the isometric is very compressed.
Known workaround: None
Solution: If 'plain' weld is 'sandwiched' by Tee and Tube, do not delete the weld -
but change its SKEY to NULL. This is to avoid compressed representation.
60158 105940 Title: Cable Data - Load cables by start/end equipment zone -- no value
99227 213296 Title: Isodraft - ITEMCODE FOR SUPPORTS FROM STEX
Symptoms: When option ITEMCODE FOR SUPPORTS FROM STEX is set, if a
support has an STEX has a newline character, it does not show as two lines on
the isomeric BOM.
Previous/Known workaround: None
Solution: Allow item code to wrap if Item code contains a new line.
128185 289246 Title: Spec break shown at Pipe to Pipe connection
Symptoms: Spec break tag shown.
Previous/Known workaround: None
Solution: Remove spec break tag.
140201 329285 Title: Isodraft - Iso Dimension Error (InsulationControl & TracingControl)
Symptoms: Dimension errors were caused by InsulationControl and
TracingControl option (ON or ALL), together with drawing margin setting which
determines the sheet splitting location.
Previous/Known workaround: None
Solution: Handle page splitting correctly.
140619 332152 Title: Design - Moving cableway using model editor
Symptoms: Erroneous behavior when moving cableway using model editor.
Previous/Known workaround: Unknown
Solution: Cableway model editor now moves cableway and components
correctly.
141344 335023 Title: Design - Performance hit when the cursor is hovering over elements
Symptoms: On a slow connection to a server, the preformance deteriorates
Previous/Known workaround: N/A
Solution: Fixed.
142673 338662 Title: Design - Badly set up hangers cause crashes when checking weight
Symptoms: If the hanger tail is above the head, checking NWAI and similar will
cause a crash
Previous/Known workaround: Create a valid hanger
Solution: The application now returns weight 0 for such hangers.
142706 338938 Title: Isodraft - Check Valve flipped on isometric
Symptoms: Check Valve symbol flipped
Previous/Known workaround: None
Solution: Set 2nd digit of word 14 according to flow direction.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 132 of 517
Product Release Letter
12.1.SP4.53

PML Hull:

Incident Issue Description


Number Number
126242 283802 Title: Enhancement to run Console Applications(e.g sf416d) without login. For
more information see section Enhancements above.
136446 317303 Title: MarUtilDexPan class object cannot be called from PML.
Symptoms: See title
Previous/Known workaround: No known workaround exists.
Solution: The MarUtilDexPan object has been made available also from PML.

import 'marAPI'
using namespace 'Aveva.Marine.Design'
!obj = object MarUtilDexPan()

Hull Panel Line Control:

Incident Issue Description


Number Number
315689 Title: Incorrect adding of Excess in Assembly parts
Symptoms: Excess defined for piece part is added to both piece part and
assembly part in case assembly part does not have a specific excess defined
Previous/Known workaround: No known workaround exists.
Solution: If excess is defined on piece part and no excess is defined on assembly
part, then the piece part excess is now only added to the piece part itself.
The case when excess was defined for both piece part and assembly part worked
OK before and is not changed (i.e. piece part and assembly excess was added to
the piece part and assembly part excess only was added to assembly part.

Initial Design:

Incident Issue Description


Number Number
129493 293824 Title: Lonfitudinal Strength buoyancy diagram might be wrong at certain condition
(non-Uniform hull form)
Symptoms: Spikes in LS Buoyancy
Previous/Known workaround: N/A
Solution: The dents in hull form is taken care properly.
129490 326870 Title: Grain Calibration-full states
Symptoms: When the program calculates the Grain Calibration, the values of the
full states are higher than the values of the slack states.
Previous/Known workaround: No known workaround.
Solution: Hatch geomtry will be taken into consideration properly.

Planar Hull:

Incident Issue Description


Number Number
67282 129707 Title: When ppanpart, Marking of flange of I-bar is offset.
Symptoms: Marking of I-bars abbuting a planar plate is not at the correct location.
Known workaround: No known workaround exists.
Solution: Corrected so the marking on the plate will be at the correct location.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 133 of 517
Product Release Letter
Incident Issue Description
Number Number
133583 305024 Title: MarDrafting.ViewSectionModify does not work properly.
Symptoms: When create a new view by coping an existing view via MARAPI,
MarDrafting.ViewSectionModify does not work properly.
Previous/Known workaround: No known workaround exists.
Solution:
Shell profiles and the filters have been fixed. Only Current is actually only existing in
the GUI. It is a quick way to set up the following settings:

ShellCurves should be empty.


PanelsExclude =0
PanelsFilter should only contain the panel name.
BlocksExclude =0
BlocksFilter should be empty.
Assemblies should be empty.
ShellProfiles =0
ShellSeams =0
AutomaticSelection =0
DrawIntersections =1
DrawPlaneViews =1
DrawRSO =0
GAView =0
ViewType =0

This is visible if you create a view using only current and then create a new one by
picking the just created view. Only Current is then not checked, but the result is the
same.
134286 308475 Title: How to control panel name text size, Seam symbol size, Swage Symbol in
Symbolic View
Symptoms: Enhancement request to be able to control the size of the swage
symbol height.
Previous/Known workaround: N/A
Solution: The following keywords are now implemented. When set they will control
the height and colour of the swading symbols. When the value is 'NOT SET' this will
behave as before.

SWAGE_SYMB_COLOUR = <colour>
SWAGE_SYMB_HEIGHT = <height>
137072 318939 Title: If define the CUTOUT on profile, the trace position of profile is moved.
Symptoms: If define the CUTOUT on large profile, the trace position of profile is
moved on D views.
Other views are correct.
Previous/Known workaround: No known workaround exists.
Solution: The prolem has been solved so that the stiffeners are on the correct
location.
138637 324371 Title: The C length of syntax bracket will be removed if designating with negative
value.
Symptoms: C-measure on a bracket is lost in the Statement Wizard in case the
measure was a negative value.
Previous/Known workaround: Add the negative c-measure in the schema for the
bracket.
Solution: Corrected so also the negative values will be handled in the Statement
Wizard.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 134 of 517
Product Release Letter
Curved Hull:

Incident Issue Description


Number Number
40214, 69517, Title: Use bevel defined in seam checkbox set.
59315 103329 Symptoms: The checkbox was preinintiated as set
Previous/Known workaround: Not possible
Solution: It is now possible to use the Default Parameter
CPLA_USE_DEF_SEAM to control the tick box setting. By setting it to NO the
box will be unchecked from start when creating new plates.
116200 256045 Title: AM12.1.SP4.42 - colours of cplates need to be customizable
Symptoms: Colours on a CPLATE that is collected to a CPANEL have the same
colour as the panel. It is hard to differentiate plates from panels.
Previous/Known workaround: N/A
Solution: A new keyword, CPLATE_COL has been added to Curved Hull
Modeling that can be set to give collected CPLATEs a different colour. Default
colour is Green.
Other possible colours are:
BLACK
CYAN
BLUE
MAGENTA
RED
YELLOW
WHITE

Hull Structural Design:

Inciden Issue Description


t Numbe
Numbe r
r
64743 120367 Title: Set Default Box Limits
Symptoms: Selecting in Hull Structural Design the menu CURVED HULL -
DEFAULT - BOX pops up a window where the box limitations can be assigned. For
having a preview of the defined box, the button "SHOW" can be pressed. There is
no box shown, i.e. the SHOW functionality does not work.
Known workaround: No known workaround exists.
Solution: The problem has been solved so that the Default Box can be displayed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 135 of 517
Product Release Letter
Inciden Issue Description
t Numbe
Numbe r
r
134834 310035 Title: FEM Idealisation with incorrect result: Stiffener ends
Symptoms: -----
Previous/Known workaround: N/A
Solution: The option "simplify endcuts" has been added for Stiffener, Pillar, Flange
(faceplate) in the idealisation settings dialogue.

Hull Production:

Incident Issue Description


Number Number
36008 63074 Title: Jig information does not disappear in the curved panel view.
Symptoms: When creating a curved panel view that includes jig information and
then if uncheck (modify option) jig information, the jig information remains in the
curved panel view.
Previous/Known workaround: Create a new Curved Panel View.
Solution: The problem has been solved so that Jig information disappear when
modifying the view. This works for newly created views.
79589 168717 Title: Enhance to receipt drawings and generic file to also include the the inclination
value.
Symptoms: Inclination angle missing in generic file.
Previous/Known workaround: No known workaround exists.
Solution: The attachement angle for intersecting panels, intersecting brackets on
another panel and for stiffeners and brackets on same panel will now be shown
after the new keyword INCLINATION_ANGLE in the MARKING_DATA section of
the generic file from the Plate Interface.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 136 of 517
Product Release Letter
Incident Issue Description
Number Number
127069 286091 Title: Notch of P (S) only defined on SBP knuckled panel is output on both sides.
Symptoms: If the notch is supposed to be valid on only one side of a symmetrical
defined knuckled panel, it is still present on both manufacturing parts.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the notch will only be included on the valid part.
129712 293900 Title: Hull Mark corrections and improvements
Symptoms: Different results depending on the font used, text height and defined
reference position, left, middle, right etc…
Also defined the variable SBH_HOLEMARK_PART as 50, to increase accuracy of
resulting parts as described in user guide.
Previous/Known workaround: No known workaround
Solution: Arc tolerance is changed for hull marks to get better representation in
views
The marking of hull marks is changed. In case hull marking is plate, then a
projection is made, not development of individual curves within the hull mark.
The generation of the hull mark needs to be redone. New data is added to handle
the process.
Furthermore, in case hull mark name is given as <block>-<name>, the” block” is
picked up from the name and used when creating part names.
Part names are also given a position number automatically, based on the plate
numbering.
Marking on plate now has a correct identification as hull mark and can be
highlighted with colour (and later on with labelling).
The ppanpart process is modified to give correct labels and names. Furthermore,
not necessary messages are removed from the log file.
Interactive ppanparts (right-click in hull modelling) is now working as expected.
Previously it made changes to the hull mark object, preventing it from e.g. being
presented in canvas.
134940 310601 Title: Doubling plates not generated
Symptoms: Doubling plates not generated when without bevel definitions
Previous/Known workaround: None
Solution: Doubling plates are now generated correctly.
135914 315559 Title: The comment of hole in stiffener does not output to Gen.file.
Symptoms: The comment in the hole of a stiffener in Planar Hull is not included in
the generic file of the profile.
Previous/Known workaround: N/A
Solution: New keyword COMMENT added to profile generic file to be used for
profile hole comments.
136578 317683 Title: Attachment angles on inclined stiffeners
Symptoms: was marked only on one of the plates (in case stiffener was marking
more than one plate)
Previous/Known workaround: None
Solution: Now marked on all plates.
136481 317813 Title: Parameter D in profile sketches
Symptoms: A customer uses endcut 2000 with parameters 0, 0, 50, 50 to create
endcut for profile type 30. On detail view we can see right image but in profile
sketch we get wrong information.
The fourth paramenter is always shown as V1, but V1 is an angle and not a length.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that parameters A, B, C, D for endcut types 10 and 20 and
parameters A, B, C, D, E, F for endcut type 30 are shown in the profile sketch.
Generic file is not changed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 137 of 517
Product Release Letter
Incident Issue Description
Number Number
136941 318705 Title: In list file, the side of template is incorrect
Symptoms: List file always show number of templates OUTSIDE even if the
templates is inside
Previous/Known workaround: N/A
Solution: The output will now show if the number of templates is "OUTSIDE" or
"INSIDE".
137889 321221 Title: Problem for the planar hull makring line on the curved plate part to be
misaligned
Symptoms: When a planar panel is attached to the shell plate, the alignment of the
pmarking line is not correct.
Previous/Known workaround: The system is using the first planar panel plate (the
one defined as no=1) to get the thickness to adjust for. Make sure that plate number
one is the one that are attached to the surface.
Solution: Corrected so the marking will be aligned to the plate abutting the surface.
138648 325306 Title: Unexpected result after parts splitting
Symptoms: In some cases planar plates are not split correctly and an error was
reported.
Previous/Known workaround: None
Solution: Internal tolerances used during the splitting process have been adjusted
to produce a correct result.
138800 325594 Title: Incorrect angle of marking of abutting panel
Symptoms: Marking on a shell profile of an abutting panel has the wrong angle in
the profile sketch.
Previous/Known workaround: None
Solution: The marking for an abutting panel is now correct.
139014 325648 Title: Roll axes of developed plate is wrong dimenstion after running Bending
Template of PPI.
Symptoms: The distance to the roll axis 1 is not the same in the Bending Template
sketch as it is in the Shell Plate sketch after Cpanparts..
Previous/Known workaround: No known workaround exists.
Solution: The distance as it is, is correct but calculated from the same corner as
the other end of the roll axis.
The calculation is now changed to give the same result as in the Shell Plate sketch.
139083 325862 Title: Problem for the side of the bevel of the builtup shell stiffener to be upside
down
Symptoms: Problem for the side of the bevel of the builtup shell stiffener to be
upside down.
Previous/Known workaround: None
Solution: Bevel side calculation corrected in curved panel parts generation.
139299 326326 Title: When ppanpart, Marking of flange of I-bar is offset.
Symptoms: Marking of I-bars abbuting a planar plate is not at the correct location.
Known workaround: No known workaround exists.
Solution: Corrected so the marking on the plate will be at the correct location.
140159 330105 Title: Wrong hole position in curved profile sketch
Symptoms: A hole in a curved stiffener is drawn at the wrong position in the profile
sketch.
Previous/Known workaround: None
Solution: Holes are now drawn at the correct positions.
140202 330148 Title: Wrong marking side of panel and stiffener
Symptoms: The marking side of panel and stiffener is wrong in the profile sketch
for portside profiles.
Previous/Known workaround: None
Solution: The marking side is now correct.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 138 of 517
Product Release Letter
Incident Issue Description
Number Number
140210 330183 Title: Wrong jig plane for SB curved panel
Symptoms: When generating pin jigs for a SB specific curved panel the calculated
jig plane is wrong.
Previous/Known workaround: None
Solution: The jig plane calculation is now right also for SB specific curved panels.
141375 335320 Title: Attachment angles on knuckled plates
Symptoms: Attachment angle marking sometimes missing.
Previous/Known workaround: None.
Solution: Use this new fix release.

Hull Nesting:

Incident Issue Description


Number Number
76121 157887 Title: Nesting default file issue
Symptoms: On opening an old nest, when one or other of its defaults files
cannot be found. The nest is opened as “appears to be” normal, but in fact is now
using system defaults, thus may well result in an erroneous nest.
Known workaround: No known workaround exists.
Solution: In case an old nesting is opened and the corresponding default file(s)
are missing, a message will be displayed:
'Default file <file_name> does not exist! System defaults are used'
136723 318895 Title: Too many holes
Symptoms: If a nest on the raw plate, any parts with more than 500 holes, the
system shows an error "Too many holes". This happens only for the function
Plate Nesting > Nesting tool > Starts > Burn > All Holes.
Previous/Known workaround: Try and reduce the number of holes in a part to
less than 500.
Solution: Limit of 500 holes has been extended to 1000.
136941 319474 Title: Multiple nest open error
Symptoms: System error 2532 is given when trying to open multiple nestings.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so multiple nestings can be opened.
139096 325744 Title: Incorrect bridge shape after verification
Symptoms: The geometry of a bridge with a radius is not correct.
Previous/Known workaround: None
Solution: The geometry of a bridge with a radius is now correct.
139086 325760 Title: Lock U, Lock V don;t work in burning Bridge creation process
Symptoms: Despite information from Help "All bridges defined with two cursor
positions can be made either horizontal or vertical. This is achieved by giving
LOCK V or LOCK U before the second position is defined." this blocking function
doesn't work and Lock V and Lock V buttons are inactive.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the LockU and LockV is available when making bridge
with two positions.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 139 of 517
Product Release Letter
Hull Weld Planning:

Incident Issue Description


Number Number
136074 318790 Title: Bevel not reported in weld report
Symptoms: The bevel is not written in JntBev attribute and not written in Weld
Report (after detecting welds), if the joint is between a plane part and a shell
plate.
Previous/Known workaround: No known workaround exists.
Solution: Bevel codes for joints between curved and planar plates will now be
correct.

Marine Drafting:

Incident Issue Description


Number Number
135306 313156 Title: marAPI: ViewShellXNew doesn't work
Symptoms: ViewShellXNew method in MarDrafting Class doesn't work, i.e.
nothing happens when call it. System waits for some time and then gives zero
results.
Previous/Known workaround: No known workaround exists.
Solution: MarShellXViewOptions has been modified to handle creation of shellx
views better. By setting the bExceptXxxxx properties to 1 and having the
corresponding SelectXxxxx property empty will result in this type not being drawn.

Pipe Fabrication:

Incident Issue Description


Number Number
80255 171619 Title: The DPPTs in the Pipe Sketches are using for the DDNA Attribute PTAPs
instead of PIPCAs
Symptoms: NA
Previous/Known workaround: NA
Solution: Modified the code to consider the P3 point of the PTAP to mark the
dimensions and resolved the issue.
118409 263288 Title: Pipe Fabrication: there are cases when spool limits are ignored
Symptoms: See title.
Previous/Known workaround: No known workaround.
Solution: The existing code for the HT-HT/TH-TH connections considers the
branch members for checking conditions like shop=false/breaks conditions
instead of considering the spool members. Also, there is no condition available so
as to what to do if the member is a tubi on which checks are made. There may be
conditions like the branch members may be part of the other spool and we do the
wrong checking and the spools get merged. But modified and refactored the code
and fixed it.
121854 272808 Title: Pipe Fabrication "sees" a limit that does not exist.
Symptoms: See title.
Previous/Known workaround: No known workaround.
Solution: Issue got resolved along with
The existing code for the HT-HT/TH-TH connections considers the branch
members for checking conditions like shop=false/breaks conditions instead of
considering the spool members. Also, there is no condition available so as to
what to do if the member is a tubi on which checks are made. There may be
conditions like the branch members may be part of the other spool and we do the
wrong checking and the spools get merged. But modified and refactored the code
and fixed it.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 140 of 517
Product Release Letter
Incident Issue Description
Number Number
123408 276478 Title: Spool Fabrication Info not match with actual spool
Symptoms: NA
Previous/Known workaround: NA
Solution: Modified the code for the calculation of TURN value and resolved the
issue.
138062 322049 Title: Pipe Spool Failed in Marine Drafting
Symptoms: Creation of pipe sketches failed with an array error
Previous/Known workaround: None
Solution: This was an error which wasn't handled correctly.

Outfitting:

Incident Issue Description


Number Number
93205 199563 Title: Isodraft - Blind flange oddity
Symptoms: Isometric shows the dimension at blind flange at the head end but
not the tail end
Previous/Known workaround: None
Solution: Do not dimension blind flange at start of pipeline.
108966 235963 Title: Isodraft - ISODRAFT SKEY FY** is not working correct
Symptoms: Y-type filter not in correct orientation.
Previous/Known workaround: None
Solution: Do not force standout on a Y-type filter or its flow arrow.
134682 310475 Title: Isodraft - Duplicate tag and size shown at Tee or Olet with arrive at P3
Symptoms: Duplicate tag and size
Previous/Known workaround: None
Solution: Do not set Skey on 41 record when arrive at P3.
134065 311296 Title: Nominal Bolt table are not used for imperial bolt diameters when entering
Isodraft direcltly
Symptoms: Incorrect bolt diameters shown on isometric.
Previous/Known workaround: Invoke Isodraft from another module.
Solution: Initialise Nominal Bolt tables in Isodraft.
137427 322833 Title: Design - Category im[port giving errors
Symptoms: When an SCOM, element name contains an underscore character,
an error occurs when attempting to import elements from an Execl file.
Previous/Known workaround: Don't use underscores in SCOM names.
Solution: Added error handling.
138636 324135 Title: Isodraft - Check if 'virtual' tee when handling non-standard connection
items.
Symptoms: Partnumber is missing on isometric for non-standard connection
items.
Previous/Known workaround: None
Solution: Check if 'virtual' tee when handling non-standard connection items.
138004 328871 Title: Isodraft Material List Gridline Problem
Symptoms: If the cutting list option is ON, there is always an extra gridline
between the PT NO column and Description column even is "Material List
Gridlines" option is set OFF.
Previous/Known workaround: None
Solution: Take account of the "Material List Gridlines" option, when the cutting
list option is ON.
140577 333049 Title: Isodraft - IDF Weld record at Tee P3 causes error in SPOOLGEN
Symptoms: Missing fabrication Items in shop drawing and Shop MTO using
SPOOLGEN
Previous/Known workaround: None
Solution: Remove unnecessary Weld record from IDF.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 141 of 517
Product Release Letter
12.1.SP4.52

Assembly Planning:

Incident Issue Description


Number Number
132260 300266 Title: Make Hierarchy Selection and Make Selection - no visual output
Symptoms: The function is not producing any result.

Previous/Known workaround: Make manual selection.


Solution: Problem is corrected so the function will give expected result.

Planar Hull:

Incident Issue Description


Number Number
133321 304367 Title: Bevel Code info this side & other side displayed in Symbolic View
Symptoms: When using bevel names and they are to be included in the symbolic
views ()VIEWINFO, the side (this/other) is not considered.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that the view side will be checked and correct bevel name
is displayed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 142 of 517
Product Release Letter
Curved Hull:

Incident Issue Description


Number Number
134419 308309 Title: SB shell profiles by cyllinder stored at PS
Symptoms: Shell profile is defined as starboard only, by general cylinder. Default
box is Ymax=0, cylinder generator axis is Z, cylinder Y coordinates are on SB.
Resulting shell profile is on Portside!
Previous/Known workaround: No known workaround exists.
Solution: The problem has now been solved so that SB shell profiles by cylinder
is stored at SB.
135882 316825 Title: When recreate shell profile there come error 6521
Symptoms: When try to recreate shell profile error 6521 is given, this happen
only when surface is defined only to S-side.
Previous/Known workaround: Make the surface symmetric but only use SB
part.
Solution: The problem has been solved so that it is possible to create profiles on
the SB surface.

Hull Structural Design:

Incident Issue Description


Number Number
134835 310036 Title: FEM Idealisation with incorrect result: COR value for curves
Symptoms: when COR is used in the boundary of a panel that is refering an
internal curve, the FE Model makes the parallel displacement in the wrong
direction.
Previous/Known workaround: No known workaround exists.
Solution: The handling of COR values for curves during idealisation has been
corrected.

Hull Production:

Incident Issue Description


Number Number
224467 Title: W&COG drawing rule for Part Name $1010
Symptoms: To create new rule for getting Part Name in W&COG drawing form and
correcting latest documentation which shows
$1010 (table text rule)= Part name as defined in Part name Control. Used as the main
sorting key.
Which actually fetching Part ID.
CSV output shows Part Name and W&COG drawing shows Part ID by mismatching
the results.
Previous/Known workaround: N/A
Solution:
Corrected the documentation of current table text rule 1010 to be:
@1010 Name of production part.

Added table text rule 1015:


@1015 Part name as defined by Part Name Control.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 143 of 517
Product Release Letter
Incident Issue Description
Number Number
117436 259391 Title: How to control flange marking with endcut 1302?
Symptoms: There is a gap for the marking of the web on the flange when using
endcut 1302.

Previous/Known workaround: No known workaround exists.


Solution: The calculation of panel markings on flanges with overshoot has been
corrected. The drawing of flange markings on profile sketches has been modified.
127316 286910 Title: Wrong feed in lists and sketch with Bending Tab Method = M2
Symptoms: Result list produced by PROFNEST shows unreasonable results with
BENDING_TAB_METHOD = M2 set.
Used length is longer then length of the raw profile and sometimes there is a negative
rest length
Previous/Known workaround: No known workaround exists
Solution: Excess length calculation corrected.
130979 297831 Title: The hole position of curved stiffener is not correct after Ppanparts and Profile
Sketch and List.
Symptoms: See title
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that marking distances for holes, notches and cutouts are
created along the neutral curve.
131490 298557 Title: GSD Marking for stiffener on bracket is not created
Symptoms: GSD markings are made for the stiffener trace on the bracket but are
missing on the profile it self.
Previous/Known workaround: No known workaround exists.
Solution: This is now corrected so the GSD on stiffener brackets are included.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 144 of 517
Product Release Letter
Incident Issue Description
Number Number
132678 301288 Title: Unnecessary line is created when applying GSD for edge-reinforced stiffener.
Symptoms: A curved stiffener parallel to outer contour at a small distance procudes
one extra marking line that sometimes are outside the part.

Previous/Known workaround: No known workaround exists.


Solution: Extra marking line is removed.
135318 313185 Title: Marking for inclined panels is missing the name
Symptoms: MARKING_NAME in the marking block in the generic file is mising the
name of the abutting panel that is inclined marked to the plate.
Previous/Known workaround: No known workaroud exists.
Solution: MARKING_NAME for the inclination angle marking will contain the name of
the panel that causes the marking.
135781 315081 Title: Regression on ST001.exe in AM12.1.SP4
Symptoms: The flag indicating cutting direction is not correct. It shows zero.
Previous/Known workaround: No known workaround exists.
Solution: Corrected circulation direction information so that the same result will be
received in SP4 and SP5.
135916 315561 Title: The marking of plate is displayed outside the part.
Symptoms: When run profile sketch the flange attached to Kunckled panel,
The marking of plate is displayed outside the flange part.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that web marking lines and corresponding marking text will be
correctly drawn. Plane parts generation need to be re-run.

Hull Nesting:

Incident Issue Description


Number Number
135382 313569 Title: Nesting for profiles type 11 is wrong if profiles have an excess.
Symptoms: See title
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that profile type 11 is accepted in profile nesting.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 145 of 517
Product Release Letter
Marine Drafting:

Incident Issue Description


Number Number
130569 296373 Title: Symbol can not move when setting colors and layers.
Symptoms: If system is setup to use SVIEW_LT_COL and layers are defined
then when using "Symbolic View-->Planar Hull View-->Edit" the moved parts will
be reset everytime a ReCreate View is executed.
Previous/Known workaround: No known workaround exists.
Solution: The hull symbols or texts which are allowed to change position of can
now also be moved if SVIEW_LT_COL is assigned.
134049 306839 Title: Progressbar for Drafting(Model Insert, Slice and etc) makes system trouble
Symptoms: When a progress bar is up and user clicks on any element in the
Design Explorer or any other function, system will go into nonresponding mode.
Previous/Known workaround: Do not click anywhere unil progress bar is
finished.
Solution: Corrected so the system will not recognise any commands from user
until progress bar completes.

Mechanical Equipment Interface (MEI):

Incident Issue Description


Number Number
317338 Title: bad picks of GENPRI (eg in measure)
Symptoms: Some picks of GENPRI imported from STP or IFC files chose the
wrong position.
Previous/Known workaround: None
Solution: This has been fixed. We recommend using "Graphics/Cursor" pick
options when trying to pick exact points on GENPRI.

Outfitting:

Incident Issue Description


Number Number
37978 69387 Title: Isodraft - Upside down VC** Skey
Symptoms: Upside down VC** Skey
Previous/Known workaround: None
Solution: Test was wrong way round.
55248 99425 Title: Isodraft - User defined iso symbol is not getting the correct orientation,
whatever settings
Symptoms: User defined iso symbol is not getting the correct orientation,
whatever settings.
Known workaround: None
Solution: Test was wrong way round.
67611 134240 Title: Isodraft - WELD table new numbering for every sheets of same PIPE
Symptoms: Currently, all WELD numbers were sequenced through all ISO
sheets which from same PIPE.
Known workaround: None
Solution: Introduce option to allow User to specify Weld numbering
PER/ACROSS sheets.
68871 138074 Title: Isodraft - Weld report with "GENERATED"
Symptoms: Cannot produce weld report with "GENERATED" welds.
Known workaround: None
Solution: Allow weld report for "GENERATED" welds.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 146 of 517
Product Release Letter
Incident Issue Description
Number Number
81716 181747 Title: Isodraft - Fault dimension in isometric when using reference dimensions
Symptoms: Fault dimension in isometric when using reference dimensions
positioned between tubes.
Previous/Known workaround: None
Solution: Handle Reference Dimension positioned between tubes.
89510 191655 Title: Isodraft - Isodraft mto part list error
Symptoms: Incorrect bores against Y-type Tees.
Previous/Known workaround: None
Solution: Cater for 'nested' Y-type Tees.
98574, 211461, Title: Isodraft - #PDMS #ISODRAFT #ISOOPTION #CHNAGE HIGHLIGHTING
122728 274943 #ATTA
Symptoms: Generated Iso drawing is different information, depends on change
highlighting option (Comment Atta - Stext / Ptno positions are not same)
Previous/Known workaround: None
Solution: Handle highlighting records correctly when processing hangers.
110543 240403 Title: Piping - Error when creating a component with no leave tube available in
the specification
Symptoms: An error would occur when creating a component in the component
creation piping form when there was no leave tube available at the leave bore
size in the specification.
Previous/Known workaround: None
Solution: Handled the error and displayed an appropriate warning allowing
creation to continue.
110598 240676 Title: Piping - Error occurred in Component Creation form when no suitable
adjacent components are available.
Symptoms: There were no suitable adjacent components available for example
when creating a valve with adjacent components tick box selected then an error
would be displayed and creation would terminate.
Previous/Known workaround: None
Solution: The error has been handled, an appropriate error message is
displayed and creation continues as normal.
121468 271169 Title: Piping - Error creating BEND if TAIL different bore than HEAD
Symptoms: If you tried to create a bend in the component creation form when
the head and tail of the branch had different bore sizes and there was no LSTU
for the tail bore size in the specification then an error would display.
Previous/Known workaround: None
Solution: The error has been handled correctly and creation is allowed to
continue.
128804 290929 Title: Piping - Shop attribute not being set correctly when using the word FALSE
in the spec instead of FALS
Symptoms: When re-selecting a piping component using the component
selection form the shop attribute was not being set correctly if the user had set
the shop flag to 'FALSE' in the spec instead of 'FALS'
Previous/Known workaround: Change the spec to say 'FALS'
Solution: Made it so the component selection form now recognises both 'FALS'
and 'FALSE'.
133207 303391 Title: Spooler - Mitred bend weights not included in Brweight and Nweight
calculations
Symptoms: Mitred bend weights not included in Branch weight
Previous/Known workaround: None
Solution: Calculate mitred bend weights.
132317 304864 Title: Piping - Component creation slow when branches with many ATTAs are on
the screen
Symptoms: Slow performance.
Previous/Known workaround: Remove branches with many ATTAs from the
screen.
Solution: Restrict ATTABREAK refresh to current branch.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 147 of 517
Product Release Letter
12.1.SP4.51

Planar Hull:

Incident Issue Description


Number Number
109889 238247 Title: OVELAPs can not be kept when the CLIP is attached on the non-mould
side of plate with auto bevel
Symptoms: GAP_M, GAP_N and GAP_T does not take the material in
consideration when the clip is placed.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so GAP_M, GAP_N and GAP_T is taken the material in
consideration when the gaps are calculated.
118758 264096 Title: Problem not to generate the knuckled panel with the specific distance from
the internal seam
Symptoms: When creating the knuckle panel from two planar panels, if a panel
have the specific distance (less than 870mm) from the knukled limit to the internal
seam, it's not genereated.
If the distance from the knukled limit to the internal seam are more than 870mm ,
it’s properly made.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the knuckled panel will be generated also when the
distance is less that 870 mm.
121474, 271182, Title: Marking of free text in Hull Modelling
69305, 138100, Symptoms: Various problems with Free Text Marking when presentign on
75063 154185 different sides of the panel.
Previous/Known workaround: No known workaround exists.
Solution: The definition data for marking of free texts in panels consists of a
point and an angle (u,v,t) which defines the base line of the text.
Texts are then displayed in views and on plate parts. A problem occurs when a
text shall be presented on the “other side” (e.g. when looking direction is changed
on a view). We cannot present texts mirrored and this wouldn’t be a meaningful
presentation to the user either. Instead, the text needs to be presented in a
readable way.
Normal behaviour is to have the text (or actually the text box) to the left of the
base line vector (of text). However, since transversal structures are normally
worked at in views looking forward, the viewing direction and the normal of the
panel are in opposite directions. The uv coordinate system is "turned". The
function to add marking texts is considering this and presents texts as indicated in
the view, but from a design language perspective (the scheme) it generates texts
on the right side of the base line vector and also possibly using another point
within the text box as starting point for the text.
307189 Title: Check for bevel overlap in WELD stmt
Symptoms: Check for overlap bevel definition when creating weld statement
Previous/Known workaround: N/A
Solution: When a WELD statement is created/run, it is checked so threre are no
overlaps.
In case of an overlap, an error will be set and user be notified.
Error code 6640 will be set "Overlaping weld and bevel definitions not allowed."
134167 307379 Title: If CUTOUT type contains a TYP= character , the excess is not displayed in
the scheme editor.
Symptoms: Excess 2 (EX2) for clips is lost in schemas.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that the excess (EX2) value will now remain in the
statement.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 148 of 517
Product Release Letter
Incident Issue Description
Number Number
134168 307382 Title: If an error occurs CUTOUT statement, the hole is removed for an unknown
reason.
Symptoms: When run all statements and an error occur in the cutout, some
holes are removed.
Previous/Known workaround: Run statements one by one.
Solution: Corrected so hole stays even after erroneous cutout statement.

Hull Structural Design:

Incident Issue Description


Number Number
134470 308618 Title: RSO Import
Symptoms: Problems when importing RSO (XML) in 12.1.SP4.49 and
12.1.SP5.9. THey simply don't import.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the ROS's will be imported.

Hull Production:

Incident Issue Description


Number Number
132554 300913 Title: GSD Marking for stiffener on bracket is not created
Symptoms: For bracket syntax 7, no GSD's are added to the resulting plate part.
Previous/Known workaround: No known workaround exists.
Solution: In case the bracket is referring to a planar panel surface in syntax 7,
the GSD's will be added.
133049 302771 Title: The GSD of Flange does not considered on out of panel.
Symptoms: when a welded flange is defined to stop outside the panel limit, the
GSD on the flange is not adjusted to the GSD on the plate.
Previous/Known workaround: No known workaround exists.
Solution: Plane panel parts generation has been corrected so that the distance
to flanges starting or ending outside panel contour will now be considered when
creating GSD-markings on plates.
133396 304245 Title: Configuration information profile number in profile cutting format
Symptoms:
Partnames according to level TBRPROF_CUTINT in Profile Cutting interface are
currently only used for the name of the part that caused markings.
Previous/Known workaround: N/A
Solution: The partname rule level selection has been corrected for the Profile
Cutting Interface.

Steps to get profile names in the profile nesting receipt sketch created when the
Profile Cutting Interface is run:
- Create a name rule for TBRPROF_CUTINT (tb_partname_level.def)
- Define the rule in the partname control file and run inithull (tb_partname_ctrl.dat)
- Customise the partname in _TBhook_CustPartname.py in directory
...\Vitesse\Lib
- Run planar panel parts generation, profile nesting and profile cutting interface.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 149 of 517
Product Release Letter
Hull Nesting:

Incident Issue Description


Number Number
130120 295217 Title: PLCM Raw Plate Calculation is Wrong
Symptoms: When trying to use PLCM system calculate Raw Plate as minumum
box around Plates and ignores Raw Plate dimensions given by user. So that it is
not possbile to add Start for Burn so that can not create PLCM nesting output.
Previous/Known workaround: No Known workaround exists
Solution: Correction for calculating requiered raw plate size has been done then
part excess are missing on the outer limits of the assembly part.
132917, 303781, Title: Marking lines colous for TS and OS bending
132969 304067 Symptoms: When nesting knuckled flange converted to a plate, marking colours
for bending are shown wrongly.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that if MARK_BEND_SIDE = BOTH the marking will be
put on both sides else if MARK_BEND_SIDE =REFLECTED the marking will be
put on the side opposite to the side on which pressure is applied otherwise the
marking will be put on the side on which pressure is applied.

Marine Drafting:

Incident Issue Description


Number Number
131603 298941 Title: Can not query the pos of mwled in marine drafting
Symptoms: Using the command: Q POS, in Marine Drafting on a MWELD
element will crash the system.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the Q _POS will return a proper result in Marine Drafting.
133639 305433 Title: Highlight colour of selected model does not show when using Tools-Model
Copy function.
Symptoms: If we create a new symbolic view at first time, highlight colour of
selected model does not show when using Tools-Model Copy function.
There is no problem if recreate an existing view.
Previous/Known workaround: Recreate the view.
Solution: Fixed so no recreation is needed after first creation of the view.

Pipe Fabrication:

Incident Issue Description


Number Number
114023 250069 Title: No spooling via "Asfbreak, Lsfbreak" attribute in Weld Type
Symptoms: The spools are not automatically generated, when
ASFBREAK/LSFBREAK is set on a WELD.
Previous/Known workaround: None
Solution: To enable this feature, just add the following line in the evars.bat:
set ENABLEBREAKSONWELD=TRUE right under the set
PRODUCTIONCHECKSENABLED=FALSE declaration.
121854 272808 Title: Pipe Fabrication "sees" a limit that does not exist.
Symptoms: Not able to define spool breaks if the branches are connected in
HEAD-HEAD and TAIL-TAIL fashion.
Previous/Known workaround: Developed a code that does the action.
Solution:
Issue got resolved along with
Resolved the issue. Now, both Head-head and Tail-Tail connections work fine.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 150 of 517
Product Release Letter
Outfitting:

Incident Issue Description


Number Number
118379 263168 Title: Interfaces - rvmexport - elements imported via ifc gets incorrect shape in
rvm file
Symptoms: Some IFC files imported into E3D 2.1 and then shared with PDMS
were drawn and exported with the wrong position and or orientation.
Previous/Known workaround: No known workaround exists
.Solution: This issue has been fixed in PDMS.
129876 294340 Title: Interfaces - IFC model explodes during Review export from PDMS
Symptoms: Some IFC files imported into E3D 2.1 and then shared with PDMS
were drawn and exported with the wrong position and or orientation.
Previous/Known workaround: No known workaround exists
Solution: This issue has been fixed in PDMS.
128693 295250 Title: Equipment - MEI Import reported failure when licence about to expire
Symptoms: An error message when importing a file when the licence was very
close to expiry.
Previous/Known workaround: Ignore the error message (the import did
happen).
Solution: The error/warning handling has been improved.
130169 295710 Title: Isodraft - System Isometric error with multiway PCOM
Symptoms: Loop is not closed.
Previous/Known workaround: None
Solution: Only insert dummy component if end connection is set.
135725 314961 Title: Isodraft - Only 20 non-Standard branch connections are allowed
Symptoms: (33,872) Maximum of 20 Non-standard connections exceeded
Previous/Known workaround: None
Solution: Increase limit to 999.

12.1.SP4.50

Planar Hull:

Incident Issue Description


Number Number
91001 196644 Title: Scheme Editor need to be improved
Symptoms: When using the "Run All" command in the Schema Editor and a
warning is given, the system does not stop at the statement where the warning
was given.
Previous/Known workaround: No known workaround exists.
Solution: A possibility for the user to stop a schema when all statements are run
and a warning is given, has been implemented.
A new default keyword has been added to control the error level for the "Run All"
command.
STMT_RUN_ALL_BREAK = <level>
<level> is either ERROR (default) or WARNING.
In case of WARNING, the execution will also stop for errors.
102130 219665 Title: Named stiffener ends are ignored when panel/scheme is recreated
Symptoms: Using named connections (__SBED_STIFF_ENDS__) for a stiffener
end will be lost if the function Panel Recreate is used.
Previous/Known workaround: No known workaround exists.
Solution: Solved so the named connections will remain also when panel is
recreated.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 151 of 517
Product Release Letter
Incident Issue Description
Number Number
105439 226457 Title: If Input decimal point to first place for seam bevel, but the decimal part of
bevel is ignored.
Symptoms: When specifying the bevel for an internal seam as Code, Variant
and e-measure where the e-measure contains a decimal e.g. 10.5, the decimal
part is ignored and truncated (in the example to 10).
Previous/Known workaround: Manually update in the schema file and rerun the
seam.
Solution: The decimal will now remain also after modify etc.
127446 287267 Title: Wrong position of profile types 60 and 70 modelled as stiffeners.
Symptoms: Difference in profile location appear between hull symbolic view and
3D view.
Previous/Known workaround: No known workaround exists.
Solution: For profile types 60 and 70 modelled as stiffeners there are no
specified
defintion or location point in contrast to pillars. So what is correct in
this case is unclear. Normally those types are made as pillars. The change
made takes into consideration of making least harm to existing customers.
For them the symbolic view is most important and is not changed.
129216 292431 Title: A fatal error occur when deleting the planar panel through Plane Panel
Selection Tool.
Symptoms: The Fatal error only happens when indicating a block that is empty.
Previous/Known workaround: Make sure that the block to indicate contains at
least one panel.
Solution: Corrected so empty blocks will be handled in selection tool.
130917 297283 Title: An error occur if running the scheme in CUTOUT that refer to the other
panel after panel split.
Symptoms: Cutout statements for a panel that has been split gives error.
Previous/Known workaround: The reference is not correct for this profile in the
cutout stmt. Manually change to correct profile reference.
Solution: Corrected so references are correctly updated by the system when a
panel is split into two panels.
131601 298831 Title: VUG Notch is not correct on slant case.
Symptoms: When making an VUG corner notch and the corner is not a 90
degree corner, the C measure is not correct in the resulting notch.
Previous/Known workaround: No known workaround exists.
Solution: The VUG notch will get the correct dimension also in case of inclined
boundary condition.
129315 299234 Title: A fatal error occurs when running scheme on WEL statement.
Symptoms: After reverting a knuckled panel into ordinary panel, a refering panel
may crash if only the weld statemetn is executed.
Previous/Known workaround: AS the references are changed, the boundary of
the abutting panel must be changed. As a consequense, also the weld statement
may have to be changed. After the panel has been updated, it will run without
failure.
Solution: If not the workaround is used, an error, 6047 - Panel missing, will be
given.
132574 301019 Title: Long quality name causes an error using statement wizard. Valid for clips
only
Symptoms: See title
Previous/Known workaround: Use shorter quality names.
Solution: The quality name for clips can now be as long as in other places.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 152 of 517
Product Release Letter
Incident Issue Description
Number Number
133702 305435 Title: The weight is not calculated correctly accoding to endcut of curved
stiffener.
Symptoms: The weight of the HSTIFF is to correctly calculate for curved
stiffeners. However, the MPROF weight is correct for the curved stiffener.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the endcuts will also be taken in consideration when the
stiffener (HSTIFF) is a curved stiffener.

Curved Hull:

Incident Issue Description


Number Number
128657 290517 Title: CHM, UPD_NOTE_DEFAULT cannot be set in sh700.sbd
Symptoms: UPD_NOTE_DEFAULT cannot be set in sh700.sbd or interactively
in CHM.
Previous/Known workaround: No known workaround exists.
Solution: UPD_NOTE_DEFAULT can now also be set in sh700.sbd and
interactively within CHM context.

Hull Production:

Incident Issue Description


Number Number
94012 200817 Title: Mounting angle of the panel across the seam does not appear on plate.
Symptoms: If a panel is split into several patts and there is a marking for
an abutting inclined panel, the attachment angle information is only marked on
the part that is holding the midpoint of the total panel marking.
Previous/Known workaround: N/A
Solution: Marking of attachment angle now added to all plates intersected by the
inclined panel.
116062, 255785, Title: The developed shape of bow plate is strange(Not Good). For more
123467 276642 information see section Enhancements above.
124500 279486 Title: OSP: Material quality is not transferred in case of STCN and GENSEC
Symptoms: When generating parts via Hull PPI of SCTN's or GENSEC's, the
Material Quality, Grade, is not transfered to the part.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so manufacturing parts will get the defined grade.
127690 288149 Title: Settings for fictious notches not working properly
Symptoms: It is hard to see if a notch is a fictious or real notch in the receipt
drawing from ppanparts.
Previous/Known workaround: N/A
Solution: A new keyword to ppanparts has been added.

MARK_COLOUR_FICT

By adding this to ppanparts.ip, the fictious holes and notches will be drawn in the
specified colour.
129713 293933 Title: Problem that the position of the holes to be compensated for shrinkage is
wrong
Symptoms: If SHRINK_HOLES are not included in ppanparts.ip, the holes are
moved in the plate in case of shrinkage is applied.
Previous/Known workaround: No known workaround exists.
Solution: When the hole is not to consider any shrinkage, the reference position
was previously as the starting position of the geometry but is now changed to be
the center of hole area which means the hole will keep the position and not be
moved. This is if the ip SHRINK_HOLES is missing in the ppanparts.ip file.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 153 of 517
Product Release Letter
Incident Issue Description
Number Number
130836 296998 Title: Profile sketch rule text $4046 does not show value in Imperial Units
Symptoms: Profile sketch rule text $4046 does not show value in Imperial Units
Previous/Known workaround: No known workaround.
Solution: The profile sketch rule text $4046 corrected so that it will show weight
in imperial units if keyword WEIGHT_UNIT=LB in SBH_SKETCH_RESTRICT file.
131715 299047 Title: How to remove GSD Marking for center line
Symptoms: System autmatically adds GSD's for the center line in parts crossing
the center line. Request is to be able to surpress those GSD markings.
Previous/Known workaround: No known worksround.
Solution: A new keyword, MARK_CL, has been introduced to the GSD default
list.
The keyword may have one of the two values:
YES GSD's will be marked for the intersecting center line (this is default if
keyword is not given)
NO No GSD's will be marked for intersecting center line.
300457 Title: SHI- Weld Estimation. For more information see section Enhancements
above.
132625 301110, Title: SBH_PROF_EXC_MOVE incorrectly changed
303598 Symptoms: A fix in 12.1.SP4.47 for SBH_PROF_EXC_SHRINK accidently also
affected SBH_PROF_EXC_MOVE.
Previous/Known workaround: No known workaround exists.
Solution: Updates made to revert the changes for SBH_PROF_EXC_MOVE.

Hull Weld Planning:

Incident Issue Description


Number Number
132044 299654 Title: If the assembly name contains () characters, a fatal error occurs when
create a weld.
Symptoms: Use of special characters make the system to abort.
Previous/Known workaround: Use ony a-z, A-Z, 0-9 and _.- (underscore, dot
and minus).
Solution: Changes made so that Assembly Planning accept only following
characters in assembly name.
a-z
A-Z
0-9
_.-

Marine Drafting:

Incident Issue Description


Number Number
129661 297491 Title: Additional API requests
Symptoms: Request for two new API:
1. Insert -> Drawing Form
2. File -> Transfer
Previous/Known workaround: N/A
Solution:
1: Api function FormInsert( string formName) implemented.
If a form already exists in the drawing, it will be exchanged.
2: Api function SubpictureTransfer( MarElementHandle SubpictureHandle, string
TargetDrawingNme, int PositionCode) implemented,.
The target drawing must exist on DB and the position code is the same as in
interactive function (optional, default is "same as in source drawing").

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 154 of 517
Product Release Letter
Incident Issue Description
Number Number
132345 300308 Title: System freezes due to addition click into symbolic view by user
Symptoms: Immediately after pressing the "OK" button of the symbolic view form
to change the content of a symbolic view, by mistake the designer clicked once
again into the the symbolic view. The system then "freezes", which means that it
is afterwards not possible anymore to call any function except exit.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the "by mistake" click will not freeze the application.

Pipe Fabrication:

Incident Issue Description


Number Number
87408 186418 Title: 12.1.SP4.27 - Wrong highlight in 3D view when selecting item for Multiple
Spooling
Symptoms:
Previous/Known workaround: N/A
Solution: The problem of highlighting arises when the Multiple spool form is
active along with the Modify Spool form. The TRACKCE in the Modify spool form
does an UNENHANCE action due to which the highlight that is suppose to
appear after picking the component(through pick option in Multiple Spool form) is
not being seen.
304974 Title: 12.1.SP4 Fix50 : An error message displayed while navigating to any
element in design explorer(except piping) while using modify spool form-
(2,751) Variable !!PFSPLITMERGESPOOLS
Symptoms: The reported error pops up whenever you try to navigate,if the form
!!splitmergespools is not defined but modify spool form is opened only.
Previous/Known workaround: Tweaked the code to handle the error.
Solution: The error pops up because of the form !!splitmergespools is not
defined (which is being used in the code.Resolve it.

Outfitting:

Incident Issue Description


Number Number
69853 140765 Title: Isodraft - Y type strainer SKEY "FYFL" has no Flanged-end shape
Symptoms: Y type strainer SKEY "FYFL" has no Flanged-end shape
Known workaround: None
Solution: Show flanges on Y'-type Filter/Strainer.
93892 200614 Title: Isodraft - Isometric Fails - vertical pipe containing seton tee with skey
HCBW
Symptoms:Isometric Fails with doubleback pipe if there is a zero-length set-on
tee.
Previous/Known workaround: None
Solution: If this is a zero-length set-on tee then suppress doubleback pipe
checking.
96671 207081 Title: Spooler - Mitred bends numbered incorrectly
Symptoms: Mitred bends and their leave tubes numbered incorrectly in SPLTBL
Previous/Known workaround: None
Solution: Correct mitred bend part numbering.
112297 244609 Title: Spooler - No weight shown for mitred bend tube in material list
Symptoms: No weight shown for mitred bend tube.
Previous/Known workaround: None
Solution: Write weight record for mitred bend tube.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 155 of 517
Product Release Letter
Incident Issue Description
Number Number
112829 246231 Title: Isodraft - Missing break on crossing lines/branches
Symptoms: Missing break on crossing lines/branches
Previous/Known workaround: None
Solution: Allow Tee/Bend Elbow to be stretchable if not preceded or followed by
tube.
298242 Title: Design, Cats & Specs - When SDTE with SKEY 'RESW' Shows error
message on modifying in catalogue
Symptoms: When SDTE with SKEY 'RESW' Shows error message on modifying
in catalogue
Previous/Known workaround: None
Solution: Need to add 'RESW\Socket Weld Eccentric Reducer' to file
\PDMSUI\dflts\ui-skey-redu.
131714 299247 Title: Piping - Large nominal bore tables cause fatal errors in Paragon
Symptoms: If the nominal bore table contains more than 200 entries, using the
Specification form in Paragon will crash.
Previous/Known workaround: Use nominal bore tables with less than 200
entries.
Solution: The fatal error has been prevented but the values returned by
nombmm and nombin are truncated after the first 200 entries.

12.1.SP4.49

Planar Hull:

Incident Issue Description


Number Number
126659 284883 Title: Enhancement to divide SBH_MARKING_SURF_TOL into Overlap and Gap
Symptoms: N/A
Previous/Known workaround: N/A
Solution: Two new variables have been implemeted to make it possible to
control the abbuting panel tolerance for marking.
SBH_MARKING_SURF_TOL_OVERLAP and
SBH_MARKING_SURF_TOL_GAP. If given they will take precedense of the
marking tolerance given by SBH_MARKIKNG_SURF_TOL. If given non
numerical values, the default overlap will be 16 mm and gap 2 mm.
127887 288336 Title: After re-create panel, Cutout shape is strange with M1(width).
Symptoms: Addign a cutout with an M1 value works fine. After using the function
re-create, the M1 value is still there but also parameter C has been added by the
system.
Previous/Known workaround: Manually remove the parameter C to get a
correct cutout.
Solution: Corrected so the M1 value will remain and there will be no C value
when recreating the planar panel.
128463 290340 Title: It does not correctly along the shape of the chamfer of the panel that
abutting in a specific case.
Symptoms: In case of bevel type 41 variant 2, when referring a boundary to such
section, the bevel is not compensated correctly for the bevel.
Previous/Known workaround: No known workaround exists.
Solution: Problem with the bevel type 41 variant 2 is solved and the boundaries
of abutting panels will be correct.
128766 290801 Title: Imperial units - Angles on point definition form
Symptoms: Angles were translated to imperial units
Previous/Known workaround: No known workaround.
Solution: Angles will no longer be translated when imperial units are used.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 156 of 517
Product Release Letter
Incident Issue Description
Number Number
129532 293317 Title: Excess given as Imperial units
Symptoms: Previously not accepted.
Previous/Known workaround: Use metric.
Solution: Accept imperial units when adding excess.
129687 293862 Title: Imperial units when adding hooks in hole
Symptoms: Percentage handled as imperial unit
Previous/Known workaround: No known workaround.
Solution: Hooks in holes now correctly handled in imperial unit project.

Curved Hull:

Incident Issue Description


Number Number
68585, 135739, Title: Curved panel is not getting created for cylinder
41569, 69599, Symptoms: It is possible to create a cylindar shepd shell plate but not to add this
57244, 96702, plate to a curved panel for further processing.
89058, 190897, Known workaround: No known workaround exists.
92856, 198972, Solution: Cylinder plates can now be created and added to a Curved Panel for
94827, 202779, further process in cpanparts. There will be not templates or jigs produced for such
109564 237543 Curved Panel.
124983 280744 Title: Notch in SB Shell profile from sym seam doesn't show up in Manstiff list
and Gen file
Symptoms: Notches in SB specific shell profiles created via REFL seam with
symmetrical seams doesn't show up in Manstiff list and not in gen file from Profile
Cutting interface nor "Profile sketch and list" and so cannot be produced.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that notches, at reflected seam positions, will be created
when CPanGen is run.
128728 290679 Title: Shellx over/CL has wrong line type on SB
Symptoms: When the keyword DIN is set in the Hull Modelling default file and a
ShellX view is created that extends over CL, the SB markings are seen as
dashed dotted as for PS it is solid lines. The SB marking should be the same as
for PS.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved for the SB side and OverCL drawing
when DIN is set.
128870 291356 Title: Surface Manager surface with curves, the curves cannot be used anymore
as seams
Symptoms: Since release of 12.1.SP4 Fix.43 the curves that are released from
Surface Manager will not contain the surface name. This is due to name length
restrictions. This resulted in some places in the system could not find those
curves anymore.
Previous/Known workaround: No known workaround exists
Solution: Corrected so both curves released prior to SP4 Fix.43 and curves
released after SP4 Fix.43 will be found by the system.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 157 of 517
Product Release Letter
Hull Production:

Incident Issue Description


Number Number
93615 200153 Title: Enhancement request for curvature control of shell stiffeners
Symptoms: After Cpanparts, Shell stiffener will be stored as curved or straight
on the profile data bank via SBH_SHELLPROF_BENDING_CTRL.
In METHOD of control file, only possible using PER_1000_FACT.
A more flexible way is needed to control this.
Previous/Known workaround: N/A
Solution: A new method PER_XXXX_FACT has been added to the /METHOD
keyword.
Also a new attribute /PER_FACT_DIST is added and it takes one paramenter
which is the distance to use instead of the fixed 1000 mm.
105189 225613 Title: An unnecessary TWIST_ANGLE in the Pillar is applied to the GEN file after
Profile Sketch.
Symptoms: In the generic file, the TWIST_ANGLE may appear as 1.57 when it
is supposed to be 0.0.
Previous/Known workaround: Manually modify the generic file and set
TWIST_ANGLE=0.0
Solution: Corrected. 1.57 is the radians representation of 90 degrees and should
not be presented in the generic file. As there is no twisting, 0.0 is supposed to be
assigned to TWIST_ANGLE.
116063 255786 Title: The marking of Planar panel does not clear in bow plate part.
Symptoms: Marking of planar panels on curved plates over CL is not symetrical.

Previous/Known workaround: No known workaround exists.


Solution: Updated to generate correct curves.
128871 291357 Title: Nesting sketch Rule $3014 shows wrong value, if project is set with
Imperial units.
Symptoms: Strange value of area is presented.
Previous/Known workaround: No known workaround exists.
Solution: Correctection made for the rule 3014 so it shows the expected area.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 158 of 517
Product Release Letter
Surface Manager:

Incident Issue Description


Number Number
110236, 239304, Title: Curve name length problem with surface manager.
129544 293627 Symptoms: Surface Manager combines simply the surface name and curve
Name to a single name. Even the resulting Name has more than 24digits then
AM simply store it on Dabacon. The curved hull user is then not able to use that
curve. The system will give a message that the curve does not exists.
Previous/Known workaround: Make sure the surface names in Surface
Manager are short so the combined name is maximum 24 characters.
Solution: The prefix containing the surface name is skipped to avoid too long
names. It is up to the user to keep track of the curve names so there is no clash
with other already existing curves.
The same applies for Surface & Compartment.

Marine Drafting:

Incident Issue Description


Number Number
31923 61359 Title: Hull Drafting: Edit>Delete>Part of Dimension makes linear dimensions un-
associative
Symptoms: Using Edit>Delete>Part of Dimension function, the LDIM element is
completely removed, dimension become just a subpicture containing geometries
and losses its associativity to the design elements.
Previous/Known workaround: No known workaround exists.
Solution: When deleting a part of a dimensioing, the resulting parts will remain
persisted if the original dimensioing is
(currently applicable on linear dimensionings).
102040 218924 Title: Free placing of diameter and radius dimension texts
Symptoms: A diameter or radius dimension text can only be moved perpendicual
to the dimension line (the text is always aligned with the dimension line).
Previous/Known workaround: No known workaround exists.
Solution: Diameter and radius dimension text can now be moved also parallell to
reference line in the interactive function Modify Dimensioning/Move Dimension
Text. This means that the text can be moved "freely". However, for dimensionings
of type Straight, Knuckled and Cross with text outside, the offset cannot be
negative (while it can for type Cross with text inside).
During positioning of the text, the user is guided by dynamic highlighting.
275609 Title: Possibility to ignore dimension arrows when deriving available space for
dimension text. For more information refer to section Enhancements above.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 159 of 517
Product Release Letter
Incident Issue Description
Number Number
289070 Title: Dynamic highlighting when creating/updating dimensionings
Symptoms:
When creating or updating dimensionings interactively there is a need for
dynamic highlighting of the result.
E.g. when creating a linear dimensioning, the resulting dimensioning should be
highlighted during each user supplied measure point. This will make it clear for
the user what the result will be.
Previous/Known workaround: N/A
Solution:
Dynamic highlighting has been implemented

-When supplying each measure point in Linear 2d/3d Dimensioning creation


-When locating the dimension line in Linear 2d/3d/Axis Parallel Dimensioning
creation
-When locating the leader line in Radius/Diameter Dimensioning creation
-When moving radius/diameter text in Modify/Dimension/Move Dimension Text
function
-When moving the dimension line in Modify/Dimension/Move Dimension Line
function
-When changing witness line direction in Modify/Dimension/Slant Witness Line
function

Also, some other improvements:


-Snapping to cardinal axis during "Modify/Dimension/Slant Witness Line" now
also in 3D.
-When checking placement for “text outside” in Linear 2d/3d Dimensioning
creation, no need for user to indicate side explicit (during location of dimension
line, the hair-cross position gives the wanted side)
-When creating Axis Parallel dimensioning, side for text is now derived when
locating the dimension line.
-When defining 2D points. the resulting point (not the cursor position) is used for
subsequent dynamic highlighting.
128143 289106 Title: Vitesse - Korean charactor cannot be set to MarPrintOptions.PrinterName
Symptoms: Using the API function MarDrafting.Dwg Print (MarPrintOptions) can
not be performed, if MarPrintOptions.PrinterName contains any Korean
characters.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so mulibyte characters can be used.

Outfitting:

Incident Issue Description


Number Number
12518 52182 Title: Isodraft - When we set the material of the components to DOTU the
isometric is drawn wrongly
Symptoms: When we set the material of the components to DOTU the isometric
is drawn wrongly.
Known workaround: None.
Solution: Detect Gasket at end of dotted series.
48753 79062 Title: Isodraft - Why there is no "RESW" skey?
Symptoms:"RESW" skey not available
Known workaround: None
Solution: Added RE** SKEY.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 160 of 517
Product Release Letter
Incident Issue Description
Number Number
89813 192332 Title: Isodraft - If Bendtable is ON, even set BENDRADI became OFF as well
Symptoms: Bend angle on isometric is suppressed if bend table active
Previous/Known workaround: None
Solution: Do not suppress bend angle on isometric if bend table active.
93106 199320 Title: Cats & Specs - In Paragon, obstruction translucency does not work
Symptoms: Geometry with obstruction set is always appears completely opaque
irrespective of the translucency setting.
Previous/Known workaround: None
Solution: Translucency now works.
126989 287443 Title: Cats & Specs - Paragon - obstrruction translucency settings does not work
128488 290381 Title: Cats & Specs - Autonaming of specification components.
Symptoms: Single specification components added to a specification are not
autonamed.
Previous/Known workaround: Manually rename the components
Solution: Fixed in the specification form.
128213 290429 Title: Isodraft - The component creation form behaves differently depending on
where you try to insert a component.
Symptoms: Some components are flipped in the design resulting in incorrect
flow arrows on piping isometrics.
Previous/Known workaround: Flip the component back.
Solution: The code no longer flips things automatically.
128783 291457 Title: Isodraft - Isodraft crashes when HREF/TREF are Unknown Refs
Symptoms: Isodraft crash
Previous/Known workaround: None
Solution: Allow for unknown HREF/TREF refs when checking for closed loop
spec breaks.
129391 292948 Title: Piping - Area expressions not be used in the component
weight (CWEI) attribute of a component data element (CMPD).
Symptom If CWEI is set to an expression involving NSRF (nett surface area),
evaluating the nett weight in model will crash the program due to an
inifinite recursion.
Previous/Known workaround: None
Solution: Special case code has been added to prevent the recursion.
129558 293485 Title: Isodraft - Incorrect bolt spec shown in material list
Symptoms: Incorrect bolt spec in item code.
Previous/Known workaround: Revert to Fix 41.
Solution: Restore state after closed loop spec break search.
129600 293608 Title: Isodraft - Cuttinglist Word Wrap
Symptoms: Cuttinglist Word Wrap
Previous/Known workaround: None
Solution: If there is no item code on the BOM, then find length of longest pipe
item code and use that.
129398 293956 Title: Isodraft - ISOMETRIC OUTPUT IS NOT SHOWING SKEW
Symptoms: ISOMETRIC OUTPUT IS NOT SHOWING SKEW
Previous/Known workaround: None
Solution: Relax limit when testing for skew.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 161 of 517
Product Release Letter
12.1.SP4.48

Planar Hull:

Incident Issue Description


Number Number
109544 237507 Title: BEVEL_COLOUR_* does not work for CUTOUT in case of Auto Bevel.
Symptoms: See title
Previous/Known workaround: No known workaround exists.
Solution: The bevel colouring not being applied to variable-angle bevels in cut-
out profiles is fixed.
117631 260524 Title: An error occurs when defining the topology point using Profile Cross on
shell profile.
Symptoms: When trying to define a topological point of a shell profile cross
section where the profile is an over CL profile, the system respond with an error
message "The profile does not intersect the given plane."
Previous/Known workaround: No known workaround exists.
Solution: Resolved so the toplological point can be defined.
125145 281354 Title: Functional Description in Hull Design
Symptoms: Adding a number of functional descriptions to the default list shows
only the system defined values.
Previous/Known workaround: Define description intervals with the keyworkd
INTERVAL (see documentation).
Solution: Corrected so all functional descriptions are listed if no Intervals are
defined.
126142 283530 Title: Problem for the bevel side not to apply to the cutout
Symptoms: Giving a bevel to a cutout with negative sign will change to positive
automatically by the system next time the schema is used.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the bevel code will keep the sign for cutout bevel.
126558 284618 Title: The application is forcibly terminate when the boundary of the panel is
modified or newly defined.
Symptoms: When the system allocates approx more than 850 MB memory, the
Boundary Wizard crashes.
Previous/Known workaround: Use schema editor to handle the bondary.
Solution: Abnormal termination in Boundary Wizard avoided for those very large
drawings.
127625 287652 Title: Imperial units: Error message appear wen modifying planar panel
components.
Symptoms: For some components, the Statement Wizard reports "Wrong vlaue"
if using Imperial Units.
Previous/Known workaround: Use Schema Editor instead.
Solution: Fixed the issue so that imperial units can be used in stiffener and
bracket statement wizards.

Hull Production:

Incident Issue Description


Number Number
107580 231567 Title: The bevel information of bracket with excess at the all arms is omitted at
the generic file
Symptoms: If the bracket is symmetric and user defines the excess and bevels
for all arms except for the free arms, the bevel information at the generic file of
port side is omitted. It is ok at the starboard side.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the bevel code will also appear on Port Side Bracket.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 162 of 517
Product Release Letter
Incident Issue Description
Number Number
109433 237172 Title: Enhancement to Add Ppanpart tracing control
Symptoms: When ppanparts aborts, therr is noway to fine out what panel or
component that was the reason for the abortion.
Previous/Known workaround: N/A
Solution: A new keyword to ppanparts.ip is introduced.
TRACE,
By adding this to the file ppanparts.ip information of which panel and which
component oin the panel that is currently handled will be printed in the log file.
THis can then be used in case the program aborts to help find out what may have
gone wrong.
112505 244944 Title: The attachment angle value of a specific location is incorrectly applied.
Symptoms: Attachment angles, marked on curved plates, are not always correct
for attached planar panels and shell profiles.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the attachment angles will be correct for both planar
panels and shell profiles.
120872 269660 Title: Problem for the user defined endcut not to apply to the gen file into the
flange of built-up profile
Symptoms: When the flange of built-up profile will be converted to profile. the
user defined endcut does not apply into the gen file and shape
Previous/Known workaround: No known workaround exists.
Solution: Changed to analyse geometry and presenting end cut type and
parameters. Currently translation can generate end cut types 11, 12, 14, 103, 17,
18, 19, 61 and 62 based on the geometry that is generated from the UDE.
121177 272483 Title: Assembly Selection doesn't work for PPI > Cross Bending Template
Symptoms: There are nothing selected when using Assembly as input for Cross
Bending Templates. Ordinary templates are ok.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so also Assemblies can be used as input for Cross Bending
Templates.
124685 279865 Title: The attachment angles of SB panel displayed on plate parts is strange.
Symptoms: The attachment angles of planar panels on shell plates are not
always correct on SB shell plates.
Previous/Known workaround: No known workaround exits.
Solution: Corrected so the attachment angles on SB plate will be correct.
125576 282219 Title: Enhancement to Add Ppanpart tracing control
Symptoms: When ppanparts aborts, therr is noway to fine out what panel or
component that was the reason for the abortion.
Previous/Known workaround: N/A
Solution: A new keyword to ppanparts.ip is introduced.
TRACE,
By adding this to the file ppanparts.ip information of which panel and which
component on the panel that is currently handled will be printed in the log file.
This can then be used in case the program aborts to help find out what may have
gone wrong.
125631 282373 Title: Position of bend template would be strange.
Symptoms: A five side shell plate with excess on the limits gets strange
positions of the bending templates.
Previous/Known workaround: No known workaround exists.
Solution: The calculation of template positions on plate with excess has been
corrected.
127172 286397 Title: Cannot be extract the all of Pinjig information in only STB'D curved panel.
Symptoms: No jig information can be extracted via Data Extraction for a side
specific curved panel.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the information can be extracted.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 163 of 517
Product Release Letter
Incident Issue Description
Number Number
127440 287241 Title: Problem for the name of the brackets into the knuckled panel to be
identically generated to ATX
Symptoms: Brackets on knuckled panels all get the same name in the ATX file.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the bracket names in the ATX file will be correct for
brackets on Knuckled Panels.

Marine Drafting:

Incident Issue Description


Number Number
104179 223580 Title: Enhancement to add the function allows the user to blank (or un-blank) the
Mat Symbol in Hull View
Symptoms: It is possible to set the material symbol setting to display or hide in
symbolic view by Default File of Planar Hull Modelling. However it is not in our
Display options in Properties menu
Previous/Known workaround: N/A
Solution: An option for displaying stiffener and bracket material symbols is now
available in symbolic view properties.

Pipe Fabrication:

Incident Issue Description


Number Number
112528 245089 Title: 12.1.SP4.42 - PF - Welds for Set-on Tee Is Added to Main
Symptoms: NA
Previous/Known workaround: NA
Solution: Handled the exception by putting a check(i.e. to skip the highlighting
of a branch etc. whose tgeom is false) in case of next element being a set on tee
while highlighting the welds.
113797, 248820, Title: Pipe Fabrication, Modify Spool: in specific case, no limit can be added
121854 272808 Symptoms: NA
Previous/Known workaround: NA
Solution: Noticed that there is no check available in the existing code to check
whether there are any spool breaks present before merging the spools. Included
the check with appropriate conditions and resolved the issue.
Noticed that in process of adding spool limits without welds, if the owner of the
two components picked is not same then the code handles it incase of TEE only.
Resolved it for all other scenarios.
122682 274853 Title: User is prompted by an unnecessary error when having FTUB (e.g. as
fabrication end)
Symptoms: NA
Previous/Known workaround: NA
Solution: Modified the code so that the PTNO of FTUB is given the PTNT of the
previous element and PTNT of FTUB remains 0 if its TGEOM is false.

Outfitting:

Incident Issue Description


Number Number
44033 67485 Title: Draft - 12.1SP2.1 - IsoADP - IsoADP Isometric Production form - Display
Details form does not update.
72802 148683 Title: Draft - CWAY option in list missing when creating Representation Rules in
Outfitting Draft Admin.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 164 of 517
Product Release Letter
Incident Issue Description
Number Number
104571 224464 Title: Design - Error when running Building Applications Concrete Quantities
Symptoms: Running Concrete Quantities on a wall with a sub-component with a
gtype of TUBE that does not have DATA with a dkey of PROF or EPAI, results in
a calculation error.
Previous/Known workaround: Add a DATA element with a dkey of PROF or
EPAI to the catalogue sub-component
Solution: A default value of 1mm is applied if DATA with a dkey of PROF or
EPAI cannot be found. This default value existed before but did not have units
(mm) and so caused a calculation error.
106453 228860 Title: ISODRAFT: the Overall dimension is strange.
Symptoms: Overall dimensioning is incorrect for a fitting which has 'plain' end
connections.
Previous/Known workaround: None
Solution: If fitting has 'plain' end connections, correct dimensioning.
114011 249502 Title: Idodraft - PSKEY causes incorrect orientation for user-defined SKEY.
Symptoms: PSKEY causes incorrect orientation for user-defined SKEY.
Previous/Known workaround: None
Solution: Check for 'FLSC' when checking for flange orientation.
120246 267980 Title: Isodraft - Wrong direction shown for mitred bend isometric
Symptoms: Direction inverted after mitred bend.
Previous/Known workaround: None.
Solution: Ignore zero-length tube direction.
125044 281446 Title: Isodraft - Wrong coordinates type on ISODRAFT
Symptoms: Wrong coordinates type on ISODRAFT - should be SHIP.
Previous/Known workaround: None
Solution: Accommodate Ship Reference Coordinates within Isodraw.
125487 282009 Title: Total Length of Pipe
Symptoms: User wishes to specify that imperial Pipe Lengths on BOM are to be
shown in decimal feet.
Previous/Known workaround: None
Solution: Allow User to specify that imperial Pipe Lengths on BOM to be shown
in decimal feet.
126633 284986 Title: Design - SP4.46_'OutOfRangeException' on Fabrication Check form
Symptoms: NA
Previous/Known workaround: NA
Solution: Handled the exception in the code which arises when only one
component exists in the branch/if it is the first component. resolved the issue.
Also checked few other scenarios related to spool breaks.
127048 286079 Title: Isodraft - Non-existing tube displayed on the isometric
Symptoms: Non-existing tube displayed on the isometric
Previous/Known workaround: None
Solution: If Flange start + weld only do not insert tubeoutput.
127450 287358 Title: Isodraft, problems with field welds
Symptoms: Problems with dimensioning at FIELD welds
Previous/Known workaround: None
Solution: Always dimension at a field weld which sits between a SHOP
component and a FIELD component.
127518 287480 Title: Isodraft - Incorrect and Inconsistent reprting of Cut Pipe lengths
Symptoms: Incorrect and Inconsistent reprting of Cut Pipe lengths
Previous/Known workaround: Use set-on tees correctly.
Solution: Detect rogue tees with zero length.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 165 of 517
Product Release Letter
Incident Issue Description
Number Number
127596 287641 Title: The ISO Drawing does not generated properly #iso symbol error
Symptoms: Two tapped tees overlap.
Previous/Known workaround: Ensure two tapped tees do not point to the
same segment of a PCOM
Solution: Detect if two tapped tees point to the same outer segment of a PCOM.
If so, if there is a midpoint tee point available, point the tee which is nearer to the
midpoint to that tee point.

12.1.SP4.47

Initial Design:

Incident Issue Description


Number Number
41046 66211 Title: Importing compartment from XML do not assign content category
Symptoms: Even if category is assigned to compartment in XML file, category is
not set to compartment after XML import.
Previous/Known workaround: Assign category manually after import
Solution: Code change applied to correct error.
86002 183908 Title: export loadstar data
Symptoms: File → Export → LoadStar Data option doesn’t work
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the export function will procude the file.
92911 199025 Title: Initial Design Surface & Compartment creates too many files
Symptoms: When opening Surface (.dm) file in Surface & Compartment
application , system creates ACISJour_0.scm and ACISJour_0_0.sat files each
time when the application is opened for the .dm file. Then there are too many files
in the initial design project folder.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the files are no longer created.

Planar Hull:

Incident Issue Description


Number Number
85108 181389 Title: The weld syntax in Weld Statement is wrong when the weld is asymmetric
Symptoms: It is not possible to define an assymetric weld in the Weld statement
where the "other side" is set to zero.
Previous/Known workaround: No known workaround exists.
Solution: Both the schema and the StatementWizard will now handle that the
weld size on "other side" is set to zero.
107636 231556 Title: Boundary Wizard - Offset from Surface – 3 Point Plane
Symptoms: When making a boundary with COR for a panel defined in a three
point plane, the SID has no affect.
Previous/Known workaround: Use the sign +/- do get the correct offset side.
Solution: Problem with COR and SID on inclined panels solved. If SID is given it
always determine the offset direction regrdless of the sign of COR. If no SID
given, the sign decides the offset direction.
118883 264737 Title: Flange on a view error
Symptoms: After changing a view location by coordinates or view detph an
adjoined panel folded flange has a wrong image.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the image of the folded flange is
correct.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 166 of 517
Product Release Letter
Incident Issue Description
Number Number
119478 266244 Title: Hook definitions in holes not working properly
Symptoms: When trying to extend the number of hooks, the system sets an error
and the hole is not updated.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the total of 10 values can be handled for hole hooks.

Curved Hull:

Incident Issue Description


Number Number
92842 198887 Title: Wvolume of CPANEL is calculated incorrectly.
Symptoms: See title
Previous/Known workaround: No known workaround exists.
Solution: The WVOLUME attribute for CPANEL elements was transformed
incorrectly. This has now been addressed.
97623 209413 Title: Wvolume of CPANEL is calculated incorrectly.
Symptoms: See title
Previous/Known workaround: No known workaround exists.
Solution: The WVOLUME attribute for CPANEL elements was transformed
incorrectly. This has now been addressed.
112449 244843 Title: CHM Problems with completeness of ShellX view over CL
Symptoms: A ShellX view over CL shows problems with completeness of model
presentation when it is limited by Z-coordinates.
Previous/Known workaround: No known workaround exists
Solution: The problem has been solved so that a ShellX view over CL works as it
should when limited by a Z coordinate.
118784 264529 Title: Colour of symbols changes automatically
Symptoms: After making (or recreting) a Plate Development View, the model
colour and linetypes are reset.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so Plate Development View will not reset model colour and
linetype.
124865 280483 Title: Holes in Shell Expansion
Symptoms: Currently It is possible to show the holes only if the name of those
curved panel which has holes are included in the Panel Tab (Auto selection
should be deselected). But in this case, the plane panels are lost.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so the holes in Curved panels are
included.

Hull Structural Design:

Incident Issue Description


Number Number
27146, 68899, Title: Two or more functional descriptions of Shellstiffener cannot be changed.
125961 283106 Symptoms: It is not possible to change Functional Description on multiple
selected Shell Stiffeners.
Previous/Known workaround: Modify Functional Description one by one.
Solution: The problem has been solved so that it is possible to
change functional description for several shell stiffeners.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 167 of 517
Product Release Letter
Incident Issue Description
Number Number
125570 190813, Title: An fatal error occur when run the Idealise Model if added the same panel
282209 twice in the same block.
Symptoms: Trying to idealize an already existing panel into the same idelized
block will make the system to abort.
Previous/Known workaround: Remove the idealized panel before new
idelization begins.
Solution: It is now possible to idealize a panel that is already in the idealized
block.
124318 279065 Title: Profile references of Bracket syntax 2 not updated after BLOCK splitting
Symptoms: See title
Previous/Known workaround: No known workaround exists.
Solution: Bracket now refers the correct panel after panel split and block divide.

Hull Production:

Incident Issue Description


Number Number
94975 202967 Title: Reverse straignt line of defined shrinkage is outputted incorrectly.
Symptoms: The Inverse Bending Curve for Shell Profiles may get distorted in
case Shrinkage is used for the profile.
Previous/Known workaround: No known workaround exists.
Note, there is no problem if no shrinkage is used.
Solution: Curve is corrected so it is corret when shrinkage is defined.
266174 Title: Wrong GSD marks generated for hole in flange
Symptoms: If user performs PPI for a plane panel which has flange in hole valid
only for PS, the drawings gives the markings for GSD even on SB panel
Previous/Known workaround: N/A
Solution: Corrected so the GSD is only created for valid flanges.
119665 266827 Title: Issue of stiffeners in bracket
Symptoms: If there are several bracket with stiffeners in one panel, and this FB
stiffeners are split to PLDB, there will be some error in stiffeners.
One stiffener will has several ParRef, and the others stiffeners have no ParRef.
Previous/Known workaround: No known workaround exists
Solution: HBRSTI, which are meeting criteria in SBH_PROF_TO_PLDB, will get
correct ParRef attribute after PPanParts has been executed.
278644 Title: Nested On Information for stiffeners & Flanges are not getting populated in
WCOG Report
Symptoms: Information is missing for stiffener flatbars.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that nested on in WCOG list is reported for profiles.
124564 279700 Title: Symmetrical shell stiffener in unsymetrical blocks
Symptoms: Using symmetrical defined shell stiffeners in side specific Curved
Panels that ar estored in different blocks (one for PS and one for SB) gives the
wrong part name in profile sketches and lists when block name is included in the
name.
Previous/Known workaround: No kn own workaround exists.
Solution: Corrected so the shell stiffener will get correct block name.
124683 279864 Title: The attachment angles of shell longi.profile displayed on plate parts is
strange.
Symptoms: A shell profile that crosses over two shell plates gets different
attachment angle marked on the different plates.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so attachment angle marking is the same in both plates that
the profile crosses.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 168 of 517
Product Release Letter
Incident Issue Description
Number Number
282962 Title: Profile Nesting wrong with profiles with Excess, robot cuts wrong profiles
Symptoms: When using SBH_PROF_EXC_AS_SHRINK, excess is added both
to mould and total length.
Previous/Known workaround: No known workaround exists.
Solution: Problem relates to usage of SBH_PROF_EXC_AS_SHRINK. In this
case excess is added BOTH to mould and total length, meaning that excess shall
not be handled once this is done. Code is now corrected.
126657 285045 Title: Problem for the stiffener to be defined by end not to generate the endcut's
bevel at generic file
Symptoms: When Automatic Bevel is active and a bevel code is given to a
stiffener end, the bevel is not properly handled and sometimes missing in generic
file.
Previous/Known workaround: When a bevel is given for the end e.g. for the
web, make sure also NABW is given at the same time (NABF for flange part).
Solution: Corrected so the bevel at stiffener ends will be properly handled when
autobevel is active and an actual bevel code has been given.
126193 285193 Title: Problem not to generate the bevel data of the clip with negative bevel
Symptoms: Giving a bevel to a user defined clip (collar plate) for the keyword
BCS works only if the bevel code is positive. A negative bevel code will not be
transfered to hte resulting plate part.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the bevel will remain also when defined as negative.

Marine Drafting:

Incident Issue Description


Number Number
109844 238225 Title: No collection for ev. points(label) for HVAC due style representation
Symptoms: Event points (label) cannot be collected for rectangular duct.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the event points can be collected.
123481 276683 Title: After setting Bpoffset of glab to 'default' and drawing is saved Marine
drafting is down
Symptoms: See title
Previous/Known workaround: No known workaround exists
Solution: Corrected so system will not abort when Bpoffset of glab is defined.
123647 277247 Title: If I insert parallel curve then system error.
Symptoms: When trying to make a parallel curve, the system gives an error
Previous/Known workaround: No known workaround exists.
Solution: The error sometimes occured when distance was equal to the radius of
an arc segment, due to numerical problems. This problem is solved.
123786 277772 Title: Regi name with underscore and digits in the Draft Explorer
Symptoms: It's immpossible to save user defined type drawing in REGI if this
REGI name has underscore and following digits. For example REGI Room_3103.
If you try to save a new drawing a new REGI creates with duplicating underscore
and following digits. For example REGI Room_3103_3103.
Previous/Known workaround: Avoid underscore in the REGI name
Solution: Solved so it is possible to use underscore in the REGI name.
123902, 277988, Title: CWBRAN disappears if head is not in the 2d view
52645, 86939, Symptoms: If the CWBRAN RPATH head is outside the 2d view boundary, or
63455, 116341, sectioned out of the view, the whole CWBRAN disappears (although the dressed
81381, 173296, cableway if any will remain OK)
83645, 178052, Previous/Known workaround: none
81560, 188423, Solution: CWBRANs where the head is sectioned out of the view, or outside the
92336, 198180, view boundary, are now still drawn like other design elements.
101991 219214

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 169 of 517
Product Release Letter
Incident Issue Description
Number Number
124378 279213 Title: Profile Mounting Angle is wrong
Symptoms: Using the function "Shell Profile Mounting Angle" and making a
measurement on SB side, the result is not correct. No problem on PS side.
Previous/Known workaround: Add manually a tangent line at the footpoint of
the shell profile and measure with help of this line.
Solution: Corrected so measure on SB side will show the mounting angle.

Outfitting:

Incident Issue Description


Number Number
75060 156428 Title: Isodraft - ATTA's position in branch hierarchy causes incorrect branch
dimension in ISODRAFT.
Symptoms: ATTA's position in branch hierarchy causes incorrect branch
dimension in ISODRAFT.
Known workaround: None
Solution: Allow for ATTA if it is at same point as zero-length bend.
123434 277457 Title: Design - Useless message when Modify > Spool (Pipe Fabrication)
Symptoms: NA
Previous/Known workaround: NA
Solution: Removed the alert message and resolved the issue.
124451 279417 Title: Isodraft - OL:ET in isometric showing as BW and should be Flanged
Symptoms: OL:ET in isometric showing as BW and should be Flanged
Previous/Known workaround: None
Solution: If end connection is 'flanged' then insert flange.
125111 281062 Title: Isodraft - Isodraft Dimensioning issue with centerline option
Symptoms: Incorrect support dimension when options 'Support Dimensions only
with Centerline Overall' are selected.
Previous/Known workaround: None
Solution: Handle flanges correctly when options 'Support Dimensions only with
Centerline Overall' are selected.
126367 284277 Title: Structures - GTROOM does not return room for SBFI/PFIT elements under
a FLOOR
126661 284909 Title: Design - Component Creation form (2,25) Read only DB error
Symptoms: (2,25) Read only DB
Previous/Known workaround: None
Solution: Add an error handler for when ATTABREAK returns (2,25) Read only
DB.

12.1.SP4.46

marAPI:

Incident Issue Description


Number Number
118443 263363 Title: Cannot add more than 12 panel in MarSymbolicView.SetPanelsFilter()
Symptoms: See title
Previous/Known workaround: No known workaround exists.
Solution: There was an error introduced in 12.1.SP4 Fix 43. This has now been
fixed. It is again possible to add more than 12 panels to the filter when creating a
symbolic view using marAPI.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 170 of 517
Product Release Letter
Planar Hull:

Incident Issue Description


Number Number
75290 154992 Title: Enhancement to Hull text projection can be run along the surface via Hull
Mark. For more information refer to section Enhancements above.
88082 188569 Title: Creation a curve along a profile
Symptoms: Create a curve along a profile does not work through the wizard.
Previous/Known workaround: Make the statement manually in the schema
editor.
Solution: The Curve Wizard is now changed so tht you can use an external
profile as reference when creating a fillet curve.
93954 200709 Title: Corrections for Hullmarks
Symptoms: When Hullmakrs, produced as plates, are checked, the shape is not
correct.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the resulting shape will be ok.
90854 208970 Title: Consideration to chamfer in bounding panels is not properly taken for X or
Y bevel
Symptoms: When using SBH_WIDE_CHAMFER, the abutting panel boundary
does not get correct chamfer.
Previous/Known workaround: No known workaround exists.
Solution: Correction is done to get the chamfer geometry for wide chamfer
handling.
104897 225153 Title: Problem with NOENDCUTSYMB parameter
Symptoms: when in Structural Design and changing the variable
NOENDCUTSYMB to <NOT SET> and saving the defaults, this parameter is not
written in the default file and next time Structural Design is started, user has to
manually change this again.
Previous/Known workaround: Add NOENDCUTSYMB = <NOT SET> in the
default file sj700.sbd.
Solution: The default behavior for Structural Design is to not use end cut
symbols.
A change is made so if the value for NOENDCUTSYMB is set to <NOT SET>,
this will also be written to the default file when saved.
109883 238242 Title: GUI form issue - Unwanted color assignment
Symptoms: Brackets/Clips: When a user creates a bracket, the "color" field is
blanked. Bracket creation results in the default color being applied correctly from
the SVIEW object. When the user selects another bracket syntax, the Color field
is re-populated with "GREEN".
Previous/Known workaround: Manually change the colour field.
Solution: Corrected so that pressing any clear button for brackets and clips or
changing syntax for brackets will leave the colour field blank.
119271 265876 Title: GPS2 not empty on PDMS Attribute level
Symptoms: In e.g. flange statement GPS2 is made empty, but when use q var
!!ce.gpstr[2] there come string that is not empty.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the right GPS string will be returned.
120870 269824 Title: Panel copy issue
Symptoms: Sometimes when copying a planar panel, statements gets lost.
Previous/Known workaround: No known workaround exists.
Solution: When the boundary goes wrong in copying a panel the rest of the
components are copied without generation. However, if a Marking definition
creates problems, the process is interupted. This is now corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 171 of 517
Product Release Letter
Incident Issue Description
Number Number
120974 269972 Title: The shape of SB-curved stiffener is displayed incorrectly in 3D-view.
Symptoms: If create by curved stiffener on the symmetric model (P & S),
the shape of SB-curved stiffener is displayed incorrectly in 3D-view/Shaded
viewport. However, there are no problem with Profile sketch and Symbolic
View/Insert model.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the SB-curved stiffener is
displayed correctly in 3D-view.
121500 271685 Title: Double bulb settings
Symptoms: Enhancement to control angle in a double bulb profile.
Previous/Known workaround: N/A
Solution: A new environment variable, SBH_DOUBLE_BULB_ANGLE, has been
introduced.
This will control the angle of the lowar part of the flange in a double bulb profile.
It will not affect other double bulb profiles such as Fundia.
122663 274843 Title: Even if define the SB-side model, panel is displayed on the PS-side.
Symptoms: Modeling a Planar Panel at Y=-1 (to -12.5, only SB) will be displayed
at PS.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the panel is displayed on the
correct side.
Panels generated at this location may have to be regenerated in order to be
displayed at the correct side. This affects drawing only.
123555 276871 Title: The symbol of material side is disappeared from sectional view of swage
panel
Symptoms: When making a section view where there is a swage panel included,
not intersecting the drawing plane, there is no material symbol indicating the
material sade of the panel.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so swage panels will get material symbol.
124217 278831 Title: Application exit to indicate the wrong objects at the boundary statement
wizard
Symptoms: When user tryes to indicate a curve for a boundary but indicates
wrongly, the program aborts.
Previous/Known workaround: Make sure a proper curve is indicated.
Solution: Corrected so the program will not exit when the user indicates wrongly.

Curved Hull:

Incident Issue Description


Number Number
90387 193771 Title: Star board dummy profiles are projected on PS
Symptoms: In a project where Free Naming is in use, projection of dummy
profiles made on SB side is projected on PS. If the dummy profile is switched
back to true profile, error 1049 is signaled.
Previous/Known workaround: No known workaround exits.
Solution: The problem of reflection and 1049 has been solved. However the
stiffener has to be recreated after change to see the visual changes!
90752 194657 Title: Cplate disappears from model view if it is removed from Curved Panel
Symptoms: When a Cplate is removed from a Cpanel it also disappears from
other model view. The user needs to add the Cplate using "Insert Model".
Previous/Known workaround: Manually add the CPlate where it was removed
by the system.
Solution: The problem have been solved so that plates are only removed in the
curved panel view.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 172 of 517
Product Release Letter
Incident Issue Description
Number Number
113529 248095 Title: Cplate disappears from model view if it is removed from Curved Panel
Symptoms: When a Cplate is removed from a Cpanel it also disappears from
other model view. The user needs to add the Cplate using "Insert Model".
Previous/Known workaround: Manually add the CPlate where it was removed
by the system.
Solution: The problem have been solved so that plates are only removed in the
curved panel view.
114534 251105 Title: XML Batch generation of Curved Hull panels - error messages
Symptoms: A curved panel containing shell plates and shell stiffeners is created
from XML file. The job log file contains error messages:

Model object XXXXX not found on the data bank!


Data bank not connected!
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the xml import
is completed without incorrect error messages. That could
happen for SB specific plates.
269205 Title: Bevel side changed for one hole in curved panel changes the bevel side for
all the holes.
Symptoms: When changing the bevel side for holes in a Curved Panel, it is
eventually always reset to FOR.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so it is now possible to toggle between the holes and the
bevel side will remain as selected.
121510 271367 Title: Problem for shell stiffenre not to add the marking to be welded against any
of the plate part
Symptoms: If the curved panels just are created by shell stiffener. the marking is
not generated for all profiles that are welded against any of the surfaces of the
plate part.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that markings will be created after that Curved Panel
Parts Generation has been re-run on the curved panel without plate parts.
122435 274404 Title: Impossible to modify/delete transversal curved profiles
Symptoms: When selecting Shell Profiles, transversals are not recognized by
the system.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so also transversals can be selected in the same way as
longitudinals.
122481 274427 Title: marked hole in curved panel
Symptoms: Marked holes in Curved Panels is drawn as Burnt Holes.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the hole is drawn as marked in
the panel. The plate with the hole has to be recreated if it had a hole in it before
due to this issue.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 173 of 517
Product Release Letter
Hull Structural Design:

Incident Issue Description


Number Number
104897 225153 Title: Problem with NOENDCUTSYMB parameter
Symptoms: when in Structural Design and changing the variable
NOENDCUTSYMB to <NOT SET> and saving the defaults, this parameter is not
written in the default file and next time Structural Design is started, user has to
manually change this again.
Previous/Known workaround: Add NOENDCUTSYMB = <NOT SET> in the
default file sj700.sbd.
Solution: The default behavior for Structural Design is to not use end cut
symbols.
A change is made so if the value for NOENDCUTSYMB is set to <NOT SET>,
this will also be written to the default file when saved.
121964 272905 Title: Problem with NOENDCUTSYMB parameter
Symptoms: when in Structural Design and changing the variable
NOENDCUTSYMB to <NOT SET> and saving the defaults, this parameter is not
written in the default file and next time Structural Design is started, user has to
manually change this again.
Previous/Known workaround: Add NOENDCUTSYMB = <NOT SET> in the
default file sj700.sbd.
Solution: The default behavior for Structural Design is to not use end cut
symbols.
A change is made so if the value for NOENDCUTSYMB is set to <NOT SET>,
this will also be written to the default file when saved.
122419 274213 Title: The shape of SB-curved stiffener is displayed incorrectly in 3D-view.
Symptoms: If create by curved stiffener on the symmetric model (P & S),
the shape of SB-curved stiffener is displayed incorrectly in 3D-view/Shaded
viewport.
However, there are no problem with Profile sketch and Symbolic View/Insert
model.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solve so that the SB-curved stiffener is
displayed correctly in 3D-view.

Hull Production:

Incident Issue Description


Number Number
90617 194340 Title: Plate parts from Structures (FRMW)
Symptoms: Normal user has not the right to create top Level elements.
Therefore OSP is only working when beeing a free user or when OPTBLO is set
in Framework. But no real Panel are wanted so only Pdname is set, but then
ppanparts crashes.
Previous/Known workaround: Either set OPTBLO in the FRMW or have write
access on top level in the deign db.
Solution: With this fix outfitting models can be processed by PPanParts without
the user has permissions to create block.
111502 242608 Title: The HULL MARK of SB-side is not expanded in SBP panel.
Symptoms: A Hull Mark that is defined on SB side is not marked on the SB part
of a symmetrical panel.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so Hull Marks on SB side will be projected to the plate.
Ppanparts must be rerun for already handled parts.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 174 of 517
Product Release Letter
Incident Issue Description
Number Number
112155 244135 Title: The Width of Clip is incorrect in Plate part.
Symptoms: When defining a cutout with a clip, where the clip is set with an offset
to be in line with the plate material and also using automatic varying bevel, the
size of the resulting clip part is not correct.
Previous/Known workaround: Specify the vbevel intervalls with fixed bevel
codes.
Solution: Corrected so clip size will be correct also when varying bevel is used
for clips defined with an offset.
Panels with these clips must be resplit to get the correct size.
117637 260150 Title: Excess for shell plates not included in material ordering of plates (PPI HUll)
Symptoms: See title.
Previous/Known workaround: No known workaround exists.
Solution: Corrected, So if the shell plate has 4 limits it will assign the excess
value either to LE or BR.
The reason that limits other than 4 is not implemented is the ambigiuty of length
and breadth information to represent.
119393 267027 Title: MCONTOUR and NCONTOUR have different NO_OF_SEG in generic file.
Symptoms: In the generic file there is a segment of zero length.
Previous/Known workaround: Manually remove the zero seg,emt from the
generic file.
Solution: Redundant very short segments will now be removed from the trace
contour and from the neutral line contour. This means that the number of
segments for the MCONTOUR and the NCONTOUR in the generic file will be
equal.
120237 268623 Title: After Profile Sketch and List, in case of OVER/CL panel the end of profile is
reversed.
Symptoms: See title
Previous/Known workaround: No known workaround exists.
Solution: Planar panel parts generation corrected so that the direction of flange
curves on starboard on over centre-line panels will be correct.
121498 271321 Title: Cpanparts crashes with SB plate with many holes and bending templates
Symptoms: Making a Curved Panel with many holes and then add bending
templates, will make the marking (cppanparts) to abort.
Previous/Known workaround: No known workaround exists.
Solution: An internal error was set and not handled correctly.
This is not handled correctly. It does not affect the end result.
271863 Title: Corrections for Hullmarks
Symptoms: When Hullmarks, produced as plates, are checked, the shape is not
correct.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the resulting shape will be ok.
272354 Title: The shape of HullCurve is strange with Jig Pillars.
Symptoms: A knuckled curve is not presented correctly in the Jig pillar receipt
drawing.
Previous/Known workaround: No known workaround exists.
Solution: A method has been added to detect knuckles in curves and see to that
the curve is divided in that point to get good result.
121871 272760 Title: matlist of bars with errors
Symptoms: When running Material Ordering of Bars, the endcut 2 is not correct
in the resulting list. It is always the same as endcut 1.
Previous/Known workaround: No known workaround exists.
Solution: Endcut 1 was written for both ends. This is now corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 175 of 517
Product Release Letter
Incident Issue Description
Number Number
122020 273109 Title: Fatal Error while execute ppanparts for the panel with tap at seam and limit
Symptoms: Fatal error occured while executing the ppanparts for the panel with
tap pieces to be defined at intersection between seam and limit
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the parts will be created including the tap.
124213 278824 Title: Problem for the bevel type 41 to change the depth on this side and other
side
Symptoms: Variant 4 of bevel type 4 gives wrong values for depth_ts and
depth_os. Depth_ts should have the values of depth_os and vice verca.
Previous/Known workaround: No known workaround exists.
Solution: Correctd for bevel type 41, variant 4 so the depth on both sides are
correct.

Hull Nesting:

Incident Issue Description


Number Number
121329 271034 Title: Incorrect option to open drawing in nesting mode results in empty drawing
Symptoms: Despite having a nested plate open, it is possible to open a drawing.
The File - Open menu is correct disabled, but you can open a drawing from the
'Most recently used drawings' drop down menu.
Previous/Known workaround: No known workaround exists.
Solution: The "Most recently used drawings" drop down menu" will be disabled
when "File/Open" button is.
121699 272562 Title: Fatal Error after Labelling Production Information text
Symptoms: By having an empty value for the nesting default
BURN_NO_BEVEL_TEXT makes the system to abort when a bevel is set as a
lable.
Previous/Known workaround: Make sure there are text in the default
BURN_NO_BEVEL_TEXT. Place the text and later on remove the labeld text.
Solution: Corrected so the BURN_NO_BEVEL_TEXT can be used with an
empty value.If empty, function will continue with the next bevel interval.

Hull Weld Planning:

Incident Issue Description


Number Number
110046 238685 Title: Swedge and detect welds
Symptoms: In some cases, application crashes when trying to detect welds
between swage panels. In both ways to detect welds, interactive and in batch.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so weld are detected when swage panels are involved.

Marine Drafting:

Incident Issue Description


Number Number
104422 224058 Title: Holes in swage panel
Symptoms: When making a section view of a planar panel containing swage and
holes, the system aborts.
Previous/Known workaround: No known workaround exists.
Solution: Corrected, so the system will not abort when making the section view.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 176 of 517
Product Release Letter
Incident Issue Description
Number Number
118932 264633 Title: After replace the existing view with name, the name info. is different on
drawing view.
Symptoms: After replace the existing view with name e.g. "FR.1 SEC.", but It is
displayed "VIEW#1" on drawing view.
Previous/Known workaround: No known workaround exists.
Solution: Fixed so correct name is displayed.
120765 269349 Title: Blanking of labels does not work for 12.1.SP4.fix43
Symptoms: Label blanking in Marine Drafting or Hull Design does not work if
label frame (Lframe) is not used.
Previous/Known workaround: No known workaround exists.
Solution: Corrected.
120944 269915 Title: The shape of flange endcut is strange with degree 90 over in Insert/3D
view.
Symptoms: Using endcut type 14 where a1 parameter is set to more than 90
degrees is not correctly presented in 3D views.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the endcut looks OK for over 90
degrees angle.
121047 270206 Title: VSEC information for Slice is lost after SDB Export & Import
Symptoms: See title
Previous/Known workaround: No known workaround exists.
Solution: Problem solved.
When importing SDB drawings, the view slice information is now persisted in
PADD drawing (VSEC and PPLA elements are created).
121481 271191 Title: Selected models for Model Copy are highlighted in all views, which makes
low performance.
Symptoms: When many views are present in the drawing, the highlighting of
selected models will slow down the system.
Previous/Known workaround: Keep the number of views to a small number (<
50).
Solution: Performance problems during highlighting of models solved.
122121 273490 Title: An fatal error occur when using Slice.
Symptoms: Fatal error occurs when using Slice on curved panel, (SBP). There is
no problem if view have only port panel.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so no fatal error will happen when using slice on Curved
Panels.
122128 274129 Title: Usage of Drawing References crashes drawings
Symptoms: Opening a drawing as "Read Only" when the drawing containd
drawing references will crash the system.
Previous/Known workaround: A work-around is to avoid opening drawings as
read-only if they contains drawing references.
If You still open such a drawing as read-only, to get things in sync, just close the
drawing, open the referred drawing and then close it again.
Solution: Corrected so the drawings can be safely opened.
275172 Title: Initial state of a Multo View project in Marine Dtafting
Symptoms: When Marine Drafting is started up, there is no way to control the
mode in case the project is a multi view project.
Previous/Known workaround: No known workaround exists.
Solution: We have now implemented a new drafting default keyword to control
the initial view mode in Marine Drafting (and also E3D Draw).The keyword will
only have effect for multi-view projects:
INITIAL_MULTIVIEW_PROJECT_MODE
Possible values are "AUTO", "PRODUCTION" or "DESIGN".

A single view project is not affected as only Production view exists.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 177 of 517
Product Release Letter
Incident Issue Description
Number Number
123902 277988 Title: CWBRAN disappears if head is not in the 2d view
Symptoms: If the CWBRAN RPATH head is outside the 2d view boundary, or
sectioned out of the view, the whole CWBRAN disappears (although the dressed
cableway if any will remain OK)
Previous/Known workaround: None
Solution: CWBRANs where the head is sectioned out of the view, or outside the
view boundary, are now still drawn like other design elements.

Pipe Fabrication:

Incident Issue Description


Number Number
104789 225659 Title: How is calculated VSCALE for a VIEW (Pipe Fabrication)?
Symptoms: NA
Previous/Known workaround: NA
Solution: Observed that if the function attribute of the sheet is unset then the
issue arises. Resolved it.
111823 243470 Title: Inconsistent spool limit between Pipe Fabrication in Spooler
Symptoms: See title.
Previous/Known workaround: No known workaround.
Solution: Problem arises because the ASFBREAK is not being set for the
second component while adding a spool limit. Also, by doing this setting there is
an effect of a dummy spool getting added in PSLIST. Fixed the issue.
113797 248820 Title: Pipe Fabrication, Modify Spool: in specific case, no limit can be added
Symptoms: See title.
Previous/Known workaround: No known workaround.
Solution: Noticed that in process of adding spool limits without welds, if the
owner of the two components picked is not same then the code handles it incase
of TEE only. Resolved it for all other scenarios.
119316, 266170, Title: Pipe Fabrication Assembly Table Two Elbow Rotate Value error
123408 276478 Symptoms: NA
Previous/Known workaround: NA
Solution: Modified the code for the calculation of TURN value and resolved the
issue.
121119 271209 Title: PF issues with master view in Marine Drafting
Symptoms: NA
Previous/Known workaround: NA
Solution: Noticed issues with master view formation when PTAP is included in
the spool and resolved it. Also, issues exist while calculating ADEG for second
view and fixed it.
122682 274853 Title: User is prompted by an unnecessary error when having FTUB (e.g. as
fabrication end)
Symptoms: NA
Previous/Known workaround: NA
Solution: An error saying there is no PTNH attribute is popping up when there is
an FTUB attached in the branch. Resolved it.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 178 of 517
Product Release Letter
Outfitting:

Incident Issue Description


Number Number
66722 127110 Title: Piping - In certain configuration, it's not possible to connect branches
Symptoms: NA
Known workaround: NA
Solution: The issue was because the wrong selection of Head and tail
parameters. This has been rectified now in the code.
72250 147141 Title: Slope lines
Symptoms: Reference label to MTO disappears for ELBO if zero radius bend is
used to fix the angle for sloping pipe.
Known workaround: None
Solution: If pipe following flange - check for zero bend.
77720 162388 Title: Isodraft - We set Dimension Labels to "Above", but Label was produced for
below
Symptoms: When "Dimension Labels" set to "Above", labels are produced
below the dimension line,
Previous/Known workaround: None
Solution: Always put label above the dimension line not below.
88551 189521 Title: Piping - Inacurrate QPR Bend Radius Choice Form & Message
Symptoms: Reference term inacurrately represented as 'bending machine'
Previous/Known workaround: None
Solution: Renamed 'bending machine' to 'reference' in all the occurences.
94583 202121 Title: Spooler - Spooler ignores Network Searching Search within setting when
adding items to a Spool Drawing
Symptoms: Items from different Pipes added to a Spool Drawing when Search
within set to PIPE (for example)
Previous/Known workaround: None
Solution: Check the Network Searching Search within setting when
adding items to a Spool Drawing.
93672 203298 Title: Spooler - Reference Dimension points at P0 of Tee for Branch isometric.
Symptoms: Reference Dimension points at P0 of Tee instead of PL.
Previous/Known workaround: None.
Solution: The code now ensures weld precedes any reference dimension.
106194 229075 Title: USER DEFINED SYMBOL FLIPS WHEN GENERATE ISO ON PIPE
LEVEL
Symptoms: USER DEFINED SYMBOL FLIPS WHEN GENERATE ISO ON PIPE
LEVEL
Previous/Known workaround: None
Solution: When checking for 'flow dependency', the code now checks the base
SKEY.
110253 239458 Title: HVAC - Crash searching for MESH
Symptoms: Crash if DESP[] added to search column
Previous/Known workaround: Avoid adding DESP[] containing WORDs
Solution: Check for WORD parameters.
113010 247142 Title: Isodraft - We set Dimension Labels to "Above", but Label was produced for
below
Symptoms: When "Dimension Labels" set to "Above", labels are produced
below the dimension line,
Previous/Known workaround: None
Solution: Always put label above the dimension line not below.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 179 of 517
Product Release Letter
Incident Issue Description
Number Number
115118 253322 Title: Piping - NSBC unexpected result when adding a boss connection
Symptoms: connecting an NSBC branch and then selecting a boss connection
results in the connected end switching to the other side of the main and swapping
the head and tail.
Known workaround: Add a boss manually.
Solution: This was cause by a previous small fix which has now been removed.
115564 254494 Title: Isodraft - Flanged side wrong showed on isometric symbol for PCOM
Tundish (Funnel) TUFL
Symptoms: Flanged side wrong showed on isometric symbol for PCOM Tundish
(Funnel) TUFL
Previous/Known workaround: None
Solution: Code now adds in "slip on" flange before TUFL if TUFL is reversed or
after TUFL if not.
117574 259872 Title: Isodraft - Missing connection weld
Symptoms: Missing weld
Previous/Known workaround: None
Solution: Show connection weld.
122185 273678 Title: Spooler - Error when adding item to a spool drawing after undoing the
addition of an ATTA in component creation form
Symptoms: Spooler (83:499) - Error message
Previous/Known workaround: Delete and recreate Pipe
Solution: Set ATTABREAK ON when undoing the ATTA addition.
123714 277439 Title: Crash searching for MESH
Symptoms: Crash if DESP[] added to search column.
Previous/Known workaround: Avoid adding DESP[] containing WORDs.
Solution: Check for WORD parameters.

12.1.SP4.45

Planar Hull:

Incident Issue Description


Number Number
94968 203577 Title: MarPanelSchema.GetStatementAsValues crahes
Symptoms: The methode GetStatementAsValues in MarPanelSchema does not
work as it crashes the script.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so MarPanelSchema.GetStatementAsValues(group) is now
working as expected.
118291 262911 Title: Please keep check Autobevel for Bracket.
Symptoms: For stiffeners, the check box for auto bevel is always checked when
entering the form in the wizard. This is not the case for brackets where the user
must control this check box each time.
Previous/Known workaround: No known workaround exists.
Solution: Wizard changed so when auto bevel is requested for brackets, the tick
box is always ticked when entering the form. Same behaviour as for stiffeners.
119416 265980 Title: Setting CASE=1 for stiffeners crashes Hull Design
Symptoms: See Title
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that there is no crash when CASE is
set.
120913, 269838, Title: POSNO not allong stiffeners anymore.
122144 273680 Symptoms: Adding a stiffener position number without any reference lines will
place the position number note in strange directions and not along the stiffener.
Previous/Known workaround: Make a small reference line along the stiffener.
Solution: Corrected so the position number note will follow the stiffener line.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 180 of 517
Product Release Letter
Curved Hull:

Incident Issue Description


Number Number
110390 240241 Title: redundant function is not working for curved panel
Symptoms: Not possible to reject a hole in Hole Management for a Curved
Panel.
Previous/Known workaround: No known workaround exists.
Solution: Reject managed hole failed when more holes were added after the
approval of the managed hole. With this fix the reject operation will work.
117432 259405 Title: Y - COG of CSTIFF not immediately updated after profile split symmetry
Symptoms: Splitting a symmetrical Shell Propfile into separate PS and SB profile
shows wrong CoG on the SB side profile in the Search Result utility.
Previous/Known workaround: No known workaround exists.
Solution: The starboard specific shell profile is now verified and updated with the
correct WCOG information. There is no need to recreate the shell profile to
update these values any more.
119569 266444 Title: Profile annotations disappear after view recreate on Curved Panel View
Symptoms: Annotations for a Curved Panel view is blanked out when using the
function Recreate View for such symbolic view.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the annotations are kept after
view recreate.

Hull Production:

Incident Issue Description


Number Number
108180 232755 Title: When running ppanparts, Each markings has MARKING SIDE=BOTH.
Symptoms: It is not possible to set markingside for markings on planar panels
other than for free text marking.
Previous/Known workaround: No known workaround exists.
Solution: Marking side for all marking types has been opened up so correct side
is set in the generic file.
This handles only the marking that is set via marking statement (MAR) in Planar
Hull.
119207 265383 Title: MANSTIFF with incorrect end values when more than one panel is selected
Symptoms: Using same PosNo for same HSTIFF across PS/SB are used.
Problem is that MANSTIFF changed End1 from Left to Right when more than
one HPANEL is selected.
Previous/Known workaround: This happens when MANSTIFF_COMBINE=YES in
the SB_PROF_RESTRICT file.
Solution: Corrected so the ends are correctly presented in the list.
266596 Title: Enhancement to change the size of VMARK for Ppanparts.ip
Symptoms: The marking VMARK is of a fixed size compared to CMARK where it
is possible to modify the size.
Previous/Known workaround: N/A
Solution: Parameters have been added to the IP VMARK:
VMARK,[[ALWAYS_MOULD,[[<width>,<height>,]]]

If ALWAYS_MOULD is to be left out, there must be a commaseparator anyway,


VMARK, , <width>, <height>,

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 181 of 517
Product Release Letter
Incident Issue Description
Number Number
122373 274124 Title: The inverse bending curve of the Shell Profile is incorrect after Profile
Sketch and List.
Symptoms: See title
Previous/Known workaround: No known workaround. This error was
introduced in 12.1 SP4 Fix 44.
Solution: Corrected reflection of inverse bending curve.

Marine Drafting:

Incident Issue Description


Number Number
121549 271641 Title: POSNO not allong stiffeners anymore.
Symptoms: Adding a stiffener position number without any reference lines will
place the position number note in strange directions and not along the stiffener.
Previous/Known workaround: Make a small reference line along the stiffener.
Solution: Corrected tso the position number note will follow the stiffener line.
121550 271642, Title: Curve length
271675 Symptoms: In SP4.44 or SP5.4 it is not possible to create Curve Length
dimension anymore
Previous/Known workaround: Include shell saems in the view and measure
along those.
Solution: The problem has been solved so that it is possible to measure curve
length for Curved panel plates. The seams in the panel has to be indicated.

Pipe Fabrication:

Incident Issue Description


Number Number
116739 257550 Title: Pipe Fabrication: FTUBs corresponding to pipe end preparations should
have MTOC OFF
118777 264273 Title: PF issues with views and dims in Marine Drafting
119353 266071 Title: PF issues with single view
Symptoms: See title.
Previous/Known workaround: No known workaround.
Solution: Noticed issue with master view formation and refactored it.
120882 269713 Title: When pipe sketch has more than one ATTA to show, not all are
dimensioned
Symptoms: NA
Previous/Known workaround: NA
Solution: Issue is now fixed.

Outfitting:

Incident Issue Description


Number Number
77534 169776 Title: Piping - Invalid HREF/TREF Entries No Longer Break Pipe
Creation/Modification Form
Symptoms: When the HREF or TREF of a branch had its referenced entity
deleted once set and locked, creating an invalid reference, the pipe
creation/modification form failed to load and an error message appeared.
Previous/Known workaround: Keeping the branch unlocked when deleting
entities prevented deleted references appearing as invalid.
Solution: The code now checks that the reference exists and handles the error
properly. The form now works as it should.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 182 of 517
Product Release Letter
Incident Issue Description
Number Number
98890 212045 Title: Design - EventPoint for Track |DBCHANGE|issues.
Symptoms: EventPoint for Track |DBCHANGE| is different in recent versions
when an element is dropped to a new position with the Model Editor.
Previous/Known workaround: No known workaround.
Solution: Track[DBCHANGE] event fires when an element is dropped at a new
position with the Model Editor.
103072 221181 Title: Isodraft - RADIUS column of the iso bending table has wrong information
within
Symptoms: RADIUS column of the iso bending table has wrong information
within
Previous/Known workaround: None
Solution: Allow for Overall Diameter bend radius specification.
109568 257956 Title: Material List incorrect when slanted FTUBs used
Symptoms: Tube quantities incorrect.
Previous/Known workaround: None
Solution: Add slanted FTUB lengths as tube excess.
117195, 258236, Title: Piping - Model editor linear incrementing works unreliable
117404 259266 Symptoms: Pipe components drag starting point doesn't match desired position
(jumping over)
Previous/Known workaround: None
Solution: Corrected the projection of drag starting point.
119113 265163 Title: Use Within Volume option in Mass Properties>Volume form
Symptoms: Head tube of branch wrong values for "inside" option
.Previous/Known workaround: None
Solution: Now fixed.
120124 267429 Title: Design - Very poor performance when selecting claimed elements from
extracts
Symptoms: It takes up to 5 minutes for the application to become responsive
again after selecting a single element claimed in a middle extract
Previous/Known workaround: Unknown
Solution: The element selection processing has been optimised and now it is
almost instant, with test extracts provided by a customer.
120313 268207 Title: Design - PCLA spref with Cmpref crashes PSATTS query
120492 268900 Title: Isodraft - Line slope rate is not expressed on ISO drawing.
Symptoms: Line slope rate is not expressed on ISO drawing.
Previous/Known workaround: None
Solution: If fall is significant (> 0.25deg.), do not ignore even if actual fall is less
than 1mm.

12.1.SP4.44

Initial Design:

Incident Issue Description


Number Number
94971 202947 Title: Bad performance selecting and creating damage case reports
Symptoms: Slow update of selection dialog, large report causing creation to fail.
Previous/Known workaround: None
Solution: Code change applied.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 183 of 517
Product Release Letter
Planar Hull:

Incident Issue Description


Number Number
75063 154185 Title: Marking text arrangement for S-side panel of SBP panels.
Symptoms: Marking text on a symmetrical panel in a frame section will on te SB
side be marked outside the panel.
Known workaround: No known workaround exists.
Solution: Corrected so the text on the relfected panel will be adjusted to be
marked inside the panel.
81505 175614 Title: Wrong View Creation(Detail View)
Symptoms: The function Detailed View --> 2 CP, are not affected by the default
values of VIEWX, VIEWY or VIEWZ.
Previous/Known workaround: Manually turn the symbolic view into correct
viewing direction.
Solution: The default vaues VIEWX, VIEWY and VIEWZ now have effect when
generating detail view 2CP.
99031 223001 Title: If the neighboring edge does not have bevel, the chamfer is not generated
in gen file
Symptoms: See title
Previous/Known workaround: Add bevel to neighbour.
Solution: The calculation of chamfer done when running Planar Panel Parts
Generation has been corrected. If the first panel had butt bevel and the second
panel does not have bevel defined chamfer will still be calculated.
105683 227082 Title: The end reference of syntax bracket does not work properly.
Solution: Bracket / Bracket is now handled in a different way than Bracket /
Flange, which was not the case before.
110723 240884 Title: Planar stiffener type 54 with endcut 19210 creates SB error 6139
Symptoms: When creating a stiffener, using endcut type 191 - 201, the error
message:
"Error when transforming stiffeners in contour 0!
HULL object ER2-BHD-FR35-1 causes SB-error 6139"
Previous/Known workaround: This happens when not all parameters are given.
The defualt handling of non given paramters are not fully working for those types.

In the documentation the b measure is marked as an optional parameter for


endcut types 191, 192, 193, 194, 195, 196, 199, 200 and 201.
This is currently not true; you need to define a valid b-measure (cf. endcut
sketches) to avoid SB-error 6139.
Solution: The interpretation of the end cut parameters for endcut types 191, 192,
193, 194, 195, 196, 199, 200 and 201 have been corrected so that default values
are recognised.
110857 241165 Title: The colour of marking will be set automatically in the scheme after store the
panel.
Symptoms: The colour of marking will be set automatically in the scheme after
store the panel.
Solution: Corrected so that the system will no longer incorrectly add colour to the
marking statement.
115212 253409 Title: When recreate the panel, the bracket size is automatically resize.
Symptoms: When recreating a planar panel that contains a bracket, defined by
syntax 2 and the A and B measures are defined perpendicular (negative values),
the bracket gemoetry are changed by the system.
Previous/Known workaround: Either run the panel schema statement or update
the bracket via the Statement Wizard after the panel has been recreated.
Solution: The problem has been solved so that the bracket is not resized when
doing recreate of the panel.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 184 of 517
Product Release Letter
Incident Issue Description
Number Number
115846 255234 Title: A fatal error occured when running the scheme of knuckled panel.
Symptoms: A fatal error occured when running the scheme of knuckled panel.
This problem occur in almost all knuckled panel crossections.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the crossection of knuckled panels will not give fatal
error.
116101 255819 Title: The Angle values of Aparms and parm does not output in Attributes of
HSTIFF.
Symptoms: The angle is missing in the attribute.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the parameters are available.
116168 255962 Title: When modify cutout, the Clip info are disappear in GUI.
Symptoms: When modify cutout, the Clip info are disappear in GUI.
This happens when a named cutout does not contain any clips, but the clip is
added in the schema outside the named cutout.
Previous/Known workaround: Add the clip in the named cutout description.
Solution: If a named cutout is used and additional clipsare added the
StatementWizardwill now handle the additional clips correctly.
116694 257356 Title: The flange bevel of pillar is not work properly.
Symptoms: When defining bevel on the flange of a Pillar, the Pillar cannot be
modified with help of RMB. System may eventually abort
Previous/Known workaround: Modify such Pillar in schema.
Solution: Error corrected so that bevels for pillar will now work correctly.
117994 261348 Title: Problem not to properly display the line and endcut symbol of stiffener with
hang in symbolic view
Symptoms: When stiffener displacement (hang) is given the stiffener loses the
endcut symbols and the line is always drawn as a solid line.
Previous/Known workaround: No known workaround exists.
Solution: By activating the keyword STI_UNSYM_ECUTSYMB in the Hull
Modelling default file, the stiffeners will be presented with correct linetype and
endcut symbols also when stifener displacement (hang) is given.
118830 264393 Title: Panel disappears from view when running scheme from first line
Symptoms: When a schema is run from the top, added information and the
panel disappears from the drawing in case there is an error in the schema. If
statements are run one line at the time, the information remains on the drawing.
Previous/Known workaround: Do not run from the top but start at panel or
boundary statement.
Solution: Run all on a scheme with an erroneous statement now ok also if
starting at the ident line instead of starting from the panel statement.
119765 266809 Title: Panel disappears from view when running scheme from first line
Symptoms: When a schema is run from the top, added information and the
panel disappears from the drawing in case there is an error in the schema. If
statements are run one line at the time, the information remains on the drawing.
Previous/Known workaround: Do not run from the top but start at panel or
boundary statement.
Solution: Run all on a scheme with an erroneous statement now ok also if
starting at the ident line instead of starting from the panel statement.

Curved Hull:

Incident Issue Description


Number Number
93271 199604 Title: XML Output of Specific Hull Curve Crash
Solution: The problem has been solved so that Both curves can be exported
without error or crash.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 185 of 517
Product Release Letter
Incident Issue Description
Number Number
113038 246632 Title: XML export of hullcurve by general cylinder
Symptoms: It is not possible to export hullcurve defined by general cylinder to
XML file. After using: "Curved Hull - Batch -Output XML", indicating a curve and
selecting file name - the following error occurs:

XML Out: Error while processing object "CURCYL12": The object 'CURCYL12'
does not exist!
XML Out: Error Code 43001!

Solution: The problem has been solved so that hullcurves by general cylinder
are exported in XML also in this project.
114636 251584 Title: Splitting Shell Stiffener gives strange ends and additional strange profiles
Symptoms: Having a shell profile on the material side of shell plates, crossing
two plates with different plate thicknesses may give a strange profile end shape
when the shell profile is split by the seam.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the splitting of shell stiffeners is
done correctly without strange ends.
114825 252288 Title: Shell stiffener trace does not consider shell plate thickness
Symptoms: The variable SBH_ENABLE_SOLID_PLATES is defined and set to
TRUE but there is no effect on the shell plates.
Previous/Known workaround: Set the value to YES.
Solution: Modification so the variable can have any value. It just needs to be
defined.
115107 253264 Title: ShellX - Dropped PosNo not aligned with Cstiff trace
Symptoms: When annotating a ShellX view it is possible to use Annotate -> Hull
Note -> PosNO, to select a single Cstiff and then to drop a PosNo for a Cstiff
simply aside the trace of the Cstiff, instead to create a reference. The direction of
PosNo shall be aligned with the Cstiff trace automatically then. Unfortunately the
system uses the trace's tangent for the END2 of the Cstiff in ShellX view instead
the tangent for the point where the Cstiff was selected before the PosNo has
been dropped. This is causing inconveniences especially i.w.o. the forward and
aft shoulder of the ships surface.
Previous/Known workaround: None
Solution: The problem has been solved so that the PosNo's are aligned
with the shell stiffeners trace.
115833 255217 Title: No write access to HCMWLD can spoil curved panel.
Symptoms: A user PHULL does not have write access to database containing
HCMWLD. This user runs the function (in Curved Hull or Structural Design)
Curved - Model - Recreate. Then - all shell plates are removed from a curved
panel. If this user stores the panel and uses SAVEWORK - the curved panel is
destroyed. For a test case in MAR project - please refer to the attached
document.
Solution: The system will now abort both recreate and modify scenarios where
parts are involved if any panel parts are locked/not accessible. This could stop a
possible acceptable operation, but it is the prudent thing to do.
115995 255683 Title: cplates are drawn in 2 colours. Cyan confuse all users.
Symptoms: A shell plate that belongs to a curved panel is still drawn in cyan
colour. It should be green.
Previous/Known workaround: No known workaround exists.
Solution: SB specific plates that belongs to a cyrved panel gets wrong
colour.THis is now corrected so they are also drawn as green.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 186 of 517
Product Release Letter
Incident Issue Description
Number Number
116256 256178 Title: cplates with holes via curves as outer contour not OK for production.
Symptoms: Holes when presented in Curved Panels are not correctly presented.
When the hole is going outside of panel boundary, the boundary is not cut of by
the hole.
Previous/Known workaround: No known workaround exists.
Solution: Holes in the Curved Panel will be cutout from the panel.
The full hole contours will however been shown if the plate is presented.

Hull Structural Design:

Incident Issue Description


Number Number
245945 Title: Plate of the portside panel is named with suffix -SP- after block division
when the new panel generated is valid only for portside.
Symptoms: Plates of the portside panels are named as -SP- when they are
generated as a result of block division, using a cutter which is running at positive
location. The cutter is dividing the panel in two parts, one as OverCL and another
one as portside panels.
Solution: Plate name suffix are now syncronized with the panel location.

Hull Production:

Incident Issue Description


Number Number
92567 198454 Title: The GSD marking is strange with curved flange.
Symptoms: GSD on the plate for a curved flange along the boundary is not
perpendicular to the flange.
Previous/Known workaround: No known workaround exists.
Solution: The GSD marking on plates for curved flanges has been updated.
94975 202967 Title: Reverse straignt line of defined shrinkage is outputted incorrectly.
Symptoms: The Inverse Bending Curve for Shell Profiles may get distorted in
case Shrinkage is used for the profile.
Previous/Known workaround: No known workaround exists.
Note, there is no problem if no shrinkage is used.
Solution: Curve is corrected so it is corret when shrinkage is defined.
101563 217810 Title: Exported copy assistant file will not transfer its attribute.
Symptoms: Exported copy assistant file selected Manufucturing data will not
transfer its attribute on imported project.
Previous/Known workaround: No known workaround exists.
Solution: Data base attributes has been changed CopyAssist will handle the
MANU attributes in the transfer.
109995 239383 Title: Distance Required In Bending Template Table
Symptoms: Missing rows
Previous/Known workaround: N/A
Solution: Added missing distance information (DISTTEM, DISTPL,ANGLE).
115004 252978 Title: ’Material list for Nesting’ applied for nested profiles got wrong result.
Symptoms: Nesting report does not distinguish different profile nests QUALITY
of raw profile sizes are same.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that nested profile parts with differing quality are not
counted together.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 187 of 517
Product Release Letter
Incident Issue Description
Number Number
114802 253285 Title: Issue of double bulb's weight
Symptoms: The weight of a double bulb is not correct (profile type 40 and
SBH_DOUBLE_BULB defined). It is calculated as an ordinary T-bar.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that double-bulb geometry is considered when weight is
calculated.
117664 260519 Title: The notch position in the profile sketch of the shell stiffener (Over In CL) is
wrong.
Symptoms: Making a notch for a relfected shell seam on a shell profile that is
defined over center line will show the notch wrongly on the profile sketch as it
was not for the reflected seam.
Previous/Known workaround: No known workaround exists.
Solution: Curved panel parts generation corrected so that reflection of notches
on stiffener in/over CL is considered.

Hull Nesting:

Incident Issue Description


Number Number
110679 240786 Title: Bevel change at limit, gap are not set when nesting from parts menue
Symptoms: In 12.1.SP4 Fix 41 it was introduced to add gaps where there are
bevel changes on the same limit. This is working properly when nesting such part
via "By Name". However, no gaps are set when nesting the same part via the part
menue.
Previous/Known workaround: Use "By name" when nesting parts.
Solution: Corrected so also the gaps are handled when nesting via the parts
menu.
115994 255970 Title: System error 2519
Symptoms: When deleting a start defined for a label, System error 2519 is given
and the start cannot be removed.
Previous/Known workaround: Delete the whole label text.
Solution: Corrected so also label starts can be removed without gettingh system
error 2519.
118314 263402 Title: Nest_Text Error
Symptoms: Bevel is setup with wide chamfer. Using a bevel type 30 with variant
1 gives wrong value for the chamfer.
Previous/Known workaround: No known workaround exists.
Solution: The calculation of chamfer is corrected for wide chamfer for this type
and variant.

Marine Drafting:

Incident Issue Description


Number Number
47868 Title: Tribon M3 line types not implemented in PDMS
Symptoms:
All Tribon M3 line types that was not directly mapped to an existing PDMS line
type have not yet been implemented in PDMS.
This is apparent when we start to persist contours into PADD in 12.1.
Solution: Tribon "special" line types, like "Track" have so far been changed to
PDMS "Solid Wide" during persisting. The solution is to persist the Tribon
"special" line types intact. Note that Tribon "special" line types will not be handled
by PDMS Outfitting Draft (here they still will be displayed as "Solid Wide").
Also included in this solution is that the functions Modify/Linetype, Modify/Colour
and Modify/Layer will now persist the result.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 188 of 517
Product Release Letter
Incident Issue Description
Number Number
109598 237657 Title: Problem to change the line type after stretch the geometry
Symptoms: the line type of geometries is changed after stretch the geometry
(Modify - Stretch)
Previous/Known workaround:
Solution: Tribon "special" line types, like "Track" have so far been changed to
PDMS "Solid Wide" during persisting. The solution is to persist the Tribon
"special" line types intact. Note that Tribon "special" line types will not be handled
by PDMS Outfitting Draft (here they still will be displayed as "Solid Wide").
Also included in this solution is that the functions Modify/Linetype, Modify/Colour
and Modify/Layer will now persist the result.
116146 255912 Title: Drafting default of drawing revision option "KEEP_SESSION_FILES : No"
does not apply on UNC path with containing $ character
Symptoms: UNC path with containing $ character is not handled.
Previous/Known workaround: No known workaround exists.
Solution: Changes were made to include '$' as a valid character in file path.
117366 259725 Title: Fuction "File Open" & "List"
Symptoms: Currently when press Open Drawing the drawing type is fixed as
"General Drawing". After changing the type and re-entering the function it is back
to "General Drawing".
Previous/Known workaround: Manually change to the desired drawing type.
Solution: Initial drawing type will be the last used drawing type also when
drawing type is “All Drawings”.
Because of this, the drawing list will remain until next invocations of File Open
dialog.
Note:
- The system start-up initial Drawing Type will still be “General Drawings”.
- When changing drawing type, the drawing list will still be scratched (except
when drawing type is changed tp "All Drawings").
117713 260356 Title: New MarAPI to insert plate part.
For more information refer to section Enhancements above.
117794 260501 Title: Automatically update backingsheets
Symptoms: Backingsheets are not automatically updated when HVAC sketches
are generated causing extra clicks to be necessary.
Previous/Known workaround: Run the command "update bsheets" on every
sketch that needs it.
Solution: Added a line to the PML code that calls the command "update bsheets"
upon HVAC sketch creation.
118815, 264299, Title: Fatal error observed for model info through Event points
118762 264319 Symptoms: If user indicates a model after selecting Option at the model
262973 information function, application aborts.
Previous/Known workaround: No known work around exists.
Solution: When identifying by "event point{" is is assumed that user wants
specifically to identify a hole (in panel) or at least a hull model. Using "event
point{" to identify an outfitting model is not recommended and will only result in a
"Model information not available" message (instead of a crash).

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 189 of 517
Product Release Letter
Pipe Fabrication:

Incident Issue Description


Number Number
109169 236439 Title: 'Modify Spool'- unable to change spool's limits!
Symptoms: Pipe Fabrication is generating too many spools, which leads to an
inconsistency between Pipe Fabrication and Spooler.
Previous/Known workaround: None
Solution: One of the we use internally to get attribute of a certain type were not
working as expected, as a result the logic in the code was not executing as
expected. The method that was at fault has now been corrected and the logic in
the code for generating spools via Pipe Fabrication now works as expected.

Outfitting:

Incident Issue Description


Number Number
74930 153716 Title: Design - Piping component creation form aid graphics handling improved
Symptoms: Aids not belonging to the component creation form are removed.
Known workaround: Keep reinstating grid aids every time that they are
removed.
Solution: Improved graphical aid deallocation on the component creation form.
75116 154314 Title: Piping - Piping component creation form aid graphics handling improved
Symptoms: Aids not belonging to the component creation form are removed.
Known workaround: Keep reinstating grid aids every time that they are
removed.
Solution: Improved graphical aid deallocation on the component creation form.
87897 187878 Title: Reporting: 12.1.SP4 Command LIKE in calculated field
Symptoms: Not getting items expected from this expression
Previous/Known workaround: N/A
Solution: Report now includes items expected according to Like criteria.
94400 201799 Title: PDMS12.1.SP4: DIAREF attribute is not available for SCPLINE in DESIGN
in TTY mode
Symptoms: unable to get diaref for SCPLINE in tty mode in design module
Previous/Known workaround: Get dairef from SCSEG
Solution: Dairef available for SCPLINE
102522 219976 Title: Spooler - Dabacon Error 18 crash when generating SPOOL isometric
Symptoms: Dabacon Error 18 crash.
Previous/Known workaround: None.
Solution: Do not look for bolts at a branch.
103286 223230 Title: Piping - Inconsistent BRAN head bore is not reported when checking the
pipe
Symptoms: No warning for bad HBORE/HSTU
Previous/Known workaround: Manual check
Solution: Now fixed.
104694 224746 Title: Spooler - Dabacon Error 18 when generating SPOOL isometric
Symptoms: Dabacon Error 18 crash
Previous/Known workaround: None
Solution: Do not look for bolts at a branch.
106794 229602 Title: Draft - Dxf export of unnamed user defined linestyles with PATREP.
111411 242916 Title: Spooler - Spool breaks applied incorrectly for mitred bends
Symptoms: Incorrect Spools created.
Previous/Known workaround: None
Solution: Apply Spool breaks correctly for mitred bends.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 190 of 517
Product Release Letter
Incident Issue Description
Number Number
111694 242993 Title: Spooler - Spool breaks should not be set on mitred bends
Symptoms: Allows spool breaks to be set on mitred bends
Previous/Known workaround: None
Solution: Prevent spool breaks being set on mitred bends.
111934 243583 Title: Piping - The user is unable to select the bend O/D multiplier on the
component selection form
Previous/Known workaround: The bend radius can be set using the attributes
form or the command line.
Solution: The code which caused the problem has been identified and
removed.
112308 244837 Title: Spooler - Spools created incorrectly when Create Spool Break PA used on
COUP at branch end
Symptoms: Single component Spool created for COUP
Previous/Known workaround: None
Solution: Set Spool Break attributes correctly.
108759 250557 Title: Isodraft - Isodraft Query - MTO column width
Symptoms: When using True Type font, then the program does not take account
of the characters being proportional font and there is a lot of unnecessary white
space in the MTO.
Previous/Known workaround: None
Solution: If using True Type font, then the program needs to take account of the
characters being proportional font to find the actual length of string and adjust
required space accordingly.
114943 252685 Title: Piping - Piping Editor Mode Valve Error.
115297, 253656, Title: Sheet Scale Factor not applied to linestyle pattern
115299 253655 Symptoms: N/A
Previous/Known workaround: N/A
Solution: Sheet Scale is now applied when linestyle defined for ACad Export.
117000 258157 Title: Isodraft - Screw mark is displayed on wrong position for LJSE.
Symptoms: Screw mark is displayed on wrong position for LJSE.
Previous/Known workaround: None
Solution: Watch out for user-positioned end connections before LJSE.
117193 258229 Title: Piping - Model Editor can move pipe components outside the pipe line in
Pipe Editing mode
Symptoms: Components positioned outside the pipe route.

118178 262296 Title: Isodraft - Isodraft material, gasket display issue.


Symptoms: Gasket reported in one side of the flange regardless of spec.
change.
Previous/Known workaround: None
Solution: Check if gasket appears before spec. change in flange pair.
118214 262736 Title: Design - Model Editor can move pipe components outside the pipe line in
Pipe Editing mode
Symptoms: Components positioned outside the pipe route.
Previous/Known workaround: None
Solution: Model Editor can no longer move pipe components outside the pipe
line in Pipe Editing mode.
118426 263297 Title: RreviewExport error for EQUCOM.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 191 of 517
Product Release Letter
12.1.SP4.43

Planar Hull:

Incident Issue Description


Number Number
101028 216480 Title: Syntax3 bracket error occured on Dotori.
Symptoms: In some cases, the arm of a bracket gets a curvature when it should
be straight.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so when no curvature exists, the bracket arm will be straight,
following the attached plane.
110020 238591 Title: Bevel Color does not work for some of hull components
Symptoms: If variable bevel is defined for stiffeners (end/trace) and/or brackets,
the bevel color is not shown in symbolic views.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so color is correctly displayed for stiffener end and trace and
also for brackets, when variable bevel is defined.
111279 242132 Title: The bevel code will be removed when input the negative(-)bevel in Scheme
Editor.
Symptoms: Bevel codes that is given a negative code in clips, are removed from
the schema, e.g. BWE=-450 is removed by the system.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so bevel codes with negative (-) bevel will be handled and
not removed from the schema.
113283, 247329, Title: Structural design crash when using boundary wizard.
112518 247461 Symptoms: See title
Previous/Known workaround: This often happens when there is a Shell
expansion view in the drawing. By removing this view, the wizard will not abort.
Solution: Corrected so also the shell expansion view can be present in the
drawing when using the boundary wizard.

Curved Hull:

Incident Issue Description


Number Number
27217 68902, Title: Problem with angle keyword are omiited in xml.
150530 Symptoms: When creating shell profiles by using 2point + angle, if angles are
defined as the perpendicular, the angle key words are omitted in the output xml.
Previous/Known workaround: No known workaround exists.
Solution: The Issue has been solved so that it's possible to export a profile
created by using 2points+angle and setting the angles as perpendicular and
keeping the keywords in the xml export file.
102334 219491 Title: Curved Hull - CPAN error when HCMWLD is read-only
Symptoms: When using Global - HCMWLD database is primary at the location
where curved hull panels are created. At this location BLOCK database is not
primary (read-only). However - the users tried to create CPANEL and collected
CPLATE & CSTIFF elements to CPANEL. No error warning was raised by the
system. CPAN & CSTIFF received a PARNAM attribute related to CPANEL, but
CPANEL was not stored. It is not possible to remove this attribute of CPLATE &
CSTIFF - they need to be deleted and created from scratch.
Previous/Known workaround: It is not possible to remove this attribute of
CPLATE & CSTIFF - they need to be deleted and created from scratch.
Solution: An error is raised if the block is not claimable and no action is taken.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 192 of 517
Product Release Letter
Incident Issue Description
Number Number
106727 229532 Title: Shellplate compensation causes incorrect splitting for cstiffs.
Symptoms: When a shell stiffener is split and is crossing two plates with different
plate thickness, the resulting stiffeners are wrong. There is a strange bend at the
stiffener end.
Previous/Known workaround: No known worksround exists
Solution: The problem has been solved so that the profile is splitted without
endparts being bent down at the splitting point.
236826 Title: Shellplate compensation causes incorrect splitting for cstiffs.
Symptoms: When a shell stiffener is split and is crossing two plates with different
plate thickness, the resulting stiffeners are wrong. THere is a strange bend at the
stiffener end.
Previous/Known workaround: No known worksround exists
Solution: The problem has been solved so that the profile is splitted without
endparts beeing bent down at the splitting point.
110150 238988 Title: SBH_ENABLE_SHPLACOMP: Wrong plane panel contour.
Symptoms: The final part contour shape of a deck panel differs some 3-4 mm
when using SBH_ENABLE_SHPLACOMP.
Previous/Known workaround: None
Solution: The approximation routine for shell plates has been improved to give
more aqurate result.
This means that the shell plates have to be regenerated to get the improved
result.
112641 245410 Title: Shellplate compensation causes incorrect splitting for cstiffs.
Symptoms: When a shell stiffener is split and is crossing two plates with different
plate thickness, the resulting stiffeners are wrong. THere is a strange bend at the
stiffener end.
Previous/Known workaround: No known worksround exists
Solution: The problem has been solved so that the profile is split without
endparts beeing bent down at the splitting point.

Hull Production:

Incident Issue Description


Number Number
110003 238588 Title: SBH_BKT_SMALL_TOE_NO_COMP does not work with AutoBevel
Symptoms: In case of Auto Bevel resulting in a bevel, the variable
SBH_BKT_SMALL_TOE_NO_COMP has no effect. The toe is always
compensated.
Previous/Known workaround: Use fixed bevel code.
Solution: Variable SBH_BKT_SMALL_TOE_NO_COMP will also be handling
the case where AutoBevel is used for brackets.

Hull Nesting:

Incident Issue Description


Number Number
90394 193787 Title: Customer needs possibility to add automatically all available starts ( marks,
labels...etc) at once
Symptoms: Customer needs possibility to add automatically all kind of starts (
marks, labels...etc) at once in order based on his nest default settings.
Previous/Known workaround: N/A
Solution: The function automatic start has been extended to handle all the start
types as given by the working sequence amd in the correct order. It is available
in interactive nesting, one-part nesting and automatic nesting via the Plug-in.
If the nesting default WORKING_SEQUENCE = 'Undefined', the automatic starts
are created as before.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 193 of 517
Product Release Letter
Incident Issue Description
Number Number
108589 234488 Title: When prod info. is registered as 2D, Plate part is missing information as
area/weight.
Symptoms: When production information is registered as 2D, Plate part is
missing information as area / weight.
Previous/Known workaround: No known workaround available.
Solution: Corrected so information such as area and weight is updated.

Marine Drafting:

Incident Issue Description


Number Number
19563 237582 Title: Hidden Layers
Symptoms: If an origintaor o0f a drawing hides some layers in his drawing, then
of course some of the drawing content will not be shown (acc. to layer setup) . If
somebody else than the originator than opens this drawing with the (stored)
hidden layers this person will not know, that some of the drawing content is
hidden.
Previous/Known workaround: N/A
Solution: Issue solved by introducing a new Marine Drafting Default keyword
LAYER_STATUS_REPORT_CONFIRM.
Valid valuse are
- Always
- Never (system default)
The keyword is trigged in functions
- File/Open
- File/New
- marapi DwgOpen
- marapi DwgNew
113759 248672 Title: The showing Insert Model GUI is too annoying after 12.1.SP4.37.
Symptoms: The progress bar is shown also when the amount of objects are
small which is annoying
Previous/Known workaround: No known workaround exists.
Solution: The Progress Bar was introduced in Fix 37 as a UI improvement,
informing the user about the progress when updating design (updating big views
takes a long time, something that user might experience as program is
hanging). The problem for customer now is that the Progress Bar is
"unnecessarily" displayed also for small ammount of model information drawn,
resulting in an annoying "flickering" (the progress bar is visible only for a short
period of time).
The solution is to disable Progress Bar when model content is small/moderate.
113784 248787 Title: MarAPI - ViewSectionNew method error with block and panel filter
Symptoms: When using the filters SetPanelsFilter and SetBlocksFilter in the
same object, the system aborts.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so both filters can be used together.

Schematic 3D Integrator:

Inciden Issue Description


t Number
Number
83311 177326 Title: Update Attributes for a multiple link updates only first object
Symptoms: Other linked objects do not get updated attribute values
Previous/Known workaround: Manual update.
Solution: All linked objects are now updated.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 194 of 517
Product Release Letter
Engineering:

Incident Issue Description


Number Number
104089 223923 Title: Compare/Update - Pseudo-attribute doesn't work with the CUB in DESIGN
Symptoms: Unable to compare a pseudo attribute on destination side
Previous/Known workaround: N/A
Solution: Now able to enter a pseudo attribute in destination side when update is
off for that row.

Multi-Discipline Supports (MDS):

Incident Issue Description


Number Number
246957 Title: Added Compaitbility for creating Hanger Supports with the LICAD V10
Interface
Symptoms: It was not possible to use the MDS application with the LICAD V10
hanger interface.
Previous/Known workaround: NA
Solution: We have updated the calls to the LICAD interface to allow compatibility
with LICAD V10. The MDS application is still compatible with previous versions of
LICAD.

Outfitting:

Incident Issue Description


Number Number
39168 66966 Title: Draft - AutoDraft missing R_DEF files for versions after ACAD 2007
Symptoms: The files that are present under the autodraftACAD folder only refer
to R2006 & R2007, there are no references to the other versions.
Known workaround: Request the R_DEF files from Aveva support
Solution: The file that is relevant to versions after 2007 is eg
pdmsbackR_DEF.cui for backing sheets. You use R_DEF everywhere that
R2007 was used (eg set PDMS_ACAD=R_DEF). These files ought to be present
in the installation but was missing. They have now been added.
73947 151542 Title: Piping - Correct choice of TEE bore sizes shown on pipe component
creation form
Symptoms: In some cases, an incorrect choice of bore sizes is shown.
Previous/Known workaround: Restart form or command line Choose
command.
Solution: Correct choice of bore sizes shown.
94746 202673 Title: Report Designer : Sorting calculated Field
Symptoms: Sorting of calculated fields is not available
Previous/Known workaround: N/A
Solution: An upgrade of the third party components has made this available.
105030 225601 Title: UNABLE TO RESIZE THE VIEW IN 3D VIEW OF DRAFT AFTER
INSTALLING 12.1.SP4 Fix.36 – PDMS
Solution: Cursor now changes to correct resize symbol and it is possible to
resize the view.
107262, 230508, Title: Piping - Correct choice of OLET bore sizes shown on pipe component
56030 94014 creation form
Symptoms: In some cases, an incorrect choice of bore sizes is shown.
Previous/Known workaround: Restart form or command line Choose
command.
Solution: Correct choice of bore sizes shown.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 195 of 517
Product Release Letter
Incident Issue Description
Number Number
108443 233251 Title: Piping - Correct size bend created for pipes with no bending machine
specified
Symptoms: Repeated error message shown, and incorrect bend radius applied
Previous/Known workaround: None
Solution: Fix bend radius calculation code.
99042 235858 Title: HVAC - An HVAC branch would not connect to P3 a Centrifugal fan
Symptoms: Error alert displayed. System was trying to set CREF instead of
CRFA attribute of HFAN
Previous/Known workaround: Command line
Solution: Fixed.
110604 240677 Title: Resolved pipe component form PML error when last branch component
has a bad spref
Symptoms: PML error shown when last branch component has a bad spref
Previous/Known workaround: Correct the bad component spref
Solution: Check for bad component spref.
112308 244837 Title: Spooler - Spools created incorrectly when Create Spool Break PA used on
COUP at branch end
Symptoms: Single component Spool created for COUP
Previous/Known workaround: None
Solution: Set Spool Break attributes correctly.
112653 245503 Title: GETWORK may freeze if BACK, LALB, or SYLB have been modified.
Symptoms: See title.
Previous/Known workaround: N/A
Solution: The nesting of the loops causing the problem has been broken so that
they are now executed one after the other.
110023 245585 Title: Isodraft - Manual Ball Valve Lever Direction
Symptoms: Valve Lever does not point in the flow direction flow (as shown in the
documentation)
Previous/Known workaround: None
Solution: Ensure Valve Lever points in the flow direction.
114488 250964 Title: Desing - LUGS now work with PDMS 12.1.SP4
Symptoms: Unhandled Database error 18 from DGETF
Previous/Known workaround: None
Solution: Code ported back.

12.1.SP4.42

Copy Assist:

Incident Issue Description


Number Number
105615 226791 Title: CopyAssist functionality in batch
Symptoms: Enhancement to run CopyAssist via script
Previous/Known workaround: -----
Solution: . For more information refer to section Enhancements above.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 196 of 517
Product Release Letter
Planar Hull:

Incident Issue Description


Number Number
92981 199173 Title: SBH_ADJUST_ENDCUT is not enabled along surface for the end of Invert
Angle.
Symptoms: When a profile is atttached t othe surface and supposed to be
handled by SBH_ADJUST_ENDCUT to get correct endcut shape, the profile is
intersecting the surface.
Previous/Known workaround: No known workaound exists.
Solution: The problem has been solved so that the endcut to surface get correct
shape for the stiffener.
90854 208970 Title: Consideration to chamfer in bounding panels is not properly taken for X or
Y bevel
Symptoms: When usingSBH_WIDE_CHAMFER, the abutting panel boundary
does not get correct chamfer.
Previous/Known workaround: No known workaround exists.
Solution: Correction is done to get the chamfer geometry for wide chamfer
handling.
97991 210120 Title: Bracket instance error
Symptoms: A bracket (e.g. type KL) is defined with a bracket instance (e.g.
KL10). If a bracket type has been changed (e.g to "B") – the previously selected
bracket instance is still valid and cannot be changed.
Previous/Known workaround: No known workaround exists
Solution: The bracket instance field will be cleared when bracket type is
changed.
107513 231213 Title: M1 (Width) of Cutout is removed when recreate the panel.
Symptoms: If defined the C(Slope), M1(Width) and M3 at the same time in the
Cutout, M1(Width) of Cutout is removed when recreate the panel.
However, M1 value remain on the Cutout if activated the panel.
Previous/Known workaround: No known workaround exists
Solution: Cutout will now keep the width (M1) also after recreate.
109434 237304 Title: Doubling posno
Symptoms: To set different posno for brackets, clips and stiffeners, if this objects
have different area or length, there are the variables,
SBH_BRA_AREA_TOL
SBH_STI_LEN_TOL
SBH_CLI_AREA_TOL
that can be set to small values.
There is no such kind of variable for doubling plates?
Previous/Known workaround: N/A
Solution: A new environment variable has been added SBH_DOU_AREA_TOL.
It controles the tolerance of the area comparison for the doubling.
110811 241032 Title: The clip name is disappeared when Cutout > Modify
Symptoms: If clip is defined in CT1 in the Statement Wizard, the clip name will
disappears when Cutout->Modify. There is no problem if clip defined in CT2.
Previous/Known workaround: No known workaround exists.
Solution: Error corrected so that all clip names will appear when modifying a
cutout.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 197 of 517
Product Release Letter
Incident Issue Description
Number Number
112118 244065 Title: Chamfer not correctly handled when refering shell plates with different
thickness
Symptoms: The chamfer handling is not the same for shell plates and planar
plates when refering in boundary statement.
Previous/Known workaround: No known workaround exists.
Solution: It has to do with chamfer rules and that the rules defined in bevel setup
is not used. The rules are defined in the VARIANT statement of bevel setup.
This is now handled by simulating a bevel type 10.
To not disturb on-going project, this must be activated by defining the variable
SBH_BOU_CHAMFER_IN_SHELL_PLATES in the D065-file. The variable can
have any value.

Curved Hull:

Incident Issue Description


Number Number
236301 Title: Error 1023 signalled on creating a shell profile parallel to shell curve
Symptoms: Error 1023 signalled when creating profile by setting the variables
SBH_ENABLE_SOLID_PLATES and SBH_ENABLE_SHPLACOMP to YES
Previous/Known workaround: No known workaround exists.
Solution: This happens when a shell profile is defined by a 3D curve and not a
plane curve. The problem has been solved so that it is possible to create a 3D
shell profile when SBH_ENABLE_SOLID_PLATES is set.
243418 Title: Unable to Import XML of Seam created using general cylinder due to
improper angle values
Symptoms: When exporting a seam created by General Cylinder, the angle
values are wrong. It is presented as '********'.
Previous/Known workaround: No known workaround exists.
Solution: This happens when the angles are undefined and should not be
presented in the XML output file
The problem has been solved so that the angles are put correctly.

Space Management:

Incident Issue Description


Number Number
100305 214979 Title: Void State does not work as described in the User Guide
Symptoms: The User Guide states: "... spaces will not be displayed or take part
in any calculations or operations."
SPMSFP does not conform to this statement.
Previous/Known workaround: No known workaround exists.
Solution: Pseudo attribute is updated to consider void state as well.

Hull Structural Design:

Incident Issue Description


Number Number
109940 239510 Title: Error after Block Division
Symptoms: The ident statement (first line in schema) for a newly split panel still
holds the name of the original panel.
Previous/Known workaround: Manually change the text in the schema
Solution: The first line of the scheme now has the panel name after dividing
panels.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 198 of 517
Product Release Letter
Incident Issue Description
Number Number
241008 Title: Pillar with profile type 60 is taken into idealization even if we meant to
ignore it based on criteria on profile area.
Symptoms: See Title
Previous/Known workaround: No known workaround exists.
Solution: Profile type 60 is now handled in idealisation.

Hull Production:

Incident Issue Description


Number Number
69786 139456 Title: Stiff Marking info of "Main Panel" and "Sub Panel" is duplicate in Gen.File.
Symptoms: Stiffener Marking info of "Main Panel" and "Sub Panel" is duplicate
in Gen.File. There is no need marking info on sub panel.
Known workaround: No known workaround exists.
Solution: Marking info for abutting stiffeners on subpanels will not be created any
more.
82929 176340 Title: Enhancement to Part name on bendingtemplate table
Symptoms: No ship side information included in the Part Name in the template
table.
Previous/Known workaround: N/A
Solution: Ship side information is added to the part name in the template list.
86135 183803 Title: Failure to Bevel of holes on the knuckle panel.
Symptoms: When you run PPI and Interface to a knuckle panel that has a hole
with bevel, the bevel information of the hole is not correct.
Previous/Known workaround: No known workaround exists.
Solution: Planar panel parts generation corrected so that bevel information of
knuckled panel holes will be correct.
103179 221626 Title: Rotation of profile holes
Symptoms: There is a problem with rotation of profile holes, presented in
Manstiff and/or in profile sketches for starboard profiles. Even though model
holes are no rotated, in manstiff and/or in sketches, holes are rotated with 180
degrees.
Previous/Known workaround: No known workaround exists.
Solution: Inclination of holes in profiles corrected. in manstiff and profiles
sketches.
108519 233444 Title: The GSD of Flange is not match to the GSD of Plate on SB-Side.
Symptoms: When the flange is short ( length less than FLA_LIM) then there
should be a GSD marking only at one end. When the flange is a starboard part,
the GSD is at the wrong end.
Previous/Known workaround: No known workaround exists.
Solution: The GSD marking distances corrected for short flanges on SB side.
109903 238281 Title: Mismatch between design and production part names for over centerline
panels.
Symptoms: There are in some cases a differance between the partnames in
design and production for parts across the center line.
Previous/Known workaround: No known workaround exists.
Solution: Partname symmetry code for plate parts corrected.
111230 242027 Title: HULL MARK does not expand in Knuckle Panel.
Symptoms: Projection of a Hull Mark on a sub-panel is not showing any
markings on the resulting plate part.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so sub-panels of a knuckled panel is handled.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 199 of 517
Product Release Letter
Incident Issue Description
Number Number
107158 230927 Title: Ignored quality material for BPANEL (default 'A')
Symptoms: No matter what grade is defined on a bent plate, the default grade A
will be used on the production part.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the defined grade will be transfered to the production
part.

Hull Nesting:

Incident Issue Description


Number Number
104110 223417 Title: Labelling text Pos no ‘Automatic’ doesn't work for specific nest
Symptoms: Labelling text Pos no ‘Automatic’ ends up with same error number
2532.
Previous/Known workaround: Add pos. no. labels manually
Solution: Automatic Pos no corrected to work as expected.
106078 227950 Title: Batch autonest addin do not work with MAX_CONTOUR=-1 in
sbh_nest_def2
Symptoms: Run a nesting batch job where the default MAX_CONTOUR is set to
-1 will end up in an error 1002.
Previous/Known workaround: Define positive a value for MAX_CONTOUR.
Solution: Correction for MAX_CONTOUR = -1 has been done in autonesting.
108838 235622 Title: We can't get plates with another quality in parts menu.
Symptoms: When creating the parts menu in Nesting, the qualities in quality
exhange is not recognised.
Previous/Known workaround: No known workaround.
Solution: Correction for quality exchange have been made.
110739 240943 Title: Nesting, label bevel, degree sign shows up twice on different locations
Symptoms: The Label Shows up as e.g. DS 5° but for each labelled text and
extra o (degree) is shown in the nesting and also labelled when Setting starts for
Labels all.
Previous/Known workaround: Manually remove the extra degree mark.
Solution: Corrected so only one degree sign will be shown and labelled.

Hull Weld Planning:

Incident Issue Description


Number Number
109964 238577 Title: Weld Planning Batch
Symptoms: Missing welds in batch compared to interactive function.
Previous/Known workaround: Use Interactive function.
Solution: Corrected so detected welds in batch is the same as for interactive
function.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 200 of 517
Product Release Letter
Marine Drafting:

Incident Issue Description


Number Number
237131 Title: Newly created shell Plates are dislocated when we change the projection of
the view.
Symptoms: When a new Shell Plate is created and the view is changed for
another projection, the newly created Shell Plate is not projected in the new
projection.
Previous/Known workaround: This is a temporary plate that is presented.
Remove the temporary plate from the view and insert the plate from the model.
Solution: Temporary objects like developed shell plates will be handled correctly
when changing the view projection.
110713 240834 Title: Problem for the unselected elements to be copied while regroup
Symptoms: Regroup subpicture by indicating geometry, sometimes regroups
more than just selected geometry.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so only indicated geometry is regrouped.
243163 Title: Symbolic view properties for a curved panel are not displayed.
Symptoms: Symbolic view properties (Plate names and symbols) for a curved
panel are not displayed in Curved Panel Views.
Previous/Known workaround: Make the views in Hull application.
Solution: Part names and symbols now displayed in the curved panel view.

Engineering:

Incident Issue Description


Number Number
65930 124421 View Item on Diagram doesn't work if ENGITE with same name as SCDIAG is
found first.

Multi-Discipline Supports (MDS):

Incident Issue Description


Number Number
97833 209730 Bad weight calculation (duplicated SCTNs) in MDS Drawing for SBFR elements -
> with enclosed FIX.

Mechanical Equipment Interface (MEI):

Incident Issue Description


Number Number
101796 218396 Title: Curved Panels and Plates in MEI export " _R "suffix
Symptoms: Curved Panels and Plates in MEI export " has Always "_R "suffix for
symmetrical panels. It is important especially for FE Idealized model can be used
further with mapped attributes file in a 3rd party FEA system.
Previous/Known workaround: No known workaround exists.
Solution: Setting name attributes on the geometry for symmetric curved plates
has been solved.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 201 of 517
Product Release Letter
Incident Issue Description
Number Number
110401 240211 Title: Curved Panels and Plates in MEI export " _R "suffix
Symptoms: Curved Panels and Plates in MEI export " has Always "_R "suffix for
symmetrical panels.
It is important especially for FE Idealized model can be used further with mapped
attributes file in a 3rd party FEA system.
Previous/Known workaround: No known workaround exists.
Solution: Setting name attributes on the geometry for symmetric curved plates
has been solved.
112035 244026 Title: Review crash for imported equipment (GENPRIs)
Symptoms: Crash when exporting some equipment (GENPRIs) on review.
Previous/Known workaround: No known workaround exists.
Solution: The error is due to a memory leek which is now handled correctly.

Outfitting:

Incident Issue Description


Number Number
49975 Title: Draw - When an AB ADP drawing is updated, the drawing date is set to that
of the template
Symptoms: Wrong date on newly created drawing
Known workaround: Manual reset date
Solution: Creation date preserved and re-instated after template data copied.
64254 Title: Draw - An error message is displayed on entering the 'PL' in Tag in the
Vertical field in Elevation Tag Defaults window (caused by improperly nested
quotes)
Symptoms:
Known workaround: None
Solution: Corrected the syntax in the form.
69054 137608 Title: Spooler - SHIPCO ON not possible for Spooler
Symptoms: For Spooler in Marine environment the command SHIPCO ON
doesn't work, the system keeps the default value OFF.
Known workaround: None
Solution: The possibility to use customised ship coordinates via the command
SHIPCO ON has been enabled in Spooler in Marine environment.
94343 201736 Title: Piping - Improved handling of reducing couplings on the pipe component
creation form
Symptoms: Set of valid components available for selection was incorrect
Previous/Known workaround: Command line selection
Solution: Fix initialisation and update of reducing component bore filter and
selection list.
97370 208904 Title: Isodraft - Spec Break not shown for closed loop.
Symptoms: Spec Break not shown.
Previous/Known workaround: None.
Solution: Check for Spec Break at closed loop.
106201 228326 Title: PIPE ROUTE - Clash not warned
Symptoms: PIPE ROUTE - Clash not warned
Previous/Known workaround: Route branches invididually
Solution: Ensure messages are not lost.
108375 233106 Title: Isodraft - Erection material partnumbers missing on isometric
Symptoms: Erection material partnumbers missing on isometric
Previous/Known workaround: None
Solution: Do not set the spool numbers on Erection Items if per spool and when
the material list gets too long and breaks to a second page, correct the format.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 202 of 517
Product Release Letter
Incident Issue Description
Number Number
109912 241476 Title: Spooler - SHIPCO ON not possible for Spooler
Symptoms: For Spooler in Marine environment the command SHIPCO ON
doesn't work, the system keeps the default value OFF.
Known workaround: None
Solution: The possibility to use customised ship coordinates via the command
SHIPCO ON has been enabled in Spooler in Marine environment.

12.1.SP4.41

Planar Hull:

Incident Issue Description


Number Number
79544, 168594, Title: CURR_BLOCK default not working when LT object is set
72252, 147169, Symptoms: When keyword CURR_BLOCK is activated the customisation of line
99711, 213761, types with SVIEW_LT_COL object are not working.
100392, 215145, Previous/Known workaround: No known workaround exists.
105740 227105 Solution: This is now corrected so when the customization of the symbolic views
are activated, also the blocks that is outside the CURR_BLOCK selection is
handled as defined in the documentation i.e. all components are all drawn with
green dashed-dotted lines. The selected blocks are drawn with the customised
setup.
103063, 221179, Title: Unwanted reference to RSO - stiffeners
103064 221180 Symptoms: When creating stiffeners, the user selects intersecting stiffeners
belonging to an adjacent panel. In the case were the adjacent panel is located by
an RSO, the chosen panel name is ignored in favor of using the RSO reference.
Previous/Known workaround: Manually change to the panel name.
Solution: If the picked stiffener belongs to a panel that is noted as a boundary
limit, the panel name will be used. RSO name will onl be used if it is a part of the
boundary.
111442 242432 Title: Free Text information disappears on Hull Editor.
Symptoms: If Free Marking Text has been addd in versions prior to SP4 Fix 40,
they will not be possible to handle in SP4 Fix 40 in either schema editor or
statement wizard..
Previous/Known workaround: No known workaround exists.
Solution: Corrected so marking text will be handled in both schema and wizard.
106432 228735 Title: Stiffener same as – quality and other parameters not read correctly
Symptoms: When creating a new stiffener, selecting it as “same as” allows to
read properties of an already existing stiffener and to fill the wizard menu with
this information. Information of the stiffeners quality, end cut parameter of end
cut 2 and bevel info are not read correctly, when doing so.
Previous/Known workaround: Manually fill in the correct parameters.
Solution: Quality and endcut parameters will now be read and filled in correctly.
108042 232358 Title: Overlap bracket is intersecting the shell profile.
Symptoms: When making an overlap bracket (syntax 5), the bracket is
intersecting the profile.
Previous/Known workaround: No known workaround exists.
Solution: This happens when the overlap bracket is modeled against a shell
profile that is not twisted. The issue is corrected so also brackets attached to
straight shell profiles wil lbe correctly placed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 203 of 517
Product Release Letter
Incident Issue Description
Number Number
108850 235662 Title: Shell Plate Compensation does not work on STB
Symptoms: A planar panel on SB side is not correctly attached to the shell
plates.
Previous/Known workaround: No known workaround exists.
Solution: Planar panels defined on SB side and that is not defined in any
principal plane will get a wrong surface reference if Shell Plate Compensation is
used.
This is now corrected.
To get correct result, the panel boundary must be changed, i.e. at least one
bondary should be modified, save panel and then modify the boundary back to
original.
241622 Title: Interval list for bevel in clips are not correctly turned.
Symptoms: The bevels for a macro clip is not at the correct interval.
Previous/Known workaround: This can happen when a clip is defined in
clockwise direction.
The clip should always be defined in a counter clockwise direction but if it is not,
the system will turn it so the resulting clip will be correct. To avoid that the beels
are in the wrong intervals, the wrongly defined macro should be corrected to
describe the clip in counter clockwise direction.
Solution: The system has been updated tyo also turn the interval list
(INTERVALLIST_2D) in case the clip is defined in the wrong direction.

Curved Hull:

Incident Issue Description


Number Number
106786 229638 Title: When modifying the shell profile, the shell profile number is not fully
displayed on UI.
Symptoms: In the message window, the correct profile name is displayed but in
the form, the profile number is missing.
Previous/Known workaround: Manually fill in the correct number.
Solution: The problem has been solved so that the profile name is fully displayed
in the UI.
107854 231982 Title: Text in shell plate views not positioned correctly, is in wrong plate on SB
Symptoms: Putting PS and SB Shell plates into an ISO view in the drawing and
add Shell plate names via properties, they are on PS, presented inside the Shell
plate, but on SB outside the Shell plate at the boundary to the next plate. In the
middle plate the names overlap.
This is then not readable any more and the SB names also confuse as it is not
clear which plate is meant.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the plate text is positioned
correct for SB side plates.
232648 Title: Application crashes after creating Curved Panel view with 'Show Hole
Cross Mark'
Symptoms: See title
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that cross marks can be used.
108540 233556 Title: Chamfer statement with =99 is incorrect for cplates
Symptoms: When a boundary of a planar panel is refering the surface, there is
no chamfer handling in case of change in plate thickness for shell plates.
Previous/Known workaround: No known workaround exists.
Solution: Chamfer is added to the resulting planar panel boundary curve.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 204 of 517
Product Release Letter
Incident Issue Description
Number Number
108581 234463, Title: The colour of the shell plate turned into a curved panel has changed to
203056 cyan.
Symptoms: Shell plates that belongs to a Curved Panel is not changing colour to
green.
Previous/Known workaround: No known workaround exists.
Solution: Colour of shell plates that belongs to a curved panel will be drawn in
green colour.Not used shell plates willl be drawn in cyan colour.
109656 237757 Title: CHM – XML - Seam on general cylinder – wrong tangent definition
Symptoms: When exporting a seam by a general cylinder to XML the tangent
conditions are written as radiant measures. The value for the tangent condition at
end 2 is wrong. Further there are written two decimals only, resulting in a
significant reduction of accuracy.
Previous/Known workaround: No known workaround exists.
Solution: The tangent values has been corrected and the tangent conditions are
written with 6 decimals in the XML output file.
109658 237759 Title: Modify seam on general cylinder – tangent definitions not read
Symptoms: When creating a seam by a general cylinder it is possible to control
the tangent conditions of both end points of directrix. But the definition of tangent
conditions is not read from model and not shown in definition form when trying to
modify a seam defined by a general cylinder.
Previous/Known workaround: No known workaround exists
Solution: The tangent conditions are now read and shown in the definition form
when modifying the cylinder curve.
109660 237777 Title: Seam on general cylinder – second tangent wrongly interpreted
Symptoms: When creating a seam by a general cylinder it is possible to control
the tangent conditions of both end points of directrix. The definition of a tangent
condition at end 2 of direcrix is wrongly interpreted.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the tangent values are correctly
interpreted.

Space Management:

Incident Issue Description


Number Number
110044 239761 Title: Can not create SPMSPC element and generate Blocks in Hull Space
Management
Symptoms: When trying to automatically create blocks from the space
arrangement, the system aborts.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the blocks are created as expected.

Hull Production:

Incident Issue Description


Number Number
120154 Title: Bending Template: Cancel/Quit/[X] functions as OK button
Symptoms: Bending Templateapplication runs even if Cancel or Quit button is
clicked.
Known workaround: No known workaround exists.
Solution: The bug is now fixed and the Cancel or Quit button works as expected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 205 of 517
Product Release Letter
Incident Issue Description
Number Number
99917 214202 Title: Start mark will bite on the Boundary limit of panel.
Symptoms: Occationally when run ppanparts, there will result is some very small
segments that will later on in production cause some problems. Those segments
are less than 0.001 mm and should be removed.
Previous/Known workaround: No known workaround exists.
Solution: The tolerance for checking small segments has been modified to
remove smaller segments than 0.001 mm.
110003 238588 Title: SBH_BKT_SMALL_TOE_NO_COMP does not work with AutoBevel
Symptoms: In case of Auto Bevel resulting in a bevel, the variable
SBH_BKT_SMALL_TOE_NO_COMP has no effect. The toe is always
compensated.
Previous/Known workaround: Use fixed bevel code.
Solution: Variable SBH_BKT_SMALL_TOE_NO_COMP will also be handling
the case where AutoBevel is used for brackets.

Hull Nesting:

Incident Issue Description


Number Number
102804 220695 Title: System Error 2532! when opening existing nest
Symptoms: Part cause that problem has a bevel defined along CURVE limit.
Designer succeed to create a new nest including that part with all necessary
starts and labels.
In some point during hull modeling he switch the bevel SIDE, along that curve
limit and split again.
As a result, when trying to open the nest holding that part he got an error 2532.
Previous/Known workaround: Delete complete nest and start over again.
Solution: The modified part will be correctly included in the old nesting.
108649 235428 Title: Side info for shell plates is the opposite of what it should be
Symptoms: In Nesting sketch when adding side information, for some shell
plates, the side information is opposit to the actual side.
Previous/Known workaround: No known workaround exists.
Solution: When the side of a shell plate is calculated, the calculation for some
plates went wrong. This is now corrected.

Marine Drafting:

Incident Issue Description


Number Number
93104 199316 Title: The text in labels (general label or symbolic label based on a text template,
TXTM) is now centered vertically in the circumscribed box.
Symptoms: Text in label is not centered in the box
Previous/Known workaround: None
Solution: The system now adjust the position of the text so that it is centered
vertically. In old drawings an update anno can make the label text move down a
small distance.
95813 204725 For a description of this enhancement see section Enhancements above.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 206 of 517
Product Release Letter
Incident Issue Description
Number Number
95633 207454 Title: DENY_UPDATE_OF_NON_PERSISTED_GEOM=YES has now effect for
SLABs
Symptoms: DENY_UPDATE_OF_NON_PERSISTED_GEOM=YES will not allow
you to edit the intelligent text
Previous/Known workaround: None
Solution: In general DENY_UPDATE_OF_NON_PERSISTED_GEOM=YES has
no effect for SLABs and this is by design. An exception is when the SLAB referes
to a TXTM where the BTEXT attribute has the value "#ATEX". The system will
now allow to edit the "ATEX" attribute of the SLAB.
In addition, when DENY_UPDATE_OF_NON_PERSISTED_GEOM=YES and
editing the text in a SLAB is not possible there is now an error message "The
label text cannot be modified since it originates from a label template".
104183 223728 Title: Insert Subpicture Error
Symptoms: save General subpicture and insert to other Drawing,
Dimmension compoenents are on wrong position.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the dimensions will stay at their positions.
106049 227866 Title: Problem not to restore the removed area of graphics from a drawing by
blanking.
Symptoms: When hide the layers to contain the Glab or Slab, the removed area
of graphics from a drawing by blanking was not restored
Previous/Known workaround: No known workaround exists.
Solution: When hiding Labels and Dimension layers, the removed blanking area
will now be restored.

Schematic 3D Integrator:

Inciden Issue Description


t Number
Number
108523 233455 Title: SVG: Open more then 20 diagrams at the same time.
Symptoms: not able to open more than 20 diagrams
Previous/Known workaround:
Solution: Now user can keep maximum of 50 diagrams open at a time.

Multi-Discipline Supports (MDS):

Incident Issue Description


Number Number
91135 197120 Title: Error Creating Lisega Spring Supports
Symptoms: In certain configurations it was not possible to create a Lisega
Spring support because the steel elevation was being sent as the same as the
pipe elevation to LICAD.
Previous/Known workaround: None
Solution: The steel elevation is now being sent to LICAD as the pipe elevation
minus half the outside diameter of the pipe.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 207 of 517
Product Release Letter
Pipe Fabrication:

Incident Issue Description


Number Number
109175 236500 Title: Pipe Fabrication, Multiple Spools: spool limit may be set, but not reset
Symptoms: It is possible to add certain spool limits, but not remove them
Previous/Known workaround: Update the ASFBREAK/LSFBREAK attributes
manually to remove the spool break
Solution: There was a bug where if the components selected belong to the same
branch we checked the CSFBREAK attribute to determine if a spool break
already existed. Instead we should have been checking the LSFBREAK of one of
the two components selected dependent on if the spoolbreak is being.

Outfitting:

Incident Issue Description


Number Number
40878 69561 Title: Isodraft - question about cap in iso
Symptoms: Cap shows a weld on the closed end.
Known workaround: Add dummy continuation.at end of pipeline.
Solution: If at item code/description section, do not forget to set end flag after a
cap.
89020 191124 Title: ISODRAFT Refarence Dimension cause incorrect MTO
Symptoms: ISODRAFT RefarenceDimension cause incorrect MTO
Previous/Known workaround: Add dummy continuation.at end of pipeline
Solution: If at the start of the Item Code/Description section - do not attempt to
look further along the pipeline.
100383 215104 Title: Isodraft - In specific configuration, the cutting list is missing from isometric
Symptoms: In specific configurations (e.g. Elbow-Mitred Bend-Elbow where the
LPOS of one is at the APOS of the other), the cutting list is missing from
isometric.
Previous/Known workaround: iItroduce a gap of 1.1mm
Solution: Now fixed.
103949 223180 Title: Spooler - Spool Break errors when Coupling connected to Branch leave
tube or Mitred Bend
Symptoms: Errors in Create Spool Break PL and single component SPOOL
created for Coupling.
Previous/Known workaround: None.
Solution: Don't create new SPOOL at Branch leave tube and allow spool breaks
to be set for a Mitred Bend.
105008 225374 Title: Cable - Unable to edit CWBRAN route points with Model Editor.
105458 226549 Title: Reporting: Data source error in report designer.
231407 Title: Isodraft - Incorrect Support part number in isometrics.
Symptoms: Support part numbers appear as '0'
Previous/Known workaround: None
Solution: Add on number of Material list attribute value records when calculating
position of Tag Number.
231960 Title: Isodraft - Bend information truncated in isometrics when use
HYPERPLANT ON
Symptoms: Bend information truncated in isometrics when use HYPERPLANT
ON
Previous/Known workaround: None
Solution: Shuffle buffer correctly.
108726 235448 Title: PADD has been corrupted and any actions cannot be done for recovery.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 208 of 517
Product Release Letter
Incident Issue Description
Number Number
236009 Title: Isodraft - When DIM ALL : ON & ATTEXT 288 : OFF, Atta dimension was
wrongly generated in isometrics
Symptoms: When DIM ALL : ON & ATTEXT 288 : OFF, Atta dimension was
wrongly generated in isometrics
Previous/Known workaround: None
Solution: Suppress specification change if required.
109743 238020 Title: Structures - Marine add-on toolbar functions copy and include FIXING
elements
Symptoms: FIXING owning FIXING instead of being siblings in the DB hierarchy
Previous/Known workaround: Copy fixings separately, one at a time
Solution: Correct DB location selected for copied FIXINGS.

12.1.SP4.40

Assembly Planning:

Incident Issue Description


Number Number
95620 204374 Title: When the Robot control file of Ass.Tree that contain KN-Panel is created,
Fatal Error occurs.
Symptoms: System aborts when a kniuckled panel is included in the assembly
where the Robot controlfile is created.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the file is produced as expected also when knuckled
panels are involved in the assembly.

Planar Hull:

Incident Issue Description


Number Number
41584 66587 Title: SWAGE display error
Symptoms: Problem displaying a planar panel with defined swaging in 3D.
Previous/Known workaround: No known workaround exists.
Solution: Modifications have been done to enhance the display of swage panels.
77310 161215 Title: Colour Settings for Marking Free text.
Symptoms: Enhancement to be able to set colour on markings.
Previous/Known workaround: No known workaround exists.
Solution: It is now possible to set a colour for a Free text marking. This is done
inthe same way as for other hull components with the keyword COL.
If no colour is set by the user, the colour will be set by the system as before.
84188 186642 Title: Flange endcut
Symptoms: For curved flanges, if the endcut angle is more than 90 degrees, it is
not presented in any views.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved for endcuts in curved flanges with angle
bigger than 90 degrees.
91459 196592 Title: If you add Bevel side by input scheme, Bevel side id changed to automatic.
Symptoms: If one of the bevels are set as -251 on a bracket, then the bevel side
is not changes from PS to SB. If then set back to positive, it is still not changed. It
happens only if bevels are set to positive and side to SB.
Previous/Known workaround: No known workaround exists.
Solution: The bevel side given in the scheme will be kept and will not be
changed by the system.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 209 of 517
Product Release Letter
Incident Issue Description
Number Number
95370 203755 Title: Differences of the panel shape in the Shell Stiffener Section view and Web
Plan view.
Symptoms: In a section view of a shell profile where a non varying bevel type is
choosen by the system, the foot point of the profile is adjusted. This will show a
wrong picture of the profiles.
Previous/Known workaround: No known workaround exists.
Solution: This is now corrected. Basic problem is that the section view of the
shell stiffener is moved as if the variable SBH_PROFPT_ADJUST was defined
(which it is not in this project).
Views must be recreated.
If a bevel of a non varying type is choosen due to the varying conditions, the
variable SBH_PROFPT_ADJUST can be used if needed.
101894 218556 Title: BPANEL split is not possible
Symptoms: Not possible to nest parts originating from tn outfitting bent panel.
Error 2509 is given by the system.
Previous/Known workaround: When creating the parts, use Right Mous Button
to create the parts.
Solution: The error has been corrected. The BPANEL parts have to be re-
created.
102272 219334 Title: Auto-Cutout for SB Shell Profiles fails
Symptoms: when using Auto Cutout in a over CL panel, the cutouts are
duplicated.
Previous/Known workaround: Manually remove the duplicates in the schema.
Solution: Corrected so there is no double statement for the cutouts.
105920 227848 Title: Endcut 10400 is wrong in SP4
Symptoms: Endcut code 10400 is wrong presented in 3d views.
Previous/Known workaround: No known workaround exists.
Solution: The display of endcut 10400 is corrected.
The issue with this endcut was introduced in 12.1.SP4 Fix 35 but are only
affecting the 3D display. Production part is not affected.
107133 230236 Title: Fillet curve is not using mould surface
Symptoms: Fillet Curves in Planar Hull parallel to the surface is not using the
mould surface as the reference.
Previous/Known workaround: No known workaround exists.
Solution: The original intention is that fillet curve and topological point
intersecting with the surface, should always use the mould surface.
This is now corrected so mould surface is always used in those two cases.

Curved Hull:

Incident Issue Description


Number Number
83398 177590 Title: Multi User Usage For Curved Hull.
Symptoms: When a user tries to do recreate of an Curved Panel and any of its
parts are locked by another user, there are no inbdictaions to the user that
someone else is working with a part in the panel.
Previous/Known workaround: No known workaround exists.
Solution: When a Curved Panel is modified or recreated there is a check if parts
belonging to the panel are claimed by other users and the program will give
messages about what parts are claimed by other the users in the message
window.
100832 216513 Title: Problems to define fillet surface with R1 smaller R2
Symptoms: A fillet surface cannot be created with R1<R2 if a certain length of
the surface is exceeded.
Previous/Known workaround: No known workaround exists.
Solution: The filletting function has been corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 210 of 517
Product Release Letter
Incident Issue Description
Number Number
102467 219896 Title: Seams with 5-digt numbers can be created when modifying existing seams
Symptoms: It is not possible to create seam with higher number than 9999 but it
is possible to rename the seam afterward to a higher number.
Previous/Known workaround: No known workaround.
Solution: Seam names with a number above 9999 is prevented also when
modifying the seam.
103459 222055 Title: Shellx view needs option to hide ceam names.
Symptoms: -----
Previous/Known workaround: -----
Solution: A new default keyword, SHX_NO_SEAMNO is introduced. By setting
this keyword in Curved Hull, the seam numbers in Shell Expansion Views will be
hidden.
103775 222724 Title: Problem not to create an XML file containing Hull Steel data for the curved
panel
Symptoms: When create an XML file containing Hull Steel data for the curved
panel by Hull Steel Export, the error "Segment part does not exist" occur.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that it is possible to create XML Steel
data. There was a correction due to the free naming project.
104665 224868 Title: There are no identification information in GEN.file for HULL-MARK marking
Symptoms: A Hullmark is on a planar plate marked as HULL_MARK in the
generic file for the keyword MARKING_TYPE. For shell plates, this attribute is
empty.
Previous/Known workaround: No known workaround exists.
Solution: Hullmarks are now getting the correct type in the generic file for the
shell plates.
MARKING_TYPE=HULL_MARK
105592 226753 Title: Curved Panel View shows wrong traces of planar panels
Symptoms: A Curved Panel View shows traces of planar plates, even if these
planar plates do not have any connection or reference to the specific surface.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that only panel curves with reference
to the Curved Panel surface are drawn.
105741 227116 Title: MarHullVerify doesn't know about RSO as splitting object for shell stiffener
Symptoms: When using MarHullVerify and a Shell Stiffener is split against an
RSO, the verification reports an error that the splitting object is missing.
Previous/Known workaround: No known workaround exists.
Solution: When verifying shell Stiffener ends, RSO was not checked. This check
is now added.
106500 228900 Title: SBH_SHSTI_DEF_CON does not apply when splitting the shell profile by
plane panel.
Symptoms: SBH_SHSTI_DEF_CON does not apply when splitting the shell profile
by Plane Panel or RSO or Shell Profile.
Previous/Known workaround: Connection codes can be modified in Shell
Stiffener form.
Solution: The original implementation of the default handling was intentional. Not
all connection types are valid for all types of connections.
However, it is now implemented so SBH_SHSTI_DEF_CON is used for all five
connections valid in Split Shell Stiffener.
There might then be error signaled from the system that the wrong connection
type is used. This can be avoided by setting the environment variable
SBH_CONNCODE_NOCHECK to any value. This will then override the check
and the shell stiffeners will be updated. User may have to modify the stiffener
connection manually afterwords.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 211 of 517
Product Release Letter
Incident Issue Description
Number Number
229455 Title: Curved Hull Surface create Fillet fails
Symptoms: Not possible to create a Fillet Surface via CHM
Previous/Known workaround: No known workaround exists.
Solution: The filletting function has been corrected.
Also the surface normals are now pointing in the same direction for the whole
surface.
107443 230976 Title: StiffenerCombine method does not work
Symptoms: The methode kcs_chm.stiffener_combine in .net and Vitesse does not
work. It aborts the system.
Previous/Known workaround: No known workaround exists.
Solution: Problem is resolved.

Hull Structural Design:

Incident Issue Description


Number Number
232485 Title: There is no way to discard the panel selection in block division once panel
is selected graphically.
Symptoms: After the panels have been selected, the functions Operation
Complete, Reject, Quit is dimmed out. Only way forward is to hit Enter key.
Previous/Known workaround: Hit Enter key and continue.
Solution: Buttons for Quit, Cancel, Operation complete, Options and All are now
enabled also when picking from the Select dialog via Block Division.

Hull Production:

Incident Issue Description


Number Number
182949 Title: Multiple issues with panel having single boundary limit.
Symptoms: Application crashes for updating seam of any type
Previous/Known workaround: No known workaround exits.
Solution: Now possible to modify seam and boundary in one-limit boundary
panel.
94235 201263 Title: Auto Bevel at clip has a problem
Symptoms: The bevel on clip side attached to the mould side of a profile is not
correct. This is in the macro defined and interval type 10.
This is an issue introduced in 12.1.SP4 Fix 26.
Previous/Known workaround: No known workaround exists.
Solution: Issue is fixed so the bevel on the clip attached to the mould side of the
profile is correct.
This affects bevel interval type 10 and 11.
10 Profile web (mould side)
11 Profile web overlapping plate (mould side).

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 212 of 517
Product Release Letter
Incident Issue Description
Number Number
102791 220632 Title: Cutout type 6, /WIDTH option
Symptoms: Radiuses are calculated and drawn correct. Problem is, when we
use REF for gap definition. Example of cutout 999 definition:
CUTOUT, 999
/TYPE=6
/PROF=(40,43)
/ARC=4 /RAD=0.25
/R_MIN=30
/WIDTH
/ARC=6 /REF=4
/GAP=3 /DIST=30
/GAP=4 /REF=6
/GAP=5 /DIST=30;
Radius 4 (and 6 ) are calculated as maximum (0.25*WIDTH, 30) and this is OK .
GAP 4 should be same as radius 6, but system calculate it as RAD + R_MIN.
Previous/Known workaround: No known workaround exists.
Solution: The clearence of the top has been corrected for this case. It will have
the same value ar the refered radius r6.
104856 225122 Title: To create seperate gen file for profiles selected in Profile Sketch and List
Symptoms: Today it is not possible to create seperate gen file for profiles
selected at " Profile Sketch and List" operation.
Previous/Known workaround: -----
Solution: The following new keyword will be recognised in the restriction file
defined by SBH_PROF_RESTRICT:

PGEN_SEPARATE= YES/NO

A separate generic file will be created for each profile selected by Profile Sketch
and List, if this keyword is set to YES. Default value is NO.
104913 225216 Title: INTERVALLIST_2D in geometry macroes are not passed as parameters
between macroes in the CALL statement.
Symptoms: When using a subroutine, the INTERVALLIST_2D is not handled in
the parameter list.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so data in INTERVALLIST_2D is passed correctly between
routines.

Hull Nesting:

Incident Issue Description


Number Number
106507 229011 Title: Error 2532 after starts deletion
Symptoms: After deleting the starts in the nesting, the error 2532 is set by the
system.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that starts can be deleted and correctly defined again
without getting the error 2532.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 213 of 517
Product Release Letter
Marine Drafting:

Incident Issue Description


Number Number
12363 51485 Title: Tools > Inquiry > model
Symptoms: Model Info does not work for Outfitting models.
Previous/Known workaround: No known workaround exists.
Solution: It is now possible to use "Model Info" for outfitting models through the
PML Trigger "trigdraftmodelinfopre.pmlfnc".
For more information see release note.
74888 153704 Title: Shell plates in Shell Expansion View
Symptoms: Enhancement to not include shell plates in the Shell Expansion
View.
Known workaround: No known workaround.
Solution: It is now possible to disable shell plate computations in shellx views by
setting the default value SHX_NO_SHELLPLATES.
82457 177594 Title: Symbol Positioning Function
Symptoms: Symbols can not be positioned automatically when placed using
MarApi.
Previous/Known workaround: Manually calculate correct position and symbol
angles.
Solution: Solved by handling automatic positioning when symbol is created via
MarApi function SymbolNew in the same way as the interactive "insert/symbol"
function. This means that the modal setting for automatic positioning is used
(apply or not, standard distance and maximum distance).
86281 184218 For a description of this enhancement see section Enhancements above.
92754 198718 For a description of this enhancement see section Enhancements above.
96172 205928 For a description of this enhancement see section Enhancements above.
102444 219833 Title: Auto-Cutout for SB Shell Profiles fails
Symptoms: When using Auto Cutout in a over CL panel, the cutouts are
duplicated.
Previous/Known workaround: Manually remove the duplicates in the schema.
Solution: Corrected so there is no double statement for the cutouts.
105426 226427 Title: SWAGE display error
Symptoms: Problem displaying a planar panel with defined swaging in 3D.
Previous/Known workaround: No known workaround exists.
Solution: Modifications has been done to enhance the display of swage.

Engineering:

Incident Issue Description


Number Number
95818 204975 Title: Reporting - AddScope method of PMLReport Object.
Symptoms: Unable to export the Tubi's to excel in the specified scope .
Previous/Known workaround: Including the Current Element in the scope.
Solution: Exposed a new PML method to the user which accepts the include CE
as a parameter which when set to true addresses the current issue .
86193 208269 Title: Reporting: ReportWriter - Modify data source fields
Symptoms: The '>>' button is never enabled.
Previous/Known workaround: NA
Solution: Property which controls enabling or disabling of user control '>>' has
now been set to true for default behavior.
223537 Title: Delete database object not possible to general user when status has invalid
reference.
Solution: Implemented a PML callable method which cleans up the orphan
status links.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 214 of 517
Product Release Letter
Incident Issue Description
Number Number
104089 223923 Title: Compare/Update - Pseudo-attribute doesn't work with the CUB in DESIGN
Symptoms: Unable to compare the attributes without update.
Previous/Known workaround: No known workaround.
Solution: Implemented the feature so that user can now compare the attributes
without an update.

Pipe Stress Interface:

Inciden Issue Description


t Number
Number
107406 230972 Title: PDMS/PSI Pressure Conversion issues
Symptoms: Pressure values in pascals in the CII input file are wrong by several
orders of magnitude.
Previous/Known workaround: No known workaround.
Solution: The issue is fixed and quantities appear correct.

Pipe Fabrication:

Incident Issue Description


Number Number
106051 227878 Title: When generating pipe sketches, on some computers process aborted due
to an error
Symptoms: When generating a pipe sketch for the first time it is possible to get
an error (41,219) Error Cannot access log file.
Previous/Known workaround: This is due to an error in setting the user path so
the workaround is to reset the user path in the options tab.
Solution: The problem was that the PDMSUSER variable was not being set in
some cases. This is now fixed.
107404 231282 Title: Incorrect MTO when OLET & TEE used in the branch
Symptoms: The MTO of iso based pipe sketches sometimes get incorrect part
numbering such that some item numbers are duplicated and some are missing
from the mto.
Previous/Known workaround: This only happens on iso based pipe sketches
so drawing based ones are unaffected.
Solution: The part numbering routine has been improved.

Outfitting:

Incident Issue Description


Number Number
58941, 102016, Title: Cable - Conduit Dreesing
71949 181697 Solution: Circular cable ways now dressed properly.
Conceptual design drawn correctly with cylinders & circular toruses.
Does not create risers.
Risers not required in the catalogue.
Rotated bends are now valid.
78190 163852 Title: Equipment - Update Equipment Design Template
Symptoms: Not previously available.
Previous/Known workaround: Use Design Template Propagate Changes
function.
Solution: New form to update individual Equipment Design templates.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 215 of 517
Product Release Letter
Incident Issue Description
Number Number
95155 205300 Title: Piping - Pipe assemblies in pipes with bending machine constraints
Symptoms: Pipe bending machine settings ignored when creating assemblies.
Previous/Known workaround: Use pipe fabrication functions after pipe
assembly created.
Solution: Pipe bending machine function built into pipe assembly creation.
96170 206083 Title: Piping - QPR handles not moving with the new element.
Symptoms: QPR handles not moving with the new element.
Previous/Known workaround: No known workaround.
Solution: Fixed.
96362 206446 Title: Database and Data Management - Paragon COCOREF Error
Previous/Known workaround: No known workaround.
Solution: It is now possible to have duplicate entries in a COCOREF attribute
e.g.

NEW COCDES /AAZN-COCDES


DESCRIPTION ‘PLAIN’
COCONNECTION AAZN

NEW COCO /AAZN-AAZN


CTYP AAZN AAZN
CKEY FL
COCOREF /AAZN-COCDES /AAZN-COCDES
96600 207236 Title: Database and Data Management - Running Search Utility with SPCOs it is
not possible to change DETREF attribute.
Symptoms: Using Paragon I can do a search for the item A1A/NPA15 and it
finds 3 of them. In the Search results I can add the extra columns to show these
attributes. When I try to change DETREF on the items in the Search Results I get
a message saying Wrong Database Type. When I change the value (to
00NPB0F-D) in the Attribute explorer the field turns red and I get an Invalid value
message. I can change it on the command line but not in either of these.
Previous/Known workaround: None
Solution: Port of the code from Admin 1.5 to 12.1 SP4.
97592 209562 Title: Database and Data Management - RTEX Value Increrased but Reconfigure
Fails
Solution: Reconfigurer has been changed to handle texts which are longer than
defined by the schema but still fit into the database. A warning message is
displayed instead of a failure.
98002 210207 Title: Piping - Reducing Tee in a Pipe Assembly
Symptoms: Error displayed for this component type
Previous/Known workaround: None
Solution: Error handled and Pipe Assembly removed if it cannot be resolved.
98010 210209 Title: Piping - Pipe Assembly with a REDU increasing within the flow
Symptoms: Getting an error when utilizing a Pipe Assembly that contains a
REDUCER
Previous/Known workaround: None.
Solution: Error handled and Pipe Assembly removed if it cannot be resolved.
97701 210295 Title:Piping - PDMS12.1.Sp4 &E3D 2.1 Model (ID@) Does not work with piping
components with repress inul on trans xx
Symptoms: Cannot pick ppoints.
Previous/Known workaround: Turn off insulation
Solution: Now working.
210607 Title: Draft - DXF File doesn’t use correct TTF
Symptoms: Exotic TrueType fonts come out as Arial in DXF
Known workaround: N/A
Solution: Program checks registry for filename of TT font.
This will work only if the TT font is correctly installed on the machine.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 216 of 517
Product Release Letter
Incident Issue Description
Number Number
100321 214981 Title: Piping - Splitting pipe errors
Symptoms:
Previous/Known workaround: No known workaround.
Solution: The command for setting LSTU was not correct. Corrected it.
100531 215502 Title: Spooler - Weld position calculated incorrectly for weldneck Flange.
Symptoms: Weld created in wrong position.
Previous/Known workaround: None
Solution: Calculate weld position from correct P-point of Flange.
215657 Title: Database and Data Mangement - Performance of Reconfigurer and Dice
on very large Databases
Symptoms: Reconfigrer and Dice operations on Very large PADD DBs take a lot
of time and sometimes crashes.
Previous/Known workaround:
Solution:
1- Backporting issue 200982 to allow reconfigurer to complete if strings are
longer than schema length.
2- New fix to avoid Dice crash.
3- Improved Dabacon and Flrayer Performance.
4- Using RamDisk for Reconfiguring large DBs.
Using the RAM disk / RAM Drive software can improve the performance of
Reconfigurer and Dice on very large Databases significantly. (Please note that
the above fixes show the improvement on the performance on large DBs
significantly when REMDRIVE is used.)
102906 221601 Title: Cable - With Circular CWAY, rotated Bend was not Dressed.
Symptoms: See title.
Previous/Known workaround: No known workaround.
Solution: Circular cable ways now dressed properly.
Conceptual design drawn correctly with cylinders & circular toruses.
Does not create risers.
Risers not required in the catalogue.
Rotated bends are now valid.
103639 222384 Title: Isodraft - Isodraft error, system isometrics
Symptoms: Wrong and misleading dimensions on system iso when having a
split atta with a distance from previous component.
Previous/Known workaround: None
Solution: Handle hanger and concurrent weld.
103816 222839 Title: Equipment - Flush fails when an element has changed type and owner
Symptoms: Error (43,419) produced when flushing
Previous/Known workaround: None
Solution: Backported changes from E3D to allow flush when an element has
changed type and owner.
104317 223840 Title: Isodraft - WELD NUMBER SHOWN on DRAWING and in WELD TABLE
not corresponding
Symptoms: WELD NUMBER SHOWN on DRAWING and in WELD TABLE not
corresponding
Previous/Known workaround: None
Solution: For a weld, check if bypass point. If so, use sheet number of next
component. It may be different if there is a sheet break after weld.
104637 224610 Title: Structures - Problem with collect exactly and gtroom with FLOOR elements
Symptoms: FLOOR & other softypes of PANEL not correctly collected with
EXACTLY function.
Previous/Known workaround: None
Solution: Now working.
104725 224862 Title: Isodraft - Wrong item number in isometric drawing
Symptoms: Wrong item number in isometric drawing
Previous/Known workaround: None
Solution: Check if tee is a null/empty tee before the reducer.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 217 of 517
Product Release Letter
Incident Issue Description
Number Number
104936 225275 Title: Piping - Why is the LQCON value reporting FALSE?
Symptoms: LQCON can give wrong value for BRAN.
Previous/Known workaround: None.
Solution: Fixed.
105517 226678 Title: Structures - Hole management for Section penetrations with unset GTYP
Symptoms: Incorrect hole size for SCTN/GENSEC with unset GTYP.
Previous/Known workaround: Set the GTYP appropriately.
Solution: Get GTYP from catalogue if not set on the element itself.
105874 227468 Title: Structures - Hole management system recognises tube (circular cross-
section) profiles
Symptoms: Circular section is given rectangular hole parameters. The hole
shape can be set to circular, but the minimum diameter of the hole is constrained
by the rectangle parameters, so a true minimum diameter cannot be achieved.
Previous/Known workaround: None
Solution: Recognise Sections with circular cross-section.
105877 227474 Title: Structures - Correct GENSEC GTYP after fillet operation
Symptoms: GTYP of GENSEC left unset after Fillet operation
Previous/Known workaround: Set appropriate GTYP after fillet
Solution: GTYP is copied from the first picked SCTN element and applied to the
resulting GENSEC.
105498 227507 Title: Isodraft notes and dimensions
Symptoms: When using Truetype fonts, there are big gaps from the text to the
start of the leader line and the dimension text is also not centred and large gaps
appear as well.
Previous/Known workaround: None
Solution: Calculate text width correctly for Truetype Fonts.
102123 228237 Title: Isodraft - Isometric fails with error 'One leg of CROSS ... is connected to
BRANCH ... but the positions are not the same'.
Symptoms: One leg of CROSS ... is connected to BRANCH ... but the positions
are not the same.
Previous/Known workaround: None.
Solution: Use correct transformation matrix for SITE position.
229824 Title: Piping - Validity of the PTOD attribute for TRUNNI
Symptoms: PTOD & PHOD not work correctly for TRUNNI
Previous/Known workaround: None
Solution: Now fixed.

12.1.SP4.37

Planar Hull:

Incident Issue Description


Number Number
89008 190601 Title: Cutout/Clip form error
Symptoms: When adding cutouts that have been defined as "Named Cutouts",
the Clip Data tab of the form is not blanked correctly when switching cutout/clip
types.
Previous/Known workaround: No known workaround exists since some fields
may be blocked by the system.
Solution: Corrected so that the form will adapt correctly when cutout type is
changed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 218 of 517
Product Release Letter
Incident Issue Description
Number Number
101629 217950 Title: Splitted knu panel has gone from DB after Clean workspace.
Symptoms: After splitting a knuckled panel back to ordinary panels, the panels
are not availabel for input if Clean Workspace has been performed.
Previous/Known workaround: Do "Apply" (or Apply and Deactivate) right after
the knuckled panel has been splitted up.
Solution: Corrected so the resulting panels will be available.
101975 218663 Title: PosNo from BKT-Instance written in scheme for group of BKTs
Symptoms: If more than one bracket is defined in a statement, using a bracket
instance with a defined position number, the number is always written to the
statement.
Previous/Known workaround: Either leave it as it is or manualy remove it from
the statement.
Solution: Corrected so the position number will not be written in the statement as
long as it is the same as in the instance definition.
101983 218771 Title: Clip definition disappears when modifying cutout/clip statement
Symptoms: When adding Clips to the cutout and modifying the clip in
StatementWizard, the clip is removed from the statement.
Previous/Known workaround: Manually add it again or use the schema editor
to modify cutouts.
Solution: Corrected so the clip will remain in the wizard.
102082 218940 Title: New stiffener issue, endcut angle
Symptoms: The endcut angle for end 2 in the stiffener is wrong.
Previous/Known workaround: This is related to the default keyword
KNUCKLED_STIFFENER and is defined to TWISTED. If set to KNUCKLED or
>NOT SET>, the angles are correct.
Solution: This is now corrected so the endcut angle is as expected also when
TWISTED is defined.
102178 219286 Title: Not possible to get "SURPNT"/"SURNOR" value for some cases.
Symptoms: In some cases the attribute SURPNT/SURNOR is failing.
Previous/Known workaround: No known workaround exists.
Solution: The attribute fails as soon as the connection vector is not parallel with
the normal vector of the planar (sub) panel. This check is removed as it has no
meaning. The resulting point is verified that it is inside the panel.

Curved Hull:

Incident Issue Description


Number Number
58108 98725 Title: Shell plate offset from a surface
Symptoms: Not possible to create a shell plate with an offset from the surface
like thickness 10 on inside and -5 on outside.
Known workaround: No known workaround exists.
Solution: Shell Plate form is modified to acceppt also plates defined with an
offset from the surface, e.g. defining thickness as 10 mm inside and -5 outside.
80264 171004 Title: Curved Panel Symbolis View for reflected shell panel
Symptoms: When attemtping to create a Curved Panel Symbolic View from the
stbd panel of SBP shell, there is no option to create the view specifically for the
stbd panel. Selecting the stbd panel results in a port side Curved Panel view.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that it is possible to make side
specific
Curved Panel View for symmetric panels. The reflection should
be indicated in the selection form.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 219 of 517
Product Release Letter
Incident Issue Description
Number Number
80041 175819 Title: Curved Panel Symbolis View for reflected shell panel
Symptoms: When attemtping to create a Curved Panel Symbolic View from the
stbd panel of SBP shell, there is no option to create the view specifically for the
stbd panel. Selecting the stbd panel results in a port side Curved Panel view.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that it is possible to make side
specific
Curved Panel View for symmetric panels. The reflection should
be indicated in the selection form.
86043 183547 Title: Shell profiles marking line will not match with Frame ruler.
Symptoms: Adding marking on shell stiffeneres at a frame position, the marking
is not exactly at the frame position.
Previous/Known workaround: No known workaround exists.
Solution: The frame marking is corrected to be exactly at the frame position.
92608 198564 Title: ShellX over CL, Endcut symbols of Cstiffs point to the wrong direction
Symptoms: ShellX over CL, Endcut symbols of Cstiffs point to the wrong
direction after Model View Exchange or Model Modify
Previous/Known workaround: No known workaround exists
Solution: The problem has been solved so that the endcut symbols points in the
right direction.
93898 200630 Title: Problems running XML input for SB-specific Shell Profiles
Symptoms: When importing an XML file containing an SB shell profile, the
referred objects are not handled correctly and the import fails.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the intersection with reflected models will be correctly
handled in Export/Import of curved hull XML. Already exported objects must be
exported once more.
94961 202932 Title: Curved Panel Symbolis View for reflected shell panel
Symptoms: When attemtping to create a Curved Panel Symbolic View from the
stbd panel of SBP shell, there is no option to create the view specifically for the
stbd panel. Selecting the stbd panel results in a port side Curved Panel view.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that it is possible to make side
specific
Curved Panel View for symmetric panels. The reflection should
be indicated in the selection form.
97871 210248 Title: Error 380 after modifying symmetry of Cstiffs from “SB” to “PS and SB”
Symptoms: When a symmetrically defined Cprof contains one Cstiff with
symmetry code SB only, Error 380 occurs when interactivels modifying symmetry
from "SB" to "PS and SB".
Previous/Known workaround: No known workaround exists.
Solution: The problems has been solved when modifying from “SB” to “PS and
SB”.
101898 218557 Title: ShellX over CL - Cseam over CL after modification updated on PS only
Symptoms: In a ShellX over CL a transverse seam over CL is updated on PS
only after being modified.
Previous/Known workaround: Additional recreate required to update view
correctly.
Solution: The problem has been solved so that the seam is updated on both
sides when it has been modified.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 220 of 517
Product Release Letter
Incident Issue Description
Number Number
102447 219841 Title: Problems running XML input for SB-specific Shell Profiles
Symptoms: When importing an XML file containing an SB shell profile, the
referred objects are not handled correctly and the import fails.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the intersection with reflected models will be correctly
handled in Export/Import of curved hull XML. Already exported objects must be
exported once more.
102857 220748 Title: Profile Sketch and List - Wrong position of holes and notches
Symptoms: Profile Sketch and List with bending method M1 delivers wrong
positions for holes and notches.
Previous/Known workaround: No known workaround exists.
Solution: Marking distances corrected so that overlength and compensation are
correctly considered when BENDING_TAB_METHOD = M1.

Hull Structural Design:

Incident Issue Description


Number Number
101810 218413 Title: RSO issue for topology points
Symptoms: When using an RSO, defined as Block limit, as one part of a
Topological point defined as Intersection, the system fails with an error.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so also RSO defined as Block Limit will be handled in the
topology point intersection.

Hull Production:

Incident Issue Description


Number Number
94073 200948 Title: Execute bending template run for triangular plate (Bending Template), fatal
error has occure
Symptoms: When run the Bending Template in a triangular plate bending type
(Bending Template), there is a case of fatal error.
Previous/Known workaround: No known workaround exists.
Solution: Correction has been made for the fatail error.
101995 218801 Title: Generate Panel function is not working for nested Framework Panels
Symptoms: Manipulating with an Outfitting Structure object and transfere it to
Manufacturing makes the system to abort.
Previous/Known workaround: No known workaround exists.
Solution: Corrected to the framework (FRMW) will be succefully transfered.
102198 219162 Title: If refer to KN-panel, The angle of autobevel is incorrect.
Symptoms: In some cases where the angle is more acute, the calculation of
bevel against a knuckled panel is not giving the correct result.
Previous/Known workaround: No known workaround exists.
Solution: The angles are now correctly calculated and the expected bevel is
choosen.
102590 220218 Title: Corrug Attribute
Symptoms: Corrug attribute on the MPLATE is always unticked, also when the
plate contains corrugated marking.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so Corrugated will be ticked if the plate contains any
swaging.
The panel must be resplit to get the tickbox updated.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 221 of 517
Product Release Letter
Incident Issue Description
Number Number
103121 221421 Title: Profile Sketch and List - Wrong position of holes and notches
Symptoms: Profile Sketch and List with bending method M1 delivers wrong
positions for holes and notches.
Previous/Known workaround: No known workaround exists.
Solution: Marking distances corrected so that overlength and compensation are
correctly considered when BENDING_TAB_METHOD = M1.
103361 221840 Title: wcog name & type in resulting WCOG.csv file - SP4.36
Symptoms: For collar plates (clips), the resulting wcog list is giving wrote type. It
is in the list, listed as PLANAR PLATE PROFILE.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so COLLAR PLATE will be indicated in the resulting list and
not PLANAR PLATE PROFILE.

Marine Drafting:

Incident Issue Description


Number Number
88452 189340 Title: Request to change confirmation GUI for association between 2D and 3D
View
Symptoms: The confirmation dialog when creating association between a 2D
view and 3D view is confusing for the user.
Previous/Known workaround: No known workaround.
Solution: The confirmation dialog has been improved so it clearly provides the
user with options to update the 2D view from the 3D, update the 3D view from the
2D or cancel the association.
102438 219764 Title: Curve Hull Seams does not appear on marine drafting
Symptoms: No seam symbols are displayed in the surface when making
symbolic views.
Previous/Known workaround: Make the symbolic view in Hull Design and then
use it in Marine Drafting.
Solution: Corrected so the Seam section symbols in the surface will be displayed
also in Marine Drafting.

Outfitting:

Incident Issue Description


Number Number
66722 127110 Title: Piping - In certain configuration, it's not possible to connect branches
Symptoms: NA
Known workaround: NA
Solution: The issue was because the wrong selection of Head and tail
parameters. This has been rectified now in the code.
88179 188784 Title: Piping - PSPOOL Generation: Outfitting claims unexpected Pipe in
Outfitting module.
Symptoms: Pipes not explicitly modified by the user are being clamed
Previous/Known workaround: No known workaround.
Solution: This has now been resolved.
94110 201075 Title: Isodraft - Iso ATTANAME option problem
Symptoms: The ATTA position number for some( not all ) supports are set to S0
in the drawing area, while it has the correct number in the material list.
Previous/Known workaround: None
Solution: When addressing a small 3D skew at a bend, do not introduce a new '-
1' record - it affects the material summary record count. Just zeroize the length.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 222 of 517
Product Release Letter
Incident Issue Description
Number Number
94954 202923 Title: Spooler - Start co-ordinates not shown and End co-ordinates not
transformed by Axes for Spool Drawing starting with an ATTA.
Symptoms: No Start Co-ordinates and End co-ordinates not transformed.
Previous/Known workaround: None.
Solution: Write Base Position (300/301) and Connection (-36) record to Transfer
File.
99503 213338 Title: Create Overlay form doesn't accept reference
Symptoms: 'ref' radio button doesn't enable when OLAY ref entered on form
Previous/Known workaround: Use command line
Solution: Corrected order of operations in form so that the radio buttons enable
appropriately.
99760 213842 Title: Creating Tag Rule set doesn't initially appear in list
Symptoms: On creating a new tag rule set it doesn't get added to the list on the
tag rule library form.
Previous/Known workaround: Navigating to the tag rule library options list and
reselecting the library refreshes the form causing the new rule set to appear.
Solution: The form is now automatically refreshed when a new rule set is created
so it immediately appears in the list.
98525 214316 Title: Piping - Validity of the PTOD attribute
Symptoms: Returned LOD for the branch member
Previous/Known workaround: Get PTOD for the branch itself
Solution: This has now been resolved.
101031 216500 Title: Draft - Configurable dxf export, texts owned by symbol under backing sheet
disappears
Symptoms: Text can't be seen in export because it's obscured by wipeout from
another element.
Previous/Known workaround: Turn off blanking on obscuring element
Solution: Texts now exported last so always effectively on top.
100402 216646 Title: Design - Export RVM files with obstruction and Insulation in TXT format is
not consistent.
Symptoms: OBST primitives marked as insulation.
Previous/Known workaround: Don't use translucent insulation setting.
Solution: This has now been resolved.
102256 219300 Title: Draft - Configurable dxf export uses incorrect width for curved shapes
Symptoms:
Previous/Known workaround: No known workaround.
Solution: Now exported with correct line width.
103162 221603 Title: Design - 'Quick routing', axes are left behind!
Symptoms: QPR axes are left at their old position
Previous/Known workaround:
Solution: Axes now follow the CE.
103406 221947 Title: Isodraft - Pipe piece names in cutting list not the same as in drawing
Symptoms: Pipe piece names in cutting list not the same as in drawing
Previous/Known workaround: None
Solution: Both the missing dimensions and the missing pipe piece numbers were
caused by the existence of zero-length FTUB with SKEYs of ‘TUBE’ at the ends
of branches indicating threaded ends – Isodraw now accommodates these.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 223 of 517
Product Release Letter
12.1.SP4.36

Planar Hull:

Incident Issue Description


Number Number
83731 178218 Title: When you execute to scheme edit, the position of scheme will move from
the pick position.
Symptoms: In a large schema file, when positioning the cursor, the scheme line
will move from the position that is picked.
Previous/Known workaround: Scroll to the right position one more time.
Solution: Automatic scrolling prevented when selecting via mouse in editor
window.
96343 206569 Title: Correction value used along a curve is not correctly translated
when symmetry is modified
Symptoms: For a symmetrical panel, when using right click function Boundary-
>Symmetry->Modify Sym, boundaries using COR for an internal curve will get
wrong sign for the reflected image.
Previous/Known workaround: Manually change the sign in the schema.
Solution: The sign of the boundary limit parallel displacement value (CORR) is
adapted when the limit is defined by an internal curve.
98149 210479 Title: Unwanted reference to RSO
Symptoms: When creating cutouts, the user selects intersecting stiffeners
belonging to an adjacent panel. In the case were the adjacent panel is located by
an RSO, the chosen panel name is ignored in favour of using the RSO reference.
Previous/Known workaround: Manually change to the panel name.
Solution: If the picked stiffener belongs to a panel that is noted as a boundary
limit, the panel name will be used. RSO name will only be used if it is a part of the
boundary.
100075 214635 Title: Wrong flange geometry after panel scheme run
Symptoms: A folded flange gets wrong geometry when run in 12.1.4.34.
Previous/Known workaround: No known workaround exists.
Solution: Flange geometry is correct.
100808 216631 Title: Outfitting structure parts sch files are going to pdmsuser folder not sch
Symptoms: When releasing Outfitting plates to production, the panel schema
files created are saved at the wrong location.
Previous/Known workaround: Manually move the created schema files to the
correct location.
Solution: Corrected so the schemas will be saved in the directory SB_SHIPSCH.
102082 218940 Title: New stiffener issue, endcut angle
Symptoms: The endcut angle for end 2 in the stiffener is wrong.
Previous/Known workaround: This is related to the default keyword
KNUCKLED_STIFFENER and is defined to TWISTED. If set to KNUCKLED or
>NOT SET>, the angles are correct.
Solution: This is now corrected so the endcut angle is as expected also when
TWISTED is defined.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 224 of 517
Product Release Letter
Curved Hull:

Incident Issue Description


Number Number
80264 171004 Title: Curved Panel Symbolis View for reflected shell panel
Symptoms: When attemtping to create a Curved Panel Symbolic View from the
stbd panel of SBP shell, there is no option to create the view specifically for the
stbd panel. Selecting the stbd panel results in a port side Curved Panel view.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that it is possible to make side
specific
Curved Panel View for symmetric panels. The reflection should
be indicated in the selection form.
86073 183547 Title: Shell profiles marking line will not match with Frame ruler.
Symptoms: Adding marking on shell stiffeneres at a frame position, the marking
is not exactly at the frame position.
Previous/Known workaround: No known workaround exists.
Solution: The frame marking is corrected to be exactly at the frame position.

Space Management:

Incident Issue Description


Number Number
100301 214971 Title: Sort the List of RSO's in the "Select and Create" Dialog Box
Symptoms: The list of RSO's presented to the user is not sorted. This makes it
very difficult to find the desired RSO's to use for the Envelope or the Dividing
boundaries.
Previous/Known workaround: No known workaround exists.
Solution: The list is now sorted in alphabetic order.

Hull Production:

Incident Issue Description


Number Number
86705 185003 Title: Outfitting structure parts sch files are going to pdmsuser folder not sch
Symptoms: When releasing Outfitting plates to production, the panel schema
files created are saved at the wrong location.
Previous/Known workaround: Manually move the created schema files to the
correct location.
Solution: Corrected so the schemas will be saved in the directory SB_SHIPSCH.
96758 207752 Title: Nest is not shown in the WCOG for converted flat bar
Symptoms: The name of the nest is not shown in the WCOG for converted flat
bar.
Previous/Known workaround: No known workaround exists.
Solution: Part data (e.g. nest name) for a built profile will now be retrieved also
when the profile is a flatbar.
100235 214797 Title: Through PPM, unknown marking(Type&Name) are output in Gen.file.
Symptoms: In case of marking from an Outfitting plate, the MARKING_TYPE is
undefined.
Previous/Known workaround: No known workaround exists.
Solution: MARKING_TYPE set to OUTFITTING for intersecting outfitting model.
101464, 215745, Title: Error 1002 WCOG
101556 217658, Symptoms: When run WCoG in 12.1.SP4 Fix35, the program will finish with
217794 error 1002 or 1005.
Previous/Known workaround: No known workaround exists.
Solution: Weight and Centre of Gravity List corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 225 of 517
Product Release Letter
Incident Issue Description
Number Number
100791 215958 Title: Bracket marking line will not appear.
Symptoms: Not all brackets are marked on the resulting plate part.
Previous/Known workaround: This can happen when there isa side specific
bracket in a symmetrical defined panel. Place the side specific brackets last in the
panel schema.
Solution: Corrected so all bracket marking will be placed on the parts regardless
of where in the schema they are defined.

Surface Manager:

Incident Issue Description


Number Number
52407, 86584, Title: Surface Manager, Help cannot be opened
46263 104818 Symptoms: By pressing F1 for Help in Surface Manager, nothing happens.
Previous/Known workaround: Open Surface Manager help via AVEVA Marine
Help.
Solution: Help is now available from Surface Manager.

Marine Drafting:

Incident Issue Description


Number Number
101389 217438 Title: WCoG problem of darwing with bracket.
Symptoms: When checking the GWeight of a panel, the weight is too high when
it includs brackets with folded flanges.
Previous/Known workaround: No known workaround exists.
Solution: The excess weight is corrected.

Outfitting:

Incident Issue Description


Number Number
69282 127469, Title: Draft - Export of sheets with heavy use of system glyphs slow and
151585, generated very large .dxf files; Export of system glyphs using characters not
138088 good.
Symptoms: Poor representation of system glyphs.
Known workaround: N/A
Solution: Lines drawn using system glyphs should now correspond to what can
be seen in corresponding plot files.
NB: This fix removes the need for users to have the Quivirs font installed
and accessible to both PDMS & AutoCAD.
72528 148129 Title: Draft - DXF/DWG export incorrect for centreline with flow arrows
Symptoms:
Known workaround: None
Solution: Code now honours the decoration mode and line pattern scaling.
77195, 160873, Title: Line type “ShortDash” become solid line in output DXF drawing
94637 202230 Symptoms: Arcs are drawn solid with too many glyphs
Previous/Known workaround: N/A
Solution: Code now aggregates the spans before placing the glyphs.
The solid line problem is not fixed for arcs that are not circular or elliptical.
98772 212242 Title: Dashed line types become solid
Symptoms: Lines that should be dashed come out as solid
Previous/Known workaround: N/A
Solution: The view scale was being applied incorrectly, resulting in the gaps
being too small for AutoCAD to draw.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 226 of 517
Product Release Letter
Incident Issue Description
Number Number
99971 214341 Title: Aid Text crash fixed
Symptoms: Application would crash when Aid text was zero length
Previous/Known workaround: Don't use zero length Aid text
Solution:Aid text with zero length is now handled correctly in code.
101168 217034 Title: Design - Hole Management: Support for non-linear pipe components with
radius = 0mm
Symptoms: Penetration position incorrect causing validation failure
Previous/Known workaround: Model pipe with components that HM can handle
Solution: Special case for components with radius = 0mm (e.g. Block Angle).

12.1.SP4.35:

Planar Hull:

Incident Issue Description


Number Number
38907 69437 Title: Graphical presentation of twisted stiffeners
Symptoms: The angle looks wrong for twisted stiffeners connected to
intersecting stiffeners.
Previous/Known workaround: No known workaround exists.
Solution: This is a graphical issue in 3D views where the connection angle to an
intersecting stiffener is wrong. This is now corrected so the twisted stiffener is
correctly drawn in 3D views.
59987 105032 Title: Cannot select curved stiffener to end to seam, hole, bracket and panel.
Symptoms: Cannot select curved stiffener, parallel to a limit, to end to seam or
hole.
Previous/Known workaround: End the curved stiffener agains a line definition.
Solution: Corrected so a curved stiffener can end at a seam or hole.
Note that ending at a bracket or a panel are not valid options for curved stiffeners.
77896 162833 Title: Marking "hooks" for abutting panels
Symptoms: There is a possibillity to add end hooks to the markinglines for
stiffeners and brackets when ppanparts is run but there are not any similar
possibillity for abutting planar panels.
Previous/Known workaround: No known workaround exists.
Solution: New default keyword PANMARKHOOK has been added to ppanparts.
The parameters is the same as for STIMARKHOOK.
89008 190601 Title: Cutout/Clip form error
Symptoms: When adding cutouts that have been defined as "Named Cutouts",
the Clip Data tab of the form is not blanked correctly when switching cutout/clip
types.
Previous/Known workaround: No known workaround exists since some fields
may be blocked by the system.
Solution: Corrected so that the form will adapt correctly when cutout type is
changed.
89134, 190840, Title: Flange endcut
91648 196982 Symptoms: For curved flanges, if the endcut angle is more than 90 degrees, it is
not presented in any views.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved for endcuts in curved flanges with angle
bigger than 90 degrees.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 227 of 517
Product Release Letter
Incident Issue Description
Number Number
93554 200064 Title: Graphical presentation of twisted stiffeners
Symptoms: The angle looks wrong for twisted stiffeners connected to
intersecting stiffeners.
Previous/Known workaround: No known workaround exists.
Solution: This is a graphical issue in 3D views where the connection angle to an
intersecting stiffener is wrong.
This is now corrected so the twisted stiffener is correctly drawn in 3D views.
95390 203858 Title: RSO use in Boundary Wizard
Symptoms: In boundary wizard when using intersecting panel, the ROS tickbos
is always checked.
Previous/Known workaround: Manually uncheck the tickbox.
Solution: A new variable has been added to the default handling to let the
system have a default state of which tickboxes that should be set.

BOU_INT_PANRSO <value>
where <value> can be either RSO or PANEL.
If set to RSO, the RSO tickbox will be checked and the Panel tickbox unchecked.
If set to PANEL, it will be the reversed.
If not defined, both tickboxes will be checked.
95734 204849 Title: Issues with 3D View
Symptoms: The presentation of curved plates is corrupted. but the parts are ok.
Previous/Known workaround: No known workaround exists.
Solution: The presentation of curved plates has been improved.
96763 207263 Title: When panel store Pre trigger is aborted, panel is skipped
Symptoms: When the Pre trigger is aborted, he panel is not stored but it is
skipped so all changed information is lost.
Previous/Known workaround: No known workaround exists.
Solution: Panels that are not stored are now not deactivated. This is valid both
for panels where the pre trigger result is other than OK and for panels where the
user doesn't confirm storing.
96901 207554 Title: Auto PosNO application: Comparison statement '/COMP PANEL' doesn't
work.
Symptoms: Comparison statement '/COMP PANEL' acts in same way as
'/COMP_SCOPE'(application default comparison statement)
Previous/Known workaround: No known workaround exists.
Solution: The position number start from beginning again if comparison is panel.
97284 208733 Title: Bracket instance quality issue
Symptoms: System accepts any other quality, but not the one stated in
bracket_instance file.
Previous/Known workaround: Manually change quality in the schema
Solution: This problem occured when DEF_QUAL_OUT is set in the default file.
It is now fixed so that default quality will no longer appear in the statement if the
bracket has an instance that givs qualtity.
98230 210579 Title: NUM statement only works for horizontal panels
Symptoms: NUM statement for material in PLA is not working correctly
Previous/Known workaround: Do not use NUM for material assignment.
Solution: The material for plates can now handle NUM values.
98244, 210608, Title: Bracket instance quality issue
80203 170615 Symptoms: System accepts any other quality, but not the one stated in
bracket_instance file.
Previous/Known workaround: Manually change quality in the schema
Solution: This problem occured when DEF_QUAL_OUT is set in the default file.
It is now fixed so that default quality will no longer appear in the statement if the
bracket has an instance that givs qualtity.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 228 of 517
Product Release Letter
Incident Issue Description
Number Number
98243 210611 Title: Numerical variables not usable in a boundary's free side
Symptoms: In a boundary statement with a definition of a free side NUM
replacement is not accepted for the keyword “LEN(gth)”.
Previous/Known workaround: Do not use NUM value in LEN keyword when
defining Free Side.
Solution: It is now possible to define NUM values for all FREE side parameters.
98583 211572 Title: Multiple (de)selection of views impossible if not switched to PHM before
Symptoms: Active symbolic and model views can be selected and deselected
using function Symbolic View -> Planar Hull View/ Curved Hull View -> Select.
When AM is initially started with Curved Hull Modelling selected, the “Options” –
button to enable multiple view (de)selection is not available if GEN_VIEW =
SINGLE is set in sj700.sbd. User needs to switch once to Planar Hull Modelling
and back to Curved Hull Modelling to make the “Option” button and multiple
(de)selection available.
Previous/Known workaround: See Symptons.
Solution: The default handling has been changed to allow GEN_VIEW to be
altered/defined also in curved hull.
99021 212218 Title: WCOG of SBP panel incorrect
Symptoms: Weight on relfected plate on a symmetrical panel is not correct when
holes are side specific.
Previous/Known workaround: Make the panels side specific instead of SBP.
Solution: Corrected so the weight for the reflected panel is showing the correct
weight.

Curved Hull:

Incident Issue Description


Number Number
92426 198276 Title: Shell Expansion - Longitudinal numbers PS&SBappear on top of each
other
Symptoms: Create a shell expansion view over CL. The shell expansion shows
the longitudinal numbers on PS & SB. Then - when using function Tools -> Model
View -> Exchange and “All” -> From Model - then the longitudinal numbers on SB
disappear and on PS - there are double numbers on top of each other.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the long numbers gets correct.
92608 198564 Title: ShellX over CL, Endcut symbols of Cstiffs point to the wrong direction
Symptoms: ShellX over CL, Endcut symbols of Cstiffs point to the wrong
direction after Model View Exchange or Model Modify
Previous/Known workaround: No known workaround exists
Solution: The problem has been solved so that the endcut symbols points in the
right direction.
97005 208533 Title: Modify cstiff group- modification of conn angle to "from parameters"
properly only with other change
Symptoms: When modifying a group of cstiffs and changing connection angle to
"From parameters" without other modifications (like endcut type) this is done
properly for the first cstiff in selection only. For all other cstiffs in group
parameters fitting to old endcut geometry are calculated automatically.
Previous/Known workaround: Modify stiffeners one by one.
Solution: This has been solved so that all selected stiffeners are modified when
oly connection angle is changed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 229 of 517
Product Release Letter
Incident Issue Description
Number Number
97214 208579 Title: Modifying Shell Profile features cause fatal error with
SBH_FREE_SEAMPROF_NAMES
Symptoms: System aborts when trying to modify a feature (hole/notch/cutout) of
a Shell Profile
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that it is possible to modify features of
free naming profiles.
96704 210590, Title: New P-points for a CSTIFF element
207155 Symptoms:
There is a need for p-points at the start and endpoints of the shell stiffener trace
as well as at the points adjusted for any clearance etc.
Previous/Known workaround:
None
Solution:
There are 5 new p-points added to the CSTIFF element:
0: Midpoint of trace, same as for the POS attribute.
1: Starting point of the trace curve
2: Point at physical start of stiffener
11: End point of the trace curve
12: Point at physical end of stiffener
Point 2 and 12 do not take the endcut geometry into account.
99067 212462 Title: Profile Cutting Inteface - wrong description of bending line contour
Symptoms: When creating a generic file for a nested curved profile the
description of the contour of the first inverse bending line from left end misses
several points at its beginning.
Previous/Known workaround: No known workaround exists.
Solution: Visualisation of inverse bending contours corrected in generic file for
BENDING_TAB_METHOD=M2.
99187 212780 Title: not possible to set text and symbol heigth in Shellx views
Symptoms: The text size in ShellX view is fixed and not possible to define.
Previous/Known workaround: Manually change the text height of resulting test
in the view.
Solution: Two new default keywords has been added to be able to control the
text and symbol size in the ShellX view.

SHX_TEXT_HEIGHT=<height> (default value = 2.5)


SHX_ENDCUT_SYMB_HEIGHT=<height> (default value = 1.5)

Please note that this will also affect the Curved Panel view and Body Plan view.

Hull Structural Design:

Incident Issue Description


Number Number
58956 102129 Title: Graphical presentation of twisted stiffeners
Symptoms: The angle looks wrong for twisted stiffeners connected to
intersecting stiffeners.
Previous/Known workaround: No known workaround exists.
Solution: This is a graphical issue in 3D views where the connection angle to an
intersecting stiffener is wrong.
This is now corrected so the twisted stiffener is correctly drawn in 3D views.
76858 160271 Title: FR/LP Table - Interactive function unstable
Symptoms: The interactive function of FR/LP coordinates is only handling one
decimal.
Previous/Known workaround: No known workaround exists.
Solution: Support for two decimals has been added.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 230 of 517
Product Release Letter
Incident Issue Description
Number Number
91418 196593 Title: Flange endcut
Symptoms: For curved flanges, if the endcut angle is more than 90 degrees, it is
not presented in any views.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved for endcuts in curved flanges with angle
bigger than 90 degrees.
92841 198894 Title: Dimmed Indicate Icon for RSO > EDIT
Symptoms: In RSO->Edit, the Indicate icon is dimmed. this makes it hard to
change related conditions.
Previous/Known workaround: No known workaround exists.
Solution: Functions now available when re-entering the edit function.
100115 214534 Title: Hull Init Registration more than 100 surface
Symptoms: When adding additional surfaces in Inithull, there is a limit of 100
surfaces.
Previous/Known workaround: Add the surfaces in Hull Structural Design
function "Project->Surfaces...>
Solution: The limit of 100 surfaced in Inithull is changed to 1000.

Space Management:

Incident Issue Description


Number Number
97306 208795 Title: Space Management Issue " Module Not Defined in File "
Symptoms: After Generating Space World SPMSW by a command , if user set
space arragement type by SPMTYP from attribute dialog , then if the user try to
create Space Arrangement , ssytem gives error message " Module Not Defined in
File ".
Previous/Known workaround: No known workaround exists.
Solution: When the space world was created from the command line and the
space world type was changed prior to creating the space arrangement the
initialisation routine creating all necessary database elements was not called.
This has been fixed.

Hull Production:

Incident Issue Description


Number Number
97282 208728 Title: "+ gap" is twice added to deployed bracket.
Symptoms: when running ppanparts on brackets where bevel, with gap, is
assigned, the gap is applide twice to thee limit of teh bracket.
Previous/Known workaround: No known workaround exists.
Solution: The gaps have been adjusted.
98688 211677 Title: Custom Notch error in profile
Symptoms: Customised notches not possible to use in profiles. Error in
ppanparts.
Previous/Known workaround: No known workaround exists.
Solution: The user defined customised notches for stiffeners are handled in
ppanparts.
98655 211678 Title: Missed value for pillar in MANU
Symptoms: Parameter 2 for pillar type Tube (70,71 and 72) is missing in the
MANU part attribute.
Previous/Known workaround: No known workaround exists.
Solution: The thickness of the tube is now presented in the attributes.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 231 of 517
Product Release Letter
Hull Nesting:

Incident Issue Description


Number Number
93670 200233 Title: Plate nesting crashes after opening nestedplate
Symptoms: When opening an old nest and confirming that there are some parts
that has changed, the system aborts.
Previous/Known workaround: No known workaround exists.
Solution: The error has been corrected. The nesting may have a mismatch
between the starts and the actual number of contours on the parts. Please also
re-define the starts.
94577 202099 Title: Error 2500 when trying to open existing nest.
Symptoms: When opening an old nest, the system responds with the error code
2500.
Previous/Known workaround: No known workaround exists.
Solution: The error 2500 is a general error. It has been split up in more precise
error codes incidating for the user what is tha actual issue.
95127 203344 Title: Nesting form Issue
Symptoms: When part table in the Nesting Sketch is created on the following
sheets, not used colums is still filled in with the last part.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so not used field are empty.
98385 211046 Title: System Error 2532!
Symptoms: When creating a nest with cutline and then reopens it the message
"System Error 2532!" with an explanation "fatal error retrieving the contour
number from the attribute number" occures.
Previous/Known workaround: An appearance of this error is depend on the
parameter MAX_CONTOUR. If MAX_CONTOUR = -1 (not limited parts) the
System Error 2532 will be set. If other value is assigned, the error doesn't appear.
Solution: The error has been corrected so the value -1 can be used for
MAX_CONTOUR when using cutline.

Marine Drafting:

Incident Issue Description


Number Number
12367, 51484, Title: Tools > Inquiry > model
84261, 180445, Symptoms: Model Info does not work for Outfitting models.
42994, 67230, Previous/Known workaround: No known workaround exists.
48965 77393 Solution: It is now possible to use "Model Info" for outfitting models through the
PML Trigger "trigdraftmodelinfopre.pmlfnc". For more information refer to section
Enhancements above.
84188 186642 Title: Flange endcut
Symptoms: For curved flanges, if the endcut angle is more than 90 degrees, it is
not presented in any views.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved for endcuts in curved flanges with angle
larger than 90 degrees.
88012 189022 Title: AUTOTAGG_Not tagged all models
Symptoms: When removing the 2D restriction of a model view, not all items are
tagged.
Previous/Known workaround: No known workaround exists.
Solution: The issue regarding autotagging not tagging all models when a 2D
restriction is removed has been fixed. The new window size is set to sheet size or
bigger when the 2D restriction is removed, in order to include all models in the
view, resulting in all models being tagged when updated.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 232 of 517
Product Release Letter
Incident Issue Description
Number Number
88464 189371 Title: Picking behavior in Marine Drafting is different from Outfitting.
For information about this enhancement refer to section Enhancements above.

Schematic 3D Integrator:

Inciden Issue Description


t Number
Number
90358 194989 Title: Stop flange comparison in Schematic 3D Integrator
Symptoms: Integrator will compare flanges if these are defined on the P&ID.
The category for other components does not work to exclude their errors from the
report.
Previous/Known workaround: N/A
Solution: Flanges are now included under the Other Components category to
exclude their errors from the report.
90624 196130 Title: Sequence error in comparison still showing in Schematic 3D Integrator
Symptoms: If sequence errors are switched off in the configuration category,
they are still appearing with red icons in the report
Previous/Known workaround: N/A
Solution: Sequence errors are properly suppressed in the report if switched off
in the configuration category.
97921 209932 Title: Issues about argument of findOnDrawing method
Symptoms: When given an array of schematic objects, not all drawings were
opened and zoomed to the selected objects
Previous/Known workaround: Run objects one at a time
Solution: Given an array of schematic objects, the findOnDrawing method opens
all the appropriate diagrams, highlights and zooms to the object.

Mechanical Equipment Interface (MEI):

Incident Issue Description


Number Number
93337 200059 Title: MEI - Failed to export HIBLO
Symptoms: Error message when trying to export idealised shell plates.
Previous/Known workaround: No known workaround exists.
Solution: The handling of idealised shell plates has been fixed, they were not
exported at all. Another bug that prevented the export of a number of flanges in
idealised shell stiffeners is also fixed.

Pipe Fabrication:

Incident Issue Description


Number Number
71091 143292 Title: Socket Weld Handling
Symptoms: Welds on spec cannot be used for socket welds.
Known workaround: None
Solution: The problem modifed to append the new option "Create Socket Welds
from Spec" for Socket weld and "From Spec" for Welds for Slip-on Flanges.
Please note that "Create Socket Welds from Spec" and "From Spec" on the
"Welds for Slip-On Flanges" will works only "SPEC" on the "Weld Handling" form
is selected. And, the weld spec for socket weld from current pipe spec. That is, it
is not allows that we cannot use alternative spec for weld. This is limitation.
Because, "Choose All" command is used for creating weld at the moment.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 233 of 517
Product Release Letter
Incident Issue Description
Number Number
93751 200324 Title: Pipe Fabrication, Mutiple Spools - wrong feedback to user when "Create..."
Symptoms: The highlight os the spool limits is incorrect, spool limits are not
considered
Previous/Known workaround: No known workaround.
Solution: The highlighting of the spool limits selected while adding to the spool
drawing needs to be fixed by considering the attributes say AsfBreak, LsfBreak
along with CsfBreak.
Code change has been made to the pfevaluatespoolmember.pmlobj in
highlighting the selected spool limits.
94120 201065 Title: Excess were not correct if the flange was loose and has welds
Symptoms: If a pipe has loose flanges and welds then excess were not correct
Previous/Known workaround: None
Solution: We have updated the functionality when setting end excess also so
that if you set the end excess on some tube that has welds either side that the
component the weld is for is checked to see if it is loose. If so the excess will be
applied to the component rather than the weld. If the component is not loose then
the excess is applied to the weld.
94698 202383 Title: Fabrication Check - Incorrect Bend Program with Loose Excess
Symptoms: A problem occurs with the Length Inside/Length Outside/Bending
Act values when the spool has a Loose component and requires a 50mm excess.
Previous/Known workaround:
Solution: ArriveExcess is already added to the ArriveTubeLength in
InitializeCheckResult of PFFabricationMachineManager
LeaveExcess is already added to the LeaveTubeLength in InitializeCheckResult
of PFFabricationMachineManager. Hence while calculating the Machine Outside
Length in the CheckInsertionLength in PFFabricationMachineManager, the
ArriveExcess/LeaveExcess are excluded. Also while calculating the
bendingActivities, the feed is calculated by excluding ArriveExcess/LeaveExcess.
Bending Arrive Excess and Bending Leave Excess are considered when
calculating the Machine Outside Length in the CheckInsertionLength in
PFFabricationMachineManager. Bending Arrive Excess and Bending Leave
Excess are also considered when lculating BendingActivities in
GetBendingActivities of PFBendingMachine.
95174 203333 Title: We don't handle expressions being used for the UWEI attribute when
calculating the FTUB weight of a pipe end
Symptoms: Some customers use expressions to calculate the UWEI attribute
when calculating the FTUB weight for a pipe end. As a result this would fail and
the incorrect weight would be supplied.
Previous/Known workaround: Use actual values rather than expressions
Solution: We now parse the expressions correctly and they can now be used in
the calculation process. Additionally, other changes are required to update the
piping specs, property database and the FTUB dataset in order for these weights
of a pipe end to be calculated correctly. These macros should have been
released along with the fix and instructions for running them should have been
included.
97297 208772 Title: Modifying welds does not report incorrect stype
Symptoms: Users are not warned if the incorrect stype is used
when modifying the weld
Previous/Known workaround: None
Solution: We now inform the user during weld modificaiton if we are unable to
update the spec, as the STYP being used is not defined in the spec.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 234 of 517
Product Release Letter
Incident Issue Description
Number Number
97300 208786 Title: 12.1.SP4.34 - PF - Setting Spool Limits Fails on Unconnected Tee
Symptoms: It is not possible to set the Spool Limits on a Tee if the p3 of the Tee
is not connected.
Previous/Known workaround:
Solution: The cref of TEE is being considered for allowing the spool limits on
TEE.
97798 209663 Title: Isodraft - once FAIL DOUBLE BACK PIPE, all subsequent PIPEs in Detail
List show same error
Symptoms: Isodraft - once FAIL DOUBLE BACK PIPE, all subsequent PIPEs in
Detail List show same error
Previous/Known workaround: None
Solution: Zeroize &INOSFT for possible further pipes.
210582 Title: We don't handle expressions being used for the UWEI attribute when
calculating the FTUB weight of a pipe end
Symptoms: Some customers use expressions to calculate the UWEI attribute
when calculating the FTUB weight for a pipe end. As a result this would fail and
the incorrect weight would be supplied.
Previous/Known workaround: Use actual values rather than expressions
Solution: We now parse the expressions correctly and they can now be used in
the calculation process. Additionally, other changes are required to update the
piping specs, property database and the FTUB dataset in order for these weights
of a pipe end to be calculated correctly. These macros should have been
released along with the fix and instructions for running them should have been
included.

Outfitting:

Incident Issue Description


Number Number
24857 58194 Title: Isodraft - Incorrect Piece No with Branch's MTOH off (Set-on TEE
Connection)
Symptoms: Incorrect Piece No with Branch's MTOH off (Set-on TEE
Connection)
Known workaround: None
Solution: Do not check for end flange if dotted and no dimension.
41230 66937 Title: Piping - Components positioned on a Branch in an order inconsistent with
their model positions when ATTAs with SPKBRK false are involved.
Symptoms: Isometric dimension problems.
Known workaround: Reorder manually.
Solution: Use new ATTABREAK command to temporarily assume all ATTAs are
SPKBRK true.
38883 69434 Title: Spooler - Components positioned on a Branch in an order inconsistent with
their model positions when ATTAs with SPKBRK false are involved.
Symptoms: Isometric dimension problems.
Known workaround: Reorder manually.
Solution: Use new ATTABREAK command to temporarily assume all ATTAs are
SPKBRK true.
53825 89667 Title: Design - Model Editor selection highlight lost
Symptoms: Selection highlight lost when the selection is moved or rotated by the
Model Editor
Known workaround: Unknown
Solution: Selection highlight is now preserved when the selection is moved or
rotated by the Model Editor.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 235 of 517
Product Release Letter
Incident Issue Description
Number Number
74720 153097 Title: Isodraft - Fonts incorrectly exported to dxf from IsoDraft
Symptoms: Text using (eg) Cyrillic characters exported incorrectly
Known workaround: None
Solution: Code modified to export data as escaped Unicode and specify
appropriate font in exported dxf.
85483 182387 Title: Welds positioned on a Branch in an order inconsistent with their model
positions when ATTAs with SPKBRK false are involved.
Symptoms: Isometric dimension problems.
Previous/Known workaround: Reorder manually.
Solution: Use new ATTABREAK command to temporarily assume all ATTAs are
SPKBRK true.
85804 183124 Title: Design - Pipe Editor Error fixed
Symptoms: In certain contexts the Model Editor was showing the Pipe Editor
handles
Previous/Known workaround: None
Solution: The correct handles (the generic Model Editor handles) are shown at
the first/last component where a branch breaks.
85806 183209 Title: Design - When the pipe model that included ATTA and ended TUBE is
modified, TAIL remains origin location.
Symptoms: When the pipe model that included ATTA and ended TUBE is
modified, TAIL remains origin location.
Previous/Known workaround: Unknown
Solution: When the pipe model that included ATTA and ended TUBE is modified,
the branch TAIL is modified accordingly.
88433 189308 Title: ADP - HVAC Isometric Extraction problem
Symptoms: Unable to extract HVAC Isometric Drawings from PDMS using
Isometric ADP.
Previous/Known workaround:
Solution: Checks have been put in place to determine whether
AVEVAHVACMTO or CADCHVACMTO should be used in
mtohvacparameters.pmlfnc, this prevents the error and drawings are extracted
successfully.
88783 189948 Title: Design - PVIF attribute mismatch (Paragon)
Symptoms: Invisible ppoints displayed in Design
Previous/Known workaround: None
Solution: Now fixed.
89011 190490 Title: Design - Can now pick ppoints for translucent insulated piping
Symptoms: Ppoints can't be picked
Previous/Known workaround: Turn insulation off.
Solution: Now fixed.
89963 192702 Title: Design - Problem with collect exactly and gtroom with stwall elements
Symptoms: Failed to allow for JUSL setting
Previous/Known workaround: set JUSL to NA & move SCTN
Solution: Now fixed.
91063 195347 "Utilities>Import" doesn't accept over 6 characters Password.
75834 196238 Title: Isodraft - Flangolet problem in isometric
Symptoms: When the Skey is set to WNFL (which is required), the symbol
doesn't appear as dotted and appears in the material list in the flanges section
with wrong descriptions some times gasket and other times elbow!!.
Previous/Known workaround: None
Solution: A Flange is added to the top of the Flangolet because of the end
condition of ‘FL’ – rightly so. However this Flange is not inheriting the dotted and
suppressed MTO attributes from the Flangolet and was attempting to be placed in
the MTO. Solution: Save the details from the Olet for use later.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 236 of 517
Product Release Letter
Incident Issue Description
Number Number
91361 196517 Title: Design - PEROP error messages ignored by the Model Editor
Symptoms: PEROP error messages not displayed by the Model Editor; a
generic message is displayed instead.
Previous/Known workaround: Unknown
Solution: PEROP error messages are now displayed by the Model Editor.
92857 199258 Title: Design - Problem with spec bore change on a single branch
Symptoms: After re selecting the components of a branch the head is re-
connected to the wrong end of the previous branch
Previous/Known workaround: Reconnect using the modify pipe form
Solution: The application now works out which end to connect.
93372 199723 Title: Users are informed there are errors with their current pick when it was for
their previous pick.
Symptoms: If a user chooses to create some welds via pick and it errors, they
will be constantly reminded in subsequent picks even if there are no errors with
the new picks.
Previous/Known workaround: None
Solution: We now reset the error list in between each of the picks.
93904 200654 Title: Reordering elements by name put wrong weight against that name
Symptoms: Misaligned name / weight in list
Previous/Known workaround: Do not reorder columns prior to calculating
weights, do it after.
Solution: Issue resolved.
93405, 200991, Title: Reporting: The sum functionality inside the reporting functionality is not
93982 201052 working as supposed.
Symptoms: Sum functionality not working correctly
Previous/Known workaround: N/A
Solution: The sum will now work fine.
93982 201052 Title: Isodraft - Component showing the wrong symbol
Symptoms: Component showing the wrong symbol
Previous/Known workaround: None
Solution: Check if a flange has been supplied already.
94654 202293 Title: Visualisation - PPOINTs not shown on pipe fittings
Symptoms: If obstruction translucency is on, PPOINTs were not being shown
when using the measure tool to select a pipe in the view
Previous/Known workaround: Set the pick filter to Ppoint
Solution: Change the sorting order of potential pick hits, so that the first one
encountered is returned with higher priority.
92483 203130 Title: Isodraft - Additional Cutlength Reported in Isometric Cutlength Table
Symptoms: Additional Cutlength Reported in Isometric Cutlength Table
Previous/Known workaround: None
Solution: Take account of Connection Comments when calculating cut lengths.
95164 203304 Title: Structures - The position of Ladder does not exported(RVM) correctly.
Symptoms: Ladder in wrong position
Previous/Known workaround: None
Solution: Now fixed.
95450 203931 Title: Design - Aborted NSBC due parallel Points/Vectors
Symptoms: The NSBC application fails to connect branches with a vector
problem
Previous/Known workaround: None
Solution: The parallel vector error is now handled as it should be and the
application works correctly.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 237 of 517
Product Release Letter
Incident Issue Description
Number Number
95910 205206 Title: Admin - PDMS Entry error - Arc tolerance less than minimum
Symptoms: Could not enter PDMS
Previous/Known workaround: Delete des-rep.pmldat from %PDMSUSER%
Solution: Firstly... handle any error on entry so even if the serialisation file has
0mm in then it is corrected to a valid value.
Secondly... prevent the user from getting a 0mm in the serialisation file by putting
validation call on the Graphical Representation Settings form.
95703 205486 Title: Elbow specs(spref) are being initialized illegally
Symptoms: When using quick routing, if the last elbow's SPREF is changed and
quick routing is used again, the previous elbow's SPREF is restored.
Previous/Known workaround: None
Solution: When using quick routing, if the last elbow's SPREF is changed and
quick routing is used again, the elbow's new SPREF is preserved.
72589 205907 Title: Draft DFLTS files - Invalid Syntax
Symptoms: Layer defaults not set correctly
Previous/Known workaround: Set values manually after creating the layer
Solution: Syntax corrected.
Note that in most cases, the errors did not matter as the correct defaults were
used anyway.
96170 206083 Title: Piping - Unable to add Quick Pipe Router Bends to an empty BRANCH
Symptoms: Blobs disappear on an empty branch with HDIR and TDIR are anti-
parallel and amost on the same line, and the user double-clicks on the dotted
line.
Previous/Known workaround: No known workaround.
Solution: Blobs no longer disappear.
96965 207927 Title: Copy function error
Symptoms: Element names containing single quotes are not handled correctly
in the Explorer.
Previous/Known workaround: Do not use quotes in element names
Solution: Single quotes in element names can now be handled correctly by the
Explorer.
97072 208496 Title: Piping - Unable to determine the bending radius for a BEND being added
after a PTAP
Symptoms: The component creation form could not find the correct radius if a
user was currently at a pipe tapping.
Previous/Known workaround: Set the radius manually
Solution: This was due to a problem with the wall thickness query in the client
project. Wall thickness at a PTAP is a problem because it comes fro a different
spec so the solution is to use the tube wall thickness instead as this is likely what
the PTAP is inserted into.
97177 208558 Title: Draft - Text in a SYMB on a BACKing sheet is not exported
Symptoms: No text appears
Previous/Known workaround: N/A
Solution: The export now works if the SYMB is on a BACKING sheet.
97334 208855 Title: Piping - Error when creating a new RETURN ELBOW
Symptoms: An error (2,785) Unset/Invalid object passed to method is shown
when creating a return bend.
Previous/Known workaround: This causes no loss of functionality its just
annoying.
Solution:The component creation form now intercepts the error.
97593 209368 Title: Isodraft - once FAIL DOUBLE BACK PIPE, all subsequent PIPEs in Detail
List show same error
Symptoms: Isodraft - once FAIL DOUBLE BACK PIPE, all subsequent PIPEs in
Detail List show same error
Previous/Known workaround: None
Solution: Zeroize &INOSFT for possible further pipes.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 238 of 517
Product Release Letter
Incident Issue Description
Number Number
99226 212854 Title: Piping - TUBI now exported if in a GPSET
Symptoms: TUBI missing
Previous/Known workaround: Export the pipes or branches.
Solution: Now fixed.
99231 212861 Title: Draft - Selecting Truetype Backing Sheet on dept & regi creation causes
Warning message
Symptoms: An inappropriate warning appears
Previous/Known workaround: Press APPLY before changing tabs
Solution: Does additional check if data on form has been changed but not
applied yet.

12.1.SP4.34

Initial Design:

Incident Issue Description


Number Number
93067 199285 Title: Internal Surface and compartment dialogs allow user to give id with spaces
Symptoms: If user name internal surfaces and compartment with spaces in
names they will not be released to dabacon properly and will not show up in
design applications.
Previous/Known workaround: Don't enter name with spaces in Surface &
Compartment if object are to be released to dabacon, that even if Surface &
Compartment application allows it.
Solution: Code change applied that prevents user from creating internal surfaces
and comaprtnments with spaces in id.

Planar Hull:

Incident Issue Description


Number Number
39305, 67620, Title: Curve hull seams shows inside of hull in section view
25686, 75622, Symptoms: In certain cases, the Hull Seam symbol is on the wrong side of the
55825, 93644, Hull Section Curve in Hull Symbolic Views.
56078 96282 Previous/Known workaround: No known workaround exists.
Solution: The issue with seam symbols in Hull Symbolic Views (HSV) has been
corrected. The symbols are placed with respect to the surface normal that is
defined to the surface patch. The normal for the patches can be checked with
help of the Surface Manager.
67284 134921 Title: Enhancement for Marking name
Symptoms: In Statement Wizard, it is only possible to set name for marking
defined by two positions.
Previous/Known workaround: No known workaround exists.
Solution: Name field for Marikings in Planar Panel Statement Wizard has been
opened up for all types of marking.
Special case for Marking for Curve. If wekd information is given, the marking
name will not be included in the resulting generic file. it is then the weld
information that is presented and not the name.
75801 157041 Title: Improvement to open hole via Equipment in a flat area in Knuckled Panel.
Symptoms: Equipments could not use to open hole to knuckled panel in Hole
Management.
Previous/Known workaround: No known workaround exists.
Solution: Holes can now be created by Equipment in flat areas of the Knuckled
Panel.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 239 of 517
Product Release Letter
Incident Issue Description
Number Number
95025 203052 Title: Bracket Excess does not accept to define negative number
Symptoms: Bracket Excess has been enhanced since AM12.1 SP4.28Fix,
when defining a negative number for Bracket Excess, it is gone from the scheme.
Previous/Known workaround: No known workaround exists.
Solution: Negative excess is now handled both in panel generation and
PPanParts.
94563 203346 Title: Part size is strange using Bevel Basic Type 39
Symptoms: The size of resulting plate part is not correct when bevel type 39 is
used.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so plate part using bevel type 39 has correct size.

Curved Hull:

Incident Issue Description


Number Number
83946 178626 Title: Shell profile is on wrong side
Symptoms: Shell profiles is sometimes drawn on the wrong side of the surface.
Previous/Known workaround: No known workaround exists.
Solution: A major correction is done for this problem. Shell profiles are now
depended on the surface normal (can be viewed in Surface Manager). Outside is
defined as the same direction as the normal of the surface.
88938 190308 Title: Shell profile is on wrong side
Symptoms: Shell profiles is sometimes drawn on the wrong side of the surface.
Previous/Known workaround: No known workaround exists.
Solution: A major correction is done for this problem. Shell profiles are now
depending on the surface normal (can be viewed in Surface Manager). Outside is
defined as the same direction as the normal of the surface.
89297 191284 Title: Curve hull seams shows inside of hull in section view
Symptoms: In certain cases, the Hull Seam symbol is on the wrong side of the
Hull Section Curve in Hull Symbolic Views.
Known workaround: No known workaround exists.
Solution: The issue with seam symbols in Hull Symbolic Views (HSV) has been
corrected. The symbols are placed with respect to the surface normal that is
defined to the surface patch. The normal for the patches can be checked with
help of the Surface Manager.

Hull Structural Design:

Incident Issue Description


Number Number
75537 156241 Title: NOENDCUTSYMB parameter
Symptoms: The NOENDCUTSYMB parameter do not work if STRUCTURAL
DESIGN or CURVED HULL is used.
Previous/Known workaround: Manually change teh variable after system
startup.
Solution: Default for Hull Structural Design for the parameter NOENDCUTSYMB
will be that no endcut symbols are shown in symbolic views. For Detail Design,
the default is that endcut symbols are shown.
94579 202103 Title: The path length of SBH_CONCODES
Symptoms: THe pathlength for the file assosiated with SBH_CONCODES can
only be 80 characters long.
Previous/Known workaround: Make sure the definition of SBH_CONCODES
are less than 80 character long.
Solution: Total filename is changed to acceppt up to 512 characters.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 240 of 517
Product Release Letter
Incident Issue Description
Number Number
95029 203063 Title: When divided panel, Detault"SCH_CREATE" is changed to <NOT SET>.
Symptoms: See Title.
Previous/Known workaround: No known workaround exists.
Solution: The value of SCH_CREATE is now preserved even when using Block
Division.
95101 203216 Title: When divided panel, Additional endcut types is changed on the type of
cutters.
Symptoms: When divided panel, Additional endcut types is changed on the type
of cutters.
-Principal plane has endcut type(xx00)
-RSO has endcut type(xx20)
Previous/Known workaround: Manually change endcut after the panel is
divided.
Solution: Cutters by principal plane and and by RSO are now treated the same
with respect to connection and endcut codes.
95563 204147 Title: AM 12.1.SP4.32 - Frame Grid limited to 500 frames only.
Symptoms: For some projects, 500 frame limit is not enough.
Previous/Known workaround: No known workaround exists.
Solution: Limit of frames has been extended to -99:800.
Once frame numbers has been added above 500, previous versions of the
system should not be used since those versions do not recognize higher
numbers.
Also rules for SB specific profiles are changed.
SB specific transversals get an additional number of 10 000 (previous 5 000).
SB specifi longitudinals in main surface gets additional 12 000 (previous 2 000).
SB specifi longitudinals in deck surface gets additional 13 000 (previous 3 000).
Note that the rules only affects Split Profile and numbering in symbolic views.
Free named profiles are not affected by the rules.

Surface Manager:

Incident Issue Description


Number Number
95255 203556 Title: Surface Manager splits curves
Symptoms: Import IGES Curve from File into Surface Manager divides the
Curve into several Contours.
The curves are usually Chained in the Source Application Rhino.
Previous/Known workaround: No known workaround.
Solution: The import option "Split curves into continuous segments" is true by
default. Set it to false in the iges import then one logical curve in the file will be
returned as one complete curve.

Hull Production:

Incident Issue Description


Number Number
63104 115460 Title: Useless excess for an expanded bendpanel
Symptoms: Bent plate (outfitting plate) is too big when produced.
Previous/Known workaround: No known workaround exists.
Solution: The resulting plate part from an OSP bent plate is too big. This is
corrected so the result plate part will have correct size.
97282 208728 Title: "+ gap" is twice added to deployed bracket.
Symptoms: See title
Previous/Known workaround: No known workaround.
Solution: The gaps have been adjust.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 241 of 517
Product Release Letter
Hull Nesting:

Incident Issue Description


Number Number
95260 203685 Title: Function "Keep parts already in menu"
Symptoms: When ticking the "Keep parts already in menu" in the Parts Menu
selection menu, no parts are added to the Parts Menu.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so additional parts will be added to the Parts Menu also if
parts are to be kept in the menu.

Marine Drafting:

Incident Issue Description


Number Number
80358 171212 Title: Underline is applied to all of the text in the View Replace.
Symptoms: When you run the View replace with Underline with Text placed in a
View, Underline is being applied to all text in the view.
Previous/Known workaround: Manually change fault text.
Solution: A new value to the default keyword VEW_TEXT_PROPERTY has
been added. If set to VIEW, the text properties used when the view was first
created, will be kept in the view when it is re-created.

Please note: The keyword VIEW for default VIEW_TEXT_PROPERTIES behaves


the same as the keyword FULL on views created before this release.
88214 188780 Title: 'GLAB' 'SLAB' go back to original location.
Symptoms: After scale modified, the text of 'GLAB' 'SLAB' go back to original
location in the 12.1 Marine Drafting.
Previous/Known workaround: No known workaround exists.
Solution: The issue regarding SLAB not being scaled properly when modifying
the drawing scale has been fixed.
91030 195267 Title: Bad Line Types in ShellX over CL when using SHELLX_LT_COL
Symptoms: Line types are reversed in over CL ShellX views. Outside becomes
insiade and vice verca.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the line types get correct in
Shellx over CL view when SHELLX_LT_COL is set.
95558 204122 Title: The Face location of angle-bar is strange with SIDE(AFT) in 3D View.
Symptoms: When presenting a planar panel stiffener in 3D generated along a
curve on the negative plate side, the flange is misplaced.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the flange will be presented at the correct place.
The error is only in the picture. The model is correct.

Diagrams:

Incident Issue Description


Number Number
94803 202612 Title: Bad propagation of PSPEC when changing it in a SCPLIN.
Symptoms: Propagate pipline properties gives nullref for scfitt
Previous/Known workaround: perform manual spec search on this fitting.
Solution: Auto Spec Search algorithm has been fixed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 242 of 517
Product Release Letter
Engineering:

Incident Issue Description


Number Number
94494 201969 Title: Compare/Update: doesn’t find any element to compare if there is
distributed attribute in rules
Symptoms: Update is not creating missing XPITEMs
Previous/Known workaround: N/A
Solution: Compare/Update handles the missing XPITEMs and creates them if
needed.

Pipe Fabrication:

Incident Issue Description


Number Number
57563 97194 Title: Cut Pipe Lengths on Fabrication Iso containing Mitred Bends is now correct
Symptoms: Cut Pipe Length on Fabrication Iso containing Mitred Bend was not
correct.
Previous/Known workaround: None
Solution: Cut pipe lengths and centre-line lengths on Fabrication Isometrics
containing Mitre Bends are now correct. Bend segments appear in the cut pipe
list on the Isometrics with their correct cut lengths and a comment 'MTB
SEGMENT'.
60787 107910 Title: The Modify Welds form has limited functionality and incorrect results.
Symptoms:
Previous/Known workaround: None
Solution: ModifyWelds form has been updated to show shop, field, site options
and also to choose the spec based on the option selected.
63530 116359 Title: PF - Modify Spool Form Functions Not Interrupted
Symptoms: NA
Previous/Known workaround: NA
Solution: Introduced two methods to check for active forms and active
functionalities which throws an interruption message when user tries to interrupt a
active functionality.
72233 147089 Title: The Highlighting option from the Weld Handling form does not work
completely.
Symptoms:
Previous/Known workaround: None
Solution: In case of slip-on flange, both the Tube and Flange are being
highlighted based on Fix.
75857 157504 Title: While running the Weld Handling for Creating Weld at various location if the
Pipe Consist of different Spec Component the Weld is Created with the Spec of
Pipe and not Component which results out as Spec Break at every interval
Symptoms:
Previous/
Previous/Known workaround: None
Solution: Based on the status of of CheckBox labelled 'If component is Out of
Spec, use the same source' in Weld Gap Config form, the spec has been taken
from the Component to assign weld.
75919 158234 Title: Weld Creation without Pipe Cutlength Split
Symptoms: Pipe is split into spools and pipe pieces by an off-line weld.
Previous/Known workaround: Not known
Solution: With this fix the pipe is no longer split into pipe pieces by an off-line
weld.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 243 of 517
Product Release Letter
Incident Issue Description
Number Number
86502 184584 Title: Pipe Spool Drawing Form - Preview is Poor
Symptoms:
Previous/Known workaround:
Solution: This fix should make the preview a little more reliable and replace the
old plot file format. By using a PDF viewer all of the print and print preview
options are now available and remove the need for the old PDMS plot viewer.
The old preview showed PDMS plot files (.plt) which didn't support truetype fonts
so the preview files were incomplete resulting in this defect. This fix addresses
the plot file problem in PDMS by producing PDF files and replacing the plot file
viewer with the standard PDF viewer.
In Marine, the output is the same as it was, because Marine Drafting produces
TIFF files rather than PDF. Tiff files are viewed using Windows Photo Viewer.
In both Marine and Plant products the plot files are now placed in a directory
named by the spool drawing creation form and the old PDMSUSER/Preview
directory no longer exists.
Note1: To view PDF files, a suitable PDF viewer must be installed if it is not
already present and this must be able to open PDF files by double clicking on it.
Note2: A problem with PDF viewers is that the user cannot overwrite a PDF file
which is already open so the preview mechanism makes a copy of the main plot
file and puts it into a preview directory in the PDMSWK area. The situation of
having multiple copies of the same file open still exists so the user may notice a
version number in the file name of the PDF viewer.
This should only exist if multiple previews of the same file are open at once.
Note3: This version replaces the right click menu for Preview Drawing with a tick
box on the form itself. this makes Preview easier to switch on and off.
86515 184620 Title: Wrong LSTU is being used for welds created
Symptoms: The wrong LSTU was being selected for welds
Previous/Known workaround: Set the LSTU manually
Solution: We now check the LSTU of the component the weld is for and use that
LSTU for the weld.
86519 184645 Title: LSTU is unset for certain welds
Symptoms: LSTU was not being set for some welds during weld creation
Previous/Known workaround: Set the LSTU manually.
Solution: We now select the LSTU based on the component that the weld was
created for.
87265 188374 Title: Weld Gaps on Branch tees
Symptoms: NA
Previous/Known workaround: NA
Solution: Added a condition for tee when the arrive and leave positions of tube
are in reverse order, so that weld will be created.
89762 192248 Title: Cannot Create a Spool Limit Using a Weld at P3 of Tee.
Symptoms:
Previous/Known workaround:
Solution: This issue is fixed by providing restriction for picking tube, Now we can
only pick components for adding or removing spool limit.
90643 194373 Title: ATTAs - SPKBRK True Creates Too Many Pipe Pieces
Symptoms: Setting SPKBRK true on an atta created too many pipe pieces
Previous/Known workaround: N/A
Solution: Check to see if the SPKBRK attribute is changed on an ATTA and if so
we do not create additional pipe pieces.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 244 of 517
Product Release Letter
Incident Issue Description
Number Number
91234 196097 Title: Weld handling uses specific 'STYP' values rather than reading them from
the backstage
Symptoms: Weld handling was set up to only use 'hardcoded' values for the
STYPs rather than reading them from the defaults set up in Pipe Fabrication
Previous/Known workaround: None
Solution: We now check the STYP each of the weld types from the backstage
and attempt to select a weld based on that STYP rather than the 'hardcoded'
value.
91992 197633 Title: Pipe Fabrication, When adding user feed, status for a validated pipe is not
reset
Symptoms: None
Previous/Known workaround: None
Solution: Invalidating pipe pieces of that particular pipe when feed excess
changes between two components (Especially Bends).
92490 198389 Title: Welds are not created for TESO elements that have LOFF set to TRUE
Symptoms: Welds are not create for TESO elements that have LOFF set to
TRUE
Previous/Known workaround: Create welds manually
Solution: We were preventing this for some reason in the code. We have now
removed the code for this case so that welds are created normally.
92494 198400 Title: Piping - Cannot Create NSBC On Pipe with Welds
Symptoms: None standard branch connections failed on branches with
components with unset lstu.
Previous/Known workaround: set the lstu and try again
Solution: Now the weld handling select lstu every time and the pipe intersection
object handles no lstu correctly.
93751 200324 Title: Pipe Fabrication, Mutiple Spools - wrong feedback to user when "Create..."
Symptoms: The highlight os the spool limits is incorrect, spool limits are not
considered
Previous/Known workaround:
Solution: The highlighting of the spool limits selected while adding to the spool
drawing needs to be fixed by considering the attributes say AsfBreak, LsfBreak
along with CsfBreak.
Code change has been made to the pfevaluatespoolmember.pmlobj in
highlighting the selected spool limits.
93752 200331 Title: Pipe fabrication, adding spool limits (no weld) - ghost limit may be
displayed
Symptoms: when user adds spool limit a ghost spool limit is being displayed at
the other end of the tubi. Please check the attached video for the better
understanding of the scenarion.
Previous/Known workaround:
Solution: Code has been corrected in the method "ShowSpoollimits" of
pfModifySpool.pmlfrm to avoid adding the spool limit at the incorrect place
(appearing of the "ghost spool limit").
93968 200746 Title: Modify Spool Form - Aid Behaviour
Symptoms: NA
Previous/Known workaround: NA
Solution: removed the lines of code that unenhances and clear aids of previous
functionalities when set machine Insertion Direction is selected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 245 of 517
Product Release Letter
Incident Issue Description
Number Number
94077 200961 Title: Errors whilst opening Weld Handling form as welds were not able to be
renamed
Symptoms: Welds that are created are named according to the weld number
that they are assigned (unless the autonaming rule states otherwise). In some
cases customers were then changing the number of these welds manually
leading to conflicts in assigning new names andweld numbers.
Previous/Known workaround: None
Solution: We now no longer attempt to rename/renumber welds that have
already been assigned a name/number. This is to prevent duplicate names/weld
numbers being used.
94315 201438 Title: Unable to determine which Galvanization Tank was used to check certain
elements
Symptoms: Using the Galvanization tank check form, a user is unable to tell
which tank was used to check the element.
Previous/Known workaround: None
Solution: We have created a new attribute that stores what tank was used to
check the element. This is then shown on the form so the user is aware which
tank was used to check the element.
94398 201753 Title: No warning displayed to a user if they attempt to assign an excess to an
element that already has an excess
Symptoms: A user can easily override any excess that are currently set on a
component.
Previous/Known workaround: None
Solution: We have added a warning so that when the user attempts to change
the excess on a component using the appware that if one already exists they will
override the current setting.
94497 201974 Title: The Search Within option on the Multiple Spool form are not working
correctly
Symptoms: While picking elements for adding to spool, elements from different
multiple pipes are allowed for picking eventhough the "Search Within" option is
set to "pipe".
Previous/Known workaround:
Solution:
1. In the "Multiple Spool" form The "Search Within" option box is grayed out as
soon as the user selects spool functions "Add to Spool Drawing by Pick" and
"Remove from Spool Drawing by Pick". The same "Search Within" will be become
active after the Addition or removing of spool functions are completed.
2. The Piperefs, branRefs,etc are nullified after the merging of selected elements
to Spools, hence they can be freshly initialised for every new Spool function.
3. pfsplitmergespools.pmlfrm and pfspooler.pmlobj are modified.
94640 202243 Title: Some fitting to fitting welds will not be created using the 'by pick option'
Symptoms: When using the 'create welds by pick' option, some fitting to fitting
welds would not be created.
Previous/Known workaround: Create welds manually
Solution: These cases were never taken into account when using the 'create
welds by pick' option. As a result we have had to add these cases to 'create
welds by pick' functionality.
94693 202372 Title: Finished Lengths were being calculated incorrectly (1mm out per bend)
Symptoms: The bend length of bends are being calculated incorrectly. This
leads to the finished lengths being off by 1mm per bend in the pipe that is being
checked.
Previous/Known workaround: None
Solution: We now use the FitLen attribute to determine the length of a bend.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 246 of 517
Product Release Letter
Incident Issue Description
Number Number
94698 202383 Title: Fabrication Check - Incorrect Bend Program with Loose Excess
Symptoms: A problem occurs with the Length Inside/Length Outside/Bending
Act values when the spool has a Loose component and requires a 50mm excess.
Previous/Known workaround:
Solution: ArriveExcess is already added to the ArriveTubeLength in
InitializeCheckResult of PFFabricationMachineManager
LeaveExcess is already added to the LeaveTubeLength in InitializeCheckResult
of PFFabricationMachineManager
Hence while calculating the Machine Outside Length in the CheckInsertionLength
in PFFabricationMachineManager, the ArriveExcess/LeaveExcess are excluded.
Also while calculating the bendingActivities, the feed is calculated by excluding
ArriveExcess/LeaveExcess.
95174 203333 Title: We don't handle expressions being used for the UWEI attribute when
calculating the FTUB weight of a pipe end
Symptoms: Some customers use expressions to calculate the UWEI attribute
when calculating the FTUB weight for a pipe end. As a result this would fail and
the incorrect weight would be supplied.
Previous/Known workaround: Use actual values rather than expressions
Solution: We now parse the expressions correctly and they can now be used in
the calculation process. Additionally, other changes are required to update the
piping specs, property database and the FTUB dataset in order for these weights
of a pipe end to be calculated correctly. These macros should have been
released along with the fix and instructions for running them should have been
included.

Outfitting:

Incident Issue Description


Number Number
75778, 156899, Title: Isodraft - Cut Pipe Lengths on Fabrication Iso containing Mitred Bends
66778 157508 is now correct
Symptoms: Cut Pipe Length on Fabrication Iso containing Mitred Bend was not
correct.
Previous/Known workaround: None
Solution: Cut pipe lengths and centre-line lengths on Fabrication Isometrics
containing Mitre Bends are now correct. Bend segments appear in the cut pipe
list on the Isometrics with their correct cut lengths and a comment 'MTB
SEGMENT'.
77851 162680 Title: Isodraft – PTAPs numbered for a Spool Drawing even though they are not
shown in material list.
Symptoms: PTAPs cause a gap in part numbering on Spool Drawing isometric.
Previous/Known workaround: None.
Solution: Do not number PTAPs.
90435 193988 Title: Add Structure element by ADD ONLY then next ADD ONLY will not work
Symptoms: This only happens if the framework gets added preventing structural
elements below from being added
Previous/Known workaround: Remove framework from the drawlist
Solution: Check if framework is a valid element to add in add only.
94432 201872 Title: HVAC - The PCRFA not working as expected for HVAC parts
Symptoms: Bran members in more than one spool
Previous/Known workaround: None
Solution: Now fixed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 247 of 517
Product Release Letter
Incident Issue Description
Number Number
96407 206417 Title: Design - Handling errors in defaults file cat-pipetablecodes.pmldat
Symptoms: If the defaults file does not contain the expected global variable
definitions, entry into Paragon can abort.
Previous/Known workaround: Use the standard default file and edit it to include
the reuqired global definitions
Solution: Add error handling to catpipetablecodes.pmlobj.

12.1.SP4.33

Initial Design:

Incident Issue Description


Number Number
91982 197613 Title: Calc crashing on importing CXML-file
Symptoms: When omitting update of compartment when jusing Import geometry
file (cxml) application crashed.
Previous/Known workaround: Use the other import method.
Solution: A code change is applied to correct the error.

Planar Hull:

Incident Issue Description


Number Number
68596 135729 Title: Symbolic View Creation, Select tab
Symptoms: The Select tab in Symbolic View Creation form is always reset to it's
initial state.
Previous/Known workaround: Manually change in the tab to correct values.
Solution: Select tab wil not be reset after each time a symbolic view has been
created.
70640 142274 Title: Excess in the Bracket
Symptoms: Excess is not possible to given on a standard bracket.
Previous/Known workaround: Excess is possible to give on Bracket Panels.
Solution: Excess on standard brackets are implemented.
92833 198873 Title: Clip hole of S-side is not display on the 3D View.
Symptoms: Generating a clip with holes in a symmetrical planar panel, the holes
in the clip is not displayed in 3D views on SB side.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so hole will be displayed in reflected collar plates. The collar
plate must be recreated to get correct volume.
92834 198874 Title: Bracket hole of S-side is not display on the 3D View.
Symptoms: Generating a bracket with holes in a symmetrical planar panel, the
holes in the bracket is not displayed in 3D views on SB side.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so hole will be displayed in reflected bracket.
The bracket must be recreated to get correct volume.
93622 200243 Title: Planar Hull, SB panel - scheme not correct stored
Symptoms: If giving XMI, ZMI, XMA,YMA and ZMA in a point statement (for
intersection with surface), all the MAX keywords is removed when the panel is
saved.
Previous/Known workaround: Either give also a YMI or skip one of teh MAX
values.
Solution: Corrected so any combination of MIN and MAX can be given.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 248 of 517
Product Release Letter
Incident Issue Description
Number Number
93044 200311 Title: Add function for bevel code search
Symptoms: Search function in Bevel Selection form only search for bevel
names, not codes.
Previous/Known workaround: No known workaround exists.
Solution: The search function has been extended in a way that if the string in the
search field is not found among the bevel names, it will also try to find it in the list
of bevel codes.
93913 200672 Title: Radius RA added to bracket statement by system after panel recreate
cause problems
Symptoms: Add a bracket as a free position, save and apply. After Panel
Recreate, the thickness is also presented in the schema as RA=<thickn>. This
bracket cannot then be run through in the schema.
Previous/Known workaround: Manually remove the RA kayword in the schema
line.
Solution: Corrected. RA will not appear as the thickness in the schema line.
93945 200695 Title: Problem not to display the folded flange in 3D View to be defined at the
panel bracket
Symptoms: The folded flange of a Panel Bracket is not displayed in the 3D
canvas view and is not detected for clashing.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the foded flange on Panel Brackets are included in the
3D canvas view and is also detected for clashing.
94093 200989 Title: Specification of Decimal point for Thickness.
Symptoms: The material thickness in planar plates is affected by the default
NO_OF_COORD_DEC.
Previous/Known workaround: no known workaround exsists.
Solution: This is now changed so the number of decimals for the plate thickness
is not affected by NO_OF_COORD_DEC. Instead, the maximum number of
decimals in the material is set to 3 decimals.

Curved Hull:

Incident Issue Description


Number Number
67923 133324 Title: Excess info is not coming in curved panel view for SB side
Symptoms: Creating a Curved Panel View for a curved Panel that is valid SB
only, will not present excess info in the resulting view.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so Excess information is presented also on curved Panel
views for SB only panels.
80263 171003 Title: Excess info is not coming in curved panel view for SB side
Symptoms: Creating a Curved Panel View for a curved Panel that is valid SB
only, will not present excess info in the resulting view.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so Excess information is presented also on curved Panel
views for SB only panels.
88631 189647 Title: Old suffix in name when new default surface is selected.
Symptoms: When e.g. creating seams, in the form, the old suffix is always
shown also when new surface has been selected.
Previous/Known workaround: Manually change the suffix for the seam.
Solution: If the previous given name is in the same surface, the name remains in
the Name field. If surface has been changed, the new suffix will be inserted in the
Name field.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 249 of 517
Product Release Letter
Incident Issue Description
Number Number
91925 197533 Title: "old" CPLATE cause crash. New CPLATE with same CSEAM is OK.
Symptoms: When recreating seams and then recreating shell plates, the system
responds with eror 1005 and in some cases hangs.
Previous/Known workaround: After recreation of the seams, activate the plate
and the curved panel that the plate belongs to. Do recreate twice.
Solution: Problem with recreation of a shell plate has been resolved.
93131 199408 Title: 12.1.SP4.31, Modify Shell Stiffeners as Group, Shrinkage value not
modified by user but changed by program
Symptoms: The shrinkage is not updated properly but changed by the program.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the shrinkage value is not
changed when some other values are changed.
93211, 199518, Title: Modify Shell Stiffener group: material from menu is applied for the first
93212 199522 stiffener only
Symptoms: Modify Shell Stiffener group: Modification of material from menu is
applied for the first stiffener in selection only.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that modification of material from
menu is applied to all stiffeners.
93218, 199525, Title: Modify Shell Stiffener group: Impossible to change an endcut with params
93362 199678 to an endcut without params
Symptoms: See Title.
Previous/Known workaround: Manually remove/change parameters in the
form.
Solution: It is now possible to change an endcut with parameters to an endcut
without parameters when several shell stiffeners are selected.
93223 199529 Title: Bad highlighting of properties of side specific plates in shell expansion
views on SB
Symptoms: Indication a SB specific plate (or over CL plate) in a ShellX view, is
not highlighet.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so plates will be highlighted when indicated for modification.
Note that already created ShellX views must be recreated.
93959 200713 Title: Recreating a group of shell plates – Error messages shall be improved
Symptoms: Error messages from shell plate development does not give the
name which plate that fails.
Previous/Known workaround: No known workaround.
Solution: Messages are updated to also give the current plate name.
95102 203218 Title: Error 304 occurs in Curved Hull after "Clean Workspace"
Symptoms: In Curved Hull error 304 is often set after Recreate of a CHM object.
Previous/Known workaround: Do not use Clean workspace. This is only in
Curved Hull Modeling. Using Structural Design is not an issue.
Solution: Error 304 is often set after a recreate of a Curved Panel is done and
then Clean Workspace has been done.
The Clean Workspace cleand out one internal important object.
This object now remains in memory and the error will not be set for this workflow.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 250 of 517
Product Release Letter
Hull Structural Design:

Incident Issue Description


Number Number
92569 198723 Title: FEM Interface Filter Addition to sort FEMWLD and Blocks only
Symptoms: Missing filter for Finite Element Model in Design Explorer.
Previous/Known workaround: No known workaround exists.
Solution: A new filter "Finite Element Model" has been added to the Design
Explorer that allows the user to show FEMWLD elements and their descendants
only.

Hull Production:

Incident Issue Description


Number Number
93757 200336 Title: Outputted genfile contents are mismatch with based model.
Symptoms: Fictive stiffener marking on symmetrical knuckled panels gets wrong
id in the generic file on the SB side plate.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that marking references are correct also for the reflected
symmetrical knuckled panel part.

Hull Nesting:

Incident Issue Description


Number Number
90229 193451 Title: Precision of the Raw Plate Thickness
Symptoms: Current version of nesting cannot read from catalogue RawPla with
thicknesses as 11.11mm, 9.53mm. It can read only rounded up to one decimal
digit 11.1mm, 9.5mm.
Previous/Known workaround: No known workaround exists.
Solution: Number of decimals for Raw Plate Thinckness has been extended to 2
decimals.
90437 193836 Title: Auto nest plug in do not handle labels added true 'part viewer' function.
Symptoms: When using the plugin option Auto Nest, the labels added through
Part Viewer is not handled.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the lables are handled via Auto Nest plug in.

Marine Drafting:

Incident Issue Description


Number Number
76980 160339 Title: Color Settings for Some Hull Components are Missing for Symbolic Views
Symptoms: Welded Flanges are not possible to give colours via SVIEW_LT_COL
Previous/Known workaround: No known workaround exists.
Solution: FLA_ABUT_TS and FLA_ABUT_OS and FLA_INT are now
implemeted.
87313 186235 Title: View centre moved so far when you add a Hull Note.
Symptoms: When creating a Hull Note for the first time, the view center is moved
far away from the actual view.
Previous/Known workaround: Manually zoom back to the view.
Solution: Corrected so view center will not change when indicating for the note.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 251 of 517
Product Release Letter
Incident Issue Description
Number Number
88052 188578 Title: Default Option Define/Function Update–Symbolic View
Symptoms: Slicing on a Hull Symbolic View (HSV) is not updating the Depth
Before/Behind.
Previous/Known workaround: Manually modify the depth in the HSV form.
Solution: When doing Slice on a HVS, the depth will be updated for the view.
90136 193091 Title: Can not use Romans font in specific drawing
Symptoms: Problem with drawing that for some reason use the font "RomanS"
with the font name in capital letters, "ROMANS". This caused some confusion
when later using font name "RomanS".
Previous/Known workaround: No known workaround exists.
Solution: Improvements have been made to handle this difference in case. Using
“Tools\Inspect Drawing\Intergrity check”, the internal true type font table in the
drawing will be updated.
90856 194884 Title: Can not perform the print preview for drawing which size is over A0
Symptoms: Print Preview takes very long time and finaly aborts the system for
drawings larger than A0.
Previous/Known workaround: No known workaround exists.
Solution: Print preview now works for all page sizes.
92644 198624 Title: View > Grid > Visible > halt (without opening drawing)
Symptoms: If no drawing is active, when using the function Grid, the system
aborts.
Previous/Known workaround: Make sure an active drawing exists.
Solution: The menu option "Grid->Visible" can be selected only when there is a
drawing. When no drawing opened the option is greyed out.
92837 198877 Title: When using Parallel curve,Fatal Error occurs on imported drawing.
Symptoms: Using Parallel Curve, the system aborts.
Previous/Known workaround: No known workaround exists.
Solution: The problem is for very large curves with many segments. The issue
with the system abortion has been resolved.
93754 200591 Title: The drawing type does not show on the list for can store the subpicture.
Symptoms: When save the subpicture by Tools > Subpicture > Save, the
drawing type does not show on the list.
Previous/Known workaround: No known workaround exists.
Solution: The issue regarding subpicture type not being shown in drawing type
field in save subpicture dialog has been solved.

Diagrams:

Incident Issue Description


Number Number
72851 148806 Title: Borearray is not set for CAPs
Symptoms: When attaching CAP element to another line part its borearray is not
set. Also refit doesn't work and CAP stays not dimensioned. This is a problem
when not using specifictions.
Previous/Known workaround: Set borearray manualy.
Solution: The problem has been solved and dimensioning works properly for
CAPs as well.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 252 of 517
Product Release Letter
Mechanical Equipment Interface (MEI):

Incident Issue Description


Number Number
90857, 194886, Title: Arc tolerance not considered in exported model.
93225 199536 Symptoms: The presentation of doubling plates after exporting them into
Step203 is bad. The doubling references to a Hole and Is facetted. The hole itself
is a manhole and will be resented with arcs.
Previous/Known workaround: No known workaround exists.
Solution: The method to present doubling plates in 3D and export them has
been improved.

Pipe Fabrication:

Incident Issue Description


Number Number
59828 104657 Title: Modelling Consistency Checks Errors For Non-standard Tee Config.
Symptoms:
Previous/Known workaround: None
Solution: this issue is fixed by introducing the conditional statement for TEE joint
Arrive and Leave points in the code.
63578 116477 Title: Galvinization Tank Check Results Not Stored
Symptoms: NA
Previous/Known workaround: None
Solution: Updated program to keep the latest result until restarting a module.
91438 196548 Title: Pipe Fabrication: Spool type is SHOP even when a loose components
excess is set
Symptoms: The spool type of a PSPOOL element does not change when
components of the spool should make the spool type change
Previous/Known workaround: Set the spool type manually to what it should be
Solution: We now store if the spool type has been previously changed once
already, and if so now inform the user about additional changes to the spool.
Giving them the option to either use the spool type currently set or override it with
the new value.
92067 197742 Title: Pipe Fabrication - Part numbering is not reliable for the isometrics
Symptoms: None
Previous/Known workaround: None
Solution: PTNT generated for FTUB of Slanted and Threaded Pipe Ends is
assigned to them as PTNO also. Code modified accordingly and now we have
reliable part numbers in isometrics.

Outfitting:

Incident Issue Description


Number Number
65162 129674 Title: Isodraft - Symbol keys for weld -isopreview
Symptoms: User would like the option to specify which symbol is used to
represent a Field Socket Weld.
Previous/Known workaround: None
Solution: Supply an option to specify which symbol is used to represent a Field
Socket Weld.
75862 157302 Title: Cannot create isometric for Spool Drawing of a Mitred Bend without arrive
or leave tube.
Symptoms: Cannot create isometric because Mitred Bend is not numbered.
Previous/Known workaround: None.
Solution: Number a Mitred Bend without leave or arrive tube.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 253 of 517
Product Release Letter
Incident Issue Description
Number Number
85969 183381 Title: Piping - New assembly not mainting a BRANCH connection to a TEE
Symptoms: NA
Previous/Known workaround: NA
Solution: A change has been made with respect to assemblies with TEE
connections. In case the the branch is connected to the tee, The connections has
to be restored. A sequence of commands is now implemented in the code to
restore this connections.
86548 184783 Title: Piping - Incorrect part selection while inserting pipe assemblies
Symptoms: NA
Previous/Known workaround: NA
Solution: [PU 23.04.2016]
A confirm alert is now introduced for the user incase if there is only one choice
and it doesnt matches the stype.
86616 185468 Title: Piping - Wrong TUBE selected when placing an ASSEMBLY
Symptoms:
Previous/Known workaround:
Solution: Code written by Tony for Defect No 194618 (SI 90742) resolves the
issue for this defect also. Now the the TUBI are created as per the current pipe
spec and not as per the assembly pipe spec.
88098 188436 Title: Visualisation - The colour of highlight for selected model in wire mode is
strange - DX Wireframe colour incorrect after selection.
Symptoms: Wireframe selection was not respecting the chosen selection colour.
Previous/Known workaround: None.
Solution: Fixed to respect the selection colour.
88524 189746 Title: Text items with large CSPAC export incorrectly to DXF/DWG
Symptoms: The spacing is even larger in the DXF/DWG
Previous/Known workaround: N/A
Solution: The formula for converting PDMS CSPAC to AUTOCAD \T values has
been revised and the result is now a better match.
NOTE: Where the value of CSPAC is negative, the \T value in the exported file is
correct, but AutoCAD will not squeeze the characters together after all the inter-
character white space has been used. Typically this white-space is 15% of the
character size, so values of CSPAC below -.15 appear the same as exported text
with a CSPAC of -.15.
88962 190370 Title: Design - XYZ labels are not shown in Model Editor
Symptoms: When rotating the ME handles, the directional labels are not shown
always.
Previous/Known workaround: No known.
Solution: Fixed.
89963 192702 Title: Design - Problem with collect exactly and gtroom with stwall elements
Symptoms: Failed to allow for JUSL setting.
Previous/Known workaround: Set JUSL to NA & move SCTN.
Solution: Now fixed.
90835 195345 Title: Visualisation - Outfit-Create-From Standard Model Library-
SGL_Delete_Segment message at Console
Symptoms: When creating a Standard Model Library Item, an SGL error was appearing
in the console window.The error was SGL_Delete_Segment: Hash table fault
Previous/Known workaround: No know workaround
Solution: Change made to sgl_delete_segment to pass in the global structure
store. No error now occurs.
91179 195741 Title: Isodraft - NSBC detail plot is added when NSBCOFF option is used.
Symptoms: NSBC detail plot is added.
Previous/Known workaround: Delete detail plot file.
Solution: NSBCOFF to switch off NSBC Detail Plot addition.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 254 of 517
Product Release Letter
Incident Issue Description
Number Number
92068 197914 Title: Design - Validation of ship grid frame numbers
Symptoms: Range check fails if frame numbers increase along -X axis.
Previous/Known workaround: None
Solution: Validation allows frame number to increase in +X and –X.
81343 198706 Title: Isodraft - SHOP Weld cause incorrect dimension value
Symptoms: SHOP Weld with length causes incorrect dimension value
Previous/Known workaround: None
Solution: If Weld preceded by a flange, then length already added in!
92832 199421 Title: Draft - Complicated OUTL export incorrectly to DXF
Symptoms: Outlines containing many segments with mixture of bulged &
unbulged VERTices export distorted
Previous/Known workaround: N/A
Solution: Simplified handling of bulges and these complex OUTL now export
correctly.
93613 200149 Title: Search now takes into account STEX RTEX and TTEX attributes
Symptoms: The search ignored the attributes of ITYP 10 for SDTE
Previous/Known workaround: Use filters in collection utlity
Solution: Search now takes into account STEX RTEX and TTEX attributes.
200357 Title: Isodraft - ALS Licensing - "other" licenses being taken by applications
Symptoms: VNET license being checked out needlessly.
Previous/Known workaround: None
Solution: Only check out a VNET license if HYPERPLANT is 'ON'.
93836, 200542, Title: Exports to DXF/DWG contain both raw and interpreted intelligent text
94576 202097 (usually on top of each other) when such text is used in SYMB.
Symptoms:
Previous/Known workaround: N/A
Solution: Export only exports top-level text (i.e. the expanded intelligent text) and
not the raw (unexpanded) text from the template of the SYMB.
93831 200549 Title: Design - User autoname options
Symptoms: User cannot locally switch on/off autonaming rules since recent
autoname administration enhancement.
Previous/Known workaround: Copy complete system naming rules file to user
directory.
Solution: Users local autoname options combined with system autoname rules.
93402 200750 Title: Design - Marine Copy/Mirror reverted to original behaviour
Symptoms: Copy elements created under a different owning element in some
cases
Previous/Known workaround: Use standard copy mirror function rather than
the Marine add-on function.
Solution: Reverted Marine copy/mirror to original behaviour.
94943 202899 Title: Customisation and Common Framework - Fatal error when using EDG.
Symptoms: Fatal error when using EDG.
Previous/Known workaround: Avoid this action.
Solution: Fixed graphical interaction application code.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 255 of 517
Product Release Letter
12.1.SP4.32

Planar Hull:

Incident Issue Description


Number Number
42878 69694 Title: Planar Hull FRP Laminate options (Flange)
Symptoms: When creating a flange in Planar Hull, the option for FRP is
available. It should not be available unless FRP is active.
Previous/Known workaround: No known workaround exists.
Solution: The FRP option is no longer available when creating a flange in Planar
Hull, unless FRP is active.
90670 194443, Title: Problem for the given position number to disappear in Flange statement
195068 wizard
Symptoms: The field of a given position number for a welded flange is in the
Statement Wizard always blank.
Previous/Known workaround: No known workaround exists.
Solution: The position number will now be handled properly when modifing a
flange.
90876 194973 Title: PROF TYPE 60, round bar as flange, in hole weight problem
Symptoms: Hull Tools --> PPI Hull --> Weight and COG, the system gives fatal
error when using a round bar (type 60) as a flange in a hole.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that WCOG works and delivers a
drawing.
91828 197353 Title: Decimal Places settings will be disabled by the value of the Point definition.
Symptoms: for topological point offset (e.g. P2+12), the number of decimals is
restricted to two decimals.
Previous/Known workaround: No known workaround exists.
Solution: Changed to maximum number of decimals allowed for topological point
offset is 5 decimals.

Curved Hull:

Incident Issue Description


Number Number
56896 95874 Title: Curved Hull, the show definition window is too small
Symptoms: The window presented when showing definition of a curved hull
object is in a fixed format. Sometimes all data is not fit into the window and tehn it
would be good to be able to resize the window.
Previous/Known workaround: No known workaround.
Solution: Form is now resizable.
90812 194783 Title: ShellX view outside limits of any block does not show shell plate properties
Symptoms: If shell plates are outside all block limitiations, they are not included
in the ShellX Views.
Previous/Known workaround: Add a dummy block that included the whole ship.
Solution: The error is corrected so that when a new SHELLX view is created
also plates that do not belong to a block will be drawn.
91433 196539 Title: Impossible to select shell plates from Curved Panel View
Symptoms: Impossible to select shell plates from Curved Panel View.
Previous/Known workaround: Select shell plates from other view than Curved
Panel View.
Solution: The problem has been solved so that it is possible to select shell plates
from Curved Panel View. This will work for new created views.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 256 of 517
Product Release Letter
Incident Issue Description
Number Number
92499, 198397, Title: ShellX over CL, SB-specific seams disappear after being modified
92607 198561 Symptoms: When modifying a SB specific shell seam, it will disappear from the
ShellX view.
Previous/Known workaround: Recreate the ShellX view when the seam is
saved.
Solution: The problem has been solved so that SB specific seams will not
disappear from the ShellX view.

Hull Production:

Incident Issue Description


Number Number
60627 107439 Title: Enhancement for builtup profiles to present wegith or cog to handle by
wcog.ip
Symptoms: For built up profiles, the weight and cog is always presented
together in the wcog list.
Previous/Known workaround: No known workaround.
Solution: WCOG for web and flange will now be shown on separate lines when
WCOG_SEP_BUILT_PROF is set.
82657 175919 Title: Can not open the link world on Design explorer.
Symptoms: When trying to open the LINKWL world, the system hangs.
Previous/Known workaround: No known workaround exists.
Solution: To minimize the number of link description elements (LNDESC) directly
under the link world element (LINKWL) the LNDESC elements are now placed in
link folders (LNFOLD) according to the usage code of the link description
element.
The pml utility hullDeleteObsolete.pmlfnc has been enhanced to delete links that
do not point to active documents.
91420 196496 Title: Not possible any more to select only curves from a certain surface
Symptoms: In Advanced Selection (Curved Hull), when choosing a specific
surface, all surfaces are handled anyway.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so when specific item is selected, e.g. Seams and specific
surface selected, only the seams for that surface will be in the selection.

Hull Nesting:

Incident Issue Description


Number Number
91547 196792 Title: After Ppanparts with holes, The Start Mark has been moved.
Symptoms: When a planar panel is re-split, the marking starts sometimes has
moved in the nesting.
Previous/Known workaround: Manually move the marking start in the Nesting.
Solution: Corrected so the starts will not be moved.
91763 197175 Title: After import MPLNST via CopyAssist, MPLNST does not open with fatal
error.
Symptoms: Using CopyAssist for Nested plates, when opening the Nesting in
the target project, system aborts.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so nestings transferred via CopyAssist can be correctly
opened in the target project.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 257 of 517
Product Release Letter
Incident Issue Description
Number Number
91885 197435 Title: Bevel&chamfer code(6 digit code) cannot be entered in 2D drawing.
Symptoms: when ini Nesting, creating plate parts from 2D sketch, there is no
possibillity to key in a bevel code. Only selection from menu is available.
Previous/Known workaround: No known workaround exists.
Solution: By pressing the Option button in the Bevel form, the user will be
promted to key in a bevel code.
Any value is acceppted. There is no check if the value enterd is correct. This is
user responsibility.

Marine Drafting:

Incident Issue Description


Number Number
90722 194704 Title: View name which is copied from another view has a problem.
Symptoms: The name of subpicture which is copied from original one is same.
Previous/Known workaround: Manually rename the view after the copy is
created.
Solution: When copying a view (e.g. by Modify->Copy->Subpicture or File-
>Drawing Reference->Exchange/Expand), the new view will get a unique name.
91030 195267 Title: Bad Line Types in ShellX over CL when using SHELLX_LT_COL
Symptoms: Line types are reversed in over CL ShellX views. Outside becomes
insiade and vice verca.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the line types get correct in
Shellx over CL view when SHELLX_LT_COL is set.
91185 195759 Title: Curved Panel Views, End cut symbols sometimes placed badly
Symptoms: Curved Panel Views, End cut symbols sometimes placed badly.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so the end cut symbols are placed
correctly.
91829, 197355, Title: Problem not to get a list of information relevant to the selected geometry
92326 198163 Symptoms: When using the function "Verify Drawing", the sub-picture names are
not included.
This is working in versions prior to 12.1.SP4 Fix30.
Previous/Known workaround: No known workaround exists.
Solution: Corrected to the sub-picture names are included.
200814 Title: Unable to Exit from ‘Select Backing Sheet’ window.
Symptoms: After closing of a drawing and initiate a new drawing, when listing
the backi sheets, there is no way to exit from the list view.
Previous/Known workaround: No know workaround exists.
Solution: Corrected so the Selection/Cancellation work as expected in the
backing sheet list form.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 258 of 517
Product Release Letter
Engineering:

Incident Issue Description


Number Number
86589 184773 Title: Tags - PML Callback from an Extract command in a Global project crashes
with No Current element (Dabacon 538)
Symptoms: Exit with unhandled Dabacon error 538 (No Current element) when
using an Extract Claim command (or similar).
Previous/Known workaround: Disable recording of Local Extract commands in
a Global project - In ADMIN at /*MS, set TRSETL FALSE; default is True.
Solution: Ensure that Savework on the Transaction database initialises its
current element. This protects against Callbacks on SAVEWORK.

Pipe Fabrication:

59831 104674 Title: Modelling Consistency Needs to Report Missing Nominal Bores
Symptoms: NA
Previous/Known workaround: NA
Solution: When we check for Main distance and branch distance in
pfWeldGapCheck.pmlobj file we are trying to retrieve minimum distance for Main
bore and branch bore. If minimum distance is not set we are throwing an error
"This Branch includes nominal bores that have not been included on the
Consistency Check Configuration form. Please inform your Administrator" for
both main bore and branch bore.
75568 156065 Title: Mess when collecting/removing SPLDRG members
Symptoms: None
Previous/Known workaround: None
Solution: Search within different hierarchys option is implemented with default
PIPE option. Mess resolved.
75753 156777 Title: Multiple Spool: Add and Remove cannot be used together
Symptoms: None
Previous/Known workaround: None
Solution: The buttons are now working independently. When one button is used
the other is greyed out (inactive).
76338 158438 Title: Isometric production stops due to FTUB not having a weight
Symptoms: Cannot get NWEI of slanted end FTUB.
Previous/Known workaround: None.
Solution: A catalogue update needs to be applied to enable the ftub weights to
be derived using a design parameter.
77088 160635 Title: PIPE kept validated and released, even model is changed!
Symptoms: NA
Previous/Known workaround: NA
Solution: Checking for NeedSpoolings count greater than zero and invalidating
all pipe pieces of that particular pipe.
74324 164703 Title: Error of Spool Split
Symptoms: NA
Previous/Known workaround: NA
Solution: When there are multiple branches we need to re initialize sequence
number to 0 in LoadSpools method so that when next branch is processed it will
try to retrieve correct element.
79522 168550 Title: setting sloped pipe ends does not maintain LSTU correctly when there are
multiple choice tubes
Symptoms: lstube of a sloped ftub is wrong if the previous component does not
use the default tube
Previous/Known workaround: Change tubes manually.
Solution: The sloped end application now handles tube correctly.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 259 of 517
Product Release Letter
79879 169704 Title: The pipe Fabrication Installation and Fabrication Isometric application was
unable to list multiple sheets per drawing.
Symptoms: Whenever multiple sheets were produced the form could not
preview them.
Previous/Known workaround: None.
Solution: The application now uses the general Isodraft preview facility which is
able to display multiple sheets.
88027 188768 Title: Unable to create a spool break at the branch of a TEE
Symptoms: None
Previous/Known workaround: A work around would be to add a weld with
SHOP = False to the Tee before connecting the branch as this would maintain
connectivity.
Solution: Code modified to assign CSFBREAK as TRUE for TEE and for the
Branch that is connected to tee TSFBREAK as TRUE.
89641 192026 Title: Weld Handling Inconsistencies for Socket Welds
Symptoms: Unable to create socket welds from spec.
Previous/Known workaround: N/A
Solution: Removed the reliance on the spco element being named correctly. We
now choose the spec using the correct STYP which allows us to create socket
welds from spec.
89751 192223 Title: Changes required for the wording of the Fabricated Pipe Ends form.
Symptoms:
Previous/Known workaround: No known workaround.
Solution: Modified the file
PMLLIB\pipefabricationmanager\design\forms\pfFabricationPipeEnd.pml.frm
To provide following corrections.
1. The actual value of the sniped angle is displayed in the Drawing note text in
the place of '{deg} ' in the following default text "Trim pipe end to {deg}".
2. The word 'slanted' replaced by 'sniped' as it is better engineering terminology.
This appears in two places on the form.
89752 192227 Title: Fabricated Pipe Ends - Info Button Does Not Track
Symptoms:
Previous/Known workaround: No known workaround.
Solution: This issue is fixed by making changes in update method for getting the
information of selected pipe.
90644 194378 Title: PF - Modify Spool Form Results in Error on PLAT Element
Symptoms: If any branch of the pipe contains element like PLAT which does not
have lExcess and aExcess attributes, unhandled error pops up and the "Modify
Spool" form will not be loaded.
Previous/Known workaround: Handling the error through an exception handler.
Solution: In the function showEndExcesses of pfModifySpool.pmlfrm lExcess
and aExcess attributes of the elements are being accessed to fix the
arriveboundar and leaveboundary values. Error occurs if the element does not
have the lExcess and aExcess attributes. Error handled by adding an Exception
in the function
.showEndExcesses of pfModifySpool.pmlfrm
where the attributes lExcess and aExcess are being referred.
91436 196542 Title: Doubled informal message when changing spool type within Fabrication
Check form
Symptoms: If the spool type is changed to FITT or SITE from SHOP, informal
messages are added when the pipe is validated and Released. This results in
double informal messages are displayed in the Check Results tab of Fabrication
Check Form
Previous/Known workaround: No known workaround.
Solution: The Check Results of the pipepeice are verified for duplication of
messages before adding informal message.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 260 of 517
Product Release Letter
91992 197633 Title: Pipe Fabrication, When adding user feed, status for a validated pipe is not
reset
Symptoms: None
Previous/Known workaround: None
Solution: Invalidating pipe pieces of that particular pipe when feed excess
changes between two components (Especially Bends).

Outfitting:

55700 93457 Title: Design - Restore View when DB ref no longer exist
Symptoms: Bad error message
Known workaround: N/A
Solution: Missing DB element no longer causes bad error.
57784 97717 Title: HVAC - Could not make an HVAC assembly with a connected branch
when connection point was not P3
Symptoms: System failed to recognise the connected branch.
Known workaround: No easy workaround.
Solution: Issue now fixed.
60360 106546 Title: HVAC - Combining of HVAC spool which have been selected in the list
Symptoms: This is an enhancement.
Previous/Known workaround: Other methods available.
Solution: A new option to "Combine Spools selected in 'HVAC Spools' list".
67806 132242 Title: Database and Data Management - In Tags - List of Valid Values not
displayed in the drop list in the Create Information Window when the UDET type
is unknown.
Symptoms: In Tags - List of Valid Values for a parameter is not displayed in the
drop down list on the first screen of the Create Information Window for a view
based on multiple UDET types.
Known workaround: Suggested work around is to define the attributes with list
of values as optional parameters, navigate to the next screen on the Create
Element Information window - select the type and then return to the first screen
to select the value from the list of values drop down list.
Solution: In Tags - when a view is based on multiple types the list of valid values
for an attribute (defined as parameter) can now be displayed in the drop down list
in on the first screen of the Create Information Window. (The user no longer has
to select the (UDET) type on the second screen and then return to the first to see
that the list of valid values for the optional parameter has been populated).
71628 145514 Title: Customisation - Translucency of primitives not restored after selection
highlight/unhighlight
Symptoms: Translucency of primitives overridden in drawlist not restored after
selection highlight/unhighlight.
Previous/Known workaround: Re-add affected element(s) to the 3D view.
Solution: Restore primitive translucency when element unhighlighted.
71709 147610 Title: Design - Maintain specified drive and name for isometric files.
Symptoms: Isometric files created in user folder with incorrect names.
Previous/Known workaround: None.
Solution: Maintain drive and plot file name if 'Use Drawing name' option is used.
73509 150383 Title: Structures - Mass Properties form
Symptoms: Enhancement to indicate errors and warning in form list.
Previous/Known workaround: No known workaround.
Solution: Highlighting the any USRWEI weight cell in an orange colour
Also coloured any errors in red to make them more noticeable.
Information tooltips also added to tell user why orange or red.
74186 152416 Title: Draft - User Grid Ref Nos are lost when modify any aspect of a GRIDSYS
Symptoms: Modify a GRIDSYS in Design then lost Draft Dimensions and labels.
Previous/Known workaround: Had to re-work draft labels and dimensions.
Solution: Retained Ref Nos when Modifying in Design.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 261 of 517
Product Release Letter
74035 152715 Title: Isodraft - Maintain specified drive and name for isometric files.
Symptoms: Isometric files created in user folder with incorrect names.
Previous/Known workaround: None.
Solution: Maintain drive and plot file name if 'Use Drawing name' option is used.
78146 163820 Title: Design - Isometric not produced for PTAP connection with different bores
on different specs.
Symptoms: Error : (42,64) **** not selected.
Previous/Known workaround: None.
Solution: Use spec of next tube for PTAP 46 record.
85464 166722 Title: Database and Data Management - Fatal error occurs when opening a
project using .NET interface and the selected module is not defined in that
project
Symptoms: Application exits with fatal error "Kerror 6" on attempting to open
project using an undefined module
Previous/Known workaround: Ensure required module is defined in the
project (or that project is properly upgraded to the expected version) in advance.
Solution: Software fix to allow handling of failure to open project.
67020 174540 Title: Structures - To 'Set Selected Panels to Default Spec'
Symptoms: No quick solution to 'Set Selected Panels to Default Spec'.
Previous/Known workaround: Change each Panel individually.
Solution: This is done via a new button on the Steel Utilities Toolbar
(Tooltip 'Set Selected Panels to Default Spec').
82295 175334 Title: Reporting - Report Heading text was not updated for column delete
Symptoms: Wrong column heading given on next report.
Previous/Known workaround: Reset headings manually.
Solution: This has now been resolved.
83020 176548 Title: Design - Add CE button for lock form.
Symptoms: No CE button on Lock form.
Previous/Known workaround: Have to cancel and select from menu each time.
Solution: CE button added.
83061 176643 Title: Structures - Structural Modify Fittings button does not always reselect
actual spref
Symptoms: Modify CE displayed wrong spref in form.
Previous/Known workaround: N/A
Solution: Fixed, and current spref is displayed.
83757 178271 Title: Structures - Mark SJOI in wrong place
Symptoms: MARK SJOI drawn in wrong place if SPREF is nulref.
Previous/Known workaround: Set SPREF?
Solution: Now fixed.
87532 186818 Title: MDS - FT06 ancillary orientation error
Symptoms: Framework ancillaries do not orientate properly with the direction
input in the direction form.
Previous/Known workaround: manual rotation of the ancillary in the mdsFT06
form.
Solution: Now resolved.
196493 Title: Replacement PML file to activate Clash Manager button in PDMS/Outfitting
12.1.SP4
Symptoms: Clash Manager menu not enabled when Clash Manager 14.1
installed.
Previous/Known workaround: N/A
Solution: Clash Manager menu now enabled if Clash Manager 14.1 installed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 262 of 517
Product Release Letter
91666 197028 Title: Design - Dump attributes for Review is crashing when an attribute has '$V'
in its value
Symptoms: Unhandled PML error
Previous/Known workaround: Remove $V from text
Solution: Changed line 434 pmllib/reviewInterface/forms/cdxattdump.pmlfrm
was:
!attrib = !attrib.trim()
now:
!attrib = !attrib.trim().replace('$$V','V').replace('$$v','v')
91974 197603 Title: Customisation - In certain situations the system crashed when some TUBI
was removed from a BRAN
Symptoms: System crash.
Previous/Known workaround: Refresh the Explorer by closing and then
reopening the Branch node.
Solution: The system no longer crashes and the Explorer reflects the state of
the database and graphical view.
91770 197886 Title: Draft - Text with "\T" is not exported correctly to AutoCAD (MTEXT objects)
Symptoms: Any text with a backslash character was not read by AutoCAD
correctly; \T, \Q, \L, \P, \F and some other combinations may cause the text to be
rendered incorrectly.
Previous/Known workaround: Manually double the \ in the text.
Solution: Any / in the raw string are doubled before being written to file.
198029 Title: Draft - 'U' character showing on both the sides of text with Underline
Symptoms: Text surrounded with 'u' instead of being underlined.
Previous/Known workaround: N/A
Solution: %%u flags checked first and handled correctly.

12.1.SP4.31

Assembly Planning:

Incident Issue Description


Number Number
41285 165330 Title: Assembly node name duplication
Symptoms: It is possible to create an assembly with an already existing name.
Previous/Known workaround: No known workaround exists.
Solution: It will still be possible to create assemblies with same names but a
warnign will be presented to the user when Save Work is done.

Initial Design:

Incident Issue Description


Number Number
87775 187606 Title: Surface & Compartment Model Release to Dabacon issue
Symptoms: The performance of releasing Surface & Compartment data to
design is slow.
Previous/Known workaround: None.
Solution: Performance has been dramatically improved.
89357 191393 Title: Weight estimation error, main deck of envelope included twice
Symptoms: Main deck weight added twice to weights
Previous/Known workaround: Not to include main deck separately to weight
estimates, this will not allow user to have specific weight factors for the main deck
and envelope.
Solution: Code change applied to correct error.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 263 of 517
Product Release Letter
Planar Hull:

Incident Issue Description


Number Number
28113 68944 Title: Hull Posno Note problems
Symptoms: Not possible to control all the Hull Position Number check boxes.
User must manually change.
Previous/Known workaround: Manually change the check boxes for the note.
Solution: Additional defaults has been added in order to control the check boxes
in the Hull Position Number function. For more information refer to section
Enhancements above.
52406 86588 Title: Hull Panel disappear in views
Symptoms: Sometimes, new planar panels are not shown in views with hidden
line style type.
Previous/Known workaround: Do recreate on the view and the planar panel will
be included.
Solution: The problem is fixed. The hull model should not disappear when you
update it in Hull Design.
72543 164627 Title: Yard Prqactice for Bevel(inc. Auto) along touched line
Symptoms: Need new bevel types where the nose is calculated along abutting
surface.
Previous/Known workaround: No known workaround.
Solution: For more information refer to section Enhancements above.
83633 177994 Title: How to import to a knuckle panel via Copy Assistant?
Symptoms: Knuckled panels are not handled by Copy Assistant.
Previous/Known workaround: Manually copy the planar panel schemas and
run in the new project.
Solution: A knuckle panel with main- and sub-panels will be treated as one
common entity by Copy Assist.
85007 181089 Title: Symmetrical brackets don't use PPOS & SPOS syntax in Wizard
Symptoms: Wizard don't use PPOS & SPOS syntax for a symmetrical bracket.
Syntax works in case of explicit statement through the scheme.
Previous/Known workaround: Manually change in the schema to get PPOS
and SPOS for the bracket.
Solution: PPOS and SPOS is now handled properly.
89866 192426 For information about this issue refer to section Enhancements above.
90039 192882 Title: One boundary panel ignored by PPI.
Symptoms: Creating a planar panel with only one boundary and adding weld to
the boundary will not go through ppanparts.
Previous/Known workaround: Do not add weld in the planar panel but instead
add it in the nesting process.
Solution: Corrected so ppanparts will handle one boundary panels with
additional weld added.
90188 193263 Title: Clips mirrored over CL when panel is knuckled.
Symptoms: Clips on a knuckled panel on SB side is drawn on PS in teh 3D
canvas.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the clips are not mirrored for a
SB specific knuckled panel.
90224 193952 Title: Panel Store POST trigger executed after Panel Store PRE trigger was
Aborted.
Symptoms: Post trigger should not be executed if Pre trigger aborts but it does
execute anyway.
Previous/Known workaround: No known workaround exits.
Solution: Corrected so if pre-trigger fails, panel will not be stored and post-trigger
will not be executed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 264 of 517
Product Release Letter
Incident Issue Description
Number Number
91007 195185 Title: AutoPosError:if clip has hole, It should be different PosNo to numbering.
Symptoms: AutoPos is not checking if holes are included/different when
comparing.
Previous/Known workaround: No known workaround exists.
Solution: Autopos will check for holes in clips and compare if it is the same
definition.

Curved Hull:

Incident Issue Description


Number Number
60917 108322 Title: Update cstiff as group causes new problems
Symptoms: When more than one Shell Stiffener is acitve then when modify
anything, the first activated stiffeners parameters are copied also to all the other
shell stiffeners.
Previous/Known workaround: Activate only one stiffener at a time.
Solution: When modifying a number of Shell Stiffners, only the modified
parameters will be copied into the whole selection.
89059 190634 Title: Shell stiffeners disappear from shell expansion view over CL after
modification
Symptoms: Shell stiffeners disappear from shell expansion view after modifying
them.
Previous/Known workaround: Recreate the Shell Expansion View after the
modification.
Solution: The problem has been solved so that the stiffeners in a OverCL Shellx
view will not disappear when they are modified.
89527 191694 Title: Update cstiff as group causes new problems
Symptoms: When more than one Shell Stiffener is acitve then when modify
anything, the first activated stiffeners parameters are copied also to all the other
shell stiffeners.
Previous/Known workaround: Activate only one stiffener at the time.
Solution: When modifying a number of Shell Stiffners, only the modified
parameters will be copied into the whole selection.
90398 193788 Title: ShellX, View properties not updated in existing shell expansion views
Symptoms: Recreate view of a ShellX view does not update properties such as
thickness and grade.
Previous/Known workaround: Create a new view with same input.
Solution: The View properties are now updated when shellx views are recreated.
90530 194063 Title: ShellX, View properties, Posno for plate over CL wrong in SB view
Symptoms: Shell plate over CL in ShellX view is not presented with correct
position umber in a view created on SB side. On PS it is correct.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the Shellx View gets correct
posno for a OverCL Plate.
90737 194600 Title: ShellX view over CL, models disappear after Model View-Exchange
Symptoms: All models are removed from the shellX view when invoking the
function Tools -> Model View -> Exchange -> Hull -> From Model .
Previous/Known workaround: Recreate the ShellX view.
Solution: The problem has been solved so that the models will not disappear
after Model View Exchange.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 265 of 517
Product Release Letter
Hull Structural Design:

Incident Issue Description


Number Number
90463 193934 Title: Error at "Number of Frames" in Gentab file
Symptoms: Consecutively numbers from e.g. -27 to 495 is not working. System
respond that there are too many frame numbers.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so consecutively values from -99 to 500 is acceppted as
described in documentation.

Hull Production:

Incident Issue Description


Number Number
71703 145493 Title: Missing marking for Templates
Symptoms: No marking lines on developed plate for bending template.
Previous/Known workaround: None
Solution: Corrected so missing markings on the developed plates for bending
templates are added.
85652 183848 Title: AUTO_SELECT for Auto bevel application with /CUTOUT and /BRIDGE
Symptoms: CUTOUT in bevel does not give any bridges for cutouts.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the CUTOUT in bevel handling will produce bridges in
cutouts when aprropriate according to definition.
87876 187808 Title: Missing marking for Templates
Symptoms: No marking lines on developed plate for bending template.
Previous/Known workaround: No known workaround.
Solution: Corrected so missing markings on the developed plates for bending
templates are added.
88618 189613 Title: Plate direction is strange on Gen.file(viewer).
Symptoms: In some plates, the generic file has the wrong directions marks.
Previous/Known workaround: No known workaround exists.
Solution: Direction marks are corrected.
89426 191485 Title: Unnecessary Profile end angle 90 deg appeared in PPI.
Symptoms: For twisted profiles, the attachment angle indication is not always
correct. The angle for 90 degrees is not necessary to include in the drawing.
Previous/Known workaround: Manuel touchup to remove unnecessary angle
indications in the receipt drawings.
Solution: Diaplaying of knuckle angle corrected.
192210 Title: Jig pillars for PS Knuckle are created for both Port side and starboard side
Symptoms: When making Jig pillars for a side specific knuckled panel, the pillars
are created on both PS and SB.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so only the one side of Jigpillars are created.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 266 of 517
Product Release Letter
Marine Drafting:

Incident Issue Description


Number Number
36531 63392 Title: Default Attribute IgnDUnion:True
Symptoms: Request to set IgnDUnion as True by defaults.
Previous/Known workaround: No known workaround
Solution: New Marine Drafting default keyword "VIEW_IGNORE_DUNION" was
introduced.
It controls the value set to the attribute IGNDUNIO when a view is created.
If VIEW_IGNORE_DUNION is set to “NO” than the IGNDUNIO attribute is set to
FALSE.
“YES” means that the attribute is set to TRUE.
54860 93586 Title: Problem with special characters
Symptoms: Using $- and @-values to fill up the text in drawing form properties
sometimes gives wrong result when special characters are used (e.g. "Ö").
Previous/Known workaround: No known workaround exists.
Solution: Texts containing "special" characters (like "Ö") will be handled correctly
when inserted in form.
72430 147465 Title: Readonly mode does not work at MarAPI
Symptoms: Drawing is claimed when opening as Read Only via API.
Previous/Known workaround: No known workaround exists.
Solution: There is a new marapi function called DwgOpenAsCopy:
DwgOpenAsCopy( String DwgName, String CopyDwgName, Real
CopyDwgType)
Input Arguments:
1. DwgName - Name of drawing to copy and open.
3. CopyDwgName - Name of drawing copy.
4. CopyDwgType - Drawing type of the new copy. Can be give as "DwgType".
Note that "-1" has the meaning "same type as the source drawing".
The function only works for drawings stored in the PADD database (therefore
there is no drawing type argument for the source drawing, it is fully identified by
its name)
(DwgOpenAsCopy is only implemented in MARAPI and not in Vitesse).
73049 149341 Title: 3D Event Point Snapping
Symptoms: Request the ability to customize which 3D Event Points the user is
allowed to select with 3D Event snapping to reduce the risk of errors (e.g. molded
vs. non-molded side of thickness).
Previous/Known workaround: -----
Solution: A new "picking filter" for hull models is implemented. It can be activated
by setting the new drafting default keyword "HULL_PPOINT_PLINE_PICKING" to
"MouldSideOnly". This will reduce the number of p-points and p-lines in the 3D
point modes "event points".

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 267 of 517
Product Release Letter
Incident Issue Description
Number Number
74214 152640 Title: Give explicit target DEPT/REGI in various Marine Drafting functions
Symptoms: Using e.g. Import SDB function in Planar Hull Modelling / Drafting to
Import exported SDB files is working in a way, that the imported SDB will always
be stored by default in general drawing database. There is no way to give explicit
REGI.
Previous/Known workaround: Import drawing and then move it to the correct
REGI by using Save As...
Solution: It is now possible to give explicit REGI in these Marine Drafting
functions:
- New drawing: Interactively + API
- Save As: Interactively + API
- Save Subpicture: Interactively + API
- Copy drawings: Interactive/Batch (already exists) + API
- Copy Assist: New import option: LocationOwner = Automatic / As Source
This option is controlled by a new environment variable, "SBD_OWNING_REGI".
If "AUTO", owner is set automatically as today, if "MANUAL", the user can select
target REGI for the drawings. If a target REGI is not given in this case, then the
drawings are placed automatically.
77687 162144 Title: Default Attribute IgnDUnion:True
Symptoms: Request to set IgnDUnion as True by defaults.
Previous/Known workaround: -----
Solution: New Marine Drafting default keyword "VIEW_IGNORE_DUNION" was
introduced.
It controls the value set to the attribute IGNDUNIO when a view is created.
If VIEW_IGNORE_DUNION is set to “NO” than the IGNDUNIO attribute is set to
FALSE. “YES” means that the attribute is set to TRUE.
78100 163638 Title: Requests on message displaying when referenced model data not existing.
Symptoms: Enhancement request
Previous/Known workaround: -----
Solution: In Tools/Model/Exchange, if the Outfitting model is not found in data
base, a message will be reported to user in the same manner as for hull models
i.e. in the Message Window

- In Right MB -> Navigate -> In Design Explorer, if the model (outfitting or hull) is
not found in data base, a confirmed message will be reported to user.
82407 175721 Title: Printing Vitesse function error (Captured Area)
Symptoms: When printing a specific area in a drawing with vitesse function
using captured area option, the result is different from I expected.
Previous/Known workaround: No known workaround exists.
Solution: When printing a specific area in a drawing with vitesse function using
captured area only contents of that specific area are printed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 268 of 517
Product Release Letter
Incident Issue Description
Number Number
186325 Title: Give explicit target DEPT/REGI in various Marine Drafting functions
Symptoms: Using e.g. Import SDB function in Planar Hull Modelling / Drafting to
Import exported SDB files is working in a way, that the imported SDB will always
be stored by default in general drawing database. There is no way to give explicit
REGI.
Known workaround: Import drawing and then move it to the correct REGI by
using Save As...
Solution: It is now possible to give explicit REGI in these Marine Drafting
functions:
- New drawing: Interactively + API
- Save As: Interactively + API
- Save Subpicture: Interactively + API
- Copy drawings: Interactive/Batch (already exists) + API
- Copy Assist: New import option: LocationOwner = Automatic / As Source
This option is controlled by a new environment variable, "SBD_OWNING_REGI".
If "AUTO", owner is set automatically as today, if "MANUAL", the user can select
target REGI for the drawings. If a target REGI is not given in this case, then the
drawings are placed automatically.
88035 188641 For information about this issue refer to section Enhancements above.
88372 189182 For information about this issue refer to section Enhancements above.
88817 190024 Title: Problem to unset the name of view when insert model in 12.1SP4.x
Symptoms: Views created by Insert Model has no names.
Previous/Known workaround: Manually change the View Name.
Solution: Problem solved by giving the automatically generated views a default
name. The default name will be "VIEW#xxx" where <xxx> is a running number
starting from one.
89346 191567 Title: Dimension > Mold > Indicate Starboard Node -> Dimension Display at Port
side (ref. Test for SBP Pane
Symptoms: When indicating an SB component for Mould Line Dimensioning, the
indication is displayed on PS in the drawing.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so indication on SB side is also displayed on SB side.
89859 192424 Title: Printing Vitesse function error (Captured Area)
Symptoms: When printing a specific area in a drawing with vitesse function
using captured area option, the result is different from I expected.
Previous/Known workaround: No known workaround exists.
Solution: When printing a specific area in a drawing with vitesse function using
captured area only contents of that specific area are printed.
89865 192425 Title: Tools>Model>Exchange displays models in restricted area.
Symptoms: When exchanging Outfitting models, the retriction box is not taken
account for as it does for Hull elements.
Previous/Known workaround: No known workaround exists.
Solution: When exchanging outfitting models, the 3D view restriction will be
applied (as for hull models).

Diagrams:

86305 184180 Error on publishing diagram to AVEVA NET

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 269 of 517
Product Release Letter
Pipe Fabrication:

57962 98333 Title: Fabrication Check Showing Incorrect Results


Symptoms: If a branch on the spool is too short for the welding machine
incorrect results are shown on the fabrication check. Some results are related to
manual welding, despite the component in question not being manually welded.
A flange nominated as machine welded is not being shown correctly. There is no
excess allowing for some welding processes.
Known workaround: None
Solution: There were no warning being produced if no valid welding machine
was found, hence why some results were shown as being manually welded,
there is now a warning added if this is the case. The wrong positions on the
arrive.leave components were being used when calculating pipe lengths which
lead to incorrect results, this has now been rectified and the calculations are
done correctly. Added an additional check as part of the fabrication check to see
if a flanges length is valid for a manual/machine weld which was previously not
done leading to incorrect results being displayed.
60576 107309 Title: Weld Handling Deletes Spool Limits
Symptoms: Welds are not being numbered correctly they are either being
renumbered completely, or not retaining their current weld number. Spool limits
are being deleted via the weld handling form when we may not want to delete
them
Previous/Known workaround: None
Solution: If "append weld number" on the form is checked we will append weld
numbers to new welds/spool limits. If "append weld number" on the form is
unchecked we will renumber all of the welds on the element when "create all
welds for ce" is hit. This will preserve any existing spool limits, and renumber
them accordingly. When we delete welds from the weld handling form, the user is
now presented with an option to delete all welds, or to delete all welds excluding
the spool limit welds.
63535 116368 Title: Muliple Spool Text Field Blank
Symptoms:
Previous/Known workaround: None
Solution: Updated the text field with the appropriate value entered by the user.
75399 155271 Title: Pipe Spool Drawing Not Created in this Instance
Symptoms:
Previous/Known workaround: None
Solution: Calculated the cutlen.
76821 159858 Title: Fabrication Iso Spool Drawing Error
Symptoms: Elements that were not named were unable to be deleted from the
fabrication isometric form
Known workaround: Name the elements
Solution: Rather than using the "name" attribute to find the element to remove
we use the "FLNM" attribute which will provide the correct name if the element is
unnamed.
78344 164397 Title: 12.1.SP4 - Pipe Fabrication: User feed excess is set by Validate
Symptoms: NA
Previous/Known workaround: NA
Solution: Avoided the the user feed attribute being set during fabrication check
process.
80447 171417 Title: Pipe Fabrication - Part numbering is not reliable for the isometrics
Symptoms: None
Previous/Known workaround: None
Solution: Code modified to create part numbers for 'Thread Pipe End' FTUB.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 270 of 517
Product Release Letter
85129 182038 Title: Piping - Penetration ATTA should not appear in the pipe sketches
Symptoms: Penetration attas are shown dimensioned on Pipe sketches.
Previous/Known workaround: Manual drawing edits.
Solution: Attas are no longer dimesioned on pipe sketches but their
representation may still be seen.
87111 185976 Title: Pipe sketch dimensions on pipe spools with weld gaps
Symptoms: A pipe sketch with modeled welds shows dimensions to the welds
instead of overall dimensions.
Previous/Known workaround: ManualEditing
Solution: The weld components are no longer dimensioned.
87110 185993 Title: ATTA dimensioning should not appear on pipe sketches
Symptoms: Extra dimensions are seen at ATTA positions and the dimension
continuity is incorrect.
Previous/Known workaround: Manual removal in draft
Solution: These dimensions are no longer drawn.
88187 188737 Title: Plotting Icons Not Appearing On Previews
Symptoms: The Print Setup / Print buttons were invisible on the Pipe Spool
Drawings preview form
Previous/Known workaround: None
Solution: The Print Setup / Print buttons are no longer invisible if the user is
using the outfitting application.
89269 191184 Title: There is an additional SOCKET textbox on the WeldGap Options form that
was added by PD during the fixing of another issue.
Symptoms:
Previous/Known workaround: No known workaround.
Solution: Additional TextBox has been Removed which is not required in the
pfweldgapconfig.pmlfrm file.
89653 192036 Title: On the Weld Gap Config form there are two checkboxes on the Weld Gap
Options tab that are accessible even if the user does not have write access to the
database.
Symptoms:
Previous/Known workaround: No known workaround.
Solution: On the Weld Gap Config form, Weld Gap Options tab the following two
checkboxes :-
i) Create Socket Welds from Spec
ii) If component is out of spec, use same source
are greyed out and inactive the same as all the other options on the form, for any
user who does not have write access to database.
90647 194382 Title: WeldGap Config Fails in Imperial
Symptoms: If a user is using imperial units rather than metric the WeldGap
Config form is unable to store any results entered and read them back in.
Previous/Known workaround: Create all of the configs using a Metric format
and then swap over to an Imperial format. The reason we have this problem is
because some of the conversions from Imperial to Metric are slightly out (~0.1-
0.3mm) resulting in errors as the numbers don't match up. If we create the
configs in a metric format however, and then use an Imperial format after they
have been created the metric values will be converted correctly.
Solution: We store the current units and swap the units to mm during the
creation of the WeldGap configs due to the DDSE element of the config having to
be stored in a metric format. Once this element has been created we restore the
previous units and continue with the previous operation.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 271 of 517
Product Release Letter
Outfitting:

Incident Issue Description


Number Number
46381 68290 Title: Structures - Calculation error resolved in Section Multiple Attached Copy
function
Symptoms: Syntax error when the attached SCTN is connected at the start of a
SCTN.
Previous/Known workaround: Use another copy and connect method.
Solution: Resolved calculation error.
24793 68791 Title: Isodraft - Problem in Isodraft with SHU objects
Symptoms: Flange shown wrong way round.
Previous/Known workaround: None
Solution: Test for zero-length instrument.
41650 69607 Title: Isodraft - PDMS Set On Tee Issue
Symptoms: Slope of branch incorrect
Previous/Known workaround: None
Solution: For set-on tee, retain offset position for slopes.
67375 129885 Korean character is not correctly displayed in the console window.
67409 129971 Title: Draft - Configurable DXF output suppressing complex symbols
Symptoms: Complex symbols are not appearing in Configurable DXF output.
Known workaround: None
Solution: Fixed: complex symbols are no longer suppressed by Configurable
DXF output but are exported correctly.
70676 142159 Title: Isodraft - Wrong dimension on isometric using MDS Trunion TT04
Symptoms: Wrong dimension on isometric using MDS Trunion TT04.
Previous/Known workaround: None
Solution: Handle skewed trunnions correctly.
75491 157106 Title: Isodraft - Falling line ratio is incorrect in ISODRAFT
Symptoms: Falling line ratio is incorrect in ISODRAFT for imperial.
Previous/Known workaround: None
Solution: Account for imperial length when calculating fall.
70565 168475 Title: Review - Auto colour rules define in Outfitting not reflected in Review
Symptoms: Users auto colours are not loaded by Review
Previous/Known workaround: Change system auto colours
Solution: Change PML function called by Review to load users auto colours.
80178 170363 Title: Draft - VSCAN command does not return all matching elements
Symptoms: Design items without directly owned primitives are skipped
Previous/Known workaround: None
Solution: Now checks up hierarchy to find matching significant owner(s).
81880 174618 Title: Design - Tube not drawn if Repre INSU=SOLID and OBST=50%
Symptoms: Insulated tubes not drawn
Previous/Known workaround: Use different representations
Solution: Now fixed.
83167 176898 Title: Isodraft outputs the wrong font in dxf export
Symptoms: Isodraft dxf export sometimes exports text in the Standard font
rather than the user defined font.
Previous/Known workaround: None
Solution: Fixed: correct user defined font is output instead of being replaced by
the Standard font.
177252 Title: Underlines lost in dxf output for Far Eastern characters
Symptoms: Underlines lost in dxf output for Far Eastern characters such as
Chinese.
Previous/Known workaround: None
Solution: Fixed: underlines now output correctly to DXF for Far Eastern
characters.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 272 of 517
Product Release Letter
Incident Issue Description
Number Number
68410 179850 Title: Draft - Draft places two labels when there should only be one while
autotagging.
Symptoms:
Previous/Known workaround: No known workaround.
Solution: Using autotagging on branches will now results in only one label being
created per branch.
81746 181908 Title: Isodraft - Depending the cases (with bends), some overall dimensions are
missing on isometrics
Symptoms: Depending the cases (with bends), some overall dimensions are
missing on isometrics.
Previous/Known workaround: None.
Solution: Check if end of drawing or pipeline. If shop weld dimensioning is
ON and there are 2 or more components, then supply an overall dimension.
87849 187757 Title: Draft - Mixed units within a single text or label element not possible
Symptoms: All distances within a single text or label are given the same units, it
is not possible for example to have one in metres and another in mm
Previous/Known workaround: Split the intelligent text into two labels or text
elements with different units
Solution:The Intelligent Text 'Alternate Units' can now be specified as well as
the principal units, so you can have two sets of units in the same text s or label
(e.g. m and mm).
For example:
On the LAYERr:
UCODE MM DIST METRE ALT DIST

In the intelligent text use #U to switch to alternate units


'#POSX() %U(#POSX())'
88811 190002 Title: Draft - Rotated SYMBs and ellipses are distorted after export to DWG
Symptoms: Some symbols with a non zero rotation, eg those containing ellipses
or outlines with non-zero bulge factors, or with non homogeneous x and y scales,
were distorted on export to DWG.
Previous/Known workaround: None
Solution: Fixed: these symbols are now exported correctly.
88293 190184 Title: Piping - Cannot calc LVOL for TUBI from Branch Head
Symptoms: Value badly transformed.
Previous/Known workaround: No known workaround.
Solution: Now works.
89479 191577 Title: MDS - A problem where datasets copied from standard MDS supports into
MDU caused failure.
Symptoms: Error when creating an MDU support copied from an
existing standard MDS support.
Previous/Known workaround: None
Solution: Code fixed.
89512 191659 Title: Problem with CAPPING / CLIPPING in PDMS12.1.SP4.28 in OpenGL
Mode
Symptoms: Capping does not show correctly
Previous/Known workaround: None
Solution: Added support for large coordinates in GL renderer.
89458 192116 Title: Unscheduled Database Update form in Admin can give Syntax error when
you use the Filter
Symptoms: On the Unscheduled Database Update form in Admin can give
Syntax error when you enter a value in the Filter box at the bottom of the form
Previous/Known workaround: Locate and edit the following file
pmllib\global\forms\glbrmtupdatedb.pmlfrm
You need to look for '|this' and replace it with '|!this'.
Solution: Have made the workaround edit in Clearcase.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 273 of 517
Product Release Letter
Incident Issue Description
Number Number
89708 192130 Title: Deleting InterDB macro in Monitor as FREE user doesn't work
Symptoms: If you access Monitor as a FREE user and type the command
DELETE MACRO 1 on the command line, it appears the command has been
successful. You do not get an error message to tell ypu why the macro has not
been deleted, and the file on the operating system remains.
Previous/Known workaround: Delete macro in Admin.
Solution: Removed the inhibition in the code that was stopping FREE users from
deleting InterDB macros. It will now return an error if you are not allowed to
delete the macro or if it can't be found.
90397 193784 Title: 12.1.SP4.30 - new graphics is not working even on a new powerful laptop
Symptoms: Missing geometry when using arcs with very small angle
Previous/Known workaround: Force legacy OpenGL renderer by setting
environment variable AVEVA_GRAPHICS_XP_COMPATIBLE=1
Solution: Fix arc tessellation for small angles.
90289 194446 Title: Equipment - PDMS 12.1SP4.26 Design Graphics problem
Symptoms: Capping does not show correctly.
Previous/Known workaround: None
Solution: Added support for large coordinates in GL renderer.

12.1.SP4.30

Initial Design:

Incident Issue Description


Number Number
66315 125955 Title: Compartment: Doesn't consider the colour of Content Types
Symptoms: Colour code on compartments set to black on all compartmens when
released to Calc in Surface & Compartment.
Previous/Known workaround: None
Solution: Code change applied to update compartment color codes correct when
export to Calc in Surface & Compartment.
85736 183058 Title: Surface & Compartment Model Release to Dabacon issue
Symptoms: The performance of releasing Surface & Compartment data to
design is slow.
Previous/Known workaround: No known workaround.
Solution: Performance has been dramatically improved.
86001 184149 Title: Freash Water freeboard
Symptoms: According to Load Lines, 1966/1988 - International Convention on
Load Lines, 1966, as Amended by the Protocol of 1988 - Annex I - Regulations
for Determining Load Lines - Chapter III - Freeboards - Regulation 40 - Minimum
freeboards;

Fresh water freeboard


(7). The minimum freeboard in fresh water of unit density shall be obtained by
deducting from the minimum freeboard in salt water:

Δ/(40T) cm

Δ is the displacement in salt water in tonnes at the summer load waterline; and
T is the tonnes per centimetre immersion in salt water at the summer load
waterline.

Fresh water freeboard calculation do not match the above formula.


Previous/Known workaround: No known workaround.
Solution: Code change applied to correct error.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 274 of 517
Product Release Letter
Incident Issue Description
Number Number
86473, 184546, Title: Compartment names not exported from Surface & Compartment
88826 190411 Symptoms: "s" written to cxml file instead of the long name of compartment.
Previous/Known workaround: Hand edit the long names after export.
Solution: Corrected so the long name of the Compartement is exported.
88468 189378 Title: Calc Error in KGf
Symptoms: KGf did not match between equilibrium and critical report in the
loading condition report
Previous/Known workaround: None.
Solution: Error has been corrected by a code change.

Planar Hull:

Incident Issue Description


Number Number
62814 114346, Title: Bracket text disappear in detailed view after modifying
117086 Symptoms: The bracket text disappears for a bracket which has a folded flange
and bevel after recreating the panel or running the scheme.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the bracket text
does not disappear.
77684 162287 Title: NUM-term in BOU-statement
Symptoms: When a NUM term is used for COR in the boundary statement, it is
the next time the schema is activated, exchanged to the evaluated value.
Previous/Known workaround: Manually change to the NUM-term.
Solution: Correction made to allow numeric value as COR in boundary
statement.
79668 168979 Title: Unnecessary/unwanted "Activate" prompt for panels
Symptoms: In many funtions, when a planar panel is already active, the system
still requires to indicate a panel.
Previous/Known workaround: No known workaround exists.
Solution: Modified to act as Planar Hull > Model > Edit meaning no prompting for
a panel if a panel is already active.
170867 Title: Scheme cannot be updated using ‘Direct’ option
Symptoms: The Update button is disabled when trying to update a schema line
in the Statement wizard.
Previous/Known workaround: The problem is that the statement somewhere
(e.g. in a comment) a lower case letter. By purge vs slicechanging all text to
upper case letters, the button will be enabled.
Solution: Corrected so the Update button will be available in all cases.
83474 177859 Title: Impossible to modify a position number of a clip
Symptoms: When using a named clip (in a Cutout), teh fields for position number
is dimmed and cannot be changed.
Previous/Known workaround: Change position number via the scheme editor.
Solution: Fields will now be open for editing when a clip name is given.
85873 183266 Title: Unnecessary bevel values are appear in BRA statement of scheme.
Symptoms: In a bracket (syntax 1), there are bevel values (0,0,0) which has no
meaning when Automatic Bevel is used.
Previous/Known workaround: Manually remove the bevel from the statement.
Solution: The unnessesary bevel values will no longer appear in the bracket
statement.
86038 183532 Title: Interactive Jig
Symptoms: Not possible to make Pin Jigs for a Knucked Panel.
Previous/Known workaround: Make two planar panels in the same plase as the
knuckled panel and use that for jig calculation.
Solution: Function is updated to handle Knuckled Panels with one, and only
one, knuckle.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 275 of 517
Product Release Letter
Incident Issue Description
Number Number
86013 186420 Title: Bracket Toe
Symptoms: For bracket syntax 7 type KL is impossible to change toe height at
the end of arm A by giving parameter C. Giving parameter D for toe height at arm
B works fine.
Previous/Known workaround: No known workaround exists.
Solution: Modified so that C measure will affect the toe height.
87044 188175 Title: AUTO Bevel to consider GAP for MSI=TOP, BOT
Symptoms: When the GAP rule is in effect, there is no way to get the negative
bevel in case connection angle is negative.
Previous/Known workaround: Define rules for angles instead of GAP.
Solution: Corrected so the system will automatically change the bevel code sign
incase the connection angle is negative.
88325 189631 Title: Adding expression 'MNG' in hole statement by hand
Symptoms: when adding the keyword MNG to a hole that is not a managed hole,
this hole is locked and cannot be removed.
Previous/Known workaround: No known workaround exists.
Solution: Correction has been made to prohibit to give MNG for a none managed
hole and to prevent removing it.
89130 190795 Title: New panels cannot be created any more in single view mode
Symptoms: IF Hull Modeling default GEN_VIEW=SINGLE, when a new view is
added, it is not possible to create new panels via Statement Wizard. System
freezes.
Previous/Known workaround: Set GEN_VIEW to ALL.
Solution: Corrected so Statement Wizard will continue as expected when single
view is used.
89172 190900 Title: Old Views have now limits 500000 since fix 26
Symptoms: Symbolic Views created previous to SP4.Fix.26 has limit values
500000.
Previous/Known workaround: Have no practical meaning but can be confusing
and disturbing in-hous programming.
Solution: The value 500000 was previous Fix.26 supressed and is now fixed to
be supressed again.

Curved Hull:

Incident Issue Description


Number Number
78503 164954 Title: Attrib ParRef unset for CSTIFF (on SB) in CPANEL (over CL)
Symptoms: After function Curved Hull > Stiff > into profile DB, only CSTIFF on
PS will have assigned ParRef, but CSTIFF on SB will have ParRef as unset
(CPANEL is over CL).
Previous/Known workaround: No known workaround exists.
Solution: Part reference setting for CSTIFF elements are corrected.
82725 176057 Title: Wrong inclination angle of short shell profile.
Symptoms: when adding a Shell Stiffener (from the design Tree, the inclination
angle is not correct.
Previous/Known workaround: Add shell profile via "Input Model" form.
Solution: The problem has been solved so that the shell profile gets the correct
angle also when adding from the Tree view.
87742, 187479, Title: It is impossible to modify the name of seam/butt
88546, 189571, Symptoms: When renaming a Shell Seam, the system respond with error 304
88637 189660 and then aborts.
Previous/Known workaround: Export the seam into XML format. Remove the
seam using Delete function. Rename in the XML document and run the XML
import utility.
Solution: Corrected so Shell Seams can be renamed without error.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 276 of 517
Product Release Letter
Incident Issue Description
Number Number
88689 189720 Title: Curved Panel View show incorrect END2 of all cstiffs
Symptoms: Gap defined at END1 of a stiffener belonging to a Curved Panel is
shown also at END2, even if there is no gap defined. This does not depend on
how the gap is defined, explicitly or by connection code.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the gap of stiffener end 2 gets
correct also in the curved panel view.
88691 189724 Title: Cstiff split, only CON=40
Symptoms: It is not possible to control the default connection code when splitting
shell profiles.
Previous/Known workaround: Manually modify the connection on each shell
stiffener.
Solution: A new environment variable, SBH_SHSTI_DEF_CON, can be used to
set the default connection code for Shell Stiffeners. This will be used when new
shell stiffeners are created. If not defined, connection code 40 will be used.
88690 190427 Title: Shell expansion views show stiffening always on CL-side of the surface
Symptoms: Profiles created on the outside surface is shown as inside in the
ShellX draing.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that side of the profiles are also
handled in shell expansion views.
89227 191103 Title: Not possible to predefine STRIP CONTROL for shell plates.
Symptoms: Missing possibillity to redefine the default setting of Strip control.
Previous/Known workaround: Manually change for each plate.
Solution: New default keyword, PDV_STRIP_CTRL, is added. Possible values
are: "PrinciplePlane" (default), "Perpendicular" and "Distributed".
89521 191678 Title: Modification of individual cstiffs not correct!
Symptoms: When many shell Stiffeners are activated and modification is per
shell stiffener, the function stops if one of the stiffeners has no changes (ok is
presses without any changes in any fields).
Previous/Known workaround: Activate one stiffener at the time.
Solution: Corrected so the function will continue with the next stiffener in any
case.

Hull Structural Design:

Incident Issue Description


Number Number
85361 181931 Title: Dividing panels with errors
Symptoms: Various strange errors are in a model after using Structural Design -
Divide into blocks.
Previous/Known workaround: No known workaround exists.
Solution: A number of enhancements are made to the block division process
eliminating all the main problems. The enhancements are also in effect for the
split panel function.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 277 of 517
Product Release Letter
Incident Issue Description
Number Number
87002 185583 Title: FE Modeler- Surface and Planar Panel on the same location
Symptoms: If there is Surface and planar panel at the same location ,system can
not seperate each other and creates double Shell elements on top of each other.
Previous/Known workaround: No known workaround.
Solution: Note that this is only applicable in the rare case that a planar panel is
located in a surface and defined with LOC='[SURFACENAME]' and a 3D-point
(the latter is used to get the surface normal in/near that point to define the panel
plane).
When a planar panel is defined in the described way and processed by the FE
Modeller all panel components are handled as usual - except the plates - and the
thickness for the surface shell elements is fetched from the panel plates. This will
avoid duplicated elements.

Hull Production:

Incident Issue Description


Number Number
84420 179675 Title: Add Hull Curve to jig drawing.
Symptoms: Not possible to add arbitrary Hull Curve to the Jig sketch.
Previous/Known workaround: No known workaround exist.
Solution: The possibility to select an abritary additional hull curve and get it
drawn with name into the JIG sketch has been added both for batch and
interactive JIG pillars.
87735 187495 Title: Painting Area Calculation are not the same in csv output files
Symptoms: The sum of Area in the two output files are not the same.
Previous/Known workaround: The sum in the detailed list is the correct one.
Solution: Corrected so the sum of area is the same in both lists.
88109 188496 Title: The marking of PS-side only is generated in SB-side Plate.
Symptoms: Port side only abbutting profiles are marked on a SB only plate.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so only valid panel marking is available on SB panel.
87237 189128 Title: Template Drawing Dummy View
Symptoms: In the receipt drawing of Bending Templates, there are created
empty views which has no purpose.
Previous/Known workaround: No known workaround.
Solution: The empty views are no longer created.
89321 191435 Title: Bending template direction mark
Symptoms: Direction mark (small triangle) is wrong drawn in bending template
sketch.
Previous/Known workaround: No known workaround exists.
Solution: The template direction was handled in an incorrect way thats why the
number was upside down. This is now handled.

Hull Nesting:

Incident Issue Description


Number Number
79528 169324 Title: Rest Plate cannot be created on the same area of previously deleted old
Rest Plate
Symptoms: Not possible to create a rest plate from a hole if this has previously
been created and deleted.
Previous/Known workaround: No known workaround exists.
Solution: The code has been corrected so it will be possible to create the rest
plate.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 278 of 517
Product Release Letter
Incident Issue Description
Number Number
86728 185118 Title: Hull profile nesting problem
Symptoms: Nesting of profiles (I-bars) is not placed on the same raw profile.
Previous/Known workaround: No known workaround exists.
Solution: Profile nesting corrected for I-bars so the full length of the raw material
is used.
88258 189046 Title: AUTO_POSNO_POSITION is not working
Symptoms: The system is not consider any value of AUTO_POSNO_POSITION.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so AUTO_POSNO_POSITION is handling the parameters
and the position number is placed accordingly.
88462 189685 Title: PLCM Crash
Symptoms: PLCM application crashes, when you press Cancel button in New
nesting (NestJob New) dialog box.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the application do not abort when Cancel is pressed.
89035 190578 Title: Open nesting with missing parts crashes the application
Symptoms: See title.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so missing parts will be handled and Nest will be opened.

Hull Weld Planning:

Incident Issue Description


Number Number
78194 163855 Title: Weld is created in the opposite side
Symptoms: Calculated weld was created on the wrong side of a Collar Plate.
Previous/Known workaround: No known workaround available.
Solution: The weld is created on the correct side of the Collar Plate.

Marine Drafting:

Incident Issue Description


Number Number
60447 106802 Title: Labels are not working for cpanel, cplate, etc.
Symptoms: As there are missing ppoints for Shell Plates, it is not possible to add
lables for the plates.
Previous/Known workaround: None
Solution: Mould points have been added for corners and a point on the shell
plate.
The corner points are in the 100 - 149 range and the point on the plate has index
150. The PDIR attribute will return the same vector for all points.
61857, 111516, Title: When trying to store a drawing in a linked PADD, its not stored, but no error
72185 146904 message
Symptoms: When opening any drawing and trying to store it in a linked non
writable db, a possible post trigger is running, no error message, but the drawing
is not stored.
Previous/Known workaround: No known workaround exists.
Solution: An error message is now displayed when failing to store a drawing in a
linked PADD.
67028 128347 Title: Marine Drafting Open claimed drawing information warning
Symptoms: There are no message when trying to open a drawing that is already
claimed by another user.
Previous/Known workaround: No known workaround exists.
Solution: An error message will be displayed when the drawing is already
claimed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 279 of 517
Product Release Letter
Incident Issue Description
Number Number
72989 149241 Title: The keyword SEARCH_ALL_DEPTS for marine draft default is invalid
Symptoms: The keyword SEARCH_ALL_DEPTS can have the value yes or no
but here is no differance in search.
Previous/Known workaround: No known workaround.
Solution: The keyword "SEARCH_ALL_DEPTS" in Marine Drafting has now
been removed. It has no meaning in 12.1.SP4.
74804 153237 Title: Marine Drafting Open claimed drawing information warning
Symptoms: There are no message when trying to open a drawing that is already
claimed by another user.
Previous/Known workaround: No known workaround exists.
Solution: An error message will be displayed when the drawing is already
claimed.
74941 153765 Title: Marine Drafting Open claimed drawing information warning
Symptoms: There are no message when trying to open a drawing that is already
claimed by another user.
Previous/Known workaround: No known workaround exists.
Solution: An error message will be displayed when the drawing is already
claimed.
75654 156288 Title: Model Info not fetch the information from Assembly Model
Symptoms: Using Model Info on an Assembly View does not give any result. It is
no problem on an ordinary Model View.
Previous/Known workaround: No known workaround exists.
Solution: Model Info is now fetched from Assambly Model. An Update Design is
needed on already created views.
173770 Title: Dimensioning Radius will show a maximum of 2 decimal values
Symptoms: Changing the number of decimals to more than two decimals for the
Radius measure does not work.
Previous/Known workaround: No known workaround exists.
Solution: When creating radius or diameter dimensioning, the precision will not
be restricted to two decimals anymore.
82809 176159 Title: DWGPurge() does not do the same as the interactive function
Symptoms: It does not do the same as the interactive Function "Tools, Inspect
Drawing, Purge".
Previous/Known workaround: No known workaround exists.
Solution: To get same behavior in DwgPurge compared to interactive function
Tools/Inspect Drawing/Purge, one requirement is that customer have the same
settings for MODEL_SUBVIEW_PURGE and MODEL_VIEW_PURGE also when
invoking DwgPurge. This is customers responsibility to check this.

Moreover, to be able to have same behavior regarding the handling of totally


sliced-away model subviews, an optional parameter "PreserveSlice" has been
added to DwgPurge (and DwgPurgePML):

Should model subviews, totally sliced-away be preserved ?

= 0 No
= 1 Yes (default value)
The value of "PreserveSlice" should correspond to what was ordered during
interactive transform (here the user is explicitly asked how to treat sliced-away
model subviews)
83435 177668 Title: DXF export doesn't export some subpictures
Symptoms: Some subpictures are missing in the export.
Previous/Known workaround: Try defining the variable
DXFOUT_EXPLODE_DIM.
Solution: Corrected so the missing subpictures are exported.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 280 of 517
Product Release Letter
Incident Issue Description
Number Number
84050 178849 Title: Enhancement to show Evaluated Text at first in Modify dimension.
Symptoms: When you modify to Dimension Text, evaluated text showed first.
Previous/Known workaround: Original text is showed first. Select “Option” to
see evaluated text.
Solution: The issue is solved by remembering from where the predefined text
(original or evaluation) was fetched, troughout the session. This means that:
1. The first time the function "Edit dimension text" is used, the predefined value is
initially fetched from original text
2. The following times the function is used, the predefined value is initially fetched
from last used source.
84912, 180974, Title: Problem not to verify the models to newly add the symbolic view at the
86031 183504 attached drawing.
Symptoms: View ID's sometimes get's corrupt and the system does not
recognize the view as a Model View.
Previous/Known workaround: No known workaround exists.
Solution: Check and repair if View ID's will now be done automatically whenever
a drawing is opened (File/Open, SHEET/Open, MarApi DwgOpen, Import SDB).
86419 185061 Title: Defect of Note
Symptoms: Aligned multi line texts on note return to default after move the
note.
Previous/Known workaround: Manually rearrange the note after it has been
moved.
Solution: Position of note text is now kept after move operation.
82038 185281 Title: Modify Dimension Presentation Hot Key
Symptoms: There are four alternative in "Text and Arrow Layout" when
modifying a dimention. Request is to be able to use keystroke 1-4 instead of
mouse click to select which style to use.
Previous/Known workaround: Only mouse indication is available.
Solution: It is now possible to use keyboard keys 1-4 to select the wanted layout
in Modify/Dimension/Presentation dialog as well as mouse click.
87009 185609 Title: After recreate Shell expansion view, Part seams are disappear.
Symptoms: After recreating a shell expansion view it could happen that some
seams disappeared.
Previous/Known workaround: No known workaround.
Solution: The problem has been solved so that some seams are not
disappearing after recreating a Shell expansion view.
87338 186289 Title: SVIEW_LT_COL - STI_ABUT_TS and STI-ABUT_OS are not working
Symptoms: The statements for LT object STI_ABUT_TS and STI-ABUT_OS are
not working.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so Line type for abutting stiffeners is handled via the LT
object.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 281 of 517
Product Release Letter
Incident Issue Description
Number Number
186324 Title: Copy Drawing - give explicit new name to drawing copy
Symptoms: Improvement to existing interactive/batch Copy Drawing function
Previous/Known workaround: No known workaround.
Solution: It is now possible to give an explicit drawing name when copying a
drawing in interactive mode, in batch mode and using a MarAPI method. All of
these three options only works at SHEE or DRWG levels.

The "Copy Drawing" dialogue has been updated with a new field to give the
explicit name. If given, the prefix/suffix fields for the drawing are disabled.

The batch function has a new keyword, "newdwgname" to give a drawing an


explicit name. This is optional to the user.

A new MarAPI method has been implemented, "dwgcopy", which takes three
arguments; name of source drawing, name of target registry and explicit name of
new drawing. If an empty string is input as new explicit name, then autonaming is
used (old name with prefix or suffix).
87412 186529 Title: Penetrations under SCTNs and STWALLs cannot be picked or have their
own representation
Symptoms: Penetrations under SCTNs and STWALLs, unlike FLOORs and
PANEls, always get their representation from their owner elements and cannot be
given their own representation rules, nor can they be picked.
Previous/Known workaround: Labels can be placed manually against
penetrations eg using the syntax "ON <penetration-design-element>
Solution: Penetrations under SCTNs and STWALLs now behave like those
under FLOORs and PANEls, so any representation rule that affects the
corresponding design element will be applied. The penetration will also be
pickable, but only where it corresponds to a design or catalog entity for which
ppoints are defined.
Note that representation rules do not distinguish between negatives and
positives, so if an element under the SCTN or STWALL has both, the penetration
and the standard geometry will pick up the same representation.
87830 187661 Title: department without a name created in PADD database, where it should
give the warning
Symptoms: When there is no department in PADD database, system creates a
nameless department and registry
Previous/Known workaround: None
Solution: The problem is fixed:
1. The system behaves the same way if you remove the drawing type in the "New
Drawing" dialog.
2. You will get a message "Failed to persist the new drawing in the PADD
database" instead of having a new drawing in an unnamed dept/regi.
88111 188498 Title: Marine drafting Insert Model out of slice scope in the sketch
Symptoms: when adding outfitting models to a Marine Drafting View, the models
are not clipped.
Previous/Known workaround: No known workaround exists.
Solution: The problem is fixed, outfitting models should now be clipped also
when adding models to an existing view.
88704 189854 Title: Unable to regroup a subpicture level 3 while using the Polygon NOCUT
option
Symptoms: While attempting to use the Tools > Subpicture > Regroup, and
making use of option 6 (set to NOCUT) followed by option 4 (Polygon), the
system reports a FATAL ERROR and crashes after drawing the selection box.
Trying the same command but using option 3 (Geometry), works successfully.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so system will not abort.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 282 of 517
Product Release Letter
Design Reuse:

Incident Issue Description


Number Number
69484 138538 Title: After copying, the definition of Assembly view on Symbolic view is not taken
over.
Symptoms: When you export the drawing file who has one or some Assembly
views to import to other project, these view has been changed from Assembly
View to Design View in the imported project.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so Design Reuse makes sure that the assembly info stored
in drawing view is updated as according to target project. The assembly name
(ref)used as source in HSV creation in source project should be changed as
according to target project at import. This presumes a proper rename script for
assemblies as required by Design Reuse.

Diagrams:

Incident Issue Description


Number Number
66639 127107 Title: Duplicate name error
Symptoms: Savework errors didn't contain proper, meaningful error text.
Previous/Known workaround: No known workaround.
Solution: Savework error message has been improved to contain the actual error
text.
71602 157774 Title: Mirror function is not usable
Symptoms: Mirror (Flip) function disconnects shapes.
Previous/Known workaround: No known workaround.-
Solution: Selection Flip command will no longer disconnect shapes. Results still
may look strange if lines were adjusted manually, but this could be fixed by using
Reset Connector tool.
76522 158971 Title: SCTUBING is not detected inside SCAREA unless a fitting at edge of area
is moved from boundary.
Symptoms: SCTUBING is not detected inside SCAREA unless a fitting at edge
of area is moved from boundary.
Previous/Known workaround: Move shape.
Solution: Area shapes members are now properly refreshed when defining and
deleting an inline shape.
87726 187451 Title: DELETE Option in Search Result of DIAGRAMS12.1.SP4 is not longer
available
Symptoms: DELETE Option in Search Result of DIAGRAMS12.1.SP4 is not
longer available.
Previous/Known workaround: No workaround, maybe create own PML macro
to find and delete required elements.
Solution: Delete command was restored.
87969 188028 Title: Changed Value from Tab DEFAULT SYSTEM within the Session
Defaults are not considered for copies
Symptoms: Default System from "Default System Tab in Session Defaults
window" is not being set when shape is copied.
Previous/Known workaround: Set SCSYSF attribute in Default Attributes tab
instead of Default System tab.
Solution: The fix aligned the Default System Tab (in Session Defaults window)
with the rest of default attributes, so it will be now applied correctly for the copied
Shape if "Use Session Defaults" setting is set to true in Intelligent Copy Settings.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 283 of 517
Product Release Letter
Engineering:

Incident Issue Description


Number Number
66607 126877 Title: Attributes form truncates text
Symptoms: Attribute form truncates text on re-sizing column if column width is
not enough to accommodate value.
Previous/Known workaround: No known workaround.
Solution: On resizing column attribute value will be shown followed by ellipsis if
text is too long.
70934 142645 Title: XLSX file cannot be exported correctly from "Run Report"
Symptoms: XLSX file cannot be exported correctly from "Run Report”.
Previous/Known workaround: No known workaround.
Solution: Reports are exported to XLSX file with the same values as seen from
Run Report.
83329 177372 Title: Compare/Update: Owner Expression in CU Configuration is not working
Symptoms: Update is not picking owner specified in config owner expression
Previous/Known workaround: No known workaround.
Solution: Owner specified in config will be given preference.

Mechanical Equipment Interface (MEI):

Incident Issue Description


Number Number
66346 126199 Title: AUTOTAGG_Taggs for GENPRI
Symptoms: not possible to use Annotate-->Label on imported Equipments.
Previous/Known workaround: No known workaround exists.
Solution: The Mechanical Equipment Interface import has been changed in that
way that it transforms the GENPRIs so that the POS attribute refers to the
minimum point of the bounding box of the GENPRI.

Pipe Fabrication:

59048 102470 Title: Pipe Fabrication: Changing of spool type leaves pipe validated
Symptoms: NA
Previous/Known workaround: NA
Solution: Introduced a condition to check Modified Spools count greater than
zero or not. If the count is greater than zero invalidating all pipe pieces of that
particular spool.
73900 151561 Title: If the attribute PSTYP of the PSPOOL has one value settled by user, this
value should remain till th
Symptoms: NA
Previous/Known workaround: No known workaround.
Solution: when spool type has been changed by the user and when the system
changes it to another type an information message box is displayed.
81025 172558 Title: [PipeFabrication]Pipe Spool is splitting between branches even if there's
no break fitting
Symptoms: NA
Previous/Known workaround: No known workaround.
Solution: Supplemented logic to check SHOP properly. If the order for SHOP is
not same as MAS, the program works incorrectly.
83236 177081 Title: Abnormal Material Lists in Those Pipe Spool Drawing Including Set-on Tee
Elements
Symptoms: N/A
Previous/Known workaround: No known workaround.
Solution: New method introduced in code to set part number '0' to set on tee's,
that solved the issue.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 284 of 517
Product Release Letter
86420 184406 Title : Cannot add or validate spool if SPKBRK attribute of ATTA is false
Symptoms :Cannot validate with an error '(2,201) Element ileave tube of
ATTACHMENT 1 of BRANCH 1 of PIPE 1 of ZONE /TEST-DSME does not have
attribute SHOP'.
Previous/Known workaround: No known workaround.
Solution: Code now checks that the element next to the ATTA is not a TUBE
element, if it isn't we check the SHOP attribute of the next component, if it is we
use the default SHOP value of true.

Outfitting:

40213 65506 Title: Piping - New 3D component creation function added


Symptoms: The user is unable to pick a component position outside the
constraints of the current centreline.
Known workaround: No known workaround.
Solution: Now the "place in Line" button recognizes the type of pick and if it is
not in TUBE, it uses the picked position to locate the new item along the current
constrained centreline.
39762 67063 Title: Cable - Incorrect position of mark ce of cable
Symptoms: The position of mark ce of cable is incorrect.
Previous/Known workaround: No known workaround.
Solution: Defect is now fixed and now making cable marks start and end cable.
59915 104889 Title: HVAC Stiffeners (Longitudinal) and flipping of same
Symptoms: Customer wants to be able to have stiffeners along length if HVAC
items
Previous/Known workaround: No standard solution except User defined
components.
Solution: PML additions but also rely on a Model Change in
MASTER/HVACCATA (delivery required from AVEVA to maintain reference
numbers for future) 12.1.sp5 and E3D2.1 are the next scheduled Project
deliveries.
59297 113073 Title: Piping - The user would like to restrict NSBC Boss connections to
components
Symptoms: N/A
Previous/Known workaround: N/A
Solution: The toggle on the defaults form has been changed to read 'Boss
connections not allowed in Tube' and it does just that. Before it stopped any type
of NSBC connection in tube but now it restricts the selection boss type couplings.
72159 146782 Title: HVAC - Wrong Default value in radius following a reducing element
Symptoms: Radius based on Arrive of prev.
Previous/Known workaround: Type correct value to input field.
Solution: Based default on Leave size to give correct value.
76216 158132 Title: Equipment - Penetration marker not created at the correct level in Design
Template Equipment hierarchy
Symptoms: The system tries to create the penetration marker in an equipment
template.
Previous/Known workaround: No known workaround.
Solution: The system has been changed to ensure that the penetration marker
is created at SUBE or EQUI level.
78365 165848 Title: Isodraft - Ignore Split ATTAs
Symptoms: Split ATTAs always split isometric.
Previous/Known workaround: No known workaround.
Solution: New SPLIT clause NOATTAS.
80115 170233 Title: Equipment - Sub-equipment design template PTYP incorrect
Symptoms: PTYP of sub-equipment data element set to SBRE instead of SUBE
Previous/Known workaround: Reset value using Attributes form.
Solution: PTYP for this type of data element now set to SUBE.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 285 of 517
Product Release Letter
80769 172064 Title: Isodraft - Disable NSBC Detail Plot production
Symptoms: Cannot disable production.
Previous/Known workaround: No known workaround.
Solution: New option provided on Detail Plots Option form.
80843 172217 Title: Piping - OSType attribute returns incorrect value on first tubi in branch
Symptoms: Incorrect OSType returned for first TUBI in branch.
Previous/Known workaround: No known workaround.
Solution: Returns OSType BRAN.
74695 174450 Title: Structures - FIXING added to CE mirror list of element types
Symptoms: FIXINGs not copied by CE mirror function.
Previous/Known workaround: Use graphical selection, not CE.
Solution: FIXING added to CE mirror list of element types.
81832 176121 Title: Admin - SCOPE of ALL FOR BLOCK not working as expected
Symptoms: When trying to create an ACR for a basic Hull designer, who has a
SCOPE of all elements for a BLOCK and below. The ROLE is provding access
for ALL elements and the SCOPE is defined as ALL FOR BLOCK. However, the
result is access to all elements below the BLOCK but not the BLOCK itself.
Previous/Known workaround: As a work-around, you can adjust my SCOPE to
ALL, and create a ROLE-PEROP for BLOCK HIERAR but this may cause issues
in the future.
Solution: Code has been changed to include the element when creating the
secondary hierarchy. This was the cause of the problem. The BLOCK definition
is defined with the SECOLL set which means to just use the secondary
hierarchy.
79384 177451 Title: HVAC - Add Flip oin this releaseption to HVAC Stiffener forms
Symptoms: Previously had to Flip on command line
Previous/Known workaround: Flip on command line
Solution: Option 'Flip & Connect' added to form ...but also rely on a Model
Change in MASTER/HVACCATA (delivery required from AVEVA to maintain
reference numbers for future) 12.1.sp5 and E3D2.1 are the next scheduled
Project deliveries.
83880 178521 Title: Report Designer, PMLADDIN "XLSX output" format is lost.
Symptoms: N/A
Previous/Known workaround: No known workaround.
Solution: Able to export report to XLS format through pml macro by setting
export Text mode either 'Text' or Value'.
84321 179495 Title: Piping - Include acrossdb does not update detref on spco if SDTE element
has been transfered.
Symptoms: DETREF set to unknown ref.
Previous/Known workaround: Needed manual correction.
Solution: Now fixed.
84746 180600 Title: Admin - PFIT with CMPREF gives bad weight for panels
Symptoms: Weight of panel double the true value.
Previous/Known workaround: No known workaround.
Solution: Fixed.
84658 180650 Title: HVAC - HSVLD not working the same as PSVLD
Symptoms: Missing pseudo attribute.
Previous/Known workaround: Use UDAS?
Solution: New pseudo logical attribute HSVLD added which returns true if a
hVAC spool is valid.
86172 184347 Title: Reporting - Error while extracting the report :Parameters in Report
designer
Symptoms:
Previous/Known workaround: No known workaround.
Solution: Parameters shows appropriate values in both preview and on run
report.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 286 of 517
Product Release Letter
86885 185343 Title: Isodraft - FTUB weight incorrect for Skey TUBE
Symptoms: Component weight is treated as a unit weight and multiplied by
fitting length.
Previous/Known workaround: No known workaround.
Solution: Divide BRWEIG by FITLEN for FTUB with Skey TUBE.
87085 185733 Title: Problem not to pick the compents when set REPRESENTATION
INSULATION into ON
Symptoms: translucent insulation for piping components cannot be picked.
Previous/Known workaround: Use solid insulation.
Solution: Now fixed.
87090 185738 Title: Design - Problem for some elements(CTOR / RTOR / EXTR / SNOU) not
to apply to translucency
Symptoms: Drawn solid
Previous/Known workaround: None
Solution: Fixed.
87147 185849 Title: Structures - Problem not to display structural steel objstructions when
setting into translucency for obstruction
Symptoms: Obstructions drawn solid
Previous/Known workaround: None
Solution: Fixed.
87412 186529 Title: Draft - Penetrations under SCTNs and STWALLs cannot be picked or have
their own representation
Symptoms: Penetrations under SCTNs and STWALLs, unlike FLOORs and
PANEls, always get their representation from their owner elements and cannot
be given their own representation rules, nor can they be picked.
Previous/Known workaround: Labels can be placed manually against
penetrations eg using the syntax "ON <penetration-design-element>
Solution: Penetrations under SCTNs and STWALLs now behave like those
under FLOORs and PANEls, so any representation rule that affects the
corresponding design element will be applied. The penetration will also be
pickable, but only where it corresponds to a design or catalog entity for which
ppoints are defined.
Note that representation rules do not distinguish between negatives and
positives, so if an element under the SCTN or STWALL has both, the penetration
and the standard geometry will pick up the same representation.
87532 186818 Title: Design - FT06 ancillary orientation error
Symptoms: Framework ancillaries do not orientate properly with the direction
input in the direction form.
Previous/Known workaround: Manual rotation of the ancillary in the mdsFT06
form.
Solution: Fixed.
87559 186883 Title: Spooler - NSBD detail plots absent from Spool Drawing isometric
Symptoms: No NSBC detail plots.
Previous/Known workaround: None
Solution: Create NSBC detail plots for Spool Drawings.
87377 187003 Title: HVAC - Penetrations on the arrive side of curved HVAC components
Symptoms: Penetration incorrectly positioned and fails validation.
Previous/Known workaround: None
Solution: Improved calculation of arrive side penetrations with curved HVAC
components.
87692 187256 Title: MDS reports missing text in description
Symptoms: Hyphenated description text would be trimmed so that only the text
after the hyphen is displayed.
Previous/Known workaround: No known workaround.
Solution: Fix to reporting software.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 287 of 517
Product Release Letter
88485 189396 Title: Admin - Export format is in xlsx but import is in xls
Symptoms: You can only import files with an extension of XLS
Previous/Known workaround: None
Solution: Changed file filter to Export as XLSX (as this is the format the files are
exported as) and import nows has XLSX as well as XLS.
87817 189878 Title: Attribute Usrwcogravity do not take into account local axis of Equipment
Symptoms: Wrong COG.
Previous/Known workaround: Use Design Point with COFG purpose
Solution: Now corrected.
89755 192328 Title: (2,754) Argument 1 to GT is unset found trying to create a boss connection
Symptoms: None standard Branch connections fail with an array error
Previous/Known workaround: No known workaround.
Solution: This error is resolved by anticipating the possible error.

12.1.SP4.29

Planar Hull:

Incident Issue Description


Number Number
86731 185075 Title: Hull seam color problem
Symptoms: when modifying a Planar Hull Seam with help of the Statement
wizard, the named bevel is removed from the seam. Also the bevel colour in the
symbolic view is reset to standard colour.
Previous/Known workaround: Manually add the bevel if it was removed and
recreate the symbolic view when panel is ready.
Solution: Problem with missing information in the Wizard for bevel in seams are
corrected. Also the colour issue is handled.
87316 186252 Title: Gap length of end connection is not correct for the slant flat bar
Symptoms: In case a flat bar (pofile type 10) is inclined and connected to the
outer panel boundary, the material is not taken in concideration for the connection
gap.
Previous/Known workaround: The wrong Gap handling for flat bars was
introduced in AVEVA Marine 12.1.4 fix.26.
Solution: Fixed so the correct gap will be set for inclinied flat bars connecting to
the boundary limit.
87765 187534 Title: Gap length of end connection is not correct for the slant flat bar
Symptoms: In case a flat bar (pofile type 10) is inclined and connected to the
outer panel boundary, the material is not taken in concideration for the connection
gap.
Previous/Known workaround: The wrong Gap handling for flat bars was
introduced in AVEVA Marine 12.1.4 fix.26.
Solution: Fixed so the correct gap will be set for inclinied flat bars connecting to
the boundary limit.

Curved Hull:

Incident Issue Description


Number Number
87746 187507 Title: ShellX after recreation of cplates not correct anymore.
Symptoms: Doing recreate of a shell plate that is in a Shell Expansion View, is
removed from the view.
Previous/Known workaround: Make a new Shell Expansion View
Solution: Corrected so the plate will not be removed from the view. Existing
ShellX views must be recreated.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 288 of 517
Product Release Letter
Hull Structural Design:

Incident Issue Description


Number Number
78138 163793 Title: RSO XML import issues
Symptoms: Limits defined with a surface did not get any direction stored in the
XML-output and the XML file ccan not be imported correctly.
Previous/Known workaround: No known workaround exist.
Solution: Corrected so the output XML files can be imported again.

Hull Production:

Incident Issue Description


Number Number
68983, 137137, Title: AutoBevel of stiff is strange in some parts.
69787§ 139460 Symptoms: The bevel for the flange in a L or T bar sometimes gets strange
value when using automatic bevel handling.
Previous/Known workaround: Rerun the stiffener statement, and only that
statement. Save the panel.
Solution: The problem is corrected and the right bevel code will be fetched for
the flange bevel.
86618, 184915, Title: Bending template positions drawn wrong in to output sketch
87786 187584 Symptoms: Markings for template position merge together on sketch
Previous/Known workaround: No known workaround exist.
Solution: The markings for template position was all in the same position
because of incorrect calculation of excess. It's now been fixed so markings are
correct.
87074 185726 Title: Macro-clips have zero weight.
Symptoms: When using Macro Clips and not defining any quality to the clip, the
weight is zero. The quality should be taken from the plate it is attached to.
Previous/Known workaround: Add the same quality in the schema as for the
plate.
Solution: Corrected so quality will be fetched from the plate when not defined in
the CUT statement or in the macro.
87761 187541 Title: Bending information of welded flange has a problem
Symptoms: Bending information of welded flange which panel location is SP, is
not correct.
Location of bending information has been reversed inside and out.
Previous/Known workaround: No known workaround exists.
Solution: Bending curve information for starboard flanges on panels over centre-
line corrected.

Hull Nesting:

Incident Issue Description


Number Number
87568 186819 Title: Nesting Sketch - text with marking line name is not shown
Symptoms: Having a markingline defined with the MAR statement in a Planar
Panel, will not be presented with it's name in the Nesting burning Sketch.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the texts for both the Marking Plane and the specific
markingline resulting from the MAR statement is displayed with their names in the
burning sketch.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 289 of 517
Product Release Letter
Marine Drafting:

Incident Issue Description


Number Number
84438 179728 Title: DXF Export Problem.
Symptoms: Export DXF(Version R12) in Aveva Marine, the DXF files don't have
any text information
Previous/Known workaround: No known workaround exists.
Solution: Added support for texts in DXF version AC1009 (AutoCAD 12).
84476 179865 Title: Enhancement to redefine the limits of a detail top side view of a stiffener
Symptoms: Stiffener Top view is not possible to modify the limits.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the stiffener detail top view limits
can be modified and also that automatic selection can be applied when
the view is picked.
86436 184423 Title: 'Replace existing view' moves pipe model view in a Symboloc view.
Symptoms: After adding Pipes to a Hull Symbolic View and then replace the
View with a new view, the pipes are moved outside the view.
Previous/Known workaround: No known workaround exists.
Solution: The issue regarding "replace existing view" has now been fixed.
87868 187789 Title: Model info doen not work on intersecting stiffeners on knuckled panels
Symptoms: It is nor possible to indicate a crossection of a stiffener that belongs
to a knuckled panel.
Previous/Known workaround: No known workaround exists.
Solution: The stiffeners in section views of a knuckled panel does not have the
correct ID. When this fix is included, the symbolic views must be recreated in
order to get the view ID's correct.

Schematic 3D Integrator:

Inciden Issue Description


t Number
Number
86239 184999 Title: 12.1.SP4: Tests with 3D-Integrator at FSG
Symptoms: Newly built pipes not comparing cleanly.
Previous/Known workaround: When routed with more detail they compare
better.
Solution: Fixed some specific cases where simple pipe connected with minimal
content.

Pipe Fabrication:

63533 116365 Title: Modify Spool Form - 3D View Obscurred


Symptoms:
Previous/Known workaround: None
Solution: When showing Loose Components, if the Component Attributes form
is opened the FLANGE label hides the LOOSE label.
pfModifySpool and pfComponentAttributes files are modifed to resolve it.
71489 144751 Title: Joint Prefix and Number for Gasket on Pipe Fabrication Check
Symptoms: Joint prefix and number for gasket will not be assigned on Pipe
Fabrication Check
Known workaround: It is possible to assign this information manually.
Solution: Program modified to use Joint Prefix and Joint Number for gasket.
(Please refer attached document).

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 290 of 517
Product Release Letter
72071 146529 Title: Stype Error on Weld Handling
Symptoms: If there is no proper stype, the program will be stopped.
Previous/Known workaround: No known workaround.
Solution: The program modified to have below message if there is proper Stype
for creating weld(s). "The Stype specified on the Weld Gap Config form does not
exist in the current Pipe specification".
74329 154644 Title: Welds should be povided with proper naming and numbering when created
using component creation form
Symptoms:
Previous/Known workaround: when user added welds from weldhandling form,
already existing welds created using componentcreation form will having proper
naming and numbering.
Solution: Welds are given naming and proper serial number while created using
component creation form.
75857 157504 Title: WELD HANDLING FOR DIFFERENT SPEC
Symptoms: While running the Weld Handling for Creating Weld at various
location if the Pipe Consist of different Spec Component the Weld is Created with
the Spec of Pipe and not Component which results out as Spec Break at every
interval.
Previous/Known workaround: No known workaround.
Solution: Based on the status of of CheckBox labelled 'If component is Out of
Spec, use the same source' in Weld Gap Config form, the spec has been taken
from the Component to assign weld.

Outfitting:

Incident Issue Description


Number Number
46683 70196 Title: Piping - Ability to control the length of tube between invalid piping
connections.
Symptoms: When a piping component cannot be connected to a previous
component, a minimum length of tube must exist between the components. It
was not possible to control this length of tube by bore size.
An error message was displayed which always read the same length of tube
which was confusing to the user.
Previous/Known workaround: None
Solution: It is now possible to either control the length of tube inserted
between invalid connections by modifying either the default tube length or the
bore ranges in the data consistency checker.The correct distance is now
displayed in the error message when an invalid connection occurs. For more
information refer to section Enhancements above.
58812 101633 Title: Piping - Ability to Merge pipes that are in different DB's
Symptoms: Merging pipes across dbs is not supported on the pipe splitting
form.
Previous/Known workaround: Use syntax to include across dbs.
Solution: This is now fixed as part of the pipe splitting application. For more
information refer to section Enhancements above.
59295 103493 Title: Piping - Non Standard Branch connections need to be restricted to
certain sizes and Pipe classifications
Symptoms: Currently Non standard connections can be used at will on any
pipe at all available bores.
Previous/Known workaround: N/A
Solution: We have now introduced a piping settings form in Design which is
able to specify how Non-Standard branch connections can be used.
Additionally a new Tapping table type has been introduced in the catalogue
database so that bore sizes can be limited. Pipe specs may also be linked to a
tapping table via its Tapreference attribute. For more information refer to
section Enhancements above.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 291 of 517
Product Release Letter
Incident Issue Description
Number Number
59298 103497 Title: Piping - After creating and positioning a new branch in NSBC it is not
possible to change the branch bore.
Symptoms: N/A
Previous/Known workaround: Delete the branch and start again.
Solution: It is now possible to change the bore after initial creation and
positioning so long as the branch has no components. The bore gadget has
now been moved to a more suitable position so that the user is more aware of
what bore he is using. For more information refer to section Enhancements
above.
59294 103860 Title: Piping - Sometimes it was not possible to adjust the position of a Non
Standard Branch Connection on an ELBO.
Symptoms: Variable !INTERSECTION does not exist message.
Previous/Known workaround: None
Solution: There was a problem with some elbows and bends not giving the
correct centre line arc in the underlying geometry calculations. There was test
to find the branch intersection with the bend centre line and it was supposed to
return a position from an array of two values. In some cases neither position
intersected the arc so no value was returned. This is now fixed. For more
information refer to section Enhancements above.
69936 140048 Title: When ISOTYPE is SPOOL and pipe has PTAPS, these are losing their
representation.
Symptoms: When ISOTYPE is SPOOL and pipe has PTAPS, these are
losing their representation.
Previous/Known workaround: None
Solution: When handling spools, take account of Non-standard Branch
Connections.
68593 141603 Title: Toolbar Docking
Symptoms: Floating toolbar position not restored between application
switches
Previous/Known workaround: Toolbars must be repositioned by hand after
application switch.
Solution: Restore floating toolbar positions.
73586 150668 Title: Isodraft - On Imperial project, SKEW's value has no ['] or ["]
Symptoms: On Imperial project, SKEW's value has no ['] or ["]
Previous/Known workaround: None
Solution: If no fractions of inches, old code neglected to add "
84413 180267 Title: Problem moving a selected pipe part with Model Editor
Symptoms: Piping element moves to the wrong location
Previous/Known workaround: If the Pipe Editor is stopped and then
restarted then the element can be moved correctly.
Solution: The piping element now moves the right way without having to
restart the Pipe Editor.
84801 183231 Title: EDG(Event Driven Graphics) function Error
Symptoms: when using EDG(Event Driven Graphics) function on floated 3D
view, It has raised un-expected fatal error.
Previous/Known workaround: No known workaround.
Solution: Fixed SGL to track Current_View. It was NULL following a prior
window deletion and that caused the crash. Also added code to protect
against windows which have been deleted outside of SGL and the reference in
SGL is not deleted.
86645 184866 Title: Admin - Crash caused by long session comments
Symptoms: Application crashes during Admin Backtrack or querying session
history
Previous/Known workaround: Ensure that session comments are less than
160 characters long
Solution: Have changed code so that it will accept the longer comments for
CSESS, DSESS, RSESS and USESS.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 292 of 517
Product Release Letter
Incident Issue Description
Number Number
86753 185051 Title: Fatal error when using EDG after deleting a view in drawing
Symptoms: Clicking in empty space in 3D view after deleting a view in
drawing while using EDG results in fatal error
Previous/Known workaround: Avoid clicking in empty space.
Solution: Fixed graphical interaction application code.
86878 185289 Title: Behind model has been highlighted if ModelEditor is activated
Symptoms: Behind model has been highlighted if ModelEditor is activated
Previous/Known workaround:
Solution: We changed the pick culling to not cull against the sides of the pick
box because we know the result should be in the box even if exactly on the
side because of the nature of the algorithm. It was a problem with precision.
86908 185414 Title: Isodraft - NSBC_Exceed of tube length(dimension for iso3D)
Symptoms: Incorrect NSBC length
Previous/Known workaround: set ATEXT 289.
Solution: Handle null ATEXT 289 correctly.
87091 185737 Title: Spooler - Application exit when modify Category in Paragon module
under new version of graphical library
Symptoms: Application exit when modify Category in Paragon module under
new version of graphical library
Previous/Known workaround: No known workaround.
Solution: Also added code to protect against windows which have been
deleted outside of SGL and the reference in SGL is not deleted.
86874 185910 Title: HVAC - Contours of BEND elements disappear under new version of
graphical library(DirectX)
Symptoms: When switching to a wireline view the under new version of
graphical library(DirectX), some contours of BEND elements disappear.
Previous/Known workaround: No known workaround.
Solution: The drawing code for RTORUS was missing an edge in the
wireframe case. The missing edge was added.
86742 187909 Title: Draft - ANNOTATTION PROBLEM IN ADP
Symptoms: See title.
Previous/Known workaround: No known workaround.
Solution: Automatic annotation now works for ADP as expected. The
graphics angle can be set to 90, 180, 270, 360, -90, -180, -270 or -360
degrees.
190857 Title: Piping - New 3D component creation function added
Symptoms: The user is unable to pick a component position outside the
constraints of the current centreline.
Known workaround: Not applicable
Solution: There is now a new Place3D button which allows the user to use all
of the event driven graphics functionality to pick a 3D position anywhere in the
model or screen canvas. Having created a component the model editor is
invoked to allow re-positioning.
190858 Title: Piping - The user would like to restrict non standard branch connections
to components and use conventional tee/olets in tube
Symptoms: N/A
Known workaround: N/A
Solution: The new piping settings form now has an option to exclude non
standard branch connections from tube.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 293 of 517
Product Release Letter
12.1.SP4.28

Initial Design:

Incident Issue Description


Number Number
86512, 184613, Title: Problem about the manipulation for 3D View in Surface & Compartment
87556 186773 Symptoms: Rotating,panning etc in 3D view is extrememley slow
Previous/Known workaround: None
Solution: Code change applied to resolve the issue.

Planar Hull:

Incident Issue Description


Number Number
51183 82263 Title: GUI does not appear to Modify the HOLE and Notch was defined Stiffener.
Symptoms: When trying to modify (via Planar Hull->Model->Modify), the
Statement Wizard will not start when indicating Holes or Notches in Stiffeners.
Previous/Known workaround: Manually bring up the Statement Wizard and
locate the schema line. Double click on the Schema line and the correct GUI will
be presented.
Solution: Corrected so the GUI will be presented. Also the Right Click function
for Holes and Notches in stiffeners are implemented.
51421, 84690, Title: Excess in the Bracket
70640 142274 Symptoms: Excess is not possible to given on a standard bracket.
Previous/Known workaround: Excess is posible to give on Bracket Panels.
Solution: Excess on standard brackets are implemented.
73911 151495 Title: User-defined endcut parameters does not represent in output list files
Symptoms: The parameters for User Defined Endcuts are missing in production
output files.
Previous/Known workaround: no known workaround exists.
Solution: The system will recognize the keyword output on the dataset in user
defined end cut catalogue item. The OUTPUT keyword must be set on attribute
Dtitle, like OUTPUT(A) the value which will be presented as A will be the PML
evaluation of the attribute Pproperty.
78169 164020 Title: Error modifying single stiffeners with pos number if modelled in group
(planar hull)
Symptoms: If a stiffener is modelled in a group of stiffeners and the stiffeneres
has assigned position numbers, it is then not possible to modify a single stiffener
in this group. The system response is: Not found.
Previous/Known workaround: Manually in the schema, extract the stiffener and
do modifications.
Solution: Corrected so it is possible to automatically modify a single stiffener in a
group also when position numbers are assigned to the stiffeners.
79680 168980 Title: "Modify" function resets GUI form
Symptoms: When activating a Planar Panel component via Modify function, the
pull down menues in the Statement Wizard gets empty.
Previous/Known workaround: No known workaround exists.
Solution: Previously added data in pull down menues will retain also when
modifying a Planar Panel component.
72483 171171 Title: HULLMARK Symbol display - Blank
Symptoms: when opening up the dialouge for Hullmarks and the symbol font is
to be displayed in the dialouge window, it is blank and no symbols are presented.
Previous/Known workaround: No known workaround exists.
Solution: The problem with symbol fonts not showing up in the dialouge, is
corrected and the symbols will be displayed as expected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 294 of 517
Product Release Letter
Incident Issue Description
Number Number
80338 171179 Title: BEVEL attribute is not populated in HPANBI elements
Symptoms: The bevel information is not correct in the attributes on the panel
boundaries.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the different attributes are updated with accurate
information.
171815 Title: Deletion of seams due to shifting seams or changing boundary sequence
(referenced seams)
Symptoms: Seams related to boundaries are often missed to update when
boundaries are changed.
Previous/Known workaround: Manually go through all seams in the panel when
a boundary is modified.
Solution: A warning is given when a seam is deleted due to boundary changes.
80922 172346 Title: Can't get topology point via Vitesse or PML until panel stored.
Symptoms: Data extraction is always getting data from the planar panel stored
on the data base and not the current one in memory in the current session.
Previous/Known workaround: Save the planar panel before extracting data.
Solution: In the current session, the activated planar panel will be used and not
the saved copy on the data base when extracting data via Vitesse data extraction
command.
82210 175221 Title: Impossible to cancel a flange creation operation
Symptoms: During a flange creation operation a user by mistake choose End 1
as a 'Profile section'. It is now not possible to cancel the operation and get back
to the Statement wizard.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that now Operation Complete, End of Function etc. will
bring you back to the Statement Wizard.
83945 178627 Title: GUI form error on Hole for Curve
Symptoms: when creating a Hole defined by a curve and using "As Stored", the
M1 value field is locked and any value in that file is always populated to the
statement.
Previous/Known workaround: Manually remove the value in the schema editor.
Solution: The M1 value is no longer included in the statement when the hole is a
named object and "As Stored".
84942 181040 Title: NOC noch can not be defined on three edges bracket(EDGE_3)
Symptoms: Trying to add a NOC notch to a 3 edge bracket, fails.
Previous/Known workaround: no known workaround exists.
Solution: Fixed so NOC can be given for the 3 edge bracket.
85088 181239 Title: Cannot create a bracket of BMB type via syntax 8.
Symptoms: Using a BMB bracket in other syntaxes works fine but when using
syntax 8, the system respond with an error message sayng "16117 - Unknown
toe type of bracket...Modify?"
Previous/Known workaround: Make a copy of the BMB bracket in
sbh_bracket_ctrl and call it something else (e.g. BMB8) and use this bracket in
syntax 8.
Solution: Corrected so BMB can be used also in syntax 8.
85093 181240 Title: Cannot define the material side for curved stiffener.
Symptoms: Old planar panel schemas containing a curved stiffener where MSI
keyword is included, cannot be run in AVEVA Marine 12.1.
Previous/Known workaround: Remove the keyword MSI from the statement.
Solution: A correction is made so the system will not give any error for this. The
keyword MSI has no (and will not have) effect on curved planar stiffeners.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 295 of 517
Product Release Letter
Incident Issue Description
Number Number
85648 182748 Title: The highlight colour of the selected Panel Bracket does not show as a
whole.
Symptoms: When indicate a Panel Bracket in the Statement Wizard, only one
segment is highlighted. The expectation is the whole bracket to be highlighted.
Previous/Known workaround: No known workaround exists.
Solution: Changed so the whole bracket is highlighted when indicated.
86102 183802 Title: Endcut may not be adapted to the curvature of stiffener connected to the
shell
Symptoms: The endcut type is defined in SBH_ADJUST_ENDCUT but when
stiffener is connected to the surface, it is not adjusted to the curvature.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so curvature will be reflected when defined in
SBH_ADJUST_ENDCUT.

Hull Structural Design:

Incident Issue Description


Number Number
75191 154576 Title: Hole delete operation in Production Panel doesnot propagate to design
panel
Symptoms: If holes, brackets or curves are deleted on a production panel that
had previously been updated from the design panel without the design panel
beeing activated in between, these deleted components still remaine after
updating the design panel from the production panel.
Previous/Known workaround: No known workaround exists
Solution: Corrected so the update between production panel and design panel
handle this delete operation.
85090, 181434, Title: Idealize Model(CAT-object does not exist)
85087, 181437, Symptoms: Varius issues in Idealization Model
85111, 181446, Previous/Known workaround: No known workaround.
85148 181447 Solution: Improvements have been made in the idealisation process especially
in the handling of panel boundaries. Idealised panels which fail to verify are no
longer deleted. The original boundary contour is restored even if this is not the
proper idealised contour. This is at least something that the user can modify
afterwards and it avoids unnessecary errors in referring panels.
85091, 181436, Title: Idealize Block Model inc KN Panel – Idealize Model is not created properly
85107 181443 Symptoms: Knuckled Panel not handled when idealizing a block.
Previous/Known workaround: Keep short names on sub-panels.
Solution: The check for long names in the Idealisation Settings dialogue has
been extended to subpanels to avoid this issue.
85149 181438 Title: Idealize Model – Class: GeoVector3 D: Vector is too short – Fatal error
Symptoms: System aborts during Idealization with a Fata error message: Vector
is too short.
Previous/Known workaround: No known workaround exists.
Solution: Some code has been added that checks during the idealisation if a
stiffener is so short that the stiffener ends might coincide after being snapped to
the panel limits, other stiffener ends etc. That will avoid the observed crash.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 296 of 517
Product Release Letter
Hull Production:

Incident Issue Description


Number Number
66643 126934 Title: Bevel Type 25 Wrong Cutting length in PPI
Symptoms: when giving an angle (A) in the bevel statement using a bevel type
25 (fillet version of V-joint), the resulting part is too small.
Previous/Known workaround: Possible workaround is to add excess to the limit
but this must be manually calculated each time.
Solution: Corrected so the system automatically calculates the
extension/reduction of the plate automatically.
75180 154530 Title: Enhanced Pin Jig Drawing
Symptoms: The automatic created Pin Jig Drawing might sometimes be messy.
Unfortuantly the flat structure of it makes it very difficult to do touch-up.
Known workaround: None.
Solution: The Pin Jig drawing has been enhanced in two ways;
-The drawing has a structure enabling move of e.g. the coordinate axis including
the values.
-The dimensioning are now persited enabling the use of dimensioning
modification functionality.
85450 182257 Title: Dimension placement does not display correctly on SB-side Curved panel
view.
Symptoms: The dimensioning on a Curved Panel on starboard side is not placed
on the Curved Panel.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the dimension is placed correctly on the starboard panel.
85780 182957 Title: After Knuckled Panel, Cross marking does not display on plate part.
Symptoms: Adding crossmark to a hole in a knuckled panel is not handled in the
resulting plate part.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so cross marks for holes in knuckled panels will also be
marked.
86421 184412 Title: Part size with Autobevel is different according to Node definition(ex.+,-
value for Basic bevel Type
Symptoms: Using e.g. bevel type 17 where the NOSE factor is negative (e.g. -
0.5), the plate size is not correct. There is no problem when the NOSE factor is
positive.
Previous/Known workaround: No known workaround exists. If NOSE is defined
as -0.5, then the recommendation is to use +0.5 since this gives the same and
correct end result.
Solution: Corrected so when NOSE factor is negative, the calculated plate has
the correct with/length.

Marine Drafting:

Incident Issue Description


Number Number
64577 119368 Title: User Define Hatching display out of the contour.
Symptoms: When using a User Defined Hatchpattern, it in some cases goes
outside the indicated area.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so no part of the hatch pattern is outside the indicated area.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 297 of 517
Product Release Letter
Incident Issue Description
Number Number
73049 149341 Title: 3D Event Point Snapping
Symptoms: Request the ability to customize which 3D Event Points the user is
allowed to select with 3D Event snapping to reduce the risk of errors (e.g. molded
vs. non-molded side of thickness).
Previous/Known workaround: No known workaround.
Solution: A new "picking filter" for hull models is implemented. It can be activated
by setting the new drafting default keyword "HULL_PPOINT_PLINE_PICKING" to
"MouldSideOnly". This will reduce the number of p-points and p-lines in the 3D
point modes "event points".
80288 171038 Title: Missing/Unknown Drawings in Database
Symptoms: When drawings are listed in Open Drawing form, there are some
drawings that you can select but they do not have any names or any references
to drawings in database. They are blank drawings.
Previous/Known workaround: No known workaround exsits.
Solution: A sheet without a user defined name is now being displayed by its DB-
reference number in the Open Drawing dialog.
85701 182847 Title: Guide dimension and actual dimension is displayed each differently.
Symptoms: When taken a measure and the measure is presented before it is
placed, is not the same measure that is seen when it is finaly placed in the
drawing.
Previous/Known workaround: No known workaround exists. This happens
mostly when 3 or more decimals are used in the measurement.
Solution: Problem solved, Guide dimension and actual dimension will now be
displayed the same.
85699 182850 Title: Unable to "exchange" Outfit parts, via PML, in a custom drawing directory
Symptoms: Error message saying that the model object is not found on the data
bank and that the data bank is not connected when trying to exchange Outfitting
parts via pml script.
Previous/Known workaround: The problem is caused by that fact that new
PADD databases does not have the "optional upgrade for SP3". (Admin will not
do this for you since it is not mandatory, you should be able to run 12.1.SP4
without this upgrade). So, work around is to do this upgrade which is strongly
recommended anyways (at least if all of your other database are upgraded.)
Solution: The problem is fixed, so it is possible to draw the models with MARAPI
also in a drawing of a user defined type.

Mechanical Equipment Interface (MEI):

Incident Issue Description


Number Number
70951, 142667, Title: Idealized Curved panel STEP export
83583, 181238, Symptoms: Idealised curved plates are exported with plate thickness but should
85027 181147 be exported without.
Previous/Known workaround: No known workaround exists.
Solution: Idealized curved plates are now exported as surfaces without
thickness. Please not that this will only work in projects with the
SBH_ENABLE_SOLID_PLATES option enabled.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 298 of 517
Product Release Letter
Diagrams:

Incident Issue Description


Number Number
65726 138210 Title: Shape Data is not updated on cable connection.
Symptoms: When cable is connected to eq. equipment its shape data is not
updated according to current state. The problem occurs for referenced attributes
only.
Previous/Known workaround: Manually refresh shape.
Solution: The problem has been solved and Shape Data is updated
automatically on cable connection.
79027 166756 Title: Option for labels to swith on/of following annotated shapes is needed.
Symptoms: Labels are always follwing connectors they are attached to and
there is no way to change the behaviour. The solution for 2D shapes is already
implemented.
Previous/Known workaround: None.
Solution: The existing founctionality for annotation optionally following 2D
shapes has been extended to handle connectors as well.
New option called "Move with connectors" has been added for label shapes. It
can be set in Import Shape/Edit Master dialogue and after label is dropped on
drawing, it is reflected in its context menu, so can be changed at any moment.
79447 169145 Title: SpecSearch does not change Attributes correct
Symptoms: SpecSearch does not change Attributes correctly when STYPE or
GTYPE attribute is not being set on an element.
Previous/Known workaround: set STYPE and GTYPE attributes manually
before re-spec.
Solution: STYPE and GTYPE attributes are now being properly set during
regular spec-search.
82362 175422 Title: Error whith referenced attributes for SCTUBs
Symptoms: Trying to add referenced attributes from the SCPLIN to the SCTUB
items it is displayed an error message (image) and later, the referenced attribute
shows 0 in the Shape Data. It happens the same with SCPLINE UDAs and
system attributes.
Previous/Known workaround: None.
Solution: The problem has been solved and referenced attributes window works
as expected now.
82530 175686 Title: PBS fals to present sorted nodes
Symptoms: If the PBS nodes are generated from PML function, the result
elements are not presented in order set in the function.
Previous/Known workaround: None.
Solution: The problem has been solved and the function output is presented
properly now.

Schematic 3D Integrator:

Inciden Issue Description


t Number
Number
83025 176555 Title: Diagram Change Highlighting not working correctly and crashes the
application
Symptoms: The progress bar stops part way and then there is a fatal error.
Previous/Known workaround: N/A
Solution: This has been fixed so progress completes and refreshes without
error.
85084 181233 Title: Problem with schematic model integrator and imperial project
Symptoms: Pipe name and bore values not being set correctly when imperial.
Previous/Known workaround: N/A
Solution: Fix to handle imperial values correctly in Integrator rules.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 299 of 517
Product Release Letter

Pipe Fabrication:

Inciden Issue Description


t Number
Number
77764 162477 Title: SHOP false ATTAs shown in BELRFA
Symptoms: SHOP false ATTAs show in PSPOOL.
Previous/Known workaround: None
Solution: Remove SHOP false ATTAs from BELRFA.
78954 166718 Title: Some PSPOOL validation status are reinitialized whereas the modification
didn't impact them
Symptoms: NA
Previous/Known workaround: NA
Solution: When we move flange HandleUserChanges method is invoked and
here we check whether any spoolings are required or not. If spoolings are
required we start creating pipe spools which internally tries to create pipe pieces
in that particular pipe spool. Then Spool Type is updated. When spool type is
updated there is a check for loose components (Arrive and Leave).
79754 169321 Title: Pipe component in LOOSE : fabrication excess is altered by user excess
(bad calculation of length)
Symptoms: NA
Previous/Known workaround: No known workaround.
Solution: This bug was introduced while fixing 116378. An Additional check is
introduced in PFFabricationMachineManager.cs file for checking arrive
component is coupling or not. If arrive component is not coupling or arrive
component is not weld, arrive component is loose and user access is greater
than zero then tube length is

if (!(arriveComponent.GetElementType() ==
DbElementTypeInstance.COUPLING ||
arriveComponent.GetElementType() == DbElementTypeInstance.WELD)
&& result.ArriveComponentLoose && result.UserArriveExcess > 0)
{
result.ArriveTubeLength = result.ArriveTubeLength + result.UserArriveExcess;
}
82353 175396 Title: MarineDrafting: Model Exchange claims unexpected PIPE which
containing pspool elements.
Symptoms: NA
Previous/Known workaround: None that works in all scenarios.
Solution: Marine Drafting uses now the Production Checks utility in the same
mode as when Production Checks is disabled. So no pipes/branches are getting
claimed.

Pipe Stress Interface:

Inciden Issue Description


t Number
Number
78389 176761 Title: PSI does not work with folders containing a blank space
Symptoms: PSI passes pathnames into its batch files but if the parameters
contain spaces then the are interpreted as extra parameters.
Previous/Known workaround: Do not uses spaces in pathnames
Solution: Now the parameters are passed correctly.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 300 of 517
Product Release Letter

Outfitting:

Incident Issue Description


Number Number
48321 75504 Title: Cable - Quick Routing a cable with a Bend Radius set (i.e. not 0), doesn't
put the radius on the first bend
Symptoms: First Bend radius not set.
Known workaround: Needs manual correction.
Solution: Bend radius on first bend now set.
59072, 102638, Title: Design - Storing changes back to the Naming Rules file
59073, 102641, Symptoms: Naming rule changes are always stored in %PDMSUSER%
83149 176851 Previous/Known workaround: Store changes to PDMSUSER and copy file to
project or system defaults
Solution: Ability to store changes back to the file that was opened, provided that
the user has write access.
59074 102642 Title: Design - Limit access to Rules file to user with administration privilege
Symptoms: Naming rules can only be changed by an administration user,
however, any user can change the same set of rules using the colour rules
interface.
Previous/Known workaround: Limit access to files using OS file lock.
Solution: Limit access to Rules file to user with administration privilege.
71254 143765 Title: Cable - Prelimiary and actual dressing choose different components
Symptoms: If sec allows it, can get different components selected.
Previous/Known workaround: Needs manual correction.
Solution: If there is a choice of components in the spec then the first one is
always selected.
75287, 154991, Title: Hole Management - Elliptical HE type holes added to Hole Management
79933, 169651, Symptoms: HE holes were not supported
42972 69706 Known workaround: None
Solution: New HE hole type added.
Elliptical HE type holes have been added to the standard hole list in
Design/Outfitting. HE Hole types will appear on forms where standard hole types
are selected if the HE hole data has been loaded into the Hole Management
catalogue.
When a HE hole in a Marine hull panel is approved, a HE type HHOLE is added
to the hull model.
76189 158834 Title: Isodraft - FLANge's symbol with MTOC ON isn't displayed correctly on an
isometric drawing
Symptoms: FLANge's symbol with MTOC ON isn't displayed correctly on an
isometric drawing
Previous/Known workaround: None
Solution: Take account of extra material records.
81028 175948 Title: Review - Insu representation within REVIEW (sleeve)
Symptoms: Implied tube insulation drawn solid in Review.
Previous/Known workaround: Unset GMREF for tube catalogue definition.
Solution: Now fixed.
84132 179074 Title: Isodraft - The option FallingLines OFF doesn't work
Symptoms: The option FallingLines OFF doesn't work
Previous/Known workaround: None
Solution: Store angles in 1/100ths of a degree.
84124 179203 Title: Pipe Piece name not displayed or incorrect
Symptoms: Incorrect Pipe Piece Names
Previous/Known workaround: None
Solution: Match start of Pipe Piece.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 301 of 517
Product Release Letter
Incident Issue Description
Number Number
84486 179920 Title: Gasket and Bolt are not shown in Iso drawing.
Symptoms: Gasket and Bolt are not shown in Iso drawing.
Previous/Known workaround: None
Solution: When checking if Gasket and Bolt messages are to be output - ignore
weld.
84483 180427 Title: In Paragon, the STYPE for a specification cannot be set to a string that
represents a unit. For example 'HP' cannot be used.
Symptoms: Errors occur when setting or modifying specification components
Previous/Known workaround: Use specon or speconmode
Solution: In the intermediate output file, if a number is followed by a string, the
string is explicitly marked as text.
84773 180667 Title: Capping appears incorrect in some 3D views.
Symptoms: Capping appears incorrect or inverted depending in some 3D views.
Previous/Known workaround: No known workaround.
Solution: Translucency no longer affects stencil buffer during capping stage.
85258 181618 Title: Isodraft - No angle indication for second TEE ELBOW in Isodraft
Symptoms: No angle indication for second TEE ELBOW in Isodraft
Previous/Known workaround: None
Solution: Check to see if angle is within accuracy limits.
85404 182023 Title: Customisation - Clipping backface issue
Symptoms: When clipping is on internal back faces of are not appearing.
Previous/Known workaround: None.
Solution: Turn back face culling off when clipping is on.
85418 182134 Title: Interfaces - Change of arc tolerance accuracy for batch conversion doesn't
work
Symptoms: In the exported STEP file the arc tolerance of 1 or 0.5 mm is not
taken but only the default of 10 mm.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the current representation arc tolerance will be used.
85586 182615 Title: Isodraft - Wrong offset calculation for ECC-reducer in slopelines by useing
0 Radi Bends
Symptoms: Wrong offset calculation for ECC-reducer in slopelines by useing 0
Radi Bends.
Previous/Known workaround: None
Solution: Detect zero-length bends next to eccentric reducers when calculating
offsets.
85754 183097 Title: Isodraft - Incorrect bolting for wafer connection with different bolt types
Symptoms: Incorrect bolting on isometric.
Previous/Known workaround: None
Solution: Consider Wafer Bolt Type for each Bolt Path.
86026 183501 Title: Isodraft - Outcom Label is on Wrong Item with the Option of Hyperplant
'ON'
Symptoms: Outcom Label is on Wrong Item with the Option of Hyperplant 'ON'.
Previous/Known workaround: None.
Solution: Detect position of label correctly.
86027 183502 Title: Isodraft - An unnecessary extra CutPipeLength is generated with the
option of Hyperplant 'ON'
Symptoms: An unnecessary extra CutPipeLength is generated with the option of
Hyperplant 'ON'.
Previous/Known workaround: None
Solution: If attachment attached to an non-MTO component, do not set cut
length marker.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 302 of 517
Product Release Letter
Incident Issue Description
Number Number
86066 183597 Title: Isodraft - Sheet Element and hit Element are different when hyperplant
option is on
Symptoms: Sheet Element and hit Element are different when hyperplant option
is on.
Previous/Known workaround: None
Solution: Do not split pipeline at a hyperplant record.
86416 184405 Title: Structures - Incorrect hierarchy when copying a FIXING element
Symptoms: FIXING created as a member of a FIXING and not as a sibling.
Previous/Known workaround: Using an alternative copy method.
Solution: Check for a FIXING element being copied next to a FIXING in the DB.
86836 185206 Title: Design - SHOP false ATTAs shown in BELRFA
Symptoms: SHOP false ATTAs show in PSPOOL.
Previous/Known workaround: None.
Solution: Remove SHOP false ATTAs from BELRFA.

12.1.SP4.27

Hull Production:

Incident Issue Description


Number Number
85181 181460 Title: Prtlds (l) is different in DESI / MANU fpr over CL plate
Symptoms: Partnames in DESI and MANU for SP plates is not always the same.
Previous/Known workaround: No known workaround exists.
Solution: The partname symmetry code will be calculated in a uniform way for all
plate parts. If the centre of gravity is in centreline, within 10 mms, the symmetry
code will be SP. Otherwise it will be P or S according to if the centre of gravity Y-
coordinate is positive or negative.

Pipe Fabrication:

Inciden Issue Description


t Number
Number
85021 181142 Title: Unable to generate pipe spool sketches
Symptoms: NA
Previous/Known workaround: NA
Solution: Global object aidNumbers is not loaded into memory when Marine
Drafting application is launched. Creating an instance of aidnumbers and
retrieving global instance would resolve the issue.

Outfitting:

Incident Issue Description


Number Number
79333 169421 Title: Draft - Issue related to Autodp Spools generating
Symptoms: Angled Dimensions on Pipe Sketches.
Previous/Known workaround: Manually adjust dimensions in draft.
Solution: PML change to pipesketches.pmlobj.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 303 of 517
Product Release Letter
Incident Issue Description
Number Number
84442 179726 Title: Enter key seems to work as escape key if Enter key is pressed
consecutively
Symptoms: Enter key seems to work as escape key if Enter key is pressed
consecutively.
Previous/Known workaround: Avoid pressing enter key many times as this
will eventually cancel progress.
Solution: Fixed - enter key no longer tabs to cancel button.
85215 181532 Title: Show Pipe Dimensions Does Not Work in fix 25
Symptoms: NA
Previous/Known workaround: NA
Solution: Assessed Issue. A global object
!!pipeModelDimension = object PIPEMODELDIMENSION() was declared and
drawDimension method was called using
!pipeModelDimension.drawDimension(!!ce)
and therefore it is throwing error !pipeModelDimension variable not found.
182831 Title: Incorrect pick results using ID@
Symptoms: Incorrect pick results using ID@
Previous/Known workaround: None
Solution: Fixed inconsistency in picking code.
183135 Title: Design crashes when loading E3D project containing GPWL with new
E3D Nouns
Symptoms: Load a E3D project like ACP using Design 12.1 SP4. Once it has
loaded expand any of the GPWL elements. Design will close with a fatal error.
Previous/Known workaround: None
Solution: The E3D ACP project contains some new Nouns under GPWL.
These are not in 12.1. When the code was reading the data under GPWL and
encountered one of the new Nouns it was ignoring the check that the Noun
wasn't known and carrying on instead of ignoring it and reading the next one.
184012 Title: ESC not unhighlighting picked elements
Symptoms: After pressing ESC key with left mouse down during graphical
pick highlighting is not cleared
Previous/Known workaround: None
Solution: We now ensure that highlighting is always cleared.

12.1.SP4.26

Assembly Planning:

Incident Issue Description


Number Number
74375 152466 Title: Temporary stiff. included in the Assembly
Symptoms: When assembling a Planar Panel that includes also temporary
stiffeners, those stiffeners becomes a part of the assembly.
Previous/Known workaround: Manually remove the temporary stiffeners from
the assembly.
Solution: Fixed so that temporary and fictive stiffeners are not possible to
assemble.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 304 of 517
Product Release Letter
Initial Design:

Incident Issue Description


Number Number
77723 162392 Title: Lines: Missing points from buttocks for round bow shape
Symptoms: Missing points on Section curve from Buttock curve when the
buttock curve turned around.
Previous/Known workaround: Use Clines instead or command USE FOB.
Solution: The problem has been solved so that the missing points from Buttocks
are included in the Section.
78367 164441 Title: Unable to release Initial Design data
Symptoms: Initial Design applications can't release data to design db.
Previous/Known workaround: Start Hull Design and use Log Viewer to start
initial Design applications.
Solution: Corrected so surfaces is correctly released into the design data base.
73114 164646 Title: Crash in DPDAS file import corrected
Symptoms: Application crash on importing DPDAS file.
Previous/Known workaround: No known workaround.
Solution: Code has been corrected to avoid error.
79252 167835 Title: The height of protected opening in summary table is different from GZ table
Symptoms: Reported heights in GZ-table not matching the height reported in the
report for the s-value criterion.
Previous/Known workaround: No known workaround.
Solution: Corrected so the heights in GZ-table is matching the height reported in
the report for the s-value criterion.
79622 168857 Title: PACE error in the position of the control point
Symptoms: When saving a surface in PACE the control points for a nearly plane
patch are adjusted.
Previous/Known workaround: No known workaround.
Solution: An option has been implemented to disable the adjustment.
80154 170765 Title: Grain Loading Case
Symptoms: Permissible grain heeling moments calculated and reported even
when VCG is larger than crit KG.
Previous/Known workaround: None. This is not a bug, there are different needs
depending on use.
Solution: This issue has been addressed by adding an option to the Permissible
Grain dialog for altering the report as described. It is not an error that the
moments aren't reported as zero for KGs higher than critical KG since it is not
necessarily the grain heeling moment that is critical. At the bottom of the
"Permissible Grain Moment" dialog there is now a checkbox to limit the output at
crit KG. Default is the old behaviour, to change the output to the desired tick the
check box.
80155 170904 Title: Permissible Grain Heeling Moments
Symptoms: When analysing the area between the GZ curve and the grain
heeling moment curve the area calculated were always done to the fixed upper
limit of 40 degrees heel even if the moving limit of GZMax (point of maximum
difference between the curves) is at a position less than 40 degrees.
Previous/Known workaround: Change the upper limit setting to 0, for the "From
position of GZMax" in the "Residual dynamic stability" criteria of the Grain criteria
set.
Solution: This change is added to the criteria file which is delivered.
80153 171612 Title: Grain calibration
Symptoms: Extra fill levels displayed in grain calibration table, above assumed
maximum fill level as defined in regulations.
Previous/Known workaround: None.
Solution: Max fill level assumption from regulations added as upper limit of grain
calibration by a code change.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 305 of 517
Product Release Letter

Planar Hull:

Incident Issue Description


Number Number
57646 97987 Title: X- coordinate values to FR- related
Symptoms: Always when giving an X coordinate, it is translated into an FR term.
Previous/Known workaround: No known workaround exists.
Solution: The keyword FR_TERM_OUT can be assigned the following values:
-1 No FR-terms are used.
0 FR-terms with a possible offset are used (default).
This is relevant for new panels created. Panels created in previous versions with
the option STORE_FR will still get FR terms presented.
62815 114354 Title: Separate SBH_CUTOUT_TIGHT for Flange side and Web side.
Symptoms: Enhancement
Previous/Known workaround: No known workaround.
Solution: The two new environment variables SBH_CUTOUT_TIGHT_WEB and
SBH_CUTOUT_TIGHT_FLA specify the tolerances to be used when checking
whether the profile web resp. profile flange should be welded against the cutout.
Default tolerances are 2.0 mm.
There is no change to the variable SBH_CUTOUT_TIGHT. The new variable will
however, override values given in SBH_CUTOUT_TIGHT.
68211 134674 Title: Bracket attached to another bracket does not stop at correct position.
Symptoms: Bracket attached to another bracket with flange does not stop at
correct position.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the bracket now stops at the
correct position.
68237 135226 Title: Problem not to consider the thickness of abutting plate by the CORR
keyword Symptoms: Using CORR in a boundary, referring an RSO does not give
correct result.
Previous/Known workaround: Instead of using CORR, a coordinate can be
given.
Solution: Corrected so CORR will find the outmost plate edge in the RSO and
use that when CORR is used.
71756 145624 Title: Dsgntn=HColo in HCLIP
Symptoms: The attribute Dsgntn for clps is not showing the designation but the
colour of the clip.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the true designation is presented for the attribute Dsgntn.
73118 149843 Title: Problem for the bevel side text to disappear in statement wizard when
modify the stiffener
Symptoms: Choosing MOU or Mtrl (NMOU) as bevel side from the statement
wizard would result in the opposite setting for the stiffener. Also when trying to
modify a stiffener with BVS=NMOU it would result in a blank field for bevel side in
the statement wizard.
Previous/Known workaround: no known workaround exists.
Solution: The problem is now fixed so that the results will be correct if setting
bevel side from the Statement Wizard.
73710 151039 Title: Bracket panel welded flange weight
Symptoms: The weight of a welded flange on a bracket is not included in the
bracket weight (NWEI, GWEI).
Previous/Known workaround: No known workaround exists.
Solution: Weight and CoG are calculated and added to the attributes NWEI and
GWEI so the total weight of the bracket is correct.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 306 of 517
Product Release Letter
Incident Issue Description
Number Number
74073 152044 Title: Occasional Error -4 in Hull Application
Symptoms: Using Hole Management, there is an occasional error message
"Error -4".
Previous/Known workaround: No known workaround exists.
Solution: A more detailed error message will be produced.
75656 156544 Title: Error because of BVS argument
Symptoms: When a stiffener contains the keyword BVS=MOU, the system gives
an error message about translation of tags that fails.
Previous/Known workaround: No known workaround exists.
Solution: Changes have been made so that using BVS= MOU will no longer
cause a problem.
75111 157484 Title: Scheme editor has a problem
Symptoms: Using User Defined Endcuts with many parameters will cut off the
parameter list when opening a planar panel schema.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so all parameters in UCP will be included when reopening
the schema.
77735 162395 Title: Panel store triggers (PRE & POST) not fired when creating knuckled panel
Symptoms: Using the function Planar Hull-->Panel-->Knuckled, the Pre and post
triggers are not fired.
Previous/Known workaround: No known workaround exists.
Solution: Store trigger is now fired when creating a knuckled panel.
77766 162478 Title: The tolerance of variant is not changing for chamfer.
Symptoms: The tolerance defined by TOL in the VARIANT statement in the
Bevel Control File has no affect.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the thickness tolerance will be checked against the
tolerance given in the bevel control definition (in statement VARIANT (and if
CHAMFER_ADJUST is set to 99).
77975 163606 Title: Chamfer representation wrong in symbolic views after modification of bevel
/ chamfer
Symptoms: If a bevel (via weld statement) results in a chamfer, then following
weld will also be drawn with chamfer.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so only bevel intervals containing chamfer will be displayed
with chamfer.
77447 163822 Title: Stiffener modifying has a problem in statement wizard
Symptoms: M1 value is not shown in the Statement Wizard for the Stiffener.
Previous/Known workaround: Manually add the M1 value.
Solution: When the distance value was negative it would previously not be filled
in by the StatementWizard when modifying.
78562 164981 Title: Knuckled Panel, Clip is disappeared on 3D view.
Symptoms: The clips on a Knuckled Panel is not displayed in the 3D view.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been resolved so that the Clips are seen in the 3D-
view for a knuckled panel.
79015 166730 Title: "Consider shell plate compensation" option missing in Boundary wizard
Symptoms: This option was not available through the wizard.
Previous/Known workaround: Manually update schema file with CMP keyword.
Solution: Tick box is added.
79948 169709 Title: Wrong colour of Panel Intersect symbols
Symptoms: In 12.1.SP¤ Fix.22 the colour of Panel intersect Symbol turned red
with no chance to change it.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the colour is fetched from the drafting default keyword
NOTE_COL as it did previous to Fix.22.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 307 of 517
Product Release Letter
Incident Issue Description
Number Number
80213 170651 Title: Problem not to change the value of GEN_VIEW
Symptoms: Having default keyword GEN_VIEW set to SINGLE and then change
it to ALL will not update the views.
Previous/Known workaround: Change the value in the default file and restart
the application.
Solution: When changing the default parameter GEN_VIEW from SINGLE to
ALL now all views are updated when modifying the panels.
80787 172182 Title: DIM WCOG changes the attribute GWEIGH
Symptoms: In certain cases, the weight (GWEI) is showing the weight of the
MAPLTE and not the DESI plate as required via SBH_WEIGHT_FROM_DESI.
Previous/Known workaround: No known workaround exists.
Solution: The error has been corrected and the dimensioning will show the
WCOG according to how SBH_WEIGHT_FROM_DESI is set.
80887 172306 Title: Size of SWAGE symbol is differed between STI and SWA
Symptoms: The size of the symbol for a swage defined vis the SWA statement is
smaller than if the swage is defined via the STI statement.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the height of the symbols are handled in the same way.
Please note that the definition of swage via the STI statement is unsupported.
81171 172890 Title: Folded flange is strange in 3D view
Symptoms: In some cases folded flange is drawn strange in Input Model 3D view
for customer defined flanges.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the flange is drawn correctly.
81458 173487 Title: Partname of knuckled panel doubling is wrong
Symptoms: Duplicate partnames of doublings in knuckled panel.
Previous/Known workaround: None
Solution: Corrected knuckled panel doubling partname.
82116 174989 Title: Recreate view, wrong handling of symbols for "panel intersect"
Symptoms: The "Panel Intersect" symbols are missing (or misplaced) after View
Recreate.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the panel intersect symbols does
not disappear or move.
82671 175949 Title: Bracket stiffener of knuckle panel will not display on the 3D view.
Symptoms: Creating a knuckle panel using a panel with a bracket stiffener,
bracket stiffener will not be displayed on the 3D view.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the bracket stiffener is shown in
knuckle panels on 3D view.
82714 176031 Title: Defined angle value of Boundary will gone after Apply and Deactivate.
Symptoms: When defining negative angle value of Free Boundary to create a
panel, the values will be gone after Apply and Deactivate.
Previous/Known workaround: No known workaround exists.
Solution: Correction made to keep negative angle values.
82802 176122 Title: System will inputted PQUAL for new bracket automatically if the bracket
defined without stiff
Symptoms: The keyword PQUAL is included in the bracket statement also when
there is no stiffener on the bracket.
Previous/Known workaround: Manually remove the keyword (or just let it be, it
has no effect on the bracket if no profile is valid).
Solution: The reason is that a previous stiffener had a quality defined but this
was not reset when the bracket statement is built up so the profile quality was set
to be the same as the last stiffener. This is not corrected so the quality is always
correctly fetched from the bracket stiffener and is reset if no stiffener is defined on
the bracket.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 308 of 517
Product Release Letter
Incident Issue Description
Number Number
82832 176451 Title: Vitesse holes not working
Symptoms: Vitesse holes in stiffeners and curved Panels is not working.
Previous/Known workaround: No known workaround exists.
Solution: Vitesse holes in stiffeners and curved Panels stopped working in
version 12.1.SP4 Fix.22. This is now corrected so Vitesse holes are available
also for Stiffeners and Curved Panels.
83084 176669 Title: X-direction will be opposite side in detail view.
Symptoms: when making a top view of a stiffener, the view is turned compared
to other views.
Previous/Known workaround: Manually rotate the top view.
Solution: Corrected so the top view of a stiffener will be orientated in the same
way as a side view of the stiffener.
83287 177432 Title: The position numbers of the doubling plates
Symptoms: For a symmetrical panel with a symmetrical doubling plate with
different position number for PS and SB, the different doubling plates both get the
port side position number.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the position number of the reflected doubling plate will be
correctly assigned.
83499 177758 Title: One-limit boundary
Symptoms: Not possible to create a Planar Panel with only one boundary.
Previous/Known workaround: Make sure the boundary consists of at least two
boundaries.
Solution: It is now possible to make one-limit boundaries in plane panels.
81439 178929 Title: HSTIFF with HPRHOL
Symptoms: Vitesse holes in stiffeners is not working.
Previous/Known workaround: No known workaround exists.
Solution: Vitesse holes in stiffeners stopped working in version 12.1.SP4 Fix.22.
This is now corrected so Vitesse holes are available also for Stiffeners.

Curved Hull:

Incident Issue Description


Number Number
28204, 68948, Title: Curved Panel "Dimensioning" function
57214, 100809, Symptoms: During use of the "Hull Tools -> Dimensioning" function, the user is
65609 123382 prompted to choose "PS" or "SB" for each step of measurement definition.
Previous/Known workaround: No known workaround exists.
Solution: The function is changed so the application will find out which selected
instance that are indicated.
64782 124651 Title: Weight and Cog problem about built up Tbar in curved panel
Symptoms: Weight and Cog are not separately displayed when requested by
wcog.ip WCOG_SEP_BUILT_PROF after splitting has stored the whole profile on
the profile databank.
Known workaround: None
Solution: Corrected so that separate WCOG values for web and flange are
calculated and stored also when the whole profile is stored on the profile
databank.
66574 126783 Title: Plate area is zero for converted profiles.
Symptoms: PLAREA attribute of MPLATE is zero.
Previous/Known workaround: None
Solution: Calculation of area will be done when PLAREA attribute is defined for
converted profiles.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 309 of 517
Product Release Letter
Incident Issue Description
Number Number
75066 156252 Title: It takes a very long time to recreate limit table in Curved Hull
Symptoms: -----
Previous/Known workaround: No known workaround exists.
Solution: The performance has been improved for the function to create limit
tables.
75069 157487 Title: Shell profile data has been corrupted because of unknown reason.
Symptoms: -----
Previous/Known workaround: No known workaround exists.
Solution: This happens in Renaming of a Shell Profile. The issue is corrected so
the renaming of a shell profile works as expected without corrupting the profile.
76011 157723 Title: Curved Panel "Dimensioning" function
Symptoms: when making a dimensioning with the curved Panel Dimensioning
tool, some of the dimensions is upside down.
Previous/Known workaround: Manual move the incorrect measure strings.
Solution: The problem has been solved so that the dimensions are not mirrored
depending on the direction of the measurement.
75752 157969 Title: Shell profile data has been corrupted because of unknown reason.
Symptoms: -----
Previous/Known workaround: No known workaround exists.
Solution: This happens in Renaming of a Shell Profile. The issue is corrected so
the renaming of a shell profile works as expected without corrupting the profile.
76234 158157 Title: The values of Curve and Frame ObjIds attribute in CPanParts node of
Cplate Xml have a limitation
Symptoms: when adding more than 25 curves to be marked on a Shell Plate, the
system aborts in Batch Curved Hull.
Previous/Known workaround: No known workaround exists.
Solution: There was a limit of 24 marking curves that was handled by the
system. This limit is increased to 250.
78312 164305 Title: Shell Plate Thickness Compensation Error code 204 with variable
'SBH_ENABLE_SOLID_PLATES'
Symptoms: The error is shown when creating symbolic views and the view is
then incomplete.
Previous/Known workaround: The shell plate limit table has incorrect/old shell
plates listed. To correct this please use the function "Project/ Recreate Limit
Tables". Choose shell plates as Object Type, and run the function.
Solution: Shell plate compensation has been changed to be able to handle such
incorrect objects.
78808 166224 Title: Incorrect shell plate partname shown in model info
Symptoms: Assembly definition missing in shell plate partname when shown in
model info.
Previous/Known workaround: No known workaround exists.
Solution: Shell plate partname retrieval corrected in model info function.
80911 172319 Title: Starboard Curved Panel Symbolic View – Mirrored holes
Symptoms: A curved panel view for a starboard-only curved panel displays holes
in their mirrored location as if modelled on the port side panel.
Previous/Known workaround: No known workaround exists
Solution: The problem has been solved so that the holes are drawn on Starboard
side.
81392 173311 Title: Some inclination points of shell profile are shown repeatedly after RunXML.
Symptoms: when using an XML file containing inclination points for a shell
profile, some points are duplicated in the shell profile.
Previous/Known workaround: Manually remove the duplicates.
Solution: XMl input will now remove duplicate inclination points.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 310 of 517
Product Release Letter
Incident Issue Description
Number Number
81337 175354 Title: Thickness definition on SB specific Curved plate wrong
Symptoms: Defining a shell plate with inside thickness 1.0 mm and outside
thickness > 1.0 will result in wrong graphical representation in the symbolic views.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the drawing of such plate will show the correct plate
thickness.
83285 177232 Title: When recreate Shell Expansion view, performance is too bad.
Symptoms: Create ShellX view was improved in SP4.23 but ReCreate ShellX
view still has poor performance.
Previous/Known workaround: No known workaround exists.
Solution: Recreate ShellX view performance has been improved.

Hull Structural Design:

Incident Issue Description


Number Number
68293 135821 Title: Impossible to read full RSO name in form
Symptoms: In RSO EDIT form it is impossible to read the full RSO name if it
longer than about 12chars.
Previous/Known workaround: No known workaround exists.
Solution: The prefix "_RSO_" is removed in the Edit form list, allowing 5 more
characters to be presented.
75181 154529 Title: Seam Numbers in Design and Production Panel Coincide
Symptoms: When syncing between Production Panels and Design Panels, the
seam's gets the same numbers.
Previous/Known workaround: No known workaround exists.
Solution: Handling of seam numbers after multi-view update is corrected.
75189 154569 Title: Rename Production Panel issue
Symptoms: Renaming a Production Panel in the multi-view project is sometimes
not possible.
Previous/Known workaround: No known workaround exists.
Solution: Renaming in a multi-view environment corrected.
78722 165668 Title: No error message in finite modeller if hull panels locked
Symptoms: Idealization fails if the hull panels are locked by e.g. another
designer so that Aveva Marine is not able to claim them for creating the idealized
panels.
Previous/Known workaround: Unclaim the hull panels and re-run idealization.
Solution: Fixed so no write access is needed to any hull panels.
78815 165867 Title: Adding supplementary frames
Symptoms: Inserting new frames in an existing frame table gives strange result.
Previous/Known workaround: No known workaround exists.
Solution: Corrected to handle change to non-consecutive frame numbers.
79689 169046 Title: FEM - Idealisation Write Permissions
Symptoms: Not possible to run FEM if you don't have any read/write access to a
Hull Block.
Previous/Known workaround: Make sure there is an available block with
access rights.
Solution: Fixed so no write access is needed to any Hull Blocks.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 311 of 517
Product Release Letter

Space Management:

Incident Issue Description


Number Number
79592 168729 Title: Paint area is increased
Symptoms: Paint area is increased in the latest version (12.1.4.18). Both sides
are included in the calculation.
Previous/Known workaround: No known workaround exists.
Solution: Adjusted to keep information of side in extracted model data.

Hull Production:

Incident Issue Description


Number Number
59169 102686 Title: Remove “unnecessary” table values
Symptoms: In some cases two extra pins heights are added to pin height table.
Previous/Known workaround: No known workaround.
Solution: Added new word "PINS_OUTSIDE_PLATE,<Number of Pins>,"This
word is used to control the number of pins heights that should be added outside
of the plate on each side.
Example:
PINS_OUTSIDE_PLATE,1,
This setting will give one pin height outside of plate on each side.
PINS_OUTSIDE_PLATE,0,
This will only give pin heights that are located over the plate surface. For more
information see section Enhancements above.
62428, 113415, Title: Outer contour of developed plate has been broken by hole on seam
77721 162391 Symptoms: The hole in a developed plate that is broken by a seam is not
included in the developed plate.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that holes which are intersecting
seams are included in the outer contour.
62815 114354 Title: Separate SBH_CUTOUT_TIGHT for Flange side and Web side.
Symptoms: Enhancement
Known workaround: -----
Solution: The two new environment variables SBH_CUTOUT_TIGHT_WEB and
SBH_CUTOUT_TIGHT_FLA specify the tolerances to be used when checking
whether the profile web resp. profile flange should be welded against the cutout.
Default tolerances are 2.0 mm. There is no change to the variable
SBH_CUTOUT_TIGHT. The new variable will however, override values given in
SBH_CUTOUT_TIGHT.
124143 Title: User-defined endcut missing in shell stiffener generated as plate part
Symptoms: Straight end cuts instead of user-defined endcut in shell stiffeners
generated as plate parts.
Previous/Known workaround: None
Solution: Curved panel parts generation corrected to recognize user-defined
endcut attributes.
68103 134345 Title: The GSD of Flange is not match to the GSD of Plate on SB-Side.
Symptoms: The GSD of Flange is not match to the GSD of Plate on SB-Side.
Previous/Known workaround: No known workaround exists.
Solution: Corrected reflection of flange part GSD markings.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 312 of 517
Product Release Letter
Incident Issue Description
Number Number
68208 134658 Title: The WEB marking of flange is strange on SP-panel(Over CL).
Symptoms: The marking of a welded flange belonging to a CL knuckled panel is
outside the profile in the profile sketch.
Previous/Known workaround: No known workaround exists.
Solution: Web marking on the flange is corrected.
68276 134833 Title: End segment information of EXCESS(EXCESS_VALUE = 0.0) output
position is strange on KN-Panel.
Symptoms: Excess is partly included in previous and following part limit.
Known workaround: No known workaround exists.
Solution: Plane panel parts generation corrected so that shrinkage caused by
knuckle panels seams are considered when excess is added.
68976 137124 Title: Cutout shape is incorrect with weld in Plate part.
Symptoms: In some cases, the KS notch is removed from the cutout in
ppanparts when bevel is applied to the plate.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that KS-notches in cutouts are retained when applying
weld on plate part limit. This is however, dependent on the material side on the
plate and it will give different results depending on material side, thickness and
bevel combinations.
68977 137125 Title: Missing stiffener markings on plate parts
Symptoms: Abutting stiffeners on not intersecting panels do not create markings
on plate parts.
Previous/Known workaround: None
Solution: Corrected so that abutting stiffeners on not intersecting panels are
considered when creating markings on plate parts.
138998 Title: Hole and Notch Symbols not proper in Shell Profile Sketch
Symptoms: In spite of that HOOK4 was defined in the profile restriction file
some holes/notches were marked.
Previous/Known workaround: None
Solution: The macro handling was corrected so that all holes and notches on
profiles, which type has a HOOK4-definition in the restriction file, will be not be
marked.
143200 Title: Wrong partnames for stiffeners and brackets on panels in or over CL
Symptoms: SP symmetry code not set on stiffener and bracket parts
Previous/Known workaround: None
Solution: Corrected partnames of parts from panels in/over CL.
72042 146417 Title: Mount file has opposite END1 and END2 in case of over in CL panel
Symptoms: Stiffener on the S-side of a CL panel (Y=0), the mount file has
shifted the value for END1 and END2.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so end1 and end2 is correct on both sides.
148175 Title: String Direction Error of profile in Gen.file.
Symptoms: The direction text in the STRING attribute is sometimes not correct
for Shell Stiffeners.
Previous/Known workaround: No known workaround exists.
Solution: String direction in generic files and trace direction on profile sketches
corrected for Shell Stiffeners.
73468 150378 Title: Bevel texts in profile sketch
Symptoms: Trace bevel shown as bevel code
Previous/Known workaround: No known workaround exists.
Solution: Trace bevel code in profile sketch replaced by bevel name, if existing.
73678 150957 Title: Assembly sketch for Templates doesn’t have arrow and angle symbol
Symptoms: The arrows and the angle symbol is missing in the resulting
assembly sketch from Bending Templates.
Previous/Known workaround: No known workaround exists.
Solution: The missing arrow symbols and the angle symbol are added to the
sketch.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 313 of 517
Product Release Letter
Incident Issue Description
Number Number
75569 156084 Title: The bending data of curved profile on starboard is incorrect
Symptoms: Bending data and markings are not correct for some shell profiles
located on S side on a SP Curved Panel.
Previous/Known workaround: No known workaround exists.
Solution: Markings for SP panel is corrected and also the Bending Angle is
corrected for profiles on S side on a SP Curved Panel.
75660 156329 Title: POSNO not for MPLATE
Symptoms: when adding a Position number to an Outfitting Steel part, this is not
correctly transferred to the resulting MPLATE.
Previous/Known workaround: No known workaround exists.
Solution: The Position number is now correctly handled and will be shown in the
MPLATE and also correctly handled for the Part Name (if used).
75661 156335 Title: PARNAM is not transferred correctly to Outfitting after OSP-parts-
generation Symptoms: The attribute Parnam is not correct for Outfitting Steel
parts.
Previous/Known workaround: No known workaround exists.
Solution: Proper PARNAM on outfitting plates and profiles will be set.
75804 157050 Title: INC affect to the profile sketch for Marking on the Stiffener
Symptoms: An inclined stiffener abutting another stiffener is not marked on the
profile sketch.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so markings will be created also of inclined abutting profiles.
76180 158037 Title: It does not fit the position of Sight_Line Marking with Z-plane
Symptoms: Marking line on plate does not correspond to template marking.
Previous/Known workaround: None
Solution: Correction for calculation of sight line marking on templates has been
made.
76195 158053 Title: WCOG calc. crash in 12.1.sp4.18 but fine in 12.1.sp3
Symptoms: Run wcog on a shell plate aborts the system.
Known workaround: No known workaround exists.
Solution: Problem is when a marking line in the plate is intersecting a hole more
than twice. The problem is fixed so the marking line is handled properly.
76910 160377 Title: When try to create wcog P and S side separately (block selection), there
come message "Close the program"
Symptoms: If calculate weight from block (contain mirror panels), there's no
problem, but when trying to calculate weight separate from P or S (selection
block), then there come message "Close the program" (program aborts).
Previous/Known workaround: No known workaround exists.
Solution: Corrected so that the wcog-list program doesn't abort for this type of
selection.
77266 161064 Title: Sight-Line marking position is wrong on plate parts via standard Template
Symptoms: Marking line on plate does not correspond to template marking.
Previous/Known workaround: None.
Solution: Correction for calculation of sight line marking on templates has been
made.
161094, Title: Wrong partname in generic file.
166952 Symptoms: Symmetry letters of partname generated according to centre of
gravity. Previous/Known workaround: None
Solution: Symmetry letters of partname derived from storing code except for CL
panels where centre of gravity may cause the symmetry letters to become SP.
77565 161836 Title: Wrong partnames for stiffeners and brackets on panels in or over CL
Symptoms: SP symmetry code not set on stiffener and bracket parts
Previous/Known workaround: None
Solution: Corrected partnames of parts from panels in/over CL.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 314 of 517
Product Release Letter
Incident Issue Description
Number Number
77643 162039 Title: Missing marking for Cross Templates
Symptoms: No marking lines on developed plate for cross bending template.
Previous/Known workaround: None
Solution: Corrected so missing markings on the developed plates for cross
bending templates are added.
77721 162391 Title: Outer contour of developed plate has been broken by hole on seam
Symptoms: The hole in a developed plate that is broken by a seam is not
included in the developed plate.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that holes which are intersecting
seams are included in the outer contour.
78070 163519 Title: How to set to text default font for Jig Drawing?
Symptoms: Not possible to control the text height in Jig drawing.
Previous/Known workaround: No known workaround exists.
Solution: An adjustment has been made to get the drafting text font (SBH_DEF1)
in the drawings.
75803 163636 Title: Autobevel referring to Knuckled RSO as Boundary
Symptoms: Cannot define automatic Bevel for a Panel that refers to a knuckled
RSO.
Previous/Known workaround: No known workaround exists.
Solution: Calculation of automatic bevelling along a limit can now handle multi-
face RSOs even if the face number is not given in the boundary definition.
78309, 164288, Title: SBH_MARKING_SURF_TOL does not work
82106 174955 Symptoms: Defining the tolerance via SBH_MARKING_SURF_TOL has no
effect. It always use the default tolerance of 2 mm.
Previous/Known workaround: No known workaround exists.
Solution: The problem is handled and the user defined tolerance will be used.
78481 164764 Title: Wrong COG for swaging plates
Symptoms: COG y-value wrong for plates on swaging panel.
Previous/Known workaround: No known workaround.
Solution: Calculation of COG for swaging plates corrected.
78583 165089 Title: Improvement for Frame Template_1
Symptoms: The "Sight Line" mark on each templates is not in a straight line
between first and last template.
Previous/Known workaround: No known workaround.
Solution: Corrected the calculation of the sightplane.
78584 165090 Title: Part name missing in Bending Template list
Symptoms: "Part Name" was not displayed in the ”Table of pin heights" .lst file.
Previous/Known workaround: Add level_name rule for the Bending Template
module ( PART_BENDTEMPL ) in the file assigned to environmental variable
TB_PARTNAME_LEVEL.
Solution: Part Name was not displayed in the form ”Table of pin heights” if the
level_name rule for the Bending Template module was missing in
TB_PARTNAME_LEVEL.def It is now corrected so that the application will use
“FULL” as default level_name if the statement for the Bending Template module
is missing.
78642 165246 Title: String Direction Error of profile in Gen.file.
Symptoms: The direction text in the STRING attribute is sometimes not correct
for Shell Stiffeners.
Previous/Known workaround: No known workaround exists.
Solution: String direction in generic files and trace direction on profile sketches
corrected for Shell Stiffeners.
78588 165699 Title: To Recreate Function For Developed Plate View
Symptoms: Recreate of a Developed plate view where seams has defined the
plate view, is not working. The list of seams are empty.
Previous/Known workaround: No known workaround exists.
Solution: Corrected to the Recreate View of a developed plate view is working.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 315 of 517
Product Release Letter
Incident Issue Description
Number Number
78818 165846 Title: Hull curve is not output to jig drawing on SB side.
Symptoms: An SB specific Curved Panel is used but the additional starboard
seam is not included in the Jig drawing.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the additional seam is included in the Jig drawing.
79344 168697 Title: Profile sketches not combined when combining by partname
Symptoms: Profile sketches were not combined because of very small
differences in calculated endcut angles.
Previous/Known workaround: No known workaround.
Solution: Tolerance used when comparing endcut angles corrected.
79789 169428 Title: Production sketch name with whole computer name
Symptoms: Only the last character of the computer name is used in the
production sketch name when attribute /COMPUTER is used in the naming rules.
Previous/Known workaround: No known workaround exists.
Solution: Interpretation of naming rule attribute /COMPUTER corrected.
78782 168610 Title: Paiting Area Calculation for Shell Profiles
Symptoms: Can not perform Painting Area Calculation for Shell longitudinal
profiles which are created by Hull Curve. The hull curve is a combined curve.
Previous/Known workaround: No known workaround exists.
Solution: Additions made to support the longitudinal based on a combined curve.
170236 Title: POSNO not for MPLATE
Symptoms: when adding a Position number to an Outfitting Steel part, this is not
correctly transferred to the resulting MPLATE.
Previous/Known workaround: No known workaround exists.
Solution: The Position number is now correctly handled and will be shown in the
MPLATE and also correctly handled for the Part Name (if used).
80135 170240 Title: PPI Hull selection
Symptoms: Long assembly names not visible.
Previous/Known workaround: Move horizontal scroll bar to the far right and
then autoscale the header.
Solution: The column width will be set automatically.
80175 170450 Title: Parts List report cannot be generated and Nesting Parts Menu cannot be
filled in by assembly
Symptoms: No parts list is created.
Previous/Known workaround: No known workaround exists.
Solution: A correction has been made to solve the problem so the Parts Menu
can be filtered by assembly.
80768 172062 Title: One part nesting job does not finish.
Symptoms: One-part nesting loops.
Previous/Known workaround: Skip nominal contour and all other marking line
which overlap the outer contour.
Solution: A correction has been made to avoid the loop.
81118 172839 Title: Profile template program does not work in AM12.1.SP4
Symptoms: Error 105 when last incurve is handled for the second time.
Previous/Known workaround: Remove line-feed at the end of the indata file
assigned to CARDS.
Solution: Profile template program corrected to handle extra line-feeds in indata
file assigned to CARDS.
81125 172958 Title: Plate burning to when try to start burn hole
Symptoms: The burning of holes are missing in the output of the Post Processor.
Previous/Known workaround: Replace "BURNING _DATA" with
"BURNING_DATA" (no space in the keyword).
Solution: The creation of the generic file in 3axis nesting will be corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 316 of 517
Product Release Letter
Incident Issue Description
Number Number
81216 173001 Title: WCOG for knuckled panel plate part not calculated when mode is
EXACT_WITHOUT_EXCESS
Symptoms: WCOG values are shown as zeros when WCOG_MODEis
EXACT_WITHOUT_EXCESS in the wcog.ip option file.
Previous/Known workaround: None.
Solution: Ppanparts corrected so that WCOG for knuckled panel plate parts are
calculated also when mode is EXACT_WITHOUT_EXCESS.
81507 173580 Title: Unexpected INCLINATION_ANGLE_LINE marking in generic file
Symptoms: A panel is marked by another panel that lies in a plane with a small
angle against the marked panel's plane. The attachment angle marking is then
created near the plate limit. Since the marking curve may be further cut off when
ip MARKGAP is applied the resulting marking length may be short.
Previous/Known workaround: Short marking lengths may be avoided by
defining ip MINMARKLENGTH ( default = 0.5 mm).
Solution: Panel attachment angle markings will not be generated when the
marking panel lies in a plane with a small angle against the marked panel's plane.
82860, 176601, Title: Shell profile errors in part list
84401 180055 Symptoms: Error 304 in part list log file and weight equals zero in csv-file.
Previous/Known workaround: None
Solution: Program corrected to handle shell profile model references.
82288 178778 Title: Auto bevel Application for Tight Clip
Symptoms: Some bevel for tight clips (collar plates) are not correct.
Previous/Known workaround: No known workaround exists.
Solution: Corrected for interval types 10 to 13 in user defined clips.
82296 178781 Title: Auto bevel application and colour display for Cutout
Symptoms: Colours for bevel intervals in clips (collar plates) when using "dotori"
are not displayed.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so colours for "dotori" is displayed in the symbolic view of
Clips.
84480 179870 Title: Incorrect SHAPE-value in generic file
Symptoms: Profile parts created from built profiles are getting SHAPE=T in
generic file.
Previous/Known workaround: No known workaround exists.
Solution: Corrected cpanparts so that profile type data will be correct for built
profiles.

Hull Nesting:

Incident Issue Description


Number Number
72079 146794, Title: Burning Sketch Pos No is not coming Automatically for curve panel plate
173042 Symptoms: Automatic position numbers are not automatically added to the
burning sketch for parts originating from curved plates.
Previous/Known workaround: No known workaround exists.
Solution: The issue is now fixed and burning sketch pos no is now coming
automatically also for curved panel plate.
76508 159068 Title: Unhandle rule in the nesting form (@3109)
Symptoms: Empty part ids for modelled parts when non-modelled parts are
included
Previous/Known workaround: The problem occurs only if the first part is a non-
modelled part
Solution: Corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 317 of 517
Product Release Letter
Incident Issue Description
Number Number
76351 160256 Title: PLCM nest and marking starts
Symptoms: Marking starts are moved when opening a PLCM nest.
Previous/Known workaround: Re-define the starts.
Solution: The error has been corrected. If, however, the number of contours on
the assembly part differs a lot, it might be necessary to re-define the starts.
76964 160354 Title: Missing & Wrong Bevel Texts in Nesting Sketch
Symptoms: In Plate Nesting multiple Bevel Texts are not shown.
Previous/Known workaround: Set the bevel texts manually.
Solution: Corrected so multiple Bevel texts will be placed automatically.
76965 160405 Title: Showing multiple Bevel Text in nesting sketch
Symptoms: The same bevel texts are added several times in the sketch.
Previous/Known workaround: The bevel information can be added manually.
Solution: The code is corrected so that the automatic bevel information is added
only once.
77555 161810 Title: Nesting Sketch Text and Labelling Text is shown incorrectly on Plate
Nesting.
Symptoms: In Plate Nesting the Bevel Text and Labelling Text is shown on
wrong limits.
Previous/Known workaround: Manually move the text to the correct position in
the sketch.
Solution: Corrected so the Bevel and Labelling text will be placed at the correct
limit.
77623 161999 Title: Jumping Texts and different text heights in OnePartNest sketches
Symptoms: Misplaced bevel text in burning sketch.
Previous/Known workaround: Manual rearrange the text layout.
Solution: Correction for bevel text in the burning sketch has been made.
79357 167982 Title: Total Length not correct for curve welded flanges on brackets.
Symptoms: Length is shown a zero (0) for the welded flange on a bracket.
Previous/Known workaround: No known workaround exists.
Solution: Fixed so TotLen will be correctly presented.
79554 168628 Title: Pos No problems in AM12.1 Plate Nesting.
Symptoms: Position numbers automatically placed in erroneous position or with
the wrong angle.
Previous/Known workaround: Manually move the position numbers.
Solution: The problem has been corrected.
80798 172138 Title: Converted Profiles not shown in parts menu
Symptoms: All types of plate parts are not shown in the parts menu if they have
been assembled and the weld table exists.
Previous/Known workaround: Delete the weld table.
Solution: Converted profiles will also be handled by the parts menu when a weld
table exists.
81125 172958 Title: Plate burning to when try to start burn hole
Symptoms: The burning of holes are missing in the output of the Post Processor.
Previous/Known workaround: Replace "BURNING _DATA" with
"BURNING_DATA" (no space in the keyword).
Solution: The creation of the generic file in 3axis nesting will be corrected.
81512 173585 Title: ExchangeRaw Plate Quality inconsistency
Symptoms: The erroneous quality is listed in Exchange Raw Plate.
Previous/Known workaround: It is possible (but not recommended) to change
the order of qualities in Paragon.
Solution: The code has been corrected to select the quality with exact match
(and not the first one).
81677 174247 Title: "Save" is unable after opening of read-only nesting job
Symptoms: After opening a nest in read-only mode, an old nest cannot be
saved. Previous/Known workaround: Create a new nest first and then read the
old nest. Solution: The error has been corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 318 of 517
Product Release Letter
Incident Issue Description
Number Number
82134 174987 Title: Nesting - no POSNO on curved plates.
Symptoms: Position numbers are missing in the Nesting Sketch.
Previous/Known workaround: No known workaround exists.
Solution: Fixed so position numbers from other panels are shown in the sketch.
82209 175194 Title: Position number of other panel does not appear on Burning sketch.
Symptoms: Position numbers are missing in the Nesting Sketch.
Previous/Known workaround: No known workaround exists.
Solution: Fixed so position numbers from other panels are shown in the sketch.
82575 175787 Title: Nesting - Production Date - impossible to store
Symptoms: It is not possible to give the production date.
Previous/Known workaround: No known work-around exists.
Solution: The error has been corrected. The date format is --: 2015-07-23.
82686 176001 Title: RAWPLA Name Length causes Hull Design process to fail at start.
Symptoms: An error occurs at start-up.
Previous/Known workaround: Make sure that no raw plate name in the
Catalogue is longer than 25 characters.
Solution: The name of raw plates with names longer than 25 characters will be
truncated to 25 characters at Nesting start-up. There will be no check if the
resulting name is ambiguous. The object in the Catalogue will not be changed.
83098 176706 Title: Table for parts posno in nesting
Symptoms: Only 5 columns of the same $-value is possible.
Previous/Known workaround: No known work-around exists.
Solution: The possible number of columns has been increased to 25.
84511 180151 Title: Extracted Nesting Verification date returns "Plate in work".
Symptoms: Using Data extraction to extract the Verification date does not return
the date but instead returns "Plate in work".
Previous/Known workaround: Verify the plate once more.
Solution: Corrected so the Verification date is extracted correctly in Data
Extraction.

Hull Weld Planning:

Incident Issue Description


Number Number
78193 163854 Title: Unnecessary weld at Shell Stiffeners
Symptoms: When run Detect Weld, there is some unnecessary weld for shell
stiffeners.
Previous/Known workaround: No known workaround exists.
Solution: The unnecessary weld will not occur.
82425, 175491, Title: The Weld of shell profile end is omitting on both side.
82426 175492 Symptoms: Some welds between shell profile ends are missing.
Previous/Known workaround: No known work-around exists.
Solution: The code has been corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 319 of 517
Product Release Letter

Marine Drafting:

Incide Issue Description


nt Numb
Numb er
er
37504, 63830, Title: The arrow in Dimensioning is not persisted
39162, 65152, Symptoms: When moving a dimension, the arrow is always flipped back.
57171, 98386, Previous/Known workaround: Manually flip the arrow
63837 117081 Solution: A solution for the "flip arrow" persistence is now available.
1. Modify/Dimension/Flip Arrow will now persist the result in linear dimensionings.
In other types of persisted dimensionings (like Angle, Radius etc), the arrow flip
will still not be persisted.
2. A new function Modify/Dimension/Hide/Unhide Arrow has been introduced This
function is used to disable/enable dimension arrows and is applicable in
persisted linear dimensionings (the result will then be persisted) (in other types
of dimensionings (persisted or not persisted) the function is not applicable).
69329 138200 Title: MARAPI function DwgDelete does not work when a DB-reference string is
given as drawing name
Symptoms: The drawing is not deleted
Previous/Known workaround: Give the drawing name instead of DB-reference.
This will unfortunately not work if the name is longer than 26 chars or contains lower
case characters.
Solution: DwgDelete accepts the DB-reference string as input.
71406, 144457, Title: Wrong WCOG value
83728 178209 Symptoms: Using the Dimension -> WCoG function on an Assembly gives wrong
result. It takes the whole panels even if only a part is included in the assembly.
Previous/Known workaround: No known workaround exists.
Solution: Made sure assembly as such is treated and not the assigned parts. If
assembly exists in drawlist of drawing and selection is switched to view level user is
asked whether assembly or model is meant for selection. It is not possible to mix
assemblies and models in the same selection.
72265, 147173, Title: Controlling colours of butting stiffeners via LT object
84421 179676 Symptoms: Abuting stiffeners has fixed colours in symbolic views (blue (os)/white
(ts))
Previous/Known workaround: No known workaround exists.
Solution: Two new statements have been added to the LT object, STI_ABUT_TS
and STI_ABUT_OS.
Example of use:
STI_ABUT_TS/LT='DashedDotted'/COL_DESIGN='DimGrey'/COL_PROD='Red'/LA
YER=6005;
STI_ABUT_OS/LT='Dashed'/COL_DESIGN='DimGrey'/COL_PROD='DimGrey'/LAY
ER=6006;
72430 147465 Title: Read only mode does not work at MarAPI
Symptoms: Drawing is claimed when opening as Read Only via API.
Previous/Known workaround: No known workaround exists.
Solution: There is a new marapi function called DwgOpenAsCopy:
DwgOpenAsCopy( String DwgName, String CopyDwgName, Real CopyDwgType)
Input Arguments: 1. DwgName - Name of drawing to copy and open 3.
CopyDwgName - Name of drawing copy 4. CopyDwgType - Drawing type of the
new copy. Can be give as "DwgType". Note that "-1" has the meaning "same type
as the source drawing" The function only works for drawings stored in the PADD
database (therefore there is no drawing type argument for the source drawing, it is
fully identified by its name) (DwgOpenAsCopy is only implemented in MARAPI and
not in Vitesse).

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 320 of 517
Product Release Letter
Incide Issue Description
nt Numb
Numb er
er
73111 149507 Title: Problem for drawing to increase database session and drawing object
file(SDB) without the change
Symptoms: Whenever saving a drawing without any changes, the version of the
.sdb file is increasing.
Previous/Known workaround: No known workaround exists.
Solution: If only the current window (zoom and pan operations) have been
changed, the version of the SDB file will not increase when drawing is saved.
74446 153595 Title: Empty view element is created in Draft Explorer after splitting subpicture.
Symptoms: Empty view element is created in Draft Explorer after splitting
subpicture.
Previous/Known workaround: No known workaround exists.
Solution: The VIEW was empty because owned VNOT elements were not copied
as it should. This has been corrected.
75291 154993 Title: How to measuring a diagonal (space length) Length?
Symptoms: The 3D point "Intersect Curved Hull Models" does not work, it just gives
the message "Invalid function".
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the space length (3D dimensioning) works for Curved Hull
Objects.
75987 157692 Title: A fatal error occurs when insert a Flange which use dataset in catalogue.
Symptoms: See title.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the Flange will be inserted and system will not abort.
159539 Title: Enable sectioning and slicing for 'Wireline hidden-line' view type
Symptoms: 'Wireline hidden-line' is currently ignoring section planes (like true
wireline).
Previous/Known workaround: No known workaround exists.
Solution: View type 'Wireline hidden-line' will now handle section planes (incl slice)
in both Marine and Plant. Using this view type instead of Local Hidden Line will give
a better performance.
76989 160357 Title: "Modify>Copy>Subpicture" to copy Subpicture level 3 shouldn't copy
Backdrop.
Symptoms: When copying a View containing Backdrop information, the Backdrop
information should not be included.
Previous/Known workaround: No known workaround exists.
Solution: When copying subpictures below view level to a new view, the backdrop
information will not be copied anymore (however, when copying a view, the
backdrop information will still be copied).
76928 160535 Title: The arrow in Dimensioning is not persisted
Symptoms: When moving a dimension, the arrow is always flipped back.
Previous/Known workaround: Manually flip the arrow.
Solution: A solution for the "flip arrow" persistence is now available.
1. Modify/Dimension/Flip Arrow will now persist the result in linear dimensionings. In
other types of persisted dimensionings (like Angle, Radius etc), the arrow flip will still
not be persisted.
2. A new function Modify/Dimension/Hide/Unhide Arrow has been introduced This
function is used to disable/enable dimension arrows and is applicable in persisted
linear dimensionings (the result will then be persisted) (in other types of
dimensionings (persisted or not persisted) the function is not applicable).

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 321 of 517
Product Release Letter
Incide Issue Description
nt Numb
Numb er
er
77719 162389 Title: Outfitting model cannot be inserted into the Read-only drawing
Symptoms: It is not possible to add outfitting models into a Read Only drawing. Hull
objects are ok to add.
Previous/Known workaround: Copy the drawing and open the copy as an ordinary
drawing.
Solution: A new possibility to open a drawing as a copy of an existing drawing has
been implemented. This copy is in "new state" which means that if the drawing is
closed without saving, it be deleted again.
78098 163637 Title: Marenvutil usage, multi setting in one line
Symptoms: For each command when using Marenvutil, the splash screen pops up.
Time consuming.
Previous/Known workaround: No known workaround exists.
Solution: Two fixes:
1. marenvutil.exe will no longer display a splash screen if batch mode is used.
2. Multiple occurrences of the 'set', 'unset' and 'remove' can be passed on the
command line e.g.: marenvutil.exe -project MAR -set SB_BACK_COL=BLUE -set
SB_REF_COL=YELLOW -set
SBD_DEF1=C:\AVEVA\Marine\Projects12.1.SP4\Mar\marmar\def\sbd_def1_ay.def
78357 164429 Title: Cannot select equipment as a subview after migrating
Symptoms: Cannot select equipment as a subview after migrating.
Previous/Known workaround: No known workaround.
Solution: A new function Tools/Model/Transform has been implemented. The
behaviour when selecting outfitting models is similar to already existing function
Tools/Model/Delete, i.e. the Drafting default keyword AUTO_OUTFITTING_LEVEL
is trigged for optional transformation on high design level ( e.g. when identifying a
"Pipe Branch" model subview, all model subviews belonging to the owner Pipe are
transformed)
78237 165083 Title: A fatal error occurs when insert a Flange which use dataset in catalogue.
Symptoms: See title.
Known workaround: No known workaround exists.
Solution: Corrected so the Flange will be inserted and system will not abort.
80180 170395 Title: Move dimension does not work after update view
Symptoms: After updating a view, any angular, radius or diameter dimension that
has been modified, is reverted back to original position.
Previous/Known workaround: No known workaround exists.
Solution: The function "Modify/Dimension/Move dimension text" now persists the
result also for angular/radius & diameter dimensioning’s.
170906 Title: Problem for the geometries to disappear during MouseWheelZoom
Symptoms: Zooming in by using the Mouse Wheel Zoom makes some entities to
disappear.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so no entities are missing in the zoom activity.
81938 174708 Title: Problem for the geometries to disappear during MouseWheelZoom
Symptoms: Zooming in by using the Mouse Wheel Zoom makes some entities to
disappear.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so no entities are missing in the zoom activity.
81962 174760 Title: View is strange when you use Slice function for slot area.
Symptoms: If the Slice is within a cutout, the view becomes very strange.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that slicing view when one points is
inside the cutout is good.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 322 of 517
Product Release Letter
Incide Issue Description
nt Numb
Numb er
er
82193, 175144, Title: The symbolic view does not get the correct representation style
84270 179398 Symptoms: The "RRSF" attribute of the VIEW element in PADD does not have
value that was selected in the create symbolic view dialog.
Previous/Known workaround: To change the representation style via "Drawing
Explorer", select the view and use "Properties" in the context menu.
Solution: The value is not set correctly for the new symbolic view.
83030 176565 Title: Problem for the geometries to disappear during MouseWheelZoom
Symptoms: Zooming in by using the Mouse Wheel Zoom makes some entities to
disappear.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so no entities are missing in the zoom activity.
83467 177730 Title: Problem for the geometries to disappear during MouseWheelZoom
Symptoms: Zooming in by using the Mouse Wheel Zoom makes some entities to
disappear.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so no entities are missing in the zoom activity.
84087 178952 Title: Problem for the geometries to disappear during MouseWheelZoom
Symptoms: Zooming in by using the Mouse Wheel Zoom makes some entities to
disappear.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so no entities are missing in the zoom activity.

Design Reuse:

Incident Issue Description


Number Number
69685 139065 Title: Imported auto drawing via Design Reuse is copied to the Standard Auto
drawing hierarchy.
Symptoms: Imported auto drawing via Design Reuse is copied to the Standard
Auto drawing hierarchy.
Previous/Known workaround: No known workaround exists.
Solution: A new option has been added, Location. If set to "Explicit" the drawing
will be stored explicitly in the dept/regi as in the source project. If set to
“ByDwgType” the drawing will be stored in dept/regi as defined by the general
storing and organization mechanism based on drawing type.

Mechanical Equipment Interface (MEI):

Incident Issue Description


Number Number
78414 167346 Title: MCAD Step Export multiple bodies for Knuckled panel
Symptoms: Exporting Step 203 from a Knuckled panel with 3 or more subpanels
leads to multiple bodies in the result. The parts are doubled in the mid part of the
panel.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that multiple bodies are not exported.
80431 171343 Title: SHI-Defect of IGES output by macro
Symptoms: IGES is not output correctly except the header. Although an IGES
file is created, the size is 1KB (too small).
Previous/Known workaround: None
Solution: The IGES export function has been corrected and the geometry is now
exported.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 323 of 517
Product Release Letter

Diagrams:

Incident Issue Description


Number Number
77656 162059 Title: Pagearray pseudo attribute not correctly filled when inserting and deleting
new pages.
Symptoms: Pagearray pseudo attribute not correctly filled when inserting and
deleting new pages.
Previous/Known workaround: None.
Solution: Pagearray and diarefarray are now being updated reordering pages.
80446 171400 Title: Auto electrical connection
Symptoms: 1) User has to manually drag and drop electrical connection when
he wants to connect cable to equipment.
2) There is no easy way to update existing drawing about electrical connection
between direct cable to equipment connection.
Previous/Known workaround: Manually open drawing and add electrical
connection.
Solution: Auto create electrical connection has been implemented.
83050 176596 Title: Grouped shapes from Stencil are not created in the Database any more
Symptoms: Grouped shapes from Stencil are not created in the Database any
more
Previous/Known workaround: Define shapes manually.
Solution: The ability of defining shapes moved to stencil from drawing has been
restored.
83063 176618 Title: Diagrams Options should be possible to be controlled from PML level
Symptoms: There is no way of controlling Diagrams Options from PML level.
Previous/Known workaround: Implement custom PML-callable dll.
Solution: New PML-callable object called PMLSettingsManager has been
implemented. It is located in Aveva.Diagrams dll (namespace
Aveva.Diagrams.PMLTools) and has following methods to be used in PML:
-getSetting(string settingKey) that is returning value of setting with given key. the
value is returned as text
-setSetting(string settingKey, string newValue) that is setting new value (given as
text) for setting with given key
The keys of settings are available in DiagramsDefaultSettings.xml.
Also two sample PML functions: getDiagramsOption.pmlfnc and
setDiagramsOption.pmlfnc has been added as example of usage of the new
functionality.

Engineering:

Incident Issue Description


Number Number
64698 120160 Title: Tags - q !!ce.Backref is returning only the first element of the array
Symptoms: Querying an array attribute, that has an optional qualifier, without a
qualifier will return a single result.
Previous/Known workaround: Query the attribute with empty qualifier, for
example q var !!ce.attribute('BACKREF', ARRAY())
Solution: The query will now return the full array when no qualifiers are given.
70935 142646 Title: "Select Rows" functionality in status graphic viewer doesn't work.
Symptoms: "Select Rows" functionality in status graphic viewer doesn't work.
Previous/Known workaround: None.
Solution: "Select Rows" functionality is not corrected and works as expected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 324 of 517
Product Release Letter
Incident Issue Description
Number Number
76402 158606 Title: Engineering 3D viewer not showing item when using Imperial Units
Symptoms: Engineering 3D viewer not showing item when using Imperial Units.
Previous/Known workaround: Do not set imperial units as distance.
Solution: Changed the way some methods in Viewer3D are invoked as Mac
suggested.
77538 168958, Title: Schematics Model Manager - Units are not converted as expected
161684 Symptoms: Attribute values are imported with the wrong units
Previous/Known workaround: N/A
Solution: Units converted correctly.

Multi-Discipline Supports (MDS):

Incident Issue Description


Number Number
74350 152431 Title: E3D Model 1.1 (MDS) deletes all association elements found on a STRU -
also non MDS associations
Symptoms: association data other than MDS data is deleted when handling
stru's in MDS.
Known workaround: No known workaround.
Solution: update code to look for the MDS purpose when considering
associations for deletion.
81581 173779 Title: Weld tags not displaying at weld point on drawing
Symptoms: Weld tags on MDS/ABA drawings incorrectly positions.
Previous/Known workaround: None
Solution: Fixed weld tagging code to correctly identify the weld positions.
81825 174417 Title: MTO on MDSABA drawing not showing all ancillaries
Symptoms: Correct number of MTO items not present and incorrect descriptions
evident.
Previous/Known workaround: None
Solution: Problems with ancillary MTO fixed in MDS drawings.

Outfitting:

Incident Issue Description


Number Number
41809 66299 Title: HVAC - Selecting multiple components to add to a spool
Symptoms: Enhancement, to speed up picking of elements in spool.
Previous/Known workaround: Pick elements one by one. (Still available).
Solution: New gadget on form 'Add Spool Elements (by picking last only)'.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 325 of 517
Product Release Letter
Incident Issue Description
Number Number
52871 87305 Title: Draft - Attempting to open E3D Drawing in PDMS Draft gives empty
read-only Ref window
Symptoms: On attempting to open a DRAWING with any transformed E3D
DRAW sheets, the Main Display is cleared, cursor hidden and title updated for
a transformed sheet, even though the sheet correctly cannot be opened. This
causes confusion as it appears that the sheet can be opened. The problem
does not occur when opening individual sheets (as of 12.1.SP2.20)
Previous/Known workaround: No known workaround.
Solution: This has been fixed so that when opening a DRAWING containing
one or more AVEVA E3D DRAW sheets, these are ignored and only the
PDMS DRAFT sheets are opened. In addition the standard 'open multiple
sheets' confirmation prompt is replaced with the prompt: ''AVEVA E3D Draw
sheets will be skipped. Do you wish to add the other sheets to the view?''. If
there are only AVEVA E3D DRAW sheets under the DRAWING then an error
is displayed instead: 'Cannot display any sheets under the current drawing as
they can only be accessed using AVEVA E3D Draw'.
62970 114743 Title: Status Controller grid not getting refreshed on Edit Status
Symptoms: Grid not updated automatically following edit status operation
Previous/Known workaround: Refresh grid from column title right click menu
Solution: Grid now refreshes automatically following edit status.
62726 114996 Title: Quick Pipe Router now handles cases when BendMacReference is not
set
Symptoms: Null-radius bends created
Previous/Known workaround: No known workaround.
Solution: The application will now check BendMacReference of the current
branch, pipe or zone, and if it is not assigned, the user will be requested to
choose a bending machine from those available in the project or select a
default bend radius factor (radius = outside diameter * factor). The default
bend radius factor is used for the current session on all pipes/branches that
have BendMacReference unassigned. If BendMacReference is assigned on a
pipe/branch, it is used instead of the default radius factor.
NB: The users are advised to assign bending machines wherever possible,
since the use of an explicitly specified bend radius factor is not subjected to
the same rigorous suitability tests as in Pipe Fabrication or Production Checks.
66349 127625 Title: Issues with drawing very large structures
Symptoms: Very large structures consisting of FRMW elements with
thousands of subelements have caused issues when drawn in DRAFT VIEWs.
These include a warning about internal limits being exceeded, missing ppoints
and potentially missing elements in the drawing.
Previous/Known workaround: Divide the framework (FRMW) into sub-
frameworks (SBFR)
Solution: The subelement limit for large FRMW has been raised to 21000 and
within this limit there should be no more issues with ppoints being dropped or
elements not drawn. Note however that having so many elements under a
FRMW is still not recommended. Where possible large FRMW (over 1000
subelements)should be created owning multiple subframeworks (SBFR)
instead, each of which should have a limited number of (say 1000)
subelements. This should also inprove the general responsiveness of the
application, for example picking ppoints and use of the design explorer.
69880 140379 Title: Cable - Allow for display control of the Cabling Application Defaults
Symptoms: When Outfitting is configured to the Cabling System then the
Cabling Application Defaults form automatically launches every time the
application starts.
Previous/Known workaround: No known workaround.
Solution: The problem is fixed. Now the cabling default does not popup every
time when Cabling Application is launched.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 326 of 517
Product Release Letter
Incident Issue Description
Number Number
70299 141034 Title: Spool number on isometric pointing to wrong element
Symptoms: Spool number on isometric pointing to wrong element.
Previous/Known workaround: None
Solution: Take account of crosses when checking to see if the last spool
number record needs to be output.
71668, 145388, Title: Structures - BPANEL is not located corre3ct in the 3D view
71675, 145397, Symptoms: -----
71723 145582 Previous/Known workaround: No known workaround exists.
Solution: Corrected so the BPANEL is placed correct in the 3D view also
when it is below a TMPL.
75183 156082 Title: Spooler - NSBC-Wall thickness error, PTAP different spec.
Symptoms: Datacon PTAP warning.
Previous/Known workaround: Ignore warning.
Solution: PTAP warning removed.
77748 162439 Title: Equipment - BPANEL is not located corre3ct in the 3D view
Symptoms: -----
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the BPANEL is placed correct in the 3D view also
when it is below a TMPL.
77947 163057 Title: Design - Control display of PPIECE names
Symptoms: PPIECE names appear in both Cut List and Tags.
Previous/Known workaround: No known workaround.
Solution: New PPIECE command options.
78145 163819 Title: Isodraft - Missing Non-standard branch connection orientation axes
(xyz) and info label
Symptoms: Missing Non-standard branch connection orientation axes (xyz)
and info label.
Previous/Known workaround: None
Solution: Place correct Non-standard branch connection orientation axes
(xyz) and info label.
74324 164703 Title: Spool - Error of Spool Split
Symptoms: Error of Spool Split.
Previous/Known workaround: No known workaround.
Solution: When there are multiple branches we need to re initialize sequence
number to 0 in LoadSpools method so that when next branch is processed it
will try to retrieve correct element.
77990 165061 Title: Piping - PDMS crashes (dab error 10) when evaluating BRWEIG
Symptoms: PDMS crashes (dab error 10) when evaluating BRWEIG.
Previous/Known workaround: Correct LSTU bad refs.
Solution: Now checks properly.
78663 165473 Title: Flange allowance doubled if Pipe Fabrication used
Symptoms: Flange allowance doubled
Previous/Known workaround: No known workaround.
Solution: Loose Flange allowance already included in Pipe Piece
:PFCUTLENGTH - ignore if Pipe has PPIECE records.
78940 166617 Title: Building Applications - Room Manager - Piping Insulation Thickness
Symptoms: Application does not take into account the pipe insulation
thickness to calculate the volume.
Previous/Known workaround: No known workaround.
Solution: Updated to take into include pipe insulation in volume calculations.
74697 169167 Title: Isodraft - Missing of Gasket Label in ISO drawing in sp 4.15
Symptoms: Missing of Gasket Label in ISO drawing in sp 4.15.
Previous/Known workaround: No known workaround.
Solution: Do not process another gasket if there is still one awaiting to be
processed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 327 of 517
Product Release Letter
Incident Issue Description
Number Number
79779 169329 Title: Structures - Cannot use BY or model editor on SCTN that contains FITT
or SJOI with TMPL
Symptoms: Gives error if TMPL is locked.
Previous/Known workaround: Unlock TMPL.
Solution: Now works.
79987 169765 Title: Structures - No SPREF for a BPANEL element
Symptoms: BPANEL does not have a SPREF
Previous/Known workaround: No known workaround exists.
Solution: SPREF attribute has been added to BPANEL.
Create BPANEL will copy the SPREF attribute from the first PANE.
Split BPANEL will copy the SPREF attribute to the PANEs.
80090 170256 Title: Equipment - Nozzle - Reserved volume representation
Symptoms: Nozzle - Reserved volume drawn solid
Previous/Known workaround: None
Solution: Fixed.
79900 170262 Title: Design - SCTN Not Exporting Correctly At Lev11 - Should be No
Geometry
Symptoms: SCTN centre lines badly transformed
Previous/Known workaround: None
Solution: Transform corrected.
80430 171511 Title: Design - weight difference affected by arc tolerance
Symptoms: Changing graphical quality changes mass properties.
Previous/Known workaround: Don't change graphical settings.
Solution: a new Mass Property arc tolerance added.
81537 173749 Title: Structures - No SPREF for a BPANEL element
Symptoms: BPANEL does not have a SPREF.
Previous/Known workaround: no known workaround exists.
Solution: SPREF attribute has been added to BPANEL.
Create BPANEL will copy the SPREF attribute from the first PANE. Split
BPANEL will copy the SPREF attribute to the PANEs.
82163 175076 Title: Isodraft - Wrong Weld on reduced (blind) flange in isometric
Symptoms: Wrong Weld on reduced (blind) flange in isometric.
Previous/Known workaround: None
Solution: Look in appropriate direction to see if there is an end condition of
'SC' specified.
82385 175611 Title: Isodraft - [BUG] CoFormat Ship
Symptoms: Incorrect Ship's co-ordinates.
Previous/Known workaround: None
Solution: If this is a weld without Ship's Co-ordinates (inserted weld for
instance), always pick up start Ship's Co-ordinates from following record
unless that is also a coincident weld.
175692 Title: Isodraft - Isodraw aborts when invalid Weld Table specified
Symptoms: Isodraw aborts when invalid Weld Table specified
Previous/Known workaround: None
Solution: Check for missing weld information.
82775 176112 Title: Isodraft - NSBC - No orientation if dimensions are on for the tappings
Symptoms: NSBC - No orientation if dimensions are on for the tappings.
Previous/Known workaround: None.
Solution: NSBC - Show orientation if dimensions are on for the tappings.
82824 176190 Title: Isodraft - Incorrect position of some ATEXT’s with non-English
characters
Symptoms: Incorrect position of some ATEXT’s with non-English characters
Previous/Known workaround: None
Solution: Use printable length when calculating start column - not number of
bytes!

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 328 of 517
Product Release Letter
Incident Issue Description
Number Number
83071 176652 Title: Problems some char in DXF exported from Isodraft
Symptoms: Two characters not exported correctly on export.
Previous/Known workaround: No known workaround
Solution: Code now handles the two characters correctly.
176659 Title: 3D view shows graphical artefacts at large coordinates
Symptoms: Vertices of elements which are a large distance from the origin
sometimes appear displaced relative to other vertices in the same element.
Previous/Known workaround: None.
Solution: Double precision matrices are now used for transformations which
then are dynamically adjusted with a single precision floating origin when
rendered to the 3D view. This reduces rounding errors with single precision
and eliminates the observed rendering issues.
82545 176831 Title: Isodraft - Problem with Ship Coordinate for Pipe Isometric Option
Symptoms: Wrong Ship Coordinates displayed.
Previous/Known workaround: Remove flow arrows.
Solution: Select correct Ship Coordinates.
177710 Title: Isodraft - Isodraft aborts when options SPOOLN FROMDB and
PSNAME OFF are used for a Design isomeric
Symptoms: Isodraft aborts.
Previous/Known workaround: Use SPOOLN ON or PSNAME ON.
Solution: Generate a blank Spool Number under these circumstances.
81600 178300 Title: Building Applications - Concrete Quantities - Incorrect Formwork Area
Calculation
Symptoms: For some concrete elements, results for formwork areas are
incorrect.
Previous/Known workaround: None.
Solution: Formwork area calculations have been fixed.
83237 179021 Title: Design - PPIECE cutting length not shown when COUP at start of
branch
Symptoms: PPIECE cutting length not shown on isometric
Previous/Known workaround: No known workaround.
Solution: Cater for PPIECE AELRFA setting in this instance.
84474, 179864, Title: World axes labels sometimes disappear
84639, 180594, Symptoms: World axes labels disappear from 3D view typically when working
84910 181163 far away from the origin.
Previous/Known workaround: No known workaround.
Solution: World axes labels now culled correctly irrespective of 3D view
position.
84640 180380 Title: Capping rendering incorrect for some views
Symptoms: When capping is enabled for a clipped view, caps are not
rendered correctly. This only occurs with optimised graphic engine
introduced with fix 25.
Previous/Known workaround: None.
Solution: Render composition flag not being reset between translucent and
capping render passes.
85009, 181090, Title: Continuation Bolts missing
85043, 181171, Symptoms: Missing Bolts
84732 180659 Previous/Known workaround: None
Solution: Show continuation Bolts with Gasket.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 329 of 517
Product Release Letter

Consolidated from previous fix releases:

12.1.SP4.25

Diagrams:

Incident Defect Description


Number Number
58711 101617 Title: Replace background in batch mode
Symptoms: User wants to replace background in batch mode.
Previous/Known workaround: Usage linked objects as background.
Solution: New feature has been implemented. For further information please
refer to section Enhancements at the beginning of this document.
78911 166464 Title: Line type displayed improperly
Symptoms: When drawing exported in mm some line patterns that were mapped
to build in patterns does not looks in AutoCad as expected.
Previous/Known workaround: 1) Set LTSCALE in auto cad to proper value. 2)
Add/modify Diagrams.lin file.
Solution: New option has been introduced where user can set LTSCALE factor.

Pipe Fabrication:

Inciden Issue Description


t Number
Number
57866 98046 Title: Galvanisation Tank Check Limitation.
Symptoms: N/A
Previous/Known workaround: NA
Solution: New default check for attribute selection in galvanization form has
been implemented.
60025 105121 Title: End/Feed Excess Aids Removed when Selecting Spools
Symptoms: N/A
Previous/Known workaround: None
Solution: The issue has been fixed - identifying the aid number to be switched
off instead of clearing all the aids.
60784 107902 Title: Weld Handling Form - Modify Welds
Symptoms: N/A
Previous/Known workaround: None
Solution: Functionality to pick and modify welds has been implemented whereby
specific welds or multiple welds can be modified using this selection. There is no
need to stand on a weld as found previously.
64096 117700 Title: User Feed Excess Form Feedback Required
Symptoms: N/A
Known workaround: N/A
Solution: New functionality to identify the grip value has been implemented. For
further information please refer to section Enhancements at the beginning of this
document.
65293 122323 Title: Fabrication Manager Form Layout/Behaviour
Symptoms: N/A
Previous/Known workaround: None
Solution: The entire grid is not refreshed when a new element is created.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 330 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
69998 140241 Title: Penetration ATTA placed next to a COUP generates new PSPOOL when
pipe Validate
Symptoms: This is a specific scenario for flanged coupling.
Previous/Known workaround: None
Solution: An element is added to the component list where the element type is
an attachment and on retrieving the shop of the next element; comparing to
ensure it is not equal to false.
72008 146363 Title: Limits added by users are not recognized by Multiple Spool feature in Pipe
Fabrication.
Symptoms: Limits are not recognized during addition of spools to Spool
Drawings.
Previous/Known workaround: None
Solution: The program modified to recognize the spool limits added by users.
75351 155152 Title: The Galvanization Tank Check form fails to open on the attached pipe.
Symptoms: N/A
Previous/Known workaround: N/A
Solution: The program has been modified so that on calculating the flowdir, if
frompos and topos are equal, it is calculated using component Reference
pDirection w.r.t World.
75353 155224 Title: Incorrect Assignment of the Bending Machine
Symptoms: N/A
Previous/Known workaround: N/A
Solution: Branch is given the first priority for the assigning of the Bending
Machine. If this does not result in the Bending Machine being assigned, the
check continues to the Pipe and then to the Zone.
75387 155231 Title: Error message changed for Fabrication Isometric extraction
Symptoms: None
Previous/Known workaround: None
Solution: Code modified to display the error message as ‘Error occurred in
isometric creation. Please refer to the Command Window.’.
75398 155266 Title: Multiple Spool Error Adding when Shop Equals False of the First
Component
Symptoms: If the first component's shop is false and it has a tube, the multiple
spool function works incorrectly.
Previous/Known workaround: None
Solution: The program has been modified to ascertain the first tube correctly if a
first component's shop is false.
75760 157095 Title: Error in assigning bending machine
Symptoms: N/A
Previous/Known workaround: None
Solution: : Issue has been resolved by applying a rounding to the wall thickness
to two digits.
78755 166244 Title: Bending infos in format of XYZ is fixed
Symptoms: NA
Previous/Known workaround: None
Solution: Code modified to consider the Positon of bend instead of leave
position.

Outfitting:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 331 of 517
Product Release Letter
Incident Issue Description
Number Number
59418 103711 Title: Isodraft - ISO hyperplant on OPTION
Symptoms: Weld Number missing when ISO hyperplant option set to 'ON'
Previous/Known workaround: None
Solution: Take account of different comment types all pointing to a weld.
66298 125892 Title: Design - Add pick from DBlisting is actually remove pick
Symptoms: Could not add to list by picking.
Previous/Known workaround: Have to navigate and add CE.
Solution: Fixed.
66337 130227 Title: HVAC - Modify HVAC always reset the Material and Material Thickness.
Symptoms: Change MATL property and GAUG property.
Previous/Known workaround: Not satisfactory.
Solution: A new option on HVAC Settings menu controls whether Spec material
is reset or existing material is retained.
73358 149960 Title: Isodraft - User Defined SKEY with 5 connections not using all connections
Symptoms: User Defined SKEY with 5 connections not using all connections.
Previous/Known workaround: None
Solution: Handle any components with 3 tee points on the same side correctly.
74248, 152368, Title: Isodraft - Bolts missing when Flanges in different Branches of same Pipe
74970 153856 Symptoms: Bolts missing from isometric
Previous/Known workaround: Move Flanges into same Branch.
Solution: Calculate bolting requirements when matching Flanges are in
different Branches of the same Pipe.
75813 157076 Title: HVAC Grid/Tile Utility appeared not to work
Symptoms: No grid displayed but elements exist in database.
Previous/Known workaround: REM CE ADD CE.
Solution: Fixed.
76039 157727 Title: Graphic performance improvements
Symptoms: The general manipulations for 3D canvas as Zooming, Panning
and Rotating are slow
Previous/Known workaround: Limit the number of elements in graphical view
Solution: New version of graphical library with better performance

Configuration of both GPU performance and choice of renderer


(DirectX/OpenGL) is be controlled via evars.

The defaults can be overwritten by setting following environment variables

Switching between DirectX\OpenGL(default DX)


- AVEVA_GRAPHICS_XP_COMPATIBLE=1 (to switch off DX support)
Amount of graphical memory used:
- AVEVA_GPU_ENABLE_CACHE=0 (to disable GPU caching entirely)
- AVEVA_GPU_CACHE_SIZE_PERCENT=<some value in %>
76209 158620 Title: HVAC - Negative DESPs in the HVAC component
Symptoms: Rectangular Material Connection (FLEX) gave negative surface
area.
Previous/Known workaround: Manual correction.
Solution: MSURFACE now has a special case PML.
76535, 159446, Title: Isodraft - Bolts duplicated when matching Flanges in different Pipes
76706 159664 Symptoms: Bolts shown on both isometrics.
Previous/Known workaround: None
Solution: Show bolts on downstream pipe.
77423 162444 Title: Export spool objects in rvm file
Symptoms: Currently not possible.
Previous/Known workaround: None
Solution: Enhance export code to navigate spool hierarchy.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 332 of 517
Product Release Letter
Incident Issue Description
Number Number
66875 164324 Title: Pick up 2D view projection from 3D view in Marine Drafting.
Symptoms: Considered to be an enhancement to the view definition workflow
using the 3D View.
Previous workaround: N/A
Solution: A new toggle button 'Direction' has been added to the 3D View
window. This is set to OFF by default. When selected the update & refresh
method takes the current 3D view direction and elevation, converts it into an
equivalent Draft View direction format and applies it to the 2D view before the
update design is executed.: Please also refer to section Enhancements at the
beginning of this document.
78326 164335 Title: Isodraft - Bolts missing when Branch tail connected to Nozzle
Symptoms: Bolts missing at Nozzle.
Previous/Known workaround: None
Solution: Calculate bolting requirement at Nozzle.
79752 169318 Title: Isodraft - Delimiter for PSPOOL Name extraction
Symptoms: Only full PSPOOL name can be shown on isometric.
Previous/Known workaround: None
Solution: New PSPOOL command. For mor information please also refer to
section Enhancements at the beginning of this document.
79753 169320 Title: Isodraft - Removal of coupling penetrations on iso when support is set to
OFF
Symptoms: Removal of coupling penetrations on iso when support is set to
OFF.
Previous/Known workaround: None
Solution: Do not treat coupling penetrations like supports.
79797 169357 Title: Isodraft - Penetration coupling located at the end of the branch is missing
its symbol in isometric
Symptoms: Penetration coupling located at the end of the branch is missing its
symbol in isometric.
Previous/Known workaround: None
Solution: Do not treat coupling penetrations like supports.
80108 171185 Title: An error in the handling of some arcs which could cause discrepancies
between wireline and hidden-line view types
Symptoms: Observed differences in the display of some nearly-semicircular
arcs in drawings when wireline view types were compared with other view types.
Previous/Known workaround: None
Solution: Core code has been corrected.
80415 171684 Title: HVAC - Placing a HACC fitting removes the upstream implied ducting
Symptoms: Implied tube disappears when data consistency requirement is not
met.
Previous/Known workaround: Test duct size values. (Make sure cata
definition correct).
Solution: If Duct size is unset, it is set by PML same as previous.
81292 173132 Title: Draft - Revision control form not working
Symptoms: Syntax error when invoking new revision.
Previous/Known workaround: None
Solution: Fixed code issue within revision control form.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 333 of 517
Product Release Letter

12.1.SP4.24

Marine Drafting:

Incident Issue Description


Number Number
166679 Title: COMPATIBILITY: PICGRS error - When saving a drawing in Marine
Drafting or in Outfitting Draft
Symptoms: It was not possible to do savework in 12.1.SP4 on a database which
contained attribute types created in E3D2.
Previous/Known workaround: Use savework in E3D2.
Solution: Restrictions in savework in 12.1.SP4 have been relaxed so it is now
possible to do a savework on a database containing attribute types introduced at
E3D2. However, the restriction still exists for extract operations such as flush and
refresh. The user should therefore use E3D2 to do flush and refresh operations
on an extract hierarchy containing attribute types introduced at E3D2.

Engineering:

Incident Issue Description


Number Number
76063 157762 Title: Datasheet Export convert Text in a Real
Symptoms: Datasheet which has numeric value while exporting to Excel, Value
in the exported excel is incorrect.
Previous/Known workaround: Exported data should be independent of the
machine culture.
Solution: Made changes so that the values in the exported Excel display
according to the culture of the machine on which the application is running.

Pipe Fabrication:

Inciden Issue Description


t Number
Number
76444 158787 Title: Make Pipe Fabrication and Isodraft consistent with regard to the SHOP,
LOFF and SKEY attributes of a Coupling.
Symptoms: Pipe Fabrication automatically creates separate spools when shop =
false for offline components
Previous/Known workaround: No known workaround.
Solution: As per proposed solution – please see the Support Notes.

Mechanical Equipment Interface:

Incident Defect Description


Number Number
81301 173158 Title: Adding SITE to 3D view raises fatal error ( Attempted to read or write
protected memory )
Symptoms: When adding a large volume imported via MEI, the system aborts.
Previous/Known workaround: No known workaround exists.
Solution: The program uses too much virtual memory and crashes when the
memory usage reaches ~3.6 GB. The memory usage has been greatly reduced
by removing a memory leak that was introduced in 12.1.SP4 Fix.22.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 334 of 517
Product Release Letter

Outfitting:

Inciden Issue Description


t Number
Number
51728 86166 Title: Model Editor - appl. crashes when orientate handle to the current handle
origin.
Symptoms: Application crash.
Known workaround: No known workaround.
Solution: The application no longer crashes when the user tries to move the
Model Editor handles to the current handle origin.
64664, 120406, Title: Isodraft - GPART UDA cannot be used for Itemcode if referenced from
73762 151133 SPCO.
Symptoms: UDA value not shown in Material List Itemcode column.
Previous/Known workaround: No known workaround.
Solution: Use GPART UDA if referenced from SPCO.
77057 161206 Title: Isodraft - Tube part number does not change after weld without leave tube
Symptoms: Incorrect tube part numbers on isometric.
Previous/Known workaround: Move weld to create leave tube.
Solution: Change tube part number after Weld without leave tube.
77556 161814 Title: Draft - SLABs with circular frames did not have circular wipeouts craeted
Symptoms: Blanking missing on son SYMB when exported
Previous/Known workaround: N/A
Solution: Code to generate circular wipeouts now executed.
77809 162626 Title: Draft - Backing sheet gets incorrect frame size.
Symptoms: A frame line is drawn on a sheet that is the wrong size for the sheet.
Previous/Known workaround: Use UPDATE PIC on the overlay used by the
sheet (not guaranteed).
Solution: Handle failure to read absent picture files in the correct way.
77991 163401 Title: Draft - Symbols are not exporting when nested.
Symptoms: Nested symbols are exported to dxf/dwg incorrectly or not at all.
Previous/Known workaround: Keep template names < 31 chars in length.
Solution: Improved the way long names get shortened.
166679 Title: Draft and Marine Drafting - COMPATIBILITY: PICGRS error - When saving
a drawing in Marine Drafting or in Outfitting Draft
Symptoms: It was not possible to do savework in 12.1.SP4 on a database which
contained attribute types created in E3D2.
Previous/Known workaround: Use savework in E3D2.
Solution: Restrictions in savework in 12.1.SP4 have been relaxed so it is now
possible to do a savework on a database containing attribute types introduced at
E3D2. However, the restriction still exists for extract operations such as flush and
refresh. The user should therefore use E3D2 to do flush and refresh operations
on an extract hierarchy containing attribute types introduced at E3D2.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 335 of 517
Product Release Letter
12.1.SP4.23

Planar Hull:

Incident Issue Description


Number Number
69664 139054 Title: Duplicate component creation
Symptoms: By mistake the user double click on the Create button in the
Statement Wizard which then creates a duplicated component. This duplicate is
not visible for the user and will produce the wrong final result in the part.
Previous/Known workaround: Manually check the Planar Panel for duplicated
statements.
Solution: A warning will be presented to the user if the user repeatedly click on
the Create button without changing any values.
79353 167970 Title: Bevel Text changed for pillar end.
Symptoms: The system does not create a correct statement for Bevel at Pillar
ends. It set a comma between the web and flange bevels instead of a colon.
Previous/Known workaround: Manually change the statement to the correct
delimiter.
Solution: Fixed so the system will generate a correct statement.
80426 171335 Title: SB_SHIPSCH directory can not be recognized on SchemeInput
Symptoms: when using function "Input Schema", the expected directory
assigned to SB_SHIPSCH is not listed.
Previous/Known workaround: Manualy navigate to the correct directory.
Solution: Fixed so the directory given by SB_SHIPSCH is listed when the user is
prompted to select the input schema.

Curved Hull:

Incident Issue Description


Number Number
76010 157722 Title: Curved Panel "Dimensioning" function
Symptoms: During use of the "Hull Tools -> Dimensioning" function, the user is
prompted to choose "PS" or "SB" for each step of measurement definition.
Previous/Known workaround: No known workaround exists.
Solution: The function is changed so the application will find out which selected
instance that is indicated.
164488 Title: Slow performance of shell expansion view generation.
Symptoms: Creating a shell expansion view takes a long time.
Previous/Known workaround: No known workaround.
Solution: The performance has been improved.

Hull Production:

Incident Issue Description


Number Number
77191 161056 Title: Curved Modelling output Bend Template incorrect.
Symptoms: Wrong excess value printed in the drawing.
Previous/Known workaround: No known workaround exists.
Solution: Correct excess values will be presented in the Bend Template
Drawing.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 336 of 517
Product Release Letter
Incident Issue Description
Number Number
78361 164430 Title: Stiffener Sketches - Shell Profile holes on SB shown upside down.
Symptoms: For a Starboard shell profile – holes in stiffeners are OK in the
model, but at stiffener sketches– they are shown upside-down. This applies to all
holes, which geometry is unsymmetrical with respect to the axis parallel to
stiffener trace.
Previous/Known workaround: No known workaround exists.
Solution: Profile sketch for shell stiffeners with holes are corrected.
79237 167783 Title: Weight information of specific profiles having end cut snip is wrong
Symptoms: Weight calculation for pillars is not considering sniped endcuts for
some profile types.
Previous/Known workaround: No known workaround exists.
Solution: WCOG calculation modified so that endcuts will be considered for
pillars with profile type 50 thru 55 and 59.
80349 171189 Title: TbGeneric2Plate.exe does not work on 12.1.SP4.22
Symptoms: It is not possible to create plates in MANU from a generic file.
Previous/Known workaround: No workaround exists.
Solution: The code has been corrected.
80351 171193 Title: Dimensions text of MPROF for flatbar is wrong
Symptoms: Thickness missing in dimensions text for flatbars, bulb bars, half-
round bars and tubes.
Previous/Known workaround: No known workaround exists.
Solution: Unpacking of profile parameters corrected.

Hull Nesting:

Incident Issue Description


Number Number
76560 159050 Title: Batch Autonest - Mirror nesting
Symptoms: Not possible to nest mirror nesting in batch autonest.
Previous/Known workaround: No known workaround exists.
Solution: The nesting will be made is the same way as when you create a parts
menu for mirrored nests. Only the portside parts from symmetrical panels will be
nested but the starboard parts will automatically be marked as nested when the
nest is stored.

Marine Drafting:

Incident Issue Description


Number Number
66715, 127101, Title: Level 3 subpicture for implied PIPE and HVAC components
62941 114735 Symptoms: The geometry of implied "TUBIs" are stored in the same level 3
subpicture as the component it is attached to.
Previous/Known workaround: No known workaround
Solution: It is now possible to get the "tubes" both for pipe and hvac in a
separate level 3 subpicture. There is a new drafting default keyword
"MODEL_COMPONENT_FOR_IMPLIED_MODEL" that you should set the
"Separate" (default value is "Combined"). After that you need to do "update
design" on existing views. In the Drafting explorer you can now see separate level
3 subpictures for the tubes with the name as "ILEAVE TUBI OF <gid>".
If you right click on a tube is the canvas and select "Navigate in Design Explorer"
this will navigate to the TUB element (provided that you have the option to see
them activated).

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 337 of 517
Product Release Letter
Incident Issue Description
Number Number
75932 157501 Title: "Update All" will mess up annotations (texts, dimensions, labels) for hull
symbolic views.
Symptoms: The annotation geometry seems to be duplicated and in the wrong
position.
Previous/Known workaround: Do not use "update all", use "update design" and
"update anno".
Solution: Update all should now behave normally.
76044 157729 Title: SaveAs drawing, performance.
Symptoms: The performance of the function Save As... needs to improve.
Previous/Known workaround: No known workaround.
Solution: The performance in Save As function has been improved.
The performance problem with "Save As" highly depends on the number of
PADD Views contained in the drawing. A way for the user to speed up
performance is to Purge the drawing (to get rid of empty PADD Views) before
saving it. For this purpose, the default variable PURGE_EMPTY_VIEW should be
set to "Padd".
Along with this solution comes also a significant performance improvement in the
Purge function.
164869 Title: Performance of zoom and pan in drafting
Symptoms: Zooming and panning in drafting is slow
Previous/Known workaround: None
Solution: The performance of zoom and pan has been improved. Furthermore a
new way of simplified drawing during zoom and pan has been implemented. This
functionality is obtained by holding down the "Ctrl" key while zooming and/or
panning. The system will then only draw each component in the drawing as
its circumscribed box. When the "Ctrl" key is released, the system will revert back
to normal draw mode.
79455 168289 Title: Error retrieving SVAssemblies attribute for HSVDEF element.
Symptoms: When symbolic view is queried the SVAssemblies attritute retrieves
the FullName of the assemblies.
If this name has a length greater of 26 characters the attribute is shown as unset.
Previous/Known workaround: No known workaround exists
Solution: Corrected so longer names will be presented for the attribute.

Engineering:

Incident Issue Description


Number Number
56600 95256 Title: Advanced config in Compare/Update doesn't work well with array of
reference
Symptoms: Rules using array references like NAMN OF SCPLINE OF SCIREF
numb 0 OF SOURCE do not return correct results
Known workaround: N/A
Solution: Rules with array references are handled correctly.
56608 95286 Title: Issue on Compare Update with advanced rule, query through attribute with
type : array of reference
Symptoms: Rules using array references like Desc of SCLOREF num 0 of
source do not return correct results
Known workaround: N/A
Solution: Rules with array references are handled correctly.

Schematic 3D Integrator:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 338 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
165344 Title: Comparing all Pipes on PID one by one gives a different result than
comparing the complete PID.
Symptoms: Comparing 3 pipes together gives different results to individually.
Previous/Known workaround: Compare individually.
Solution: Extra validation for comparison scope across branch connections.

Pipe Fabrication:

Inciden Issue Description


t Number
Number
74106 152078 Title: Cannot Create Weld on Set-On Tee or OLET
Symptoms: Cannot Create Weld on Set-On Tee or OLET which has not valid P3
connection reference.
Previous/Known workaround: No known workaround.
Solution: The program modified to create a weld for set-on tee or olet which has
not valid p3 connection reference.

Mechanical Equipment Interface:

Incident Defect Description


Number Number
78363 164433 Title: Erroneous holes prevent STEP export.
Symptoms: Not possible to export to a STEP file when the planar panel contains
identical holes.
Previous/Known workaround: Check the planar panel for identical holes before
exporting the panel.
Solution: The geometry engine is not able to process input curves like multiple
holes to create the proper geometry that is exported to the STEP file. Some
changes have been made that allow in those cases to fall back on the creation
and export of a facetted model instead.

Outfitting:

Inciden Issue Description


t Number
Number
50034 79613 Error when deleting members of a new element type defined by a UDET
78706 165591 Title: Isodraft - Express Bend Radius in multiples of the Outside Diameter
Symptoms: The Bend Radius can only be expressed in multiples of the Nominal
Bore.
Previous/Known workaround: None
Solution: New option BENDRADIUS OUTDIAM.
78743 166303 Title: Isometrics - PSPOOL isometric does not show both branches for an OLET
or TEE connection.
Symptoms: Only off leg branch is shown on PSPOOL isometric.
Previous/Known workaround: No known workaround.
Solution: Start at first PSARFA branch of PSPOOL.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 339 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
166976 Title: Backport Compare/Update functionality from Engineering 14.1.SP1 to
PDMS 12.1.SP4
Symptoms: Need alignment of capabilities for integrated project (Engineering,
Diagrams, E3D, PDMS)
Previous/Known workaround: N/A
Solution: Backport all capabilities of Compare/Update.
68193 167409 Title: PDMS Export: Type of RNODE have a wrong position as 0.0.0
Symptoms: Exported RNODES at the origin
Previous/Known workaround: No known workaround.
Solution: This has now been resolved.

12.1.SP4.22

Assembly Planning:

Incident Issue Description


Number Number
68811 137636 Title: Assembly Planning, Some Pipe Spool elements do not get collected
correctly
Symptoms: Some elements at the spool breaks are not collected
(marked/coloured) correctly.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so all spool elements are correctly marked.

Initial Design:

Incident Issue Description


Number Number
36519 63367 Title: Loading/Discharging errors when deleting stages
Symptoms: Unexpected behaviour of dialog when deleting stages
Previous/Known workaround: No known workaround.
Solution: Corrected the grid component to proper behaviour when deleting rows
(stages).
36518 63368 Title: When starting interactive loading dialog from loading diagram it was not
populated with indicated compartment info
Symptoms: Dialog did not contain any data
Previous/Known workaround: Perform a left mouse click on compartment in
loading diagram after interactive loading dialog have been invoked.
Solution: Detection of indicated compartment when right clicking for pop-up
menu in loading diagram is implemented.
4456 68499 Title: Apply button activated in interactive loading form also for changes to name
and category fields
Symptoms: Changes to name and category fields does not activate Apply button
Previous/Known workaround: Edit name and category in tank plan node
Solution: The dialog behaviour have been changed to activate apply button on
changes to name and category fields.
Further the FSM value edit box is only active when the content makes a
difference to the calculations, FSM type is fixed. Minor glitch that were detected
while investigating the other issue.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 340 of 517
Product Release Letter
Incident Issue Description
Number Number
135240 Title: Units incorrect when compartments are stored in design databases from
Surface & Compartment
Symptoms: LCG,TCG, VCG and volumes are listed with incorrect units in design
applications
Previous/Known workaround: None
Solution: Implementation in Surface & Compartment changed to correct units.
69204 137823 Title: Crash in DPDAS file import corrected
Symptoms: Application crash on importing DPDAS file.
Previous/Known workaround: None
Solution: Code have been corrected to avoid error.
71427 144596 Title: Hydrodynamics Sea Keeping Long Term Calculation
Symptoms: In Hydrostatics&Hydrodynamics Applıcation , when calculating Sea
Keeping for Long Term , system does not take Bending Moment and shear Force
values which ıs given as crıteria for calculating See Keepıng Index.
Previous/Known workaround: No known workaround exists.
Solution: The calculation has been corrected.
72800 148681 Title: Improved BV1033 output for GZ-graph and table
Symptoms: Incorrect and missing or too detailed information shown in GZ- graph
and table
Previous workaround: No known workaround.
Solution: Corrected the calculation of frees surface heeling arm and added extra
columns in table for combined total of heeling arms for BV1033 (wind, turn, free
surface) and changed individual curves in graph to only displaying the combined
total curve.
74076 151918 Title: Lightweight centres reported without axis definition
Symptoms: When switching the direction of an axis the output remains the same
Previous/Known workaround: No known workaround.
Solution: The formatting instruction of the lightweight centres have been
switched from not including information of axis to the correct one specifying the
axes and thus applying the correct axis direction before printing the value.
73924 153689 Title: Symmetry can be set on surfaces released from Surface & Compartment
Symptoms: Surface & Compartment does not handle symmetry and for
symmetric surfaces to be released to hull design the Surface Manager application
must be used.
Previous/Known workaround: Use Surface Manager for releasing symmetric
surfaces.
Solution: Addition of an extra dialog with a question for surfaces defined
completely on either side of y=0, if they are to be released as symmetric or not.
76346 158758 Title: Increased decimals from 1 to 3 in Trim/List correction table
Symptoms: Only one decimal in Trim/List correction table
Known workaround: None, decimal value hard coded
Solution: Changed the hard coded value for number of decimals in the Trim/List
correction table from 1 to 3.

Planar Hull:

Incident Issue Description


Number Number
35479, 69246, Title: Boundary wizard Profile Crossection, Surface missing
41666 69609 Symptoms: When using the Crossection for Shell Profiles in the Boundary
Wizard the surface is not added to the statement if the Shell Profile belongs to a
sub-surface.
Previous/Known workaround: Add manually SHP='<profile name>' in the
statement.
Solution: Corrected so the wizard will handle sub-surfaces.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 341 of 517
Product Release Letter
Incident Issue Description
Number Number
36938 69321 Title: Bracket Panel Move with 'FR' and 'LP' prefixes do not work.
Symptoms: Entering a FR or LP term in the Bracket Panel "Move" field does not
move the bracket.
Previous/Known workaround: This field is a distance and not a position so
FR/LP is not valid. Use a real value as distance.
Solution: Non numeric input will give an error.
57442 96950 Title: Bracket Stiffener Material Quality
Symptoms: The grade of the stiffening on a standard bracket is always the same
as for the bracket plate itself. There is no way to have a different quality defined
for the stiffeners.
Previous/Known workaround: workaround is to define the brackets as Bracket
Panels where the stiffeners are generated separately.
Solution: A new keyword, PQUAL, has been introduced to the bracket
statement. If given, all stiffeners will get the quality defined by the PQUAL
keyword.
If not given, the quality for the stiffeners will be fetched from the bracket plate.
54734 97644 Title: Panel Bracket System Name Error
Symptoms: Brackets on Knuckled Panels, defined on different sub-panels gets
conflicting names in the Design Explorer.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the brackets gets unique names
in the design explorer.
60030 105156 Title: Panels referring to complex RSOs are not visible as trace line in section
views.
Symptoms: There is a gap in the symbolic view for a SP panel referring a RSO.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that there will be no gap in the
section view.
67208 134511 Title: Plate arrangement change caused by boundary change with fixed seam
definition
Symptoms: If changing the boundary order, the plates are shifted even though
the seam is defined at a fixed position.
Previous/Known workaround: No known workaround exists.
Solution: The solution for updating plates after modification to the boundary or
the seams has been improved. If exactly one of the existing plate points is inside
any of the resulting plate areas that plate is matched with that area.
67210 134515 Title: Deletion of seams due to shifting seams or changing boundary sequence
(referenced seams)
Symptoms: Seams related to boundaries are often missed to update when
boundaries are changed.
Previous/Known workaround: Manually go through all seams in the panel when
a boundary is modified.
Solution: A warning is given when a seam is deleted due to boundary changes.
69778 139474 Title: Improvement Update of panel intersect symbols.
Symptoms: Panel intersecting symbols (Tools->Model->Panel intersect) is not
updated at View Create.
Previous/Known workaround: No known workaround exists.
Solution: The handling of intersection symbols has been improved so that they
are updated on recreate view.
69679 145371 Title: Default to control clip symbols in symbolic view.
Symptoms: The placement of clip symbols in intersecting symbolic views have
been controlled by default value MAT_SYMB_SIZE.
Previous/Known workaround: No known workaround.
Solution: Two new default values have been added:
CLIP_SYMB_DIST - The distance from the plate edge to the symbol. Default 2.5
mm CLIP_SYMB_SIZE - The symbol size. Default 5 mm.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 342 of 517
Product Release Letter
Incident Issue Description
Number Number
71678, 145418, Title: Verify Model function is not completed successfully.
77216 160906 Symptoms: The function seems not to come to an end.
Previous/Known workaround: No known workaround exists.
Solution: The function is mostly finished but not all text was always written in the
log file. This is now corrected.
73725 151079 Title: Interpolation point has applying invalid default.
Symptoms: In the Statement Wizard, if no factor is given for an interpolation
point, the system will default it to 0.5 (F=0.5) even when factor of zero is desired.
Previous/Known workaround: Manually change the factor in the panel schema.
Solution: The default factor will be set to zero if no factor is given.
74249 152295 Title: Problem to incorrectly display the hole of curved stiffener in 3D View
Symptoms: The hole in a Planar Panel Curved Stiffener is displayed at the
wrong location in the 3D view. It is correct in Model View and symbolic View.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the hole are positioned correct
on the curved stiffener.
74886, 153462, Title: AutoPosno for Knuckled panel crashed with brackets
76850 160346 Symptoms: AutoPos aborts in some cases when a Knuckled Panel is included
and the panel has Brackets.
Previous/Known workaround: No known workaround exists.
Solution: Corrects so AutoPos will handle Brackets on Knuckled Panels.
74958 154238 Title: Error on creation of Bracket (type BC) syntax 1, in SB panel defined by 3
point
Symptoms: Bracket on a SB panel, referring to internal tagged stiffeners fails to
identify the stiffeners. It works fine on a PS panel.
Known workaround: No known workaround exists.
Solution: Fixed so the brackets on the SB panel can be created in the same way
as for the PS panel.
76122 157888 Title: Enhancement Request for Selected corner to Notch.
Symptoms: In Statement Wizard, when indicating a corner when defining corner
notches, the indicated corner is highlighted by a point. This is difficult to see.
Previous/Known workaround: No known workaround exists.
Solution: The point indication is changed to circle which is more easy to see.
77699 162296 Title: NUM value is not taken care at component creation
Symptoms: When using an already defined NUM in a following NUM, the value
is not handled correctly.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the NUM value is using already defined NUM values too.

Curved Hull:

Incident Issue Description


Number Number
13215 68556 Title: Shell plate definition error in bow area
Symptoms: When creating a shell plate in the bow area that is a CL plate, no
plate is created.
Previous/Known workaround: No known workaround exists
Solution: The problem has been solved so that shell plates over CL can be
created also in the bow area.
52785 87139 Title: Dialog selection does not appear in the SB Curved Panel View.
Symptoms: In a Curved Panel Symbolic View, the information about Planar
Panels and Shell Curves are missing for a starboard Curved Panel.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the Planar Panels and Shell curves will also be included
in SB side Curved Panel symbolic view.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 343 of 517
Product Release Letter
Incident Issue Description
Number Number
71595 145299 Title: Partname for S-side plate.
Symptoms: In all output the system loose position number from shell plates valid
for S-side on a CL shell panel.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the programs put correct position
number. The shell stiffener has to be recreated with the new solution.
72006 146746 Title: Verify Curved Model.
Symptoms: Running MarHullVerify fails as it does not find the file
MarHullVeify.xsd.
Previous/Known workaround: Start the job with the "-ns" qualifier.
Solution: The missing file MarHullVerify.xsd will be included in the installation.
73063 149558 Title: Holes in Curved Panels
Symptoms: The handling of holes in curved panel over / in CL (SP) do not work
correctly
Previous workaround: No known workaround exists.
Solution: Corrected so holes are treated as expected in a CL panel.
73588 150700 Title: ALL when overriding objects
Symptoms: Selection ALL is not possible when creating already existing curves
with function "Hull Tools/Curve/Create Curve"
Previous workaround: Use the Curved Hull tool to create curved.
Solution: The problem has been solved so that ALL now works also in this
function.
76011 157723 Title: Curved Panel "Dimensioning" function
Symptoms: When making a dimensioning with the curved Panel Dimensioning
tool, some of the dimensions are upside down.
Previous/Known workaround: Manual move the incorrect measure strings.
Solution: The problem has been solved so that the dimensions are not mirrored
depending on the direction of the measurement.
76367 158850 Title: In ShelI Expansion view holes are missing in Stbd
Symptoms: When generating the Shell Expansion view for curve panel, holes in
Stbd are missing where as it is coming in port side.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that the SB specific holes also
are put in the Shell Expansion view.
76607 159192 Title: Over C/L shell profile split fails on SB-side.
Symptoms: Over C/L shell profiles can be split to shell stiffener by Planar panel,
but results in wrong split if split is made on SB side. On PS it is ok.
Previous/Known workaround: No known workaround exists.
Solution: The problem has been solved so that it is possible to split an Over CL
shell profile on SB side.

Hull Structural Design:

Incident Issue Description


Number Number
37871 66576 Title: Creation of midship surface requires suffix but later it is ignored.
Symptoms: User is forced to enter a surface suffix when creating midhsip
surface.
Previous/Known workaround: Enter a suffix even if it is not used later.
Solution: The check for empty suffix when OK is pressed in the dialog have been
removed and surface is created without suffix.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 344 of 517
Product Release Letter
Incident Issue Description
Number Number
55344, 94004, Title: Multi faces RSO used as delimiter in Panel or RSO became wrong after
71557 145326 modification
Symptoms: The face of multifaces RSO used as boundary of another RSO or a
Panel became wrong after modification of the delimiting RSO because the face
number change
Previous/Known workaround: Manually check and change the face number in
the boundary statement.
Solution: A "point" (actually a ray) in global coordinates is added at the middle of
the boundary limit if defined by RSO face number and the panel is located by the
same RSO. For existing panels the point is added automatically when
regenerated and stored. As for the panel statement the face number is kept as
information and is also updated if necessary.
58528 100502 Title: Difficult to edit Complex RSOs which are imported from Surface and
Compartment Module
Symptoms: -----
Known workaround: -----
Solution: Structural Design now triangulate faces where needed, in case not
made planar beforehand.
Make planar, previously automatic, is now selected by the user. Furthermore, the
make planar routine is only making planar in line with the intentions given by the
point in the next row of the definition. If this is not possible, no planar face is
made and triangulation will take care of the non-planar face.
72602, 148030, Title: RSO / Edit Shape
58528, 100502, Symptoms: Looks alike the system forces faces to rectangle planes which
75781 156930 cause, that the object do not follow given input.
Previous/Known workaround: No known workaround exists.
Solution: Structural Design now triangulate faces where needed, in case not
made planar beforehand. Make planar, previously automatic, is now selected by
the user. Furthermore, the make planar routine is only making planar in line with
the intentions given by the point in the next row of the definition. If this is not
possible, no planar face is made and triangulation will take care of the non-planar
face.
59560 104230 Title: Connection between Design / Production Panels.
Previous/Known workaround: No known workaround.
Solution: A utility program sj912 is created that can list and to some extent
modify references between design and production panels. It can also list and set
requests.
65216 122037 Title: Hull Structural Design crashes during block division
Symptoms: Block division stops (crash) with the error message "WA204 ERROR:
201 PROCEDURE: 1007"
Previous/Known workaround: No known workaround exists.
Solution: This is an error when the system tries to create the default production
block. The error is corrected.
65261 122144 Title: Block division fails when block seam is defined in RSO cutting plane
Symptoms: If the cutter coincides with an already defined block seam, the Block
division process stops and never sorts in the production panels in the blocks.
Previous/Known workaround: Make sure there is no existing blockseam at the
same plane as the cutter plane.
Solution: If the block seam to add coincides with an existing seam, this seam is
removed.
71673, 145392, Title: FE Modeller has some stability issues.
73467, 150230, Symptoms: FE modeller sometimes crashes or halts without any immediate
72140 146697 reason to follow up.
Previous/Known workaround: No known workaround exists.
Solution: Various errors have been found and fixed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 345 of 517
Product Release Letter
Incident Issue Description
Number Number
71715 145551 Title: FE model Output values for nodes.
Symptoms: In FE model, The output nodes coordinates seems in need of
rounding up due to high sensitivity of GeniE program.
Previous/Known workaround: No known workaround exists.
Solution: The exported coordinates are now rounded to the nearest mm.
71885 146077 Title: Blocks not correctly created
Symptoms: When creating a block in Structural design as symmetrical, the
reflected block is not created in the same database but in random db with R/W
access.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the reflected block is created in the correct data base.
71864 146791 Title: Shape of Beam Property in exported bdf-file.
Symptoms: Shapes of all beam properties are Rectangular bar in exported bdf-
file
Previous/Known workaround: No known workaround exists.
Solution: In the Nastran BDF export an option has been added that enables to
user to select if beams should be defined by their dimensions (PBEAML) or by
their integrated characteristics (PBEAM).
72497 147637 Title: Unknown error message with Idealization
Symptoms: When executing a block for Idealization via Structural Design, the
following error message occur:
- "Panel xxx_B6-FR94-51 NOT activated" on the Prompt
- "Object currently locked by another user" on the Message window
Adminshows no ghost user.
Previous/Known workaround: No known workaround exists.
Solution: Some error handling has been added so that the idealisation can
proceed after skipping erroneous panels.
72557 147829 Title: FE Model Crash in 12.1.SP4.17[build 5702] but fine in 12.1.SP4.15
Symptoms: No problem with the FE Model in 12.1.SP4.15 but in 12.1.SP4.17
the system aborts.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the system will not abort.
73522 150408 Title: Split shell stiffeners via RSO doesn´t consider thickness of panel
Symptoms: If trying to split a Shell Profile against a RSO that contains Planar
Panel, the thickness of the panels are not taken into considerations.
Previous workaround: Split the Shell Profile against Planar Panel if possible.
Solution: The shell profiles are now split with scantling compensation in all cases
when referring an RSO.
73901 151406 Title: FE export format of MNF for Maestro (enhancement)
Symptoms: It will be appreciated if we have an export format of MNF from FEA
vendor MAESTRO
Previous/Known workaround: No known workaround.
Solution: An option has been implemented to export FE models as MNF files
and import them in the FEA software MAESTRO.
74344 152424 Title: FEM - optional calculation of beam properties around neutral axis instead
of stiffener trace line
Symptoms: -----
Previous/Known workaround: No known workaround.
Solution: An option has been added that enables the user to choose if beam
properties shall be calculated around the neutral axis (offset beams) or around
the stiffener trace line considering also the effective width of the connected plate
(hybrid beams).

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 346 of 517
Product Release Letter
Incident Issue Description
Number Number
75374 156516 Title: RSO not visible in symbolic view
Symptoms: Sometimes the system is not showing all RSO-objects in symbolic
views.
Previous/Known workaround: No known workaround exists
Solution: The RSO box is not correctly updated when the RSO plane is changed
via the RSO/Edit Shape function. This will then make the Symbolic View to miss
the RSO.
77697 162309 Title: Path length for the SBH_KNUCKLE_CTRL file
Symptoms: The check of SBH_KNUCKLE_CTRL file with INITHULL fails even if
the system is capable to open the file with INITHULL / EDIT command.
Previous/Known workaround: The limit is 80 characters for the path length.
Make sure the total length (path + filename) does not exceed this limit.
Solution: The length of path + filename is increased to 255 characters.

Hull Production:

Incident Issue Description


Number Number
59712 104462 Title: GSD Setting In PLCM
Symptoms: not possible to simply define GSD for just PLCM and not for other
parts.
Previous/Known workaround: Modify the d065-file before running ppanparts for
PLCM.
Solution: A new keyword has been added to ppanparts.ip. GSD,<filename,
where <filename> should point to the file containing the GSD definitions.
50767 107281 Title: Curved Panel which symmetry is SB only has problem in its ATX file
Symptoms: For a Starboard Curved Panel, the robot file (ATX) also includes
Port side specific data such as portside specific shell profiles.
Previous Workaround: No known workaround exists.
Solution: Corrected so the ATX file will only contain data from correct side.
63785 119207 Title: Templates marking line can’t be created correctly.
Symptoms: Templates are wrong when several plates are given as input.
Previous/Known workaround: Give only one plate as input.
Solution: Corrected so templates are created correctly also when more than one
plate is given as input.
69979 142660 Title: PLCM: REF-Lines don’t appear as Markings in Gen-Files
Symptoms: Reference lines are activated and marking starts are given for them.
After verify the marking information should appear in genfile but they are missing.
Previous/Known workaround: No known workaround exists.
Solution: The error has been corrected. The reference lines need to be re-
defined in existing nests.
70986 142853 Title: Rest plate stored as mogobj.
Symptoms: The restplates from Nesting appears MOGOBJs in the MOGWLD
and not as MRPLA in MRESTQ as expected.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so restplates will end up in the correct place in the MANU
data base.
70985, 142941, Title: Interline space in Hull Pos No.
73637 150872 Symptoms: The distance between the dimension string and the quality string in
the Hull Position number note is too big.
Previous/Known workaround: No known workaround exists.
Solution: The spacing between the dimension and the quality is corrected to be
one space.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 347 of 517
Product Release Letter
Incident Issue Description
Number Number
71169 145357 Title: Invalid Bending Template and Table information
Symptoms: Missing template and the message that the attachment angle is out
of bounds.
Previous/Known workaround: No known workaround exists.
Solution: Correction has been made, moving template plane inside the shell
plate.
71702 145492 Title: Problem of Bending Template
Symptoms: Cutouts in templates over CL are missing.
Previous/Known workaround: No known workaround exists.
Solution: Cutouts are added for bending templates over CL.
73995 151618 Title: Limit value of NGROUPS in na_ctrl.ip
Symptoms: Adding more than 200 groups in na_ctrl file has no affect.
Previous/Known workaround: No known workaround.
Solution: The limits of profile groups in the na_ctrl.ip file has been extended from
200 to 1000 groups.
75833 157130 Title: 3- Axis nesting Crash
Symptoms: 3- Axis nesting Crash.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the 3-axis nest should not abort.
76178 158035 Title: When run Bending Template, the system crash down (Fatal Error).
Symptoms: The Bending Template application crash for a three side plate.
Previous/Known workaround: No known workaround exists.
Solution: Correction has been made for the crash in bending template
application.
76179 158036 Title: When run bending Template, It failed to calculate base plane.
Symptoms: When run bending Template, It failed to calculate base plane.
Message in log file is:
Cutting plane too close to CL moved toward SB
Failed to calculate base plane
Only one frame position is intersecting the curved plate, change settings or
change template type.
Known workaround: No known workaround exists.
Solution: Correction of base plane calculation has been made.
76320 158583 Title: CORN_LOOP_RECREATE=YES, does not work
Symptoms: Corner loops are not recreated when the default say Yes.
Previous/Known workaround: No known workaround exists.
Solution: Correction for automatic re-creation of corner loops has been done.
77019 160453 Title: Missing Parts in PLCM Nest
Symptoms: The message that there is a part missing and a small triangle is
drawn in the left bottom of the nest.
Previous/Known workaround: No known workaround exists.
Solution: Fixed so the part is included.
77324 161267 Title: PPANPARTS on a Panel with big excess at one limit failed
Symptoms: When excess is given and the value is more than 250 mm,
ppanparts will fail to create the plate part.
Previous/Known workaround: No known workaround exists.
Solution: When splitting a planar panel that includes excess, the limit for excess
is 250 mm.
This limit can now be controlled via IP to ppanparts:
MAX_EXCESS,<value>,
where <value> is the maximum allowed excess that ppanparts will handle.
78309 164288 Title: SBH_MARKING_SURF_TOL does not work
Symptoms: Defining the tolerance via SBH_MARKING_SURF_TOL has no
effect. It always use the default tolerance of 2 mm.
Previous/Known workaround: No known workaround exists.
Solution: The problem is handled and the user defined tolerance will be used.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 348 of 517
Product Release Letter

Hull Weld Planning:

Incident Issue Description


Number Number
63883 117303, Title: Weld suspension file is invalid for SB model
117367 Symptoms: Weld suspension on reflected part is not calculated.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the weld suspension on reflected parts are calculated.
71775 145666 Title: Necessary weld line has been missed since AM12.1.SP4.14.
Symptoms: A weld line at a curved flange end is missing.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the missing weld lines at the profile edge is included.
71825 145802 Title: After executed "Detect weld", system does not create any weld lines.
Symptoms: After executed "Detect weld", system does not create any weld lines
for round bar.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so also the round bar is recognized for welds.

Hull Nesting:

Incident Issue Description


Number Number
72154 146787 Title: Nesting PosNo Symbol for Plate Part is not working properly in AM12.1
SP4
Symptoms: The symbol defined by POSNO_SYMB in Nesting is not working. No
symbol is used.
Previous/Known workaround: No known workaround exists.
Solution: Corrected so the symbol assigned to POSNO_SYMB is used in the
position number setting.
72719 148511 Title: Extra zeros of ship number in nesting sketches
Symptoms: In the sketch resulting from 3 axis nesting, the ship number has an
additional extra zeros presented in the ship number.
Previous workaround: No known workaround exists.
Solution: Fixed so the correct ship number is presented.
73116 149530 Title: Plate nesting can't be saved
Symptoms: After getting the message "object currently locked by another user"
when trying to open a Nesting, no nestings are possible to save.
Previous/Known workaround: Exit and restart Nesting.
Solution: Corrected so no restart is required.
73462 150387 Title: Not able to make more than one rest plate in one raw plate.
Symptoms: If the Nesting default REST_PLATE_NAME is set to 2, only one
restplate can be created.
Known workaround: No known workaround exists.
Solution: Fixed so multiple resplates can be created.
75406 155294 Title: Missing degree symbol in Nesting bevel notes
Symptoms: Degree symbol is not showing in bevels in the Nesting Sketch.
Previous/Known workaround: No known workaround exists.
Solution: The error has been corrected so the degree symbols is visible. Note
that the degree symbol is only supported for True Type Fonts.
42904 157641 Title: MAX_CONTOUR over 200
Symptoms: The value of MAX_CONTOUR sometimes must vary which makes it
difficult for the operator.
Previous/Known workaround: No known workaround.
Solution: The problem has been corrected. New nests should have
MAX_CONTOUR = -1.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 349 of 517
Product Release Letter

Marine Drafting:

Incident Issue Description


Number Number
59363, 103533, Title: Consistent representation of unfinished PIPE and HVAC
59364 103534 Symptoms: Misleading drawings showing tube which may be incomplete or
unrouted.
Previous/Known workaround: Not adding piping and hvac elements to
drawings before their design is complete.
Solution: The core drawing engine now pays attention to the TEXIST pseudo-
attribute and suppresses the drawing of the tube itself where it is false.
67384 130422 Title: Strange line in the section view
Symptoms: Having a big depth defined in a symbolic view, some intersecting
panels are not at the correct location.
Previous/Known workaround: Make the drawing depth smaller.
Solution: The intersecting panel will be presented at the correct place in the
symbolic view.
72725 148520 Title: Autotagging - fail to delete local tag rules.
Symptoms: You get an error message - "Element GLABEL xxxx is locked". The
delete is interrupted leaving GLABELs element generated by the tag rule behind
Previous/Known workaround: No known workaround.
Solution: The problem is fixed. Deleting tag rules should not work as expected.
72981 149264 Title: Justification error in PosNo - positioning in "Annotate - Hull Note - PosNo"
Symptoms: The position number in the posno symbol is not centred.
Previous/Known workaround: Manually move the position number inside the
symbol.
Solution: Justification of the text in the pos no symbol is changed to be in the
centre of the text position.
73637, 150872, Title: HULL NOTE: too much spacing between dimensions and quality
70985 142941 Symptoms: The distance between the dimension string and the quality string in
the Hull Position number note is too big.
Previous/Known workaround: No known workaround exists.
Solution: The spacing between the dimension and the quality is corrected to be
one space.
74549 153037 Title: Print Error (Area Capture)
Symptoms: When activating the function "Capture Area" in the Print Dialogue,
after indicating the first position realizing that it was the wrong position, it is not
possible to cancel the function.
Previous/Known workaround: Indicate second position and restart from
beginning with first position again.
Solution: User can cancel printing operation.
74846, 153371, Title: Material info in Shell Expansion View
74883 153475 Symptoms: When the thickness of the shell plate is changed, the system leaves
also the old material information in the view.
Previous/Known workaround: No known workaround exists.
Solution: The material info was doubled and happened when there were no
suffix for the main and deck surface in Inithull. This has been solved so that it is
only written once. The Shellx drawing has to be remade.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 350 of 517
Product Release Letter
Incident Issue Description
Number Number
76412 158655 Title: Not all elements get copied from a HIDDEN LINE view to a new WIRELINE
view
Symptoms: Having a UNIVERSAL HIDDEN LINE view, there is an element that
is HIDDEN and does not get displayed. If changing the view to MODELLED
WIRELINE then the HIDDEN elements re-appears (which is to be expected).
However, if copying all the elements from the UNIVERSAL HIDDEN LINE view
into a new MODELLED WIRELINE view then the HIDDEN elements do not get
copied ... they get lost.
Previous/Known workaround: No known workaround exists.
Solution: Problem solved by removing the automatic purge during save (as)
operation.
76929 160539 Title: When Subpicture Regroup Menu 4.Polygon(CUT) execute, Current Scale
Changed to 1:1
Previous/Known workaround: Manually change scale.
Solution: When regrouping geometry to a new owner view, the transformation &
projection information from the view of first collected geometry will be copied to
the new owner view.
163670 Title: Listing subpictures sometimes gives faulty results
Symptoms: Listing subpictures sometimes returns subpictures that do not match
the search criteria given. This happens only when subpictures are stored in
directories, and not in the database.
Previous/Known workaround: None
Solution: This has been corrected so that only subpictures matching the search
criteria are returned.

Diagrams:

Incident Defect Description


Number Number
73519 153884 Title: Colours
Symptoms: There were no colour mapping option (except layers)
Previous/Known workaround: Change colours in diagrams or try to use layer
settings.
Solution: New options has been introduced: "Fill colour", "Text colour" and "Item
colour".
73729, 159067, Title: Export to DWG
78062, 163786, Symptoms: Attributes stored in shape data were exported to dwg. In the result,
73519 153884, when explode block in DWG, the attributes appears as texts.
162411 Previous/Known workaround: No known workaround.
Solution: A new option has been introduced that allows user to skip shape data
when export to DWG.
77861 163784 Title: UNDO
Symptoms: Unexpected exception when move elements that do not have
Diagxpos and Diagypos shape data property next undo.
Previous/Known workaround: Refresh items before move.
Solution: Unexpected exception message is no longer displayed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 351 of 517
Product Release Letter

Mechanical Equipment Interface:

Incident Defect Description


Number Number
62345 113206 Title: MEI: Special characters in imported equipment names
Symptoms: When an equipment is imported using Mechanical Equipment
Interface, if the name contains special characters like $, @ ... they will appear in
the equipment name.
Previous/Known workaround: Manually check the names before import to
contain valid characters.
Solution: Characters @ and $ are now replaced before creating database
elements for imported equipments.
66346 126199 Title: AUTOTAGG_Taggs for GENPRI
Symptoms: not possible to use Annotate-->Label on imported Equipments.
Previous/Known workaround: No known workaround exists.
Solution: The Mechanical Equipment Interface import has been changed in that
way that it transforms the GENPRIs so that the POS attribute refers to the
minimum point of the bounding box of the GENPRI.

Outfitting:

Incident Issue Description


Number Number
45010 58288 Title: Application not appearing on taskbar on load.
Symptoms: Application loads but does not appear on the taskbar until it is in
focus.
Previous/Known workaround: Alt-Tab will show the application has loaded,
then upon clicking it will reappear in the taskbar.
Solution: Forced the main window the show and gain focus which causes the
application to appear in the taskbar.
40212 65505 Title: EDG pick offset function.
Symptoms: Returning an offset position from an EDG pick was possible with the
old pick settings form, but this is regarded as difficult to use
Previous/Known workaround: Use the old pick settings form
Solution: Introduce a new pick offset form with only Cartesian offset, and with
immediate access from the EDG pick control toolbar.
44524 67859 Title: Design - Replace Design Template description only if description of source
object is set.
Symptoms: On create form, description typed in by user is cleared if copy object
has empty description
Previous/Known workaround: Retype description.
Solution: Checks for description set on the object to be copied.
48230, 75286, Title: Isodraft - Suppress Isodraft Spec Break tags for certain Specs
46031 86884 Symptoms: Spec Breaks are shown for all Specs.
Previous/Known workaround: No known workaround.
Solution: Set new SPEC attribute IGNBRK true to suppress the Spec Break tag.
58227 99146 Title: Design - Attribute Window crash
Symptoms: Attributes Window crashes
Previous/Known workaround: No known workaround.
Solution: This has now been corrected.
59447 103949 Title: Isodraft - Add the value of a PIPE UDA to the continuation note.
Symptoms: PIPE UDA cannot be shown in continuation note.
Previous/Known workaround: No known workaround.
Solution: Extend the CONTNOTES command.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 352 of 517
Product Release Letter
Incident Issue Description
Number Number
56504 114397 Title: HVAC - Development of standard HVAC nozzles on Standard Equipment
Symptoms: Branch Head XY size was not same size as nozzle XY.
Previous/Known workaround: Put in correct value.
Solution: System picks up the Branch XY size from connected nozzle.
69950 140380 Title: Structures - New Trim To Panel function.
Symptoms: The existing functions that perform this action require more mouse
clicks than the new function.
Previous/Known workaround: Use existing Mitre or Extend functions.
Solution: New button added to steel utilities toolbar to invoke the new Trim To
command.
70920 142627 Title: PDMS 12.1.SP4 DIST problem.
Symptoms: DISTANCE command not giving correct position.
Previous/Known workaround: Use other positioning commands.
Solution: This has now been resolved.
72241 148822 Title: Piping - Connecting two flanged branches head and tails normally results
in a Datacon error
Symptoms: after connecting the head of one branch to the tail of another you
can get:
FLANGE 2 =23584/11974
E730 LEAVE CONNECTION TYPE NOT COMPATIBLE WITH TCONN
or
GASKET 1 =23584/11975
D430 BAD ARRIVE CONNECTION TYPE
These errors are due to the need to switch just one of the head/Tail connection
types
Previous/Known workaround: Identify the problem and set the connection type
attribute by keyboard
Solution: The connection code now evaluates the connection types during the
connection process and makes the head/tail attributes compatible. Note: it
requires a complete flanged joint to be able to resolve the connection so in some
cases it will be necessary to reconnect the head/tail after appropriate
components have been built.
150624 Title: PSI is not compatible with CAESAR 2014
Symptoms: Output to CAESAR is ok but the return fails to build any components
Known workaround: use an older version of CAESAR
Solution: A change in the CAESAR Displacement output format is now
incorporated in the CII reading process.
76525 158974 Title: Validation of Equipment penetration across multiple panels improved
Symptoms: Validation of Design Template Equipment penetration across
multiple panels fails when penetration is valid.
Previous/Known workaround: No known workaround.
Solution: Validation test fixed.
76900, 160235, Title: Equipment - Negative primitive is not refreshing
76921 160270 Symptoms: Graphics out of date.
Previous/Known workaround: Re-add the equipment.
Solution: Negative Primitives now graphically refreshing.
160917 Title: HVAC pseudo attribute ARRWI ARRHEI LEAWID LEAHEI should be
Length Distance not Bore Distance.
Symptoms: HVAC data checking gives spurious errors.
Previous/Known workaround: No known workaround.
Solution: Checking now works.
77425 161503 Title: Piping - ADIR & LDIR pseudo attributes now work for TUBI
Symptoms: LDIR returns blank & ADIR gives wrong results.
Previous/Known workaround: Use branch components values.
Solution: This has now been corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 353 of 517
Product Release Letter
Incident Issue Description
Number Number
77060 161523 Title: Piping - The specborechange form fails to find components from some
specs and the user needs to choose them manually
Symptoms: .The message "Unable to search answers as there seems to be a
problem with the specification for this component type" appears when selecting a
series of components and the selection remains empty.
Previous/Known workaround: the user has to use the manual selection option
(Choose) for these components
Solution: In certain cases this is due to trying to evaluate real attributes as
strings. This fix handles both.

12.1.SP4.21

General:

Inciden Issue Description


t Number
Number
40793 155194 Title: Low performance in the search function
Symptoms: The search function takes far too long time when searching for
elements.
Previous/Known workaround: No known workaround exists.
Solution: The Search Utility has been updated to make faster searches.
Search beneath any element (SITE/ZONE/BLOCK …) is recommended.
A search throughout the whole MDB (search beneath element: /*) will still take
time but is also improved.

Marine Drafting:

Incident Issue Description


Number Number
76047 157732 Title: Activate the subpicture.
Symptoms: It takes very long time to activate a large sub-picture in Marine
Drafting.
Previous/Known workaround: No known workaround exists.
Solution: Performance during highlighting the subpicture has been significantly
improved.
76048 157733 Title: Copy the subpicture, performance
Symptoms: It takes very long time to copy a large subpicture in Marine Drafting.
Previous/Known workaround: No known workaround exists.
Solution: The performance during Copy Subpicture has been substantially
improved.
76049 157736 Title: Regroup the subpicture, performance.
Symptoms: Regroup of large sub-pictures take very long time.
Previous/Known workaround: No known workaround exists.
Solution: Performance during Subpicture Regroup and also Subpicture Split has
been significantly improved.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 354 of 517
Product Release Letter
Diagrams:

Incident Issue Description


Number Number
72257 147153, Title: Unhandled exception window is coming when we are selecting the
142176 linebreak option present in the shape tab after grouping the whole diagram .
Symptoms: Unhandled exception when 'linebreaks' or 'show text' commands are
used on some shapes.
Previous/Known workaround: Avoid using those commands on unsupported
shapes (after grouping some shapes and importing as different type of shape).
Solution: Ribbon buttons are now disabled when unsupported shape is selected.
73515 150394 Title: DWG Export from Diagrams- Revision Cloud layer truned off.
Symptoms: Invisible layers are visible in DWG files after export.
Previous/Known workaround: Remove unwanted layers before export.
Solution: Invisible layers will be now exported to DWG as 'turned off' layers.
75938 157531 Title: SCDUCT can't show pseudo attributes.
Symptoms: Querying BOREAR attribute of SCDUCT crashes diagrams.
Previous/Known workaround: No known workaround exists.
Solution: Added safety checks in code to prevent crash.

Engineering:

Incident Issue Description


Number Number
76068 157773 Title: DS Excel Export produce wrong Datas on Mass
Symptoms: Datasheet which has an attribute mapped to a UOM is exported in
German machine, value in the exported datasheet is incorrect.
Previous/Known workaround: Exported data should be independent of the
machine culture.
Solution: Made changes so that the values in the exported Excel display
according to the culture of the machine on which the application is running.

Pipe Fabrication:

Inciden Issue Description


t Number
Number
57390 96834 Title: Excesses not included in Material and Cutting List quantities.
Symptoms: Excesses not included in Material and Cutting List quantities.
Previous/Known workaround: None.
Solution: Derive excesses from PPIECE UDAs :PFCutlength and :PFFinlength.

Outfitting:

Incident Issue Description


Number Number
40058 66681 Title: Design - Graphical measurement in Primitive form input fields.
Symptoms: This facility is not currently available.
Previous/Known workaround: Perform a measure operation and manually
transcribe the result into an input field.
Solution: Measure button placed next to each primitive distance parameter input
field.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 355 of 517
Product Release Letter
Incident Issue Description
Number Number
44959 67811 Title: Design - Format of 'world axis' within Model View.
Symptoms: XYZ not shown in Model view axis.
Previous/Known workaround: Set COORD XYZ on the command line.
Solution: The default COORD setting has been forced to XYZ on entry to
Paragon.
62461 113492 Title: Isodraft - Couplings with Skey CP** break tube for Spool Drawings.
Symptoms: Different Cut Pipe pieces either side of Coupling.
Previous/Known workaround: None.
Solution: Suppress Spooler creation of implied for Couplings with Skey CP**.
72014 146366 Design - Clasher is not running when PDMS is installed in a folder with a blank.
75171 154550 Title: Design - Make window (Reorder/include/Reverse Order) larger.
Symptoms: Long names overflow field so are difficult to find
Solution: Reorder hierarchy form has been replaced. It now contains grids and
is able to be resized. Include form can also now be resized and default list width
has increased.
157873 Title: Isodraft - Number of character mismatch [3]Insert Depth: 0mm -3
Symptoms: Number of character mismatch [3]Insert Depth: 0mm -3
Previous/Known workaround: None.
Solution: Do not attempt to place spool number against 'End of skew' after Non-
standard branch connection.
76235 158160 Title: Design - Model View form creating SLOO and SVER elements in the
wrong place.
Symptoms: If the CE is moved, the Model View forms 'Modify Points' button can
create SLOO/SVER elements under an under a new or incorrect SEXT.
Previous/Known workaround: Avoid moving the CE unnecessarily while
working with the Mode View form - note that the Representation form will
sometimes move the CE.
Solution: Set the CE correctly at the start of the Modify Points code.
76390 158588 Title: FTUB leave tube not numbered.
Symptoms: Spool Drawing isometric cannot be created.
Previous/Known workaround: No known workaround.
Solution: Number FTUB leave tube.
158861 Title: Minor UI changes to the Search UI.
Symptoms: Search UI currently makes it too easy to perform large searches.
Solution: Slight adjustments have been made to the search UI in order to reduce
risk of long searches. They are still possible to perform but the user needs to
explicitly set it up. For more information see section Enhancements above.
76512, 158944, Title: Isodraft - Bending Machine stretch factors ignored in isometric Cutting List.
76536 158991 Symptoms: Incorrect Cutting List when Pipe Fabrication used.
Previous/Known workaround: No known workaround.
Solution: Derive excesses from PPIECE UDAs :PFCutlength and :PFFinlength.
76515 158982 Title: Getting twice the value of user excess, into the iso cutting list.
Symptoms: Getting twice the value of user excess, into the iso cutting list.
Previous/Known workaround: Remove flow arrows.
Solution: Allow for flow arrows when handling user excesses.
76545 159034 Title: Show Pipe Fabrication PPIECE names on isometric.
Symptoms: PPIECE names not shown.
Previous/Known workaround: No known workaround.
Solution: New PPIECE command. For more information refer to section
Enhancements above.
76872 160108 Title: Design - Detail text attributes set to the literal text 'unset' rather being left
as empty strings.
Symptoms: In design, detail text appear as 'unset' rather than being empty.
Previous/Known workaround: When modifying the detail texts using the
Paragon GUI, clear any field containing the string 'unset'.
Solution: On initialisation, fields are now blank.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 356 of 517
Product Release Letter

12.1.SP4.20

Assembly Planning:

Incident Issue Description


Number Number
73716 151057 Title: Assembly search via Insert Model does not work.
Symptoms: Assembly searching without given name does not work.
Previous workaround: Give assembly name path.
Solution: The problem has been solved so that assembly searching without
given name is working.

Planar Hull:

Incident Issue Descriptio.n


Number Number
65555, 123238 Title: Shell profiles as panel boundary is not possible
Symptoms: Using the "Profile Along" option in the Boundary statement on a
Shell Profile that does not belong to the main surface is not working through the
Statement Wizard.
Previous workaround: Manually change in trhe schema statement.
Solution: Solved so that it is now possible to use a profile as a boundary even if
it belongs to another surface.
151310 Title: Not possible to create limit along shell profile if limits are negative.
Symptoms: Using the "Profile Along" option in the Boundary statement on a
Shell Profile that does not belong to the main surface where the profile is across
the center line, is not working
Previous workaround: No known workaround exists.
Solution: Solved so that it is now possible to use a profile as a boundary even if
it belongs to another surface and across the center line.
157726 Title: Deteriorated performance when drag-dropping zones and above.
Symptoms: Drag-dropping a zone and above into the canvas takes longer than
in previous versions.
Known workaround: Do "ADD CE" in the command window.
Solution: The feature was removed.

Curved Hull:

Incident Issue Description


Number Number
75383 155458 Title: Curved plate name Suffix lost in Modify Form.
Symptoms: When modifying a Shell Plate, the suffix (position number) is
removed from the name.
Previous workaround: Manually add the prefix in the name field.
Solution: The full name is written in the plate name field.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 357 of 517
Product Release Letter

Hull Structural Design:

Incident Issue Description


Number Number
60218 106094 Title: Verfiy model crashes.
Symptoms: Verifying a panel containing a boundary reference along another
planar panel stiffener and the panel is missing, aborts the system. It is the same
also for Recreate of the panel.
Known workaround: Make sure the boundary definition of the panel is correct.
Solution: corrected so a proper error message is displayed instead of the
abortion of the system.
73994 152378 Title: FE-Model creation error, vector too short.
Symptoms: When creating a FE-Model from an Idealised model, the system
gives an error message:
Class: GoeVector3d
Method: UnitLength()
The vector is too short.
... and then aborts.
Previous workaround: No known workaround exists.
Solution: Corrected so the FE-model will finish.

Hull Production:

Incident Issue Description


Number Number
57916 98190 Title: Document links (HullPPI) have thousands of wrong refs, performance is
decreased.
Symptoms: There are many broken links to documents and drawings from the
MANU elements.
Previous workaround: No known workaround exists.
Solution: A new PML function, hullDeleteObsoleteLinks, is supplied with the
installation. This function will go through all LNDESC elements and remove any
element referring to a non-existent file or database element.
66316 125956 Title: HullMarkCreate method to creates Hull Mark object does not work in 12.1
Symptoms: Creating Hullmarks via MarAPI does not work at all.
Previous workaround: No known workaround exists.
Solution: Corrected so the API works and Hullmarks are created.
71898, 146173, Title: BENDING_INSIDE_PROFILE is invalid.
75300 155610 Symptoms: Bending information missing in profile sketch.
Previous workaround: No known workaround exists.
Solution: Corrected check against PROFILE_THICKNESS_LIMIT so that
bending information will be created only when profile thickness is less than
PROFILE_THICKNESS_LIMIT.
72042 146417 Title: Mount file has opposite END1 and END2 in case of over in CL panel.
Symptoms: Stiffener on the S-side of a CL panel (Y=0), the mount file has
shifted the value for END1 and END2.
Previous workaround: No known workaround exists.
Solution: Corrected so end1 and end2 is correct on both sides.
72079, 146794, Title: Burning Sketch Pos No is not coming Automatically for curve panel plate.
74114, 151839, Symptoms: Automatic position numbers are not automatically added to the
70644 142236 burning sketch for parts originating from curved plates.
Previous workaround: No known workaround exists.
Solution: The issue is now fixed and burning sketch pos no is now coming
automatically also for curved panel plate.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 358 of 517
Product Release Letter
Incident Issue Description
Number Number
75470 155865 Title: PLCM insert form.
Symptoms: PLCM aborts when inserting the drawing form right after the nesting
has been verified.
Previous workaround: After Verify, save nesting. Close nesting. Open nesting,
then insert form.
Solution: Corrected so drawingform can be inserted right after verification of the
nesting.
75639 156250 Title: Default surface is not listed after using SolveIntersectionXXX methods
Symptoms: After using the methode SolveIntersection, the list of default
surfaces in Curved Hull is empty.
Previous workaround: Open the dialouge Project-->Surfaces... then check the
Default surface list again.
Solution: The issue is corrected and teh list of default surfaces is not cleared out
after the methodes has been run.
75691 156446 Title: Missing SYMMETRY DataExtraction keyword for HOLE
Symptoms: When trying to extract the hole symmetry in Data Extraction, the key
word is missing.
Previous workaround: No known workaround exists.
Solution: The missing data extraction keyword SYMMETRY has been added to
the HOLE extraction. Also the missing keyword FICTIOUS has been added.

Hull Nesting:

Incident Issue Description


Number Number
74927 117640, Title: Limitied numbers of parts in Nesting when Parts Menu is used
153712 Symptoms: In case Parts Menu is used and filled up, it is not possible to read in
othert parts.
Previous workaround: Limit the Parts Menu with the filter.
Solution: No check on the number of parts is now made when the parts menu is
created. Currently, a maximum of 8000 can be listed.
When QuickNesting is used,however, the check is still present.
64904, 119463, Title: Detail Sketch is not created properly.
74127 120833, Symptoms: General problems in Nesting when creating automatic detail
142952, sketches.
143386, Previous workaround: No known workaround exists.
151857 Solution: The Detail Sketch handling in Nesting has been enhanced.
74114 151839 Title: Position number of other panel does not appear on Burning sketch.
Symptoms: Position numbers are missing in the Nesting Sketch.
Previous workaround: No known workaround exists.
Solution: Fixed so position numbers from other panels are shown in the sketch.
74127 151857 Title: Detail Sketch is not created properly.
Symptoms: General problems in Nesting when creating automatic detail
sketches.
Previous workaround: No known workaround exists.
Solution: The Detail Sketch handling in Nesting has been enhanced.
74927 153712 Title: Nesting, parts menue can only have number of parts related to
MAX_CONTOUR setting.
Symptoms: The number of parts in the parts menu is limited via the keyword
MAX_CONTOUIR.
Previous workaround: No known workaround exists.
Solution: No check on the number of parts is now made when the parts menu is
created. Currently, a maximum of 8000 can be listed.
When QuickNesting is used,however, the check is still present.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 359 of 517
Product Release Letter

Marine Drafting:

Incident Issue Description


Number Number
75206 154621 Title: Problem to change the apsect of Tahoma's letter when modify the
properties as bold.
Symptoms: When modify the font style of the texts with Tahoma font as Bold,
the aspect is changed.
Previous workaround: no known workaround exists.
Solution: Fixed so texts are correctly presented.
71768 145658 Title: Print-Capture Area cannot be aborted.
Symptoms: The Print-Capture Area function requires two cursor points. If the
first cursor point is set it is not possible to abort the function to correct the area for
printing.
Previous workaround: Finish the function with the wrong position and restart
from beginning.
Solution: User can cancel printing operation.

Diagrams:

Incident Issue Description


Number Number
130705 Title: AVEVA NET
Symptoms: When publishing to AVEVA NET more than one diagram in one go,
when critical error occurs, whole publishing process is stopped.
Previous workaround: No known workaround.
Solution: Publishing process continues working, even when critical error
occurred on during diagram export.
68372 135127 Title: Bug in behavior of line splitter
Symptoms: Branches are contained in wrong pipeline after pipeline split
process.
Previous workaround: No known workaround.
Solution: Implemented new splitting algorithm.
135197, Title: Error when removing PSPE.
137413 Symptoms: A fatal error occurred while removing the specifications for already
created pipeline and propagate changes.
Previous workaround: No known workaround.
Solution: System removes PSPE from elements without exceptions. Additionally,
when remove PSPE value system will ask if SPREF value should be erased also.
136417 Title: HVAC nozzle spec dialog allows to input special characters to the Shape
drop down list.
Symptoms: Inputting special character results in unhandled exception.
Previous workaround: No known workaround.
Solution: Drop down list style has been changed, so it is no longer possible to
input anything, only the elements available in list can be chosen.
144870 Title: Replace symbol from catalog.
Symptoms: Getting a invalid error by doing "replace symbol from catalog" on
nozzle.
Previous workaround: No known workaround.
Solution: System is using information from CATR for nozzles now, in the result,
"Replace symbol from cotalog" is now possible for nozzles.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 360 of 517
Product Release Letter
Incident Issue Description
Number Number
72361 156800 Title: AVEVA DIAGRAM: Export to DWG.
Symptoms: In some cases, there is an Aborted message during exporting to
DWG.
Previous workaround: Open VSD file in Visio, change (or set) font (in this case,
Green text from the attached V67127657-4883-10000-1.vsd) save it and try to
export again.
Solution:On some machines, font used in VSD file does not exisit in the system,
in this situation we are converting missing font to the default (Calibri) font.

Engineering:

Inciden Issue Description


t Number
Number
117802 Title: Tags - Navigation options are not enabled in HTML View tab in Report
Designer.
Symptoms: Navigation options are not enabled in HTML View tab in Report
Designer.
Previous workaround: No Previous workaround.
Solution: Enabled HTML View tab in Report Designer.
72458 148312 Title: Tags - Tags lists are deleted without user interaction.
Symptoms: If access to at least one folder where lists are stored is denied then
Tag's routine deletes all lists and additionally sometimes Admin tab is not visible.
Previous workaround: Tags user should be allowed to read from and write to all
folders where lists are stored.
Solution: Changed algorithm for storing lists and resolved an issue when user
had access denied for any directory.

Pipe Fabrication:

Inciden Issue Description


t Number
Number
72983 149208 Title: Mark Weld Info Turn of Highlighting.
Symptoms: When using the Weld Handling form the Mark Weld Info checkbox
turns off the highlighting from the Highlight Elements checkbox.
Previous workaround: No known workaround.
Solution: Program modified to keep highlighting.
67664 131094 Title: "Set to Miminum Feed Excess" should be inactivate.
Symptoms: The 'Set Minimum Feed Excess' that is available from the right click
menu of the 'Fabrication Checks' form should be greyed-out/inactive if the 'Allow
Automated Feed Excess' option has been selected on the 'Pipe Fabrication
Defaults' form.
Previous workaround: No known workaround.
Solution: Program modified to make inactivate the "set to Miminum Feed
Excess" if "Allow Auomated Feed Excess' option has selected on the "Pipe
Fabrication Deafult" form.
70047 140228 Title: Assign Slanted Pipe End Information.
Symptoms: The slanted pipe end information is only updated while Fabricated
Pipe End Form is activated.
Previous workaround: No known workaround.
Solution: Program modified to track db changes always.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 361 of 517
Product Release Letter

Outfitting:

Incident Issue Description


Number Number
38059 64878 Title: Deign - Cable way copy offset with graphical pick now calculated correctly.
Symptoms: Cable way was offset in the wrong direction.
Previous workaround: Use measure and type in offset.
Solution: Cable way copy offset with graphical pick now calculated correctly.
57292 96657 Title: HVAC - No notification of previous HVAC Connections made in a different
MDB session.
Symptoms: No alert just connects.
Previous workaround: Not applicable.
Solution: New alert if Branch already connected to element possibly in deferred
database.
60057 105910 Title: Design - STLNKS items should not appear in Paragon Explorer.
Symptoms: STLNKS items appear in Paragon Explorer.
Previous workaround: Ignore these items in the Explorer as they shouldn't be
there.
Solution: Add filter to make these invisible.
62053, 112122, Title: Isodraft - Isometrics for Pipes with certain Characters do not
75478 155847 show NSBC Detail Plot.
Symptoms: NSBC Detail Plot not shown on isometric.
Previous workaround: Rename Pipe.
Solution: Replace illegal characters by underscore in file names.
118894 Title: Isodraft - Cannot dimension to Grid.
Symptoms: Cannot dimension to Grid.
Previous workaround: No known workaround.
Solution: Add SKEY attribute to GRIDSY element .
64975 121260 Title: HVAC - HVAC head bore sometimes wrong by 90 degrees.
Symptoms: HVAC head bore sometimes wrong by 90 degrees.
Previous workaround: Transpose the AxB to BxA.
Solution: New button on HVAC main form to quickly resolve the bad orientation.
69104 138916 Title: Isodraft - NSBC Insert Depth text cannot be changed or switched off.
Symptoms: NSBC Insert Depth text cannot be changed or switched off.
Previous workaround: No known workaround.
Solution: Use Atext 394.
71727 145588 Title: Piping - PLANE command in BACKWARDS mode.
Symptoms: Missplaced component when using PLANE command in
BACKWARDS mode.
Previous workaround: Dont use BACKWARDS.
Solution: Now corrected.
73412 150126 Title: Continuation co-ordinates are different on the header and branch
isometrics.
Symptoms: Continuation co-ordinates are different on the header and branch
isometrics.
Previous workaround: No known workaround.
Solution: Ignore 'Ghost welds' associated with 'Ghost gaps'.
68043 153812 Title: HVAC - SpecGaug error the first time a place a UDF.
Symptoms: Undefied variable error.
Previous workaround: Try again and problem goes away.
Solution: Handle the error and default a default.
74491 152663 Title: Pseudo ABOP of HVAC components is bad calculated.
Symptoms: Returns position of the ppoint.
Known workaround: Write a PML function
Solution: Now fixed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 362 of 517
Product Release Letter
Incident Issue Description
Number Number
75042 154130 Title: Draft - Crash in mass property calculation
Symptoms: A data-dependent crash in the geometry engine.
Known workaround: None satisfactory (although small perturbations to the data
did avoid the crash).
Solution: A core fix has been made in the geometry engine to avoid a crash in a
rare geometrical configuration.
75421 155579 Title: Design - Copied elements are copied to the correct owning element.
Symptoms: Copied elements are copied to the wrong owning element.
Previous workaround: Copy and then change hierarchy
Solution: Previous bug fix improved to use correct target element.
76156 158017 Title: Panel negative not refreshing.
Symptoms: Change a panel hole & graphics does not refresh.
Known workaround: Re-add panel.
Solution: This has now been corrected.

12.1.SP4.19

Planar Hull:

Incident Issue Description


Number Number
50730 90444 Title: Panel Draw Code do not applied.
Symptoms: When "Thin" panels are shown in the 2D canvas in Global Hidden
Line, the result is not correct.
Previous workaround: No Previous workaround exists.
Solution: Corrected so the Global Hidden line is correct for "Thin" plates. As a
consequence, also the 3D view will present "Thin" plates.
72664, 148171, Title: OSP Bent Plate, transfer ignore bevels for profiles.
72665 148172 Symptoms: Bevel fittings are ignored by transfer and bevel codes are not added
in to scheme files.
Previous workaround: No Previous workaround exists.
Solution: With this fix negative bevels are transfered.
73038 149315 Title: Problem not to define User Defined Endcuts (UDE) into Pillar.
Symptoms: UDE's cannot be used for pillars or welded flanges.
Previous workaround: No Previous workaround exists.
Solution: Same functionality as for stiffener is now in place for both pillars and
flanges.
73724 151181 Title: Shell Profiles are not calculated correctly according to defined limit box in
Painting Area result.
Symptoms: Curved panels are not divided. Always full panel calculated.
Previous workaround: No Previous workaround exists.
Solution: Evaluating surface area using sloped deck panel fails. This is now
corrected.
74150 152001 Title: PLANE (PLN) Statement - restriction in string length.
Symptoms: when the default keyword LP_TERM_OUT is set to 0 (zero), the last
digit in the plane statement is missing.
Previous workaround: Manually add the last digit.
Solution: Corrected so the full plane statement is correctly presented.
74396, 152585, Title: Text unmoveable after you have updated symbolic view with "Replace
74413, 152586, existing view".
75034 154110 Symptoms: You cannot move the text, it will jump back to its original position.
Previous workaround: Do "update annotation" on the view.
Solution: The problem is fixed, you should now be able to move the text after
you have done "Replace existing view".

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 363 of 517
Product Release Letter
Incident Issue Description
Number Number
74211 152976 Title: LIS statement not written into scheme.
Symptoms: When using the keyword LIS in a panel statement for a knuckled
panel, the keyword is missing in the created schema file.
Previous workaround: No Previous workaround exists.
Solution: Corrected so the LIS keyword is present in the panel statement for
knuckled panels.

Curved Hull:

Incident Issue Description


Number Number
71104 143326 Title: When run Jig pillars, Fatal error occurs on Hull design.
Symptoms: An Unhandled Exception when running Batch Jig Pillars.
Previous workaround: No Previous workaround exists.
Solution: The Unhandled Exception is corrected.
72296 147239 Title: Extract Control form fails to load due to invisible Marine elements.
Symptoms: System reports error (2,118) when loading the form.
Previous workaround: Form requires re-coding to avoid COLLECT MEMBERS
syntax.
Solution: Fixed - Form avoids using COLLECT MEMBERS.

Hull Production:

Incident Issue Description


Number Number
69105 137533 Title: CONNECTION_TRACE is strange in Gen.file.
Symptoms: Output information in the generic file for curved profiles sometimes
just gives start and endpoint and the message "Graph converted to line" is written
in the logfile.
Previous workaround: No Previous workaround exists.
Solution: Corrected so that CONNECTION_TRACE intervalls will appear in the
generic file and so that message "Graph converted to line" will not appear in the
log-file.
72042 146417 Title: Mount file has opposite END1 and END2 in case of over in CL panel.
Symptoms: Stiffener on the S-side of a CL panel (Y=0), the mount file has shifted
the value for END1 and END2.
Previous workaround: No Previous workaround exists.
Solution: Corrected so end1 and end2 is correct on both sides.
73113 149510 Title: The Bevel side of flange to be defined into the SB specific panel is wrong
Symptoms: The bevel side of flange to be defined into starboard specific panels
is reversed.
Previous workaround: No Previous workaround exists.
Solution: Corrected so the bevel side is correct.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 364 of 517
Product Release Letter

Hull Nesting:

Incident Issue Description


Number Number
66362 126409 Title: PS shell stiffeners in SB shell plate.
Symptoms: Portside partname information is displayed on the starboard plate in
Nesting.
Previous workaround: No Previous workaround exists.
Solution: Corrected calculation of partname for longitudinal and transversal
markings.
70644 142236 Title: How to setup nesting sketch to display parts list in numerical order.
Symptoms: In the Nesting Sketch, the drawing rule 3110 in the part table is not
working correctly.
Previous workaround: No Previous workaround exists.
Solution: Corrected so the drawing rule 3110 is sorted correctly.

Marine Drafting:

Incident Issue Description


Number Number
70112 140381 Title: Delete By Area is no longer removing empty subpictures
Symptoms: When using the function Delete by Area, the empty sub-views are
not removed.
Previous workaround: No Previous workaround exists.
Solution: For more information see section Enhancements above.

Diagrams:

Incident Issue Description


Number Number
65570 123225 Re-open Error.
66721 142825 Diagrams “Out Of Memory” error when publishing to AVEVA NET.
153584 Title: Functions used in latest version of sample project are missing in PMLLIB.
Symptoms: There is new PBS example introduced in latest version of sample
project, but PMLLIB is missing functions used in the definition. This causes an
error during module start-up and invalid PBS explorer display.
Previous workaround: Log in into ENGINEERING MDB instead of SCHEMATIC
or ALL.
Solution: The funcions have been added and Diagrams is working on sample
project without problems.
Note: Removing pml.index from PMLLIB or calling "pml rehash" is needed for
existing installations.

Engineering:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 365 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
74931, 67807, Title: Schematic Model Manager - An Err msg 'Unhandled exception' displayed
71274 153726, on exiting application after deleting an element in new explorer.
145477 Symptoms: An Err msg 'Unhandled exception' displayed on exiting app after
deleting an element in new explorer.
Known workaround: NA
Solution: Now no unhandled exception will occur on exiting app after deleting an
element in new explorer.
78312 Title: Compare/Update: Database Window; Hide irrelevant section.
Symptoms: Showing complete "Update Database" window even if there are no
items to be updated or inserted.
Previous workaround: No Previous workaround.
Solution: Showing only the relevant section of Update Database window.
110316 Title: Tags - Marked texts are not be over written.
Symptoms: By default whole text is selected in long text editor as soon as the
long text editor appear to the user during typing of text. It is bad behaviour
because first letter typed in the long text editor override selected text. Long text
editor behaviour should match standard text field behaviour (after pressing F2
text in long text editor is selected and ready to be overwritten).
Previous workaround: No Previous workaround.
Solution: 1. Text is not selected in long text editor when the long text editor
appear to the user during typing of text.
2. Long text editor behaviour matches standard text field behaviour (after
pressing F2 text in long text editor is selected and ready to be overwritten).
65326 122384 Title: PDF Export of Datasheets ignores page settings
Symptoms: PDF export generates multiple pages for a single sheet in the excel
of datasheet instance
Previous workaround: No Previous workaround.
Solution: Implemented code in pdf export so that single page will be generated
per sheet in the excel.
66762 127355 Automap in Datasheet Template.
129958 Title:Compare/Update - Unhandled exception when we try to select the mapping
attribute using arrow keys.
Symptoms: Application crashes if user uses down/up arrows to select mapping
attributes in attribute mapping form which is part of configuration creatuin/edit
wizard.
Previous workaround: No Previous workaround exists.
Solution: Application will not crash even if user uses down/up arrows to select
mapping attributes in attribute mapping form which is part of configuration
creatuin/edit wizard.
68320 134989 Title: Reporting - GetDouble, GetUnits, GetDimension function in an expression
in the Report Designer are not working with UDAs.
Symptoms: GetDouble, GetUnits, GetDimension function giving 0 value for
array UDAs.
Previous workaround: No Previous workaround.
Solution: GetDouble, GetUnits, GetDimension function are working as expected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 366 of 517
Product Release Letter

Mechanical Equipment Interface:

Incident Defect Description


Number Number
54499 90750 Title: Failed to export models (name contains multibyte charactors) when output
IGES files.
Symptoms: When a ZONE name includes multibyte characters, the IGES export
fails.
Previous workaround: Rename so it does not include any mutlibyte characters.
Solution: Corrected so export will handle also multibyte characters.

Multi-Discipline Supports (MDS):

Incident Issue Description


Number Number
149542 Title: Separate Style Support Creation.
Symptoms: Errors would occur when creating new style supports (E3D 2.1 and
later) in a support ZONE containing old style supports (E3D 1.1 and before).
Previous workaround: No Previous workaround.
Solution: It is now no longer possible to create old style supports in a ZONE
containing new style supports.

Pipe Fabrication:

Inciden Issue Description


t Number
Number
70917 142622 Title: Pipe Fabrication excesses are not included in the isometric material or
cutting lists.
Symptoms: Pipe Fabrication excesses are ignored.
Previous workaround: No Previous workaround.
Solution: Write excesses to Transfer File and process in Isodraw.

Outfitting:

Incident Issue Description


Number Number
28994 59571 Admin - 'Disallow claim' for SITE and ZONE does not provide the desired result.
39633 66325 Title: Vitesse Hull - FilterOperator.DoesnotEndWith in AttributeStringFilter does
not work.
Symptoms: Some string filter operators in .NET interface are not implemented.
Previous workaround: Can get collection and use standard .NET string
comparison.
Solution: Implement full set of string filter operators.
47147 72824 Title: Piping - When bran head starts tubi, a pspool has a bran in exported RVM.
Symptoms: Export file contains complete branch rather than just head tube of
pspool.
Previous workaround: No Previous workaround.
Solution: Don't scan entire branch belonging to pspool.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 367 of 517
Product Release Letter
Incident Issue Description
Number Number
67096 95900, Title: Spooler - Create correct IWELDs for PIPCA connections.
128691 Symptoms: Create correct IWELDs for PIPCA connections.
Previous workaround: No Previous workaround.
Solution: Create IWELDs for PIPCA connections using P-Point 1000 + PIPCA
Number.
57040 96826 Title: Admin - Performance of 'Extract' gadget in Extract Control form with large
Claim-lists.
Symptoms: With a large Extract Claim-list, clicking 'Extract' gadget takes several
minutes to respond.
Previous workaround: Use the Command-line to Extract Claim items.
Solution: Performance improved.
60057 105910 Title: STLNKS items should not appear in Paragon Explorer.
Symptoms: STLNKS items appear in Paragon Explorer.
Previous workaround: Ignore these items in the Explorer as they shouldn't be
there.
Solution: Add filter to make these invisible.
61739 111159 Title: The component creation form gives the wrong LSTU on the first new
component after switching branches.
Symptoms: It was possible to get the tube bore of the previous branch after
pressing the set branch button on the component creation form. This was due to
the select branch method not initialising the tube selection mechanism.
Previous workaround: Select the tube from the tube selection gadget.
Solution: The form now initialises properly on a new branch.
63877 118578 Title: Structures - Fitting BANG initialised correctly.
Symptoms: Create Fitting uses the SCTN BANG for its default value.
Previous workaround: Reset BANG field to the required value.
Solution: BANG defaults to 0 on first use in a session, and to the last used value
on subsequent use.
66047 124823 Title: HVAC - Ship coordinate dimension for connection points In HVAC sketch
Symptoms: End Point Table gives X Y Z not ShipX ShipY ShipZ
Previous workaround: No Previous workaround.
Solution: This is now possible if the word SHIP is used in the BTEX attribute of
any TEXP element in the ENDPOINT Table Entries of the Backing Sheet used as
the Template for the HVAC Sketch.
67096, 128691, Title: Isodraft - PTAP connection splits tube on Spool Drawing.
62451 113447 Symptoms: Cutting List splits tube at PIPCA.
Previous workaround: No Previous workaround.
Solution: Use Spooler generated IWELD for PIPCA connection.
67909 134462 Title: Design - Clipping (CLIP CE Not work in Imperial Units).
Symptoms: Blank graphics when clip CE in units other than mm.
Previous workaround: Not acceptable, but switch to mm units.
Solution: Now works as expected, in any distance unit.
69657 139043 Title: Piping - The NSBC utility always selects the default LSTU - it should take
into account the previous component tube instead.
Symptoms: incorrect wall thickness messages after a PTAP in DATACON.
Previous workaround: The user needs to select the lstu separately.
Solution: The PTAP in the main line now gets the same tube selection as the
previous component (or head) For new branches it also tries to select the
appropriate tube using the tube STYPE.
68593 141603 Title: Toolbar Docking.
Symptoms: Floating toolbar position not restored between application switches.
Previous workaround: Toolbars must be repositioned by hand after application
switch.
Solution: Restore floating toolbar positions.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 368 of 517
Product Release Letter
Incident Issue Description
Number Number
71727 145588 Title: Piping - PLANE command in BACKWARDS mode.
Symptoms: Missplaced component when using PLANE command in
BACKWARDS mode.
Previous workaround: Don’t use BACKWARDS.
Solution: Now corrected.
71984 146261 Title: Pipe Fabrication generated Spools require CSFBR to be set as well as
ASFBR/LSFBR.
Symptoms: Inconsistent Spool Breaks generated from Pipe Fabrication.
Previous workaround: Set CSFBR attribute.
Solution: Remove reliance on CSFBR attribute also being set when setting
ASFBR/LSFBR in Pipe Fabrication.
72013 146459 Title: Datal output does not distinguish ambiguity between Word and unit
qualifiers in parameter lists.
Symptoms: Interpretting a WORD a unit for a preceding number in a parameter
list.
Previous workaround: Edit the data output by bracketing the preceding number
before input.
Solution: Bracketting numbers in parameter output lists which precede
ambiguous unit qualifier like words.
72093 146592 Title: Spooler - Spool Break at Tee off leg makes incorrect Spool Break attribute
settings.
Symptoms: Spool Break set at Tee PA/PL rather than at Off leg.
Previous workaround: Set TSFBREAK true for leave tube of Branch.
Solution: Set TSFBREAK true for leave tube of Branch for Spool Break GUI
selection and introduce new Create/Delete Spool Break OFF option for current
element.
72138 146693 Title: Design - Cabling Design license may be required to manage projects
containing Cabling data.
Symptoms: Deletion, locking and renaming of Cabling elements fails if Cabling
Design license is unavailable.
Previous workaround: None, other than to obtain a Cabling Design license.
Solution: Software fix to remove requirement for license for deletion, locking and
renaming of Cabling Design and Room Design related elements.
72617 147997 Title: Automatic Spool Regeneration fails to maintain attributes during pipe
changes.
Symptoms: Changing a pipe containing pspools does not mainiat individual
pspool attributes and sometimes the attributes are applied to a different pspool.
Previous workaround: Check the pspool attributes beforefinal issue
Cause: The old production checks utilities auto generate pspools each time a
pipe geometry is changed. The data elements in the old spools are re-used to
save data storage but this can result in the newly created pspools occupying
different db refs to what they started with. The core auto-regeneration simply
replaces the spool limit data and does not do anything to preserve existing
pspools.
Solution: Since 12.0.SP6, a PML routine has been used to compare the new
and old pspools before and after regeneration to preserve the spool names. This
has been sucessful in solving the name problem but never tried to maintain any
spool attributes. Now the comparison also compares and resets pspool attributes
values including UDA values.
73018 149280 Title: Admin - Infinite recursion problem with unknown elements.
Symptoms: Applications may hang, or Explorer and the command line may
display invalid member lists for unknown element types.
Previous workaround: Avoid referencing databases from later product versions
than the software being used.
Solution: Software updated to prevent infinite recursion with unknown elements.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 369 of 517
Product Release Letter
Incident Issue Description
Number Number
73483 150314 Title: Equipment penetration validation failing for penetrations in more than one
panel.
Symptoms: Equipment penetration validation failing following hole approval
Previous workaround: No Previous workaround.
Solution: Approved penetration of second and subsequent panels now
recognised correctly, and hole alignment checking improved.
73721 151256 Title: Spooler - FTUB component not numbered by update.
Symptoms: FTUB component has Partnumber 0 after Number update.
Previous workaround: Use Number renumber.
Solution: Number FTUB with SKEY of TUBE on update.
151349 Title: PML error in Extract Control form after EXTRACT ISSUE DB.
Symptoms: Error reported as (2,779) Method <ERROR>.SIZE() Not found on
line 1407 of admExtractCntrol.extractItem.
Previous workaround: Problem only occurs after commands such as
EXTRACT ISSUE DB which do not include an item-list.
Solution: Correction required to PML.
152743 Title: Database and data Management - Delay and eventual crash opening
PDMS Design 12.1.SP4 on APS project for E3D 2.1.
Symptoms: Delay and eventual crash opening PDMS Design 12.1.SP4 on APS
project for E3D 2.1.
Previous workaround: No Previous workaround.
Solution: Software fix to correct forwards compatibility behaviour.
74720 153097 Title: Isodraft - Fonts incorrectly exported to dxf from IsoDraft
Symptoms: Text using (eg) Cyrillic characters exported incorrectly
Previous workaround: No Previous workaround.
Solution: Code modified to export data as escaped Unicode and specify
appropriate font in exported dxf.
74738 153146 Title: 3D views not updating in Paragon
Symptoms: Modifying catalogue item geometry does not redraw the image of
the component in the model view form.
Known workaround: Open the representation form and press Apply to force an
update
Solution: Modified code that checks which changes to ignore.
153157 Title: Isodraft - Blank Bolt descriptions generated for a single character Bolt
Description replacement text.
Symptoms: Blank Bolt descriptions.
Previous workaround: Use longer replacement text.
Solution: Cater for a single character Bolt Description replacement text with
multiple occurrences.
74790 153226 Title: Design - 3D views not updating in Paragon.
Symptoms: Modifying catalogue item geometry does not redraw the image of
the component in the model view form.
Previous workaround: Open the representation form and press Apply to force
an update.
Solution: Modified code that checks which changes to ignore.
75055 155970 Design - Apply button on CATE GUI does not change graphic representation.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 370 of 517
Product Release Letter

12.1.SP4.18

Reporting:

Incident Issue Description


Number Number
68462 135383 Title: Report scope from PMLReport object.
Symptoms: When PML function creates report and scope for report is set
through MyData selection which has unnamed elements, the generated report
skips the unnamed elements.
Previous workaround: No Previous workaround exists.
Solution: Now report scope can contain both named and unnamed items.

Data Base and Data Managament:

Incident Issue Description


Number Number
65695 123697 Title: Upgrade Problem in SP4.
Symptoms: Admin crash when trying to upgrade a hull data base.
Previous workaround: No Previous workaround exists.
Solution: Corrected so upgrade works.

Assembly Planning:

Incident Issue Description


Number Number
70144 140477 Title: Get Work executed by one user causes the 3D-view to be updated with
another user's modified objects.
Symptoms: Get Work is updating the Drawlist which makes the Assembly views
confusing.
Previous workaround: No Previous workaround exists.
Solution: Drawlist for the 3D graphics is no longer updated at Get Work.
Only assemble states in Design Explorers is updated!

Initial Design:

Incident Issue Description


Number Number
64109 120156 Title: CALC - Missing detailed reports of deterministic stability for critical damage
cases in probabilistic report.
Symptoms: Missing detailed reports of deterministic stability for critical damage
cases in probabilistic report.
Previous workaround: Use the default damage case title, default is equal to id.
Solution: Changed search routine for damage cases to search in id field with
search criteria as id.
65431 122626 Title: New group buttons enabled also for Local/Shared Location nodes in tree
view.
Symptoms: The New Group butto in the main toolbar were not active when
Local/Shared Location nodes were selected in tree.
Previous workaround: Use Menu/Pop up menu instead
Solution: Code change to enable the button.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 371 of 517
Product Release Letter
Incident Issue Description
Number Number
68753 136200 Title: Calc crashes when opened on the Citrix server.
Symptoms: Calc crashes when opened on the Citrix server.
Previous workaround: No Previous workaround exists.
Solution: Corrected so Calc will start also on the Citrix Server.

Planar Hull:

Incident Issue Description


Number Number
68278 56347, Title: Manage holes handling problems.
134843 Symptoms: Hole Management fails to approve holes made for an Equipment
and the error message "Unable to create the hole" is presented.
Previous workaround: No Previous workaround exists.
Solution: This normally means that there are too many segments in the resulting
curve that will form the hole. The curve statement gets trunkated after 1000
characters. Meaning that the curve created by the MNG hole function might
corrupt the scheme. This has been corrected by just copying the contour and
reduce the curve statement to 'CUR, "CURVENAME", MNG;'
A Managed curve like this is not allowed to be changed by the hull Designer.
21190 60970 Title: REF keyword not automatically added to boundary.
Symptoms: In Statement Wizard when indicating a reflected Shell Profile, the
REF keyword is not added to the resulting statement.
Previous workaround: Add REF manually to the statement.
Solution: Corrected so REF will automaticcally be included in the statement for
reflected Shell Profiles. Views created prior to this fix must be recreated before
indication.
23781 68751 Title: Position number series of standard bracket would not be applied.
Symptoms: Position number series of standard bracket would not be applied and
displayed when using statement wizard, that is, POS=1(1)12.
Previous workaround: Manually change from individual pos no's to group (i.e.
from 1,2,3,4,5 to 1(1)5 ).
Solution: The StatementWizard will now accept repetition terms for the position
numbers of brackets, both in the form of for example 1(1)5 and 1,2,3,4,5.
65555 123238 Title: Shell profiles as panel boundary is not possible
Symptoms: Using the "Profile Along" option in the Boundary statement on a
Shell Profile that does not belong to the main surface is not working through the
Statement Wizard.
Previous workaround: Manually change in the schema statement.
Solution: Solved so that it is now possible to use a profile as a boundary even if
it belongs to another surface.
60001 105069 Title: To be able to select which components to be drawn in symbolic view.
Symptoms: -----
Previous workaround: No Previous workaround.
Solution: Layers on components in the symbolic view can, with this change, be
customized. The componets that can be affected are the same as the ones that
can be defined for colour and line type.
Keyword LAYER=<layer_no> is added to the syntax of the SVIEW_LT_COL
object definition.
63652, 116609, Title: Material thickness value of plates gets negative (-) value after Panel
68967 137095 Recreate on FRP project.
Symptoms: The material thickness value is changed by the system.
Previous workaround: Manually change it to correct value.
Solution: Corrected so the system will not change the sign of the material
thickness.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 372 of 517
Product Release Letter
Incident Issue Description
Number Number
64579 119370 Title: After PPI executes, the panel edge is reduced by the value of Gap * 2.
Symptoms: When having multiple bevel gaps defined on the same Planar Panel
limit, the resulting plate part size is wrong.
Previous workaround: No Previous workaround exists.
Solution: Corrected handling of multiple bevel gap intervals on one plate panels.
65534 123116 Title: R1=0 and R2=0 is not acceptable for cutout 9999 intercrossing panels.
Symptoms: Giving R1 and/or R2 as zero (0) always adds a KS10 notch to the
9999 cutout for intercrossing panels.
Previous workaround: No Previous workaround exists.
Solution: Zero is acting as default value and will then use the default notch KS10
for cutout type 9999. By setting the environment variable
SBH_NO_INTERCROSS_RAD to any value, R1=0/R2=0 will be treated as if no
notch is desired.
65555, 123238, Title: Shell profiles as panel boundary is not possible
37663 69361 Symptoms: Using the "Profile Along" option in the Boundary statement on a
Shell Profile that does not belong to the main surface is not working through the
Statement Wizard.
Previous workaround: Manually change in trhe schema statement.
Solution: Solved so that it is now possible to use a profile as a boundary even if
it belongs to another surface.
66193 129273 Title: The Virtual hole was inconsistent with real hole.
Symptoms: In Hole Management, an arbitrary hole on Starboard side is not
correctly displayed in Hull Design. The radius is displayed wrong.
Previous workaround: Manually change sign of the curve in the CUR statement
for the wrong radius parameters.
Solution: Non standard holes will be generated correctly on reflected planar
panels.
67425 130000 Title: "Outside" of GUI is checked if you modified to a plate without "DIS" on the
scheme.
Symptoms: In a FRP project, when a plate is not set "DIS" in the scheme,
"Outside" in GUI is automatically checked. This leads to wrong definition of
material.
Previous workaround: Manually check if DIS is checked or not.
Solution: The problem is now solved so that the Outside tickbox shows the
correct value for the plate being modified.
67747 131355 Title: Partly plate repesentation not display in the knuckle panel.
Symptoms: Some small parts in a knuckled panel is missing.
Previous workaround: No Previous workaround exists.
Solution: Corrected so all parts will be visible.
68201 134649 Title: Knuckle panel disappear from deck view.
Symptoms: When changing thickness of a deck panel, the abutting knuckle
panel is removed from the symbolic view.
Previous workaround: No Previous workaround exists.
Solution: This often happens when the thickness is increased. If the knuckled
panel is more than 15 mm from the view plane, it was considered to be outside
the view. This tolerance is now changed to 100 mm instead of 15 mm.
68812 136387 Title: Bead in FRP quality extracted always 'A' via DEX.
Symptoms: Using Data Extraction trying to extract the quality of a Bead, the
quality is always returned as zero (0).
Previous workaround: No Previous workaround exists.
Solution: Coreccted so the quality code (and quality text) is extracted from the
Bead.
68879 136664 Title: Frame number being inserted into Marking Text Rotation (UVT).
Symptoms: Opening a planar panel schema containing marking with free text,
the T (angle) is adding a FR term to the angle like T=FR0-90.
Previous workaround: Manually remove the FR term from the value.
Solution: Corrected so no FR/LP term is added to the T angle.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 373 of 517
Product Release Letter
Incident Issue Description
Number Number
69734, 139260, Title: FRP - When the panel receated, bead object in design tree is created once
72050 146433 more.
Symptoms: When the panel receated, bead object in design tree is created once
more but it is not included in the schema.
Previous workaround: No Previous workaround exists.
Solution: Corrected so no extra bead is created and the model is correctly
displayed also in the schema file.
69738 139268 Title: FRP- In Stiffener Statement, LAM keyword drops in statement wizard.
Symptoms: When modifying a stiffener in the Statement Wizard, the LAM
information is lost in the Wizard.
Previous workaround: Manually add the lamination code.
Solution: Corrected so the Wizard will fill in the correct lamination code.
69748 139313 Title: Scheme Input Function vs. Hole Management Tool
Symptoms: Using Input Scheme containing a Managed Hole is not possible to
run. The HOL statment will always fail.
Previous workaround: No Previous workaround exists.
Solution: To make 'safe' handling both interactive and batch any panel with
managed holes will be stopped at panel statement to prevent corrupt panel (with
missing holes).
To update these panels remove reference or run panel/edit or panel/recreate.
69784 139439 Title: After stiffener inclination value is up to 10 EA, recently value is not applied.
Symptoms: The inclination field in the Statement Wizard is not presenting the
correct value.
Previous workaround: Manually modify to the correct value.
Solution: The correct inclination value is presented in the drop down list. If no
inclination is given in a stiffener, the field will be set to blank (i.e. no inclination).
70248 141032 Title: Attribute KNUCKL wrong for KL Brackets.
Symptoms: The bracket has no folded flange and still the attribute is ticked for
knuckle.
Previous workaround: No Previous workaround exists.
Solution: The attribute KNUCKL for brackets has been corrected to be correct
ticked/un-ticked.
70592 141889 Title: 3pts Panel does not display on curved panel view.
Symptoms: Panels defined with 3 points are not shown in the Curved Panel
view.
Previous workaround: No Previous workaround exists.
Solution: Corrected so all planar panels touching the Curved Panel will be
included in the Curved Panel View.
70642 142061 Title: Plane Panel Activate Options.
Symptoms: When activating a panel, the use of Options to present a popup
menu for typing of panels to be included or excluded for selection does not work.
Previous workaround: No Previous workaround exists.
Solution: The Selection dialog is now shown at Options.
71005 142915 Title: Tests on Solid Shell Plates / New Holes.
Symptoms: Various problems to display shell plates such as "Missing Transom
Shell Plate", "Badly Formed Bilge Radius Plate".
Previous workaround: No Previous workaround.
Solution: Display of shell plates has been improved.
71343 144209 Title: Creation of Bevel object in inithull happened error.
Symptoms: Adding more than 100 AUTO_SETs will give errors in the logfile
when creating the bevel object in inithull.
Previous workaround: Make sure there are less than 100 sets in the bevel
definition.
Solution: Limit has been increased to 250 sets.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 374 of 517
Product Release Letter
Incident Issue Description
Number Number
71880 145978 Title: Panel-store trigger not started when renaming panels.
Symptoms: When renaming Planar Panel, the trigger when storing the panels
are not started.
Previous workaround: Make a modification on the renamed panel and save it
again.
Solution: The trigger is now started also in the Rename function where an Apply
Panel is executed.
72024 146401 Title: Panel store post trigger executed too early.
Symptoms: Modifying symmetry for a panel e.g. from P to SBP, the trigger for
the reflected image of the panel is saved after the trigger has started.
Previous workaround: No Previous workaround exists.
Solution: Trigger is started when all internal save operations are done.
73386 150052 Title: System aborts when notches are defined on a twisted stiffener (Planar
Panel).
Symptoms: When adding a notch to a planar panel stiffener that is twisted, the
system aborts when the panel is saved.
Previous workaround: No Previous workaround exists.
Solution: Corrected so the system will save tha panel with the added notches on
the stiffener without aborting.

Curved Hull:

Incident Issue Description


Number Number
50911 81710 Title: Display PosSB error in the Curved hull view.
Symptoms: Position number in the Curved Panel View for SB plates are shown
as 0 (zero).
Previous workaround: No Previous workaround exists.
Solution: The problem has been solved so that the SB plates show correct
posno on the curved panel view.
52246 86283 Title: TBID Val and Part ID for shell profile and Data extraction problem for shell
profile
Symptoms: Extracting shell Stiffener Part ID in Data Extraction gives no result
(Hull.Trans(no).Part('part name').Pro.Part_id.Sho).
Previous workaround: No Previous workaround exists.
Solution: Corrected so the Part ID is correctly extracted.
67867 132927 Title: Problem not to cancel the modification function in Curved Modeling.
Symptoms: When modifying a seam and user would like to canel the opration, it
is not possible if the seam is made by a plane with 3 points.
Previous workaround: No Previous workaround.
Solution: Solved so that the Cancel function works for Modify Seam Curve Plane
3 Points.
68528 135493 Title: Fatal Error when form was closed without name and open again.
Symptoms: If no name is given when using the function Create Curve in Curved
Hull, the program aborts.
Previous workaround: Make sure a name is given to the curve.
Solution: Corrected so if no name is given, the message "Invalid name" will be
given to the user.
68783 136862 Title: SBH_ENABLE_SOLID_PLATES and out of range of spatial map error.
Symptoms: Gets strange message "Box dimension for item <plate name> is out
of range of spatial map" when modifying shell plates where holes are applied.
Previous workaround: No Previous workaround exists.
Solution: This has to do with holes with sharp corners and the problem has been
fixed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 375 of 517
Product Release Letter
Incident Issue Description
Number Number
72443 147619 Title: Shell Profile Inclination Problem.
Symptoms: Shell profile is presented with wrong inclination angle.
Previous workaround: No Previous workaround exists.
Solution: Corrected so Shell Profile is presented correctly. Error is only in case
Shell Plate exists in the area.

Hull Structural Design:

Incident Issue Description


Number Number
15723 56251 Title: Block Divide for a specific panel.
Symptoms: Not possible to handle just a single Design Panel in Block Ssplitting.
Previous workaround: No Previous workaround exists.
Solution: This is now done so that populating the production model from the
design model using the new interface is possible. This also means that single
design panels can be handled.
56038 94000 Title: Seperate stiffener statements in transversal func. Panels.
Symptoms: When generating transversal panels in RSO the stiffeners are
generated in seperate statements and not in groups which is the case for panels
generated from RSOs in Y and Z planes.
Previous workaround: No Previous workaround exists.
Solution: Stiffeners generated in transversal panels will also be grouped.
57509 97096 Title: Block can not be handled (drag&drop, exporting as rvm file) but it is ok in
SP3.
Symptoms: System aborts when the block is to be presented.
Previous workaround: No Previous workaround exists.
Solution: Corrected so the block can be correctly displayed (and exported).
58794 101496 Title: Possible to split Design Panels.
Symptoms: In a multiview project system allows user to generate parts for a
design panels via right click function " Generate Parts" in design view mode.
Previous workaround: Avoid using the function in "Design View Mode".
Solution: "Generate Parts" is now grayed out for design panels (and idealized
panels and bracket panels).
65140 121568 Title: In design panel, wrong form pops up and flange dissapear after accepting
pending update.
Symptoms: In design panel, wrong form pops up and flange dissapears after
accepting pending update.
Previous workaround: No Previous workaround exists.
Solution: Handling of cut flange in hole is now implemented in a multi-view
environment.
65139 121572 Title: Delete panel in a Global MultiView project.
Symptoms: Deleting a production panel will not remove the highlighting and it
looks like the panel is not deleted.
Previous workaround: Restart the application after delete operation.
Solution: Corrected so the production panel is deleted correctly.
65143, 121573, Title: Create one-to-one panels in Global MultiView project.
65173 121659 Symptoms: After selecting Pending Updates, the system hangs.
Previous workaround: Make sure user has write access to the design data base
in use.
Solution: Correction for handling of non-write data base access.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 376 of 517
Product Release Letter
Incident Issue Description
Number Number
65142 121574 Title: Design Panel gets wrong stiffener ends for topologic points.
Symptoms: Topology point for stiffener end that is created for a Production
Panel stiffener is not correctly transferred to the Design Panel.
Previous workaround: No Previous workaround exists.
Solution: If the profile end is not the same for the Production Panel as for the
Design Panel, the topological point referring it will be changed to a direct point.
65171 121642 Title: Errors when trying to modify symmetri of production panel in MultiView
project.
Symptoms: System gets confused when the Design Panel data base is a read
only data base when trying to modify symmetry of a Production Panel.
Previous workaround: Make sure all databases included are writable.
Solution: To be able to change symmetry on a production panel or a design
panel with production panels they all need to be in databases with write access. If
not, an error message is given and the function terminates.
65464 122718 Title: Not possible to copy panel from a prod block to another prod block
belonging to another desi block.
Symptoms: When trying to copy a Production Panel from one block to another
block the system is responding with the message: 'Invalid Block selected!'
Previous workaround: No Previous workaround exists.
Solution: The copy function is modified to accept copying between production
blocks belonging to different design blocks.
68278 134843 Title: Hole management fail to “Approve” on some HPANEL.
Symptoms: Hole Management fails to approve holes made for an Equipment
and the error "Unable to create the hole" is presented.
Previous workaround: No Previous workaround exsits.
Solution: This normally means that there are too many segments in the resulting
curve that will form the hole. The curve statement gets trunkated after 1000
characters. Meaning that the curve created by the MNG hole function might
corrupt the scheme. This has been corrected by just copying the contour and
reduce the curve statement to 'CUR, "CURVENAME", MNG;'
A Managed curve like this is not allowed to be changed by the hull Designer.
68146 135198 Title: Problem for restrinction in symbolicview.
Symptoms: When making a Detail View, the checkbox for restricted view is
checked if the original view was restricted.
Previous workaround: Uncheck the tickbox manually.
Solution: Corrected so the restriction tick box will always be unchecked for detail
views.
71047 143048 Title: Some Beams are not connected to shell elements in FE model.
Symptoms: Topologically correctly defined profiles connected to the shell are
sometimes not connected correct in the FE model.
Previous workaround: No Previous workaround exists.
Solution: Corrected so the shell connection is also correct in the FE model.
71521 144804 Title: MULTIVIEW - Stiffeners disappear after block division
Symptoms: After running Block division the stiffeners are missing in the resulting
panels in the target block.
Previous workaround: No Previous workaround exists.
Solution: Fixed so all components are available in the target panel after Block
Division.
71522 144809 Title: MULTIVIEW - Seams missing in design panel when created pll to another
seam
Symptoms: When seams have been created parallel to another seam in the
production panel, the seams are not populated to the design panel in a Multiview
model.
Previous workaround: No Previous workaround exists.
Solution: Seams referring another seam now correctly handled in design panel
update.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 377 of 517
Product Release Letter
Incident Issue Description
Number Number
71508 145111 Title: None or more than one contour from the RSO
Symptoms: Problems in the boundary when using RSO's with multiple faces.
Previous workaround: Manually add correct face number in the schema
statement.
Solution: The multiple intersections of faces was not handled in the best way.
The solution is now improved in handling multiple intersections.
71636 145314 Title: Hull Steel XML Export- Export component/part name
Symptoms: Request to get names of exported components in the XML file from
Hull Steel Export.
Previous workaround: -----
Solution: A name attribute is exported for those components which are also
exported as geometry via MEI.
The exported name attribute is
- the name of the component if given, otherwise
- the part name
If neither of them is given no name attribute is exported.
71761 145647 Title: Wrong type of shell elements.
Symptoms: All shell elements are MEMBRANE type in exported BDF file. They
should be PLATE type.
Previous workaround: No Previous workaround exists.
Solution: The material ID in field MID2 in the PSHELL entry has been added.
72928, 149865, Title: Problem for IntersectionPointsGet(MarContourPlanar Contour1,
53675 89017 MarContourPlanar Contour2).
Symptoms: No intersection is found by the API.
Previous workaround: No Previous workaround exists.
Solution: The API has been corrected.

Space Management:

Incident Issue Description


Number Number
66698 127048 Title: Paint Area Calculation gives wrong results in Space Management.
Symptoms: Paint Area gives wrong result when Curved Area is included.
Previous workaround: No Previous workaround exists.
Solution: Corrected so also Paint Area is correct when Curved Area is included.

Hull Production:

Incident Issue Description


Number Number
63102 115549 Title: OSP Top level DESI database when split.
Symptoms: If an included foreign( *) database (DESI type) is top level, when a
framework(PANE) is split within ppanparts the message from log viewer is
"'Couldn't create new PanelType2! No panels found with given input '".
Previous workaround: Make sure first DESI data base is not write protected.
Solution: Corrected so a user can split outfitting elements, using temporary block
created automatically.
63442 116200 Title: Edge Template marking is cut in the middle.
Symptoms: Edge Template marking is divied into two parts.
Previous workaround: Increase the second value for the EDGE_TEMPLATE IP.
Solution: Correction has been made to how the edge template position is
calculated.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 378 of 517
Product Release Letter
Incident Issue Description
Number Number
67657 131095 Title: Invalid Bending Template and Table information about forward block.
Symptoms: Template not created and message "Plate edge is too far from hull
surface" in the log file.
Previous workaround: No Previous workaround exists.
Solution: Normal case for this is that the intersection of the plates results in two
curves. in such case, the intersecion plane will be moved until there are only one
resulting curve. Information is also given in the log-file.
69304 138099 Title: Font setting for GenFile Viewer.
Symptoms: System is using TBSystemFont0 in the Genfile Viewer.
Previous workaround: No Previous workaround exists.
Solution: The text font is taken from the Nesting default parameter TEXT_FONT.
71455 144719 Title: Data Extraction Error for flat bar.
Symptoms: The second time a stiffeners total length is extracted, the wrong
length is presented.
Previous workaround: No Previous workaround exists.
Solution: The problem has been solved so that the stiffener length remains the
same after wcog are extracted.
71500 144756 Title: Customer Postprocessor.
72866 148832 Title: PLC-module:system does not handle reflected symmetrical panel.
Symptoms: Error 105 is given in the log file when splitting (ppanparts) a
symmetrical panel for PLCM.
Previous workaround: Make side specific panels.
Solution: Corrected so a symmetrical panel is split to be used in PLCM.
73548, 150701, Title: ATX Export delivers wrong results.
73791 151178 Symptoms: Profiles on symmetrical planar panels do not get P and S in the part
names in the ATX file.
Previous workaround: No Previous workaround exists.
Solution: Corrected so that the name of profile parts will end with 'P' or 'S'.

Hull Nesting:

Incident Issue Description


Number Number
67750 130800 Title: IND_PART_TEXT Modification.
Symptoms: IND_PART_TEXT_3 is written like 15583+417. Expected result is
the sum of both like 16000. (real milling length).
Previous workaround: No Previous workaround exists.
Solution: A new default parameter, IND_PART_TEXT_ACT, has been
introduced for the display of text3 and text5. The following values are possible:
= 0 Display the terms as a sum
= 1 Display the sum of the terms
70418 141335 Title: Nesting sketch with two or more pages cannot be stored.
Symptoms: Not possible to store nestings that contains more than one nesting
sketch page.
Previous workaround: No Previous workaround exists.
Solution: Corrected so all old sketches are removed before the new sketch
pages are saved.
71829 145826 Title: Nesting:Variable "START_DIR_HOLE " in SBH_NEST_DEF2 doesn't work.
Symptoms: When changing the value of START_DIR_HOLE, the system
automatically change it to another value that keyed in.
Previous workaround: Double click on the value until correct value is set.
Solution: Corrected so the value keyed in will remain.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 379 of 517
Product Release Letter

Hull Weld Planning:

Incident Issue Description


Number Number
59994 104959 Title: Unnecessary weld line created on the bracket.
Symptoms: After defect welds, there is an unnecessary weld line on the bracket.
Previous workaround: No Previous workaround exists.
Solution: The unnecessary weld will not be created.
68701 125840, Title: The weld lines are not split around slot areas.
136014, Symptoms: Weld not stopping correctly at cutout.
147148, Previous workaround: No Previous workaround exists.
125853 Solution: Corrected so the weld is stopping correctly at the cutout.
68700 136013 Title: The weld lines for clip and long are not created.
Symptoms: Weld lines between clips and penetrating longitudinals is missing.
Previous workaround: No Previous workaround exists
Solution: Corrected so the weld lines are created.
68701 136014 Title: The weld lines are not split around slot areas.
Symptoms: Weld not stopping correctly at cutout.
Previous workaround: No Previous workaround exists.
Solution: Corrected so the weld is stopping correctly at the cutout.

Marine Drafting:

Incident Issue Description


Number Number
50732 82376 Title: Need loosing of restriction after changing projection.
Symptoms: After copy of a sub-picture, the 2D restriction window is moved if the
projection in the sub-picture is changed.
Previous workaround: Manually remake the restriction window.
Solution: The restriction window will stay at the same place after change of
projection.
53230 87842 Title: Adding a default keyword for the views VGAP attribute.
Symptoms: Currenlty, when creating a new view its VGAPlength attribute is
always 1.5mm.
Previous workaround: Set the VGAPLENGTH attribute on the VIEW elements
to zero or a much smaller value than currently set on pictures which show the
problem, then there would be a significant improvement.
Solution: A new drafting default keyword, "VIEW_VGAP" to select the initial
value of VGAP for a new view, has been added.
VIEW_VGAP is 0.0 by default.
56894 96644 Title: Arc and Circle Smoothness.
Symptoms: The dxf exported from Aveva has the value of "Arc and Circle
Smoothness" set to zero. The valid values are 1 ..... 20000.
Previous workaround: No Previous workaround.
Solution: The default value for Arc and Circle smoothness is now 1000.
64404 118774 Title: Transfer subpicture not possible if drawing name is longer than 26 chars.
Symptoms: Function File -Transfer does not work correctly if drawing name is
longer than 26 characters.
Previous workaround: Keep names shorter than 26 chanracters.
Solution: Handling of long names (more than 26 characters) now implemented in
Transfer function.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 380 of 517
Product Release Letter
Incident Issue Description
Number Number
65067 121270 Title: Curved panel corner can not be selected in 12.1.SP4.
Symptoms: Curved panel corner can not be selected but this was possible in
earlier versions.
Previous workaround: Include the shell plates wherer it is possible to select
corners.
Solution: Corrected so the Curved Panels corners are selectable as event
points.
66785, 128809, Title: SCTN ends are not being properly defined in all View Types
53230 87842 Symptoms: Currenlty, when creating a new view its VGAPlength attribute is
always 1.5mm.
Previous workaround: Set the VGAPLENGTH attribute on the VIEW elements
to zero or a much smaller value than currently set on pictures which show the
problem, then there would be a significant improvement.
Solution: A new drafting default keyword, "VIEW_VGAP" to select the initial
value of VGAP for a new view, has been added.
VIEW_VGAP is 0.0 by default.
130401 Title: Tools> Model View> Copy for Symbolic View allows User to Choose
Projection.
Symptoms: You can select a new projection for a Symbolic View although this is
an irrelevant operation. The change has no effect on the result.
Previous workaround: No Previous workaround.
Solution: For Symbolic Views the Choose Projection option has been removed.
67548 130646 Title: Command UPDATE BSHEETS does work.
Symptoms: The command will have no effect - there ar eno updated.
Previous workaround: You can use the MARAPI function
"DwgReloadBackingSheet".
Solution: If you make the SHEET active and use the UDPATE BSHEETS
command it should now work, the backing sheet it updated.
68733, 136125, Title: Character Limit for Multiline Text.
71695 145480 Symptoms: Multi line text is restricted to 2048 characters.
Previous workaround: No Previous workaround exists.
Solution: Changed to allowing up to 30000 characters in a text element.
Note that there is still a limitation of approx 1000 characters in PADD. Exceeding
this limitation means that the text will not get persisted.
68839 136450 Title: The Properties of Planar Hull View is not working for Free Text(Marking).
Symptoms: In the function View-->Properties, trying to blank out Marking Text,
the text is still visible after unticking the Mark Text tick box.
Previous workaround: No Previous workaround exists.
Solution: Corrected so Marking Text will be unvisible if the Mark Text tick box is
unchecked in the View Properties dialouge.
70385 141408 Title: Shell Expansion shows overlaped Position Numbers on Stbd side when
refreshing old view.
Symptoms: When modifying position numbers on starboard side shell plates, the
numbers are wrong in ShellX views.
Previous workaround: Manually change the numbers in the views.
Solution: Corrected so the number will be correctly presented for the starboard
plates.
70559 141656 Title: Enhancement to automatically add arc fillets without radius value.
Symptoms: In Tribon it was possible to use "Automatic" fillet radius in the
Trim/Fillet function.
Previous workaround: No Previous workaround exists.
Solution: The "automatic" fillet radius concept is now avaialable again by leaving
the Radius field empty.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 381 of 517
Product Release Letter
Incident Issue Description
Number Number
72789 148642 Title: Problem to update design models in a view when insert models by Drag
& Drop.
Symptoms: When adding models in views via drag & drop, If the view type is
Global hidden in 12.1SP4.x , the whole desing models at the view have been
updated.
Previous workaround: Change the view type before adding new models to the
view.
Solution: The behavior is correct but an option has been introduced to prevent
the system from doing an Update Design when adding design models to such
view.

Diagrams:

Incident Issue Description


Number Number
72524 147691 Title: Resize is not behaving as expected for inline components when working
without specification.
Symptoms: When working without specification, resize function was giving
unecessary question about leave bore for components with arrive set to value
other than 1. In addition, cancelling questions for such component was causing
unexpected exception.
Previous workaround: Working with directional components only as they have
always arrive set to 1 and leave to 2.
Solution: The problem has been solved and resize works properly for all inline
components now.

Engineering:

Inciden Issue Description


t Number
Number
67783 Title: Schematic Model Manager - An error message 'Unhndld excpton' is displyd
while deleting the Diagram in Schematic Explorer.
Symptoms:While deleting a diagram through context menu in schematic
explorer 'Unhandled exception' occurs.
Previous workaround: No Previous workaround.
Solution:Now there will be no exception message occurring while deleting a
diagram. Diagram is deleted successfully.
61025 108660 Title: Tags - The 'Autorenaming active on attribute change' option is disabled by
default.
Symptoms: The 'Autorenaming active on attribute change' option is disabled by
default.
Previous workaround: No Previous workaround.
Solution: The 'Autorenaming active on attribute change' option is enabled by
default.
70571 141687 Title: Add a method on object PMLTAGS() to get the current list.
Symptoms: Getting the current list by PML API is not possible.
Previous workaround: No Previous workaround.
Solution: Added property ActiveGridName to PMLTags object that return the
name of currently active grid.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 382 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
71080, 143213, Title: SMM Diagram View Scale errors with imported XML file from SPPID.
71630 145315 Symptoms: When XML with units of distance other than mm is imported to SMM
then scale of drawing is not proper.
Previous workaround: No Previous workaround.
Solution: Now XML with any units of distance supported by ISO15926 is
displayed with proper scale in diagram viewer.
71676 145405 Title: Tags - Sublist header shows invalid unit.
Symptoms: Sublist header shows invalid unit.
Previous workaround: No Previous workaround.
Solution: Valid unit is shown.
70698 146136 Title: Tags application suspends when opening PipeBasicData list.
Symptoms: Tags application suspends when opening PipeBasicData list.
Previous workaround: No Previous workaround.
Solution: StackOverflowException issue fixed and Tags application does not
suspend when opening PipeBasicData list.

Mechanical Equipment Interface:

Incident Defect Description


Number Number
55113, 92167, Title: Fatal error when importing STEP file
58158 98880 Symptoms: System aborts when importing STEP file
Previous workaround: No Previous workaround exists.
Solution: The STEP file will be succefully imported.

Multi-Discipline Supports (MDS):

Incident Issue Description


Number Number
65340 Title: DM does not produce MTO files.
Symptoms: DM does not produce MTO files.
Previous workaround: No Previous workaround.
Solution: Upgrade MDS to work with DM.
149539 Title: Fix for Creating Multi-Discipline Frameworks on GENSECs.
Symptoms: Error messages displayed when creating a support framework on a
GENSEC element.
Previous workaround: No Previous workaround.
Solution: Functionality has been added for the creation of a support framework
to a GENSEC.
149623, Title: Issue with creating a support in a ZONE where its SITE isn't named.
149629 Symptoms: A syntax error would appear if you created a support in a support
ZONE where its owning SITE was not named.
Previous workaround: Name the SITE
Solution: Now it is not possible to select a support ZONE if its owning site is not
named.

Pipe Fabrication:

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 383 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
69575 139962 Title: Flanges with CompType of ALLO should not be defaulting to LOOSE.
Symptoms: Even if flange is ring type, it is treated as LOOSE as default.
Previous workaround: No Previous workaround.
Solution: If a flange's COMPTYPE is ALLO, the fabrication check form and
drawing will not notice it as "loose part".And it not allows to change LOOSE
attribute for the RING Type flange via modify attribute form.
72793 148687 Title: No DXF or PDF files produced in Piping Fabrication.
Symptoms: Cannot Export DXF or PDF files in Pipe Fabrication.
Previous workaround: No Previous workaround.
Solution: Program modified to use an iso option file to export DXF, PDF.
72232 148803 Title: Missing clutch reference.
Symptoms: If a tube is connected with an element which is shop false, clutch
reference would be missed.
Previous workaround: No Previous workaround.
Solution: Complemented the codes for element which is shop false.

Outfitting:

Incident Issue Description


Number Number
31461 60547 Title: Design - Ability to unset a structural storage area.
Symptoms: No unset storage area option is available.
Previous workaround: Show a hidden form that should not be seen by users.
Solution: Pop-up menu implemented in the storage area forms to unset a
storage area.
32517 78516 Title: Equipment - Improved calculation of box containing a GENPRI element.
Symptoms: Box size can be larger than expected.
Previous workaround: Manual edit to attributes.
Solution: Improved calculation of box containing a GENPRI element.
58748 101320 Title: Improved validation when creating Design Templates.
Symptoms: Error shown when converting to a Design Template a model that
has elements not permitted in a TMPL.
Previous workaround: Accept error and continue. Use UNDO if necessary.
Solution: Validation of original element improved so that it is not copied to a
TMPL if it contains illegal elements.
61290 110231 Title: Piping - LIMBOSPEC in a multi-user environment.
Symptoms: Does not work with Limbospec claimed by another user.
Previous workaround: One user at a time.
Solution: Creates a new limbospec.
65149 124006 Title: HVAC - MAS HVAC catalogue update required.
Symptoms: Flipping a HVAC TAPER did not update leave Tubing.
Solution: Run Macro PDMSUI/data/MAS-HVACupdate.pmlmac in MAS project
database MASTER/HVACCATA.
66740 127138 Title: Report Designer - Cancel Close command.
Symptoms: Your only option are to save or not. No matter what you choose the
program will be closed.
Previous workaround: No Previous workaround.
Solution: Added cancel button to allow user back to same window if don’t want
to save and cancel.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 384 of 517
Product Release Letter
Incident Issue Description
Number Number
69330 140329 Title: Admin (including Lexicon & Propcon) - DICE reports Fatal error when
Extract hierarchy requires synchronization.
Symptoms: FATAL DICE error reported for Child extract because it is out-of-
date.
Previous workaround: Synchronise the Extract Child at the Parent primary
location before running DICE checks.
Solution: DICE should report this as a warning in a Global project, not an error.
However Claim errors will be reported until the Parent extract has been
synchronised to the Primary location of the child.
71479 144750 Title: User in the WAIT state cannot be deleted.
Symptoms: System reports (1,37) This user is currently active
Previous workaround: Replace COMMs database. Alternatively ensure that all
User Slots in the WAIT state have been re-used. You can view the Slots in the
Comms database using Q SLOTS.
Solution: WAIT users no longer block deletion.
71572 145901 Title: Design - Copy fixing does not work.
Symptoms: copied FIXING is owned by the original.
Previous workaround: Use "Rel" option.
Solution: "END" added so that copied FIXING is not owned by the original.
72020 146373 Title: REAL( unit qualified value) not working
Symptoms: funny error message
Previous workaround: No Previous workaround.
Solution: This has now been corrected.
72272 147188 Title: Draft - Multiple nested symbols don't work correctly when SYTMs have
same last leaf (after last /).
Symptoms: Wrong symbol is used in exported DXF/DWG.
Previous workaround: Make sure SYTM names differ in their last leaf.
Solution: Code now uses full SYTM name.
72364 147295 Title: Design - When user executes function mirror copy, AVEVA Marine is not
responding..
Symptoms: Very slow to mirror with complex equipment.
Previous workaround: Remove item from drawlist before mirroring.
Solution: Now only drawn once.
72085 147375 Title: Draft - Only standard arrows double up in chained dimensions.
Symptoms: Open arrows, darts do not double up either side of projection line in
chained dimensions.
Previous workaround: No Previous workaround.
Solution: Code now treats all arrow-like terminators identically.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 385 of 517
Product Release Letter
Incident Issue Description
Number Number
72669 148212 Title: Draft - VSCAN syntax used with WITHIN and IN CE can return unintended
results.
Symptoms: VSCAN syntax which uses WITHIN <volume> and IN CE can be
phrased such that the results are probably not what the user intended.
Specifically, it is possible but not recommended to enter the following syntax:
Q VSCAN FOR SCTN WITHIN <volume> IN CE
In this case the “IN CE” forms part of the generic selection criteria syntax
(equivalent to “WRT CE”) and is unlikely to be what the user intended. The
results may be very different from the probable intent of syntax such as:
Q VSCAN IN CE FOR SCTN WITHIN <volume>.
Previous workaround: Drop the IN CE part of the command when used in
conjuction with the WITHIN selection criteria. IN view_id is in any case only
required when scanning views elsewhere in the database hierarchy: if the current
element is on or under a VIEW then the VSCAN command runs against this
VIEW automatically.
Solution: It is not possible to remove this syntax combination without breaking
the generic volume based selection criteria syntax. VSCAN documentation has
been updated to point out the potential confusion. In addition the VSCAN syntax
has been tweaked to move IN view_id to earlier in the command (without
breaking existing syntax)
Q VSCAN <SIGNIFICANT | design_id> <FOR selection_criteria> <IN
view_id>
has now become:
Q VSCAN <SIGNIFICANT | design_id> <IN view_id> <FOR
selection_criteria>
When using the new syntax tree IN CE before the selection criteria will produce
the expected results.
72688 148443 Title: Global - In a Global project, Extract Issue may not Release elements if
there is nothing to Extract Flush.
Symptoms: No Global command is raised, and the item(s) remain claimed.
Affects Global projects only.
Previous workaround: Use EXTRACT RELEASE to issue items.
Solution: The system now runs an EXTRACT RELEASE if Extract Flush is
unnecessary.
72944, 149088, Title: Admin - User cannot be deleted because it is still 'Active' having been
73003 149268 expunged.
Symptoms: Error (1,37) reported because user is in the WAIT state
Previous workaround: If you can, replace the COMMs database by a new one.
Otherwise wait 24 hours and enter PDMS a number of times to use up all WAIT
slots (Use Q SLOTS to find out which slots are in the WAIT state).
Solution: WAIT users no longer block deletion.
72982 149206 Title: Design - Align secondary node not working when a SNOD owns more than
one SJOI.
Symptoms: SNOD not moved when it owns more than one SJOI.
Previous workaround: No Previous workaround.
Solution: Move SNOD to align with joints, and create new SNOD for joints that
are not aligned.
149305 Title: Error message displayed while trying to construct a Constructed Line
Symptoms: (47,62) CP: Incomplete command line creating a constructed line
Previous workaround: No Previous workaround.
Solution: Corrected logic.
71882 149770 Title: Draft - MTO's in ISOADP lose last character of description.
Symptoms: Item descriptions truncated by 1 character.
Previous workaround: No Previous workaround.
Solution: Code adjusted so that trailing character only removed if it’s a space.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 386 of 517
Product Release Letter

12.1.SP4.17

Assembly Planning:

Incident Issue Description


Number Number
65010 122387 Title: DXF 3D error.
Symptoms: In DXF Export, if an assembly contains only a few parts from a
planar panel, the whole planar panel is exported.
Known workaround: No known workaround exists.
Solution: Corrected so only the parts in the assembly are exported. Existing
views must be recreated.

Planar Hull:

Incident Issue Description


Number Number
54295 90449 Title: Geometry lost problem as hull object creation.
Symptoms: Added geometry is cut off at the view limits when a panel schema is
executed.
Known workaround: This happens when added information is automatically
added to the closest component. Make sure the Current Subpicture setting is not
set to Automatic.
Solution: Added geometry will not be clipped when the panel schema is
executed. Also the new added Drafting default keyword,
MODEL_COMPONENT_AS_CURRENT_ALLOW, should be set to No.
56231 94559 Title: Hole management issue on an imperial project.
Symptoms: Hole size and position incorrect in project setup with Imperial Units.
Known workaround: No known workaround exists.
Solution: Hole management approval function in Hull Design has been fixed for
an imperial project.
64175 117853 Title: Annoying error with stiffener inclination on statement wizard form.
Symptoms: The inclination field in the Statement Wizard is not presenting the
correct value.
Known workaround: Manually modify to the correct value.
Solution: The correct inclination value is presented in the drop down list. If no
inclination is given in a stiffener, the field will be set to blank (i.e. no inclination).
68596, 135729, Title: Symbolic View Creation, Select tab.
71543 144896 Symptoms: The Select tab in Symbolic View Creation form is always reset to its
initial state.
Known workaround: Manually change in the tab to correct values.
Solution: Select tab will not be reset after each time a symbolic view has been
created.
68595 139058 Title: 3D Event Point snapping, brackets
Symptoms: There are no Ppoints available on Brackets.
Known workaround: No known workaround exists.
Solution: Pponits to Hull Brackets have been added.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 387 of 517
Product Release Letter

Curved Hull:

Incident Issue Description


Number Number
67940 133364 Title: DIRECTION_TRACE value is strange for shell stiffener of S-Side in the
symmetry Block.
Symptoms: DIRECTION_TRACE value is strange for shell stiffener of S-Side in
the symmetry Block.
Known workaround: No known workaround exists.
Solution: When calculating DIRECTION_TRACE for profile parts, which are
derived from symmetrical shell stiffeners, it is now taken into account if the profile
part is valid for starboard or portside.
69769 139340 Title: AutoBevel of S-side Shell Stiff is strange.
Symptoms: The bevel of the shell profile trace is not correct on SB side when
using Automatic Bevel. It is ok on PS.
Known workaround: No known workaround exists.
Solution: The problem has been solved so that the angles for the SB only side
shell stiffener with variable bevelling will be correct in the generic file.
72243 147109 Title: It is not working marking info. for Shell plate.
Symptoms: In the Production Tab when trying to add Planar Panels to be
included/excluded in marking, no panels are added to the list.
Known workaround: No known workaround exists.
Solution: Corrected so Planar Panels can be indicated and included in the list.

Hull Structural Design:

Incident Issue Description


Number Number
59482 104013 Title: RSO Face ID Number is disappeared in scheme statement.
Symptoms: RSO Face ID Number disappears from the scheme Panel statement
when copied.
Known workaround: Manually add the correct Face ID.
Solution: When copying a panel to an RSO with multiple faces a ray is added to
the location definition pointing out a face. The ray is derived from the template
panel.
69956 140079 Title: FE-Modeller Version (with mesh and BDF export) - crash by function
reduced thickness.
Symptoms: FE-modeler crash when small holes are included.
Known workaround: No known workaround exists.
Solution: The handling of multiple holes in a small plate created unreasonable
geometries. The handling of holes for which to do thickness reduction has been
reworked to handle a greater variety of hole - plate configurations.
71043 143037 Title: Out of Plane Nodes of the FE model.
Symptoms: Planar panel faces close to a sculptured surface face could get
distorted.
Known workaround: No known workaround exists.
Solution: This is due improper use of tolerances internally and is now corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 388 of 517
Product Release Letter

Surface Manager:

Incident Issue Description


Number Number
65036 121250 Title: Surface Manager import, combines the curves
Symptoms: During the import of iges file into the Surface Manager, curves
exported in iges containing several curves end as surface file containing one curve
(e.g. 4 exported curves are merged into 1).
Known workaround: No known workaround exists.
Solution: Depending on how the curves are defined in the original CAD system
they are imported as follows:
- Unnamed curves are imported into different nodes with a synthetic name. (*)
- Named curves with the same name are merged into one node with the curve's
name.
- Named curves with different names are imported into different nodes with the
curve's name.
(*) In case the CAD system or the translator creates a synthetic name during the
export/import which is not unique, the user needs to give unique curve names in
the original system before the export to avoid unintended merging of the curves.

Hull Production:

Incident Issue Description


Number Number
63127 115563 Title: OSP - Justification line problem.
Symptoms: It is not clear how the justification line of a PANE element is handled.
Known workaround: No known workaround exists.
Solution: A correct contour will be created with respect to justification line of
PANE element.
70313 141058 Title: st002 execution stop with pillar
Symptoms: -----
Known workaround: -----
Solution: Customer specific program.

Hull Nesting:

Incident Issue Description


Number Number
70961 143164 Title: Not able to make more than one rest plate in one raw plate.
Symptoms: It is not possible to make a second restplate from a standard raw
plate.
Known workaround: No known workaround exists.
Solution: The error is corrected and it is possible to create more than one
restplate.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 389 of 517
Product Release Letter

Marine Drafting:

Incident Issue Description


Number Number
57453 96955 Title: Open Drawing Dialog - List of "General" drawings.
Symptoms: SHEET elements from the MAS project appears in the list.
Known workaround: Use name filter.
Solution: The drawings from the MAS project will not appear in the list any more.
59386 103622 Title: Insert Model does not work by Outfitting Name only.
Symptoms: Not possible to search for an individual Outfitting object in the "Insert
Model" form.
Known workaround: Use the add-in Search functionality.
Solution: Wildcards can now be used for searching outfitting names even if
nothing else is given. No wildcards can be used for the "zone" field.
61097, 108863, Title: DXF 3D error.
69263 138077 Symptoms: In DXF Export, if an assembly contains only a few parts from a
planar panel, the whole planar panel is exported.
Known workaround: No known workaround exists.
Solution: Corrected so only the parts in the assembly are exported. Existing
views must be recreated.
69552 138832 Title: Model views for assemblies is not working correctly
Symptoms: When using the input model by assembly, the result is an empty
view without assembly model.
Known workaround: No known workaround exists.
Solution: If the assembly model fails to be presented, a proper message will
inform the user.
69637 138938 Title: In MarineDrafting Module,it is invalid to Modify the Attribute: Plclearance
of object "DPOI"
Symptoms: Several attributes on DPOI element is not possible to modify in
Marine Drafting.
Known workaround: No known workaround exists.
Solution: Following attributes on dimension part level (elements NOUN_DPOI,
NOUN_DPPT) are now handled:
- Witness line gap (Plclearance, PlClFlag)
- Witness line excess (Overshoot)
- Dimension line type (DLStyle)
- Witness line type (PLStyle)
- Dimension line colour (DLColour)
- Dimension text colour (DTColour)
- Witness line colour (PLColour)
- Witness text colour (PTColour)
69804 139573 Title: After modifying a Hull View the current view style is lost
Symptoms: When changing the View Style of a Symbolic View and then recreate
the view, View Style is reset to Default View Style.
Known workaround: Manually change the View Style after recreate of the view.
Solution: Corrected so View Style will remain after a recreation of the view.
70789 142306 Title: Export to dxf - file can't be open in Autocad.
Symptoms: Autocad cannot open an exported drawing.
Known workaround: No known workaround exists.
Solution: Problem with the properties of a drawing.
In version description there is a lot of new line characters after the actual text.
Those new line characters are now removed so Autocad can read the dxf file.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 390 of 517
Product Release Letter
Incident Issue Description
Number Number
70870 142518 Title: Drawing forms location
Symptoms: Request as a system administrator to have the option to choose,
where drawing forms are stored, in PADD or as sdb files in SBD_STD.
Known workaround: No known workaround.
Solution: The Tools/Drawing Form/Save function will now work in analogy with
File/Save:
the drawing form will be stored in PADD if source is stored in PADD, otherwise
not.
71359 144268 Title: After Knuckle panel, Bevel annotate is strange on profile End.
Symptoms: The bevel note on a profile end that belongs to a knuckled panel is
not correct.
Known workaround: No known workaround exists.
Solution: Bevel annotation on profiles ends belonging to a knuckled panel has
now been corrected.
72534 147740 Title: Problem to change the hangul text aspect
Symptoms: Using Hangul font and mode the text, the ratio of the text is canged.
Known workaround: No known workaround exists.
Solution: Corrected so the ration is not changed when moving the text.

Engineering:

Inciden Issue Description


t Number
Number
65165 130967 Title: Tags - Double clicking Diagram icon in list view doesn’t open linked
Diagram and focus on item.
Symptoms: When clicking on Diagram icon in list view doesn’t open linked
Diagram and focus on item.
Known workaround: No known workaround.
Solution: Fixed an issue causing diagrams and 3d objects not opening properly.
137697 Title: It is not possible open list created by macro in batch mode.
Symptoms: It is not possible to open list created by macro in batch mode.
Known workaround: Disable batch mode and open list immediately.
Solution: Issue in Tags application is fixed. It should be noted that it won't be
possible to open a list created by a macro as long as the batch mode is not
disabled ( use BatchMode(False)).
139063 Title: Tags - Reference Browser and edit button state.
Symptoms: Reference Browser edit button is being in the enabled state without
any reference got selected.
Known workaround: No known workaround.
Solution: Reference Browser edit button for Reference Array attributes is being
in the disable state when there is no reference selected on reference list.
139425 Title: Tags - 3D view is not getting generated from the highlight changes window.
Symptoms: 3D view is not getting generated from the highlight changes window.
Known workaround: No known workaround.
Solution: A "3D" contextual menu item is enabled only for Tags lists.
70586 141869 Title: Tags - PMLTAGS / Functions GetCellValue and SetCellColor are not
working when value is empty.
Symptoms: When value is null it is not being highlighted.
Known workaround: No known workaround.
Solution: Changed the behaviour of GetCellValue and SetCellColour functions.
They will now properly nightlight all chosen values.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 391 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
144741, Title: Instrumentation Data Update - Noclaim CYMLNKs.
128647 Symptoms: Linking an object claims the CYMLNK preventing another user
linking the same object.
Known workaround: Unclaim the CYMLNK.
Solution: The deslnk, schlnk and englnk attributes on CYMLNK have been
made noclaim.

Mechanical Equipment Interface:

Incident Defect Description


Number Number
70953 142673 Title: Idealized planar panels exported with one closed loop boundary lines
Symptoms: Idealised planar plates are exported as surface with one closed
boundary loop which leads to problems when the geometry is imported and
meshed in ANSYS Workbench.
Known workaround: No known workaround exists.
Solution: Problem is fixed, curves are now split where the continuity changes
before creating the surface to be exported.

Pipe Fabrication:

Inciden Issue Description


t Number
Number
59816 104628 Title: Cannot check Spool Excess Length.
Symptoms: Cannot check FITT type Spool Excess on Galvanization Tank
Check.
Known workaround: No known workaround.
Solution: Program modified to check FITT type spool excess value.
59825 104648 Title: Copy Spool Break attributes ASFBR and LSFBR when a Pipe or Branch is
copied.
Symptoms: ASFBR/LSFBR attributes always set False after a copy.
Known workaround: Set attributes True manually.
Solution: Change attribute definitions to allow them to be copied.
62633 113856 Title: No information for thread type on the assembly table.
Symptoms: There is no information for thread type on the assembly table.
Known workaround: No known workaround exists.
Solution: Program modified to supply thread type on the assembly table.
59801 116747 Title: Cut Information Table for Elbow
Symptoms: When create pipe spool drawing, there is no cut information table for
elbow
Known workaround: No known workaround.
Solution: Program modified to created cut information table.
67178 129157 Title: Pipe Fabrication Release Error in Marine Drafting.
Symptoms: If a spool is consisting of only one FLANGE, PSVLD is false so the
validation result on the pipe spool drawing is different with pipe fabrication check.
Known workaround: No known workaround.
Solution: The logic to validate spool has supplemented.
68344 135043 Title: One character of item description is lost if two lines are displayed.
Symptoms: One character of item description is lost if two lines are displayed on
the MTO table.
Known workaround: No known workaround.
Solution: Program modified to get description for two more lines on the MTO.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 392 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
68530 135570 Title: Wrong Dimension for a tube which is connected with two COUPling only.
Symptoms: A dimension for a tube which is connected with two coupling only is
wrong.
Known workaround: No known workaround.
Solution: Complemented logic for the tube.
68672, 135987, Title: Form Inconsistency with Blank Flange on the Pipe Fabrication.
69379 138319 Symptoms: If a spool is consisting of only one FLANGE, PSVLD is false the
validation result on the pipe spool drawing is different with pipe fabrication check.
Known workaround: No known workaround.
Solution: The logic to validate spool has been added.
69582 138907 Title: A CUTL value display for all ELBOWS on a pipe sketch
Symptoms: There are unnecessary CUTL values on the drawing.
Known workaround: No known workaround.
Solution: If an elbow needs cutting, the CUTL ( distance between origin and
arrive position) will be shown in the MTO table.
69580, 138908, Title: Views are not in correspondence anymore.
69946 140068 Symptoms: Pipe sketch views are not in correspondence anymore
Known workaround: No known workaround.
Solution:
New option "FIXED_VIEW_DIR" added to keep predefined view directions on the
drawing form. Otherwise, the program will calculate an appropriate view direction
from spool as default.

This option has to be defined on the SHEET(SHEE) of a drawing form as value


of function to keep the predefined view directions as follows.

SAME-SCALE;FOUR_VIEWS_OFF;FIXED_VIEW_DIR"

The value of FUNC can have three options.


FUNC 'SAME-SCALE;FOUR_VIEWS_OFF; NONE_FIXED_VIEW_DIR'

NOTE.) The ordering is important to use the option.

The option is separate by ';'(semi-colon)

1. SAME-SCALE :
This option is used to make same scale views.

2. FOUR_VIEWS_ON:
Show always four views. All four views are displayed even if the spool is
located in one plane.

3. FIXED_VIEW_DIR:
This option is used to preserve predefined view directions on the Drawing
template.
69940 140055 Title: Pipe Spool Drawing Does Not Have the Option for "Select All" and
"Remove All".
Symptoms: There is no option for "Select All" and "Remove All" on the pipe
spool drawing.
Known workaround: Can use "Ctrl+A" and "Del" key.
Solution: Program modified to append the options for "Remove All", "Select All"
and "Unselect All" into the popup menu.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 393 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
70024 140197 Title: Spools without tubes cannot get pipe sketch.
Symptoms: If a spool is consist of only one FLANGE, PSVLD is false the
validation result on the pipe spool drawing is different with pipe fabrication check.
Known workaround: No known workaround.
Solution: The logic to validate spool has been added.
70092 140323 Title: Incorrect BUTT Values on Pipe Spool Drawing.
Symptoms: The Butt values that are included on the Assembly Table are
incorrect
Known workaround: No known workaround.
Solution: Program modified to get the amount of material that needs to be
removed for BUTT value.
70151 140493 Title: Limitation condition of "modifying bend radius" on popup menus.
Symptoms: Popup menu for modifying bend radius cannot be available if
"Apply" button not activated.
Known workaround: No known workaround.
Solution: Program modified to remove condition to active popup menus for
changing bend radius.
70689 142065 Title: Spools without tubes cannot get pipe sketch.
Symptoms: If a spool is consisting of only one FLANGE, PSVLD is false the
validation result on the pipe spool drawing is different with pipe fabrication check.
Known workaround: No known workaround.
Solution: The logic to validate spool has been added.
70915 142616 Title: Cannot plot fabrication iso from outfitting design module.
Symptoms: Cannot plot fabrication iso drawing from outfitting design module.
Known workaround: No known workaround.
Solution: Program modified to assign a PLT file path properly.
70994 142880 Title: Modelling Consistency Check Options Do Not Remembered.
Symptoms: Modelling consistency check options are not maintained the next
time the form is opened.
Known workaround: The user has to choose the option again.
Solution: Program modified to save & restore the check options.
70998 142890 Title: The Pipe Spool Drawing Form Initialisation Improvement.
Symptoms: The pipe spool drawing is not shown if invalid element was
selected.
Known workaround: Select valid element to create a drawing, and then execute
the program again.
Solution: Program modified to show the main form for pipe spool drawing if
invalid element was selected.
71181 143555 Title: Cannot use same keywords which are used for EndPointEntries on the
SpoolInfoTableEntries.
Symptoms: It is not possible to use same keywords which are used for
EndPointEntries on the SpoolInfoTableEntries.
Known workaround: No known workaround.
Solution: The program modified to use same keywords that are used for
EndPointTableEntries on the SpoolInfoTableEntries.
71491 144749 Title: Weld Prefix on Weld Handling.
Symptoms: A weld prefix cannot be used on Weld Handling.
Known workaround: It is possible to assign a weld prefix manually.
Solution: Program modified to use weld prefix.
71489 144751 Title: Joint Prefix and Number for Gasket on Pipe Fabrication Check.
Symptoms: Joint prefix and number for gasket will not be assigned on Pipe
Fabrication Check.
Known workaround: It is possible to assign this information manually.
Solution: Program modified to use Joint Prefix and Joint Number for gasket.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 394 of 517
Product Release Letter

Outfitting:

Incident Issue Description


Number Number
29522 60403 Title: Draft - Choice of background colour for autotagging's exemplar panes.
Symptoms: Default is a blue colour which makes some label types unreadable.
Known workaround: N/A.
Solution: Now attempts to use background colour of current 2-d canvas.
21477 62123 Title: Stepped Plane - plane direction (3D View contra 'Modify' form).
Symptoms: Information on form is unclear.
Known workaround: N/A.
Solution: Form changed to improve clarity of information.
48955 77367 Title: Draft - Error selecting Pipe End Label in Marine Drafting.
Symptoms: PML Error 46,28 reported.
Known workaround: No known workaround.
Solution: Code fixed to avoid error.
55997 97211 Title: Cats & Specs - Default answers in specifications.
Symptoms: The specification form in Paragon allows default values to be set for
specification heading questions but these defaults are not used as answers when
adding components to a specification.
Known workaround: Set answers explicitly using the 'Edit Answers...' panel of
the form.
Solution: If defaults are available, they are used when adding components to a
specification.
58421 99912 Title: database and Data Management - Client Cache Service from Hull &
Outfitting 12.1 is not used by Review database connection.
Symptoms: Data is not cached locally via the Client Cache Service, installed
with Hull & Outfitting 12.1.SP3 or later, when using Review's database
connection.
Known workaround: No known workaround.
Solution: Software fix.
61526 110450 Title: Equipment - VOLM are now a default element for volume collections.
Symptoms: VOLM not added to a volume collection by default.
Known workaround: Specify element type.
Solution: Now fixed.
61810 111465 Title: Design - Description column in CofG form.
Symptoms: No column for description.
Known workaround: No known workaround.
Solution: New column added to form.
65507 123887 Title: Flashing ppoint segments no longer aborted if too many UDET types can
own them.
Symptoms: Problem was that in design/des_feedback.xrc FLSHPK routine
which is responsible for flashing all segments available for picking it aborted
when the local array for all nountypes that can own DDSE elements (and hence
DPSEs for desing points etc) is full. It should have worked with a filled up array
and flashed the segments it new about and also all catalogue ppoints and pline
segments.
Now more likely that array gets filled as UDETs introduced. Only 14 spare slots
available.
Known Workaround: No known workaround.
Solution: Fixed by NOT aborting when array full.
Fixed by increasing local array size from 100 to 1000.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 395 of 517
Product Release Letter
Incident Issue Description
Number Number
66196 138268, Title: Database and Data Management - It is not possible to maintain stamps
125299 when reconfigure sessions is done on a db.
Symptoms: It is not possible to backtrack over a stamp, and deleting a database
deletes its stamps, so it is not currently possible to reconfigure sessions on a
database with stamps and maintain those stamps.
Known workaround: Write appware to record stamps before reconfigure and
reinstate them afterwards.
Solution: Use new FORCE option on BACKTRACK.
70435 142965 Title: Admin - Reconfiguration problem with Database with invalid Unicode
strings and Corrupt Claim Table.
Symptoms: DICE reports a corrupt Claim table. On further investigation, it was
found that this database also contains invalid Unicode strings. Unfortunately in
12.1.SP4, DICE does not check Text attributes for Unicode errors, and
Reconfigurer crashes because of the Unicode errors.
Known workaround: First use DRAFT to fix the 84 invalid UNICODE strings;
then the database can be reconfigured to fix the Claim Table error. (Use
RECONFIGURE SAMEREF) Unfortunately it is necessary to remove the Session
history completely.
Solution: Fix Reconfigurer to handle invalid Unicode strings, so that customers
can fix the Claim table corruption using Reconfigurer. Invalid
attribute value replaced by text '*** Invalid Unicode string'.
71261 143904 Title: Design - Holes exported by MEI export interface.
Symptoms: Holes did not appear in MEI export.
Known workaround: Customise MEI export PML code to add EXPORT HOLES
command.
Solution: EXPORT HOLES command generated automatically from current
holes on/off setting.

12.1.SP4.16

Outfitting:

Incident Issue Description


Number Number
66198 133975 Title: Draft - Unable to export Draft and Isodraft drawings to AVEVA Net
containing TrueType text.
Symptoms: None of the existing drawing export formats supported by PDMS
can be used to send drawings with TrueType text to AVEVA Net.
Known workaround: No known workaround.
Solution: It is now possible to export Draft and Isodraft drawings as SVG files
containing TrueType text. These SVG files, along with the associated hit-files can
then be imported into a new version of AVEVA NET that supports this workflow.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 396 of 517
Product Release Letter

12.1.SP4.15

Planar Hull:

Incident Issue Description


Number Number
65127 123546 Title: Hole Management bug - requested holes in SB plates of SBP panels.
Symptoms: If a Managed Hole is placed on the Starboard part of a symmetrical
panel, the hole is created on both sides.
Known workaround: No known workaround exists.
Solution: Managed Holes will be created only where the hole is requested. Users
are also prevented from changing the symmetry code on Managed Holes.
67101 128694 Title: Scheme is rotated after rerun in hull
Symptoms: When rerun a panel originating from Outfitting, the panel is
somewhat rotated when the schema is rerun.
Known workaround: No known workaround exists.
Solution: Panels will no longer be rotated when rerunning scheme.
67492 130297 Title: Error when approving hole request in deck panels (z = constant) for cable
tray penetrations
Symptoms: When trying to approve the hole request in deck panels using
“HoleManagement…”, is appearing the next error: ‘’Error number: -4”
Known workaround: No known workaround exists.
Solution: Calculation of HPANEL hole position improved to avoid penetrating
vector from being parallel to the HPANEL surface. This avoids error -4 on
Approval.

67172 130349 Title: Wrong symbols and /or bevels in manstiff lists.
Symptoms: Confusing when makeing bevel notes for welded flanges.
Known workaround: No known workaround exists.
Solution: The bevel note now shows the correct side of bevels on planar panel
flange ends, regardless of the flange mould side, i.e. direction.
69363 138254 Title: Name of stiffener in CL differs between ATX and model.
Symptoms: Stiffeners in CL gets different parts names in different applications.
Known workaround: No known workaround exists.
Solution: A more refined check of the exact placement of the stiffener is made to
get the correct name in all places.
70531 141611 Title: Hole Management error occurs for Equipment.
Symptoms: Making Holes for Equipments in Hole Managements on Starboard
side panels fails.
Known workaround: No known workaround exists.
Solution: Corrected so Managed holes are created for Starboard side panels.
70641 142059 Title: Annoying error with stiffener inclination on statement wizard form.
Symptoms: The inclination field in the Statement Wizard is not presenting the
correct value.
Known workaround: Manually modify to the correct value.
Solution: The correct inclination value is presented in the drop down list. If no
inclination is given in a stiffener, the field will be set to blank (i.e. no inclination).

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 397 of 517
Product Release Letter

Hull Structural Design:

Incident Issue Description


Number Number
59067 102517 Title: Strange result from shell expansion.
Symptoms: Strange curves are shown in the ShellX view when an additional
surface is included.
Known workaround: No known workaround exists.
Solution: The problem has been solved so that the curves from the additional
surface is not mixed up with the main surface.

Hull Production:

Incident Issue Description


Number Number
69518 138829 Title: BENDING_INSIDE_PROFILE functionality.
Symptoms: Bending information set when bending radius is less than user-
defined values.
Known workaround: No known work around exists.
Solution: New keyword BENDING_RADIUS_LOW_LIMIT added.(Default 0.0)
Bending radius information is shown for profiles with bending radius greater than
BENDING_RADIUS_LOW_LIMIT and less than BENDING_RADIUS_LIMIT.
70384 141244 Title: Pin-Jig Table & Drawing getting generated withput internal seams
Symptoms: Additional seams are not handled.
Known workaround: Manually add the statement ADD_SEAM into the input file
and rerun the job.
Solution: Corrected so the inner seams are also included in the drawing.

Marine Drafting:

Incident Issue Description


Number Number
59144 102805 Title: Time issue when exchanging from the Drawing Explorer.
Symptoms: Model Exchange via right-click in Drawing Explorer is slower than
Tools -> Model -> Exchange.
Known workaround: No known workaround exists.
Solution: Model Exchange via right-click in Drawing Explorer will have same
performance as when invoked from Tools > Model > Exchange.
61184, 109353, Title: A number of characters is limited in Model Selection form
70077 140290 Symptoms: In the function Input Model, it is only possible to give 26 characters
in the Assembly field.
Known workaround: Use wildcard search and then select from the selection
window.
Solution: The field is modified to accept up to 256 characters in the Assembly
name.
66418 126512 Title: Create a new drawing with a FORM: Both Marine Drafting Form object and
backing sheet lements are listed in the selection dialog.
Symptoms: The list of forms/backing sheets is very long of you list all availble
items.
Known workaround: Use a name filter.
Solution: There is a new default "DRAWING_FORM_BROWSING". By setting
this default to "DRAWING_FORM_BROWSING = NoBackingSheet" you can list
only the Marine Drafting drawing forms and no PDMS backing sheets.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 398 of 517
Product Release Letter
Incident Issue Description
Number Number
66505 127496 Title: VIEW orientation fault.
Symptoms: When a view direction is very close to Z-axis, the pipe is not drawn
correctly.
Known workaround: No known workaround exists.
Solution: Problem with view directions very close to Z-axis now solved.
67660, 131200, Title: Insert assembly module failed using ModelDraw, if assembly name is too
70063 140300 long.
Symptoms: If assembly name's length is greater than 26 and the 27th character
isn't "/",then ModelDraw to insert assembly model will not work.
Known workaround: Use the db-reference string for the assembly instead of the
name.
Solution: Problem with MarApi function ModelDraw vs assemblies fixed.
No need to use DB-reference.
68866 137076 Title: Slicing model view has no affect on Outfit elements for some view types -
confusing for the user.
Symptoms: Hull models will be sliced but not outfitting models - confusing for the
user.
Known workaround: No known workaround.
Solution: There is still no slicing but there will be a warning message in a dialog
box.
69092 137745 Title: Element name when entering what should be exchanged.
Symptoms: In Model Exchange the leading slash "/" must be given.
Known workaround: No known workaround.
Solution: The leading slash may be omitted when user keys in the model name.
69499 138588 Title: Problem to modify drawings in a foriegn database - fail to create a copy in
read-only database.
Symptoms: You fail to create a copy or it is placed in a new "default"
DEPT/REGI created by the system.
Known workaround: Create a another instance of DEPT/REGI setup for this
type in a writable database in the MDB.
Solution: It is now possible to select the drawing type, general drawing for
instance, when your are asked to create a copy.

Schematic 3D Integrator:

Inciden Issue Description


t Number
Number
55674 93584 Title: Comparison at zone level returns different results to individual pipes.
Symptoms: Different reporting of MDS tees on same pipe when compared as
part of zone.
Known workaround: Compare lines individually.
Solution: Comparison at zone and pipe level now consistent.
58236 99187 Title: Wrong info for pipelines on compare.
Symptoms: Two pipes reported matched to one line when should have been
one for one each.
Known workaround: Compare lines individually.
Solution: Lines and pipes now reported matched one for one and bores shown
correctly.
62020 111994 Title: Problem with update data using session units in Integrator.
Symptoms: Copy to 3D does not take account of session units so wrong value
can be written.
Known workaround: Manual update of value.
Solution: Value is set correctly taking into account session units.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 399 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
120277 Title: Integrator not matching pipe with matched end connections.
Symptoms: If the only match condition is on end connections the line is reported
not matched.
Known workaround: None
Solution: Matched end connections are sufficient to report a match on the pipe.
68111 134351 Title: Previously saved comparison report doesn't display correctly.
Symptoms: Actions available in the report can refer to elements no longer
existing giving rise to errors.
Known workaround: Do not update data from a previously saved comparison
report.
Solution: All the actions that update data have been disabled when viewing a
previously saved report.
68581 135688 Title: Accept differences not working correctly for branch.
Symptoms: When the line and pipe are unlinked, accepted differences remain at
branch level.
Known workaround: Reject the accepted differences on branches prior to
unlinking the pipe.
Solution: Accepted differences on the child elements are removed on unlinking
the line and pipe.
139446 Title: Internal Integrator error following disabling matches.
Symptoms: Internal Integrator error when interacting with the compare report.
Known workaround: Close the compare report and compare again.
Solution: The match algorithm has been corrected in a particular case handling
PIPCA elements.

Pipe Fabrication:

Inciden Issue Description


t Number
Number
59813 104627 Title: Check result does not correct on galvanization check.
Symptoms: Check result does not correct on galvanization check.
Known workaround: No known workaround.
Solution: The check logic has supplemented using actual spool volume.
59816 104628 Title: Cannot check Spool Excess Length.
Symptoms: Cannot check FITT type Spool Excess on Galvanization Tank
Check.
Known workaround: No known workaround.
Solution: Program modified to check FITT type spool excess value.
64533 119211 Title: Invalid Flange Rotation Value in the Assembly Table.
Symptoms: If the user assign bolt number on BTSE and make some BLTP
elements from the BTSE, the program will not calculate bolt number properly.
Known workaround: If the user use "Individual bolts" from catalogue, NOFF of
its owner must be assigned to zero as workaround.
Solution: Program modified to get bolt hole properly from flange .
61688 111015 Title: Initialise Modify Weld Form.
Symptoms: If a single weld is selected, the modify weld form does not reflected
about it.
Known workaround: No known workaround.
Solution: Program modified to initialise the form using selected weld.
64269 120446 Title: Create Pipe NC Data as .BEN format.
Symptoms: Cannot create Pipe NC Data as .BEN format.
Known workaround: No known workaround.
Solution: Program modified to create .BEN data files.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 400 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
65900 124368 Title: ATTA components are not included in MTO Table.
Symptoms: MTO table does not have information for ATTAs.
Known workaround: No known workaround.
Solution: Program modified to check volume of ATTA.
If an ATTA has valid volume, it will be included into MTO Table.
67177 129156 Title: Release Error for TEE on Fabrication Check
Symptoms: The "invalid zero direction error" will be happend if reference plane
direction is same as the part arrive direction.
Known workaround: No known workaround.
Solution: The program has modified to get rotation angle where reference plane
direction is same as the part arrive direction.
60727 134623 Title: Location of Check Message File in Pipe Fabrication
Symptoms: Program will only find the check message file in the PDMSEXE
folder
Known workaround: No known workaround.
Solution: Program has been modified to find the file from PDMSDFLTS and
PDMSEXE folder. If PDMSDFLTS folder does not have the file, the program
will find it from PDMSEXE folder.
68571 136350 Title: Problem with some view directions inclined at small angle to the vertical.
Symptoms: Missing design graphics in some views with nearly-vertical view
directions, accompanied by a 'Bad transform value' error message.
Known workaround: None (except changing the view direction).
Solution: Fixed in core code.
69612 138915 Title: Hanging program when collecting deleted thread information on the pipe
ends.
Symptoms: The program will hang if it tries to input a thread end using deleted
COCDES.
Known workaround: No known workaround.
Solution: The program modified to validate a COCDES before creating thread
end.
70059 140261 Title: Too many 3d coordinates on the ISO drawing.
Symptoms: there is too many 3d coordinates on the ISO drawing.
Known workaround: No known workaround.
Solution: Program modified to minimize 3d coordinates on the drawing.
70057 140316 Title: The "Zero direction" error will be shown when validating specific pipe.
Symptoms: The error "An invalid zero direction has been obtained" will be
shown when validating specific pipe.
Known workaround: No known workaround.
Solution: Program modified to get valid direction.
70588 141872 Title: Single View has incorrect orientation.
Symptoms: Some single view has incorrect orientation.
Known workaround: No known workaround.
Solution: Program modified to get correct direction for all single view.
70602 141903 Title: Cannot create a skeches on some spools.
Symptoms: Orientation error will be happened on some spools.
Known workaround: No known workaround.
Solution: Program modified to get valid view directions.
70634 141957 Title: The "Zero direction" error will be shown when validation specific pipe.
Symptoms: The error "An invalid zero direction has been obtained" will be
shown when validation of specific pipe.
Known workaround: No known workaround.
Solution: Program modified to get valid direction.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 401 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
70672 142043 Title: Orientation Error on Specific Pipe Spool (PSPOOL).
Symptoms: Orientation error happens on specific pipe spool (PSPOOL).
Known workaround: No known workaround.
Solution: The program modified to get valid directions.
70976 142814 Title: Pipe Spool Drawing failed Error
Symptoms: The error "An invalid zero direction has been obtained" will be
shown when creating a pipe spool drawing in Pipe Fabrication.
Known workaround: No known worlaround.
Solution: Program modified to get valid direction.
71095 143298 Title: Dabacon Checks Messages on the Config File.
Symptoms: it needs to add all Dabacon check messages which are related to
pipe module into the config file for modeling consistency check.
Known workaround: No known workaround.
Solution: Program modified to have all Dabacon Check Messages which are
related to pipe module.
71146 143428 Title: Some dimensions in projection views are incorrect.
Symptoms: A dimension will be created incorrectly if a dimenion direction is not
parallel with view direction.
Known workaround: No known workarounds.
Solution: Program modified to get valid direction for slanted dimension.
71280 143922 Title: Feed Excess Incorrectly Added.
Symptoms: Pipe Feed Excess is incorrectly added when the pipe is validated for
the second time.
Known workaround: No known workaround.
Solution: Program modifed to assign user feed excess into only valid
component.

Outfitting:

Incident Issue Description


Number Number
68391 135185 Title: Piping - Problem with Component Creation form (Tolerance Settings).
Symptoms: An error occurs when loading the component creation form when
multiple tube tolerances are set.
Known workaround: set the tolerances after loading the component creation
form.
Solution: The form now handles muliple tube tolerances.
68571 136350 Title: Draft - Problem with some view directions inclined at small angle to the
vertical
Symptoms: Missing design graphics in some views with nearly-vertical view
directions, accompanied by a 'Bad transform value' error message.
Known workaround: None (except changing the view direction).
Solution: Fixed in core code.
69069 137373 Title: Database and Data Management - Application can be slow to start if Model
Changes addin was used.
Symptoms: Application can be slow to start if Model Changes addin was shown
previously on a project with a large total number of database sessions.
Known workaround: Close the Model Changes addin before closing the
application.
Solution: Model Changes addin his now alwasy hidden on application start; an
upper-bound on the time taken to open the addin has been implemented.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 402 of 517
Product Release Letter
Incident Issue Description
Number Number
69517 138676 Title: Isodraft - Bolts shown on both isometrics when Flanges either side of Valve
are in different Pipes.
Symptoms: Bolts shown on both isometrics when Flanges either side of Valve
are in different Pipes.
Known workaround: No known workaround.
Solution: Show Bolts with downstream Flange.
65450 140229 Title: Reporting - Unable to run Quick reports.
Symptoms: Message; "Could not create file".
Known workaround: Make sure you can write to current directory.
Solution: Temporary File now correctly written to PDMSWK directory.
69577 140343 Title: Piping - The component creation form sometimes throws an invalid
direction error when trying to align components.
Symptoms: An invalid zero direction error message appears when creating
elbows and bends.
Known workaround: No workaround necessary as it makes no difference to the
model.
Solution: The direction checking code now works correctly.
140781 Title: Isodraft - Isodraft crash if Comparison Date specified for an isometric
containing Bolts and Weights shown in Material List.
Symptoms: Isodraft crash if Comparison Date specified.
Known workaround: No known workaround.
Solution: Do not check attribute change for a Bolt weight.
142040 Title: Isodraft - PDMS-VPRM Gateway Bolt substitution does not work when
erm_ref_uda = :ERMREF.
Symptoms: VPRM/ERM Bolts part numbers not shown on isometric
when erm_ref_uda = :ERMREF.
Known workaround: Define and populate DTAB UDAs.
Solution: Default to Spref if Bolt UDAs not present.

12.1.SP4.14

Database and Data Management:

Incident Issue Description


Number Number
62699 114139 Title: Object reference not set to an instance of an object
Symptoms: dbprompt crashes.
Known workaround: This is due to having an element with an empty name
created. Renaming or removing the element will make dbprompt start working.
Solution: dbprompt is updated to deal with this situation.
67571 130827 Title: dbprompt crashes with message Object reference not set to an instance.
Symptoms: dbprompt crashes.
Known workaround: This is due to having an element with an empty name
created. Renaming or removing the element will make dbprompt start working
Solution: dbprompt is updated to deal with this situation.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 403 of 517
Product Release Letter

Initial Design:

Incident Issue Description


Number Number
54930 91845 Title: Surfaces as boundaries are now written to boundary part of RSO in XML
file.
Symptoms: If a surface were referenced as boundary of RSO they were not
written to XML file.
Known workaround: No known workaround.
Solution: The code for identifying surfaces as boundaries were missing in the
RSO export, now added.
66479 126503 Title: Incorrect transformation when using alternative coordinate.
Symptoms: When storing coordinate data and using alternative coordinate
system settings the stored coordinates were incorrect.
Solution: Corrected the code that calculates the transformation from alternative
coordinate system back to original transformation used internally.
66957 127957 Title: Table row style definition in themes.xml file not recognised.
Symptoms: All table rows got the same format, not possible to customise tables
as in earlier versions of Hydrostatics & Hydrodynamics.
Known workaround: No known workaround exists.
Solution: Executable have been updated to handle the tableRowStyle tag
properly.
68788 136254 Title: Seakeeping crashes when calculating Sway Velocity in long term
calculations.
Symptoms: Application crashes.
Solution: Code changed.

Planar Hull:

Incident Issue Description


Number Number
47144 73572 Title: Autopos reflected panel
Symptoms: In resulted .lst file after running Autopos, lines for panels built in PS
and valid in SB are presented twice.
Known workaround: Manually remove the doubled line.
Solution: Lines for panels built in PS and valid in SB will be presented only one
time.
48017 74536, Title: The shape of "Indicate" button is abnormal in Fillet curve wizard.
104197 Symptoms: The text in the Indicate button in the Fillet Curve Wizard is not
readable.
Known workaround: No known workaround exists.
Solution: The text is adjusted to be readable inside the iconbox.
52013 85967 Title: Named Cutout problem.
Symptoms: Adding a Named Cutout to the cutout selection drawing, the cutout is
not displayed in the preview window in the Statement Wizard and the collar plates
(clips) that belongs to the cutout is not correctly handled.
Known workaround: No known workaround exists.
Solution: Corrected so the preview window of the cutout is updated and the
collar plates are correctly handled.
64322 118406 Title: New 'tidy' subfolders are not appearing when elements are generated
Symptoms: Running the Finite Element Idealiser, the FEM images are not
automatically populated to the Design Explorer.
Known workaround: Crop the FEMWLD node and then expand it again.
Solution: FEMIMG will automatically be populated into the Design Explorer.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 404 of 517
Product Release Letter
Incident Issue Description
Number Number
64764 120769 Title: _TBhook_AutoPanelName.py No autonaming for RSO-Location possible
Symptoms: If a panel location is a referenced object (e.g. RSO), then the
autonaming hook will not give correct name suggestion.
Known workaround: Manually change the name before the panel is created.
Solution: Corrected so the hook will also handle when the panel location is a
referenced object.
66704 127068 Title: Hole Management - error when copy panel.
Symptoms: A planar panel contains a managed hole. Then - this panel is copied
using "panel copy" function". The managed hole is copied and stored together
with a new panel, which leads to corruption of Hole Management, as there are 2
managed holes in different panels, that have the same hole name and
association.
Known workaround: Before copying the panel, disconnect the managed hole,
copy the panel and then add the managed hole once again to the original panel.
In thw copy, remove the unwanted hole.
Solution: Fixed in the way that managed holes are not copied by the Panel Copy
function. If there should be another hole in the new panel, there needs to be a
new request for a managed hole.
66928 127814 Title: The panel has a gap because the thickness values are inputted to Plus and
Minus.
Symptoms: Abutting panels with a fixed bevel and the material on both sides of
the mould plane gets an unexpected gap towards the abutted panel.
Known workaround: No known workaround exists.
Solution: The problem has been solved so that there is no gap with material on
both sides of the mould line.
67231 129646 Title: HPRHOL cannot be created in a HSTIFF of a knuckled panel.
Symptoms: Holes created in a stiffener that belongs to a knuckled panel does
not show any HPRHOLE element beneath the owning HSTIFF element.
Known workaround: No known workaround exists.
Solution: Stiffeners on knuckled panels now also display their hole, notch and
cutout elements.
67280 129704 Title: Panel boundary does not stop on the stiffener(Profile Along).
Symptoms: Referring a shell profile in a Planar Panel boundary, using option
Profile Along is not following the profile but instead penetrating the profile flange.
Known workaround: Instead of refering the profile, use Line option.
Solution: Corrected so the boundary will stop at the profile flange as expected.
67172 130349 Title: Wrong symbols and /or bevels in manstiff lists.
Symptoms: Confusing when making bevel notes for welded flanges.
Known workaround: No known workaround exists.
Solution: The bevel note now shows the correct side of bevels on planar panel
flange ends, regardless of the flange mould side, i.e. direction.
67811 132293 Title: Autotag in hull scheme TAG like 1 all components in group
Symptoms: When handling a group of stiffeners in the Statement Wizard, the
stiffeners all gets the same TAG if Auto Tag is clicked.
Known workaround: Manually change in the schema to unique tag numbers.
Solution: Fixed so all stiffeners in the group will get unique tag numbers.
67856 132894 Title: Problem for the knuckle panel of startboard side with the specific
slanted angle to disappear.
Symptoms: For a symmetrical knuckled panel, the starboard side is removed by
the system in the symbolic view.
Known workaround: No known workaround exists.
Solution: Corrected so the symbolic view is also correct for the starboard side
image of the knuckled panel.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 405 of 517
Product Release Letter
Incident Issue Description
Number Number
67860 132907 Title: Problem for SI2 to disappear into Bracket statement after defines the
position of the bracket(syx3).
Symptoms: If modify or panel Scheme Editor is opened after generating bracket
by syntax3 with SI2, the SI2 information disappered.
Known workaround: Manually add SI2 in the schema.
Solution: Corrected so SI2 will remain if it has been given.
68210 134671 Title: If SID=*,TOP is given, Point Position of Profile cross is wrong with slant
flange.
Symptoms: The topology point in the flange is not correctly placed.
Known workaround: No known workaround exists.
Solution: The topology point will be correctly placed also on slanted flanges.
68212 134675 Title: The GPS of Clip can not deleted via GUI on Hull Design.
Symptoms: When modifying cutouts whith their belonging collar plates (clips),
the General purpos Strings (GPS) is not possible to modify/delete.
Known workaround: Modify/delete in the schema.
Solution: Possibillity to modify/delete GPS in the Statement Wizard for clips has
been fixed.
68216 134764 Title: Pillar creation failed in a cross panell view.
Symptoms: Trying to indicate pillar end points in a cross section view fails.
Known workaround: Indicate in a non cross section view.
Solution: Corrected so indication can be done in any view.
68305 134923 Title: Deletion of MOGWLD's components from Explorer for normal users.
Symptoms: It is possible to delete components from the MOGWLD with the
Right Click command.
Known workaround: No known workaround exists.
Solution: Fixed so the components in MOGWLD is not deletable with the Right
Click command.
68598 135727 Title: Split STI function.
Symptoms: Giving more than one line to the Split Stiffener function will only
handle the first given line to split the stiffener.
Known workaround: Split the stiffeners with one line at the time.
Solution: Corrected so that multiple lines can be given to split stiffeners in a
single operation.
69572 138831 Title: Problem not to define M1 value to the section contour for a penetrating
object.
Symptoms: Making holes for penetrating objects does not handle the
keyword/value M1 in the Statement Wizard.
Known workaround: Manually handle the M1 keyword in the schema file.
Solution: The problem has been solved so that the M1 value for hole of
penetrating object can be set by the Statement Wizard.

Curved Hull:

Incident Issue Description


Number Number
63928 119206 Title: Curved panel view can’t be created.
Symptoms: Creating a curved Panel view gives no view and no message of why
the view is not created.
Known workaround: No known workaround exists.
Solution: Corrected so the view will be created.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 406 of 517
Product Release Letter
Incident Issue Description
Number Number
67506 131225 Title: System has been terminated unexpectedly during generating Body plan
view.
Symptoms: When making a Body Plan View, the system aborts if there are Shell
Profiles defined with 2 points and axis.
Known workaround: No known workaround exists.
Solution: Corrected so the Shell Profiles defined with 2 points and axis will be
correctly handled in Body Plan View.
68296 134903 Title: The Hole&Marking position is wrong in ShellProfile.
Symptoms: Some marking lines are outside the shell profile.
Known workaround: No known workaround exists
Solution: Corrected so the hole and marking is in the correct place.
68408 135224 Title: In Bodyplan, No applied Seam blocklimit.
Symptoms: Seams defined as Block limits are hard to see in a Bodyplan view.
Known workaround: Manually identify the seams and change linetype.
Solution: Block Limit seams are drawn as Solid Wide automatically.
68413 135231 Title: Problem for MarShellXViewOptions not to properly work Get for a given
view by ViewCurvedModify.
Symptoms: Function not working to get from existing views.
Known workaround: No known workaround exists.
Solution: Corrected so function work to get from existing views.
69770 139341 Title: When set to YES for Shell Stiffener, It is go outside from Surface.
Symptoms: when defining Auto bevel on Starboard side Shell Stiffener, the
section of the stiffener is outside the surface.
Known workaround: No known workaround exists.
Solution: The problem has been solved so the profile does not go outside the
surface when Autobevel is set to YES.

Hull Structural Design:

Incident Issue Description


Number Number
54930 91845 Title: Surfaces as boundaries are now written to boundary part of RSO in XML
file.
Symptoms: If surfaces were referenced as boundary of RSO they were not
written to XML file.
Known workaround: None.
Solution: The code for identifying surfaces as boundaries were missing in the
RSO export, now added.
62788 114259 Title: Functional panel created from RSO is not created and stored in block.
Symptoms: Functional panel is not saved dispite there are writeable default
block available (JUMBO).
Known workaround: No known workaround exists.
Solution: If a panel is candidate for more than one block, the first writable block
will be used to save the panel in.
67201 131059 Title: Managed Holes Bug in FEM idealised blocks.
Symptoms: Having Managed Holes in the model and then making an Idealized
model, the managed hole gets corrupted.
Known workaround: No known workaround exists.
Solution: The idealized model will handle the hole but remove the managed flag
in the idealized model.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 407 of 517
Product Release Letter

Space Management:

Incident Issue Description


Number Number
57942 98299 Title: Curved panel Subtracted for Painting area
Symptoms: The Painting area of the shell profiles to be connected to the Curved
panel is not subtracted correctly.
Known workaround: No known workaround exists.
Solution: Subtract is added in the same way as for planar panels.
67275 129666 Title: Space Management Paint Calculation report to have Functional
Description coloumn.
Symptoms: Enhancement request to add Functional Description to the resulting
csv file.
Known workaround: NO known workaround.
Solution: Functional Description added to the csv file.

Hull Production:

Incident Issue Description


Number Number
63282 116804 Title: Two negative radius on edge-not transferred the second one.
Symptoms: If there are two more negative radius on the same edge, then the
second radius will be not related anymore after splitting.
Known workaround: No known workaround exists.
Solution: Fixed so that the radius will remain.
117221 Title: App crash when Hullmark font is selected after storing it.
For further description please see section Enhancements above.
65474 122750 Title: FUN syntax is not working in Auto position number
Symptoms: The Functional description (FUN) is not included in the input file
created for Autopos.
Known workaround: Manually add the /FUN=<no> into the input file before
execution.
Solution: Corrected so also the /FUN is automatically added to the Autopos input
file.
65200 121848 Title: The flange marking direction of stiffener is reversed on Knuckled panel.
Symptoms: The marking direction of the flange is not correct on stiffeners on
knuckled panels.
Known workaround: No known workaround exists.
Solution: Corrected so the marking direction is correct.
65201 121849 Title: The marking of stiffener is disappear on Knuckled panel.
Symptoms: The marking of stiffeners on knuckled panels is missing after
ppanparts.
Known workaround: No known workaround exists.
Solution: Corrected so the marking of stiffeners is correct on knuckled panels.
65202 121850 Title: The marking height of stiffener is different from Model info on Knuckled
panel.
Symptoms: The marking height of stiffener is different from Model info on
Knuckled panel. Before making the knuckled panel, the marking on the sub-
panels are correct.
Known workaround: No known workaround exists.
Solution: Corrected so marking hight is on the plate parts.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 408 of 517
Product Release Letter
Incident Issue Description
Number Number
65474 122750 Title: FUN syntax is not working in Auto position number.
Symptoms: The Functional description (FUN) is not included in the input file
created for Autopos.
Known workaround: Manually add the /FUN=<no> into the input file before
execution.
Solution: Corrected so also the /FUN is automatically added to the Autopos input
file.
66643 126934 Title: Bevel Type 25 Wrong Cutting length in PPI
Symptoms: When giving an angle (A) in the bevel statement using a bevel type
25 (fillet version of V-joint), the resulting part is too small.
Known workaround: Possible workaround is to add excess to the limit but this
must be manually calculated each time.
Solution: Corrected so the system automatically calculates the
extension/reduction of the plate automatically.
66774 127400 Title: Bending templates is not working.(fatal error).
Symptoms: Calculating Bending Templates for a curved Panel with Excess
defined on a plate limit, before (or after) two combined plate limits, aborts the
system.
Known workaround: No known workaround exists.
Solution: Corrected so excess information will be handled correctly and the
system will not abort.
66819 127504 Title: Interactive jigs are not created.
Symptoms: System reports error when trying to create jigs for two planar panels.
Known workaround: No known workaround exists.
Solution: Corrected so the jigs are created for two planar panels.
67281 129706 Title: Auto bevel is strange on Metal touch(variable angle.)
Symptoms: This problem was not possible to verify but errors in Plate Nesting
has been corrected.
Solution: When simplifying mark geometry created with help of STIMARKHOOK
and VMARK, the markings will be correct (PLCM).
133150 Title: Making a correction to the Hull View form does not work unless closing the
drawing
Symptoms: Attempting to create a Symbolic Hull View with incorrect values will
get an "Empty resulting view" message (expected). However, regardless what
correct changes is made to the form, it is not possible to get a view in this
drawing after getting this warning.
Known workaround: Close the drawing and open it again and do the Hull
Symbolic View with correct values.
Solution: Corrected so a new correct Hull Symbolic View can be made without
closing the drawing.
68739 136141 Title: The Marking information is disappear in the production data.
Symptoms: Added marking data is not included in the plate parts. Also an error
11049 is written in the log file.
Known workaround: No known workaround exists.
Solution: Corrected so markinglines added in the planar panel will also be
included in the resulting plate parts.

Hull Weld Planning:

Incident Issue Description


Number Number
58413 117224 Title: Wrong position of the weld objects at Double-T-bars.
Symptoms: The weld for a I-bar is placed at the wrong position.
Known workaround: No known workaround exists
Solution: Weld for I-bars are now created and presented correctly.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 409 of 517
Product Release Letter
Incident Issue Description
Number Number
67267 129649 Title: Weld lines are created on the opposite side.
Symptoms: Weld line between a bracket and profile on starboard side may be
located on the wrong side.
Known workaround: No known workaround exists.
Solution: Corrected so the weld line is appearing at the correct location.
67268 129650 Title: Weld lines are not created correctly for the end of the stiffener and face.
Symptoms: Profile abutting another profile on the same planar panel mey be
missing weld line for the face plate connection.
Known workaround: No known workaround exists.
Solution: Corrected so the weld line for the face plate connection is calculated.
67271 129652 Title: Fillet weld is created as a joint weld.
Symptoms: Weld line for a bracket is inside the material.
Known workaround: No known workaround exists.
Solution: Corrected. The weld line is calculated on the correct side of the
bracket.
67330 129768 Title: Unnecessary weld line is created on the block joint.
Symptoms: Weld line created from a block edge along a twisted shell stiffener
that belongs to another block.
Known workaround: No known workaround exists.
Solution: Corrected so the unnecessary weld line is omitted.
67331 129770 Title: Unnecessary weld line is created on the bracket.
Symptoms: An unnecessary weld line on bracket defined in syntax 2 added.
Known workaround: No known workaround exists.
Solution: The weld line is omitted.
67332 129771 Title: The weld line for end of the bracket is missing.
Symptoms: Weld line at the end of a bracket defined with syntax 2 is missing.
Known workaround: No known workaround exists.
Solution: The missing weld line is correctly calculated.
67753 131377 Title: Weld lines for all items which related with a Curved Panel are not created.
Symptoms: Weld lines for joint of the adjacent blocks on the shell plate are not
created.
Known workaround: No known workaround exists.
Solution: Corrected so the weld line is created.

Hull Nesting:

Incident Issue Description


Number Number
61262 110360 Title: No GSD in PLCM nesting
Symptoms: Having set GSD shape as LINE, the GSD marking information is
missing in the generic files from PLCM.
Known workaround: No known workaround exists.
Solution: Corrected so the GSD marking lines will be present in the generic files.
66468 126408 Title: BurnerID attribute for individual assembly nestings is unset.
Symptoms: Attribute BurnerID is not set for the individual nestings when making
assembly nestings.
Known workaround: No known workaround exists.
Solution: Corrected so the attribute is correctly set for the individual nestings.
66975 128058 Title: Autoposition numbers do not work correct.
Symptoms: Changing the default AUTO_POSNO_PART to 1, the position
numbers are very big in left down sketch corner.
Known workaround: Manually move and change the position numbers.
Solution: Corrected so the position numbers gets correct size and placement.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 410 of 517
Product Release Letter
Incident Issue Description
Number Number
67373 129883 Title: Nesting crashes after renaming.
Symptoms: When renaming a nesting, the system gives error 304 and then
aborts if the nesting sketch already exists but no nesting with the new name
exists.
Known workaround: Before renaming the nest, delete the nesting sketch in File
-> Database menu.
Solution: Corrected so if no nest exists, the nesting sketch is automatically
overwritten by the new copy.
67381 129897 Title: Nesting, not possible to create plate parts, works fine in SP3.
Symptoms: Fatal error occurs when trying to create plate parts from drawings
that was imported (DXF).
Known workaround: No known workaround exists.
Solution: Corrected so the parts can be correctly created.
67585, 130844, Title: Optimized rawplate > Looping when THICK_CHECK=1
68974 137171 Symptoms: In a given nest, with e.g. part thickness is 16 mm and raw plate
thickness is 14 mm and the min/max thickness differences are +- 0.1 mm the
system hang. This means that the thickness check would make it impossible to
nest the part. The problem is only in these situations.
Known workaround: No known workaround exists.
Solution: Corrected. The system will continue and make the calculation for the
plate.
67579 130899 Title: The function of "AUTO_BEVEL_INFO=Yes" does not work properly
Symptoms: The bevel symbol is placed outside the nesting if the default variable
AUTO_BEVEL_INFO is set to Yes.
Known workaround: Manually move the symbol to the correct place.
Solution: Corrected so the bevel symbol is placed correctly.
69040 138782 Title: In Burning Sketch reference plane marking text not coming Automatically.
Symptoms: The names of reference planes are missing in the burning sketch.
Known workaround: The names can be added manually.
Solution: The names will be added automatically when the burning sketch form
is inserted.
69777 139421 Title: PLCM crashes with setting labels for POSNOs automatically.
Symptoms: The program crashes when labelled position numbers are added
automatically.
Known workaround: No known work around exist.
Solution: The crash has been corrected.
69780 139432 Title: Burner ID Sort.
Symptoms: The Burner ID is always listed in alphabtical order.
Known workaround: No known workaround exists.
Solution: Modified so the Burner ID is possible to sort both on ID and on
Comment field.

Marine Drafting:

Incident Issue Description


Number Number
48342, 75562, Title: Number pad is not working when selecting a subpicture level.
69583 138906 Symptoms: Trying to use the numberpad (no 1 to 3) to select sub-picture level is
not working.
Known workaround: Use keyboard number or indicate number on screen.
Solution: Corrected so key 1 to 3 on the numberpad is recognized.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 411 of 517
Product Release Letter
Incident Issue Description
Number Number
58269 99284 Title: Sheet size should be same with Drawing Form.
Symptoms: The sheet size is not the same as the drawing form when starting a
new drawing.
Known workaround: No known workaround exists.
Solution: Corrected so the sheet size is correctly initiated to the drawing form
size.
58574 100792 Title: The result of Delete_Dimension after subpicture regroup is different
between 12.0.SP6 and 12.1.SP3
Symptoms: Making a regroup of a sub-picture containing dimensionings, the
dimensioning component is not recognized as a dimension any more which
makes it impossible to delete as a dimension.
Known workaround: Delete the unrecognized dimension either as a subpicture
or by geometry.
Solution: Corrected so that the regrouped dimension will now keep it's identity
(but still lose its associativity, as before). In case not all parts of the dimension
geometry are regrouped, the original dimension will (as before) be retained (after
a subsequent "update anno").
64001 117435 Title: “Doffset” minus value is not applied to a dimension when a drawing is
opened in Marine Draft.
Symptoms: The attribute "Doffset" is not considered when it is a negative value.
Known workaround: No known workaround exists
Solution: A negative “Doffset” value is now interpreted correctly in a linear
dimension.
65324, 122441, Title: DEF_POINT_MODE doesn't work properly
68554 135557 Symptoms: Variable DEF_POINT_MODE doesn't work in Marine Drafting. When
DEF_POINT_MODE is set to e.g. 23 (Event Point), it still return a Node Point
while using 2D Linear Dimension.
Known workaround: No known workaround exists. Just manual change when
point mode is to be changed.
Solution: A new Drafting default keyword DIM_DEF_2DPOINT_MODE has been
introduced. This one will be used as "initial 2D point definition mode" (instead of
hardcoded "Node") when entering the following dimensioning functions: .
* 2D Linear
* 2D Distance
* 3D Distance To Plane – Leader
66352 126198 Title: Update Autotagging only works if CE is LAYE or a VIEW
Symptoms: If CE is something else then you get a message error: '(64,80) This
command is not valid at SLAB elements'
Known workaround: NO (Only the obvious action of making the correct LAYE or
VIEW the current )element
Solution: Update autotagging has been improved and it is now possible to
select the view that should be updated (ALL is avaiable).
67265 131205 Title: Automatic Blanking of Dimensions prevents PDF Creation.
Symptoms: Blanking is blanking out too much.
Known workaround: Disable the rendering of blanking, by setting the Drafting
default keyword RENDER_AUTO_BLANKING to "No".
Solution: Fixed so blanking works as expected when creating PDF documents.
68805 136372 Title: Model view change projection - Fatal error.
Symptoms: Function Tools->Model View->Change projection sometimes cause
a fatal error.
Known workaround: No known workaround exists.
Solution: Corrected so the projection will change without having the system to
abort.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 412 of 517
Product Release Letter
Incident Issue Description
Number Number
68959 137077 Title: Unable to change the Outfitting slice depth for a Hull View.
Symptoms: Changing the depth of a symbolic view has no effect on outfitting
models that are added to the view.
Known workaround: No known workaround exists.
Solution: Corrected so when changing the depth, Outfitting models are also
affected.
69485 138541 Title: Open Drawring: Wildcard search does not work for user defined drawing
types if drafting default keyword IGNORE_MARPTYPE_FOR_USERDEF is set to
YES.
Symptoms: All drawings for the department for these drawing types are listed.
Solution: Wildcard search will now work as expected.
69585 139179 Title: Making a correction to the Hull View form does not work unless closing the
drawing.
Symptoms: Attempting to create a Symbolic Hull View with incorrect values will
get an "Empty resulting view" message (expected). However, regardless what
correct changes is made to the form, it is not possible to get a view in this
drawing after getting this warning.
Known workaround: Close the drawig and open it again and do the Hull
Symbolic View with correct values.
Solution: Corrected so a new correct Hull Symbolic View can be made without
closing the drawing.
69747 139303 Title: "Insert to Symbolic view" performance slower than SP3.x and SP4.0 in
AM12.1.SP4-Marine Drafting.
Symptoms: Adding Outfitting items to a Symbolic View is conciderable slower in
12.1.SP4 than in 12.1.SP3 and the quantity in the drawlist is higher.
Known workaround: No known workaround exists.
Solution: Corrected so that only those outfitting elements that exists in the
volume of symbolic view are added to id list.

Engineering:

Incident Issue Description


Number Number
97538 Title: Tags - An Unhandled exception error gets displayed when user tries to
modify the value of filtered elements based on created attribute filter.
Symptoms: An Unhandled exception error gets displayed when user tries to
modify the value of filtered elements based on created attribute filter.
Known workaround: None.
Solution: When element does not match filter criteria then it just disappears.
111989 Title: Tags - Last applied operator(AND/OR) in user filter gets set for
all configurations.
Symptoms: The last applied operator is applied for all the elements.
Solution: Admin Filter is applied only to the configuration it is defined for.
139495 Title: Compare/Update: "Manage configuration.n" (Compare/Update) in the Tags
module wants to open file without rights
Symptoms: Issue with access rights to compareupdateconfiguration.xml
Known workaround: No known workaround.
Solution:Resolved access right issue for compareupdateconfiguration.xml
139656 Title: Tags - Highlight Changes doesn't show STAMP on a GLOBAL project.
Symptoms: In SVG Highlighting existing stamps are not displayed on GLOBAL
project.
Known workaround: No known workaround.
Solution: Now user can see STAMPs on GLOBAL project.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 413 of 517
Product Release Letter

Mechanical Equipment Interface:

Incident Defect Description


Number Number
69241 137891 Title: MEI Export - Does not support UNC file paths.
Symptoms: When trying to export to a UNC (Universal Naming Convention) file
path, the result is empty. If exprting to a local path, the result is fine.
Known workaround: Export to local path.
Solution: Fixed so UNC path will be properly handled.

Pipe Fabrication:

Inciden Issue Description


t Number
Number
57762 97664 Title: ADD CE on the Assign Bend Machine.
Symptoms: It cannot add CE on the list.
Known workaround: None
Solution: Program modified to add CE.
67953 134013 Title: Pipe which made bore unit as inch cannot be validated.
Symptoms: Pipes cannot be validated if pipe is created when Bore unit is Inch.
Solution: Program modified to get bore properly.
69567 138819 Title: Pipe which made bore unit as inch cannot be validated.
Symptoms: Pipes cannot be validated if pipe is created when Bore unit is Inch.
Known workaround: No known workaround.
Solution: Program modified to get bore properly.
69614 138889 Title: The bend radius in the Assign Bending Machine is incorrect.
Symptoms: The initial values for the bend radius that are shown when the form
is initialised are wrong.
Known workaround: No known workaround.
Solution: Program modified to show bend radius correctly.
69855 139802 Title: View Orientations are Incorrect.
Symptoms: The View orientations for the four view pipe spool drawing are
incorrect.
The views do not relate to on another.
Known workaround: No known workaround.
Solution: Program is modifed to get proper view direction.
69856 139803 Title: Change Bend Radius by Picking.
Symptoms: Cannot Change Bend Radius by Picking.
Known workaround: No known workaround.
Solution: Program modified to change bend radius by Picking.
70087 140306 Title: Exception Error Occur in the Fabrication Check.
Symptoms: Exception Error Occur when program get a minimum feed excess
from not suitable machine.
Known workaround: No known workaround.
Solution: Program modified to get minimum feed excess from valid machine.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 414 of 517
Product Release Letter

Outfitting:

Incident Issue Description


Number Number
47031, 44605, Title: Isodraft - Isodraft options producing Inter-DB macros cause crash after
46740 72710, savework in Design.
72749 Symptoms: Design crashes on savework when an isometric has been produced
using options MARK DETAIL ON or MARK REVISION ON or REPEATABILITY
ON.
Known workaround: Produce isometrics from Isodraft for these options.
Solution: Update database directly from Design for update of REV and DETA
attributes if DB is writeable. Produce macros for Split ATTAs and read-only
databases from Design.
56181 94399 Title: Improve test for Extract in Claim form to avoid problems with Database
naming conventions.
Symptoms: Reported problems with Extracts which were not Working extracts,
due to their naming conventions for standard Extracts. The form sometimes
reports an error when running claims on a Multi-write Master DB, because it
incorrectly runs "EXTRACT CLAIM" commands on the Master! Fortunately
Extract Claim Hierarchy commands don't report any errors!
Known workaround: Use 'Claim Current Element hierarchy' (or similar) which
doesn't report any errors, rather than 'Claim Current Element Only' which does.
Avoid naming conventions for Databases which contain the string '_EX'
Solution: Form recoded to use a simple attribute test for Extracts, rather than
the convoluted test used at present.
66583 126787 Title: Piping - Changes to the way MDS ATTAs are handled
Symptoms: Adding a MDS support to a pipe splits pipe pieces
Known workaround: None
Solution: This is no longer the case.
NOTE: Before this fix, adding an ATTA with SPKBRK true would break a pipe
piece into shorter ones unconditionally. This may be generally correct, but not in
the case of an ATTA added purely for the purposes of MDS as part of a support.
(MDS ATTAs created with the MDS application have the SPEC of their SPREF
equal to /MDS or /MDF.)

With this fix applied, such an ATTA will be ignored in pipe piece generation by
Production Checks. Any spools generated before the fix may have to be redone,
as they will contain more pipe pieces than necessary. Where an ATTA is
deliberately introduced in order to break a long pipe piece into smaller pieces,
that will still work, as long as its SPREF does not contain the strings '/MDS' or
'/MDF'.
69528 138711 Title: Isodraft - Weld Numbering not re-initialised for isometrics produced from
a detail list.
Symptoms: Weld Numbering is continued from previous isometric in detail list.
Known workaround: Produce isometrics individually rather than from a detail
list.
Solution: Re-initialise weld numbering count when processing 2 pipes in the
same Transfer File (from a detail list).
69714 139170 Title: Plot CE uses ANET-RVM2XGL license when Aveva net files are
unchecked.
Symptoms: Potential nnecessary license claims.
Known workaround: No known workaround.
Solution: Altered license check on plot CE form to only operate when checkbox
is selected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 415 of 517
Product Release Letter
Incident Issue Description
Number Number
69722 139188 Title: Isodraft - PSPOOL isometric does not show tube following ATTA.
Symptoms: Incorrect dimensions on PSPOOL isometric.
Known workaround: Set SPKBRK TRUE for ATTA
Solution: Include ATTA in BELRFA attribute of PPSOOL irrespective of its
SHOP setting - as per Spooler. Isodraft to write the ATTA and the tube following
it to the Transfer File irrespective of its SPKBRK setting.
70398 141253 Title: Design - Positioning problem with non inline piping & hanger elements.
Symptoms: POS command gives wrong results at 12.1.SP1 Fix 13.
Known workaround: Use fix 12.
Solution: Corrected.

12.1.SP4.13

Planar Hull:

Incident Issue Description


Number Number
68270 134823 Title: The figure of cutout for T-bar is incorrect on AM12.1.SP4.
Symptoms: The shape of the generated cutout is erroneous.
Known workaround: No known work-around exists.
Solution: The shape of the generated cutout is OK.

Hull Structural Design:

Inciden Issue Description


t Number
Number
67820 132895 Title: Open Drawing dialog: the name field is cleared when you change drawing
type.
Symptoms: The name field is cleared when you change drawing type.
Known workaround: Re-enter the name.
Solution: The name field is now unchanged when you change drawing type.

Hull Production:

Incident Issue Description


Number Number
68769 136222 Title: Shape defect of PS-panel(Gen.File) on SBP-panel
Symptoms: Create the parts for the symmetrical panel in the test case
(ppanparts) and then run the plate interface. The geometry in resulting generic
files contain different number of segments.
Known workaround: The excess on the seam (LEX=-2) causes the problem with
zero segments in some geometries. If removed, the result is OK.
Solution: After the correction no zero segments will be created.
69250 138018 Title: Bevel in Holes not available
Symptoms: Bevel in holes missing in the Nesting burning sketch
Known workaround: The bevel in holes can be added manually
Solution: The bevel information in holes will automatically be added when the
form is added to the burning sketch.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 416 of 517
Product Release Letter
Incident Issue Description
Number Number
69323 138145 Title: Problem not to symmetrically generate the plate parts of symmetrical panel
brackets.
Symptoms: Panel brackets on a symmetrical panel are identical on both sides
after ppanparts
Solution: ppanparts needs to be re-run for symmetrical panels containing panel
brackets.

Hull Nesting:

Incident Issue Description


Number Number
67573 130806 Title: Automatic Production information in burning sketch is not coming at proper
location.
Symptoms: The automatic production texts in the Plate Nesting Sketch is not
positioned correctly.
Known workaround: Manually replace the text to the proper location
New keywords will work from next hot fix 4.13.
Until then customer should modify keywords below before nest sketch creation:
DIST_TEXT_PART =10 - the minimum distance between a production text and a
part
DIST_TEXT_TEXT =10 - the minimum distance between two production texts
Solution: Corrected so the text will be placed correctly in the sketch.

Marine Drafting:

Incident Issue Description


Number Number
40888 Title: REVERT may corrupt Marine Drawing-files
Symptoms: After a REVERT command, the Drawing-files associated with the
selected session are now also used by a later session. However the system may
have created additional versions of these files in intermediate sessions, which are
not removed. When the user changes makes changes to the Reverted session,
the filenames may clash with the files created during intermediate sessions. This
results in data corruption, since the new files are not saved
Known workaround: Tidy up unused external files which post-date those
belonging to the session created by the REVERT before allowing the user to
make further changes.
Solution: Fixed by change to REVERT functionality. This now creates copies of
the original files with a 'High-water mark' version number. Although this results in
more files being retained, it reduces the possibility of data corruption
66380 126160 Title: Inserting an Assembly (via Insert Model) does not include Spools (spools
are not inserted into the drawing)
Symptoms: Spools missing when selecting an assembly, including spools.
Known workaround: No known workaround exists.
Solution: Spools drawn when included in assembly.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 417 of 517
Product Release Letter
Incident Issue Description
Number Number
68122 130617 Title: Problem to save the drawing as a new unique name when define DACs for
67541 134378 Department
Symptoms: Drawings are saved in the MOGWLD when DAC is defined.
Known workaround:
1. Create temporary PADD Database.
2. Set qualifying condition as (ATTRIB DBNA ,
'AFTDRAFT/GHOST_PADD' ) EQ false ) in DAC
3. Add this to first position in MDB
Solution: Fixed so drawings are stored in the correct location also when DAC is
defined.
68698 136008 Title: New Drawing/Open Drawing dialog: drawing name is cleared when
changing drawing type.
Symptoms: Drawing name is cleared when changing drawing type.
Known workaround: Re-enter name
Solution: The drawing name will now stay unchanged when changing the
drawing type
137830 Title: SVG in Marine Drafting needs enhancement
Solution: SVG file generated by Marine Drafting now contains additional
information about projection and transformation

Diagrams:

Incident Issue Description


Number Number
57079 96379 Title: Highlight Changes problem - UDAs not available in list for base types (only
for UDETs)
Symptoms: UDAs are not included in the set of attributes evaluated for Change
highlighting.
Solution: User can include UDAs of UDETs for Diagram Change highlighting.
60514 107093 Title: Attribute SCIREF is limited
Symptoms: User can't connect more than 10 elements to offline instrument
Known workaround: Create new offline instrument
Solution: SCIREF attribute has been expanded from 10 to 100 elements.
61849 111483 Title: Undo function
Symptoms: Undo does not work when user just moves component.
Known workaround: Executing "Undo" a couple of times might change back
shape position. Not recomended because DiagX/Ypos attributes might not be
properly updated.
Solution: Undo has been extended the cover new actions
65190 121812 Title: SCCAB as Secondary Shape can define STAREF and ENDREF differently
from Primary Shape
Known workaround: no known workaround / avoid operations on secondary
cable element, which can modify STAREF or ENDREF
Solution: Added new question dialog/setting before secondary cable connection
/ disconnection / deletion.
66910 129873 Title: REVERT deletes the files for the original session
Symptoms: if REVERT is used to switch between 2 sessions, the SVG files are
lost
Known workaround: Avoid use of REVERT or save the SVG files before using it
Solution: fixed
67414 129979 Title: UDA value change on multi-cable
Symptoms: UDA values are not propagated from multi-cables to cables
Known workaround: insert UDA values on cables manually
Solution: UDAs now dynamically added to propagation list on application startup.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 418 of 517
Product Release Letter
Incident Issue Description
Number Number
67469 130965 Title: Connecting more than 4 branches to inline component is not possible.
Symptoms: The database structure allows up to 10 branching connections
(determined by size of CRFA attribute), but when trying to connect more than 4
branches to inline component, the elements are disconnected and following error
message appears in message log: "Not a valid pipe connection".
Solution: The problem has been fixed - it is now possible to connect up to 10
branches to inline component
135974 Title: Application crashes when 'Customize' dialog is closing with contextual tab
active.
Known workaround: select another (non context) tab before entering Customize
dialog.
Solution: Added safety mechanism to handle any code exceptions
136426 Title: Batch Update
Symptoms: Inline elements became secondary after batch job update
Solution: Items that exists before secondary inline has been introduced will
became primary items after batch update.
68884 136761 Title: Object Reference Not Set to an Instance of an Object SI -68641
Symptoms: Unhandled exceptions occured during some operations on diagram
or during opening some diagrams.
Solution: Fixed unhandled exception during opening diagrams or doing some
operation on diagram.
62140 137707 Title: Text missing when Diagram is exported into AutoCAD
Known workaround: Save dwg file in 2000 version
Solution: String formatting encoding was enhanced, which resolved problems
with export to newer DWG file formats.

Schematic 3D Integrator:

Inciden Issue Description


t Number
Number
123889 Application crashed while working on 'Diagram Change Highlighting' when
'Integration with Schematics' is unchecked in Design Module.

Engineering:

Incident Issue Description


Number Number
64138 Title: Tags - Diagram Change Highlighting: Deletions or Additions are missing in
the list.
Symptoms: When base or target SVG is not present new elements and deleted
elements and attributes are not displayed
Solution: Earlier elements were retrieved from SVG files, now elements
are retrieved from database for selected target and base sessions
47986 74496 Title: Schematic Model Manager - Compare/Update: [Tags] Selected attributes
on grid does not properly update linked item
Symptoms: The attributes will not be updated, (even if they are selected) without
first selecting the item (clicking on the 'accept checkbox')
Solution: Now attributes are updated even if selected from attribute grid.
58626 100935 Title: Tags - Compare/Update: Remove "/" from all names in the array
Symptoms: In array attrribute type, the first object is displayed without the
leading slash, and the additional values are displayed with slash.
Solution: Removed slash from all values which present in array.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 419 of 517
Product Release Letter
Incident Issue Description
Number Number
58761 101327 Title: Tags - Cell forward on enter or tab
Symptoms: When the data enters into the large area, the option which was set
not working. The right cell is getting selected after pressing Enter button,
irrespective of the option chosen
Solution: Long Text Editor support direction set in options.
114074 Title: Schematic Model Manager - SCILINE elements are not being Highlighted in
Diagram Viewer Window
Symptoms: SCILINE was not considered as schematic line, so highlight was
getting failed.
Solution: SCILINE now considered as schematic line in drawing viewer.
117709 Title: Schematic Model Manager - Exception to be handle on click of Compare
CE.
Symptoms: Sometimes name attribute or unique attribute is missing in case of
with external source. It’s giving exception.
Known workaround: Proper attributes are required.
Solution: Proper message is displayed and Exception is handled when name
attribute or unique attribute is missing for external datasource.
64384 118742 Title: Tags - Compare/Update: Performance Issue of the grid result - phase 2
fixes
Symptoms: performance areas are row colouring after comparison and accept
all.
Solution: Performance is improved at the time of grid color and accept all.
64647 119564 Title: Tags - Compare Update: Save grid layout for user.
Symptoms: Element name with ":" selected as source gives error message when
user selects attribute from column setup
Solution: ":" is removed from file path which is coming from element type.
129515 Title: Tags - 3D View is getting displayed as cropped in tags module launched in
RDP.
Symptoms: Only small part of view is visible.
Solution: Routine which caused the problem has been exchanged.
131153 Title: Tags - UDA default value is not showing up in the tags grid
Symptoms: default values for the UDA ':test' are not showing up in the tags grid.
Solution: Changed the order of setting default null value for columns. It was the
cause of default values not showing in grid.
131364 Title: Schematic Model Manager - Compare/Update: when editing an existing
configuration, a new configuration with the same name is getting created.
Symptoms: Existing configuration getting created twice when user edits it, so
two configuration the same displayed in list.
Solution: Now only single configuration is displayed with unique display name.
133647 Title: Tags - The TagsAddin addin is not able to use network paths.
Symptoms: When starting Tags the following message appears:
Failed to start TagsAddin Addin…
Known workaround: Error message occurs when network paths are used e.g.
project_dir=\\servername\projects\121AENG\
To avoid this problem map network drive and adjust environment variables
appropriately.
Solution: The TagsAddin addin can now use network paths.
134306 Title: session comments not getting saved
Solution: Fixed an issue causing session comment not being properly saved
from PML Session Comment dialog.
136457 Title: Schematic Model Manager - Compare/Update: Implicit changes due
to implementation in Netgrid control in SP4.
Symptoms: Exceptions are thrown when forms having netgrid control is opened
Solution: Forms having netgrid control is displayed with no exceptions

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 420 of 517
Product Release Letter

Cable:

Inciden Issue Description


t Number
Number
49548 78607 Title: PDMS Cable Design - AVEVA Instrumentation Data Update use different
element types
Solution: New Out of box configuration has been introduced for AI Instrument
and Design database types Instrument, Equipment, Subequipment.

Pipe Fabrication:

Inciden Issue Description


t Number
Number
60614 114864 Title: Bend Elements Information in the PFBENDINGTABLE object
Symptoms: There was no information for bend length and radius in the
PFBENDINGTABLE object
Solution: Program modified to get bend element information in the
PFBENDINGTABLE object.
64116 117737 Title: Assign Bending Machine Form - Details Should Populate
Solution: Modified the Program to populate the Details tab when the Assign
Bending Machine form is opened
60922 108333 Title: The result of material list in spool drawing was error for joint sleeve spool
Solution: Compensated logic to get part number
61224 109505 Title: Changing SHOP attribute rise an error
Solution: Program modified to add logic to check whether "namopt" can be used
62578 113705 Title: Assembly Table Error for Flanged Branch
Symptoms: this problem happened when a branch is connected with tee as tail
Solution: Updated program to make assembly table for Flanged Branch properly
62583 113718 Title: Assembly Information Too Many Entries for Loose Flanges
Solution: Updated code to removed unnecessary information in the assembly
table
62598 113773 Title: Assembly Information - Name of BP is Missing
Solution: Updated codes to assembly information for "ELBO"
62620 113821 Title: Assembly Information - Mitre Information is Incorrect
Solution: Updated program to display mitre information properly.
62626 113853 Title: Assembly Information - BUTT is not Consistent with CUT Information
Solution: Updated program for consistency with CUT information about BUTT
data
57761 97660 Title: Assign Bend Machine Add Remove Items
Symptoms: It's not possible to remove selected elements in the grid
Solution: Program modified to add popup menu for removing selected elements
59776 104570 Title: Show User End/Feed Excess Pop Up Form
Solution: Updated program to remove pop up form for User End/Feed Excess. If
a spool has no User End/Feed Excess, the related button will be inactivated.
59839 104677 Title: Modify Spool Form Dynamic 3D View Update Required
Solution: Updated program to show end excess, feed excess, loose component
and spool limits automatically when changing pipes. If CE does not have above
values, the related button will be inactivated.
59842 104681 Title: View NC Data when selected check box
Solution: Updated program to fix this problem

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 421 of 517
Product Release Letter
Inciden Issue Description
t Number
Number
59844 104683 Title: Added Option for Modeling Consistency Check
Symptoms: The Modelling Consistency Check form will return a value of 'Not
Passed' for almost 95% of checks
Solution: The 'Full data consistency check' option has been added to bypass
many warnings
59968 105002 Title: Assign Bending Machine Highlight Selected
Solution: If type of selected element is BRAN, its members will highlighted
59969 105007 Title: Adding Icon to reflect the assignment result
Symptoms: The details tab of the Assign Bending Machine form does not have
a icon to display result
Solution: Program modified to add icon to display assignment result
60022 105115 Title: Assign Bending Machine Duplicate Errors
Solution: Added logic to check element before assigning error list
60023 105116 Title: Assign Bending Machine Form - No Highlight
Solution: Update to highlight the bending element which is to have modified
radius
60292 106394 Title: Create Weld by Picking will not work on Set-On Tees
Solution: Additional codes to pick set-on tee as advices
60477 106980 Title: Fabrication/Installation Isometric Form Population
Solution: Removed the logic to check removed items when adding elements
60489 107010 Title: Naming Pipe Pieces
Solution: Appended logic to assign autonaming for pipepiece element (PPIECE)
60727 134623 Title: Location of Check Message File in Pipe Fabrication
Symptoms: Program only will find the check message file in the PDMSEXE
folder
Solution: Program modified to find the file from PDMSDFLTS and PDMSEXE
folder If it is not in the PDMSDFLTS folder, the program will look in the
PDMSEXE folder
68713 136129 Title: Branch connected by PTAP is not shown on PSPOOL isometric.
Solution: Match PTAP with an OLET when comparing Isodraft internal type with
attribute BELTYP list
65363 122461 Title: Weldgap Config Form Initialisation Behaviour is Poor
Solution: Added logic for selection missing specs if there are any missing spec
for weld handling
67549 130649 Title: Modelling Consistency Form Error
Solution: Updated codes to get arrive connection to check flange rotation
67766 131412 Title: Spool Drawing Issues with # in Pipe Name
Solution: The “#” character will be changed to "_" to avoid the error
69599, 138861, Title: Fabrication Check Form Fails.
69639 138927 Solution: Exception has been handled.
69728 139229 Title: Coordinate Error on Elbow .
Symptoms: Coordinate Error on elbow is happened.
Solution: Program modified to get assembly table from elbow properly.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 422 of 517
Product Release Letter

Outfitting:

Incident Issue Description


Number Number
55404 92875 Title: Cats & Specs - Paragon's nozzle specification form with imperial bores.
Symptoms: When working in Paragon with 'INCH BORE" set, the nozzle
specification form assumes the parameter values retrieved from SCOMs are in
current units rather than assuming they are in database units.
Known workaround: Either add explicit units to the parameters on the SCOMs
before creating the specifications or manually edit the ANSW attribute on the
relevant specification selectors.
Solution: Fetch the bore values from the ppoints rather than from the
parameters.
55977 93925 Title: Cats & Specs - Nozzle SPEC, SELE, SPCO's are automatically getting
locked during creation.
Symptoms: Locked elements after creation/modification.
Known workaround: Select spec world and use 'unlock all' in the command
window.
Solution: Altered sequence of locking and unlocking so elements are left
unlocked instead of locked.
64443 118929 Title: Structures - Bent Panel Fittings Angle cannot be changed.
Symptoms: Bent Panel elements cannot be rotated.
Solution: A new attribute BFORI has been introduced.
64539 119230 Title: The input offset form fails to display in certain scenarios.
Solution: Add code to PositionControl.
64721 120297 Title: Isometric Automatic Drawing Production - IsoADP with MDS error.
Symptoms: An error message “(2, 769) An object does not have a member
METHOD” may appear when drawing supports for cable way or HVAC.
Solution: The application has been modified to find the MDS supports in both
HVAC and CWAY branches.
130845 Title: Piping - Porting back Sloping lines schema to maintain compatabilty with
E3D 2.1.
Symptoms: Interopability.
Known workaround: Don't use sloping lines.
Solution: Port code back.
132218 Title: Admin - Reconfiguration TO/FROM FILE only works if all drawing-files exist
in the original database
Symptoms: If a Sheet contains both Picture-file and Marine Drawing-files, then
both external drawing-files must be exist in order for Reconfiguration TO FILE to
work. If any file is missing, then Reconfiguration FROM FILE omits the Drawing-
file copy. Any existing files will be copied alongside the Reconfigurer files during
the Output stage, but they will not be read in and updated during the Input stage
to the destingation database.
Known workaround: Use Reconfiguration TO DB to avoid the problem
Solution: Fixed
68228 134724 Title: Draft - (2,779) Method <ERROR>.WRT(<DBREF>) displayed when
creating CWAY Isos.
Solution: Fixed to handle case when a POINTR is the last component in the
spool.
68860 136610 Title: Hidden Views are exported to DWG.
Solution: This issue has been solved.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 423 of 517
Product Release Letter
Incident Issue Description
Number Number
69114 137562 Title: Piping - Hole Management data being written to MDS association world.
Symptoms: Hole management association group created in MDS association
world.
Known workaround: Make sure that a writable hole management association
group is available to all users.
Solution: The system now checks for ASSOWL purpose, and will not attempt to
create a new ASSOGP in an MDS association world.
69107 137567 Title: Design - Position from Hole Management report is not the position of
penetration if an offset is applied
Symptoms: Offset applied to holes is not included in the penetration position
Known workaround: Use the position of the virtual hole (No problem with holes
with no offset applied)
Solution: Output on report position with offset applied
69529 138719 Title: Admin - PNS (Privileges Not Sufficient) Error with foreign DB in
12.1.SP4.12.
Symptoms: If read only access is applied to databases a PNS error is given on
module entry.
Known workaround: If appropriate, do not set read only permission to
databases.
Solution: Use fix provided in 12.1.SP4.13.
138878 Title: Piping - User not able to connect the Pipe Branch to a Equipment Nozzle.
Solution: Corrected PML.

12.1.SP4.12

Planar Hull:

Incident Issue Description


Number Number
I-64576 119373 Title: FRP weight wrong.
Symptoms: Weight and CoG is not correct for some FRP items.
Known workaround: No known workaround exists.
Solution: Corrected calculation of WCOG for stiffeners, flanges and trapezoids
done when verifying and splitting the panel.
Corrected calculation T-bar bead core weight in material list.
I-66186 134472 Title: Planar Hull | Model | Divide function - error dividing groups of seams.
Symptoms: Planar Hull | Model | Divide function handles groups of seams
incorrectly when seams are defined "parallel to limit". Resulting seam statements
are incorrect and return error message when running the scheme.
Known workaround: Manually maintain the seam handling via the schema file.
Solution: The values of the keywords M1, M2 and NUM are correctly updated
after Divide group. Also if a single seam is placed in a new group, the M2 and
NUM keywords are omitted.
I-68394, 135192, Title: Name of flange is different in model (wrong) and ATX file (correct)
I-66347 126031 Symptoms: The partname of curved flanges in a SP panel is wrong (symmetry
letter is wrong).
Known workaround: No known workaround exists.
Solution: Corrected so the part name for the curved flange is correct.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 424 of 517
Product Release Letter

Curved Hull:

Incident Issue Description


Number Number
I-67977 134447 Title: Hull Curves appear under wrong Surface.
Symptoms: Creating a Hull Curve, it turns up in the wrong surface.
Known workaround: No known workaround exists.
Solution: Hull curves now end up under the surface they were created in
regardless of how they were created.
Hull curves created from geometry defined in the drawing are still placed under
the main surface, but this is purely for administrative reasons as they do not
belong to any surface.

Hull Production:

Incident Issue Description


Number Number
I-62509 113558 Title: AutoBevel does not working for Shell profile.
Symptoms: Using the option Auto Bevel for Shell Profiles, defined with a 3D
curve, does not work.
Known workaround: No known workaround exists.
Solution: Corrected so that Autobevel also works for Shell Profiles defined with a
3D curve.
I-64290 122548 Title: Jig Subpicture and section view are incorrect.
Symptoms: The Jig planes defined by 3 points gives very strange views on the
resulting drawings.
Known workaround: No known workaround exists.
Solution: corrected so the views are correctly presented and the plane is also
correctly calculated.
I-66347, 126031, Title: Pillars of CL panel is stored to pldb with incorrect symmetry.
I-68394 135192 Symptoms: Pillars in CL gets different parts names in different applications.
Known workaround: No known workaround exists.
Solution: Pillars in CL (cogY=0) will always be considered as PS parts and the
part name will in all instances present this.
I-63498 129716 Title: Post-Processor Omnimat L6000 Test failed.
Symptoms: Arcs are erroneous stored in the postprocessor file.
Known workaround: No known workaround exists.
Solution: Correction in customer postprocessor files so arc is correctly stored.
I-68362 135107 Title: The PART_ID of Hole is diffener in Gen.File.
Symptoms: PART_ID in the generic file for holes does not reflect the CNT no
given in the planar panel in the HOL statement.
Known workaround: Manually change in the generic files to the correct
PART_ID.
Solution: Corrected so the PART_ID will be the same as the CNT number given
in the planar panel statement for the hole.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 425 of 517
Product Release Letter

Hull Weld Planning:

Incident Issue Description


Number Number
I-68272 125318, Title: WeldPlanning Report - Data missing.
134954 Symptoms: The definitions in weldPosition.def is not considered when the report
is produced.
Known workaround: No known workaround exists.
Solution: Corrected so the definitions in weldPosition.def is handled and used in
the report.

Hull Nesting:

Incident Issue Description


Number Number
I-65353 122473 Title: Autonesting name can be set with a ruler.
Symptoms: Enhancement request to extend automatic nesting names.
Known workaround: No known workaround exists.
Solution: Additions to the automatic drawing names option has been introduced
to also handle nesting names.
New statement is: PLATE_NEST.
New attributes are: THICKNESS and QUALITY (only valid for PLATE_NEST).
Example of nesting names can be: PLATE_NEST/BLOCK_NAME /DELIM=' '
/QUALITY /DELIM=' ' /AUTO_SEQNO=6;
I-67483 130190 Title: Nesting is storing the wrong nesting in some cases.
Symptoms: in Nesting, have the MANU explorer open and Current Element (CE)
set to another nest than the one in use, save the CE nest and not the Nesting in
use.
Known workaround: Make sure CE and the nesting in use are the same before
saving the nesting.
Solution: Corrected so it is the nesting in use that is saved no matter which
element that is CE.
I-67488 130207 Title: Nesting, in several nestings the SAVE button is grey.
Symptoms: Open an old nesting makes the Save button to be greyed out.
Known workaround: No known workaround exists.
Solution: The nest is most probably a very old nest containing parts created via
the nesting tool Part Create. Over time there has been additions to nestings and
in those very old nestings, this addition is missing causing the nesting system to
misunderstand the intention and hence blanking the possibility to save the
nesting. This is now removed so a nesting will always be possible to save.
I-67489 130218 Title: Nesting, labels cannot be deleted any more (greyed out).
Symptoms: Adding a label in nesting using Key In option, the delete function of
labels are greyed out and it is not possible to remove the label text again.
Known workaround: If a label text, using the Production Information option is
used the first time in the session, the Delete Label function will be visible through
the whole session. The issue is only if Key In option has been used the first time
in the session.
Solution: Corrected so also Key In option may be used the first time.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 426 of 517
Product Release Letter

Marine Drafting:

Incident Issue Description


Number Number
I-61097 108863 Title: DXF 3D error.
Symptoms: In DXF Export, if an assembly contains only a few parts from a
planar panel, the whole planar panel is exported.
Known workaround: No known workaround exists.
Solution: Corrected so only the parts in the assembly are exported. Existing
views must be recreated.
I-63577 116476 Title: Weight & COG dimension does not work for shell plates and shell stiffeners
in assembly model.
Symptoms: Error message "Model object xxx not treated in this function!".
Known workaround: None.
Solution: It is now possible to calculate WCOG on shell plates/shell stiffeners
when drawn as assembly.
I-66236 125593 Title: Default view property is not utilized when Marine Drafting is first launched.
Symptoms: The default VIEW_TYPE is defined but it does not give the expected
result.
Known workaround: If VIEW_TYPE consists of only Upper Case letters this will
work.
Solution: The value was converted into uppercase letters and then not
recognized by the function. This is now corrected so the value is not translated
into uppercase letters.
I-66417 126272 Title: Command tooltips are listing their CTRL hotkeys twice.
Symptoms: When hovering over a menu command (or toolbar command) that
has a hotkey, then the tooltip is listing the hotkey twice (i.e. Create a new
drawing (Ctrl N)(Ctrl+N)).
Known workaround: No known workaround exists.
Solution: Duplication of hot key names in tooltips now removed.
I-66320 126513 Title: Marine Drafting does not remove obsolete views.
Symptoms: Empty sub-picture views remains in the drawing.
Known workaround: Manually delete the views in the Drafting explorer.
Solution: When purge is ordered explicit (via Tools/Inspect drawing/Purge or
right-click/Purge in the Marine Drawing Explorer) empty DO views will be
removed together with referred PADD views. It is up to the user to make sure
nothing of interest in such a PADD view is lost.
However, we will keep the safe way during automatic purge (not ordered by
user).
I-66571 126894 Title: Uppercase drawing names not being maintained during alternative copy
routine.
Symptoms: Opening a drawing that is claimed by another user prompts for a
new name of the drawing. If the default DWG_NAME_UPPERCASE is defined
as YES, the system is not forced to capital letters.
Known workaround: Make sure uppercase letters are used either by the Shift
key or Caps Lock set.
Solution: Corrected so capital letters are always forced when
DWG_NAME_UPPERCASE is defined as YES.
I-66627 126900 Title: Incorrect when using the stretch commands on RECTANGLES.
Symptoms: When using the Stretch function on rectangles, only one side is
correctly stretched.
Known workaround: Dechain the contour and then use the Stretch function.
Solution: Corrected so Stretch works on all segments in a rectangle.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 427 of 517
Product Release Letter
Incident Issue Description
Number Number
I-67162 129097 Title: Problem to find user defined drawing types when
IGNORE_MARPTYPE_FOR_USERDEF =Yes .
Symptoms: In the Open Drawing dialog you will not see all the sued defined
drawings.
Known workaround: No known workaround.
Solution:
1. When searching for a user defined drawing type in the Open Drawing dialog
AND IGNORE_MARPTYPE_FOR_USERDEF =Yes then the system will
automatically limit the search to the department set up by SB_PDB00x_PADD.

2. In case you need to search the whole mdb for user defined drawing types
when IGNORE_MARPTYPE_FOR_USERDEF =Yes, we have implemented a
new option: "All Drawings" which is a new choice available in the list of drawing
types in the "Open Drawing" dialog. When using this the system will only search
for drawings with a matching name disregarding of what type they are. Please
note that this search can be significantly slower than searching for a specific
drawing type.
I-67951 134197 Title: System not recognizing all occurrences of a pipe branch subpicture when
deleting.
Symptoms: When identifying a Pipe (subpicture level 2) for deletion in the
drawing, the pipe is not recognized in all views.
Known workaround: No known workaround exists.
Solution: When searching for subpictures with same name, the fact that the
name of a model subpicture might be stored as a db-ref instead of the explicit
name has been considered. Also implemented support for long names when
identifying subpictures by name.

Diagrams:

Incident Issue Description


Number Numbe
r
122623 Title: Unmapped attributes are not displayed in the output EIWM file when Keep
unmapped attributes is checked.
Symptoms: Unmapped attributes are not displayed in the output EIWM file when
Keep unmapped attributes is checked.
Known workaround: No known workaround.
Solution: Unmapped attributes are now displayed in the output EIWM file when
Keep unmapped attributes is checked.

Engineering:

Incident Issue Description


Number Number
I-59950 104969 Title: Tags - Provide a PML function to send information to the Message Log
windows in Tags and Diagrams.
Symptoms: Currently it is not possible to send information to the Message log
windows from PML scripts.
Known workaround: No known workaround.
Solution: Added possibility to send information to the Message log windows from
PML scripts by new method:
AddMessage(string severity, string message) to PMLTags class.
Possible severity strings are 'ERROR' 'WARNING' and 'INFO'.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 428 of 517
Product Release Letter
Incident Issue Description
Number Number
I-60210 106087 Title: Tags missing attributes for Hull Element Types.
Symptoms: Hull element types are missing, so consider as string in comparison.
Known workaround: No known workaround.
Solution: Added a condition to display hull element type.
112677 Title: Tags - Long text editor eats the first keystroke.
Symptoms: First letter is removed when trying to type in long text editor.
Known workaround: No known workaround.
Solution: First letter is not removed when trying to type in long text editor, whole
text is visible in long text editor.
I-63157 115679 Title: Tags - Performance issue in Cell History.
Symptoms: Performance for Cell History was poor.
Known workaround: No known workaround.
Solution: Performance is improved for non expression and non pseudo attribute
type of columns.
I-63786 117851 Title: Tags - Error running macro in Engineering Tags since moving to
PDMS12.1SP4Fix5.
Symptoms: There is an exception when trying to publish to AVEVA NET from
macro in Engineering Tags.
Known workaround: No known workaround.
Solution: First issue was an old Aveva.Pdms.Tags.Pml.dll version in the package,
we have added also null-check which caused an exception while running macro.
I-65580 123272 Title: Tags - List Manager - 3D Object icon appear, even if there is no 3D Object.
Symptoms: 3D Object icon appears, even if there is no 3D Object.
Known workaround: No known workaround.
Solution: 3D Object icons do not appear if there are no 3D Objects.
I-65890 124325 Title: Reloading PBS from datal macro is not working properly
Symptoms: During reloading PBS from datal macro, the PBSPAR was not set
correctly if it referred to more than one element. As a result it was not possible to
move PBS structure between projects using datal.
Known workaround: Manually adjust PBSPAR after running datal macro.
Solution: Setting the PBSPAR attribute from datal macro and from command line
is working fine now.

Pipe Fabrication:

Incident Issue Description


Number Number
I-59801 116747 Title: Cut Information Table for Elbow.
Symptoms: When create pipe spool drawing, there is no cut information table for
elbow.
Known workaround: No known workaround exists.
Solution: Program modified to create cut information table.

Multi-Discipline Supports (MDS):

Incident Issue Description


Number Number
99638 Title: Improper Error Message while Creating Trunnion TT25.
Symptoms: Creating TT25 on a horizontal pipe results in improper error
message.
Known workaround: TT25 is for vertical pipes only. Error only exists if user tries
to create one on a horizontal pipe.
Solution: Fixed by adding a condition that the selected pipe must be vertical. An
error message is displayed if the selected pipe is not vertical.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 429 of 517
Product Release Letter
Incident Issue Description
Number Number
100300 Title: Trunnion dummy legs lengths are not reset after creating the VT07 vessel
support.
Symptoms: Works in a different way to VT01 creation.
Known workaround: It is still possible to control the lengths of the dummy legs,
but the workflow is different than with other similar VTs.
Solution: Brought the functionality for VT07 in line with VT01. Now the dummy
legs are resized to an appropriate length.
101472 Title: Add Support buttons on ribbon bar should not do anything at piping
component level unless it is an ATTA.
Symptoms: When at an elbow for example it would add all supports on the
branch.
Known workaround: No known workaround exists.
Solution: It now only adds supports at a branch level or at an ATTA of a support.
101482 Title: Inconsistency observed in the confirm message while removing the Grid
System.
Solution: Changed content of displayed message from 'O.K.' to OK to be
consistent with other similar messages.
101483 Title: MDS ABA Grid Data window fails to get dismissed on Clicking on ‘X
‘Button.
Symptoms: Form cannot be closed with 'X' button.
Known workaround: Use the 'Dismiss' button.
Solution: The 'X' button now closes the form in the same way as the 'Dismiss'
button.
102544 Title: Compensation Materials form would not display materials.
Symptoms: Compensation Materials form would not display materials if the units
were not set to Celsius and Pascals.
Known workaround: Switch units to Celsius and Pascals and then switch them
back afterwards.
Solution: The form now shows the correct materials for when the units are set to
any values.
104201 Title: Using 'Adjust to Steelwork' functionality on ST06 results in error message.
Symptoms: Cannot perform required functionality, resulting in error message.
Known workaround: ST06 can be manually adjusted to steelwork by user input
of explicit values.
Solution: Adjust to steelwork functionality is now fixed.
116574 Title: Reference supports were not moved when the support was moved.
Symptoms: Any reference supports created on a support framework were not
moved with the framework.
Known workaround: No known workaround exists.
Solution: Reference supports are now moved with the framework.

Outfitting:

Incident Issue Description


Number Number
I-55831 93650 Title: Cable - Copy CableWay Elements(syntax error).
Symptoms: Syntax error occur when using Copy CableWay Elements.
Known workaround: No known workaround exists.
Solution: Defect is now corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 430 of 517
Product Release Letter
Incident Issue Description
Number Number
I-56051 94077 Title: Cable - List of Elconns form throws F&M warning when loaded for the first
time.
Symptoms: If a user clicks the Pick link label on the start ref or end ref in the
Create cable form they get a warning.
Known workaround: No known workaround.
Solution: Defect is fixed; the problem was in positioning the PML gadget, which
was placed outside the boundaries of the form.
I-58219 99125 Title: Design - Creating a part from a template no longer defaults to the DESIGN
db.
Symptoms: The catalogue search panel always initialises the DB type to
catalogue.
Known workaround: Use gadget to select appropriate DB type.
Solution: Initialise gadget with correct DB type rather than the default DB type.
I-59660 104514 Title: Piping - Problems with connecting a branch to a CROS.
Symptoms: When you try to connect a branch head or tail to a CROS using
pick, the error element that does not have attribute CREF appears and the action
is prevented.
Known workaround: Use the old connect form.
Solution: An extra error handle has been added to bypass the problem.
I-61407 110236 Title: Design - Position via Ship Reference does not work the first time after a
copy.
Symptoms: After Copy STRU, Ship Position Form Apply does not work (first
time only).
Known workaround: After Copy STRU had to Position twice using Ship Position
Form.
Solution: This issue has now been corrected.
I-62021 111997 Title: Design - Could not add CE when CE was a BLOCK to the mass surface
and mass volume form.
Symptoms: Block was not added to the .net grid on the form for calculation.
Known workaround: User could add BLOCK by Name.
Solution: This issue has now been corrected.
I-62565 113666 Title: Piping - Unhandled error in pipe splitting.
Symptoms: During pipe splitting there can be an error message "problem
creating the dummy assembly" if a component stype is unavailable in the current
spec. This causes another error and the process halts with "array element 0 does
not exist".
Known workaround: This is caused by using plant assemblies in marine where
the specs are incompatible. The assemblies should be re-built in the marine
sample project.
Solution: An extra error handle has been built into the assembly code.
I-64729 120326 Title: Fixed PML STOP button not working on Windows 7.
Symptoms: STOP button does not always interrupt PML on Windows 7.
Know workaround: No known workaround.
Solution: This issue has now been corrected.
I-66297 125876 Title The Pipe component selection form opening and closing will make the
software crash ( fatal error if console is shown).
Solution: Added a check in the code to prevent the form from crashing.
I-66357 127662 Title: Design - Incorrect work Advanced View Control with Measure Distance
functionality (lost a dimension).
Symptoms: Error concerning no aid number.
Known workaround: No known workaround.
Solution: Advance view form did register aids but did a .remove( instead of
.hide(
128816 Title: Design - Autofill straights with wrong orientation.
Symptoms: Autofill straights with wrong orientation.
Known workaround: Reconnect.
Solution: This issue has now been corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 431 of 517
Product Release Letter
Incident Issue Description
Number Number
I-64762, 128948, Title: Design - Unreliable PML file-saving on Windows 7.
I-67188 129208 Symptoms: PML applications show PNS (Privileges not Sufficient) on alternate
operations – can affect Reporting, Savework Design Colours etc. Applies to
Windows 7 (or higher) file-shares.
Known workaround: Problem may be resolved by repeating operation.
Solution: This issue has now been corrected.
135489 Title: HVAC Syntax error message is displayed on selecting Connect Tail to Last
Member.
Symptoms: Syntax Error.
Known workaround: Set TCON in attributes form.
Solution: Fixed using PML2 syntax.

12.1.SP4.11

Planar Hull:

Incident Issue Description


Number Number
I-64233 119205 Title: The option for allowing the managed holes to be deleted.
Symptoms: There is no easy way to disconnect managed holes on e.g. sister
ships where just the hull data is available.
Known workaround: Manaully remove the holes from schemas and rerun.
Solution: A new option to the Hull Verify application has been introduced,
&DISCONNECT_MANAGED_HOLES. This is not available as any interactive
function but the program sj011.exe will recognize this keyword and disconnect
the managed holes for the selection (blocks or individual panels).

Curved Hull:

Incident Issue Description


Number Number
I-63393, 115908, Title: Wrong Symbolic View of shell plates on closed Surfaces
I-64907 121978 Symptoms: When using Shell Plate Compensation in a closed surface, the
curves are not correctly presented in a symbolc view.
Known workaround: No known workaround exists.
Solution: Corrected so the Shell Plates are correctly presented in the symbolic
views.
I-64905 120857 Title: The dimension should consider the shrinkage.
Symptoms: The marAPI function RemarkingLengthExt does not consider the
flags for shrinkage, excess or compenastion.
Known workaround: No known workaround exists.
Solution: Corrected so all flags are considered.

Schematic 3D Integrator:

Incident Issue Description


Number Number
I-61495 110432 Title: After an unlink any accepted differences should be removed.
Symptoms: Accepted differences remain after unlinking.
Known workaround: Reject accepted differences before unlinking.
Solution: Acceptance data are removed on unlinking.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 432 of 517
Product Release Letter
Incident Issue Description
Number Number
I-60698 111018 Title: After rejecting an accepted differences any acceptance group member
should be removed.
Symptoms: Acceptance group members remain after rejecting accepted
difference.
Known workaround: Manually remove items from the acceptance group, or
ignore them.
Solution: Acceptance group members are removed on rejecting an accepted
difference.
113140 Title: Integrator at 12.1.SP4 should be able to cope with an E3D2.1 configuration
file.
Symptoms: Integrato throws unhandled exceptions if it encounters a leter
configuration rule.
Known workaround: Use a configuration file generated at 12.1.SP4.
Solution: Handle errors from referencing attributes not available at earlier
versions.
I-62964 114737 Title: Branches of unlinked pipes have options to accept differences.
Symptoms: Branches have options to accept differences which should not be
available if pipe is unlinked.
Known workaround: Ignore these options or reject any accepted differences.
Solution: Accept differences options are not available on branch if pipe is
unlinked.
I-62968 114741 Title: After rejecting an accepted differences any acceptance group member
should be removed.
Symptoms: Acceptance group members remain after rejecting accepted
difference.
Known workaround: Manually remove items from the acceptance group, or
ignore them.
Solution: Acceptance group members are removed on rejecting an accepted
difference.
I-63096 115389 Title: Tags - Enhance the Validate process of Manage Links to merge partially
populated link objects.
Symptoms: Separate link objects sharing one of the same references.
Known workaround: None.
Solution: Validate option merges links that overlap in their references.
I-63704 116814 Title: Copy All to 3D not done for all pipes in multi-linked line.
Symptoms: Only the first pipe that is linked gets the attribute values copied to
3D.
Known workaround: Manually copy the attribute values.
Solution: Copy All to 3D copies the attribute values to each linked pipe.
116906 Title: A branch with no significant components is not compared.
Symptoms: The branch is coloured cyan following comparison.
Known workaround: None.
Solution: Branches with no significant components are compared according to
their connections.
116907 Title: Integrator matches a schematic valve to a PCOM when it should be
reporting a missing valve.
Symptoms: A missing valve is not reported.
Known workaround: None.
Solution: The matching has been improved to correctly report the missing valve.
I-65499 122897 Title: Tooltip reports a difference even though the rules say to ignore that
attribure.
Symptoms: The tooltip for an attribute set to Compare Action Ignore reports a
difference.
Known workaround: None.
Solution: The tooltip takes account of the Compare Action setting.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 433 of 517
Product Release Letter

Engineering:

Incident Issue Description


Number Number
I-58620, 100915, Title: Tags - Enhance the Validate process of Manage Links to merge partially
I-63096 115389 populated link objects
Symptoms: Separate link objects sharing one of the same references
Known workaround: None
Solution: Validate option merges links that overlap in their references.
I-67195, 129710, Title: Tags application does not load lists definitions.
I-67913 133268 Known workaround:

TagsAddin uses three environment variables XXXDATA (Where XXX is short


project name e.g. SAM), PDMSDFLTS and PDMSUSER to evaluate folders
where list definitions are saved/loaded.

%PDMSUSER%\XXX\Data\Lists\
%XXXDATA%\Lists
%PDMSDFLTS%\Data\Lists

If all three environment variables exist and their values are set (paths) then
everything should work.

Solution: Additional checking to prevent from referencing to not existing objects.

Outfitting:

Incident Issue Description


Number Number
I-65389 122760 Title: Design - In Outfitting Module, Cannot snap the Centre point for Hull
Panel Hole.
Symptoms: Centre points can be snapped but there should also be additional
points in manholes (HO).
Known workaround: No known workaround exists.
Solution: Two new ppoints has been added to the HO standard hole type. On at
each centre of the arcs.

12.1.SP4.10:

Planar Hull:

Incident Issue Description


Number Number
I-51068 81884 Title: The WEL is not required Information in scheme.
Symptoms: In the seam (SEA) statement, the keyword WEL always turnes up
with two vaules not defined by the user. This often happens on a seam based on
a previous defined curve via CUR statement.
Known workaround: Manually remove the values (and the keyword).
Solution: Corrected so the WEL keyword with values only appears if given by the
operator.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 434 of 517
Product Release Letter
Incident Issue Description
Number Number
I-59185 102751 Title: FunctionalDescription cannot select blank from second Rename function.
Symptoms: Using the function Panel->Rename the first time will show a blank
field in Functional Description (FD). The second time it is not possible to select a
blank FD.
Known workaround: Add any FD and then remove it in the Schema Editor.
Solution: Blank value of FD will always be possible to select in the Rename
function.
I-59398 103627 Title: When modify boundary, Limit No. does not match in GUI.
Symptoms: Modifying a planar panel boundary that referes to another planar
panel limit, in the Boundary Wizard, the limit number changes.
Known workaround: No known workaround exists.
Solution: The correct limit number will be presented in the Boundary Wizard
when modifying such boundary.
I-61761 111268 Title: No shell profile in the symbolic view.
Symptoms: A view plane, intersecting a Shell Profile in a Cylindrical surface is
not presented in the symbolic view.
Known workaround: No known workaround exists.
Solution: The problem has been solved so that shell profile section is drawn in
the symbolic view. However the plane must not be outside the starting and
endpoint.
I-63933 117333 Title: The comment of hole is not output to Gen.File.
Symptoms: Generating fictious holes are not fully represented in the plate
inteface generic file.
Known workaround: No known workaround exists.
Solution: All information regarding the fictious hole will be included in the generic
file.
I-64578 119369 Title: Knuckle panel, stiffener's PartName and PartId are unmatch.
Symptoms: The stiffener part id (PrtIdl) is not correct for stiffeners on a knuckled
panel.
Known workaround: No known workaround exsits.
Solution: Corrected so the part id is correct also for stiffeners on a knuckled
panel.
I-64622 119544 Title: Free naming for profs / seams, not possible to create proper plane panels
Symptoms: in the boundary statement, referring to another planar panel whos
name only consits of numbers in the last part of the name will fail (ex. ABC-1234).
Known workaround: Make sure also letters are used in the last part of a panel
name (ex. ABC-A1234).
Solution: Panels with only number in the last part will also be recognized as
planar panels.
I-65523 123061 Title: Captured 3D View position wrong.
Symptoms: Indicating in a isometric view gives wrong coordinates when
modelling holes on a planar panel.
Known workaround: Use a non-isometric view to get correct indication.
Solution: The problem has been solved so that it is possible to indicate the
coordinate position for a Hole in the isometric view.
I-65931 124424 Title: SBH_AN_POS and SBH_HOLE_GPS are not able to define both
Symptoms: When SBH_AN_POS and SBH_HOLE_GPS is both defined in a
project, the GPS1 - GPS44 is not available for Holes in planar panels in the
Statement Wizard.
Known workaround: Manually handle the GPS1- GPS4 in the panel schema.
Solution: GPS1 - GPS4 for planar panel holes are always available in the wizard
if SBH_HOLE_GPS is defined.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 435 of 517
Product Release Letter
Incident Issue Description
Number Number
I-66159 125056 Title: Rename function problem.
Symptoms: Using the Planar Panel Rename function, changing the Block name
has no affect on the panel. Instead an error message ""Failed deferred storing
<panel_name>" is shown in teh message window.
Known workaround: Make sure the panel schema exists. Then delete teh panel.
Change block name in the schema and run the schema to create the panel again.
Solution: Corrected so it is possible to change Block name in the Rename
function.
I-66649, 126959, Title: Endcuttab error in SP4.
I-66653 126982 Symptoms: Creating the endcut table with the input file does not work in
12.1.SP4. this worked fine in 12.1.SP3.
Known workaround: Temporarly use an installation of 12.1.SP3 to create the
endcut table.
Solution: Corrected so that inithull will create the endcut table correctly in
12.1.SP4.
I-66863 127658 Title: Panelnames as OBJ in MOGWLD.
Symptoms: When releasing panels for production (ppanparts) some parts ends
up in the MOGWLD.
Known workaround: Check log file for potention error messages.
Solution: something has gone wrong in the processing of the part. The part will
not be saved and possible error messages must be checked for in the log-file.

Curved Hull:

Incident Issue Description


Number Number
I-64906 123096 Title: The 3D model view error, if the endcut angel is small.
Symptoms: An endcut with a small endcut angle on a twisted profile is shown
incorrect in 3D.
Known workaround: No known workaround exists.
Solution: Corrected so the endcut is shown correct also in 3D.
I-65879 124362 Title: Negative Excess could not be added to curved stiffener.
Symptoms: It is possible to add Negative Excess to a Curved Stiffener via XML
input but not in the Interactive Method.
Known workaround: Define the Negative Excess in the XML schema of the
Curved Stiffener.
Solution: Negative Excess is also accepted by the Interactive Method when
modifying a Curved Stiffener.
I-62647, 124735, Title: Shell Stiffener shown incorrect in 3D view
I-66772 127393 Symptoms: A part of shell profile is presented with a wrong angle.
Known workaround: No known workaround exsist.
Solution: Corrected so the shell stiffener angle is correct.

Hull Structural Design:

Incident Issue Description


Number Number
I-57423 99919 Title: Unusual shell profile names allowed.
Symptoms: Possible to create shell profiles with number higher than 9999. This
later on causes other problems since the system will not recognize the shell
profiles in all cases.
Known workaround: Avoid creating shell profiles with higher number than 9999.
Solution: It is now prevented to create shell profiles with higher number than
9999.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 436 of 517
Product Release Letter
Incident Issue Description
Number Number
I-66937 124253, Title: A panel created by toggle divide has strange seam definion.
128054 Symptoms: When the split panel is divided by a seam for the intersecting pane,
the seam statement is not complete. it ends with COM= and then nothing more.
Known workaround: In the schema, manually correct the statement and run the
panel.
Solution: Corrected so the SEA statement will be correct.

Hull Production:

Incident Issue Description


Number Number
I-51018 81813 Title: All Character does not appear in GUI.
Symptoms: Forms for Shell Plates and Shell profiles are missing some text when
run on a Japanese OS.
Known workaround: No known workaround exists.
Solution: The missing texts are now also visible when run on a Japanese OS.
I-57733 97606 Title: 3-pts panel marking is displayed in the other panel(Gen.file).
Symptoms: Some un-necessary marking of other panels when the distance
between them is small but marking is not expected.
Known workaround: No known workaround exists.
Solution: Corrected so the un-expected marking is not added.
I-61519 110445 Title: It has not been calculated as Mandatory of Bending templates.
Symptoms: Result list is to some extent different since VM11.6
Known workaround: No known workaround exists.
Solution: For calculation of Normal (mandatory) templates, frame positions are
not used. Normal template is a variation of standard templates that do not use
frame positions.Therefor frame terms is not listed in the list file of pin heights in
12.1.X versions of normal bending template.
120726 Title: Send SUBS to Production.
Symptoms: STRU and SUBS cannot be used in Outfitting Structure Production
(OSP).
Known workaround: Use FRWM instead.
Solution: Corrected so also STRU and SUBS can be used in OSP.
I-65068 121275 Title: Branch Frame number(FR501 over) is not displayed in Production
interface.
Symptoms: Option to select frame positions in Bending Templates where the
number is above 500 is not possible.
Known workaround: No known workaround exists.
Solution: Corrected so it is possible to selec frame numbers above 500.
I-66747 127154 Title: Bending templates is not working.(fatal error).
Symptoms: Calculating Bending Templates for a curved Panel with Excess
defined on a plate limit, before (or after) two combined plate limits, aborts the
system.
Known workaround: No known workaround exists.
Solution: Corrected so excess information will be handled correctly and the
system will not abort.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 437 of 517
Product Release Letter
Marine Drafting:

Incident Issue Description


Number Number
I-59138, 102655, Title: FIXING is not being handled properly through the subpicture levels.
I-59362 103535 Symptoms: Difficulties to handle fixings in Marine Drafting.
Known workaround: No known workaround exists.
Solution: See Release Letter, List of Enhancements for 12.1.SP4.4 "Marine
Drafting - WCOG for outfitting Models" where the keyword
AUTO_OUFITTING_LEVEL has been extended to the following interactive and
Vitesse/MarAPI functions:
Model/Copy
Model/Present
Model/Exchange
DXF Export (Outfitting not handled)
model_identify
model_handle_get
model_colour_set
model_delete
Model/Delete
Model/Modify Colour
Model/Modify Linetype
model_highlight
I-66224 125453 Title: MarSymbolicView Class is not working correctly.
Symptoms: MarSymbolicView Class properties have "_" in the name. This is
valid only for forms/gadgets in PML, origin return always [0,0,0], PlaneTypePML
return always -1.
Known workaround: No known workaround exists.
Solution: This is now corrected. New Property names for PML usage also
implemented.
I-66308 125947 Title: 3D coordinate failing on SCTNs on 2nd elements added to view.
Symptoms: When adding more elements to a STRU in a drawing, the 3D
coordinate fails to get correct coordinates.
Known workaround: No known workaround exists.
Solution: Corrected so all 3D coordinates are correctly fetched.
I-66619 126892 Title: Corrected Escape/Enter key functionality.
Symptoms: Escape/Enter key does not work in all situations and cause 2d view
to lose focus.
Known workaround: User can manually give focus to 2d view, e.g. by
clicking on mouse wheel.
Solution: This has been corrected so user do not have to manually change
focus.
I-66516 126896, Title: Unexpected results when engaging the OPTIONS during an Intersection
Point selection.
Symptoms: Issues when using the Option command (F10) when in Point
Selecion. system loose focus and user must make new active selection.
Known workaround: Make Right Click to retain the system focus.
Solution: F10 as Option is removed due to clash with F10 function in Outfitting
where this is the toggle between XYZ/ENU coordinate presentation. The single-
key accellerator "P" is still available to use as option.
I-66659 127028 Title: Apparent loss of focus when using OPTIONS with Modify > Trim > Gap.
Symptoms: Issues when using the Option command (F10) when in Point
Selecion. system loose focus and user must make new active selection.
Known workaround: Make Right Click to retain the system focus.
Solution: F10 as Option is removed due to clash with F10 function in Outfitting
where this is the toggle between XYZ/ENU coordinate presentation. The single-
key accellerator "P" is still available to use as option.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 438 of 517
Product Release Letter
Incident Issue Description
Number Number
I-66677 127029 Title: Apparent loss of focus when identifying ISLANDS during the creation of a
HATCH pattern.
Symptoms: Issues when using the Option command (F10) when in Point
Selecion. system loose focus and user must make new active selection.
Known workaround: Make Right Click to retain the system focus.
Solution: F10 as Option is removed due to clash with F10 function in Outfitting
where this is the toggle between XYZ/ENU coordinate presentation. The single-
key accellerator "P" is still available to use as option.

Diagrams:

Incident Issue Description


Number Numbe
r
I-28331, I- 59127, Title: Excel I/O .Net Programmability Support Message is not readable.
27769 58810 Symptoms: If excel interop or excel is not installed on the machine is not giving
enough information about excel interop while clicking on import and export excel
button.
Known workaround: NA
Solution: Required changes have been made and an error message will be
shown if excel interop or excel is not installed on the machine before importing or
exporting any excel file.
I-65248 122107 Title: Crash in Explorer using arrow keys.
Symptoms: When navigating the tree in the design explorer using the arrow
keys on the keyboard, an unhandled exception can occur which crashes the
explorer rendering it unuseable.
Known workaround: Using the mouse to navigate avoids the issue.
Solution: Added additional validation to explorer code to ensure that the explorer
always knows where it is in the tree regardless of method used to navigate.

Engineering:

Incident Issue Description


Number Number
I-40662 66154 Title: Reporter - cannot evaluate environment variables.
Symptoms: When user specifies environment variables in image path and in
calculated field it does not work.
Known workaround: NA
Solution: It is now possible to use PDMS environment variables & calculated
field with PDMS environment variables to specify image path for picture box
image path.
96390 Title: Tags - Excel Export: Wizard - "/" removal for Ref Arrays.
Symptoms: Import and export of referance and element array is getting failed.
Known workaround: NA
Solution: Handling slash is applied to all elements of Ref Array. Earlier it was
applied only to first element.
96394 Title: Tags - Excel Export: Wizard - Default Sheet name for UDET type.
Symptoms: If dbview name contains illegel characters that excel does not
supports in sheet name error message was showing.
Known workaround: Need to strip out illegel characters automatically.
Solution: Illegel characters will be stripped out and rest will be displayed as
sheet name in sheet configuration form.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 439 of 517
Product Release Letter
Incident Issue Description
Number Number
99320 Title: Reporting - Inconsistent results while executing unit tests on SP4 bug fix
branch.
Symptoms: While Running Unit tests via Visual Studio fail sometime due to
VSTestHost.exe running in background.
Known workaround: NA
Solution: Close VSTestHost.exe via task manager if found , Before Running
tests.
I-58550 100613 Title: Tags - Add the number of displayed record when the list is filtered.
Symptoms: Filtered row information is not displayed anywhere.
Known workaround:
Solution: Numbers of records are displayed in the Compare Update element grid
tab when the list is filtered.
I-54992 101126 Title: Tags - Excel Import: Real value's compare logic for excel import.
Symptoms: Comparison of double typed attribute values of importing data and
database was being compared as text instead double.
Known workaround: NA
Solution:
Accept/Reject window will be shown for following scenarios
A)Change in current and revised value with respective to unit conversion of same
dimension.
B)If different unit of same dimension is specified in revised value against unit
specified for current DbAttribute.
C)Invalid dimension unit is specified.
104554 Title: Tags - User fails to delete the row which is moved by using 'Move selected
row up the grid' option.
Symptoms: User fails to delete the row which is moved by using 'Move selected
row up the grid' option in sheet configuration and column configuration window of
the Excel/Export Wizard.
Known workaround: NA
Solution: User can delete moved row in sheet configuration and column
configuration window.
I-59903 104856 Title: Tags - Errors with Equipment 'Name' attribute with Scope by Destination.
Symptoms: Observe that all element NAME attribute values takes the NAME of
the topmost item.
Known workaround: NA
Solution: Current element name has been updated for each item so now user
can see correct name for each item.
I-59922 104904 Title: Tags - Incorrect Link information after comparison scope By destination.
Symptoms: Incorrect link information showing in C/U grid.
Known workaround: NA
Solution: Now correct link information showing in C/U grid.
I-60210 106087 Title: Tags - Missing attributes for Hull Element Types.
Symptoms: Hull element types are missing, so consider as string in comparision.
Known workaround:
Solution: Added a condition to display hull element type.
I-62681 113985 Title: Schematic Model Manager - Button Filter is greyed before the first
compare.
Symptoms: filter button not enable after first comparison, so user can not apply
filter on first comparison.
Known workaround:
Solution: Filter button is enabled after data source is selected i.e before
comparison.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 440 of 517
Product Release Letter
Incident Issue Description
Number Number
114482 Title: Tags - Excel import is not working properly, when the user is importing
empty data cells.
Symptoms: Excel Import is not working properly, when the user is importing
empty data cells is specified in excel. No changes or updates were executed if
user want to update empty value using excel import.
Known workaround: NA
Solution: It is now possible to import empty cell data using Excel Import.
I-63581 116480 Title: Tags - Mutliple match only update first UDET.
Symptoms: In case of multiple matches, only first UDET updated even if multiple
selected. and multiple attributes selected on selection of single element.
Known workaround:
Solution: Selection of element selects and update only attributes of particular
element.
116630 Title: Schematic Model Manager - Remove prompt for filter when no filter
defined.
Symptoms: Message displayed when no filter is applied.
Known workaround:
Solution: Message is removed when no filter defined.
116631 Title: Schematic Model Manager - Change the defaults for updating attributes on
linked items.
Symptoms: By default UpdateMatchedLinked &
UpdateInsertedLinked checkbox's are unchecked in update form.
Known workaround:
Solution: Now by default UpdateMatchedLinked &
UpdateInsertedLinked checkbox's are checked in Update form.
I- 124855 Title: Schematic Model Manager - Performance Issues during comparison and
coloring operations.
Symptoms: Time taken during selecting a configuration or refresh operation was
too much.
Known workaround: No known workaround.
Solution: The time was taken due to side by side grid and also due to
comparison and coloring operation. The performance is improved and is better
than before.

Pipe Fabrication:

Incident Issue Description


Number Number
I-28388 64988 Pipe Sketch Enhancements - Updated Pipe Pieces.
94885 Stop button fails to work in the Galvanization Tank Check form.
I-61269 110438 The Disable SKEY error messages in the modeling consistency check option has
been added to bypass SKEY Error(D820) in the Pipe Fabrication Defaults Form.
I-61271 110766 Title: Added Option for Bolting Message.
Symptoms: When validation pipe spools, the bolting messages are shown.
Known workaround:
Solution: The Disable Bolting error messages in Pipe Spool Validation option
has added to bypass the bolting error in the Pipe Fabrication Defaults form.
I-59801 116747 Title: Cut Information Table for Elbow.
Symptoms: When create pipe spool drawing, there is no cut information table for
elbow.
Known workaround:
Solution: Program modified to created cut information table.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 441 of 517
Product Release Letter
Incident Issue Description
Number Number
I-59062 120295 Title: Adding Popup menu for assigning minimum feed excess.
Symptoms: When validate pipe spools, there is no popup menu for assigning
minimum feed excess.
Known workaround:
Solution: Program modified to add popup menu for assigning minimum feed
excess.
I-65388 124821 Title: End Point Table from RSO.
Symptoms: The coodinates in the End Point Table cannot represented from
RSO.
Known workaround: None.
Solution: Program modified to get coodinates from RSO.

Outfitting:

Incident Issue Description


Number Number
I-52746 87104 Title: HVAC - Provide a GUI to define the TAIL of an HVAC BRANCH
Symptoms:
Known workaround:
Solution: Position Tail Explicit now allows setting of tail attributes TBORE TDIR
etc.
I-53152 87783 Title: HVAC - There is no way to cancel the ADD/REMOVE spool elements
process.
Symptoms: No way to de-select first pick.
Known workaround: Previously - Use Undo.
Solution: 1. allow select/deselect (a first pick will select, a second pick will
deselect a third pick will select etc).
2. Higlighting of spool is updated correctly.
I-53157 88181 Title: HVAC - Spool names for removed elements is not maintaining convention.
Symptoms: Unnamed spools.
Known workaround: Previous was autoname after.
Solution: Option the name added.
I-61522 110447 Title: Report Designer Script Command(Convert.ToDouble) error.
Symptoms: If user specify invalid string for conversion to double in script.
Known workaround: NA
Solution: Defect reproduced due to conversion from invalid string to double.
Script exception is handled inside application and error message is displayed
when any script exception occurs.
I-62957 114715 Title: Piping - Search Utility Enhanced filtering of Element attributes.
Symptoms: Cannot find set of required elements that match criteria.
Known workaround: Search for all, add a column for the attribute and sort by
the column.
Solution: New search options added.
I-64371 118619 Piping - Production of Bending Data.
I-64461 119028 Title: Attribute was being processed incorrectly by PML2
Symptoms: Q VAR !!CE.GAPS or Q VAR !!CE.ATTRIBUTE('GAPS') report an
error (2,800).
Workaround: Handle this error and use Q GAPS syntax
Solution: Definition of Gaps attribute has been corrected to be a Real Array
(DBARRATT). Any temporary workarounds can be removed.
I-64226 119264 Draft - DXF DWG configurable – Problems to export arrow pipe flow.
121186 Title: Design - BPFITT doesn't work with clashing.
Symptoms: No clashing between BFITT and other elements.
Known workaround: No known workaround exists.
Solution: Corrected so also BFITT elements are clashed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 442 of 517
Product Release Letter
Incident Issue Description
Number Number
I-65842 124167 Title: Compare/Update: Improve import of information for Cable Catalogue
Symptoms: Message displayed is not proper for external datasource while tried
to edit configuration.
Known workaround: No known workaround.S
Solution: Earlier message is changed to "Selected configuration is protected for
changes, only filter and attribute mapping can be changed” .
124871 Title: Admin (including Lexicon & Propcon) - Integrity Checker (DICE) patching
lost buckets fails for most databases.
Symptoms: "Attempt to patch failed" message appears and patch is
unsuccessful.
Known workaround: None
Solution: Corrected.
I-62683 124954 Title: Attribute was being processed incorrectly by PML2
Symptoms: Q VAR !!CE.GAPS or Q VAR !!CE.ATTRIBUTE('GAPS') report an
error (2,800).
Workaround: Handle this error and use Q GAPS syntax.
Solution: Definition of Gaps attribute has been corrected to be a Real Array
(DBARRATT). Any temporary workarounds can be removed.
I-56694 125917 Title: HVAC - Incorrect selection of a size not found in the current SPEC.
Symptoms: UD Fittings form still creates fitting whereas standard forms would
prevent creation (inconsistent).
Known workaround: Previously - delete fitting.
Solution: UD Fittings form behaves consistant to standard forms and prevents
fitting creation when spec range invalid.
I-66615 126911 Title: Correction to eccentric circular arcs.
Symptoms: Some circular arcs in hidden-line views were being drawn with their
centres displaced slightly (12.1SP2 and earlier versions are unaffected).
Known workaround: reduce view arc tolerance ATOL attribute.
Solution: A fix has been made to improve the fitting of circular arcs in the
hidden-line output; previously it was possible for large arcs which formed the
major part of a circle to be positioned slightly off-centre thanks to an artefact of
the facetting and approximation process.
127047 Title: Draft - Linestyles with glyphs not correctly exported
Known workaround: N/A
Solution: Program modified to handle user defined linestyles having system
glyphs( 1 to 25 ) and it works for decmode 3 only. The Quivira font needs to be
installed to provide support for glyphs.
Quivira is a free Unicode font in the Open Type format .
User can directly download from following link and install or copy in
“C:\Windows\Fonts”.
http://www.quivira-font.com/
127163 Title: Error message popping up saying "Selected Configuration is not editable"
when tried to edit cable configuration.
Symptoms: Message displayed is not proper for external datasource while tried
to edit configuration.
Known workaround: None.
Solution: Earlier message is changed to "Selected configuration is protected for
changes, only filter and attribute mapping can be changed”.
127954 Title: AVEVA Cache Service - integrity errors can occur if any individual cache
file exceeds 2GB (1,048,575 pages).
Symptoms: Database integrity errors can appear if any individual cache file
exceeds 2GB (1,048,575 pages).
Known workaround: De-activate Cache Service or clear cache contents for the
project experiencing errors, using Cache Manager tool.
Solution: Fix to Cache Service.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 443 of 517
Product Release Letter
Incident Issue Description
Number Number
127967 Database and Data Management - Dabacon Performance enhancement, read
multiple pages in one go. For more information se note under List of
Enhancements above.
I-67055 128442 Title: Admin (including Lexicon & Propcon) - Reconfigurer crash with upgraded
System database (created at 11.1).
Symptoms: DICE reports unknown DBNA attribute on STAT element;
Reconfigurer crashes after lots of errors.
Known workaround: Either (1) Reconfigure the System database in 12.0.SP6
before upgrading it or (2) Use REPLICATE SYSTEM to create a fresh system
database from macro.
[Note that after Reconfiguration the System database will have lost its upgrade
status . This can be re-applied using DBUPgrade SYSTEM TO LATEST].
Solution: Requires patch - 12.1.SP4.10 or later.
128683 Title: Ability to use expressions in attribute mapping.
Symptoms: It was not possible to directly map pml expression to attribute values
Known workaround: Use advanced configuration to use pml expressions.
Solution: Source mapping column in attribute mapping screen can now
understand pml expression as expression and its value will be evaluated and
mapped to destination attribute.

12.1.SP4.9:

Database and Data Management:

Incident Issue Description


Number Number
I-61888 111663 Title: Wrong shape in bracket selection form.
Symptoms: Specifying a symbol in the bracket setup does not use the specified
symbol in the set-up drawing.
Known workaround: Manually change the picture in the set-up drawing.
Solution: Corrected so if the symbol defined in the /SYMBOL attribute exists, it
will be used.

Initial Design:

Incident Issue Description


Number Number
I-40519 69546 Title: Damage Summary Range Column in loading conditions is often all zero
Symptoms: The damage summary report is often returning zeroes in the range
column.
Known workaround: No known workaround exists
Solution: The damage summary table did not use the actual values as calculated
when checking the criteria sets for each damage case, instead a "standard" setup
were used. This had the effect that there were either some slight deviations from
the "true" values calculated for each damage case or the values became 0. For
the range column a 0 result were common, this because the chosen method were
best suited for an intact case with an upright equilibrium.
With the changes the damage summary table will for all cases when it with
success has calculated a criteria value for range, max GZ and area under GZ-
curve write that to the damage summary table. If the criteria set does not contain
a check for any of them it will fall back to the old way of calculating the values.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 444 of 517
Product Release Letter
Incident Issue Description
Number Number
I-61791, 111372, Title: Damage Stability Results reported in Loading Conditions Inconsistent.
I-40519, 69546, Symptoms: The damage summary report is often returning zeroes in the range
I-64207 119029 column.
Known workaround: No known workaround exists
Solution: The damage summary table did not use the actual values as calculated
when checking the criteria sets for each damage case, instead a "standard" setup
were used. This had the effect that there were either some slight deviations from
the "true" values calculated for each damage case or the values became 0. For
the range column a 0 result were common, this because the chosen method were
best suited for an intact case with an upright equilibrium.
With the changes the damage summary table will for all cases when it with
success has calculated a criteria value for range, max GZ and area under GZ-
curve write that to the damage summary table. If the criteria set does not contain
a check for any of them it will fall back to the old way of calculating the values.
I-64584 122552 Title: Shape of additional surface in “Hulldesign”.
Symptoms: Some parts of a surface released from Initial Design, Surface, is
missing.
Known workaround: No known workaround exists.
Solution: Corrected so the released surface will be fully included in the project.
I-65504 122930 Title: Deterministic Stability not calculating Condition KG correctly with a shift
moment fluid load
Symptoms: The issue stems from the fact that the ship uses a stabiliser tank and
requires the use of Shift Moment FSM calculation. The calculations are working
correctly in the loading condition but when the same load group is included as
‘Deadweight available for loss’ the GZ curve produced is more than twice the size
of that in the original Loading condition for the same initial conditions. This does
not happen if the stabiliser is in the load group as fixed or max FSM.
Known workaround: No known workaround exists
Solution: When using the "Deadweight available for loss" option in deterministic
calculations and assigning a loading condition using compartments with shift
moment option for calculating free surface moment the resulting VCG for the
condition turned out incorrect. This is now corrected.

Planar Hull:

Incident Issue Description


Number Number
I-11477 54002 Title: BCBR bracket needs new notch.
Symptoms: Defining notch C (NOC) in the bracket BCBR will not be included in
the bracket.
Known workaround: No known workaround exists.
Solution: NOC is correctly handled and the notch will be added to the bracket.
I-24903 68796 Title: Hope to be change to T value on Point.
Symptoms: When making a topology point as intersection, where the second
definition is a UVT line, the T is always presented as just T when it should be T2
(in combination with U2, V2).
Known workaround: Manually change the T to T2.
Solution: The Statement Wizard will correctly define T2 in the UVT definition.
I-25948 68854 Title: Defined Ident line is gone after Apply and Deactivate.
Symptoms: If defining any text in the Panel component in the Statement Wizard,
the text is in the schema later on set to the Panel name.
Known workaround: No known workaround exists.
Solution: Corrected so the defined text will remain in the Planar Panel Schema.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 445 of 517
Product Release Letter
Incident Issue Description
Number Number
I-54532 90884 Title: Marking functionality enhancement.
Symptoms: Difficult to make text marking.
Known workaround: Using contours to describe text.
Solution: New "Text" is introduced to the MAR statement in Hull Design. For more
details refer to section List of Enhancements above.
I-60527 107140 Title: Improve handling of brackets in symbolic view (NOBRKT1).
Symptoms: Brackets are still in the symbolic view also when the default keywords
NOBKT1 and NOBKT2 is defined.
Known workaround: No known workaround exists.
Solution: Brackets will not be displayed in symbolic views if NOBKT1 (trace line)
or NOBKT2 (plane views) are defined.
I-61737 111279 Title: Generation of bracket between 2 flanges fails.
Symptoms: Combination where bracket syntax 3 is used with two flanges and
another of flanges is curved fails to message: "Insufficient/Irrelevant (side?) info
for bracket".
Known workaround: No known workaround exists.
Solution: Corrected so it is possible to create a syntax 3 bracket between two
flanges, where one flange is curved.
I-61914 111740 Title: Statement error for BVS.
Symptoms: Mixing sides with number and side in the bevel side definition of
stiffener ends does not go through the schema interpretation.
Known workaround: Avoid the mix with number and side.
Solution: This is defined by the Statement wizard. It is now changed so that the
numbers 1 and -1 for Material and Mould side is changed into the keywords MOU
and NMO (Mould and NonMould side).
I-62088, 112210, Title: Creating a topological point at flange end, the profile reference (F1) is
I-61967 111996 changed to stiffener reference (S1).
Symptoms: When indicating a flange end to define a topological point, the
Statement Wizard changes the reference to be a Stiffener reference instead.
Known workaround: Manually in the schema change to the correct flange
reference.
Solution: Corrected so that the Flange reference remains.
I-62813 114345 Title: Even if the overlap <NO=1>&<NO=1>, It is performed without Error
(marking stmt).
Symptoms: Creating a marking with the MAR statement where the marking
already exists will overwrite the already existing marking.
Known workaround: Manually check that not the same number, NO, is used in
the marking statements.
Solution: Marking is checked so it is not overwriting already created marking. Also
next available marking number is presented by the statement wizard.
I-63934 117334 Title: Ppanparts is not working with KN-panel on SB-side. (Fatal Error).
Symptoms: A knuckled panel defined on Starboard side gives fatal error when
trying to run ppanparts.
Known workaround: No known workaround exists.
Solution: Correction made so that the SB panel also can be split.
I-64554 119305 Title: Copy and Paste of hull elements within design explorer.
Symptoms: In the Design Explorer, it is possible to use the Drag and Drop
function on Hull elements. When doing that, the copied element cannot be used
and it cannot be deleted.
Known workaround: No known workaround exists.
Solution: The possibility to wrongly copy/paste and move/copy by drag and drop
of Hull Design specific elements in the design explorer is now prohibited.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 446 of 517
Product Release Letter
Incident Issue Description
Number Number
I-64641 119492 Title: If SID=TOP is given, Point Position of Profile cross is wrong with curved
flange.
Symptoms: Topology Points position for penetrating Curved Flanges, using
SID=TOP is not correct.
Known workaround: No known workaround exists.
Solution: Topology point position will be correctly placed also for Curved Flanges.
I-65517 122983 Title: Shell profiles appearing in wrong location in Symbolic View.
Symptoms: Shell profile is not correct in planar view.
Known workaround: No known workaround exists.
Solution: This can happen when the profile trace is described as a 3D curve. The
problem is handled and the Shell profile will be displayed correctly.

Curved Hull:

Incident Issue Description


Number Number
I-8596 57829 Title: 'Curved stiffener' Type is not support to MarModel Class.
Symptoms: In the class KcsModel, the API will not recognize the type "curved
stiffener".
Known workaround: No known workaround exists.
Solution: Corrected so that the type "curved stiffener" will be recognized.
I-48081 74681 Title: Shell Expansion view horizontal ruler
Symptoms: In the function Position Ruler, it is possible to choose Base Line and
Longitudinal position rulers. This is not relevant for a Shell Expansion View.
Known workaround: As long as the user is aware that those rulers are not
relevant for the view, there is no problem.
Solution: The choices that are not relevant for the Shell Expansion View are now
greyed out.
I-48414 76378 Title: Escape key does not work when create a shell plate.
Symptoms: Pressing the ESC key will in most cases close the form but for Shell
Plates this does not happen.
Known workaround: Close the form by pressing Cancel.
Solution: Form is corrected to handle ESC as Cancel (same as for other forms).
I-52028 87007 Title: Highlight shell profile
Symptoms: Dimensioning in the Curved Panel View is not highlighting shell
stiffeners as a confirmation of successful selection.
Known workaround: No known workaround exists.
Solution: Shell Stiffeners in Curved Panel Views will be highlighted when
indicated, using the Dimensioning function.
I-60070 105503 Title: Closed shell plate shaded error.
Symptoms: Modifying the thickness of a plate in the bulb area is not visualized.
Known workaround: No known workaround exists. The manufacturing part is
however, correct.
Solution: Corrected so that the change of thickness is also displayed in the
shaded view.
112569 Title: Shell Plate names are not appearing for Properties in Curved Hull.
Symptoms: In an "Input Model" view, indicating in View properties, the names of
Shell Plates are not displayed.
Known workaround: No known workaround exists.
Solution: Corrected so that the Shell Plate names are displayed in the view when
requested.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 447 of 517
Product Release Letter
Incident Issue Description
Number Number
I-62981 114757 Title: Longi split error - cannot recognize plate thickness.
Symptoms: Splitting a Shell Stiffener on Starboard side against a symmetrical
defined Planar Panel does not take the correct plate thickness into consideration.
Known workaround: Manually adjust angles after split.
Solution: Corrected so that the correct plate in the panel is used to split the Shell
Stiffener.
I-64094 117695 Title: Cplate cannot be added to cpanel.
Symptoms: Adding a Shell Plate to an existing Curved Panel on an additional
surface may give a warning about wrong block box and not adding the plate.
Known workaround: No known workaround exists.
Solution: Corrected so the Shell Plate can be added.
I-64442 118901 Title: Setting plate PosNo via marAPI.
Symptoms: Can't set PosNo for the reflected instance of a symmetric plate.
Known workaround: No known workaround exists.
Solution: Use the new methods:
MarChm.PlatePropGetExt( MarModel^ plateObj, System::String^ Side)
and
MarChm.PlatePropSetExt( MarModel^ plateObj, MarShPlateProp^
ShPlatePropObj, System::String^ Side)
I-64620 119471 Title: Inithull, hullref, tick box for free naming need to be off by default.
Symptoms: In a new project, the first time the Hull Reference Object is to be
created in Inithull, the tick box for free naming of seams and shell profiles might
be ticked as a default value. If this is not what is desired in the project, it is very
easy to miss.
Known workaround: Make sure the tick box in unticked.
Solution: A minor enhancement in Inithull has been done to prevent the tickbox to
be ticked by default.
I-65231 122075 Title: Displayed cross-section of ShellProfile is duplicated.
Symptoms: Cross section of a Shell Profile in a Symbolic View is duplicated.
Known workaround: No known workaround exists.
Solution: Resolved so no duplicates are presented.
I-65606 123380 Title: Shrinkage value missing after running xml file for curved panel.
Symptoms: Shrinkage defined in an XML input schema is not handled in the
interactive application.
Known workaround: Make sure all four shrinkage parameters are defined in the
XML schema (Ex. <Shrinkage Long="1" LongPartition="1000" Trans="0"
TransPartition="0"/>)
Solution: Corrected so that only valid parameters need to be defined.

Hull Structural Design:

Incident Issue Description


Number Number
I-28577 68973 Title: The shape of hullmark is strange.
Symptoms: A complex Hullmarking gets incomplete plates.
Known workaround: Redo the hullmark text by creating it from a true type font, or
get a representation which is not built on line segments
Solution: A message is added, "To many segments, divide into parts or reduce
segments (max 940)" to inform that the Hullmark is too complex.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 448 of 517
Product Release Letter
Incident Issue Description
Number Number
I-44537 69842 Title: Problem in Boundary Wizard
Symptoms: System aborts when, in Boundary Wizard, is indicating a shell profile
cross section as boundary.
Known workaround: This is only valid for projects using the free naming option for
shell profiles. No known workaround exists.
Solution: The error is handled and it is possible to pick shell profile cross sections
as boundary also in projects using the option for free naming of shell profiles.
I-64778 121276 Title: It has a problem that Hull Steel Export by XML.
Symptoms: Exporting with "Hull Steel Export" a Curved Panel with more than one
plate in a project where Free naming of seams and shell profiles are defined, fails
to export correctly.
Known workaround: No known workaround exists.
Solution: Corrected so all plates in the curved Panel will be exported into the XML
file.
I-64777 122549 Title: Knuckled stiffener in symbolic view.
Symptoms: A penetrating stiffener, defined with a curve, is not shown in the
section view.
Known workaround: No known workaround exists.
Solution: Corrected so the cross-section view of a stiffener defined with a curve is
also displayed in the section view.

Hull Production:

Incident Issue Description


Number Number
I-60396 106627 Title: OSP is causing invalid element.
Symptoms: In the function "Generate Parts" for a Bent Plate and by using an
incorrect view type and style (so that no neg. primitives are displayed), an invalid
element is created.
Known workaround: Make sure a correct viewtype is used.
Solution: Corrected so the invalid element is no longer created.
I-62809 114339 Title: Flange Marking is disappearing with hang.
Symptoms: Markings of a welded flange that is defined with hang (UNS) is not
correctly marked.
Known workaround: No known workaround exists
Solution: Marking of a flange with hang (UNS) is presented correctly.
I-63125 115558 Title: Wrong production information in nesting.
Symptoms: Adding a fitting to a Bent Plate that goes through a hole in the plate
will generate a double hole (a hole inside the hole). This in turn will make nesting
to add start also to this inner hole.
Known workaround: Manually make sure that no start is added to the inner
contour.
Solution: The hole inside a hole is removed from the manufacturing plate.
I-63444 116201 Title: The Position of Sight Line is different from the VM11.6.
Symptoms: Some sight line marking missing on flexible templates.
Known workaround: No known workaround exists.
Solution: Corrected so that the sight line will intersect all generated templates.
I-63447 116203 Title: The sight Line(Base frame) is disappearing in sketch.
Symptoms: The sight Line(Base frame) is missing in the sketch.
Known workaround: No known workaround exists.
Solution: Correction has been made for drawing trace curves in the sketch.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 449 of 517
Product Release Letter
Incident Issue Description
Number Number
I-63363 1183744 Title: Assembly Profiles Output Files.
Symptoms: The function Assembly-Profiles generate to list files, one for profiles
and one for plates. Both files should have the same nesting name in filename.
The message window writes the right filenames but the created files differ from
the message.
Known workaround: No known workaround exists.
Solution: Correct filenames will be used.
I-63360 118532 Title: PLCM crashes when insert drawing form
Symptoms: PLCM crashes when insert drawing form with error message: A fatal
error has been detected. The program must exit.
Known workaround: No known workaround exists.
Solution: The error has been corrected and the Drawing Form will be presented.
I-63362 118533 Title: PLCM crashes when transform part.
Symptoms: General PLCM opens an assembly-part with auxiliary corner hooks. If
you try to move the part without deleting these hooks the program crashes.
Known workaround: No known workaround exists.
Solution: Corrected so it is possible to move the part including the corner hooks.
I-65016, 121166, Title: Shell plate marking is meandering in parallel position.
I-65017 121167 Symptoms: Straight marking on Shell Plates are meandering.
Known workaround: No known workaround exists.
Solution: The markings are corrected and the meandering is removed.
I-65571 123226 Title: Marking are not fully displayed in Plate parts.
Symptoms: Markinglines are missing on Curved Plates.
Known workaround: No known workaround exists.
Solution: Corrected so the missing markinglines are added.

Hull Nesting:

Incident Issue Description


Number Number
I-60526 107145 Title: In Plate nesting, Partid for marking is not coming automatically in burning
sketch.
Symptoms: In sbh_def_nest2.def, the variable "AUTO_POSNO = Yes" has set.
But Partid for marking is not coming automatically in burning sketch.
Known workaround: No known workaround exists
Solution: Corrected so the variable AUTO_POSNO has the expected behaviour.
I-61133 108964 Title: Nested plate disappears after Nestjob – Rename.
Symptoms: Open any nested plate and rename it (using Plate Nesting - Nestjob -
Rename). After renaming and trying to zoom in the nested plate, it disappears
from the view.
Known workaround: Autoscale will display the Nesting again.
Solution: Corrected so zooming will still display the Nesting.
I-61142 108973 Title: Nested plate objects kept in workspace in drawing.
Symptoms: When returning to Drawing from Nesting, the plate parts used are still
in internal memory. This will give error when trying to insert plate parts in the
drawing.
Known workaround: Use the function "Clean Workspace" after returning to
Drawing.
Solution: When returning to Drawing from Nesting, All parts used in the nesting
will be removed from the internal memory.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 450 of 517
Product Release Letter
Incident Issue Description
Number Number
I-61346 110132 Title: Incorrect message output on storing nest
Symptoms: Not possible to store a Plate Nesting with no parts added. The
message “The Nesting PPI must be used to create standard plates” is shown in
the message window.
Known workaround: Add a part, then the nesting can be saved.
Solution: The Nesting module is changed to allow empty nestings to be saved for
later use.
110141 Title: Assembly program allowing any names (capital and lowercase letters) but
Nesting application accept only capital letters.
Symptoms: Nesting only accepts capital letters in the Plate Part Selection form.
Known workaround: Only use capital letters in Assembly names.
Solution: Form is corrected to accept mixed capital and lowercase letters.
I-61032 113925 Title: How to switch off the border of Part name?
Symptoms: When adding partnames to the nesting sketch, they are always
surrounded by a border.
Known workaround: Manually delete the border.
Solution: By setting the nesting default parameter AUTO_POSNO_PART to -1,
no border will be presented in the note.
I-64529 119220 Title: Display the prompt message to user when overwrite old nested plate in
batch nesting.
Symptoms: In batch nesting there are no messages or indications that an old
nesting has been overwritten.
Known workaround: No known workaround exists.
Solution: A check has been added so that it is not possible to overwrite an
existing nest. The plugin nesting is aborted when that happens.

Design Reuse:

Incident Issue Description


Number Number
I-40938 65844 Title: CSEAM not available in insert model after import.
Symptoms: Using Design Reuse and importing CSEAM will not be included in the
"Input Model" view.
Known workaround: End the session and start again. The CSEAM will then be
available.
Solution: Corrected so no restart is necessary. CSEAM will be available
immediately.
I-59867 104714 Title: Copy Assist, after import dabacon attributes are not filled
Symptoms: When importing nestings with plate parts, the nestings in MANU
explorer are not showing attribute values.
Known workaround: Open and save the nesting.
Solution: A new program, se034, has been developed to solve the problem. It is
run in batch and simply reads the given nests and then store them again.
Also the error has also been fixed in Copy Assist and the attributes is stored
correctly.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 451 of 517
Product Release Letter
Assembly Planning:

Incident Issue Description


Number Number
I-57908 98158 Title: Error when loading Assembly ADP libraries
Symptoms: The following error message is given in Marine Drafting when trying
to load the Assembly ADP libraries with 'SHOW !!ASSYDBS':
"There has been an error loading the Assembly ADP Library macro. Please
contact your System Administrator"
Known workaround: No known workaround exists.
Solution: Corrected so it is possible to load the Assembly ADP libraries.
I-61901 111664 Title: Assembly auto drawings functionality crash down system.
Symptoms: Recreating an Assembly drawing sometimes abort the system.
Known workaround: No known workaround exists.
Solution: An error was found that caused the system to abort when recreating
symbolic views in an assembly drawing.

Marine Drafting:

Incident Issue Description


Number Number
I-58268 99283 Title: Cannot search for OPEN/DELETE/SAVEAS in Hull Drafting
Symptoms: When searching for drawings and the search string is longer than 26
characters, no drawings are found.
Known workaround: Make sure the search string is shorter than 26 characters.
Solution: Corrected so the search also accepts longer search strings than 26
characters.
I-59142 102659 Title: Incorrect message when deleting via the Drawing Explorer
Symptoms: When using Right Click function Delete in the Drawing Explorer, the
title is not correct in the confirmation window. Also, sometimes it is the data base
reference number that is shown in the window and not the name.
Known workaround: No known workaround exists.
Solution: The title is corrected to "Delete element" and correct name is displayed.
I-61097 108863 Title: DXF 3D error.
Symptoms: In DXF Export, the clips (collar plates) are missing.
Known workaround: No known workaround exists.
Solution: Corrected so also the clips are included in the export.
I-61917 111722 Title: Cannot save drawing with referenced drawing in Marine Drafting SP4.
Symptoms: Fatal Error occurs when started saving the drawing in Marine
Drafting with referenced drawing inside
Known workaround: No known workaround exists.
Solution: Drawings with referenced drawings will be correctly saved.
I-61043 113550 Title: DwgDxfImport function in MarDrafting Class has some limitations.
Symptoms: Drawing name length is limited to 26 characters. Also the Drawing
Type is not handled. The drawing is always imported to the Default drawing type.
Known workaround: No known workaround exists.
Solution: Drawing type is handled and also the Drawing name length is adjusted
to handle longer names.
I-63116 115713 Title: Modifying note symbol for general note not working properly.
Symptoms: Note symbol for general note set to Circle, but while modifying the
general note, leader line will be lost.
Known workaround: No known workaround exists.
Solution: The handling of symbol creation and usage, especially in the Note
function, has been improved.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 452 of 517
Product Release Letter
Incident Issue Description
Number Number
I-64225 118018 Title: Function in Popup menu Selected > Modify General works only after
second attempt.
Symptoms: Giving extra search criteria in the Selected -> Modify general ->
Search Properties form, does not apply to the selection. Everything is still in the
selection.
Known workaround: No known workaround exists.
Solution: The additional properties in the selection will also be applied to the
current selection.
I-64613 119456 Title: Intelligent text ~D stored by five characters, it removes last two characters
of the string.
Symptoms: Intelligent text ~D stored by five characters, it removes last two
characters of the string.
Known workaround: No known workaround exists.
Solution: A problem reading CPS text data, containing data from "alternative
characters set" is now fixed.
I-64545 119459 Title: Can't remove rows from Search Results
Symptoms: Using Right Click function "Remove Selected Rows" does not have
any affect and the rows are maintained.
Known workaround: No known workaround exists.
Solution: Corrected so that the selected rows will be removed by the Right Click
function.
I-65097 121364 Title: When New Drawing, if using backing sheet this is not seen, even assigned.
Symptoms: Open a New drawing, select from the list of drawing form list, a
proper drawing list.
Drawing and sheet are created, sheet have BSRF correctly assigned, but there
is no form within the drawing.
Known workaround: Use the function Insert>Drawing Form or use the command
UPDATE BSHEETS.
Solution: Corrected so proper sheet will be inserted.
I-65150 121591 Title: Cannot query the existence of a drawing from Vitesse.
Symptoms: The API function kcs_draft.dwg_exist() is always returning zero (0).
Known workaround: No known workaround exists.
Solution: The API is corrected and the function kcs_draft.dwg_exist() will return
correct result.
I-65390 122906 Title: In Marine Drafting, after split subpicture, it's lost model information.
Symptoms: When a sub-picture is split onto two sub-pictures, one of them is
losing the model information.
Known workaround: No known workaround exists
Solution: Model subviews, regrouped on geometry level will retain its identity and
thus response to Model Info inquiries, Model Copy and Model View Slice.
However, note that Model/Exchange will accept any left-over of the regrouped
subviews as input and re-evaluate them fully (geometry of regrouped model
subviews will come back).

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 453 of 517
Product Release Letter
Diagrams:

Incident Issue Description


Number Numbe
r
I-49999 80225 Title: Change of Pipe specification.
Symptoms: specification not propagated for line members
Known workaround: Write a PML macro that updates the branches and its
components according to the Pipeline
Solution: When user change pipe specification by “Pipeline properties” then after
dialog confirmation, the system will ask user if the changes should be propagated
to all line members, including branches.
IF answering yes, the system will try to find specification reference for all
elements where the pipe specification has changed. In case the user skips this
process, he can open diagrams where the pipeline is located and execute refit
“manually” on each branch.
I-51708 85286 Title: PDF files can be now exported from PML interface.
Symptoms: Before the enhancement PDF files could only be generated from the
graphical UI.
Known workaround: No known workaround exists.
Solution: Added PMLcallable method to the PMLDiagrams object which can be
used to export diagrams to PDF files with various export settings.

Engineering:

Incident Issue Description


Number Number
92418 Tags - By default the right hand column in the DataGrid should extend to the right
side of the form.
I-58768 101337 Tags - List Configurator.
I-59941 104968 Tags - Save list in TAGS module.
I-60138 105892 Tags - Unhandled Exception when scrolling.
105909 Tags - 3D View window fails to display the selected element name.
106642 Tags - Performance issue when using horizontal scroll in grid.
107537 Tags - Sublist does not disappear when remove a view used as a sublist.
108669 Tags - Performance Issue for Get Work Highlight Changes after Save Work.
108773 Tags - DbDoubleImpl.EvaluateEquals() function is hugely inefficient and causing
significant performance problems for Tags grids.
I-61035 109400 Tags - Engineering is hanging when opening a list for a UDET with status control
associated.
113364 Tags – Performance Improvements:
• Excel export speed increased.
• Open list optimization, opens faster now.
• Multi record edit optimization.
117766 Tags - Elements in sub-list are duplicated after opening list.
117769 Tags - After Clear Filters Command list isn't considered changed so no save
dialog appears when closing.
117798 Tags - Active sublist unexpectedly deactivated.
117814 Tags - Statistical Report window is not refreshed properly.
119432 Tags - Performance issue when scrolling grid.
119433 Tags - Releasing the user claim on a status link.
119441 Tags - Optimize Bold Claimed Elements.
119443 Tags - Align Tags Unit Tests.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 454 of 517
Product Release Letter
Multi-Discipline Supports (MDS):

Incident Issue Description


Number Number
101196 Compensation profile is deleted when changing the template size causes the
width of the crossbar to be too small for the width of the compensation profile. An
error message is now displayed.
123260 Compensating Plates – A check is now made that the compensating plate spec is
in the MDB.

Pipe Fabrication:

Incident Issue Description


Number Number
I-63361 115879 Allow engagement of AutoNaming rules from the Fabrication Check form.
I-63520 116338 Spool Limits – Confirm form terminology changed from Set/Reset to
Add/Remove.
I-64118 117740 Fabrication Checks Form – Sub Menus now indicated by the usual ...
I-64131 117759 Weld Handling – Improved warning when adding weld with a specific gap.
I-64136 117764 Bending Machine Information Form – corrected to read plain end.
I-65239 122181 Corrected view projection for bend in Pipe Spool Sketches.
I-65513 122982 Pipe and fabrication elements no longer left claimed after creating spool
sketches.
I-65373 122987 Bore in inch now shown correctly in MTO table.

Outfitting:

Incident Issue Description


Number Number
I-53492 89552 HVAC – turning angle is now shown on the sketch for all tee parts of all X-
section.
I-51294 89756 Room Manager – No longer requires Concrete Design licence.
I-57884, 98080, Title: Structures – Bent Panel Negative Extrusion corner positive radius not
I-63145 115645 working
Symptoms: On the loop vertex editor, a negative value for radius works, but if the
user enters a positive radius, it appears as a negative radius
Known workaround: No known workaround exists
Solution: Corrected so that positive radius is also handled.
99414 Title: Isodraft - Missing Wall Thicknesses and Abbreviated Descriptions.
Symptoms: These could be missing when the ATTEXTS option was used with a
very large amount of Text.
Solution: Provision made for spaces used in concatenation of text.
I-58382 99665 Title: Piping – Error in Form: "Modify Component Arrive/Leave".
Symptoms: Form shows all points (connection and geometry) for a tee - but it
allows no more then 10.
Solution: Form has been corrected (units related).
I-61527 110452 Title: Draft – rotate Label.
Symptoms: Cannot set the label rotation value to zero.
Known workaround: Set it to 360.
Solution: Form corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 455 of 517
Product Release Letter
Incident Issue Description
Number Number
I-62249 112754 Title: Draft - Linestyles not exporting properly to DXF.
Symptoms: Line types and styles are not shown correctly in AutoCAD
after export.
Known workaround: None.
Solution: Export corrected.
I-62274 112868 Title: Draft – Hatching is distorted when exported via Configurable DXF/DWG.
Symptoms: The hatch pattern on design geometry is incorrect in AutoCAD.
Solution: Export corrected.
I-62451 113447 Title: Isodraft – PTAPs are cutting the pipes.
Symptoms: The PTAP splits the pipe, rather than behaving like an OLET or set-
on tee, with continuous pipe.
Solution: Isodraft corrected.
I-63145, 115645, Title: Structures - Bent Panel Negative Extrusion corner positive radius not
I-57884 98080 working
Symptoms: On the loop vertex editor, a negative value for radius works, but if
entering a positive radius, it appears as a negative radius.
Known workaround: No known workaround exists.
Solution: Corrected so that also positive radius will be handled.
I-63849 117112 Title: Isodraft - Incorrect bolting for wafer components.
Symptoms: Mixed bolting (for example STUD and MACH) does not work.
Solution: Wafer Bolting is now handled correctly.
I-64103 117704 Title: Model Editor on HVAC, implied ducting incorrect.
Symptoms: Implied Duct disappears from the graphics in certain circumstances.
Solution: The program has been corrected.
I-64240 118180 Structures - Bent Panel Fitting Creation and Modification Problem.
I-64444 118932 Title: Structures - Bent Panel Fittings cannot be copied by Create>Copy
Symptoms: Not possible to copy a bent panel fitting using the Create>Copy
menu.
Known workaround: No known workaround exists.
Solution: Corrected so Copy is available for fittings on a Bent Panel.
I-64314 119013 Title: Structures - Bent Panel Fitting Material Reference is Nulref.
Symptoms: Matref attribute is Nulref at first for the creation of the BPFITT
elements and when we try to change it, it gives an error: “Unable to modify the
material of =16884/487 as write access is not available”.
Known workaround: No known workaround exists.
Solution: The MATREF attribute was missing on the BPFITT. This is now added.
I-64663 119651 Title: Draft - Incorrect View Scale Syntax in Intelligent Text Help.
Symptoms: Scale View Num is shown with the same code word as Scale View
Den.
Solution: Scale View Den code word is now correctly shown as #VRAT[2].
121106 Isodraft - NSBC isometrics now work correctly with tees which leave at P3.
I-65138 121565 Title: SYSTEM crash when Querying BRICOG on Component with unknown
ISPEC.
Symptoms: Dabacon Error 10 and SYSTEM crash.
Solution: Pseudo attributes BRICOG and BRIWEI (and PSATTS) no longer crash
if the insulation spec (ISPEC) is an invalid reference.
I-65098 121589 HVAC - Modify > HVAC > Main branch form now properly recognizes a CIRC
duct.
I-65214 121911 Title: Hole manager - Add Pipe/HVAC brings elements from Application World.
Symptoms: The function Add Pipe/HVAC in the Hole Managemnt Utility also
finds pipes and HVAC from Application Worlds.
Solution: APPLDW owned elements are now filtered from the collection.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 456 of 517
Product Release Letter
Incident Issue Description
Number Number
I-65383 122752 Title: Design - Get Ship coordinate for COG.
Symptoms: UTILITIES \ MASS PROPERTIES \ WEIGHT AND CENTRE OF
GRAVITY displays the COG in ENU, not ship coordinates.
Solution: Option added for Ship Positions.
123744
123764 Database and Data Management - Assignment of !!CE from DBREF with UDA
name of more than 13 characters can suffer from stack buffer overrun.
I-65563 123807 Title: Specification Data listing on the User Defined HVAC Fittings form.
Symptoms: SPECs are listed in reference number order, not Database order.
Solution: SPECs are once again listed in Database order.
I-65628 123818 Title: Modify > HVAC > Move by command is doubling the distance in some
cases.
Symptoms: Both the text gadget and the Move By button were causing the move.
Solution: This has been changed as it was confusing to some users.
I-65198 124005 Title: Connecting the "Head Start" to an existing BRANCH Tail does not pick up
the correct AA-AB values.
Symptoms: Position and HREF are correct, but :HXYsize is NOT correct.
Solution: Correction to ensure that :HXYSIZE is set correctly.
I-65149 124006 Title: Incorrect implied ducting coming off a HVAC transition.
Symptoms: Wrong dimension connecting to user defined CIRC to RECT
transition piece.
Solution: Program corrected.
I-65593 124007 Title: Show Local Views option is automatically getting reset.
Symptoms: Caused by Modify > HVAC menu option or Modify CE button on the
HVAC form.
Solution: Program corrected.
I-65803 124378 Title: Incorrect implied ducting when "branch connecting" to an HVAC TEE.
Symptoms: Occurred when DESP[41] was not set on the user defined y branch.
Solution: Program improved.
I-66143, 126313, Title: LINESTYLE ERROR IN DRAFT 12.1SP4.
I-66440 126343 Symptoms: Some user defined linestyles cause the draft session to crash
with FATAL error.
Known workaround: Avoid using a style where the line segment length is less
than DECREPEAT size.
Solution: Program modified to handle line segments where line length was less
than DECREPEAT size.
I-66143, 126556, Title: Unwanted glyphs on dimension lines.
I-66440 126313, Symptoms: Some user defined linestyles have a glyph at the ends.
126343 Known workaround: None.
Solution: Program modified to use system line-style 1 (solid), and not any user
line-style, for terminators.

12.1.SP4.8:

Marine Drafting:

Incident Issue Description


Number Number
I-59387 103616 Title: Insert Model Verification window does not list Outfitting Model type
Symptoms: The Insert Model Verification window is listing all Outfitting objects
with a Model type equal to "PDMS model".
Known workaround: No known workaround exists.
Solution: Correct dicipline will be listed instead of "PDSM model" such as pipe,
struct, cable way, room, ventilation or equipment.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 457 of 517
Product Release Letter
Incident Issue Description
Number Number
I-59388 103623 Title: Insert Model Verification window is not listing by PIPE/HVAC/CWAY.
Symptoms: The Insert Model Verification window is listing PIPE and HVAC
elements by BRANCH, instead of by the parent element.
Known workaround: No known workaround exists.
Solution: The default keyword AUTO_OUTFITTING_LEVEL has been extended
to also affect Insert Model for PIPE/HVAC/CWAY. If this keyword is set,
PIPE/HVAC/CWAY will be presented in the list instead of BRAN.
I-59394 103626 Title: Outfitting is not following limits of Symbolic Views.
Symptoms: When adding Outfitting models to a Hull Symbolic View, the whole
Outfitting object is drawn and not considering the symbolic view restrictions.
Known workaround: No known workaround exists.
Solution: Slicing does not work for outfitting models if view type is wireline or
wireline hidden line (for performance reason). A new keyword
"VIEW_TYPE_HSV" is introduced. The new default can have the same values as
the existing "VIEW_TYPE" default keyword. If you don't set VIEW_TYPE_HSV it
will have the same value as VIEW_TYPE.

Mechanical Equipment Interface:

Incident Defect Description


Number Number
I-65183 121791 Title: Include partnames in STEP files.
Symptoms: Hull partnames are missing in the STEP file.
Known workaround: No known workaround exists.
Solution: A hull part is now named in the STEP file by the name coming from the
attribute PARNAM.

Diagrams:

Incident Issue Description


Number Number
I-62525 113575 Title: Autonaming during Copy-Paste
Symptoms: When you copy and paste elements and least one element
get errors during the auto-naming process (i.e. because of attribute unset),
autonaming stops without any explanation.
For more information and implemented workaround see section Exceptions –
Significant Defects and Recommended Workarounds.
I-64366 118605 Copy of SCAREA.
I-64753, I- 120368, Title: SCAREF value incorrect after copy-paste.
64881 120786 Symptoms: When shapes that belong to an area were copied and pasted to
another area, SCAREF was set improperly.
Known workaround: Move shapes outside area before copying.
Solution: Defect fixed.

Pipe Fabrication:

Incident Issue Description


Number Number
I-60768 108007 Additional line in Assembly Table for ring type flange.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 458 of 517
Product Release Letter
Outfitting:

Incident Issue Description


Number Number
I-53049 88685 General - Toolbar status gets reset too easily.
I-63035, 115040, Title: BPFITT elements cannot be drawn at Draft.
I-64768 120530 Symptoms: Draft doesn’t draw the BPFITT elements on the bend panels
Known workaround: No known workaround exists.
Solution: Issue is fixed to also draw BPFITT elements.
I-63820 117382 Database and Data Management - Error when using COPY ATTRIB between
different element types with reference UDA left at default value.
118939 General - Error message is displayed while trying to login to Hull and Outfitting
12.1.SP4 using Admin 1.2 Project.
I-64643 119541 Isodraft - Isodraft renaming with PREFIXBOREUNITS.

12.1.SP4.7:

Planar Hull:

Incident Issue Description


Number Number
I-34466 69193 Title: Wrong SWAGE presentation
Symptoms: Presenting swages in planar panels created with the SWA statement
is not correct.
Known workaround: No known workaround exists.
Solution: Corrected so that swages are correctly displayed.
I-54868 91780 Title: Wrong SWAGE presentation
Symptoms: Presenting swages in planar panels, created with the SWA statement
is not correct.
Known workaround: No known workaround exists.
Solution: Corrected so that swages are correctly displayed.
I-60143 105896 Title: Shell profile name has been changed from scheme editor after deleting.
Symptoms: Shell profiles that are deleted from the project will get strange
references in cutout statements that refer the missing shell profile.
Known workaround: No known workaround exists.
Solution: The name of the missing shell profile will remain in the cutout reference.
I-61000 108832 Title: Clip problem.
Symptoms: in a symbolic view created with option DRAW_PAN as PLATE, the
system will show error message " %ERROR : DRAWING CLIPS WA201=531"
when creating a cutout with clips (collar plate).
Known workaround: No known workaround exists.
Solution: The cutout/clips are drawn when the cutout statement is run.
I-61464 110363 Title: How to get Painting Area from one side of panel? (Hull Tools > Painting
Areas > ...).
Symptoms: Calculation of the limit is not correct when limit is a surface.
Known workaround: No known workaround exists.
Solution: The limit calculation has been corrected.
I-62038 112105 Title: System error 1005 on limits definition for Painting Area > Surface
calculation (Planar Hull)
Symptoms: System error 1005 is set when using surface as a limit.
Known workaround: In this case, avoid the surface and use other type of limit.
Solution: Corrected so the curves in the surface are handled without giving error
1005.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 459 of 517
Product Release Letter
Incident Issue Description
Number Number
I-62574 113672 Title: Wrong SWAGE presentation.
Symptoms: Presenting swages in planar panels, created with the SWA statement
is not correct.
Known workaround: No known workaround exists.
Solution: Corrected so that swages are correctly displayed.
I-62812 114344 Title: The X coordinate of the U-axis does not change the distance from the
Frame for marking.
Symptoms: When making two points marking with MAR statement in Hull Design,
using UV coordinates, the X-coordinate is not translated into FR term.
Known workaround: No known workaround exists.
Solution: Corrected so the X-coordinate is translated into FR term.
I-64397 118751 Title: SBH_HOLE_GPS is not enabled
Symptoms: In tribon an environment variable SBH_HOLE_GPS was used to
blank/unblank the GPS fields in the Hole Wizard. This variable has no effect in
AVEVA Marine.
Known workaround: If GPS in Holes are to be blanked, it is currently controlled
via SBH_AN_POSNO.
Solution: SBH_HOLE_GPS is reintroduced in the Wizard. If defined, the GPS1 -4
field will be available. If not set, they are set as read only fields.

Curved Hull:

Incident Issue Description


Number Number
I-48309 75491 Title: Curved Panel - Frame Curves Over CL
Symptoms: When making a Curved Panel View and frame curves are requested
into the view and the Curved Panel is a CL panel, only the portside frame curve is
included in the view.
Known workaround: No known workaround exists.
Solution: Corrected so that both sides of the frame curve will be included in the
view.
I-61322 110070 Title: The ANGLE information is not displayed in Bending Templates of
Mandatory.
Symptoms: The column with angle information is missing in the result list of
Bending Templates.
Known workaround: No known workaround available
Solution: The angle information is added to the result list.
I-62652, 113906, Title: The contents of normal Templates is different.
I-62653 113907 Symptoms: The height of upper and lower seams are different compared to
earlier versions.
Known workaround: No known workaround exsits
Solution: A change has been made, now a template in the middle of the template
arrangement is used to get lower and upper seam information.
Name changes of left and right seam to lower and upper seam has been done.
I-63030 115010 Title: Can not be created Curved panel View.
Symptoms: When making a symbolic view of a Curved Panel, first time the
system sets system error 304. If trying a second time, the system sets system
error 6052.
Known workaround: No known workaround exists.
Solution: The error is corrected and the Curved Panel View will be displayed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 460 of 517
Product Release Letter
Hull Structural Design:

Incident Issue Description


Number Number
I-51519, 84852, Title: Decimal Place Rounding Default Table Creation
I-59237 102884 Symptoms: The system is rounding the coordinates in the Frame and
Longitudinal Table in Structural Design.
Known workaround: No known workaround exists
Solution: One decimal will be kept.
I-59953 105213 Title: RSO Renaming Error
.Symptoms: When renaming an RSO, the RSO name will not be updated in
Planar Panel boundary statement.
Known workaround: Manually update the RSO name in the boundary statement.
Solution: Corrected. The new RSO name will also be updated in any boundary
statement.

Hull Production:

Incident Issue Description


Number Number
I-64693, 116283, Title: Improper jigplane is created for the curved panel
I-63561 120141, Symptoms: Jig plane is not correctly calculated.
119208 Known workaround: No known workaround exists.
Solution: The jig plane is correctly calculated.
I-63668 116664 Title: Ppanparts crashes with girders with shrinkage.
Symptoms: Ppanparts may abort if SHR is used in the panel.
Known workaround: No known workaround exists.
Solution: Corrected so that shrinkage is possible to use.

Hull Nesting:

Incident Issue Description


Number Number
I-61860 111519 Title: Wrong postprocessor results for bevel cutting.
Symptoms: Start hook has different bevel angle than following outer countour and
aux function 118 is missing in some corner loops.
Known workaround: No known workaround exists
Solution: The corner loop error is corrected and the bevel in starthooks are also
corrected.
I-62419 113390 Title: Nesting replace text $3089 is set to 0
Symptoms: The nesting replace text for total path time ($3089) is always set to 0.
Known workaround: No known workaround exists.
Solution: The Total Path Time ($3089) will be correctly exchanged in the Nesting
form.

Hull Weld Planning:

Incident Issue Description


Number Number
I-60713 107768 Title: Welds detected twice.
Symptoms: Having small panels inserted in larger holes of other panels may
cause Weld Detection to detect welds twice for profiles on the smaller panel.
Known workaround: No known workaround exists.
Solution: Corrected so weld is only detected once for the profiles.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 461 of 517
Product Release Letter

Marine Drafting:

Incident Issue Description


Number Number
I-30345 62313 Title: When under 1mm 2D primitives created in Hull Drafting will collapse.
Symptoms: When creating an OUTL with "coinciding" vertices (any two vertices
in approx the same position), such vertices will refer to one common PPOS (the
one created for the first created VTRX). If the position is closer than 1 mm, the
system will abort.
Known workaround: Type "TOLERANCE OFF" in the command window.
Solution: Tolerance will be disabled at startup of Marine Drafting (same as for
Draft).
I-50732 82376 Title: Need loosing restriction after changing projection.
Symptoms: After copy of a sub-picture, the 2D restriction window is moved if the
projection in the sub-picture is changed.
Known workaround: Manually re-make the restriction window.
Solution: The restriction window will stay at the same place after change of
projection.
I-57799, 97756, Title: When subpicture Copy/Move the event point disappeared.
I-57799 104073 Symptoms: When copying sub-pictures, the 2D restriction is defined as On. This
makes it inconvenient for using event points in the copied sub-picture.
Known workaround: Manually, after the copying is done, define the 2D restriction
of the new view.
Solution: The 2D restriction will by default be set to Off.
I-57800 97758 Title: When change Project view in Marine Drafting. Model view position was not
same position.
Symptoms: When changing projection on a view in the Marine Drafting canvas,
e.g. in a Pipe Sketch, the model picture is moved to another location in the
drawing.
Known workaround: Manually transform the picture back to its original position.
Solution: Improved so the picture will not move away from the original position in
the drawing. Some added information (such as dimension) may not survive such
operation and needs manual attention.
I-59142 102659 Title: Incorrect message when deleting via the Drawing Explorer.
Symptoms: When using Right Click function Delete in the Drawing Explorer, the
title is not correct in the confirmation window. Also, sometimes it is the data base
reference number that is shown in the window and not the name.
Known workaround: No known workaround exists.
Solution: The title is corrected to "Delete model" and the correct name is
displayed.
I-59143 102660 Title: Incorrect message when exchanging via the Drawing Explorer
Symptoms: When using Right Click function Exchange in the Drawing Explorer,
the title is not correct in the confirmation window. Also, sometimes it is the data
base reference number that is shown in the window and not the name.
Known workaround: No known workaround exists.
Solution: The title is corrected to "Exchange model" and correct name is
displayed.
I-61296 110043 Title: Label, intelli text from file not read fully.
Symptoms: Reading the text definition file, the definition can only consist of one
keyword.
Known workaround: No known workaround exists.
Solution: It is now possible to define statements built by many intelligent text
items e.g. "Flange #TYPE()GE DN#ABOR()".

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 462 of 517
Product Release Letter
Incident Issue Description
Number Number
I-61297 110044 Title: Label in Hull, symbols are not shown.
Symptoms: Using the Label function in Hull Modelling and trying to use the
Symbolic, Select from list will give an error message "Object does not have a
member VAL".
Known workaround: Use Marine Drafting.
Solution: The Symbol Selection form can be shown only in Marine Drafting. It is
not possible to use the form from Hull Design, because it uses drafting specific
PML functionality to display 2D symbols. The fix is only dimming the button
showing Symbol Selection form if application is not Marine Drafting.
I-61298 110048 Title: Label, intelli text window too small.
Symptoms: The window for the intelli text is too small so all information is not
visible.
Known workaround: No known workaround exists.
Solution: Label Intelligent Texts window is now resizable and remembers its size
between sessions.
I-62388 113334 Title: Hatch not appearing in LOGO in ADP drawing.
Symptoms: Hatching failes in Marine Drafting but is ok in Outfitting Draft.
Known workaround: Manually fill in the hatching.
Solution: Corrected so also hatching will be correct in Marine Drafting.
I-62515 113656 Title: Radius dimension text is missing from exported dxf file.
Symptoms: Importing a drawing from a DXF file is missing the radius dimension
values.
Known workaround: Add the dimension manually.
Solution: Corrected so also the radius dimension values are present after
importing the drawing.
I-62942 115210 Title: The function of Hatch Pattern is Created incorrectly
Symptoms: The hatch pattern is missing some parts in the hatching.
Known workaround: This could happen when the geometry is very far from the
origo. Move the contents of the drawing closer to origo.
Solution: Fixed so that hatching procedure will produce correct hatching also
when the geometry is far from origo.
I-63511 116652 Title: Shell Plate names are not appearing for Properties in Curved Hull
Symptoms: In an "Input Model" view, indicating in View properties, the names of
Shell Plates are not displayed.
Known workaround: No known workaround exists.
Solution: Corrected so that the Shell Plate names are displayed in the view when
requested.
I-60965 117080 Title: The Error of dxf import file.
Symptoms: Distance To Plane dimensioning not giving correct result after
regrouping in an imported drawing.
Known workaround: No known workaround exists.
Solution: The dimensioning will give a correct result also after regrouping sub-
pictures in an imported dxf drawing.
I-63840 117083 Title: Subpicture Automatic function is different between 12.0 and 12.1.
Symptoms: Adding geometry/text to a subpicture is adding it to the closest
component rather than the subview.
Known workaround: No known workaround exists.
Solution: A new Drafting default keyword to control the behaviour has been
introduced:
Name:
MODEL_SUBVIEW_AS_AUTO_STRUCTURE_ALLOW
Description:
Controls the protection of model subviews when current structure is selected
automatically
Legal values:
No: Protect model subview (cannot be automatically selected) (as in 12.0)
Yes: Allow automatic selection of model subview (as in 12.1 and system default).

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 463 of 517
Product Release Letter

Engineering:

Incident Issue Description


Number Number
I-62677 113981 Schematic Model Manager - Method Export of object CompareUpdate() is not a
correct csv file. " missing as text delimiter.
117538 Tags - PBS: Dabacon Stack Errors after Get Work in Tags 12.1.SP4.

Cable:

Incident Issue Description


Number Number
I-61606 110781 Memory is not released to the cable AutoRouting runtime.
118114 Memory is not released after binding NETDATASOURCE object to
NETGRIDCONTROL grid.

Pipe Fabrication:

Incident Issue Description


Number Number
I-59292 103203 Pipe Fabrication - Incorrect Error Message.
I-59823 104645 No Feed Excess Applied Error.
I-61774 112606 Dimensions and view orientation in Pipe Sketch if pipe placed not parallell to
main ship axis.
I-63430 116315 45 degree elbows are being identified as cut elbows.

Outfitting:

Incident Issue Description


Number Number
I-53154 87791 HVAC - Highlighting of previously selected spool elements to add is remaining.
I-53156 90005 HVAC - Adding spool elements is failing but there is no error message.
I-57735 97672 HVAC - Problem with HVAC application.
I-58670 101313 HVAC - Highlighting HVAC Branch to split.
I-58979 102434 HVAC - The HVAC Spool Manager is not maintaining VERIFICATION status.
I-60044 105194 A letter is missing on 'Mofify Pipe' form.
I-60295 106397 Draft - Configurable DXF not exporting labels.
I-61414 110238 Database and Data Management - Unable to expunge user process with error (2,
754).
I-61871 111579 Design - Loss of Model Editor increment settings.
115359 Admin (including Lexicon & Propcon - TYPEX errors reported after
DBUPGRADE in Global project.
116104 Admin (including Lexicon & Propcon - Query>Global Status>Communication
Status does not report reason for failure.
117564 General - After logging into PDMS Design Application, both PDMS and
Gateways License is claimed even though AVEVA NET Export feature is not
used.
I-64054 117568 Draft - Draft Error Dimension Definition.
118201 General - No forwards compatibility in diagrams and engineering bat files.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 464 of 517
Product Release Letter
12.1.SP4.6:

Initial Design:

Incident Issue Description


Number Number
I-60884 108141 Title: Unable to perform Stability calculation - Assertion Failed!
Symptoms: When performing stability calculations without Subdivision Length
(Ls) defined a number of assertions will occur and finally the application will
crash.
Known workaround: Define subdivision length in main particulars.
Solution: For most stability analysis the Subdivision length is not needed. The
solution is to avoid all parts of the calculation where subdivision length is used
unless analysis require the subdivision length to be given.
I-61259 110121 Title: Three decimal places for the CoG's in the loading condition report.
Symptoms: The flag state and the classification societies may sometimes turn
this issue into a big deal that in the compartments table in the loading condition
report, LCG,TCG,VCG columns have 2 decimal places.
Known workaround: No known workaround exists.
Solution: The LCG,TCG and VCG have been extended to 3 decimals in the
report.
I-62008 111977 Title: Surface/Compartment crashes when running Section Area Curve Report
Symptoms: Application crashes if sectional area curve is calculated for a volume
that does not extend over Lpp/2, midship area will become 0. The crash then
occurs when trying to calculate prismatic coefficient when the midship area is
used in a division, causing a division by zero.
Known workaround: No known workaround exists.
Solution: The error is corrected to avoid an abnormal abortion of the system.
I-62013 111983 Title: Unable to resolve Hydrostatic Crashes.
Symptoms: A lot of assertions occur, calculation completes if ignore is pressed
for all messages shown.
Known workaround: Always assign a proper subdivision length (Ship data node,
main dimensions), even if it isn't needed.
Solution: Error corrected. Avoiding performing unnecessary calculations which
the project is not set up for when the error occurs.

Planar Hull:

Incident Issue Description


Number Number
I-24491 68772 Title: Cutout for shell profile number 0
Symptoms: It's not possible to indicate shell longitudinal number 0 (L0) when
defining cutouts in Statement Wizard.
Known workaround: Manually add statement for longitudinal number 0 in the
schema.
Solution: Correction made so it is possible to indicate profile L0.
I-48121 74830 Title: The flange of endcut type126(26) is not connected to web correctly.
Symptoms: When using endcut type 126 and defining the a-measure to zero, the
flange is not stopping at the correct position.
Known workaround: No known workaround exists.
Solution: Corrected so the flange will end at correct distance from the web notch,
i.e. zero from the notch.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 465 of 517
Product Release Letter
Incident Issue Description
Number Number
I-48586 76684 Title: The development shape is not correct in 3-Knuckle Panel.
Symptoms: Parts of the knuckled panel might disappear if the knuckle angle is
small, i.e. less than 4 degrees.
Known workaround: No known workaround exists.
Solution: Knuckle angles less than 4 degrees are not smoothed out in volume
representation.
I-48887 77199 Title: It cannot edit the Japanese in Hull Editor.
Symptoms: Input e.g. Japanese characters in the schema such as marking name
in the Marking statement, is not handled correctly in the schema editor.
Known workaround: No known workaround exists.
Solution: The schema editor is corrected to handle Unicode characters in
descriptions.
I-51542 84912 Title: Question does not appear even if the overlap number(TAP).
Symptoms: If the same TAP number is used, no warning is given to the user. This
is happening for all other components.
Known workaround: Carefully see to that not the same TAP number is used more
than once.
Solution: A check is introduced that will warn the user if a TAP number is already
used.
I-52591 86814 Title: The positions of profile cross topology points are wrong.
Symptoms: In case of inclined profiles with varying bevel defined for the trace, the
topological points will not take the variable bevel into consideration and the
positions will not be correct.
Known workaround: No known workaround exists.
Solution: Corrected so that positions of the topological points will take variable
bevel of the profile trace in consideration.
I-53419 90136 Title: DATABASE ERROR 567
Symptoms: If in Outfitting modelling pipes or cable tray and touch some hull item,
the program become not responding and will close down. The message
"Database error 567" is presented in the console window.
Known workaround: Make sure the MOGWLD is writeable by the user.
Solution: Fixed in a way so the MOGWLD is not needed to be writeable by the
user.
I-54532 90884 Title: Marking functionality enhancement
Symptoms: Difficult to make text marking
Known workaround: Using contours to describe text.
Solution: New "Text" is introduced to the MAR statement in Hull Design. Note -
For a complete description please refer to the attachment provided in the
Knowledge Base Item 4997 in AVEVA Helpdesk.
104855 Title: Japanese chars get obfuscated in statement wizard.
Symptoms: Input e.g. Japanese characters in the schema such as marking
name in the Marking statement, is not handled correctly in the schema editor.
Known workaround: No known workaround exists.
Solution: The schema editor is corrected to handle Unicode characters in
descriptions.
I-60573, 107306, Title: Dimensions of up to Notch (For seam) is strange in curved Stiffener.
I-61738 111133 Symptoms: Add curved stiffeners to a planar panel and then add a seam in the
plate that intersects the curved stiffener. If now defining a notch in the stiffener
using the seam as reference, the notch will not be placed correctly at the
intersection between the profile and the seam.
Known workaround: Instead of using the seam as reference, the notch can be
placed with help of a line intersection, e.g. Y=2500.
Solution: The placement of the notch when using seam as reference has been
corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 466 of 517
Product Release Letter
Incident Issue Description
Number Number
I-61137 108968 Title: Bracket stiffener is not able to define
Symptoms: Adding a stiffener to a bracket does not work.
Known workaround: No known workaround exists.
Solution: Corrected so that the stiffener will be added. Rerun the bracket.
I-62085 112207 Title: If used curved flange with Cut1000 and parameter, disappear Endcut on
symbolic view.
Symptoms: Using endcut code 1000 on a curved flange (profile type, flat bar) will
in views show the wrong length.
Known workaround: No known workaround exists.
Solution: Corrected so the curved flange is correctly presented in views if endcut
code 1000 is used.
I-62089 112211 Title: If create point of profile cross, the point position is to be shifted with seam
panel.
Symptoms: Topology point, TOP, on a curved flange is sometimes in the
Statement wizard incorrectly changed to DIS instead.
Known workaround: Manually change DIS to TOP in the schema statement.
Solution: The topological points are no longer shifted.

Curved Hull:

Incident Issue Description


Number Number
I-36712 69311 Title: Interactive Dimensioning function error for curved panel view
Symptoms: Hull Dimensioning could sometimes in a Curved Panel view give
strange measure that is outside of the view.
Known workaround: No known workaround exists.
Solution: Corrected so that the correct dimension will be added to the view.
I-59471 103858 Title: The Hole & Notch of Shell Profile(Symbol) does not appear in the Shell
Expansion View.
Symptoms: Making a Shell Expansion view where shell profiles contain holes
and/or notches, will not show the position of the holes/notches.
Known workaround: no known workaround exists.
Solution: The symbols for the holes/notches will be correctly presented in the
Shell Expansion view.
I-60434 106760 Title: The corner information and Midpoints of corners in baseplane is
disappearing. (NORMAL_TEMPLATE)
Symptoms: The corner information and Midpoints of corners in baseplane is not
printed in the log file.
Known workaround: No known workaround exists.
Solution: If the environment variable SBH_CHECK_BASEPLANE is defined, the
corner information will be printed.
I-60481 107331 Title: Bending templates is not working, fatal error.
Symptoms: Bending template application aborts.
Known workaround: check that more than one frame curve is intersecting the
curved Panel.
Solution: In case of only one frame curve intersecting the Curved Panel, a
message will be presented in the log saying that the settings of frames should be
changed.
"Failed to calculate base plane
Only one frame position is intersecting the curved plate, change settings or
change template type."

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 467 of 517
Product Release Letter
Incident Issue Description
Number Number
I-61347 110134 Title: The X coordinate of the Corner Point does not change the distance from the
Frame.
Symptoms: In the resulting lists from Bending Templates, the X-coordinates are
not translated into frame terms.
Known workaround: No known workaround exists.
Solution: Corrected so X-coordinates will be presented as frame terms.
I-61518 110444 Title: The Frame Number of Bending templates does not show all frames.
Symptoms: Frame numbers above 500 is not shown in the bending template
output list.
Known workaround: No known workaround exists.
Solution: Frame numbers above 500 will also be included in the output list.
I-61936 111777 Title: Curved Hull View, Curved Panel fatal error
Symptoms: Using the function Tools Model View > Change Projection...,
choosing the Z-Y projection, indicating a Curved Panel will make the system to
abort.
Known workaround: No known workaround exists.
Solution: Fixed so the Z-Y project is also successfully displayed.
I-62227, 112655, Title: Holes in 3D View not shown when cpanel over CL
I-62304, 112967, Symptoms: Adding a hole in a Curved Panel that is defined over CL, the hole will
I-62326 113131 not show in the 3D view.
Known workaround: No known workaround exists.
Solution: Corrected so holes in a CL Curved Panel are also displayed in the 3D
view.
I-62229 112667 Title: cplate's edge is shown in 3D view
Symptoms: When displaying shell plates in 3D, also the seams are displayed.
Known workaround: No known workaround exists.
Solution: Seams are now removed from shell plates in 3D shaded views.

Hull Structural Design:

Incident Issue Description


Number Number
I-46384 73681 Title: Making text available for RSO's
Symptoms: No text's available in RSO's made as backdrops in Outfitting
Known workaround: No known workaround exists.
Solution: Text is added as geometry and clearly visible in the backdrop.
Additional problem with limited text length of 25 characters is also handled and is
now extended to 300 characters.
I-59704 104523 Title: Missing references between design and production panels
Symptoms: Run a schema via "Input Scheme" in a Multi View project
(Design/Production panels) will break connections between Design and
Production Panels.
Known workaround: Do not use "Input Scheme" in a Multi View project.
Solution: Generation after Input Scheme cannot be done for a design panel with
production panels. In this state the design panel component has connections to
the ones on the production panel and Input Scheme generation actually creates a
new panel from a scheme file that can be totally different from the stored design
panel.
This is now prevented and an error message given to the user.
Note that scheme generation is of course still possible via the function Get
Scheme.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 468 of 517
Product Release Letter
Incident Issue Description
Number Number
I-59760 104634 Title: Additional seams in Design Panel
Symptoms: In symbolic views all planar seams are drawn. There is a possibility to
hide all seams by setting the Hull Design default NOSEAMS but then no planar
seams will be shown at all. In some drawings, the Design Seams is desired but
not all production seams.
Known workaround: No known workaround exists.
Solution: An additional value to the default NOSEAMS has been introduced. By
setting the value 2 (NOSEAMS=2), only those seams that include the text
"DESIGN" in the comment (COM) in the planar panel will be presented. All other
seams will be hidden.
I-60079 105506 Title: The OK button will be activated when select twice to the envelope.
Symptoms: when making ROS's from backdrops, after giving the RSO Name and
selecting the envelope, the Ok button is not available until a second choice of
Envelope selection is made.
Known workaround: Choose the same envelope twice and the Ok button will be
available.
Solution: A selection of envelope will activate the Ok button directly.
I-60163 105954 Title: New Block Division Ignores minimum settings.
Symptoms: When running the new block division and adding Minimum plate width
= 200mm and minimum stiffener length = 200mm in the Job Setup, after dividing
the panels the resulting panels have plate and stiffeners below these limits.
Known workaround: No known workaround exists.
Solution: Minimum plate width and stiffener length per job are handled.
I-60198 106011 Title: When changing offset of topological point in design panel the production
point fails
Symptoms: Topology points in Design Panels get wrong translation in Production
Panel.
Known workaround: Manual check of topological points in Production Panel.
Solution: Translation of design to production references refined to take the
position of topological points into consideration.
I-61208 109447 Title: Mismatch between design and production panels
Symptoms: modifying both Design Panel and Production Panel at the same time
will make mismatch in the model. Last saved panel will be used.
Known workaround: No known workaround exists.
Solution: In the case of a two-way updated request the user is asked to choose
one of the ways to override the other.
I-61209 109450 Title: Cutouts disappear from production panel after accepting pending updates
Symptoms: Cutouts defined in a Design Panel is removed from the Production
Panel.
Known workaround: No known workaround available.
Solution: Design Panel cutouts are correctly added to the Production Panel.
I-61328 110080 Title: Cannot delete created Hull Marks.
Symptoms: Using the function Hull Tolls --> Hull Mark --> Delete will not give any
possibility to indicate Hull Marks to be deleted.
Known workaround: No known workaround exists.
Solution: Corrected so Hull Marks can be indicated and deleted.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 469 of 517
Product Release Letter
Hull Production:

Incident Issue Description


Number Number
I-48754 76932 Title: The cranked marking of PPIinfo is strange.
Symptoms: A knuckled marking line in a Curved Panel that has a knuckled may
be presented with a rounded corned instead of the sharp corner as expected.
Known workaround: Divide the markingline into two different marking lines, both
ending at the knuckled point.
Solution: The knuckled marking line will be correct marked with the knuckle.
108668 Title: Problem with GSD's positions on plates for flanges in holes
Symptoms: Converting Curved Flanges in Holes into plate parts will place the
GSD on the plate part the flange belongs to, along the outer contour of the plate
instead of placing the GSD at the hole.
Known workaround: No known workaround exists.
Solution: Corrected so that the GSD's are placed correctly at the hole contour.
I-61215 109460 Title: Ppanparts is not working with Tap in the panel. (Fatal Error).
Symptoms: Fata error when running Ppanparts on a panel where a Tap is
defined.
Known workaround: No known workaround exists.
Solution: The error is corrected and the panel will be correctly split including the
Tap.
I-61612 110794 Title: Not possible delete nested profile
Symptoms: File -> Databank -> Delete -> Nested Profiles. Select any of the
nestings and the system report: "....not found in databank"
Known workaround: No known workaround exists
Solution: Function corrected so it is possible to delete Nested Profiles.

Hull Nesting:

Incident Issue Description


Number Number
I-59287 103134 Title: Nesting crashes when copying multiple parts
Symptoms: Using the Nesting function, Transform Parts. When selecting the
parts, using the option to duplicate the parts, the system will abort when the last
part has been selected.
Known workaround: Copy parts one by one.
Solution: Corrected so that multiple parts can be selected and copied in one go.
I-61279 110002 Title: Incorrect burning feedrate
Symptoms: If BURNING_FEEDRATE is set to blank no burning speed is set.
Known workaround: Make sure BURNING_FEEDRATE is defined for the
machine to use.
Solution: If BURNING_FEEDRATE is set to blank, the burning feedrate is always
fetched from the kerf file.

Hull Weld Planning:

Incident Issue Description


Number Number
I-46093 68154 Title: Weld line around the colour plate is missing part.
Symptoms: adding a collar plate that partly overlap the plate, no weld is added
between the collar plate and the cutout edge.
Known workaround: No known workaround exists.
Solution: Weld is also added between the collar plate and the cutout edge.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 470 of 517
Product Release Letter
Incident Issue Description
Number Number
I-50300 80277 Title: The direction or location of created weld lines are incorrect.
Symptoms: Weld line is in a wrong direction at a curved stiffener flange abutting a
welded flange.
Known workaround: No known workaround exists.
Solution: The weld line will be in the correct direction.
104631 Title: Welds are not correct presented in 3D Viewer
Symptoms: Some welds are displayed inside the material.
Known workaround: No known workaround exists.
Solution: Welds that are displayed inside the material needs to be re-calculated
with this hotfix version.
I-60000 105066 Title: Welds are not correct presented in 3D Viewer
Symptoms: Some welds are displayed inside the material.
Known workaround: No known workaround exists.
Solution: Welds that are displayed inside the material needs to be re-calculated
with this hotfix version.
I-60115 105681 Title: Unnecessary welds are added
Symptoms: Weld at Curved Flanges on Planar Panel Boundaries may sometime
give extra welds.
Known workaround: No known workaround exists.
Solution: Corrected so only the part for the Curved Flange will get welds.
I-60776 107879 Title: There is an unnecessary weld line on the notch area.
Symptoms: If the flange is created at a limit which has been defined as a curve
and this curved contains a 'notch', the notch geometry will be included in the weld
geometry.
Known workaround: See Solution
Solution: Model the limit without a curve and add the notch using the notch
statement.

Marine Drafting:

Incident Issue Description


Number Number
I-44488 67550 Title: The 2D symbol created in outfitting draft does not display correctly in
marine drafting.
Symptoms: A 2D symbol, created in outfitting is not displayed when the same
drawing is opened in Marine Drafting.
Known workaround: No known workaround exists.
Solution: Marine Drafting will also display the 2D symbol correct.
I-45277 75465 Title: 2D RESTRICTION
Symptoms: The 2D restriction does not change the size of the view. The view
size is kept its original size also after the restriction is done.
Known workaround: No known workaround exists.
Solution: The problem was that the SIZE attribute of the VIEW element was
sometimes not set properly when setting the 2D restriction in the original view.
This caused the problems when copying to a new view.
It means that the fix will not work for old views that have an incorrect view size
compared to the 2d restriction but it will prevent the problem in future 2d
restriction handling.
I-57499 97067 Title: CE will be changed after zooming drawing.
Symptoms: Setting CE to a View element in the Draft Explorer and then make a
P-point operation will change CE to a sub-ordinate element under the view.
Known workaround: Always manually define CE after each operation.
Solution: Corrected to keep CE after such operation.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 471 of 517
Product Release Letter
Incident Issue Description
Number Number
I-58867 101710 Title: Incorrect Dimension Curved value on each symbolic view
Symptoms: Making the same section views but with different limitation
sometimes causes the curved Dimensioning to present the wrong dimension.
Known workaround: No known workaround exists.
Solution: Corrected so that all dimensions are correct independent of view limits.
I-59139 102656 Title: Drawing Explorer does not maintain highlight if mouse is moved out of
window
Symptoms: One of the features of the Marine Drawing Explorer is that an
element will be highlighted in the graphical views when it is selected in the tree.
This highlighting is immediately turned OFF if the mouse cursor is moved outside
of the Drawing Explorer window.
Known workaround: Keep the cursor inside the Drawing Explorer.
Solution: Highlighting is kept until a new focus of the cursor is demanded.
I-59140 102657 Title: Drawing Explorer does not maintain highlight if mouse is moved out of
window
Symptoms: One of the features of the Marine Drawing Explorer is that an
element will be highlighted in the graphical views when it is selected in the tree.
This highlighting is immediately turned OFF if the mouse cursor is moved outside
of the Drawing Explorer window.
Known workaround: Keep the cursor inside the Drawing Explorer.
Solution: Highlighting is kept until a new focus of the cursor is demanded.
I-59174 102717 Title: The 2D symbol created in outfitting draft does not displayed correctly in
marine drafting.
Symptoms: A 2D symbol, created in outfitting is not displayed when the same
drawing is opened in Marine Drafting.
Known workaround: No known workaround exists.
Solution: Marine Drafting will also display the 2D symbol correct.
I-59393 103621 Title: Unable to change views Properties
Symptoms: View properties in the “Tools-->Model View-->Change Projection”
menu has no effect on the view.
Known workaround: Use Properties in the Right Click menu on the View in the
Drawing Explorer.
Solution: The View Properties in the Change Projection menu is corrected.
I-59392 103624 Title: Shading feature does not work for Outfitting
Symptoms: Having a lot of outfitting models in a 3D view in the Drafting canvas
and then using the shading function, will take long time and no outfitting models
are presented in the shaded view.
Known workaround: No known workaround exists.
Solution: Outfitting models will not be presented in the shading view but are now
excluded from the rendering and will not take up any time.
I-60430 106752 Title: “Alignment” attribute value in GLAB causes a syntax error
Symptoms: Creating a label can cause a syntax error message
Solution: The HHEIGHT command has been reinstated to avoid the error.
I-60490 107013 Title: "Modify > Label > Leader line start position" has error in logic
Symptoms: Labels which have leader line and were created with option “Another
point”, after command “Update Annotations” always remain in the same position
even if the referenced model geometry changes.
Known workaround: No known workaround exists.
Solution: The leader position is stored in APOF attribute which is relative offset
from the label reference point. Update command recalculates the position and in
case the reference point changes then label leader start point is repositioned
correctly.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 472 of 517
Product Release Letter
Incident Issue Description
Number Number
I-60510 107058 Title: WCOG via Dimension - WCOG wrong result
Symptoms: If there on symmetrical defined Curved Panel is side specific shell
stiffeners, the weight calculation in the function "Dimension-->3D-->Weight and
COG" always display the port side weight.
Known workaround: No known workaround exists.
Solution: Side specific shell stiffeners will be considered in the weight calculation
of Curved Panels.
I-60620 107658 Title: Error in DIMSTYLE Table
Symptoms: Exporting and then importing a drawing the error message "Error in
DIMSTYLE Table" is presented.
Known workaround: No known workaround exists.
Solution: The problem is handled and the DIMSTYLE table will be correctly
handled.
I-60956 108465 Title: How to set general note symbol as NONE
Symptoms: In the function "General Note", Single is always ticked in as default.
Known workaround: Manually change to none or Compound.
Solution: A new drafting default keyword is added:
NOTE_SYM_USAGE = NONE / SINGLE (default) / COMPOUND
I-60991 108573 Title: Data extraction problem for drawing.
Symptoms: Using Data Extraction and trying to extract information regarding a
drawing, e.g. DRA ('CURVED-HULL').VIEW(*).NAME, will not return the correct
information. The result is cut of at approximately 26 characters.
Known workaround: No known workaround exists.
Solution: Corrected so that correct full information is returned.
110392 Title: Labels are not working for cstiff, can't pick any p-points
Symptoms: not possible to identify Curved Stiffener ends when defining labels.
Known workaround: No known workaround exists.
Solution: It will be possible to pick also p-points on the CPREND element, for
example when setting a label or creating a dimension.
I-61561 110638 Title: Insert Subpicture function is different in AM 12.0
Symptoms: Using the function "Insert Sub-picture" was in 12.0 highlighting the
previously selected, but in 12.1 this is not the case.
Known workaround: Manually double click on the name in the field to get it
highlighted for simple handling.
Solution: Function modified to act in the same way as in 12.0, i.e. the name in the
"Name" field will be highlighted.
I-61628 110881 Title: Limitation of Character in Revision Description
Symptoms: Using the rule @607 in the drawingform is restricted to 32
characters.
Known workaround: No known workaround exists.
Solution: The maximum length of table texts in drawing form has been extended
to 100 characters.

Diagrams:

Incident Issue Description


Number Number
I-56405, I- 94833, Title: Diaref array is too short.
60465 106994 Symptoms: Number of entries for attribute DIAREF is limited to 50 so it is not
possible to have e.g. 51 secondary equipments.
Known workaround: None.
Solution: Limit of entries for DIAREF has been extended to 500.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 473 of 517
Product Release Letter
Incident Issue Description
Number Number
I-58300 101012 Title: Error while customizing UIC file
Symptoms: Unhandled exception is being thrown when user selects uic file to
customize
Known workaround: Remove DiagramSchematicAiAddin.uic entry in
DiagramsCustomization.xml. It is obsolete and corrupt.
Solution: Remove DiagramSchematicAiAddin.uic entry in
DiagramsCustomization.xml. It is obsolete and corrupt.
I-60720 107728 Title: Search Utility Menu has gone.
Symptoms: The context menu in Search Results in Diagrams didn't match
standard functionality, e.g. Copy/Paste commands were behaving different
than in other modules and Fill Up/Fill Down commands were missing
Known workaround: Edit Diagrams.uic file
Solution: The menu has been changed as follows:
1. "Set as CE" has been renamed to "Navigate To"
2. Following commands has been removed:
- "Attributes"
- "Rename"
- "Delete"
- "Cut"
3. "Copy" and "Paste" commands have been modified and now they are
behaving like in Design
4. "Fill Up" and "Fill Down" commands have been added (also behaving like
in Design).
I-61083 108791 Title: Excel import does not import reference attribute values.
Symptoms: The value of the reference attributes is the same or nulref after
excel import. The value is not the same as the one present in excel for the
attribute.
Known workaround: Update the reference attribute value manually
Solution: Current and revised values of attributes is compared and updated.
112021 Title: Sorting option is needed for PBS Explorer.
Symptoms: Currently there is no option for automatically sort nodes in PBS
Explorer.
Known workaround: Sort collections inside PML functions used for getting
PBS elements. It works, but makes the funcions complicated and affects
performance.
Solution: The funcionality has been added now. The nodes are sorted
alphanumerically by default and it is possible to turn the sorting off using state
command (Aveva.PBSAddin.SortPBSExplorerCommand). All nodes are
sorted or not, it is not possible to sort only selection of nodes. The exception
is for nodes with static texts - it is possible to keep original order even if the
rest of nodes is sorted (controlled by command
Aveva.PBSAddin.SkipStaticTextsCommand). Buttons for both commands are
added to Project->Options->PBS Explorer Options.
113520 Title: Page array is too short.
Symptoms: Number of entries for attribute PAGE is limited to 50 so it is not
possible to have e.g. 51 secondary equipments.
Known workaround: None.
Solution: Limit of entries for PAGE has been extended to 500.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 474 of 517
Product Release Letter
Incident Issue Description
Number Number
114282 Title: Export DWG
Symptoms: When exporting Arc geometry with line rounding set, diagram
export fails. Normally user can not create Arc geometry using GUI, but it
might be created by Visio when line jumping style is set to Arc.
Known workaround:
1) Disable line rounding
2) In case if line rounding can not be disabled, changing line jumping style
from Arc to something else should helps. However, it might be that export
fails anyway.
Solution: After fix diagram with rounded Arc can be exoprted.
114283 Title: Leader line for labels.
Symptoms: Before, part of label's leader line that was under "rectangle" was
visible in DWG but not in Diagrams.
Known workaround: None
Solution: Leader line for labels can be exported to DWG with proper z-order
now.
I-62808 114324 Title: Autonaming during copy with SCAREA.
Symptoms: At the moment the propagated attributes of a SCAREA are set
after the rename step in the copy process. So if the name contains one of the
propagated attributes then the result name is wrong. The naming of the
objects should be done at the very end of the copy process.
Known workaround: Run autonaming again after copy/paste
Solution: Naming of objects is now made at the end of the copy process,
which will make sure that propagated attributes are considered in the
autonaming.

Schematic 3D Integrator:

Incident Issue Description


Number Number
I-61497 110434 The Cmpsts attribute reports 'OK' after comparison reports connection errors.
I-61498 110435 The attribute Cmpsts should display 'Accepted Differences' for items concerned.
I-61513 110440 The Cmpsts attribute is not updated after a 'getwork'.

Engineering:

Incident Issue Description


Number Number
I-59721 104875 Tags - 3D view doesn't show the model after changing the distance of the current
session units.
I-60599 107381 Title: Base element type is dispayed in owner reference browser.
Symptoms: The explorer in owner reference browser displays the base element
type. E.g.: for owner of type MECHTAG, the owner type displayed is ENGITE
Solution: Actual Type is displayed instead of Base Type.
e.g: for MECHTAG type, owner type displayed is :MECHTAG.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 475 of 517
Product Release Letter
Incident Issue Description
Number Number
I-61789 111985, Title: Attribute or Expression Admin filter applied last is applied for all
111368 configuration from same source.
Symptoms: If there are two configurations from same source to a destination,
then the admin filter applied for one configuration gets applied for all
configurations.
Solution: This issue is solved by first comparing the source id along with source
element type . Singleton instance of Logical operator is replaced with a local
instance for each configuration.
NOTE: Expression filter works only on AND operator.

Multi-Discipline Supports (MDS):

Incident Issue Description


Number Number
104703 An error message is displayed while trying to create ‘Additional Gusset’ for the
support XAT 150.

Pipe Fabrication:

Incident Issue Description


Number Number
I-56910 95906 Mitre Bends with single cuts missed off PSPOOL representation.
I-61175 109098 Pipe Production - inconsistent AELRFA when upgrading thru SP's.
I-60858 109966 Argument error when releasing spools.

Outfitting:

Incident Issue Description


Number Number
I-50099 84824 HVAC - How to align a User Defined Fitting with the orientation of a rectangular
branch?
I-53492 89552 HVAC - How to automatically mark the turning angle for tee parts on the sketch?
I-56502 96220 HVAC - Bore vectors are not being considered when drawing implied ducting.
104506 Design - Autocolour user file is not being saved to restore autocolours.
I-59881 104813 General - Fatal error if ending ' or | is missing in import statement.
106279 Design - Unit qualified UWEI values fail to compute with PROPRE UWEI on
TUBD and other PROP DB elements.
I-60755 108541 Draft - Scaling problem when using Configurable DXF/DWG Export Utility in
DRAFT Module.
I-61530 110455 Draft - Delete section-flat in 3D-View and close the form.
I-62338 113189 Title: Draft error when project updated to 12.1.SP4
I-61734 111113 Symptoms: Misplaced dimensions and labels, often outside the view
I-61907 111734 Known workaround: None
I-63159 115686 Solution: A correction has been made to the calculation of pline end/start
I-63333 115763 points. Labels and dimensions on structural elements now appear in the correct
place. Incorrect drawings can by corrected by an "update anno".
111589 Piping - NSBC Graphics picking and rotation is slow on high arc tolerances.
I-62534 113586 Draft - Rename Function Only Allows for 50 Characters.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 476 of 517
Product Release Letter
12.1.SP4.4

Engineering:

Incident Issue Description


Number Number
I-60165 42979 For publishing reports and datasheets, user required to have Adobe 9.3 or older
version installed. Now there is no such limitation, and it is recommended that user
upgrade to the latest version of Adobe Reader.
I-59927 104912 Tags – Compare/Update, Unhandled exception has been handled for Engi to
Engi ruleset.

Outfitting:

Incident Issue Description


Number Number
I-59902 104848 Draft - Use of intelligent text fails - Property data with spaces where part 1 can be
interpreted as a number.
I-49605 106395, Isodraft - PIPE to PIPE Weld rules.
78647
I-61439 110607 Isodraft - Show unit weight in kg/m if quantity in metres.
I-61671 110980 Isodraft - Dimensions used in relation with PIPCAs are wrong.

12.1.SP4.3:

Initial Design:

Incident Issue Description


Number Number
I-59676 104458 Title: Cannot release hull from Surface & compartment
Symptoms: When a surface is created in Inithull, there are problems to release
surfaces from Surface & Compartment
Known workaround: Release first surface from Surface & Compartment
and not in Inithull.
Solution: Fixed in a way that any (Inithull or S&C) can be the first to create the
surface.
I-59764 104551 Title: Crash renaming curve
Symptoms: Renaming curves in Surface & Compartment will abort the system
Known workaround: No known workaround exists.
Solution: Correction is made to allow the renaming of curves.

Planar Hull:

Incident Issue Description


Number Number
I-18234 57242 Title: Endcut connection symbol does not appear in symbolic view if it uses the
UDE.
Symptoms: In symbolic views, when User Defined Endcuts (UDE) are used on
stiffeners, the endcut symbols are missing.
Known workaround: Manually add symbols to the stiffener ends.
Solution: Symbols will be added to stiffener ends also when UDE is used.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 477 of 517
Product Release Letter
Incident Issue Description
Number Number
I-44948 69885 Title: Data type selection do not shown all data types
Symptoms: In the statement wizard, Panel statement, the drop down list of Data
Types gets shorter once a data type in the list has been selected.
Known workaround: No known workaround exists.
Solution: The drop down list will remain with all the defined data types.
I-58994 102019 Title: If changing Hull Editor by mouse, automatically run all the scheme.
Symptoms: When opening the Hull Schema Editor for an existing planar panel,
the last statement will be the current statement. The first statement is expected.
Known workaround: Move manually to the first statement.
Solution: When opening the editor, the first line will be the current line.
I-59165 102725 Title: Limit info. (zmin/zmax) in the Point stmt removed from sch.
Symptoms: When defining topological points in the statement wizard, intersection
with the surface and using limiting box ZMIN and/or ZMAX, the limiting values are
not included in the panel schema.
Known workaround: Manually add the limits in the schema.
Solution: The limiting box will be preserved and included in the panel schema.
I-59280 103079 Title: The flange text information is not display on symbolic view.
Symptoms: The part name on flanges is only presenting the position number
although the GPS strings has been defined.
Known workaround: Modify manually the string to be correct.
Solution: The flange part names will be correctly presented in the symbolic views.
104192 Title: Space between the words is not allowed in panel name while creating the
panel
Symptoms: Giving in the StatementWizard a name that contains a space
character " ", the system should translate this into the underscore character "_".
This does not happen in 12.1.SP4.
Known workaround: Manually replace the space character.
Solution: The space character will be automatically replaced by the system with
the underscore character.
I-59995 105054 Title: NOPROFSECT default does not have any effect
Symptoms: The result of setting default keyword NOPROFSECT should be that
no profile cross sections is visualized in symbolic views. Setting the keyword in
the Hull Design default has no effect and cross section profiles are always
displayed.
Known workaround: It is possible to hide the cross sections by hiding layer 137
and -9001.
Solution: Correction is made so by setting NOPROFSECT, no profile cross
sections will be drawn in the symbolic view.
I-60035 105169 Title: Error when running a scheme, %ERROR : DRAWING PLATES
WA201=6058
Symptoms: When a plate statements contains all four AS1 - AS4 and at least 8 of
the general strings, the system will give error for the plate. If continuing after this,
the system may also freeze.
Known workaround: Use less General strings (not more than 7).
Solution: Correction is done to handle all General strings in the plate statement.
I-60431 106754 Title: Mould Line Presentation is not working correctly
.Symptoms: Changing representation in the symbolic view to Mould line
representation does not have any effect on profiles.
Known workaround: No known workaround exists.
Solution: Corrected so that also profiles will be presented as Mould line
representation.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 478 of 517
Product Release Letter
Curved Hull:

Incident Issue Description


Number Number
I-27412 68911 Title: Functional Descriptions do not work in Curved Modelling
Symptoms: Using the function "Hull Tools-->Functional Descriptions" in Curved
Modelling will result in a message "This command is not available".
Known workaround: The function is available in Structural Design and Planar
Modelling.
Solution: The function is now also available in Curved Modelling.
I-59664 104338 Title: The Marking of Shell profile may appear short When you run View-Create
Symptoms: In symbolic views, the marking of frame positions on Shell Profiles is
short. It should normally be marked across the whole profile but only a short line
indicates the frame position.
Known workaround: trim the marking lines using drafting functions.
Solution: The marking lines will be drawn cross the whole profile.
I-59718 104450 Title: Curved Plate does not colour coding in SB-side.
Symptoms: Shell plates belonging to a Curved Panel should be coloured different
from the plates that is not yet included in a Curved Panel. Starboard specific
plates will not be affected by this and will always be presented with the colour that
indicates that the plate is not in a Curved Panel.
Known workaround: No known workaround exists.
Solution: All plates will follow the same rule that they are coloured differently if
they are included in a Curved Panel.
I-60207 106056 Title: When re-create Shell profile of SB-side, Shape is broken.
Symptoms: If split plane of a SB side shell profile is a planar panel, the shape of
the resulting shell stiffener is corrupted.
Known workaround: Split with a defined plane.
Solution: Correction is made so that the shell stiffener shape will be correct.
I-60260 106328 Title: Critical error on 3D dimension pick on Shell Stiffener end
Symptoms: Using the function 3D dimensioning on a Shell Stiffener where Shell
Plate Compensation is active may give strange error code (
SB-error in wc114d! 1002) and then the system aborts.
Known workaround: No known workaround exists.
Solution: The issue has been corrected and a proper measure will be presented.
I-60320 106567 Title: SF973D(Hull Plate Interface) is not working.(fatal error)
Symptoms: The Hull Plate Interface seems to randomly abort.
Known workaround: The problem has to do with excess so plates with no excess
will not fail.
Solution: The position of excess on edges corrected so that the Plate Interface
will not crash.

Hull Structural Design:

Incident Issue Description


Number Number
I-47899 74354 Title: Body plan text rotation
Symptoms: When adding a frame ruler to the Body Plan View, the frame
numbering gets upside down when the ruler is drawn in certain angles.
Known workaround: Manually turn each frame number text.
Solution: The frame numbers in the ruler in the Body Plan View will all be turned
into a readable angle.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 479 of 517
Product Release Letter
Incident Issue Description
Number Number
I-57363 98387 Title: Increasing system number of Pillar has a problem
Symptoms: When user create second pillar statement wizard doesn’t display next
no unlike creating stiffener.
Known workaround: Ingnore the number and change in the schema file if wrong
number has been used.
Solution: The correct next number will be shown.
I-59669 104372 Title: Need block
Symptoms: When working with RSO's in hull structural design and functional
structure, all structure is saved in the JUMBO block. After that it is possible to
manually move the structure into the correct block.
Known workaround: No known workaround exists.
Solution: The system tries to find a suitable block to save the structure in. If no
suitable block is found, the JUBMO block will be created and structure will be
stored in that block.
I-60250 106282 Title: Critical error on creation of hull symbolic view
Symptoms: If a Doubling Plate is referring to a stored curve and the curve is
missing (in some way removed from db), the system will abort when making
symbolic views.
Known workaround: Make sure the referred curve exists, or make it as an internal
curve in the planar panel with the CUR statement.
Solution: Proper error message will be displayed (Denoted curve object not
found).

Design Reuse:

Incident Issue Description


Number Number
I-41664 66208 Title: DesignReuse, setting for Rename not shown
Symptoms: In the general settings in the open Design Reuse addin the setting for
the rename option is not shown.
Known workaround: No known workaround exists.
Solution: Rename setting now exposed in GUI.
I-59868 104715 Title: Export marine drawings is not correct.
Symptoms: Not possible to import elements containing unnamed owner
structure.
Known workaround: No known workaround exists.
Solution: Unnamed elements will be handled.

Hull Production:

Incident Issue Description


Number Number
I-58582 100808 Title: The Marking of shell plate hangs over the edge with excess(-5).
Symptoms: The rollaxis marking is going outside of the shell plate.
Known workaround: No known workaround exists.
Solution: The marking lines will stop at the shell plate edges.
I-58583 100810 Title: The WEB Marking of flange on curved-panel(SB-side) is reversed in profile
sketch.
Symptoms: Built Starboard shell stiffeners with endcut type 14 gets incorrect
marking of the web on the flange.
Known workaround: No known workaround exists.
Solution: The issue is corrected and the web marking on the flange will be correct
also when endcut type 14 is used.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 480 of 517
Product Release Letter
Incident Issue Description
Number Number
I-59420 103769 Title: To write plate name as drawing name on bending template sketch is not
possible.
Symptoms: The $1008 drawing rule (Plate Name) in Bending Template drawings
does not give correct result.
Known workaround: Manually change the text in the drawing.
Solution: Correction is done to give the correct plate name for the $1008 rule.
I-60669 107517 Title: Ppanparts add marking lines for profiles
Symptoms: Replacing marking line of stiffener, when part of its GSD is outside
the plate part, sometimes fails when STIMARKHOOK is involved.
Known workaround: No known workaround exists.
Solution: The additional markinglines will not be added.

Hull Nesting:

Incident Issue Description


Number Number
104193 Title: The label text is not deleted.
Symptoms: In Nesting, trying to delete a Label Text using the menu function, will
not work. The label text is not recognized.
Known workaround: Using Right click command will work and the label text can
be removed.
Solution: The menu function to delete a label text has been corrected to
recognize the label text.
I-59737, 104486, Title: The label text is not deleted.
I-60072 105493 Symptoms: In Nesting, trying to delete a Label Text using the menu function, will
not work. The label text is not recognized.
Known workaround: Using Right click command will work and the label text can
be removed.
Solution: The menu function to delete a label text has been corrected to
recognize the label text.
I-59747 104520 Title: Not possible store profile
Symptoms: Using the Profile Part Programming function and defining a profile
with the wrong endcut code will give the message "End cut table missing".
Known workaround: This is the wrong message. The message should be
"Undefined endcut code". Correct the endcut definition in the form and continue.
Solution: Correct message will be presented.
I-59789 104587 Title: Framework plate parts in nesting
Symptoms: When plate part from framework is nested, system reports 'Panel not
found'.
Known workaround: Ignore (confirm) message and continue to nest.
Solution: Corrected so that the unnecessary message is removed.
I-60072, 105493, Title: The label text is not deleted.
I-60074 105496 Symptoms: In Nesting, trying to delete a Label Text using the menu function, will
not work. The label text is not recognized.
Known workaround: Using Right click command will work and the label text can
be removed.
Solution: The menu function to delete a label text has been corrected to
recognize the label text.
I-60084 105594 Title: The system error 1005 occurs when checking the bevel.
Symptoms: Nest a part where a limit has variable bevel and then use the
function, Show Production Information. Select Bevel. The error 1005 will then
show up and no bevel will be displayed.
Known workaround: No known workaround exists.
Solution: Corrected so varying bevel will not produce this error and the bevel will
be presented for all limits.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 481 of 517
Product Release Letter
Incident Issue Description
Number Number
I-60286 106360 Title: In nesting, Part selection by assembly is not working.
Symptoms: Selecting plate part, using Assembly as input does not work if the
name is longer than 26 characters.
Known workaround: Make different selection, not using assembly or make sure
assembly name is not longer than 26 characters.
Solution: Assembly selection is now possible and the assembly name may be up
to 1000 characters.
I-60397 106626 Title: Nest can't be stored with restplate.
Symptoms: A Nesting, containing a restplate and placed in a drawing form is not
possible to save.
Known workaround: No known workaround exists.
Solution: Issue is corrected so that all types of nestings can be saved.
110446 Title: One plate nest fail.
Symptoms: One Plate Nest is not ending.
Known workaround: Set nesting default NEST_ADD_DIRTEXT to No.
Solution: Corrected so the process will end with a correct result.

Marine Drafting:

Incident Issue Description


Number Number
I-43255 66974 Title: Detail View (2 CP from Symbolic View) to include Outfitting elements
Symptoms: Using the function Detail View defining the detail with 2 Cursor
positions will not include any Outfitting model.
Known workaround: No known workaround exists.
Solution: The function has been updated to also include Outfitting elements if
they are inside the view definition of the two cursor positions.
I-46380 70110 Title: DXF export - Shell expansion views are always exported to DXF with plate
thickness hatching.
Symptoms: When exporting drawing to DXF, containing a Shell Expansion view,
the hatching is always, independent of view setting, included in the DXF file.
Known workaround: No known workaround exists.
Solution: Hidden information such as thickness hatching in Shell Expansion
views are not exported to the DXF file.
I-52446 86775 Title: Printer in Print Preview
Symptoms: The system always uses, instead of current printer, the default printer
for previewing.
Known workaround: Manually change printer in the Preview window.
Solution: System will remember printer setting.
I-53456 88324 Title: Draw as plate view with swage panel
Symptoms: When Draw code for Hull panels are set to "Plate", swage panels are
not drawn in symbolic views.
Known workaround: No known workaround exists.
Solution: The Swage panels will be included in the symbolic views also when
Draw code is set as "Plate". The wage panel will be draw "As Panel" which is the
same handling as for Knuckled Panels.
I-55198 92351 Title: Dxf exporting font and aspect problem
Symptoms: Exporting in DXF format is not fully handling True Type Fonts.
Known workaround: No known workaround exists.
Solution: TTF is handled properly in DXF export.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 482 of 517
Product Release Letter
Incident Issue Description
Number Number
I-55894 93737 Title: Sloped Dimension Changed In Marine Drafting
Symptoms: Drawings created in Outfitting Drafting, all sloped Dimension is
changed.
Known workaround: Make sure the “Tlindicator” attribute is unchecked and
explicit specify direction of the dimensioning in the “Direction WRT to Owner”
attribute in the LDIM element.
Solution: The sloped dimensions are corrected.
I-56698, 95446, For information see the release note under heading List of Enhancements above.
I-56573, 98558,
I-59100 103784
I-60459 105697, Title: Names of curved hull elements are written in dxf-export.
106879 Symptoms: Import dxf files created by Export dxf will draw normally hidden
information such as object names. Example could be to make a drawing
consisting of a Curved Panel, export the drawing in dxf format and then import
the dxf file again, will show the names of the profiles and plates in the drawing.
Known workaround: Manually hide the information after import.
Solution: Import is corrected to automatically hide such information.
I-60302 106442 Title: Unable to place inside radius dimension on where it should be placed when
radius <= 50mm
Symptoms: Adding for example a corner radius with a radii 50 mm or less and
then use Dimension -- >Radius, will place the measure wrong if indicating on the
concave side of the radius.
Known workaround: Move the arrow, line and measure text manually to the
correct position.
Solution: Corrected. The dimension will be automatically correctly placed.
I-60338 106534 Title: The scale of subpicture had changed which ignored the scale of original
view or default.
Symptoms: When splitting views, the scale of the resulting views is changed to
1:1.
Known workaround: Manually change scales in the views after splitting.
Solution: When splitting a view on geometry level, the transformation history (e.g.
the scale) will be preserved.
I-60459 106879, Title: Names of curved hull elements are written in dxf-export.
105697 Symptoms: Import dxf files created by Export dxf will draw normally hidden
information such as object names. Example could be to make a drawing
consisting of a Curved Panel, export the drawing in dxf format and then import
the dxf file again, will show the names of the profiles and plates in the drawing.
Known workaround: Manually hide the information after import.
Solution: Import is corrected to automatically hide such information.
I-60605 107410 Title: HVAC is not coming in symbolic view after selecting Ventilation in outfit tab.
Symptoms: HVAC is not presented in symbolic views.
Known workaround: No known workaround exists.
Solution: HVACs will be included in symbolic views.

Diagrams:

Incident Issue Description


Number Number
I-50660 81145 Title: Batch Job update shapes in diagrams with UDA name instead of the UDA
description.
Symptoms: When a new UDA is defined having some diagrams defined, the
Batch job command in Diagrams will update the shape data with the UDA name
instead of the UDA description.
Solution: Batch Job now updates UDA name in shape data properly.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 483 of 517
Product Release Letter
Incident Issue Description
Number Number
90924 Method generating folder name has been changed to not add "s" at the end of
Equipment for both schematic and design equipment types.
I-55752 93557 Title: Moving schematic elements to other page of multipage diagram
Symptoms: Cutting and pasting schematic elements from one page to another on
a multi-page diagram will cause the database elements to first be deleted and
then re-created again.
Solution: Support for moving elements between the pages and diagrams has
been added. User will need to select shape (or shapes) and drag them over one
of the ‘page’ tabs on the bottom of Visio drawing. Then just drop the selection on
another page.
97342 Title: Windows available from Admin Tab are visible for regular users after
application start.
Symptoms: If admin-only functionality, such as Design Reuse, Drawing Explorer
and Rules were left open by an admin user, it would still be available for a non-
admin user afterwards .
Solution: Windows of Design Reuse, Drawing Explorer and Rules are now being
hidden when app starts with non-admin user login id.
I-58079, 98670, Title: Copy / paste and session defaults.
Symptoms: When using Copy/Paste, sometimes the user want to use attribute
values from Session Defaults rather than from the copied shape.
Solution: An enhancement has been made, introducing a new option where the
user can determine if copied attributes should be overridden by session defaults
or not.
I-58463 100195 Title: Copy/Paste - verifying Session Defaults.
Symptoms: During Copy/Paste. the user wants to be able to verify the session
default settings without having to cancel the Copy/Paste operation.
Solution: An enhancement has been made, allowing for the Session Defaults
window to be opened and changes during the Copy/Paste operation.
I-58504 100359 Title: Open diagram dialogue displays the same page reference several times.
Symptoms: If a line (which has secondary shapes of itself) has OPC elements
and appears on more than one page, then there are a number of entries on the
Open Diagram dialogue.
Solution: The problem has been fixed.
I-58508 100376 Title: Diagrams batch creation of PDF files.
Symptoms: When we use Batch job to print PDF files, we must choose a print
size and orientation of pages for all diagrams. It would be better if we could have
an option to print with the “Page Setup” parameters defined for each diagrams.
When we use Batch job to print PDF files, we must manually enter the name of
each PDF file. It would be better if batch print automatically create PDF files with
the name of scdiag for example, or with the value of a predefined scdiag attribute.
Solution: Batch Job has been updated with a new export functionality, which will
generate PDF files named as the diagram.
I-58754 103997 New option has been introduced “Diagrams Options->General options->System
Configuration->Concatenate branches”. Basically, it determines if branches that
are in the same line and are connecting together in the same flow should be
merged or not. . Please see updated documentation in chapter Piping &
Instrumentation Diagrams (P&IDs) / Automatic Management of Logical Pipe
Model..
I-59964 104997 Title: Diagrams crashes when customising ribbon.
Symptoms: When using the Customise function to customise the Fluent UI
ribbon, Diagrams crashes when selecting certain customisation files.
Known workaround: Remove the line <CustomizationFile Name="AIAddin"
Path="DiagramSchematicAIAddin.uic" />
From the file DiagramsCustomization.xml
Solution: The problem has been fixed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 484 of 517
Product Release Letter
Incident Issue Description
Number Number
I-60752 107804 Title: Copy / Paste performance
Symptoms: The Copy/Paste operation is experienced as slow when
copying/pasting large portions of data.
Solution: The code has been optimised, resulting in a performance improvement
of up to 30%.
107904 Title: Handling of Unassigned Items
Symptoms: Currently it's not possible to easily assign shapes to a DB element
that has been created from Compare/Update or imported via Excel Import. It's
necessary to have a way of doing this easily so that a complete process workflow
can be achieved.
Solution: Basic handling of unassigned items has been implemented. Please see
updated documentation in chapter Working with Diagrams / Unassigned Items.

Schematic 3D Integrator:

Incident Issue Description


Number Number
I-58722 101295 Project configuration rules to assign attribute values can now use expressions
relating to the target object when it can be certain that object will already exist, for
example to name the target object based on the name of owner of target.
102858 An error condition encountered in build an item of equipment has been corrected.
I-59565 104194 An error condition encountered in comparing a pipeline has been corrected.

Engineering:

Incident Issue Description


Number Number
97838 Tags - Exit from the application works (application is closed correctly) when using
non-tabbed mode.
98148 Tags - New precision icon added for unit-less column.
98150 Tags - Moved "Type of change" column to the left side of the grid and filtered the
rows to show only new, modified or deleted records by default.
98178 Tags - Layout is not destroyed for stacked columns when pin and unpin columns.
98249 Tags - Application works correct when adding reference sublists. There is no
exception anymore.
I-57925 98255 Tags - Modified algorithm for storing categories and lists to prevent renaming lists
or categories to incorrect names.
98788 Tags - List is scrolled to the selected item if user selects a row in message log.
100223 Tags - Column Summaries option (checked/unchecked) is now aligned between
context menu and Ribbon command.
100400 Tags – First column in History window presents value set as Row Id in List
Manager.
I-58552 100615 Tags - Numerical columns are now exported as numbers in Excel.
I-58553 100643 Tags - Reference Browser displays correct UDAs references defined in Lexicon.
I-58559 100670 Tags - Multi Select Filter displays only relevant values based on other filters.
I-58666 101094 Tags - List sort order is being saved when user does SaveWork and is shared
between all users.
101097 Tags - Regional settings for datetime attributes.
101098 Tags – Changed filter conditions to match checkboxes "check policy"
requirements.
101274 Tags - Very slow Tags performance when "Highlight changes after Get Work"
option is enabled.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 485 of 517
Product Release Letter
Incident Issue Description
Number Number
I-58760 101325 Tags - Adjusted long text field editor behaviour to match standard text field
behaviour (after pressing F2 text in long text editor is selected and can be
overwritten).
I-58761 101327 Tags - Cell forward on enter or tab.
I-58765 101331 Tags - No questions when closing Tags if it is not necessary.
101495 Tags - Added Edit button to edit current reference without removing existing and
adding new reference.
Changed layout so Edit, Add and Remove are at the top and Up and Down are
below.
I-59135 102651 Tags - No exception when modifying cells fires an event and change the colour of
modified cell.
103600 Tags - Units are refreshed on active opened list if we modify Unit Set in List
Manager.
103702 Tags - Updated Units of measures are applied on active opened list after
GetWork now.
104416 Tags - Grid is now displayed correctly after Get Work when modify scheme of
database view in Lexicon.
I-60446 106792 Tags - PBS query node was not working as expected but is now corrected.

Multi-Discipline Supports (MDS):

Incident Issue Description


Number Number
I-48608 76705 Wrong support arrangement and other issues with vertical risers on vertical pipes.
I-53065 87609 On FT21, Square/True choice, or Mirror frame cause unknown error.
100807 An error message is displayed while creating the support type XFT-30.
101196 Compensating plate or profile is deleted on changing the framework profile
sizes/templates.
101531 Compensation buttons have been repositioned to be consistent with other forms.

Cable:

Incident Issue Description


Number Number
I-55788 93592 Edit Route points option on cableways using Quick routing does not work.
95566 An Error Message is displayed on Clicking ‘Move Segment’ link in the Move
Cableway Segment form when ‘Re-route Cables’ Checkbox is checked.
96434 User is able to Split the Cableway Branches using ‘split using plane’ even though
it is claimed by another user.
98094 An Improper Error message is displayed on selecting a reference point in the
Route Attachment points create tasks form, when the Route Pointers are created
in the same position.

Outfitting:

Incident Issue Description


Number Number
I-37512 64297 Draft - Insulation and pipe, both shown in hulldrafting? For more information see
release note under heading List of Enhancements above.
I-38451 67307 Draft - Draft Autotagging Error caused by space in BRANCH MEMBERS.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 486 of 517
Product Release Letter
Incident Issue Description
Number Number
94677 Draft - Draw both Pipe & Insulation.
104500 Admin (including Lexicon & Propcon) - When upgrading from 11.6, Reconfigurer
crashes when reconfiguring the Global Database to remove the obsolete PACKF
attribute.
104506 Design - Autocolour user file is not being saved to restore autocolours.
104418 Draft - Fix memory leak in DRA_CSGGeneralElement::createCSGTree().
I-60136 105795 Admin (including Lexicon & Propcon) - Dictionary world member list now
does not get truncated at a REVCWL element.
110086 Database and Data Management - SP4 to cope with Integrator Limit Point ILP*
elements created in E3D2.
I-61600 110813 ExPLANT-A - This was a dll incompatibility and has been corrected.

12.1.SP4.2:

Outfitting:

Incident Issue Description


Number Number
I-59524, 96648, Draft - Problems in DXF/DWG export.
I-59865 97011,
104008,
106332
I-57912 98170 Draft - Diameter Intelligent Text.
I-59247 103981 Draft - Configurable dxf/dwg, fatal error.
I-58627 105065 Draft - Symbolic labels do not export to AutoCAD using configurable DXF/DWG.
I-59865 106332 Draft - Frame and Leader Line not appearing on configurable DXF/DWG output.
I-60295 106397 Draft - Configurable DXF not exporting labels.

12.1.SP4.1:

Initial Design:

Incident Issue Description


Number Number
103226 Title: Data missing in release from Hydrostatics to DABACON.
Symptoms: Not possible to create reports for some Hydrostatics calculations
Known workaround: No known workaround exists.
Solution: Implemented in 12.1.SP4.1. Additional data have been added to db
elements in 12.1.SP4 hotfix 1, it is not possible to use data stored with hotfix 1 in
12.1.SP4.

Planar Hull:

Incident Issue Description


Number Number
58318 Title: Cutout not possible for profile type 11.
Symptoms: Making cutout in a profile type 11 for a penetrating profile will result
in error 612.
Known workaround: No known workaround exists.
Solution: Correction is made to accept cutouts in profile type 11.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 487 of 517
Product Release Letter
Incident Issue Description
Number Number
59345 Title: Side option should not be available while creating markings for PS and SB
panels.
Symptoms: When creating marking on a side specific panel (P, S or SP) the
option Side is available in the Statement Wizard. If a side is chosen, no marking
will be produced.
Known workaround: Do not select any side for marking in the statement wizard
when handling a side specific panel.
Solution: The Side field will be dimmed for side specific panels (P, S and SP
panels).
60002 Title: Unhandled Exception while creating doubling for notch at seam end.
Symptoms: Creating a Doubling for a notch where the notch is defined at a
seam end, on a CL panel may cause the system to an abnormal abortion.
Known workaround: No known workarounds exist.
Solution: The Doubling will be correctly handled and the system will be able to
produce the Doubling.
62734 Title: While modifying the excess side is not set.
Symptoms: In a SBP panel, add excess but only for one of the panels (Valid only
P). When modifying later the excess via the Statement Wizard, the side
information is lost.
Known workaround: Modify the excess statement in the Schema editor.
Solution: The side information is correctly presented in the Statement Wizard.
63104 Title: Problem with creation of an Interpolation Point.
Symptoms: When creating a topology point of type Interpolation, the default
factor is set to zero (0). This is not a realistic factor but a point is still created at
the location of the first point.
Known workaround: Set a valid factor (F=<factor>) in either the schema
statement or in the Interpolation factor field in the Statement Wizard. If the
behaviour to get a point at the same location as the first point, using factor 0 is
desired, another topology point type should be used.
Solution: A default factor of 0.5 will be defined if the point is created via the
Statement Wizard.
I-24591 68783 Title: Notch is created in the wrong position.
Symptoms: In a Starboard specific panel there is an unsymmetric corner notch.
Creating a Doubling for this notch and also create a notch in the doubling for a
seam will cannot be handled by the Statement Wizard.
Known workaround: The reflection keyword, REF, can be added in the schema
editor.
Solution: The reflected seam will be handled correctly.
I-51862, 85638, Title: Problem to use macro clips.
I-56272 94631 Symptoms: If a compiled geometry macro is called, the system will fail.
Known workaround: Make sure all macros are correctly compiled and are of no
zero size.
Solution: Proper message will be displayed and the system will continue.
I-52442 86610 Title: “DEF_QUAL_OUT”on sj001.def is not working correctly.
Symptoms: Defining the default keyword DEF_QUAL_OUT in Hull Modelling will
not have any effect on the schema as described.
Known workaround: No known workaround exists.
Solution: The default quality code will be added in the schema if the keyword is
defined in the Hull Modelling default.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 488 of 517
Product Release Letter
Incident Issue Description
Number Number
I-55466 93010 Title: Colour settings in Sj001 don't work.
Symptoms: The defined colour in the Hull Design default file is not reflected in
the Statement Wizard.
Known workaround: Do not use the default colour setting. See Solution.
Solution: In the statement wizard the latest used colour is saved from the last
run for every part. This makes the use of default colour for parts no longer
necessary and also the two functionalities conflict. The default colour has been
removed.
I-55519 93556 Title: Undefined term BEM.
Symptoms: When defining a Planar Panel in the Statement Wizard in Structural
Design the wrong keyword for Non watertight panel is written in the panel
statement. The keyword BEM is written when it should be NOWT.
Known workaround: Manually change the BEM keyword to NOWT in the
schema editor.
Solution: Correct keyword NOWT will be written in the PAN statement for Non
watertight panels.
I-56454 94960 Title: Wrong profile symbol on bracket
Symptoms: Symbols for flat bars on brackets in a symbolic view shows the
symbol of a HP bar.
Known workaround: No known workaround exists.
Solution: The correct symbol will be shown for a flat bar on brackets.
95461 Title: Modifying multiple stiffeners changes the position number.
Symptoms: When modifying multiple Shell Stiffeners (any modification), the
position number is automatically updated but they all gets the position number of
the first stiffener in the list.
Known workaround: Update one by one Shell Stiffener.
Solution: The issue is corrected.
I-57380 96781 Title: If I using the Named Cut-out cannot create a hole in the clip.
Symptoms: When defining a Cut-out and use a named cutout type, all fields in
the "Clip hole" tab are dimmed.
Known workaround: Add the hole in the clip manually in the planar panel
schema.
Solution: The correct field will be available.
I-56862 97064 Title: There’s a problem with modification of stiffener end bevel.
Symptoms: When adding bevel to a stiffener flange end (no bevel for the web),
the system responds with the message "Undefined term or term in wrong
position".
Known workaround: No known workaround exists.
Solution: The system wrote the wrong information in the bevel side of the
stiffener end for the web part if no bevel is defined for the web. This is now
corrected and if no bevel is defined for the web, only for the flange, UNS will be
written in the bevel side to indicate that this part is undefined e.g.
BVS=UNS:TOP.
I-57620 97329 Title: Incorrect AS value of Bracket Instance.
Symptoms: when defining any of the keywords AS1 to AS4 in the bracket
instance setup, the value of AS1 to AS4 (GPS! to GPS4) all get the value defined
for AS1.
Known workaround: Manually change the values in either the Statement Wizard
or in the panel schema.
Solution: The values will be correctly distributed.
I-57716 97598 Title: Definition of bracket with FACE_PLATE.
Symptoms: When defining brackets that should only contain a face plate (no
stiffeners), stiffener number one will still be added along the free side of the
bracket.
Known workaround: Set PRB to -1, indicating that the second profile should not
be available.
Solution: When only face plate is required, no stiffeners will be applied.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 489 of 517
Product Release Letter
Incident Issue Description
Number Number
98382 Title: The clip data is not getting updated properly.
Symptoms: When using standard clip e.g. 010 and defining a hole in the defined
clip, when modifying, the hole tab is not correctly updated. It is the hole for the
first clip that will be opened up in the wizard but the definition is for the second
clip.
Known workaround: Modification has to be done for the clip in the schema
statement.
Solution: The standard clip code will be properly decoded so that the correct
hole information can be edited.
I-58549 100612 Title: Obsolete default parameters.
Symptoms: The Hull Design Default parameters DRAW_FLA_TEXT,
DRAW_PLATE_TEXT and DRAW_STI_TEXT has no effect at all.
Known workaround: -
Solution: The parameters have been removed.
101499 Title: While modifying existing hullmark, the field 'Angle' takes the value of the
previously modified Hull Mark.
Symptoms: Modifying a Hullmark that was previously defined where the Angle is
defined, this field is not correctly handled. The value that is presented is not the
values given by the original definition.
Known workaround: No known workaround exists.
Solution: The field will be properly handled presenting the valid data.
I-58428 102467 Title: Bracket modifying syntax
Symptoms: When modifying a bracket in the Statement Wizard and changing
the syntax, it is possible to press the Update button. If doing so, a new bracket is
created and the original bracket remains unchanged.
Known workaround: Modify bracket in the schema file.
Solution: Update a bracket in the Statement Wizard is prevented if the syntax is
changed. Normally a syntax change is followed by other changes and the logic in
the syntax may not be correct.

Curved Hull:

Incident Issue Description


Number Number
95399 Title: Fatal error occurs while creating a shell plate when bodyplan view is
present in the main view port.
Symptoms: When creating a new Shell Plate and there is a Bodyplan view
present the system fails if the plate is outside the Bodyplan view limits.
Known workaround: Do not create Shell Plates when a Bodyplan view is
present or make sure the Shell Plate is within the Bodyplan view limits.
Solution: Shell Plates will be possible to create outside a Bodyplan view limits.
I-57550, 97172, Title: No holes in 3D displayed by symmetrical cpanel.
I-57545 97151 Symptoms: Holes in symmetrical Curved Panels are not properly displayed in
3D view.
Known workaround: No known workaround exists.
Solution: The holes will be correctly displayed.
I-58846 101619 Title: Disappear Long No in Bodyplan
Symptoms: When using the function "Recreate View" on a Bodyplan view, the
longitudinal numbers disappears from the view.
Known workaround: Remove the view and make a new Bodyplan view.
Solution: The longitudinal names will remain in the view after recreation of the
view.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 490 of 517
Product Release Letter
Hull Structural Design:

Incident Issue Description


Number Number
I-46384 73681 Title: Making text available for RSO's
Symptoms: No text's available in RSO's made as backdrops in Outfitting
Known workaround: No known workaround exists.
Solution: Text is added as geometry and clearly visible in the backdrop.
I-48822 77076 Title: Error calculating paint areas
Symptoms: If a surface that has been used as a boundary reference in a planar
panel is missing, the paint calculation will fail if that panel is used as a restriction
for the room.
Known workaround: Make sure all surfaces are available.
Solution: A more robust handling of missing surfaces has been introduced and
the panel that cause the problem can be easily identified.
I-53632 89912 Title: Enhancement request for statement of doubling plate in schema data.
Symptoms: The doubling plate (DOU) in Hull Modelling will always be numbered
in the sequence they are modelled. For all other components it is possible for the
user to control the sequence number (with help of NO or CNO). To not be able to
control the number makes it difficult to keep persistent numbering.
Known workaround: Make sure the doublings always is modelled in the same
order.
Solution: The keyword NO is introduced for the doubling component to be able
to control the doubling number.
I-56172 94358 Title: WCOG problem for bead (FRP).
Symptoms: Beads get no weight.
Known workaround: No known workaround exists.
Solution: Beads are correctly handled and will get a weight.
I-55165 96859, Title: Swage on panel bounded by RSOs.
92262 Symptoms: When referring a boundary to an RSO, the swage is not correctly
presented.
Known workaround: Use the panels as boundaries.
Solution: The issue is corrected so that RSO's can be used as boundaries also
when swage is defined.
96998 Title: Swage not drawn correctly in 3D canvas.
Symptoms: When adding many swages to a planar panel, the 3D presentation of
the swage panel will fail to be drawn.
Known workaround: No known workaround exists.
Solution: The limit of swages has been removed.
I-57571 97214 Title: Curve hull view properties - duplicate texts
Symptoms: Using Symbolic View > Curved Hull View > Properties and switch on
longitudinal., longitudinal name is output for each individual stiffener. Each text is
put twice, slowing down the system.
Known workaround: No known workaround exists.
Solution: Only one text for each shell stiffener is presented.
I-57573 97224 Title: System down with RSO modification window.
Symptoms: When in the RSO Edit form and clicking in the form e.g. on the
Curve tab, the system will eventually abort.
Known workaround: Minimize the number of non-relevant clicks in this window.
Solution: The error is corrected and irrelevant clicks will be ignored.
97358 Title: Functional Description on component not stored correctly
Symptoms: Using the function 'Functional Description' and adding a description
to a planar profile without doing manual recreation of the panel, will lose the just
added functional description.
Known workaround: Add the Functional Description manually in the schema.
Solution: The functional Description will be handled in a correct way.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 491 of 517
Product Release Letter
Incident Issue Description
Number Number
I-57363 98387 Title: Increasing system number of Pillar has a problem
Symptoms: When user create second pillar statement wizard doesn’t display
next no unlike creating stiffener.
Known workaround: Ignore the number and change in the schema file if wrong
number has been used.
Solution: The correct next number will be shown.
101005 Title: Blocks cannot be Recreated.
Symptoms: If a block contains a surface limit, the system fails to recreate the
block. It is also not possible to extract data from such block.
Known workaround: No known workaround exists.
Solution: The handling of blocks with surface limits has been corrected.

Space Management:

Incident Issue Description


Number Number
I-57910 97511, Title: The stiffeners generated are duplicated when we try to get steel structure
98168 within a space for knuckle RSO.
Symptoms: When more than one cutter is used, it happens that the system
creates more stiffeners than required. This is when the second cutter is used
against the new planar panels.
Known workaround: No known workaround exists.
Solution: Correction made to handle more than one cutter at the same time.
I-57910 98168, Title: Some Panel is overlapped in Temp.block.
97511 Symptoms: When more than one cutter is used, it happens that the system
creates more panels than required. This is when the second cutter is used
against the new planar panels.
Known workaround: No known workaround exists.
Solution: Correction made to handle more than one cutter at the same time.
I-58311, 101309, Title: Space Arrangement World not updated after new SPMSW created
I-54509 90770 Symptoms: Creating a new Space World is not reflected in the drop down list in
the form where to create new spaces.
Known workaround: Exit and restart Space Management and the Space world
will be present in the drop down list.
Solution: The drop down list is updated with the new Space World.
I-59133 102646 Title: Lowercase Letter in naming causes inconsistency in Space Management
Symptoms:
Known workaround: Avoid the use of lowercase letters.
Solution: Both capital and lowercase letters will be handled.

Design Reuse:

Incident Issue Description


Number Number
I-57342 96741 Title: Diagrams renaming do not work
Symptoms: When exporting Diagrams in Design Reuse, the Schematic
Segments, SCSEGMENT, are missing the rename function.
Known workaround: Manually edit the datal file to do renaming.
Solution: The rename function has been added to the SCSEGMENT.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 492 of 517
Product Release Letter
Incident Issue Description
Number Number
97010 Title: Transfer set fails to get exported to location other than the default Temp
directory.
Symptoms: when exporting in Design Reuse, the path name of the receiving
catalogue must not contain any dot "." in the name. The result will be that the
exported file is stored in the default temp directory.
Known workaround: Use a catalogue name where no dots are included.
Solution: The dots will also be handled in the path names.

Hull Production:

Incident Issue Description


Number Number
I-27878 58926 Title: No Functional description code or text in 3-axis nesting gen file.
Symptoms: The FUNCTIONAL_DESCR_CODE and
FUNCTIONAL_DESCR_TEXT are missing from 3-axis nesting gen file.
Known workaround: No known workaround exists.
Solution: The keywords and its values are included.
I-44238 69802 Title: MARK_ABUTTING_PP in Ppanparts.ip does not work.
Symptoms: When a cutout is using a RSO reference instead of a planar panel
reference, the MARK_ABUTTING_PP will not add any marking on the
penetrating stiffener.
Known workaround: Use the planar panel reference instead of the RSO
reference.
Solution: The RSO reference will be correctly handled and the marking will be
added to the penetrating stiffener in the same as if the reference was to the
planar panel.
I-51354 84501 Title: All Character does not appear in GUI.(Curved Hull).
Symptoms: In some selection GUI, the fields are too short so that the full text
cannot be read.
Known workaround: No known workaround exists.
Solution: The fields have been extended so that the full text can be read.
I-51598, 85363, Title: Jig pillars using bounding seams
I-58261 99273 Symptoms: Creating a jig object using bounding seams, in log file the message
“Cannot find surface reference”, may appear and no object is created.
Known workaround: The reason is that the user is not using a proper name of
the jig to be created and the system cannot find a manufacturing package. If a
correct name is used, there are no problems to create such jigpillars.
Solution: A proper message that there is no proper manufacturing package will
be written in the log file.
I-51862, 85638, Title: Problem to use macro clips
I-56272 94631 Symptoms: If a compiled geometry macro is called and the file size of the called
macro is zero, the system will fail.
Known workaround: Make sure all macros are correct compiled and is of no
zero size.
Solution: Proper message will be displayed and the system will continue.
I-53180 87785 Title: Offset table not generating for Cross Bending Template.
Symptoms: Adjustable templates in Cross Bending Templates are missing.
Known workaround: No known workaround exists.
Solution: The adjustable templates in Cross Bending Templates are
implemented.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 493 of 517
Product Release Letter
Incident Issue Description
Number Number
95166 Title: Default values in the Hull Mark dialog should be the same as in previous
versions.
Symptoms: Hull Mark Type has been default set as Plate 12.1.SP4 when
creating a Hullmark.
Known workaround: Manually change to Cont. Weld.
Solution: The default has been changed to Cont. Weld.
I-56998 96113 Title: Cannot create a Hullmark on stb'd side as continuous weld type
Symptoms: Creating a Hullmark on Starboard side as a continues weld type
fails on symmetrical surfaces. If the surface is defined as a whole surface, there
is no problem. Also this is not a problem if the Hullmark is defined as Plate.
Known workaround: No known workaround exists.
Solution: Hullmarks on Starboard side on symmetrical surfaces will also be
handled correctly.
I-56207 96199, Title: Hole for curved panel is created incorrectly in PLDB
95433 Symptoms: Scenario: Curved Panel with symmetry SB, containing Shell Plates
with symmetry 'PS and SB'. Holes placed in this panel will not be at the correct
location.
Known workaround: No known workarounds exist.
Solution: The issue is corrected. The parts needs to be recreated (Curved Part
Generation).
I-57048 96241, Title: Some the sight line of the bending template is created abnormal.
99201 Symptoms: If the LARGESIGHTLINEMARK is defined in bendingtemplate.ip,
some sightlines may be created outside the template as a very long line towards
the centre line.
Known workaround: No known workaround exists.
Solution: Sight lines are corrected.
I-57410 96865 Title: Enhancement request for New PPM (TMPLATE).
Symptoms: Hull PPI will not recognize structures built by TMPLATE's.
Known workaround: No known workarounds exist.
Solution: Hull PPI will also handle TMPLATE.
97031 Title: Unable to create/modify hull marks in the 3 axis
Symptoms: Unable to create or modify hull marks by defining X,Y, Z positions in
3D axis when rotation angle is zero. Only 2D axis is taken as valid.
Known workaround: No known workaround exists.
Solution: The position in 3D and rotation is properly handled.
97034 Title: Modifying Hull marks leads to non-exact valves from previously defined
XYZ values
Symptoms: Modifying a Hullmark that was previously defined where the
"Looking towards" filed was set to ANY direction (defined via X Y Z), this field is
not correctly handled. The values that are presented are not the values given by
the original definition.
Known workaround: No known workaround exists.
Solution: The field will be properly handled presenting the valid data.
I-57503, 97076, Title: Ppanarts error on outfitting steel.
I-57933 98281 Symptoms: If an outfitting steel plate has a hole defined by NXTR, the automatic
production part creation will fail with the message: Couldn't add production
reference!
Known workaround: No known workarounds exist.
Solution: The problem is corrected and NXTR will be correctly handled.
I-57710 97553 Title: A fatal error happened when enter string the asterisk (*) character in new
PPM.
Symptoms: In Hull PPI when selecting Frameworks using option 2. Within
Volume of and give an asterisk (*) as input, the system will abort.
Known workaround: No known workarounds exist.
Solution: The search will also handle the case when asterisk is given.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 494 of 517
Product Release Letter
Incident Issue Description
Number Number
I-57933, 98281, Title: Autopos framework doesn't work.
I-57503 97076 Symptoms: Autopos will not recognize an Outfitting steel model. In the input file,
the graphical selection will be written as the data base reference. This is not
recognized as an object name in the Autopos batch process and the message
that no objects found will be written in the log file.
Known workaround: Manually add the correct name in the input file.
Solution: Correct name will be set in the input file for Autopos when indicating
an Outfitting steel object.
98765 Title: The hole created on the clip is shown outside in the drawings.
Symptoms: Holes added to a clip may very well be added outside the clip
contour. There is no check that the hole is correctly defined inside the clip.
Known workaround: Manually check each clip before sending it to production.
Solution: The system will at creation check that the hole is inside (or at least
intersects) the clip boundaries. If the hole is outside the clip, an error will be set
(6056 No intersection with the hole contour).
I-57048 99201,96 Title: Some the sight line of the bending template is created abnormal.
241 Symptoms: If the LARGESIGHTLINEMARK is defined in bendingtemplate.ip,
some sightlines may be created outside the template as a very long line towards
the centre line.
Known workaround: No known workaround exists.
Solution: Sight lines are corrected.
I-58261, 99273, Title: Seam Base Jig is not working.
I-51598 85363 Symptoms: If a Jig object is defined via seams and there is no proper
manufacturing package, the system simply stops with a message not explaining
at all why.
Known workaround: Make sure a proper manufacturing package exists.
Solution: A proper message will be written in the log file to make it clear to the
user that the manufacturing package is missing.
I-58681 101129, Title: Q SYMMELE does not work
102385 Symptoms: There is an attribute 'SYMMELE' for hpanel and cpanel.
Using the query [Q SYMMELE] does not work, only [Q SYMELE] works.
Known workaround: Use [Q SYMELE]
Solution: The attribute SYMMELE is renamed to SYMELE.
I-58803 101546 Title: Old BentTempl not kept in drawing.
Symptoms: If the bending template application has been run twice with the
options to keep old templates, the old templates are not displayed in the result
drawing.
Known workaround: Use cross bending template instead.
Solution: The issue is corrected and the missing templates will also be included
in the drawing.
I-59167 102683 Title: New IP for hiding the right-angle marks.
Symptoms: The anglemarks on templates are always shown.
Known workaround: No known workaround exists.
Solution: New control setting (HIDEANGLEMARK) has been added for hiding
the angle mark on templates.
I-59168 102684 Title: Changed orientation of the sight-line plane in case of frame templates.
Symptoms: Marked sight line plan on the templates has wrong direction.
Known workaround: No known workaround exists.
Solution: Correction in the application of the sight line plane calculation.
I-59197, 102798, Title: Cpanparts crashes with new CPANEL without bending templates.
I-57599 97255 Symptoms: If no bending templates are defined for the Curved Panel, the
system will fail to split and develop the shell plates that belong to that panel.
Known workaround: Define Bending Templates for the Curved Panel before
using PPI.
Solution: The system will be able to handle Curved Panels where no Bending
Templates are defined.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 495 of 517
Product Release Letter
Hull Weld Planning:

Incident Issue Description


Number Number
I-46095 68454 Title: The weld line between the bracket and knuckled longitudinal is not created.
Symptoms: Weld detection may fail for a bracket attached to the end of a twisted
stiffener.
Known workaround: No known workaround exists.
Solution: The weld detection will handle the case where the shell stiffener is
twisted.
I-48004 74516 Title: Detect welds brings the system down
Symptoms: An assembly where the base plane is defined by a Curved Panel
where no Jig arrangement has been calculated may lead to a fatal abortion of the
system.
Known workaround: Make Jig arrangement for the Curved Panel.
Solution: The behaviour is changed to also handle Curved Panels where no Jig
arrangements have been defined.
I-49277 78073 Title: Cannot create weld line.
Symptoms: Weld detection on stiffener crossing a block boundary fails.
Known workaround: No known workaround exists.
Solution: The detection is corrected to also handle stiffeners crossing a block
boundary.
I-49365, 78248, Title: Weld line on the joint block was created without taking into account the
I-50302 80279 shape snip.
Symptoms: Weld calculation does not consider a sniped endcut properly of a
flange that ends at a planar panel. The weld will in this case get the full flange
with instead of the sniped length.
Known workaround: No known workaround exists.
Solution: The endcut of the flange is correctly handled.
I-50298, 80264, Title: The weld line between the bracket and knuckled longitudinal is not created.
I-46095 68454 Symptoms: Weld detection may fail for a bracket attached to the end of a twisted
stiffener.
Known workaround: No known workaround exists.
Solution: The weld detection will handle the case where the shell stiffener is
twisted.
91595 Title: Welds not detected around flange within a hole.
Symptoms: Flanges in holes when the planar panel contains more than one hole
are not detected by Weld Detection. If only one hole is available in the panel and
it contains a flange, then the flange is detected.
Known workaround: No known workarounds exist.
Solution: The issue is solved so that all the flanges are detectable.
91606 Title: For weld detect on SB side also PS welds are detected.
Symptoms: Panels defined on Port side but only valid on Starboard, the weld
calculation is done on port side.
Known workaround: Define the Starboard panels on starboard side directly.
Solution: The error has been corrected.
91607 Title: Welds not detected on profiles split on plane.
Symptoms: The connection between two planar profiles that has been split by a
plane is not recognized in Weld Detection.
Known workaround: No known workaround exists.
Solution: Weld is now detected also for profiles split with a plane.
91800, Title: Welds not detected between bracket and curve flange.
98364 Symptoms: Weld will not be detected between a bracket and a curved flange.
Known workaround: No known workaround exists.
Solution: The issue is corrected.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 496 of 517
Product Release Letter
Incident Issue Description
Number Number
I-56871 95784 Title: Unnecessary welds are created for unconnected parts.
Symptoms: Planar panel limits defined with an offset (CORR) will always be
recognized by the weld detection.
Known workaround: No known workaround exists.
Solution: A default distance of 20 mm is introduced. If a limit has a parallel
displacement more than 20 mm it will not be recognized by the weld detection.
I-56874 95789 Title: Weld line created without regard to plate thickness.
Symptoms: The weld on one of the mould side of a profile web is calculated
correctly but the weld on the material side is calculated in the wrong direction
placing the weld inside the profile.
Known workaround: No known workaround exists.
Solution: The thickness will be taken into consideration.
I-56876 95798 Title: Weld line created on opposite side.
Symptoms: Clips (collar plates) in a symmetrical panel in a cutout for a starboard
specific shell profile will create the weld at port side.
Known workaround: No known workaround exists.
Solution: The weld will be created at the correct location.
I-57504 97081 Title: The butt weld lines for jointed plates were not displayed in 3D view.
Symptoms: Weld lines seem to be missing in 3D view if the weld height is small.
Known workaround: No known workaround exists.
Solution: All weld lines will be displayed.
I-57575 97225 Title: Created weld line for doubling is not correct.
Symptoms: Weld between planar panel and doubling plate on starboard image
of a symmetrical panel is calculated on the wrong side of the planar panel.
Known workaround: No known workaround exists
Solution: Weld calculation is done on the correct side of the panel.
97575 Title: Welds not detected on Rudder.
Symptoms: Missing welds against the shell. If the planar panel boundary is
defined as a curve, the weld detection fails.
Known workaround: Instead of using a named curve in the planar panel
boundary, the shell can be referred to directly. Weld detection will then find this
connection.
Solution: The boundaries described with a curve will be recognized by the weld
detection.
98135 Title: Extra Weld detected.
Symptoms: For abutting profiles, the ends are not properly detected by Weld
Detection. It could also detect the part of the profile end that should not have any
weld, e.g. the notch in the endcut.
Known workaround: No known workaround exists.
Solution: The Weld Detection will find only the part of the profile end that should
have weld.
98364, Title: Welds between bracket and flange not detected.
91800 Symptoms: Brackets attached to a curved welded flange will not be recognized
by Weld Detection.
Known workaround: No known workaround exists.
Solution: The brackets attached to a welded curved flange will be recognized by
weld detection.
98400 Title: Provision of butt welds between the curved panels and planar panels.
Symptoms: Butt weld between Planar plate and Curved plate is not detected.
Known workaround: No known workaround exists
Solution: Butt welding between Planar plate and Curved plated has been
implemented.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 497 of 517
Product Release Letter
Incident Issue Description
Number Number
I-58530 100491 Title: Add welds to drawing (MarAPI).
Symptoms: In MarAPI MarDrafting.ModelDraw function MarModel, there is no
model type "Weld table", "WeldedJoint" or "Weld".
Known workaround: No known workaround exists.
Solution: MarAPI has been extended with partidpml.
To draw whole weld table:
-----------------------------
...
!Model = object MarModel()
!Model.Name('WT=24104/126')
!Model.type('weld table')
!Drafting.ModelDraw(!Model)
To draw a specific joint within the table:
------------------------------------------
...
!Model.Name('WT=24104/126')
!Model.type('weld table')
!Drafting.ModelDraw(!Model)
!Model.parttype('welded joint')
!Model.partidpml(4) --> the value if the "tbid" attribute of the MWLDJT element.
!Drafting.ModelDraw(!Model)
I-58531 100492 Title: SP4 - draw single weld or joint on a drawing.
Symptoms: It is now possible to draw welds on a drawing. However - drag&drop
a weld or joint from Design Explorer to a view - the whole weld table is displayed
(all welds).
Known workaround: No known workaround exists.
Solution: Single joints are possible to draw.
I-58855 101658 Title: Wrong part names in weld report.
Symptoms: Part names for SB parts will be wrong in the weld report.
Known workaround: No known workaround exists.
Solution: Correct names will be printed in the weld report also for SB parts.

Hull Nesting:

Incident Issue Description


Number Number
I-39616, 67178, Title: Problem when inserting sub-pic to Nesting sketch
I-43348 67179 Symptoms: When in the Nesting Sketch mode, adding geometry and sub-
pictures, those are not handled properly in the sketch. When toggling between
the Nested Plate and the Nesting Sketch, the sub-picture is not correctly shown in
the sketch.
Known workaround: Nesting sketch can be opened with File - Open drawing,
and then place the sub-picture
Solution: The sub-picture handling in Nesting Sketch has been approved and will
be added in a new layer. This will prevent the sub-picture to be wrongly
displayed.
I-50968 85405 Title: Labeltexts for markings on the other side of the part are not set by
LabelText->PosNo->Automatic.
Symptoms: When making Label text automatically in Nesting, the marking
position numbers on the "other" side of the plate is not distinguished from the
once located on "this" side.
Known workaround: No known workaround exists.
Solution: A new default keyword, LABEL_PREFIX_OS, has been introduced. By
setting this to e.g. OS, the marking position numbers that are located on the
"other" side will get this prefix so they are easy to locate.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 498 of 517
Product Release Letter
Incident Issue Description
Number Number
I-57376 94756, Title: The Excess and the sketch info overlap each other in the nesting Sketch.
96777 Symptoms: If adding excess to plates, the excess and plate information texts will
overlap. Also Burning sequence number is coming out of the symbol.
Known workaround: Move the texts manually after they have been added.
Solution: The text overlap in the sketch has been improved. For the side
information, two new defaults has been introduced, AUTO_SIDE_INFO_DX and
AUTO_SIDE_INFO_DY to move the side information that sometimes clash with
the excess text.
95364 Title: Nesting defaults is not working properly.
Symptoms: In the Nesting Sketch, the position number symbols fir stiffener
markings does not fetch the symbol number from the default keyword
POSNO_SYMB_MARK.
Known workaround: Modify symbols manually in the sketch.
Solution: The correct symbols will be used when the drawing form is inserted.
95402 Title: Unable to move Symbol in the Sketch.
Symptoms: In the burning sketch when trying to move a position numbering
symbol with the function Plate Nesting-->Shop Drawing Information-->Symbol--
>Move, the system will not recognize the symbol.
Known workaround: Use Right Click function "Move position number" to move
the position number.
Solution: The issue is corrected.
95863 Title: In the last form page exist some data from the previous page.
Symptoms: When automatically filling in Nesting Sketch tables and more pages
are required to fill in data, the last table is filled in with too much data. The first
part of the table from page one is filled into the last page.
Known workaround: No known workaround exists
Solution: The last table will not be filled in with the extra data.
I-56945 95973 Title: In burning sketch, '%' in BASIC_TEXT is not replaced by the symbol for
degrees.
Symptoms: If a Unicode text font is used, the degree symbol in bevel notes in
nesting will fail to present the correct symbol.
Known workaround: Use a non-unicode symbol font for bevel notes in Nesting.
Solution: Unicode fonts is supported in bevel notes in Nesting sketches.
96463 Title: Default 'AUTONEST_FORMNAME' takes numeric value when the form is
changed.
Symptoms: When changing the form in the default by interactively selecting the
form from the selection list, the form name shown is the data base reference
number and not the form name.
Known workaround: Manually key in the form name.
Solution: The indicated form name will be inserted as the new default form.
96789 Title: Right click for context menu Labelling texts and symbols are not available.
Symptoms: When Right Click on a labelling text, the label text is not recognized.
Known workaround: The function is available in the Nesting Menu.
Solution: Move label text and label symbol is recognized by the Right Click
function.
96791 Title: After defining Bevel Impossible to recreate message is show in Message
window.
Symptoms: When defining bevels in a plate part and when ready, the message
"Bevel Impossible to recreate" is shown to the user. This happens if direction
marks has been added before the bevels are defined.
Known workaround: Do not add direction marks before defining bevels.
Solution: Error is corrected and direction marks may be present when bevels are
defined.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 499 of 517
Product Release Letter
Incident Issue Description
Number Number
96847 Title: Opening a 3 Axis Nesting leads to error 1002.
Symptoms: Opening a 3 Axis Nesting previously run in Batch will give the error
message 1002 that must be confirmed by the user. The nesting and the nesting
sketch are correct.
Known workaround: No known workaround exists.
Solution: The error behind the 1002 message has been corrected. The nesting is
not affected by either the described error or the fix.
I-57494 97063 Title: Default keyword DISPLAY_EXCESS_SYMBOL didn't work.
Symptoms: The default setting DISPLAY_EXCESS_SYMBOL has no effect for
automatic placed excess information (AUTO_EXCESS_INFO). The excess
symbols are always displayed also when DISPLAY_EXCESS_SYMBOL is set to
NO.
Known workaround: Remove unwanted excess symbols manually.
Solution: The symbols will not be displayed if DISPLAY_EXCESS_SYMBOL is
set to NO.
97075 Title: The Position number of plates is not getting displayed.
Symptoms: After verification of a Nesting, the function "LabellingSymbol ->
Position Number" will not show the position number of the part.
Known workaround: No known workaround exists.
Solution: The error is corrected. New verification must be performed.
97344 Title: Invalid Bridge and start point created in nesting automatic start.
Symptoms: In a nesting (the nesting view), if a dimension is added and then
automatic starts are added, the system will fail to verify the path.
Known workaround: Remove all starts and the dimension and redo the
automatic start sequence.
Solution: Dimensions will be handled properly also when automatic starts are
added.
I-57639, 97388, Title: Problem when inserting sub-pic to Nesting sketch
I-39616 67178 Symptoms: When in the Nesting Sketch mode, adding geometry and sub-
pictures, those are not handled properly in the sketch. When toggling between
the Nested Plate and the Nesting Sketch, the sub-picture is not correctly shown in
the sketch.
Known workaround: Nesting sketch can be opened with File - Open drawing,
and then place the sub-picture
Solution: The sub-picture handling in Nesting Sketch has been approved and will
be added in a new layer. This will prevent the sub-picture to be wrongly
displayed.
97958 Title: The nesting default 'TEXT_HEIGHT' changes to zero after inserting
drawing form.
Symptoms: The default value of TEXT_HEIGHT in the Nesting default is reset to
zero (0) when a nesting form is included.
Known workaround: No known workaround exists.
Solution: The value will not be affected by inserting a nesting form.
I-58128 98791 Title: Multiple users can open the same nested plate data.
Symptoms: When more than one user opens a Nesting that is already opened
by another user, no message is given that it is locked by another user.
Known workaround: No known workaround exists.
Solution: A message will be given when a locked nest is opened. The Save and
Rename functions will not be available.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 500 of 517
Product Release Letter
Incident Issue Description
Number Number
I-58359 99612 Title: Thickness of parent plate part difference
.Symptoms: When creating a parts menu in Nesting where the default
THICK_CHECK is set to 2 (if thickness is different, operator will be asked for
action), the THICK_CHECK has no affect if the search criteria is via Plate Part
Name.
Known workaround: Create parts menu in other ways e.g. using blocks as
search criteria.
Solution: Also Plate Part Name criteria will be checked if THICK_CHECK is set
to 2.
I-58595 100912 Title: Different thickness search on parts menu.
Symptoms: If a new nesting is created, for example with 7 mm, the system
search only 7 mm parts and bring to parts menu. ıf also 8 mm parts are required
in the parts menu, it is not possible.
Known workaround: Manually search for parts to be included in the nesting.
Solution:
The Nesting default parameters THICK_DIFF_MIN and THICK_DIFF_MAX can
be used to select parts in a thickness interval. If THICK_DIFF_MIN = 0.0 and
THICK_DIFF_MAX = 1.0, all parts with thicknesses between e.g. 7 and 8 mm will
be selected.
In the parts menu it is now possible to add selections from different thicknesses.
The check box for "Keep existing parts in the menu" must be checked. In that
case, only parts with the given thickness are extracted.
I-58612 100913 Title: Position numbers are going to left bottom corner of nesting sketch.
Symptoms: When inserting the drawing form, all position numbers are going to
left bottom corner of nesting sketch if no position number symbols are defined.
Known workaround: No known workaround exists.
Solution: The position numbers are correctly placed in the nesting sketch.
101267 Title: While creating profile using profilepart programming form we are not able to
give zero value or empty string in the fields.
Symptoms: In the Profile form it is not possible to leave the Bevel field empty.
Also it is not possible to give negative excess.
Known workaround: Make the profiles with help of the modelling tools in Hull
Design.
Solution: The form is corrected to accept empty fields and also to accept
negative values.
101269 Title: Fatal error message appears on inserting drawing form.
Symptoms: System aborts when Nesting Drawing Form is inserted. This
happens if Marking Line Groups for Part Checking is defined.
Known workaround: Remove the Marking Line Group from the Part Checking
setup.
Solution: Correction is done so that Marking Line Groups can be defined in the
project.
I-59045 102458 Title: SBH_BURNER_DATA prevents Hull Design from starting in 12.1SP4
Symptoms: The system aborts during start-up with the message "%BURNER-E-
WARNINGS, Interpretation completed with warnings" in the console window.
Known workaround: De-assign the SBH_BURNER_DATA file.
Solution: The burner file is correctly interpreted.
I-59225 102842 Title: Wrong knuckle angle note and pos no on knuckle panel parts in nesting
sketch.
Symptoms: The angle of a knuckle line in a knuckled plate is incorrect and also
a position number is presented for the knuckled line.
Known workaround: No known workaround exists.
Solution: Correct knuckled angle will be presented and no position number will
be presented for the knuckled line.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 501 of 517
Product Release Letter
Incident Issue Description
Number Number
I-59264 102927 Title: Data error while exchange rawplate.
Symptoms: In Nesting, after exchange the rawplate and save the nesting job,
each time the system will create a new RAWPLA element.
I.e. if raw plate is exchanged 10 times, system will create 10 RAWPLA elements.
Known workaround: No known workaround exists.
Solution: System will not create new RAWPLA elements in this situation.

Marine Drafting:

Incident Issue Description


Number Number
I-30782 60552 Title: Missing functionality with lowercase named drawings
Symptoms: A drawing which name consists of lower case letters is not
recognized by other Marine Drafting functions.
Known workaround: Use only uppercase letters.
Solution: Lower case letters in the drawing name will also be handled.
I-42704 66618 Title: dwg elements are not imported.
Symptoms: The spline elements in a drawing exported from Autocad in dwg
format is not correctly imported into Marine drafting.
Known workaround: Export drawings in Autocad in DXF R12 version.
Solution: The spline elements have been updated to be handled correctly also
when importing DWG format.
I-43278 67003 Title: Text Height defaults not used immediately
Symptoms: When setting TEXT_STD_HEIGHT, from the default form within
HullDesign, the change is not seen when adding a new dimension within
modelling.
Known workaround: Change the default, save the default fine and then restart
the system.
Solution: A new Drafting default keyword TEXT_HEIGHT has been introduced
for the modal text height. The system default value is the value of the keyword
TEXT_STD_HEIGHT. (I.e. when loading a default file, and the keyword
TEXT_HEIGHT is missing then the value of the TEXT_STD_HEIGHT is used
for modal text height).
I-37398 69346 Title: Panel Intersect Function - Symbol placement error
Symptoms: The function Tools > Model > Panel Intersect erroneously places
arrows for intercostal panels at the mould side of the other panel.
Known workaround: Use the function and then manually move the symbol to
the correct place.
Solution: The symbol is placed correctly.
I-1532 80878, Title: Weld line on the joint block was created without taking into account the
40794 shape snip.
Symptoms: Weld calculation does not consider a sniped endcut properly of a
flange that ends at a planar panel. The weld will in this case get the full flange
with instead of the sniped length.
Known workaround: No known workaround exists.
Solution: The endcut of the flange is correctly handled.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 502 of 517
Product Release Letter
Incident Issue Description
Number Number
I-51729, 86167, Title: SaveWork interferes wrongly with Drawing > Save
I-19965, 92890, Symptoms: When opening a drawing and deleting some primary elements
I-42232 56265, (e.g. an Id list or slice view), doing a SaveWork and then closing the drawing
67496 (not storing the drawing), the system fails to keep the drawing in sync and the
next time the drawing is opened it is not correctly synchronized with the PADD
data base.
Known workaround: No known workaround exists.
Solution: The issue is fixed so if the primary elements are correctly handled
when a drawing is closed (or saved).
I-53073, 87614, Title: Using context menu to place HULL notes.
I-56946 Symptoms: The Geometry Toolbar is inactive, when you are using some
Annotate functions.
Known workaround: No known workaround exists.
Solution: The possibility to select the way of defining points (via right mouse
button or Geometry Point toolbar) for the leader line has been implemented in
the following functions:
- Annotate/General Note
- Annotate/Position Number
- Annotate/Hull Note
- Annotate/Config Note
I-52921 87767, Title: A fatal error occurred leading to crash when exporting a DXF file with
87398 outfitting and Hull elements.
Symptoms: A fatal error when exporting outfitting elements to a DXF file that
will result in a general cylinder.
Known workaround: No known workaround exists.
Solution: The issue is handled and the DXF export will complete.
I-54294 90448, Vitesse -
97478 Title: kcs_ui.string_select error.
Symptoms: When adding alternatives to the Vitesse UI function "string_select",
the system aborts if more than 8 alternatives are added.
Known workaround: Add no more than 8 alternatives.
Solution: The number of alternatives has been extended to 100. All over 100
will be ignored.
I-54677, 91354, Title: Adding new items to an existing view (hidden line type) has to be
I-58057 98827 followed always by Update Design
Symptoms: When adding items to a new view, is mandatory to use Update
Design.
Known workaround: No known workaround exists.
Solution: The issue is handled so that Update Design is not necessary after
adding new items to a hidden line type view.
I-54916 91921 Title: Adding labels by AutoTagging for a previously 2D restricted view.
Symptoms: When removing a 2D restriction, the label function (including Auto
tagging) is failing to identify any model that was outside the 2D restriction zone.
Known workaround: It is possible to manually change the size of the view
from the Command Window by setting the size of the view equal to the size of
the sheet element.
Solution: The views will be correctly updated when a 2D restriction is removed.
I-54919, 92175, Title: User cannot import big size drawing at the marinedraft.
I-57105, 96335, Symptoms: Very large DXF files will make the system to unexpectedly exit.
I-57101 96332 Known workaround: No known workaround exists.
Solution: The problem with very large DXF files has been resolved and the
system will import the whole drawing.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 503 of 517
Product Release Letter
Incident Issue Description
Number Number
I-56702 95459 Title: Split/Regroup by Polygon/Area should take into account model items
within subviews.
Symptoms: When the functions "Subpicture Regroup" or "Subpicture Split", the
only way to make sure all subpictures are included in the selection is by picking
them manually one by one.
Known workaround: Pick subviews one by one.
Solution: When regrouping subpictures (views/subviews/components) by
picking subordinates/neighbours, all subpictures inside a user-defined polygon
can be captured by pressing Options buttons when the user is asked to indicate
the subordinate/neighbour.
I-56985 96224 Title: The selection model problem using 'Identify model' function on Label
Placement.
Symptoms: When using the function "Label Placement" and identifying
equipment, all labels are highlighted.
Known workaround: No known workaround exists.
Solution: The issue is corrected so that only the indicated label is highlighted.
I-57101, 96332, Title: Cannot Import DWG to Marine Drafting
I-57105, 96335, Symptoms: Very large DWG files will make the system to unexpectedly exit.
I-54919 92175 Known workaround: No known workaround exists.
Solution: The problem with very large DWG files has been resolved and the
system will import the whole drawing.
I-57018 96396 Title: DwgNew() not working with new Forms.
Symptoms: Using the MarAPI function 'dwgNew' and using a drawingform with
predefined views and has been updated in 12.1.SP4, will abort the system.
Known workaround: No known workaround exists.
Solution: The function is corrected to also be able to handle updated
drawingforms.
I-56946 96495 Title: Using context menu to place HULL notes
Symptoms: The Geometry Toolbar is inactive, when you are using
some Annotate functions.
Known workaround: No known workaround exists.
Solution:
The possibility to select the way of defining points (via right mouse button or
Geometry Point toolbar) for the leader line has been implemented in the
following functions:
- Annotate/General Note
- Annotate/Position Number
- Annotate/Hull Note
- Annotate/Config Note
I-57230 96571 Title: The label placement is not working when you select "remote" with
"region.
Symptoms: The label placement is not working when you select "remote" with
"region" and a value becomes negative.
Known workaround: The form is a graphical interface to the pml SPREAD
command. It is possible to call this manually in the command line window with
any parameters.
Solution: The form is corrected to handle also negative values.
I-57191, 96607, Title: A fatal error occurred leading to crash when exporting a DXF file with
I-55968 93951, outfitting and Hull elements.
87767 Symptoms: A fatal error when exporting outfitting elements to a DXF file that
will result in a general cylinder.
Known workaround: No known workaround exists.
Solution: The issue is handled and the DXF export will complete.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 504 of 517
Product Release Letter
Incident Issue Description
Number Number
I-57419 96974 Title: If have $2000 in format, format name appear below that $2000.
Symptoms: When opening a drawing form (Tools/Drawing Form/Open), the
name of the drawing (converted from the drawing form definition) has by
mistake been added to the drawing (at the position of the $2000 rule text).
Known workaround: No known workaround exists.
Solution: The form name will not be added to the rule.
I-57495, 97065, Title: Fatal error encountered taking 3D Dimension.
I-54737 91764 Symptoms: The 3D coordinate dimension will give a fatal error if indicating in a
Shell Expansion View.
Known workaround: Do not indicate in a Shell expansion View.
Solution: The issue is corrected and 3D coordinates is possible to get also
from the Shell Expansion View.
I-58048 98561 Title: There is a problem in search drawing with the progress bar.
Symptoms: In the Open Drawing dialogue, if by accident double click on the
List button, two or more progress bars will appear and stay until the application
is closed.
Known workaround: No known workaround exists.
Solution: There will be only one progress bar and it will close properly when
the search is ready.
I-58246 99205 Title: When open the Drawing Default Name column field should extend more
60 character length.
Symptoms: In the dialogue "Open Drawing" the column for drawingnames only
show the first 28 characters in the name.
Known workaround: Manually extend the column width to be able to see the
full name.
Solution: The Name column has been extended.
I-58247 99206 Title: Symbol was disappeared. When using with General Note.
Symptoms: When adding geometry (or symbol) to a note component it
disappears when the note component is modified.
Known workaround: No known workaround exists.
Solution:
Additional information added to the note component will be handled when
moving the note (via Modify/Move/Reference).
I-58922 101956 Title: MarineDrafting: System crashes with floated ViewPort.
Symptoms: The system will abort when a floating viewport is closed.
Known workaround: Do not close the floating viewport.
Solution: The close of a floating viewport is correctly handled by the system.
102542 Title: Drag and drop operation of Design World to Main viewport leads to
Crash.
Symptoms: By dragging the World into the Marine Drafting Viewport, the
system will abort.
Known workaround: Drag each site/block by itself.
Solution: World will be possible to drag into the Marine Drafting Viewport.
I-59224 102827 Title: Symbolic View - restrict by contour not working anymore.
Symptoms: Make a symbolic view and then restrict it by an arbitrary contour.
When making re-create on this view, the whole view without any restrictions will
be presented.
Known workaround: No known workaround exists.
Solution: The restriction contour will be taken into consideration when
recreating the symbolic view.
103583 See Enhancements.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 505 of 517
Product Release Letter
Diagrams:

Incident Issue Description


Number Number
55489 Files get deleted on using Backtrack Changes function on Schematic data.
87025 An Unwanted message appears when user attempts to export the already
exported item list with the different name.
I-53311 87965 Issues on visiofile with Extract database.
I-54671 91344 Property Break symbols.
I-53091 93255, Excel import: Attributes name and description fails to display in the Excel
87659 Interface Wizard- Import window while importing the exported item list.
93791 Excel Export: An Unhandled exception error occurs when user tries to Move
selected row above/below the grid in the ‘Excel Export ‘window.
95110 Title: Delay when clicking Compare / Update / Link button.
Symptoms: When clicking Compare / Update / Link button Diagrams, the
dropdown in the Manage tab freezes for some time, sometimes for several
seconds.
Known workaround: No known workaround exists.
Solution: Performance has been improved.
I-57335 96734 Spec search.
99303 Ribbon: Command Window button should be moved from the Admin Tab to the
View Tab.
104023 Move PBS Explorer Options from Project tab to Options backstage page.
104028 "AutonameCEAndOffSpring" issue in Diagram module.

Schematic 3D Integrator:

Incident Issue Description


Number Number
66283 Zoom to selection not responding correctly for branches.
78974 An Error message is displayed while trying to access the right click context menu
option in the Diagram Viewer window.
I-57569 97213, Scrollbar is missing in "Run Report" form.
85972
98276 Spurious connection node message for tee with boss connection.
98277 Cyan (means not compared) elbow displayed on comparing line with boss
connection.

Engineering:

Incident Issue Description


Number Number
64449, Tags - Attributes fail to display when a grid has more than one group with
95894 assigned attribute.
65597 Tags - Excel Import: Import window is always on top and may obscure other
windows.
I-45141 67833 Tags - Compare/Update: option to define AcceptAll true/false by default.
72836 Tags - When unpin column, grid is scrolled to the first row.
75717 Tags - Customize window: An Unhandled exception occurs while clicking the
'Apply' button.
I-49028, 77504, DataSheets - Datasheets Instance does not get updated if the Datasheet
I-50446 80844 Template is modified
86352 Tags - Rename window title from Reference Picker to Reference Array browser.
89029 Datasheets - Locked attribute value seems to be updated in datasheet.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 506 of 517
Product Release Letter
Incident Issue Description
Number Number
I-54049, 89989, Datasheets - Creating datasheet template from Excel file containing image.
I-49024 93151,
77501,
85991
I-54052 90026, Datasheets - Delete key functionality.
90129 Datasheets - Add a "Remove Trailing Zeroes" option for Precision in Datasheets.
92186 Tags - All mapped attributes are getting removed when user tries to delete single
row.
92283 Datasheets - Free Text Cell contents is not getting saved for second sheet in
instance if content is imported from Excel.
I-55233 92498 Tags - The list in Tags is based on a DBVIEW (on the UDNAME of the DBVIEW).
If this is changed the list is not working anymore.
92518, Tags - New DateTime does not display or allow the entry of time values.
92523
I-55429 92921 Compare/Update - An unnamed Engite will occur two entries in the CuP grid.
I-55990 92924 Compare/Update - Advanced config should be inside config wizard so under
admin control.
93508 Tags - Grid layout in Tags is lost when modifying or removing columns when
changing database view in Lexicon.
93949 Datasheets - ## is displayed in import grid instead of text value.
94242 Tags - The AVEVA NET Gateway Setup icon is broken in SP4.
I-56292 94654 Datasheets - Boiler plate in Auto mapping form needs to be renamed.
I-56293 94667 Datasheets - "Create and Map" Form should have Accept all button.
I-56298 94672 Datasheets - DataSource pull-down list in Create and Map” Form should
"SRCELE".
95061 Tags - Colour feedback on error and missing data in the grid functionality.
95109 Tags - When clicked, the Tags grid icon for Diagram does not highlight the item.
I-56595 95246 Tags - Greyed the Rename Button if the Name is read-only in the list.
95278 Tags - User fails to Replace LowerCase letter if UpperCase letter has already
been used in the Find and Replace window.
95374 Datasheets - "Index Was Out of Range" is displayed in the message log when
user attempts to import the Datasheet which contains Continuous Area with Free
txt cell.
95394 Datasheets - UOM Standard Control allows user to define a duplicate name.
95435 Tags - Unhandled Exception is displayed on clicking the Clear button in the
Reference Browser window.
95436 Tags - Title: Unhandled Exception is displayed on clicking the 'Documents' folder
in 'Select Transfer Set' window.
Symptoms: When in Tags, using Design Reuse importing data, when indicating
the 'Document' folder, the application will abort.
Known workaround: No known workaround exists.
Solution: The issue is fixed so it is possible to click on the 'Document' folder.
95507 Tags - Short cut key Symbols fails to display for the other modules which is
present under Project tab in Tags Module.
I-56673 95571 Tags - Compare/Update: Problem with filters when doing compare and update
when running multiple projects.
95622 Datasheets - UOM Standard control "feedback colour" remains 'grey in colour’
though cell is unlocked.
95628 Datasheets - Font size changes to default after resizing the merged cell.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 507 of 517
Product Release Letter
Incident Issue Description
Number Number
95644 Datasheets - Remove clear button from reference browser window.
95871 Tags - The Show Whole Box command in the 3D viewer does not work as
expected.
95894, Tags - Tags List Manager: Creating group heading does not work first time.
64449
95953 Datasheets - A Warning message "Wrong element to select" is displayed when
user clicks on 'Owner browse' button in' Datasheet Configuration' window.
95966 Datasheets - Precision value is displayed only in the first element of the
continuation area.
95970 Datasheets - Control moves to last work sheet in Instance when user modifies the
attribute in continuation area.
96157 Tags - Column search highlighting gets unintentionally stored with list definition.
96303 Datasheets - One additional row and column outside continuation area is
considered as part of continuation area.
96312 Tags - Icons in "Diagram icon" column are not displayed after List Manager
changes.
96393 Tags - Excel Export Wizard - Delete button on Worksheet and Element Type
Configuration screen doesn't work as expected.
I-57145 96417 Tags - Datasheets option in “Publish to AVEVA Net” config form is not visible in
old project.
96538 Datasheets - Attribute Name column in "Create and Map” Form should have pull-
down list of attributes name suffix with its corresponding datasource.
96625 Datasheets - Keyboard control for Cut/Copy/Paste fails to function on datasheet
template.
96631 Tags - Messages from datasheet are displayed as warning in Message Log
window of Tags.
96632 Tags - Not able to insert “Material” value in the Tags list information grid.
96698, Datasheets - Error message is not displayed in Tags when user modifies the
96525 Instance which is mapped by 2 DBViews.
96774 Datasheets - 'Auto Hide' function fails to unhide the Datasheet template docked
window when window is hidden.
I-57498 97066 Datasheets - Unable to update datasheets if updating datasheet values from
excel sheet contains comma.
I-57608 97278 Tags - Checking the checkbox in “Select Summaries” Form display Unhandled
Exception.
97281 Tags - PBS is updated for every status change, affecting performance of bulk
operations.
I-57614 97285 Tags - Excel import: No slash is added to NAME and OWNER on excel import.
I-57616 97319 Tags - Unable to update Reference attributes” via Excel Import.
I-57702 97542 Tags - Unable to create top-level element [ENGWLD] from "Create Database"
form.
I-57745 97628 Datasheets - Copying Unit of Measure Cell containing text value crashes Lexicon.
97631 Datasheets - In the 'New Datasheet Instance' dialog, the Tag field shows the Tag
prefixed with a / character. This should not be seen.
97708 Tags - Splitter on grid isn't removed if pinned column gets hidden in List
manager's Field tab.
97776 Datasheets - Real attribute values (UValid values) fails to display in the mapped
cell when user tries binds the “Radio button” standard control.
97783 Tags - Unhandled Exception while clicking Current Session button.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 508 of 517
Product Release Letter
Incident Issue Description
Number Number
97794 Datasheets - The mapped cell colour remains even when the cell containing
Revision Block is deleted.
97807 Tags - After switch from vertical view to regular view hidden groups are
displayed.
97849 Tags - Current Datasheet” option under “Excel Export” menu [Under ‘Manage’
tab] is found to be disabled until random clicks performed.
97879 Tags - Sublist change in ListManager not accepted.
I-57932 98280 Tags - C/U Errors with 'Advanced Configuration' and compare 'By destination'.
98462 Datasheets - Revision mark should be updated when datasheet is refreshed.
98811 PBS - Grouping only works for last node.
99336 Datasheets - Add Revision Marks in datasheets.
100447, Datasheets - Datasheet’s Show leading slash command
97631 (“AVEVA.Datasheets.ShowLeadingSlash”) is not executed if datasheet window is
not open.
I-58619 100914 Tags - Add an option for PBS to activate/deactivate the auto refresh.
101657 Compare/Update - Exception thrown from macro.
103470 Datasheets - Change highlighting in a session.
I-58140 103806, Datasheets - Performance issue in automapping.
98854
104790 Tags - PBS Explore Option” should be moved to Project “Option” Menu in both
Tags and Diagrams.
104957 Tags - Tags application hangs and is not responding.
105024 Datasheets - 'Owner' (UGROUP ) value fails to set in the 'Datasheet setting'
window.

Pipe Fabrication:

Please note that furthermore to the noted fixes below there has also been extensive enhancement work on
the Pipe Fabrication application.

Incident Issue Description


Number Number
94927 Title: Improper Prompt message is displayed on clicking the ‘Remove to spool
drawing by pick' in Multiple Spool window.
Solution: Message and tool tip changed.
I-56820 95721, Title: Unused attributes PPCutLength and a PPFinLength.
99428 Solution: Attributes are hidden now. May be needed for old functionalities.
I-57002 96116 Title: Bending Machine NC Data Form Name update required.
Solution: Form was updated.
96530 Title: Value of OD and WThickness are always displayed in mm unit format in the
Fabrication Machine Manager window and the value entered is taken in CM unit
format and displayed in mm unit format.
Solution: There was an unit converting error when entering new value – fixed.
96888 Open button is displayed instead of Save button in the ‘Save to Excel’ window of
Weld Handling form. Was fixed.
96897 An error message is displayed when user tries to save Galvanization Tank Check
results to Excel sheet. Was fixed.
97271 The Distance unit gets set to the default unit when the clashes window is opened.
Problem fixed.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 509 of 517
Product Release Letter
Incident Issue Description
Number Number
97390 Delete Spool Information option is enabled in the context menu even when the
pipe is not validated in the Fabrication Check form. – Fixed.
I-56734 97501, Title: Outfitting reference error message is displayed while working with Design
95527 Module of PDMS Application.
Solution: In case of spool drawing the application now works as in SP3.
97550 Tick mark is displayed in front of Fabrication Explorer option even when the
Fabrication Explorer form is closed.- Fixed.
I-57767 97671 Title: Additional Button/Option Required on Forms: Add CE button; Remove
Selected option.
Solution: Buttons and functionality was added to the right forms.
97743 Title: Error message is displayed when user enters values for Collision planes in
Fabrication Machine Manager Window while working with imperial units. .- Fixed.
97763 Title: Invalid error message is displayed when user tries to create weld for pipe
claimed by another user. .- Fixed.
97913 Title: Wrong Value is displayed in the Material list table of Pipe spool drawing
while working with Imperial unit settings. – Fixed during internal tests.
97973 Title: Invalid error message is displayed when user selects Insertion Direction in
Machine Insertion Directions window after selecting an Invalid spool. – Fixed
during internal tests.
98099 Title: All files are not exported when PSPOOLS have same name with different
cases. – Fixed during internal tests.
99294 PCRFA attribute of a PPIECE is always unset. Fixed.
I-55633 101721 Problem: Pipe Spool Drawing. Values in column "Units" must be customizable.
In column units should be values in local language. For example:
"EA" (piece/unit) - must be "шт."
"mm" - must be "мм"
Solution: Possibility to assign values of "units" in local language has been
added.
I-54146 101924 Warning for unconnected TEE does not give element name. After running the
"Fabrication Consistency Check" on a pipe that contained a tee which was not
connected, I am getting a warning message that "TEE =16987/1310 is not
connected". This warning message should be giving the element name rather
than the db RefNo.
Problem fixed.
I-56480 102435 The dimension and the ATTA element on the view. The dimension not correctly
created on of the spool. ATTA element has a position in the drawing but not
entered in the specification. ATTA element does not have a position in the
drawing,
Problem was fixed.
I-59059 102529 Incorrect error message when "feed excess" is required.
I-59162 102678 Pipe fabrication spool drawings.
102921 Error message is displayed when user tries to open Weld Gap configuration form.

Multi-Discipline Supports (MDS):

Incident Issue Description


Number Number
104110 An error message is displayed while invoking the paragon module when current
MDB does not contains MDS/MDSAPPDEFAULTS database.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 510 of 517
Product Release Letter
Outfitting:

Incident Issue Description


Number Number
43348 Database and Data Management – ‘Copy Like’ and DAC control.
Solution: An appropriate warning is given if attributes cannot be set.
I-30747 60117 Customisation and Common Framework - Search - Ability to save searches
between users.
Solution: Added new save location based on Project DFLT environment variable.
I-28859, 65162, Draft - Cursor disappearing in Draft.
I-44961 65163
I-31217 64532 Draft - Crosshair graphics missing.
I-42171, 66680, Draft - Unable to see cursor when defining symbol marker point.
I-39226 66679 Solution: The cross-hair cursor is now visible when positioning items.
I-41711 66874 HVAC - Recognizing size of 3-way branch connection.
I-36819 67295 Draft - Need Intelligent Text Code to get BOP from a BRANCH.
Solution: #PHBOPU code now avalable.
I-45407 69940 Piping - Setting the 'Loffline' attribute for pipe sleeves.
Solution: A LOFF heading in the spec can now be used to set the LOFF
attribute.
I-46368 70105 Design - A problem in Define Template Properties Form.
Solution: Incorrect options removed from PTYPE list for SBRE SPRE and PLOT
type definitions.
I-51409 84643 Draft - Design symbols (DSYM) does not plot in config dxf/dwg.
Solution: Now works.
I-53528 88493 Design - Problem with MARK CE in Design with Equipment Templates.
I-50177 89562 HVAC - Autofill HVAC BRAN with STRT components.
I-54410 90614 Program Settings are stored in Local and not Roaming.
Solution: Add Roaming Save location.
I-53141 90796 Reporting - Project Description in Reporting.
Solution: Additional ‘Project’ attributes can be selected with ProjectInfo:
Full name, Description, Message, Number
I-54189 91825 Piping - Should be able to perform Fabrication Check by spool.
Solution: Only changed pipe spools now need to be re-validated.
I-55525, 93291, Design - Title: 3DView Grid
45097 69914 Symptoms: In a project, with supplementary, added, frames, the grid shown in
3D View window is not correct. This is not an issue in Symbols Views.
Known workaround: No known workaround exists.
Solution: The 3D grid will be displayed with correct frame numbering.
I-55788 93592 Cable - Edit Route points option on cableways using Quick routing does not work.
I-56006 93970 Design - Hole location incorrect in the Slant panel reference.
Solution: Now correct.
94257 Draft - Fatal error occurs on updating an MDS and ABA drawing, with the SHEE
open.
Solution: Explorer now checks that elements are still valid after MDS has deleted
a drawing in order to regenerate it.
I-55796 93607 Draft - Symbols do not update when the DRSSET is changed.
Solution: UPDATE DESIGN now updates the TMRF of the DESSYM.
94807 Search – ‘In Database’ dropdown is not updated after selecting an element in the
Search Filter pane.
Solution: Dropdown now correctly updated.
95584 Equipment - The Name is set to ‘unset’ on selecting the specification after
entering the name in Create Electrical Component form.
Solution: This has been corrected.
95938 Piping - Clicking on Cancel button deletes the Non-standard branch.
Solution: the system will ask for confirmation before deleting the branch.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 511 of 517
Product Release Letter
Incident Issue Description
Number Number
95956 Piping - Aborted Warning Message is displayed on Selecting the Main Branch as
the Stub in Branch from the 3D View window.
Solution: the message now warns the user that there are no intersections
between the branches.
95968 Piping – ‘Head’option fails to get displayed in the Non-Standard Branch
Connections window when the Tail of the Branch is first connected.
Solution: This has been corrected.
I-56975 96064 MEI Overwriting existing EQUI elements when importing .stp files.
Solution: Import now works consistently, and correctly confirms overwriting.
96066 Piping - Incorrect Insert Depth graphical feedback in 3D view for Non-standard
branch connection.
Solution: This has been corrected.
96069 Piping - Warning displayed on creating new non-standard branch using position
control toolbar options.
Solution: This has been improved to handle more (EDG) picking options.
I-56502 96220, HVAC - Bore vectors are not being considered when drawing implied ducting.
96008 Solution: System now handles cases where implied ducting should be drawn.
I-55818 96455 Piping - Sample mitre bend (L1PL) from /A150 is not included in the PSPOOL.
I-57196 96506 Piping - Warning Required When Insert Depth is Likely to be Erroneous.
Solution: a warning is now given.
96526 Piping - Application crashes to a fatal error if the user tries to route the pipe for
which head is connected to the nozzle of copied equipment.
Solution: this case is now handled correctly.
I-57286 96651 Isodraft - NSBC Comment should point at branch start not ghost line.
I-57314 96677 Piping - 2D Pipe Sketching does not work in Create branch function with no
graphic selection.
I-57312 96679 Structures - Title: Weight Information for BPANELs is not always correct.
Symptoms: Making holes in Bent Plates with BPOPEN will give incorrect result
of Nweight.
Known workaround: The use of BPFITT will give correct result.
Solution: Correction done so that both BPOPEN and BPFITT will give correct
result of Nweight.
96821 Piping - Incorrect warning msg displayed if the Non-standard branch is not going
to connect the main branch.
Solution: correct error message is now shown when branches do not intersect.
96913 Piping - (Utilities >Production Checks) An error message is displayed when trying
to generate PSPOOLS for pipe which is already claimed by another User.
96942 Piping - Coupling created at wrong position for Non-standard branch connection.
Solution: now navigates to the correct place before building the coupling.
97070 Structures - An Error Message is displayed on Clicking on Properties button in
the Create Hole Fittings form.
Solution: This has been corrected.
97133 Piping - Error msg displayed on selecting Boss Connection type in NSBC form if
a pipe is not from SP/DR07C spec.
Solution: This has been corrected.
I-57714 97561 Design - Outfitting Zone attribute BendMacReference Set Error.
Solution: Wider range of elements can now be referenced by BendMacRef. Also
allows PSPEC, TSPEC and ISPEC to point to a SPEC element.
I-57722 97591 Splash screen is no longer displayed.
Solution: Splash screen now appears on entry to any module.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 512 of 517
Product Release Letter
Incident Issue Description
Number Number
I-57773 97678 Equipment - MEI Import, Issue in importing as a Volume.
Solution: There is now an option to import into new volume model rather than
overwriting an existing VOLM. In this case, a new VOLM is created and named
".stp file-name + -MEI-IMPORT + INDEX", where Index is from 1 to 1000
I-57681 97699 Global Hub - Global Daemon crashes when started with a valid 8-character
Project ID.
Solution: Global Daemon now accepts an 8-character ID. An overlong Project ID
is truncated, as on the command-line only 8-character IDs are acceptable.
I-57788 97736 Isodraft - NSBC Isodraft Branch connection and notes hard to read;
Comment should point at branch start not ghost line.
Solution: Better positioned comments about non-standard branch connections.
I-57822 97804 Draft - License Check for AVEVA NET Export checkbox in Plot form.
97821 Isodraft - Extra weld is created on TEE for a Non-standard branch connection.
Solution: This has been corrected.
97827 Isodraft - Weld symbol missing at leave bore of reducer with Non-standard
branch connection.
Solution: The P3 Weld for a Reducer without a TEE has been removed.
98353 Spooler - Error message stating "(2,751) Variable!!SNEW does not exist" is
displayed when trying to Update/number spool drawing using manual data
selection.
Solution: This has been corrected.
98521 Admin (Including Lexicon & Propcon) - Problems modifying an Offline location
using Modify Location form.
Solution: Check button is now active for Online locations after modifying an
Offline location and other minor corrections.
I-58044 98557 Piping - Validation not working with atta.
Solution: This has been corrected.
I-58127 98792 General - Collection part of the Add to List form does not behave correctly.
Solution: This has been corrected for the case of an empty list.
I-58134 98804 General - Missing 'Navigate to... 'option from search results form.
Solution: This has been corrected.
98984 Piping - An error 'Undefined name /General-Tappings' is displayed when creating
new NSBC on a Tube element.
Solution: Added a warning message to reflect the lack of spec components.
I-58226 99143 General - Copy / paste using keyboard.
Solution: Duplicated ‘copy’ has been corrected.
99431 Production Checks creates PPIECEs when the start and end elements overlap.
Solution: This has been corrected by a new function to check geometry.
I-58556, 100625, Admin (Including Lexicon & Propcon) - Variant Working Extract - symbology
I-58854 101643 omits the 'V'.
Solution: These are now displayed as 'WV' rather than 'W’.
I-58587 100836 Admin (Including Lexicon & Propcon) - DICE Patch does not seem to be working
correctly on DICT DB.
Solution: Correction for elements TABA, TABB and SDET to stop incorrect
messages.
I-58604 101080, Structures - Command MARK causes PDMS fatal error.
Solution: MARK now works correctly if STEXT is UNSET.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 513 of 517
Product Release Letter
Incident Issue Description
Number Number
101248 Piping - When the main branch head bore is smaller than that of subsequent
components the list of branch bores is restricted.
Solution: The list now includes sizes up to the largest diameter in the branch.
I-58706 101311 Cats & Specs - Fixing purpose of STFX is not available when creating a new
Table Group.
Solution: This has been corrected – see 101319.
I-58710 101317 Cats & Specs - Misalignment between the Purpose and SPType attributes of a
selection table and the provided maintenance.
Solution: This has been corrected – see 101319.
I-58708 101319 Cats & Specs - Unable to set or modify the SPType for a Fixing selection Table
Group.
Solution: STFX is now an option on Create for Purpose, and on Fixing for
Discipline. Purpose is always set when a Table Group is created and SPType set
to STFX when creating a Fixing Selection Table Group.
I-58860 101675 Draft - Graphics out of Date Change.
Solution: Update Design will no longer abort scan of design graphics so that the
whole drawing will be exported, even though the exported drawing will be
imperfect. The user will see an error message to advise them.
I-59003 102179 Piping - Splmtocomp object, "element does not have attribute PPBO".
Solution: This has been corrected.
I-59271 102922 Piping - Tee place not working anymore.
Solution: This has been corrected.
I-56480 102435 Piping - The dimension and the ATTA element on the view.
I-58411 103599 Concrete Building - Creation of STWALL with Nuclear Concrete Design
generates error message.
103710 Piping - Detailed plot files required for non-standard-branch-connection
isometrics.
Solution: Detail plotfiles are automatically generated when PIPCAs are detected.
104004 Isodraft - PDMS goes to non-response mode while generating isometric for a pipe
with NSBC.
Solution: NSBC Detail Plots are added only if Display Detail Plots option is set.
104042 Piping - Error message displayed while generating Isometrics with detail plot if
the pipca's connecting branch is deleted.
104204 Piping - An error message is displayed while generating the Isometrics for pipe
with pipca when ADMIN/PADD DB is not added to MDB.
104233 Piping - Error displayed while generating isometric in isodraft for pipe with pipca
connection due to draft module definition issue in Marine.
I-59697 104409 Isodraft - Error when Creating SPLDRG Isometrics.
Solution: Detail Plots are not currently generated for Spool Drawings.
I-59881 104813 PML - Fatal error if ending ' or | is missing in import statement.
I-48690 105062 Concrete Building - Variable !AOWNER does not exist.
I-60232 106155 Clash Manager - Simple Piping Approval Rule Failure.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 514 of 517
Product Release Letter
PRODUCT QUALITY STATEMENT
The development, maintenance and testing of AVEVA Solutions’ software products is carried out
in accordance with the AVEVA Quality Management System lifecycle processes and this
document includes a summary of the testing carried out on this release and a list of significant
defects known to exist at the time of release.

Development Testing
Developers have carried out unit testing of each enhancement and/or fix in the development
environment to verify that any new functionalities have been correctly implemented and identified
defects have been corrected.

Regression tests have been run in the development environment to verify that enhancements
and/or fixes have not adversely affected the integrity of the product.

System Testing
Independent system testing has been carried out on the product, as released, to verify that it
installs correctly in all supported configurations and that product functionality operates as intended,
subject to a known exceptions listed below.

Acceptance Testing
This document has been prepared before Acceptance Testing. This product release will be
subjected to an acceptance test by Training and Product Support Team (TPS)

Any exceptions found during Acceptance Testing or after release will be reported in the Product
Release Latest Update Note on AVEVA's support web site http://support.aveva.com

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 515 of 517
Product Release Letter
Exceptions – Significant Defects and Recommended Workarounds
AVEVA intends to fix the defects listed below in a fix release or service pack as soon as
reasonably possible.

Incident Issue Description Recommended Workaround


number number
355170 Title: 12.1.SP4.55_6802: Some Attributes Known workarounds: When
In HPANBI are getting created Repeatedly searching for bevel intervals along
with 0 Values boundaries, the HPANBI attribute
Symptoms: Some Attributes in HPANBI BEVEL should be checked. If this
are getting created Repeatedly with 0 attribute returns 0 (zero), then there
Values when bevel is added to a boundary is no bevel defined for this HPANBI
via Weld statement. and it can be ignored.

Solution: Will be fixed in next fix


release.

257564 12.1.1SP4 Fix43 - Unable to add bend by Known workaround: No known


using QPR (during routing)-Bend choice workaround.
with bending machine selection.
This will be corrected in the next
possible fix release.
Title: Issues with the following fonts in Draft Known workaround: No known
Module and SVG file. workaround.

Symptoms: This will be corrected in the next


(Displayed as Capital letters) possible fix release.
Ø Technic
Ø TechnicBold
Ø TechnicLite

(Displayed with no space):


Tw Cen MT Condensed

Displays wrong font in SVG file for :


Ø MS OUTLOOK
Ø MT Extra

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 516 of 517
Product Release Letter
Incident Issue Description Recommended Workaround
number number
104589 Title: Reconfiguring a System database Known workaround: Note that
loses its Upgrade number after Reconfiguration the System
database will have lost its upgrade
Symptoms: After Reconfiguration, Q status . This can be re-applied
UPGRADE STATUS {SYSTEM|GLOBAL} using DBUPgrade
reports that an Upgrade is required, even {SYSTEM|GLOBAL} TO LATEST
though the system database had previously
been upgraded. Note that the database will Solution: Fixed in 12.1.SP5 and
not actually have been 'down-graded' by Admin 2.1 – the upgrade number is
the Reconfiguration, it is just the Upgrade re-applied.
number which has been lost.
SI- 108576, Various issue with HSPOOL due to the Set the PURP of the HVAC SPWL
60994, 111110, HVAC spec world not being recognised as (for example /CADCHVACSPECS)
SI- 111111, HVAC. These issues are typically not seen to HVAC
61731, 111112 in AVEVA sample projects supplied with
SI- 12.1.SP4 releases.
61732,
SI-61733

I-57562 97192 Pipe Fabrication, an issue has been Produce Pipe Fabrication Spool
identified when creating Spool Drawing if Drawing Prior to adding Supports.
the Pipeline contains Multi-Discipline
Supports (MDS). Corrected in 12.1.sp4.1
The Part Numbers and Spool lengths are
calculated incorrectly. It is recommended
that Spool drawings containing MDS
supports are not produced using Pipe
Fabrication.
I-57888 98279 Pipe Fabrication application: an issue for Delete the spool information from
certain pipes, for example Pipe the pipe using the Fabrication
/1MZ_FWD0002 in Zone 1MZ_PIPE Check form, do a savework then
owned by :AREA 1M_PIPE in MAR project. getwork.
Using the Component Reselection form,
changing the elbow to a bend, closing the
form and then re-opening it may cause the
application to stop responding.
[It is likely to be a problem with pipes that
contain a PSLIST.]

For the latest list of exceptions and other updates, please see the Product Release Latest Update
Note on AVEVA's support web site http://support.aveva.com .

Please refer also to the Product Release Latest Update Note for the original full release,
http://support.aveva.com.

d80460 16-Apr-2020 © Copyright 2020 AVEVA Solutions Limited Page 517 of 517

S-ar putea să vă placă și