Sunteți pe pagina 1din 3

Communication Components Inc.

Tel: 201-342-3338
Fax: 201-342-3339
Email: sales@cciproducts.com

Power Distribution and Alarm


Unit (PDU) for CCI TMA’s
Model PDU-850
Model PDU-1819
Model PDU-1819-3DT

General Information
Contents:
Communication Component Inc.’s General Info and Fea- 1
PDU-850/1819 is a DC Distribution tures/Benefits
and Alarm Unit designed to inter-
face with CCI’s Tower-top Mast- Electrical and Mechani- 2
head Amplifiers (TMA’s). It pro- cal Specifications
vides the necessary voltage and
current to power up to six CCI Block Diagrams & 3
Mechanical Drawings
TMA’s via external DC Bias Injec-
tors. The Power Distribution Unit
monitors the health of the TMA’s
and is preprogrammed with the
window of acceptable operating currents of all CCI TMA’s. LEDs and dry Options:
relay contacts indicate the operational status of each active channel. Out-  24: +24 Volt Input only
put channels are powered if a compatible TMA is connected at the time
the front panel user button is pressed or when the unit is turned on.  48: -48 Volt Input only

Features and Benefits


Communication Component Inc.’s Power Distribution Unit (PDU) is available to power up to six
tower-top masthead amplifier units and to provide the all the monitoring and alarm functions for the
system. The PDU is housed in a single (1U) 1.75” x 19” rack and contains dual redundant power
supplies that provide a regulated DC supply voltage on the RF coax for the tower-top masthead am-
plifiers.

Features and Benefits include:


 Alarm relay for each TMA plus a summary alarm
 Power supply redundancy
 Universal input range (supports both +24V or -48V input voltages)
 19 inch rack mounting

Page 1 Revision 3.0


Power Distribution and Alarm Unit (PDU) for CCI TMA’s Communication Components Inc.

Power Distribution Unit Electrical & Mechanical Specifications


Description Typical Specifications
Electrical Specifications

Input Voltage (Universal Input Unit) ±20 ~ ± 60 VDC

Input Voltage (-48 Volt Only Unit) ±38 ~ ± 60 VDC

Input Voltage (+24 Volt Only Unit) ±20 ~ ± 36 VDC

Maximum Input Current 3A

Input Protection Fuse (slow blow)

Output Voltage 12 VDC Nominal

Output Power Rating Up to 30 W

Operating Current Window Settable within 20mA ~ 700mA

TMA Status Indicators 6

GREEN Power On, TMA OK, Channel Active

AMBER TMA OFF, Channel Inactive

RED TMA Fail, Channel OFF

Power Status Indicators 1

GREEN PSU OK

RED PSU Fail or Low Voltage

Input-Output Isolation 500 VDC

Alarm Sense De-energize in FAIL state or Power off


Alarm Relay Contact Rating 0.5A @ 60 VDC

Mechanical Specifications
DC Input/Output Connectors Molex Mini-fit Junior 2-way

Summary Alarm Connector DB25 Female

Surge Protection Varistor, tranzorb network per output

Dimensions 1RU (44.45mm) high x 19” wide

Weight 1.0 KG

Environmental Specifications
Operating Temperature -20˚ C to +60˚ C (Indoor)
MTBF >400,000 hours at 22ºC

CCI Confidential
Communication Components Inc.
Tel: 201-342-3338 Fax: 201-342-3339
Page 2 Revision 3.0
Outline Drawing

Communication
Components Inc.

89 Leuning Street
South Hackensack, NJ 07606
Tel: 201-342-3338
Fax: 201-342-3339

com
Www.cciproducts.

Ordering Information:
 Model PDU-1819
 Model PDU-850
 Model PDU-1819-3DT
CEQ. 10620

Options:
 48: -48 Volt Input Only
 24: +24 Volt Input Only

Communication Components Inc.


Page 3 Revision 3.0