Fabric reinforcement:
- UPVC pipes and fittings shall comply with relevant British Standard
according to the nature of water to be conveyed and the location of the pipe.
Galvanized coatings:
- Where exposure is fairly severe
- To have smaller cover than normal in very thin section
1
Before bending of reinforcement starts:
- Bar bending schedule complying with BS4466 (superseded recently)
Fixing:
- Reinforcement shall not start until testing has been completed.
- Reinforcement shall be fixed rigidly in position and secured against
displacement, particular with respect to concreting, and shall be in
accordance with the Drawings in terms of bar sizes, spacings, shapes,
locations, lap position and length, covers, etc.
- Laps and joints shall be made at the specified location and by the specified
method only.
- Sufficient cover spacers, chairs, supports and other spacers shall be
provided
- Reinforcement shall not be welded.
2
contract requirements.
Fabric reinforcement:
- To determine the above properties as bar reinforcement, as well as the weld
shear strength.
- The batch shall be considered as non-compliance if the yield stress is less
than 93% of the specified characteristic strength
- If the yield stress lies between 93% and 100% of the specified characteristic
strength, additional samples shall be provided for additional tests, and the
whole batch shall be considered as non-compliance if the results of any
additional tests shows that the yield stress is less than 93% of the specified
characteristic strength.
- Similar to bar reinforcement, for any non-compliance in results of any test
for elongation, tensile strength, bending, rebending, unit mass, additional
samples shall be provided for additional tests. The whole batch shall be
considered as non-compliance if the results of any additional tests still fail
to comply the contract requirements.