EQUIPMENT LIST.
Class F2 - Hire & Drive Motor Vessels
(Up to Class D waters)
10 m and over Fire Bucket:
2 metal buckets with lanyard of not less than 9 litres capacity. To be painted red with “Fire” in
distinct white letters on the exterior
Less than 5 m Portable Fire Extinguishers:
1 Dry Chemical Fire Extinguisher of not less then 0.9 kg
5 m and over but Portable Fire Extinguisher:
less than 7.5 m 1 Dry Chemical Fire Extinguisher of not less than 4.5 kg.
7.5 m and over Portable Fire Extinguisher:
1 Dry Chemical Fire Extinguisher of not less than 4.5 kg. and 1 Foam Fire Extinguisher of not
less than 9 litres.
12.5 m and over Fixed Fire Extinguisher Installation - Machinery Space:
A vessel fitted with oil fired boilers or internal combustion type machinery used for main
propulsion and decked in way of the machinery space, a fixed fire extinguishing installation
complying with Appendix F of the U.S.L. Code
All Lengths Smoke Alarm:
Required in accommodation and galley
Pump Details:
In any vessel:
(b) a power pump may be driven by a main engine, an auxiliary engine or by an electric motor.
However, where two power pumps are required, each pump shall not be dependent on the
same source of power;
(c) where a vessel is required to be fitted with 2 power pumps and the capacity of one of those
pumps is less than that specified by not more than 20%, the deficiency may be made good
by an excess of capacity in the other power pump; and
(d) a bilge pump shall be of the self priming type or be provided with a suitable priming device.
Page 2 of 3 23/01/18
EQUIPMENT LIST.
Class F2 - Hire & Drive Motor Vessels
(Up to Class D waters)
A bailer of sufficient capacity and solid construction may take the place of a Manual Bilge Pump.