Compressive strength of the concrete fck : 20 mpa

Tensile strength of the steel fy : 500 mpa


Factored load P : 1650 kN
unfactored load Pw : 1100 kN
Safe Bearing Capacity sbc : 300 kN/m3
Depth of the footing D : 1.524 m
Area of the footing required A : 3.67 m3
Size of the Footing required L,B : 1.91 m
Assuming size of the footing
Length of the Footing L : 2m
Breadth of the Footing B : 2m
Depth of the footing D : 0.6 m
:
Actual Pressure on the base of the footing : 275 kN/sqm 0.775
: ok 1278.75 kNm
Column size : 8.686
Width of the column b : 0.30 m 149.015625 kNm
Depth of the column d : 0.45 m 0.775
Bending Moment along length : 7.911
Moment along depth direction Mx : 247.8 kNm 1650
Depth required d : 211.9 mm 1164.65476 kNm
Overall Depth D : 275 mm
: safe
Percentage of Ast required : 0.12 %
Area required : 1440 mm2
Diameter of the rod : 10 mm
Number of the Bars N : 19 nos
Check for Oneway shear :
Shear Force : 144.4 KN 206.3 KN
Allowable Shear Stress : 0.281 N/mm 2
0.281 N/mm2
Required Depth d : 257 mm 367 mm
D : 325 mm 425 mm
: safe safe
Bending Moment along Width :
My : 298.0 kNm
Depth required : 232 mm
D : 300 mm
: safe
Percentage of Ast required : 0.12 %
Area required : 1440 mm2
Diameter of the rod : 10 mm
Number of the Bars N : 19 nos
Punching Shear :
Shear V : 1650 kN
Effective Width : 3.9 m
coefficient k : 1.00
Maximum shear stress tc : 1.12
Depth required drq : 378 mm
safe