Factored load P : 1650 kN unfactored load Pw : 1100 kN Safe Bearing Capacity sbc : 300 kN/m3 Depth of the footing D : 1.524 m Area of the footing required A : 3.67 m3 Size of the Footing required L,B : 1.91 m Assuming size of the footing Length of the Footing L : 2m Breadth of the Footing B : 2m Depth of the footing D : 0.6 m : Actual Pressure on the base of the footing : 275 kN/sqm 0.775 : ok 1278.75 kNm Column size : 8.686 Width of the column b : 0.30 m 149.015625 kNm Depth of the column d : 0.45 m 0.775 Bending Moment along length : 7.911 Moment along depth direction Mx : 247.8 kNm 1650 Depth required d : 211.9 mm 1164.65476 kNm Overall Depth D : 275 mm : safe Percentage of Ast required : 0.12 % Area required : 1440 mm2 Diameter of the rod : 10 mm Number of the Bars N : 19 nos Check for Oneway shear : Shear Force : 144.4 KN 206.3 KN Allowable Shear Stress : 0.281 N/mm 2 0.281 N/mm2 Required Depth d : 257 mm 367 mm D : 325 mm 425 mm : safe safe Bending Moment along Width : My : 298.0 kNm Depth required : 232 mm D : 300 mm : safe Percentage of Ast required : 0.12 % Area required : 1440 mm2 Diameter of the rod : 10 mm Number of the Bars N : 19 nos Punching Shear : Shear V : 1650 kN Effective Width : 3.9 m coefficient k : 1.00 Maximum shear stress tc : 1.12 Depth required drq : 378 mm safe