Sunteți pe pagina 1din 10

Series 2000 Instruments

LM2-CLMD - Replacement Display for


CLM200 and CLM220 Installation Guide

42TM20-31
Revision A
© Copyright 2009 National Oilwell Varco LP. All rights reserved.

NOV is a registered trademark of National Oilwell Varco I/P, Inc. Registered U.S. Patent & Trademark
Office. This publication is the property of, and contains information proprietary to, National Oilwell Varco,
Inc. No part of this publication may be reproduced or copied in any form, or by any means, including
electronic, mechanical, photocopying, recording, or otherwise without the prior written permission of
National Oilwell Varco, Inc. All product, brand, or trade names used in this publication are the
trademarks or registered trademarks of their respective owners.

Information in this manual is subject to change without notice.


LM2-CLMD Installation Guide

Overview
The LM2-CLMD has been designed to retrofit the CLM220/200 unit
display, and has been specifically configured to replace the original
CLM display unit. The LM2-CLMD is designed for mounting on a
customer supplied console. Install the unit using the instructions
listed below.

Installation Parts Index

Replacement Display Parts

Item Part No. Description Qty

220870- DISPLAY ASSY, REPL,


1 1
CLMD CLM220/200

220898- ENCL ASSY, DISPLAY


2 1
CLMD REPLACEMENT,

3 H10555A JUMPER, BERG 2

40225594- STANDOFF, M/F, 1/4-20X2.4,


4 2
001 RND

BAG,PK POLY, ZIPLK, 4MIL, 2-


5 999429-008 3
1/2X3

6 X10351A BAG, CLOTH,5"X7" 1

MANUAL CLM, QUICK REF


7 42TM20-31 1
GUIDE

8 999429-006 BAG, ZIPLOCK 9 X 12 1

42TM20-31 1-1
Quick Reference Guide

Installation
The LM2-CLMD has a new bracket in the installation kit that can be
used to install the unit. If the existing original CLM220/200 bracket
cannot be removed, the installation kit has adaptors to allow the LM2-
CLMD to fit in the existing bracket. The following installation steps
show how to install the LM2-CLMD using the existing bracket and
instructions for the new bracket, depending on which type of
installation is being done. Power down the CLM220/200 main CPU
unit prior to installation of the LM2-CLMD and perform the steps
below:
1. If not already done, disconnect cable (MDT P/N XC040-30)
from old CLM 220/220 display. Remove the old display from
the bracket and remove the bracket, if applicable.
2. If the replacement bracket is to be used, secure the bracket
with nuts and bolts or by welding it into the desired location.
3. If the existing bracket is being used, screw the adapters to the
display. If the new bracket provided in the kit is being used, skip
this step.
Adapters

ExistingExisting
BracketBracket

Replacment Bracket

1-2 National Oilwell Varco


Quick Reference Guide

4. If the existing bracket is being used, place the display in the


existing bracket by inserting the threaded adapter ends through
the top holes on each end of the bracket and proceed to step
six.

5. If the replacement bracket is being used, insert the threaded


ends into the top holes of the new bracket.

6. If the existing bracket is being used secure the display by


screwing the knobs onto the adapter ends.

42TM20-31 1-3
Quick Reference Guide

7. If the replacement bracket is being used secure the display by


screwing the knobs onto the adapter ends.

1-4 National Oilwell Varco


Quick Reference Guide

Electrical Installation
The connection between the CPU and display is accomplished as
outlined below:
1. On the circuit board of the CLM220 main CPU (usually
mounted on the crane cabin wall) place the Berg jumper (P/N
H10555A) on JP6 as seen in Figure 1-1.

Figure 1-1. Circuit Board of CLM220

Note: The Berg jumper included in the installation kit is


required to provide the correct supply voltage to the LM2-
CLMD.

2. To connect the existing cable (NOV M/D Totco P/N XC040-30)


cable from the CML220 CPU to the LM2-CLMD:
a. Remove the back cover of the LM2-CLMD.
b. Insert the cable through the cable gland on LM2-CLMD
back cover.
c. Terminate the wires of the existing display cable on the
back panel of the LM2-CLMD as shown in Figure 1-2 .

42TM20-31 1-5
Quick Reference Guide

Existing wire jumper


(already installed)

Cable

Figure 1-2. Wiring on Back Panel of LM2-CLMD.

Figure 1-3. Wiring Diagram

3. Reinstall LM2-CLMD back cover and tighten gland.

Caution: Power input and output wiring shall be in accordance


with Class I Division 2 wiring methods, Article 501-4
(b) of the National Electric Code, NFPA 70 for
installations in the United States, or as specified in
Section 18-1J2 of the Canadian Electrical Code for
installations within Canada, and in accordance with
the authority having jurisdiction.

Warning: Explosion Hazard - Do not disconnect


equipment unless power has been switched off or
the area is known to be non-hazardous.

1-6 National Oilwell Varco


Quick Reference Guide

42TM20-31 1-7
Quick Reference Guide

1-8 National Oilwell Varco