Sunteți pe pagina 1din 2

Residential Power Vent Gas Water Heater

The TTW ® Models Feature:


■ ENERGY STAR® Qualified—Some models meet or exceed requirements for ENERGY
STAR® per the latest ENERGY STAR® criteria revision, as well as most utility rebate
programs.
■ Powerful Blower Motor—Exclusively featuring the AquaVENT MAX™ from Fasco™ is the
quietest blower motor in the industry. This new blower is a lower profile than previous
versions and features a more robust electrical connection.
-- Ten Foot (3 meter) Power Cord—Included (120 VAC).
■ Horizontal and Vertical Venting—Designed for installations where atmospheric units
cannot be used. Exhaust gases are vented under positive pressure directly out of the
building through the roof or the wall with PVC, ABS or CPVC (Maximum equivalent vent
length on reverse side).
■ Bradford White ICON System™—Intelligent gas control with spark to pilot ignition system
eliminates the constant burning pilot. This results in savings of pilot gas during standby periods
(120 VAC).
-- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Rating and
tighter temperature differential.
-- Advanced Temperature Control System—Microprocessor constantly monitors and controls
burner operation to maintain consistent and accurate water temperature levels.
-- Intelligent Diagnostics—An exclusive green LED light prompts the installer during start-up
and provides ten different diagnostic codes to assist in troubleshooting.
-- Pilot On Indication—Flashing green LED provides positive indication that pilot is on.
-- Separate Immersed Thermowell—High-strength advanced polymer composite thermowell
provides isolation between electric temperature sensor and surrounding water. No need to
drain the tank when removing gas valve.
■ Advanced ScreenLok® Technology Flame Arrestor Design—Flame arrestor is designed
to prevent ignition of flammable vapor outside of the water heater (excluding RG1PV55H6N
& RG2PV75H6N).
■ Flammable Vapor Sensor—Electronic sensor prevents burner operation if flammable
vapors are detected. The sensor will also prevent operation if there is ongoing flammable
vapors burning inside the combustion chamber (excluding RG1PV55H6N & RG2PV75H6N).
■ Maintenance-Free—No regular cleaning of air inlet openings or flame arrestor is required
under normal conditions (excluding RG1PV55H6N & RG2PV75H6N).
■ Sight Window—Offers a view into the combustion chamber to observe the operation of the
pilot and burner.
■ Factory-Installed Hydrojet® Total Performance System—Sediment reducing device that
also increases first hour rating of hot water while minimizing temperature build-up in tank.
Photo is of ■ Vitraglas® Lining—An exclusively engineered enamel formula that provides superior tank
protection from the highly corrosive effects of hot water. This formula (Vitraglas®) is fused to
RG2PV50T6N the steel surface by firing at a temperature of over 1600°F (871°C).
FEATURING: ■ Insulation System—Non-CFC foam covers the sides and top of the tank, reducing heat
loss. This results in less energy consumption, improved efficiencies, and jacket rigidity.
■ Water Connections—3⁄4" (19mm) NPT factory-installed true dielectric fittings extend water
heater life and simplify water line connections.
■ 3/4" (19mm) NPT Side Connections—(RG2PV50H6N, RG1PV55H6N, and RG2PV75H6N
only).
■ Factory-Installed Heat Traps—Design incorporates a flexible disk that reduces heat loss in
piping and eliminates the potential for noise generation.
■ Protective Magnesium Rod—(RG1PV55H6N has 2).
■ T&P Relief Valve—Installed.
■ Thermostatic Mixing Valve (ASSE Approved)—Included (RG1PV55H6N only).
■ Low Restrictive Brass Drain Valve—Durable tamper proof design.
■ NOx Emissions—Less than 40 ng/J.

6 or 10-Year Limited Tank Warranties / 6 or 10-Year Limited Warranty on Component Parts.


For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.

MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 7,334,419;
7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379;
7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958;
2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System®, ScreenLok®, TTW®, Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation.
1261-E-0120
Residential Power Vent Gas Water Heater
TTW® Power Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
NATURAL GAS AND LIQUID PROPANE GAS 80% Recovery Efficiency

Model Nominal DOE Recovery at Model Nominal DOE Recovery at


Number Gal. Rated First 90°F Rise* Number Liter Rated First 50°C Rise*
Capacity Storage LP Hour Uniform LP LP Capacity Storage LP Hour Uniform LP
U.S. Imp. Volume BTU/Hr. BTU/Hr. Rating Energy U.S. Imp. U.S. Imp. Volume kW kW Rating Energy Liters/ Liters/
Gal. Gal. (Gal.) Input Input (Gal.) Factor GPH GPH GPH GPH (Liters) Input Input (Liters) Factor Hour Hour Liters
★ RG1PV40S6N 40 33 38 40,000 38,000 75 0.68 43 36 41 34 ★ RG1PV40S6N 151 144 11.7 11.1 284 0.68 163 155
★ RG1PV50S6N 50 42 48 40,000 38,000 78 0.69 43 36 41 34 ★ RG1PV50S6N 189 182 11.7 11.1 295 0.69 163 155
★ RG2PV40S6N 40 33 38 40,000 38,000 75 0.72 43 36 41 34 ★ RG2PV40S6N 151 144 11.7 11.1 284 0.72 163 155
★ RG2PV50S6N 50 42 48 40,000 38,000 78 0.72 43 36 41 34 ★ RG2PV50S6N 189 182 11.7 11.1 295 0.72 163 155
★ RG2PV40T6N 40 33 38 40,000 40,000 78 0.72 43 36 43 36 ★ RG2PV40T6N 151 144 11.7 11.7 295 0.72 163 163
★ RG2PV50T6N 50 42 48 40,000 40,000 75 0.72 43 36 43 36 ★ RG2PV50T6N 189 182 11.7 11.7 284 0.72 163 163
★ RG2PV50H6N 48 42 46 65,000 58,000 116 0.68 70 58 62 52 ★ RG2PV50H6N 182 174 19.1 17.0 440 0.68 265 235
RG1PV55H6N 55 46 55 78,000 78,000 125 0.68 84 70 84 70 RG1PV55H6N 208 208 22.9 22.9 474 0.68 318 317
RG2PV75H6N 75 62 72 76,000 75,500 121 0.69 82 68 81 67 RG2PV75H6N 284 235 22.3 22.1 459 0.69 310 307

Model A B C D E F G H J K L M R S Approx.
Number Floor to Jacket Vent Floor to Floor to Floor to Floor to Depth C/L Floor to Floor to Water Space Gas Shipping
Top of Dia. Size T&P Gas Top of Water of Water Space Heating Space Heating Conn. Heating Conn. Weight
Blower Conn. Conn. Heater Conn. Conn. Inlet Outlet NPT Conn. Size Size
in. in. in. in. in. in. in. in. in. in. in. in. in. in. lbs.
★ RG1PV40S6N 55 7/16 20 2 or 3 40 11 1/2 46 1/2 49 25 15/16 8 N/A N/A /
34 N/A /
12 140
★ RG1PV50S6N 56 3/8 22 2 or 3 40 5/8 11 1/2 48 3/16 50 1/2 27 3/16 8 N/A N/A 3/4 N/A 1/2 166
★ RG2PV40S6N 55 7/16 22 2 or 3 40 1/8 11 1/2 47 3/16 49 27 3/16 8 N/A N/A 3/4 N/A 1/2 142
★ RG2PV50S6N 56 7/16 24 2 or 3 40 5/8 11 1/2 48 3/16 50 1/2 28 7/8 8 N/A N/A 3/4 N/A 1/2 168
★ RG2PV40T6N 65 20 2 or 3 49 11/16 11 1/2 56 3/4 58 26 1/8 8 N/A N/A 3/4 N/A 1/2 146
★ RG2PV50T6N 65 13/16 22 2 or 3 50 9/16 11 1/2 57 9/16 58 27 3/16 8 N/A N/A 3/4 N/A 1/2 173
★ RG2PV50H6N 66 1/2 22 3 or 4 49 7/8 11 1/2 56 3/4 57 3/4 26 15/16 11 13 3/8 49 7/8 3/4 3/4 1/2 187
RG1PV55H6N 64 9/16 22 3 or 4 47 15/16 11 1/2 54 3/4 56 27 3/16 7 3/ 4 13 3/8 47 15/16 3/4 3/4 1/2 219
RG2PV75H6N 69 1/2 26 3 or 4 51 15/16 13 15/16 59 11/16 60 3/4 30 11/16 11 16 11/16 5115/16 3/4 3/4 1/2 260

Model A B C D E F G H J K L M R S Approx.
Number Floor to Jacket Vent Floor to Floor to Floor to Floor to Depth C/L Floor to Floor to Water Space Gas Shipping
Top of Dia. Size T&P Gas Top of Water of Water Space Heating Space Heating Conn. Heating Conn. Weight
Blower Conn. Conn. Heater Conn. Conn. Inlet Outlet NPT Conn. Size Size
mm. mm. mm. mm. mm. mm. mm. mm. mm. mm. mm. mm. mm. mm. kg.
★ RG1PV40S6N 1408 508 51 or 76 1016 292 1181 1245 659 203 N/A N/A 19 N/A 13 64
★ RG1PV50S6N 1432 559 51 or 76 1032 292 1224 1283 691 203 N/A N/A 19 N/A 13 75
★ RG2PV40S6N 1408 559 51 or 76 1019 292 1199 1245 691 203 N/A N/A 19 N/A 13 64
★ RG2PV50S6N 1408 610 51 or 76 1032 292 1244 1283 733 203 N/A N/A 19 N/A 13 76
★ RG2PV40T6N 1651 508 51 or 76 1262 292 1441 1473 664 203 N/A N/A 19 N/A 13 B 66
★ RG2PV50T6N 1672 559 51 or 76 1284 292 1462 1473 691 203 N/A N/A 19 N/A 13M 78
H
★ RG2PV50H6N 1689 559 76 or 102 1267 292 1441 1467 684 279 340 1267 19 19 13 85
RG1PV55H6N 1640 559 76 or 102 1218 292 1391 1422 691 197 340 1218 19 J
19 13 99
RG2PV75H6N 1689 660 76 or 102 1319 354 1516 1543 779 279 424 1319 19 M 19 13 118
Propane models feature a Titanium Stainless Steel propane burner. For Propane
(LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6”
to “10” (Not available on RG1PV55H6N). *Based on manufacturer’s rated recovery C
efficiency. 120 VAC Required for Power Venting / 120 VAC, 60Hz., 3.1 Amperes.
Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory
B
listings. M
H
H = ENERGY STAR® Qualified.
J
RG2PV40S6N RG1PV50S6N RG2PV50H6N
RG2PV50S6N RG2PV40T6N 2" 3" RG1PV55H6N 3" 4" M
RG1PV40S6N RG2PV50T6N Vent Pipe Vent Pipe RG2PV75H6N Vent Pipe Vent Pipe
Max. Equivalent Length †50 ft. †120 ft. Max. Equivalent Length †50 ft. †180 ft.
G
Min. Equivalent Length 7 ft. 15 ft. Min. Equivalent Length 7 ft. 15 ft. C
A
Number 1 45 ft. 115 ft. Number 1 45 ft. 175 ft.
of 2 40 ft. 110 ft. of 2 40 ft. 170 ft. F
90° Elbows 3 35 ft. 105 ft. 90° Elbows 3 35 ft. 165 ft. D

Subtract 5ft. (1.5m) for each additional 90° elbow


S
† For high altitude installations, consult the installation instructions.
General: Meets NAECA or EPACT Requirements, as applicable. All gas water heaters are certified at 300 PSI
(2068 kPa) test pressure and 150 PSI (1034 kPa) working pressure. All water connections are 3⁄4" (19mm) NPT, E
G
all gas connections are 1⁄2" (13mm). All models design-certified by CSA International (formerly AGA/CGA), ANSI
A
Z21.10.1 and/or Z21.10.3 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with F our policy of continuous product improvement.
D
Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this
system. This unit may NEVER be connected to any existing heating system or component(s) previously
S
used with a non-potable water heating appliance.

For field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 n Fax 215-641-1612
E
Technical Support 800-334-3393 n Email techserv @bradfordwhite.com
Ambler, PA Warranty 800-531-2111 n Email warranty@bradfordwhite.com
International: Telephone 1-215-641-9400 n Email international@bradfordwhite.com / www.bradfordwhite.com

1261-E-0120 ©2020, Bradford White Corporation. All rights reserved. Printed in U.S.A.

S-ar putea să vă placă și