Sunteți pe pagina 1din 11

Simplified Interaction Diagrams©

for Single and Bi-axial moments


Using the Ultimate Limit Design Method
according to the ECP 203-2017

Ver. 2.3

Please send your comments & suggestions to improve this tool on


melkateb@hotmail.com

by
Mahmoud M. El-Kateb, Ph.D

Structural Engineering Dept.


Faculty of Engineering - Ain Shams University
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 2.3

* Calculation of Interaction Diagram

* Project :

Concrete fcu = 25 MPa


Steel fy = 400 MPa

As1 As3 As2

Nu
b + Mu

Section Sec. dim. Reinforcement


Properties b (mm) t (mm) As1 As2 As3
C1 300 600 4 f 16 4 f 16 6 f 16
Cover = 30 mm

Straining actions:
on Long direction only on Short direction only
Mu (kN.m) Nu (kN) Mu (kN.m) Nu (kN)
200 , 1200 100 , 1200
150 , 1400 70 , 1300
Long direction Short direction Mu

4 f 16 3 f 16 4 f 16 4 f 16 3 f 16 4 f 16

Nu Nu
0.30 + Mu 0.30
+

3 f 16 3 f 16

Page 2/11
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 2.3
0.60 0.60

Buckling conditions:

Long direction Short direction


Height of column = 5 m 3 m
Type of building: Unbraced Unbraced
Height factor = 1.3 Case 1-2 1.2 Case 1-1
Slenderness ratio l = 10.8 Long column 12.0 Long column
d= 35.2 mm 21.6 mm

Check the safety of:


on Long direction only on Short direction only
Mu (kN.m) Nu (kN) Mu (kN.m) Nu (kN)
242 , 1200 126 , 1200
199 , 1400 98 , 1300

Interaction Diagram Interaction Diagram


Axial load Nu (kN)

Axial load Nu (kN)


3000 3000

2500 2500

2000 2000

1500 1500

1000 1000

500 500

0 0
0 50 100 150 200 250 300 0 20 40 60 80 100 120 140 160
-500 -500

-1000 -1000

-1500 -1500
Bending Moment Mu (kN.m) Bending Moment Mu (kN.m)

Page 3/11
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 2.3

C1

Page 4/11
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 2.3

* Column under Bi-axial Moment using Equivalent Moment


for columns with uniformly distributed reinforcement

* Project :

Concrete fcu = 25 MPa


Steel fy = 400 MPa

Mux
As1 As3 As2

Nu
b + Muy

Section Sec. dim. Reinforcement


Properties b (mm) t (mm) As1 As2 As3
C1 300 700 4 f 16 4 f 16 8 f 16
Cover = 30 mm

Straining actions:

Nu (kN) Mux (kN.m) Muy (kN.m) Dominating M Mu`


1200 50 150 My 247.5
1500 100 50 Mx 147.7

Long direction Short direction Mux`

4 f 16 4 f 16 4 f 16 4 f 16 4 f 16 4 f 16

Nu Nu
0.30 + Muy` 0.30
+

4 f 16 4 f 16

Page 5/11
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 2.3

0.70 0.70

Buckling conditions:

Long direction Short direction


Height of column = 3 m 3 m
Type of building: Unbraced Unbraced
Height factor = 1.3 Case 1-2 1.2 Case 1-1
Slenderness ratio l = 5.6 Short column 12.0 Long column
d= 0.0 mm 21.6 mm

Check the safety of:


on Long direction on Short direction
Muy` (kN.m) Nu (kN) Mux` (kN.m) Nu (kN)
247 , 1200 0 , 0
0 , 0 148 , 1500

Simplified Interaction Diagram Simplified Interaction Diagram


Axial load Nu (ton)

Axial load Nu (ton)


3000 3000

2500 2500

2000 2000

1500 1500

1000 1000

500 500

0 0
0 50 100 150 200 250 300 350 400 0 20 40 60 80 100 120 140 160 180
-500 -500

-1000 -1000

-1500 -1500
Bending Moment Muy (m.t) Bending Moment Mux (m.t)

Page 6/11
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 2.3

C1

Page 7/11
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 2.2

* Column under Bi-axial Moment

* Project :

Concrete fcu = 40 MPa


Steel fy = 400 MPa
required
Col. Mx/(fcu.t.b2) My/(fcu.b.t2) r m (%)
C1 0.05 0.04 4 1.6%

Interaction Diagram for Biaxially Loaded Columns, Rb = 0.30

0.15

0.14

0.13

0.12
Mx/(fcu.t.b2)

0.11

0.1

0.09

0.08

0.07

0.06

0.05

0.04

0.03

0.02

0.01

0
0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 0.11 0.12 0.13 0.14 0.15
My/(fcu.b.t2)

Rb=0.3
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 2.2

* Column under Bi-axial Moment

* Project :

Concrete fcu = 40 MPa


Steel fy = 400 MPa
required
Col. Mx/(fcu.t.b2) My/(fcu.b.t2) r m (%)
C1 0.05 0.04 6.4 2.6%

Interaction Diagram for Biaxially Loaded Columns, Rb = 0.40

0.12

0.11

0.1
Mx/(fcu.t.b2)

0.09

0.08

0.07

0.06

0.05

0.04

0.03

0.02

0.01

0
0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 0.11 0.12
My/(fcu.b.t2)

Rb=0.4
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 2.2

* Column under Bi-axial Moment

* Project :

Concrete fcu = 40 MPa


Steel fy = 400 MPa
required
Col. Mx/(fcu.t.b2) My/(fcu.b.t2) r m (%)
C1 0.03 0.025 7 2.8%

Interaction Diagram for Biaxially Loaded Columns, Rb = 0.50

0.08

0.07
Mx/(fcu.t.b2)

0.06

0.05

0.04

0.03

0.02

0.01

0
0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08
My/(fcu.b.t2)

Rb=0.5
Reinforced Concrete design according to ECP 203-2017 By: Dr. Mahmoud El-Kateb
Version 2.2

* Column under Bi-axial Moment

* Project :

Concrete fcu = 40 MPa


Steel fy = 400 MPa
required
Col. Mx/(fcu.t.b2) My/(fcu.b.t2) r m (%)
C1 0.03 0.02 9.5 3.8%

Interaction Diagram for Biaxially Loaded Columns, Rb = 0.60

0.07

0.06

0.05
Mx/(fcu.t.b2)

0.04

0.03

0.02

0.01

5.20417042793042E-18
1 8 01 02 03 04 05 06 07
0 .0 -1 0. 0. 0. 0. 0. 0. 0.
- E
0 42
-0.01
3
2 79
4
1 70
4
. 20
5
My/(fcu.b.t2)

Rb=0.6

S-ar putea să vă placă și