Performance Test Data for

Epoxy Novalac Ceilcote 2000 Flakeline


Test Type Test Method Specification Details Typical Results

Abrasion ASTM D4060 - "Abrasion Consult Installation Average of 210-220mg weight loss per
Resistance of Coatings via Procedure 1000 cycles using CS17 wheels and a
the Taber Abraser" 1Kg loading.

Cathodic ASTM G95 - "Cathodic 2 x 500µm Ceilcote 2000 < 5mm adhesive disbondment and <
Disbondment disbondment test of pipeline Flakeline 4mm cathodic disbondment after 30 days
coatings (attached cell @ 50°C
method)"

Cathodic ASTM G8 - "Cathodic 2 x 500µm Ceilcote 2000 < 2mm adhesive disbondment after 30
Disbondment Disbonding of Pipeline Flakeline days @ 25°C. Typically no cathodic
Coatings" , Method A @ -1.5 disbondment
volts

Coefficient of ASTM C531 -"Linear Consult Installation 18.7X10-6 /°F (33.7X10-6 /°C)
Linear Expansion Shrinkage and Coefficient of Procedure
Thermal Expansion of
Chemical-Resistant Mortars,
Grouts, Monolithic
Surfacings, and Polymer
Concretes"

Coefficient of ASTM D696 - "Coefficient of Consult Installation 20 x 10E-6 /°F (34x10E-6 /°C)
Linear Expansion Linear Thermal Expansion of Procedure (Reinforcement layer)
Plastics Between -30C and
30C With a Vitreous Silica
Dilatometer"

Compressive ASTM D695 - "Compressive Consult Installation 66.2 MPa (9,600 psi)
Strength Properties of Rigid Plastics" Procedure

Density ASTM D1475 - "Density of Consult Installation 1.10 - 1.14 kg/litre (9.14 - 9.54 lbs/gal)
Liquid Coatings, Inks, and Procedure
Related Products"

Flexural Strength ASTM D790- "Test Methods Consult Installation 20 MPa (3,000 psi)
for Flexural Properties of Procedure
Reinforced Plastics"

Immersion ISO 2812 Part 2 - "Resistance 1 x 500µm Ceilcote 2000 No blistering , rusting or cracking
to liquids - Sea Water @ Flakeline following 9 months exposure
60°C"

Immersion ISO 2812 Part 2 - "Resistance 1 x 500µm Ceilcote 2000 No blistering, rusting or cracking
to liquids - Deionised Water Flakeline following 9 months exposure
@ 60°C"

Service In-House Test: Continuous Consult Installation 121°C (250°F)


Temperature Dry Procedure
Limits

Test Performance Results were obtained in a controlled laboratory environment, as specified in the Test Method. International Protective Coatings makes
no representation that the exhibited published test results, or any other tests, actually represent results found in all field environments

Page 1 of 2
Protective Coatings 24/07/2012
All products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale.
Registered in England No. 63604
Registered Office 26th Floor, Portland House, Bressenden Place, London SW1E 5BG
Performance Test Data for
Epoxy Novalac Ceilcote 2000 Flakeline
Test Type Test Method Specification Details Typical Results

Service In-House Test: Consult Installation 49°C (120°F)


Temperature Immersion/Condensing Procedure
Limits Fumes

Tensile Strength ASTM D638 - "Tensile Consult Installation 23 MPa (3,400 psi)
Properties of Plastics" Procedure

Viscosity (Mixed) ASTM D2393 - "Viscosity of Consult Installation 9,000 - 11,000 cps @ 25°C (77°F)
Epoxy Resins and Related Procedure
Components"

Test Performance Results were obtained in a controlled laboratory environment, as specified in the Test Method. International Protective Coatings makes
no representation that the exhibited published test results, or any other tests, actually represent results found in all field environments

Page 2 of 2
Protective Coatings 24/07/2012
All products supplied and technical advice or recommendations given are subject to our standard Conditions of Sale.
Registered in England No. 63604
Registered Office 26th Floor, Portland House, Bressenden Place, London SW1E 5BG

S-ar putea să vă placă și