Product Data Sheet

LNL-600XA
13.8VDC 8A/27.6VDC 4A Switched Mode Power Supply with enclosure

Product Overview

The new Lenel access control range of switch mode power


supplies has been specifically designed to house all common
Lenel access control door controllers & modules. With different
power options and enclosure sizes the range provides a
solution for up to a 12 Lenel controllers/modules (refer to the
manual for all the different combinations). The modular
construction simplifies maintenance.
All PSU models offer fault signalling and can charge a 12VDC
standby battery to provide backup power on a mains failure.
Multi-fused outputs are provided to allow the installer to protect
individual circuits as required. All models possess a mains fail
relay output while the LNL-200XA and LNL-400XA models also
offer additional Battery Monitoring and Deep Discharge
Protection to prevent premature battery failure when operating
in standby mode for extended periods. Standard Features
The LNL-600XA is provided with a unique hinged cabling
system and can provide either 12VDC or 24VDC whilst also E Enclosure (white with Lenel logo)
offering an independent ancillary relay that can be used for E PCB standoffs supplied for housing several Lenel controller/
applications such as a ‘Fire’ door release relay. The relay offers modules
Normally Open or Normally Closed contacts. E Cost effective switch mode technology
The products use energy efficient switch mode technology and E Front & rear enclosure tampers
therefore have a universal mains supply input (90 - 264VAC). E Mains Fail relay output
The range consists of: E Battery Monitoring (LNL-200XA / LNL-400XA)
E Volt-free fault outputs (LNL-200XA / LNL-400XA)
LNL-200XA: 13.8VDC 2A with enclosure (to fit 1x LNL-1300e + E Deep discharge protection (LNL-200XA / LNL-400XA)
LNL1300 or a LNL-2210) E Independent ancillary relay (LNL-600XA)
E Selectable 13.8V / 27.6VDC output (LNL-600XA)
LNL-400XA: 13.8VDC 4A with enclosure (to fit a range of up to E Full rated current to load + 0.5A battery charging
4 Lenel controllers/modules) E 90 to 264VAC range
E Electronic overload protection
LNL-600XA: 13.8VDC 8A / 27.6VDC 4A with enclosure E Mains transient protection
including LNL-600XA-SET (to fit a range of up to 12 Lenel E PSU status LED’s (mains present & fault)
controllers/modules) E Steel - white powder coated inside and outside enclosure
E Tripple US gang box compatible
LNL-200XA-ENC: Empty Enclosure for LNL-200XA-PSU E Installer safe design with all high voltage electronics fully
shrouded
LNL-400XA-ENC: Empty Enclosure for LNL-400XA-PSU E 3 Year warranty

LNL-600XA-ENC: Empty Enclosure for LNL-600XA-PSU

LNL-600XA-SET: 2 Hinged Expansion Plates Sets for


LNL600XA-ENC

LNL-200XA-PSU: 13.8VDC 2A PSU Module for LNL-200XA-


ENC Enclosure

LNL-400XA-PSU: 13.8VDC 4A PSU Module for LNL-400XA-


ENC Enclosure

LNL-600XA-PSU: 13.8VDC 8A / 27.6VDC 4A PSU Module for


LNL-600XA-ENC Enclosure

LNL-FUSE-8: 8-way Fused Output Board with LED's for


LNL-600XA
13.8VDC 8A/27.6VDC 4A Switched Mode Power Supply with enclosure
LNL-600XA
Ordering Information
Specifications Part No. Description
Input Specifications LNL-200XA 13.8VDC 2A Switched Mode Power Supply with enclosure for
LNL boards
Voltage (rated) 100-240VAC
Voltage (operating) 90-264VAC LNL-400XA 13.8VDC 4A Switched Mode Power Supply with enclosure for
LNL boards
Frequency 50-60Hz
Max Current 2A (@ 90VAC) LNL-600XA 13.8VDC 8A/27.6VDC 4A Switched Mode Power Supply with
enclosure
Mains Input Fuse T3.15A (20mm 250VAC HBC)
Max standby Power 1.5W (No load and no battery connected) LNL-600XA-ENC
Output Specification
LNL-600XA-PSU
13.5 – 14.0VDC (13.8VDC nominal) on mains
Voltage - 12V Mode power
LNL-FUSE-8
Voltage - 12V Mode 10.5 – 12.4VDC on battery standby
27.0 – 28.0VDC (27.6VDC nominal) on mains LNL-600XA-SET
Voltage - 24V Mode power
Voltage - 24V Mode 21.0 – 24.7VDC on battery standby
Fused Output Module 8 x F1.0A
Max load current 8A
Ripple 100 mV pk-pk max
Load output Fuse (Module) F8.0A
Electronic shutdown (mains operation) and fuse
Overload protection. Battery protection by self-resetting
thermal fuse.
Rating Class 2 Rated
Battery
Battery Type One or two 12VDC Valve Regulated Lead Acid
Battery Capacity 12V Mode 1x BS131N or 18Ah (max)
Battery Capacity 24V Mode 2 x BS127N or 8Ah (max)
Battery Charging Fuse 0.5A thermal fuse (self-resetting)
protection
MTBF 100,000 Hrs
Mechanical
Dimensions w x h x d 478 x 515 x 146
(mm)
1x BS131N or 18Ah (max), or 2 x BS127N or
Battery Capacity 8Ah (max)
Weight 10.5Kg
Enclosure Material Steel - white (RAL9003) powder coated
Tamper Front and rear tamper
Locks with keys Yes, 2 locks with each 2x keys
IP & IK rating IP30 / IK08
Environmental
Operating temperature -10 to +40°C 75% RH non-condensing
Storage temperature -20 to +80°C
Compliance
Low Voltage 2014/35/EU
EMC 2014/30/EU
WEEE 2012/19/EU
RoHs2 2011/65/EU
CE CE Marked

As a company of innovation, UTC Fire & Security reserves the right to change product