Sunteți pe pagina 1din 4

STABILITY CHECK

1 Check for Stability at Bed Level (When the u/s water is at Crest Level and there is no flow downsteam)

Top width, a = 3.00 m


Bottom width, b = 4.50 m
Height of checkdam, Ht = 3.50 m
Density of Concrete, ɤc = 24.00 KN/m³
Density of Water, ɤw = 10.00 KN/m³
Crest Level
a=3

a=3
Ht = 3.5 1
b = 4.5
Ht = 3.5
3 2
Bed Level
O
b = 4.5

V - Vertical Force H - Horz Force Lever Arm Mo MR


Sl.No Ref Particulars
KN KN m KN.m KN.m
1 1 Body wall 252.000 3.000 0.000 756.000
2 2 Body wall 63.000 1.000 0.000 63.000
3 3 Water Pr 61.250 1.167 71.458 0.000
315.000 61.250 71.458 819.000

Resultant Force acts at distance of (ẍ from O) (MR - MO) / V = 2.373 m


Eccentricity (e) |b/2- ẍ| = 0.123 m
Maximum Bending Stress Pmax V/b (1+6e/b) = 81.48 KN/m2
Minimum Bending Stress Pmin V/b (1-6e/b) = 58.52 KN/m2
Permissible Compressive stress 7000 KN/m2
Permissible Tension stress -530 KN/m2
Factor of Safty (Overturning) FSO MR/MO = 11.461 (must be >2.0)
Factor of Safty (Sliding) FSS 0.6V/H = 3.086 (must be >1.5)
As Maximum Bending Stress is within permissible limit, it is Safe
Tension within Limits, Hence Safe
Factor of safty in overturning is sufficient
Factor of safty in Sliding is sufficient
2 Check for Stability at Bed Level (When the wier is just submerged)

Top width, a = 3.000 m


Bottom width, b = 4.500 m
Height of checkdam, Ht = 3.500 m
Density of Concrete, ɤc = 24.00 KN/m³
Density of Water, ɤw = 10.00 KN/m³
Depth of flow over weir, Htw = 0.662 m

Htw = 0.662 4 a=3 Crest Level

5
Htw = 0.662
Ht = 3.5 1
3
2 5
WP Bed Level
O WP
b = 4.5

V - Vertical Force H - Horz Force Lever Arm Mo MR


Sl.No Ref Particulars
KN KN m KN.m KN.m
1 1 Body wall 147.000 3.000 0.000 441.000
2 2 Body wall 36.750 1.000 0.000 36.750
3 3 Water Pr 23.170 1.750 40.548 0.000
4 3 Water Pr 61.250 1.167 71.458 0.000
5 3 Water Pr 2.191 3.721 8.153 0.000
6 4 Wt. of Water 9.930 3.500 0.000 34.755
7 5 Wt. of Water 26.250 0.500 0.000 13.125
219.930 86.611 120.159 525.630

Resultant Force acts at distance of (ẍ from O) (MR - MO) / V = 1.844 m


Eccentricity (e) |b/2- ẍ| = 0.406 m
Maximum Bending Stress Pmax V/b (1+6e/b) = 75.33 KN/m2
Minimum Bending Stress Pmin V/b (1-6e/b) = 22.417 KN/m2
2
Permissible Compressive stress 7000 KN/m
Permissible Tension stress -530 KN/m2
Factor of Safty (Overturning) FSO MR/MO = 4.374 (must be >2.0)
Factor of Safty (Sliding) FSS 0.6V/H = 1.524 (must be >1.5)
As Maximum Bending Stress is within permissible limit, it is Safe
Tension within Limits, Hence Safe
Factor of safty in overturning is sufficient
Factor of safty in Sliding is sufficient
3 Check for Stability at Foundation Level ( When water is upto crest level and No tail water)
Top width, a = 3.000 m
Bottom width, b = 4.500 m
Height of checkdam, Ht = 3.500 m
Density of Concrete, ɤc = 24.00 KN/m³
Density of Water, ɤw = 10.00 KN/m³
Density of Silt, ɤs = 21.000 KN/m³
Offset of Foundation, Ot = 0.600 m
Depth of Foundation, Df = 0.600 m
Rankies coeff. of Active Earth Pressure, Ka = 0.333
a=3
Crest Level

b + (2 x Ot) = 5.7
Ht = 3.5 7 1
Df = 0.6
Ot = 0.6
4 2 Ot = 0.6

6
5 Df = 0.6 3 O
b = 4.5
b + (2 x Ot) = 5.7

V - Vertical Force H - Horz Force Lever Arm Mo MR


Sl.No Ref Particulars
KN KN m KN.m KN.m
1 1 Body wall 252.000 3.600 0.000 907.200
2 2 Body wall 63.000 1.600 0.000 100.800
3 3 Foundation 82.080 2.850 0.000 233.928
4 4 Water Pr 61.250 1.767 108.208 0.000
5 5 Water Pr 21.000 0.300 6.300 0.000
6 6 Silt Pr 0.659 0.200 0.132 0.000
7 7 Water Pr 21.000 5.400 0.000 113.400
418.080 82.909 114.640 1355.328

Resultant Force acts at distance of (ẍ from O) (MR - MO) / V = 2.968 m


Eccentricity (e) |b/2- ẍ| = 0.718 m
2
Maximum Bending Stress Pmax V/b (1+6e/b) = 181.849 KN/m
2
Minimum Bending Stress Pmin V/b (1-6e/b) = 3.964 KN/m
Permissible Compressive stress 7000 KN/m2
Permissible Tension stress -530 KN/m2
Factor of Safty (Overturning) FSO MR/MO = 11.822 (must be >2.0)
Factor of Safty (Sliding) FSS 0.6V/H = 3.026 (must be >1.5)
As Maximum Bending Stress is within permissible limit, it is Safe
Tension within Limits, Hence Safe
Factor of safty in overturning is sufficient
Factor of safty in Sliding is sufficient