Customer +
APPLICATION FOR APPROVAL
PVC INSULATING TUBE
TYPE
CAT NO : DC-3, DC-6
DATE
REMARK
DAE CHANG ELECCOM CO., LTD
70, Seoicheon-ro 528beon~gil, Majang-myeon,
Icheon-si, Gyeonggi-do, Korea
TEL.82-31-637-9930 FAX.82-3
939SPECIFICATION
Issued
PVC Insulating Tubing Date _|Z00!- 05. 01
‘Type Cat No: DC-3 . DC-6 Revised
" . 2019. 03. 25)
Date
1. Scope of Application
This specifications is applied to UL standard subject 224 for PVC Insulating Tubing.
2. File No
UL : 120268
3. Rating
1) temperature + 1050
2). Voltage : 300V (DC-3 ). 600V (DC-6)
4, Structure and Dimension : refer to tab-O1 (attached)
5. Surface Marking
The distance between the ending and beginning of the marking shall not exceed
6 inches
8 Ye DC-3 (or DC-6) 300V (or 600V) 105°C VW-1 PVC TYPE
## Inch) ROHS P/F -DAE CHANG- )
packaging as per Roll
AWG No, Winding length
1 inch ~ 5/8 inch 50M
3/8 inch - 1/2 inch 100M
o-1
4
5-17
18 - 24 1.000M
7. Tag : Each coil shall be fixed UL Tag8. Features
Head Unit Requirement
tensile strength MPA Min 104
lunaged
2°" | Elongation Percent Min .100
tensile strength . Min 75
sued 8 Min %
Aged
of the result unaged -
Elongation Be) Min 65
Deformation Percent Min .35
Dielectric strength No breakdown
, ; burning time max60s
Flame retardant (test specimen is ~
es flag burn : max25%
supported vertical position
Pt ' (vw-l)
Cold bend No cracks
Heat-resistance No breakdown
Copper stability Not corrosion
Longitudinal change Percent 10%
Insulating varnish test
No cracksStandard Size Tab‘01
Si Inside Dia Thickness (mm)
AWG NO (mm} 300V 3) G00V (DC-6)
wa 0540.1 034 = 0.45 0.43 — 0.55
2% 0,650.1 : :
20 0.36:0.04 7 7
18 1.07+0.05 7 7
17 1,190.06 7 7
16 1.34007 034 = 0.45 056 = 0.70
15 1.502008 7 7
4 1,680.08 7 7
13 1.93%0.10 7 7
12 2.16+0.11
in 2440.21 7 7
10 2,690.13 7 7
9 3,000.15 043 056 = 0.70
8 3.3840.17 7 7
7 3.76%0.19 7 7
6 % =
4 5.284026 7 7
3 5,940.30 7 7
2 6.68+0.33,
1 7.35+0.37,
0 8.3840.42 7 7
38 056 = 07 056 = 0.70
7/16 : :
V2 12,740.64 : :
58 15,9080 0.76 ~ 1.0 0.76 ~ 1.0
3/4 19.10.96 : :
The thickness per spec is admitted if it should exceed
the minimum thickness as specified by UL, but our management policy specifies
the maximum thickness for management's sake.