P.O.

Box 85652 ,RAK ,United Arab Emirates


RAKIA Free Zone, Al Jazeera, Al Hamra, RAK,U.A.E
Tel:+971(7)2445002 Fax:+971(6)5269096
Email: inf o @ac e -m e .c om

Cummins Power Generation Ltd. Date: 14th .March, 2015.


P.O.Box, 17636,
Jebel Ali Free Zone,
Dubai,
U.A.E.
Attn.: Mr. Harshal
Quote ref. #: ACE / CUM / Q922 C722/ 01
Your ref. #: e-mail, 12th , March, 2015.
SUBJECT: Offer For Packaging Of Cummins C700D5 Genset, In 20 Ft. Std Modified
Container, approx. 85 db (A) @ 1 mtr. In Free Field Conditions:
Dear Sir,
Thank you for the enquiry. We are pleased to submit our offer for the subject container.

PRICE PER UNIT: AED 49,900.00.

PRICE PER UNIT FOR SS 316 L FLEXIBLE BELLOW: AED 17,00.00


(6’’ BELLOW WITH ONE SIDE SS FLANGE)

Genset: Cummins C700D5.


Length: 6.058 mtr.
Width: 2.438 mtr.
Height: 2.591 mtr. Without muffler.
Our offer is based on the drawing no CPG-STD-DWG-ENC-001 REV-A which sent to us on above
mentioned mail date and as following:
Scope:
Packaging of std. modified, 20’ ISO container,
Enclosure:

 Modified 20’ STD ISO container.


Side / Roof panels:

 The panels shall be made with 50 mm thick inner lining of glass / rock wool of 48 Kg. /
CUM density, and covered with 0.7 mm thick perforated GI sheet.

Air Suction:

 The air suction shall be horizontal through chevron type louvers as per above mentioned
drawing no.
Air Discharge:

 The air discharge shall be horizontal through splitter type attenuators & 45 deg staright
louver as per above mentioned drawing no.

w w w . a c e - m e . c o m
Design & Manufacturing of EOT Cranes, Gantry Cranes, Jib Cranes, Special Purpose & Explosion Proof Cranes, Acoustic Enclosures for Gensets ,
Containerized Workshop, Office/Accommodation Modules , Acoustic Design Services, Operator cabins, Spreader/Lifting Beams,Onsite Room,
Acoustics Solutions, Critical Grade Muffler Solutions, UL/UN listed Double/Single-wall Storage Tanks,
Surface Preparation & Coating of Steel Structures
Doors:

 Enclosure shall be fixed with 2 Nos. of Single doors.


 Doors shall have panic release push button type locks.
 The doors shall have container type S.S hinges & door catchers.
 Rubber beading shall be provided on the door frames.
Internal lighting & Electricals:

 Enclosure shall be fitted with 3 no. florescent type 2 x 36 watt. IP 65, light fittings operated
on 250V AC, 50 Hz. The make shall be Crompton U.K or equivalent.
 Enclosure shall be fitted with 3 no. florescent type 8 watt. IP 65, light fittings operated on
250V AC, 50Hz with 2 hrs battery back-up. The make shall be Crompton U.K or equivalent.
 Enclosure shall be fitted with 2 no. bulk head lights and will be placed above each door.
 1 no industrial sockets, 16 A, 3 pin type shall be installed at the required locations.
 1 no. D.B Box (metal body) shall be installed. The make shall be ABB Germany or
equivalent.
 2 no. 2- way gang switches shall be provided. The make shall be Volex, U.K or equivalent.
 Earthling boss at opposite corners to be provided on the skid base for direct connection of
earthling cable.
 Cable cutout shall be provided for cable outlet.
 2 no. of emergency push button, with cover, shall be provided on each side of the enclosure.
Other Features:

 A special sealant shall be applied on the roof top cut-outs for roof sealing.
 Free issued Mufflers shall be fitted on top of the container (cylindrical muffler) or will be
mounted inside the enclosure with proper supports and rain cap (box muffler).
 SS flexible and pipe connections from the engine exhaust (inside the enclosure) to the
muffler shall be covered with jacket type heat insulation.
 MS Cheq. Plate shall be fixed on the floor and will be fully welded.
 Fuel in & out connections shall be brought to the edge of the container.
 Lube oil drain connection shall be brought to the edge of the container.
 Radiator drain connection shall be brought to the edge of the container.
 A cut-out shall be made on the roof top for access to radiator filling.
 Ladder shall be provided for access to the roof.
 Container CSC certificate shall be provided.
 The container floor shall be bunded for engine oil and coolant and sump.
Painting:

 The steel material shall be grit blasted to S.A 2½, and primer painted.
 As the container wall surface is zinc coated & pre-painted, it shall be painted with a special
acrylic based paint. The paint shall be sigma / equivalent.
 The paint thicknesses shall be approx 160-180 µ.
 The external & internal paint shade shall be RAL colour of your choice.
NOT INCLUDED:

 Batteries.
 Any type of gauges, sensors or detectors other than fire system.
 Any third party certification.
 Fan Motor control Panel.
 Cable for fan motor control panel.
 Genset painting.
 Battery acid.
 Engine oil.
 Radiator coolant.
 Load testing.
 Battery charger.
 Transportation.
 Vibration Isolators.
 Radiator piping.
 Any type of electrical panel other than Aux. DB
 Any sort of electrical wiring other than electrical lights, switches, sockets & push buttons.
 SS exhaust flexible bellows.
 Muffler(s).
 Battery connecting cables.
 Insulation jacket other than the muffler connecting pipe & flexible bellow.
Delivery: Ex- works, to be discussed.
Payment: 60 days from the date of invoice.
Validity of quote: 30 Days

We hope that our offer meets your requirement. In case you need any further information please do
contact us.
We assure you our best service, quality of work and cooperation at all times.
Thanking you,

Imran Mohammed.