PATROL™- USL acoustic and ultrasonic · COMPLETE PROTECTION OF Dual-technology detector both low-frequency sound and ultrasonic signals must be detector determines intrusion ALL TYPES OF GLASS, incorporates two physical successively sensed within through walls, doors and all WALLS, DOORS means for determining a pre-determined time period. COMBINED types of glass within protected · INNOVATIVE METHOD FOR intrusion: registering the ACOUSTIC & ULTRASONIC area, in response to their DETECTING ACOUSTIC low-frequency impact waves Figure 1 destruction. INTRUSION DETECTOR SIGNALS and registering the change in Wall Breakage Detection frequency of ultrasonic waves · DIGITAL SPECTRAL ANALYSIS PATROL-USL with anti-mask (Doppler Effect). DETECTS BREAKAGE OF SOUND AND ULTRASONIC OF WALLS, DOORS AND technology detects any of the FREQUENCIES 1. The low-frequency ALL TYPES OF GLASS ultrasonic sensors’ masking · DUAL ACOUSTIC & acoustic signal is emitted upon attempts. ULTRASONIC TECHNOLOGY impact of glass, wall or door. · TWO OPERATING MODES 2. The Doppler Effect occurs INSTRUCTION · SEPARATE ADJUSTMENT FOR when the frequency of MANUALS BOTH ULTRASONIC AND ultrasonic waves continuously LOW-FREQUENCY SOUND emitted by the detector and CHANNEL SENSITIVITY reflected from different moving · BUILT- IN ANTI-MASK SYSTEM objects changes. · HIGH RFI/EMI PROTECTION See Figures 1, 2.
· AUTOMATIC GAIN CONTROL -
ADAPTATION TO ENVIRONMENTAL CHANGES
1 2 3 4 5
Figure 2 For wiring, use the designated INSTALLATION DETECTOR
Glass Breakage Detection opening above the detector LIMITATIONS INSTALLATION OPTIONS terminal block. · Do not install the detector on 2. Connect the wires in unstable or vibrating surfaces. accordance with the scheme. · Do not install the detector + 12V - RELAY TAMPER close to curtains, blinds or other items that vibrate with air movement. · Do not install the detector close to air conditioners, air NOTE! blast sources or above heat Several detectors of this type sources. DETECTOR can be installed within the INSTALLATION · Do not install the detector protected area, at a distance of or route power wires and 1. Fix the detector vertically at least 3 meters from each alarm loops next to high on solid, flat wall surface. other. voltage cables. The installation height is 2 - 2.5 meters. · Do not install the detector near bells, sirens or electronic For corner installation, sounders within the premises use knockouts located on where sound-pressure level the sloping part of the exceeds 75dB. detector base. 6 7 8 9 10 DETECTOR TESTING 4. Test the ultrasonic channel · Stay for a while to 6. Simulate the alarm by DETECTOR OPERATING AND ADJUSTMENT operation. make sure the green LED gently tapping the glass/wall, MODES stops blinking, which means and at the same time, taking a 1. Remove the front cover. · First of all, make sure the detector ultrasonic channel step towards the detector. The detector PATROL-USL there are no humans or animals is configured correctly! If the The red alarm LED will light. has two operating modes: 2. Set Jumper J8 to “MODE 2” within the protected area, green LED keeps blinking, position. windows are closed; air 7. Set the desired operating check the premises without conditioners, fans and other mode using the J8 (MODE) 3. Connect the power – red interferences, as described possible sources of air flow are jumper. LED will blink. At the same above. If necessary, reduce time, keep the detector switched off. the excessive sensitivity of the To operate the detector field-of-view clear, until the · Walk into the detector detector with jumper J4 without light indication, LED stops blinking – the field-of-view. The green LED (Ultrasonic Sensitivity). remove the J9 (LED) jumper. MODE 1 anti-masking function will should actively respond to 5. Test the low-frequency 8. Replace the cover. For premises with stable then be correctly activated. your movement. If needed, sound channel operation. environmental conditions. Anti-mask startup (boot) increase the detector To do this, gently tap the period is 30 seconds. ultrasonic channel sensitivity glass, door or gypsum MODE 2 using J4 jumper wallboard with the palm of Ø If upon testing and (Ultrasonic Sensitivity). To provide extra security your hand. The yellow LED measures for banks, safes, detector adjusting, the red LED will light. vaults, jewelry stores, pawn keeps blinking, it means the Use the J2 (Microphone shops, museums and other anti-masking function is Sensitivity) jumper to adjust facilities that store valuables. activated. Turn off the detector the detector's low-frequency and then turn it back on. sound channel sensitivity.
11 12 13 14 15
PATROL-USL TECHNICAL Maximum protected volume: WARRANTY
DETECTION ZONE SPECIFICATIONS ………….........................200m³ GSN Electronic Company Ltd. Input voltage:............9 - 16Vdc warrants the product to be free Detection angle:…………..170° from defects in materials and TOP VIEW Current consumption Relay output:…………………... workmanship under condition …………NC; 60V; 120mA; 16Ω of observance of service In standby mode:……..43.2mА regulations and to be repaired In alarm mode:………..48.3mА Tamper output:……….NC; 10Ω or replaced under absence of mechanical damages for a Warm-up period:….……...2sec Operating temperature range:.. limited period of five years …………………–30ºC to +70ºC from the date of sale. Anti-mask startup (boot) period:………………...30±5sec Storage temperature range:….. ……..................–50ºC to +85ºC Alarm period:……...……...3sec RFI immunity:…………...30V/m Anti-mask alarm activation at a frequency range delay:………………….....35sec 10MHz - 2GHz J2 – Low-frequency sound channel sensitivity adjustment Ultrasonic channel operating EMI immunity:…………50000V J4 – Ultrasonic channel frequency:……………....40kHz Dimensions:………….……….... sensitivity adjustment Installation height:……2 - 2.5m ..........105mm x 50mm x 22mm J8 – Operating mode selection Weight:……………………..80g J9 – LED On/Off Detection range:……………7m P/N: USM0PATUSL_ENG_REV.A