PATROL-USR combined FEATURES ALGORITHM 3.

To activate the alarm, both


PATROL™- USR acoustic and ultrasonic
· COMPLETE PROTECTION OF Dual-technology detector
high-frequency and ultrasonic
signals must be successively
detector recognizes the sound ALL KNOWN GLASS TYPES incorporates two physical sensed within
caused by breakage of any INCLUDING INSULATED
means for determining glass a pre-determined time period.
COMBINED type of protected glass: plate, GLAZING AND GLASS BLOCKS
breakage: registering the
ACOUSTIC & ULTRASONIC wired, tempered, laminated,
· INNOVATIVE METHOD FOR high-frequency acoustic signal Glass Breakage Detection
patterned, multilayered¹,
GLASS BREAK DETECTOR DETECTING ACOUSTIC SIGNALS and registering the change in
sealed glazed windows¹
· DIGITAL SPECTRAL ANALYSIS frequency of ultrasonic signal
and glass blocks¹; all with a
OF SOUND AND ULTRASONIC (Doppler Effect).
DETECTS BREAKAGE OF thickness of 2.5 mm to 16 mm.
FREQUENCIES
VARIOUS TYPES 1. The high-frequency acoustic
¹ The detector registers
OF MULTILAYER GLASS · HIGHLY SELECTIVE signal occurs upon glass
breakage of multilayered SENSITIVITY OF HIGH-
glass that holds together when FREQUENCY SOUND CHANNEL breakage.
shattered, as well as sealed
glazed windows and glass · TWO OPERATING MODES 2. The Doppler Effect occurs
INSTRUCTION blocks if all glass layers are when the frequency of
MANUALS · SEPARATE ADJUSTMENT FOR
broken. BOTH ULTRASONIC AND
ultrasonic waves continuously
HIGH-FREQUENCY SOUND emitted by the detector and
PATROL-USR with anti-mask CHANNEL SENSITIVITY reflected from different moving
technology detects any of the objects changes.
· BUILT- IN ANTI- MASK SYSTEM
ultrasonic sensors' masking
attempts. · HIGH RFI/EMI PROTECTION See Figure Glass Breakage.

· AUTOMATIC GAIN
CONTROL ADAPTATION TO
ENVIRONMENTAL CHANGES

1 2 3 4 5

DETECTOR For wiring, use the designated INSTALLATION DETECTOR


INSTALLATION opening above the detector LIMITATIONS INSTALLATION OPTIONS
terminal block.
1. Fix the detector vertically · Do not install the detector on
on solid, flat wall surface. 2. Connect the wires in unstable or vibrating surfaces.
accordance with the scheme.
The installation height is · Do not install the detector
2 - 2.5 meters. close to curtains, blinds or
+ 12V - RELAY TAMPER
other items that vibrate with
For corner installation, use air movement.
knockouts located on the
sloping part of the detector · Do not install the detector
base. close to air conditioners, air
NOTE! blast sources or above heat
Several detectors of this type sources.
can be installed within the
protected area, at a distance · Do not install the detector
of at least 3 meters from each or route power wires and
other. alarm loops next to high
voltage cables.
· Do not install the detector
near bells, sirens or electronic
sounders within the premises
where sound-pressure level
exceeds 75dB.

6 7 8 9 10
DETECTOR TESTING 4. Test the ultrasonic channel · Stay for a while to make Use the potentiometer R11 DETECTOR OPERATING
AND ADJUSTMENT operation. sure the green LED stops (Microphone Sensitivity), MODES
blinking, which means the to adjust the high-frequency
· First of all, make sure there The detector PATROL-USR
1. Remove the front cover. detector ultrasonic channel sound channel sensitivity.
are no humans or animals has two operating modes:
is configured correctly!
2. Set jumper J8 to MODE 2 within the protected area, If the green LED keeps 6. Simulate the alarm by
position. windows are closed; air blinking, check the premises activating the glass breakage
conditioners, fans and other without interferences, as simulator, and at the same
3. Connect the power – red possible sources of air flow described above. time taking a step towards
LED will blink. At the same are switched off. If necessary, reduce the the detector. The red alarm
time, keep the detector excessive ultrasonic channel LED will light.
field-of-view clear until the · Walk into the detector sensitivity with the J4
7. Set the desired operating MODE 1
red LED stops blinking - the field-of-view. The green LED (Ultrasonic Sensitivity)
mode using the J8 (MODE) For premises with stable
anti-masking function will should actively respond to your jumper.
jumper. environmental conditions.
then be correctly activated. movement. If needed, increase
Anti-mask startup (boot) the detector ultrasonic channel 5. Test the high-frequency
period is 30 seconds. sensitivity using J4 (Ultrasonic sound channel operation. · To operate the detector MODE 2
Sensitivity) jumper. without light indication, remove To provide extra security
If upon testing and detector Use the glass break simulator the J9 (LED) jumper. measures for banks, safes,
adjusting, the red LED keeps to simulate the high-frequency vaults, jewelry stores, pawn
blinking, it means the anti- glass breakage signal. 8. Replace the cover. shops, museums and other
masking function is activated. The yellow LED will respond facilities that store valuables.
Turn off the detector and then to each simulator activation.
turn it back on.

11 12 13 14 15

PATROL-USR TECHNICAL Maximum protected volume: WARRANTY


DETECTION ZONE SPECIFICATIONS ………….........................200m³
GSN Electronic Company Ltd.
Input voltage:............9 - 16Vdc warrants the product to be free
Detection angle:…………..170°
from defects in materials and
TOP VIEW
Current consumption Relay output:………………….. workmanship under condition
…………NC; 60V; 120mA; 16Ω of observance of service
In standby mode:……..37.3mА regulations and to be repaired
In alarm mode:………..42.2mА Tamper output:……….NC; 10Ω or replaced under absence of
mechanical damages for a
Warm-up period:….……...2sec Operating temperature range:.. limited period of five years
…………………–30ºC to +70ºC from the date of sale.
Anti-mask startup (boot)
period:………………...30±5sec Storage temperature range:…..
…………….......–50ºC to +85ºC
Alarm period:……………..3sec
RFI immunity:…………...30V/m
Anti-mask alarm activation at a frequency range
delay:………………….....35sec 10MHz – 2GHz
J4 – Ultrasonic channel
sensitivity adjustment Ultrasonic channel operating EMI immunity:…………50000V
frequency:……………....40kHz
J8 – Operating mode selection Dimensions:………….………....
Installation height:……2 - 2.5m ..........105mm x 50mm x 22mm
J9 – LED On/Off
R11 – High-frequency sound Detection range:……………7m Weight:……………………...80g
channel sensitivity adjustment P/N: USM0PATUSR_ENG_REV.A