Sunteți pe pagina 1din 2

PATROL-803 FEATURES DETECTOR INSTALLATION INSTALLATION

®
PATROL - 803 The PATROL-803 • HI-TECH DESIGN Fix the detector vertically
LIMITATIONS
is a combination of PIR and on solid, flat wall surface. • Do not install the detector on
COMBINED acoustic glass break detector. • DUAL TECHNOLOGY The installation height is unstable or vibrating surfaces.
PIR & GLASS PIR & MICROPHONE
2 – 2.5 meters.
BREAK DETECTOR The PATROL-803 is a digital • Do not install the detector
passive infrared detector with • HIGH RFI & EMI IMMUNITY For corner or ceiling close to curtains, blinds or
INSTALLATION dual element pyrosensor, • DIGITAL PROGRAM installations, you can use other items that vibrate with
INSTRUCTIONS which provides the most ALGORITHM OF SIGNAL universal brackets – models: air movement.
efficient security of residential PROCESSING "UBL-1112" or "UBL-1115."
and industrial premises. (Additional purchase!) • Do not install the detector
• PULSE COUNTER 1 or 2 close to air conditioners, air
The PIR detector analyzes For corner installation, blast sources or above heat
the environment and detects • TEST MODE FOR TWO use knockouts located on the
ACOUSTIC CHANNELS sources.
the person's motion crossing sloping part of the detector
the infrared beam. • INDIVIDUAL PIR SENSITIVITY base. • Do not install the detector
ADJUSTMENT or route power wires and
The acoustic glass break For protecting several
alarm loops next to high
detector identifies the sounds • HIGH LIGHT IMMUNITY windows, mount the detector
voltage cables.
of glass impact and breakage. at optimal distance from them.
• HERMETICALLY SEALED If heavy blinds of curtains
Two independent optoelectronic PYROELECTRIC SENSOR cover the glass, locate the
relays of the PIR and glass break detector so the blinds will not
detectors, allow connecting the • LOW OPERATING
TEMPERATURE
block the sound.
detectors to two independent
zones in the control panel. • AUTOMATIC TEMPERATURE
COMPENSATION
1 2 3 4 5

TERMINAL BLOCK DETECTOR ADJUSTMENT 5. Pass in the field of view SELECTING COVERAGE
CONNECTION detector. The RED LED RANGE
1. Remove the front cover.
should actively respond to your
+ 12V TAMPER RELAY 1 RELAY 2

Connect the wires according 2. Select the required number Set the jumper W2 according
movement.
to the scheme. of pulses (1 or 2) using S2 J1 to the distance to the
6. If necessary, increase the protected glass.
+ 12V -
regulator.
TAMPER RELAY 1 RELAY 2 detector PIR sensitivity, C18
GLASS

ACOUSTIC 6m
SENSITIVITY

using R18 potentiometer

+
1 PULSE 2 PULSE S1 LED
D4
RANGE 9m
R17
2 2 “PIR Sensitivity”. ADJUSTMENT 12m
1 1 PIR W2
PATROL
SHOCK &
W3 GLASS TEST

Terminals “+12V-“ - for S2 S2 SENSITIVITY 803


OPERATING
MODE

PROTECTED GLASS TYPES


+

connection to the power supply PIR


SENSITIVITY
PIR
SENSITIVITY
PULSE GLASS TEST

2 W1
of the control unit. R18 1 Min. Max.
*Selectable pulse counter 1or 2 S2 ACOUSTIC
Glass Type
Thickness Thickness
Terminals “Tamper” - for provides users with the option PIR
RANGE
ADJUSTMENT
Plate 2 mm 14 mm
connection to a 24-hour LED INDICATION ON SENSITIVITY
6M

+
of optimizing detector sensitivity W2 9M Tempered 3 mm 10 mm
normally closed protective zone ALARM. R18
Patterned 3 mm 12 mm
to suit the environment, thus 12M

in the control unit. retaining reliable performance LED LED Laminated¹ 3.2 mm 14.3mm
Wired¹ 5 mm 6.4 mm
Terminals “Relay 1”- relay at all times. ON ON
OFF OFF Coated (Triplex)¹ 2.5 mm 8.4 mm
W1 – Jumper to select operating
output of the PIR detector. 3. Connect the power and W3 W3
and test modes. Sealed insulating¹ 3.2 mm 6.4 mm

Terminals “Relay 2”- relay wait for LED to stop flashing Jumper W3 will enable/disable
(warm-up time 60 sec). W2 – Acoustic range adjustment ¹The detection range of the
output of the glass break the alarm LED. acoustic glass break detector
S2 – Pulse counter regulator
detector. 4. Replace the cover. If W3 is ON – LED will operate is reduced up to 10 meters for
R17 – Glass sensitivity regulator the following glass types:
on alarm.
If W3 OFF – LED will R18 – PIR sensitivity regulator Laminated, Wired, Coated
not operate on alarm. S1 – Tamper button (Triplex), Sealed Insulating.

6 7 8 9 10
GLASS BREAK TEST SHOCK & GLASS BREAK WIDE ANGLE LENS. VERTICAL BARRIER LENS LONG RANGE LENS
(ADJUSTMENT) TEST
TOP VIEW
1. Set the jumper W1 to the 1. Set the jumper W1 to
“GLASS TEST “position. "SHOCK & GLASS TEST" 10m
(33ft)
position.

1m 
SHOCK & GLASS

12.5m
TEST

(41ft)
OPERATING SHOCK & GLASS
MODE TEST
OPERATING 5m
GLASS TEST
(16ft)
W1 MODE
GLASS TEST
The PIR detector is off; W1

The RELAY 1 and RELAY 2 The PIR detector is off;


are opened. 0 125° 
The RELAY 1 is opened.
2. Replace the cover. The RELAY 2 is closed.
3. Use glass break simulator to 2. Replace the cover.
5m

(2.6ft) (5.3ft) (11ft)


0.8m 1.6m 3.4m
(16ft)

SIDE VIEW
simulate the high frequency

TOP VIEW
signal of the glass breakage. 3. Tap gently the protected
The red LED will flash with glass and activate the glass
break simulator at the same
10m
each simulator activation. (33ft)

time. The relay output of


4. Use the trimmer R17 marked

0.9m

0.9m
(3ft)

(3ft)

2.4m
(8ft)
the glass break detector

0
“GLASS SENSITIVITY” to adjust SIDE VIEW
will open for 3 sec.
in detector with more sensitivity. 2.3m
The red LED will be ON. (7.5ft)
GLASS
SENSITIVITY 4. After testing, set the jumper
+

0m 1.6m 3.8m 7m 10.7m 15.6m


W1 to the “OPERATING (0ft) (5.5ft) (12.5ft) (23ft) (35ft) (51ft)
R17 MODE” position. *ADDITIONAL PURCHASE *ADDITIONAL PURCHASE

11 12 13 14 15

UNIVERSAL BRACKET SUNSHIELD FILTER TECHNICAL Light immunity without sunshield WARRANTY
MODELS: SPECIFICATIONS filter:………....no less than 6500lux
GSN Electronic Company Ltd.
“UBL-1112”, “UBL-1115”. Light immunity with sunshield
Input voltage…………….8.5 – 16V warrants the product to be free
filter:………………..more 30000lux from defects in materials and
Current consumption:
Operating temperature workmanship under condition
In standby mode: …………17.7mA
In alarm mode:………………19mА range:……………….– 30°C +60°C of observance of service
regulations and to be repaired
Warm up period:…..………...60sec Storage temperature
or replaced under absence of
range:....................– 50°C – +80°C
PIR detection range:..15.6m x 125º
mechanical damages for a
Sunshield filter for extra RFI immunity: 30V/м limited period of five years
protection of pyroelectric PIR detection speed at a frequency range 30MHz-1GHz from the date of sale.
sensor of detector from range:…………………0.3 – 3m/sec
EMI immunity……………..50,000V
sunlight and car headlights. Glass break detection
range:……….……........12m x 160º Dimensions:………………………... 7 ATARA ST.
……………54mm x 33mm x 99mm NAZARETH ILLIT 17802
Relay output:………………………. P.O.BOX 17719
……….........NC; 60V; 100mA; 16Ω Weight:…………….…………...82gr.
ISRAEL
Tamper output:…………...NC; 10Ω TEL: + (972) 4 6467152
FAX: + (972) 4 6562414
Alarm period:….......................3sec
WWW.GSNCOMPANY.COM
Reset time:………………..5 ± 1sec
6 7 8 9 10
GSN@GSNCOMPANY.COM
Pulse counter:………….........1 or 2
Installation height:……...2.0 – 2.5m
OC03

*ADDITIONAL PURCHASE *ADDITIONAL PURCHASE P/N: USM0EPAT803_REV.A

16 17 18 19 20