Sunteți pe pagina 1din 2

PATROL-105PET FEATURES DETECTOR INSTALLATION

®
PATROL - 105PET The professional combined • HI-TECH DESIGN
INSTALLATION LIMITATIONS

COMBINED PIR & MW


passive infrared and Fix the detector vertically • Do not install the detector on
microwave detector with dual • HIGH RFI & EMI IMMUNITY on solid, flat wall surface. unstable or vibrating surfaces.
DETECTOR WITH
element pyrosensor, which • DIGITAL PROGRAM The installation height is
ANTI-MASK TECHNOLOGY • Do not install the detector
provides the most efficient ALGORITHM OF SIGNAL 2 – 2.5 meters.
AND PET IMMUNITY close to curtains, blinds or
security of residential and PROCESSING
UP TO 25KG For corner or ceiling other items that vibrate with
industrial premises.
INSTALLATION • DUAL TECHNOLOGY PIR & MW installations, you can use air movement.
INSTRUCTIONS PATROL-105PET with dual universal brackets – models:
technology PIR & MW provides • BUILT-IN SHOCK SENSOR "UBL-1112" or "UBL-1115." • Do not install the detector
stable detection while virtually (Additional purchase!) close to air conditioners, air
• ANTI-MASK PROTECTION blast sources or above heat
eliminating false alarms and
For corner installation, sources.
costly service calls. • IMMUNE TO PETS UP TO 25KG use knockouts located on the
PATROL-105PET with • DOPPLER PULSE-COUNT sloping part of the detector • Do not install the detector
anti-mask technology, to SELECTION (1-5) base. or route power wires and
detect all types of masking alarm loops next to high
• HIGH LIGHT IMMUNITY For protecting several
attempts. voltage cables.
windows, mount the detector
PATROL-105PET includes a • INDIVIDUAL PIR AND MW at optimal distance from them.
SENSITIVITY ADJUSTMENT If heavy blinds of curtains
shock sensor to detect
external attack. • LOW OPERATING cover the glass, locate the
TEMPERATURE detector so the blinds will not
PATROL-105PET provides pet block the sound.
immune detection up to 25kg. • AUTOMATIC TEMPERATURE
COMPENSATION
1 2 3 4 5

PIR ADJUSTMENT MW ADJUSTMENT CHANGING RELAY 1. TERMINAL BLOCK


1. Remove the front cover. SWITCH CONNECTIONS
1. Remove the front cover. 2. MW ANTENNA
2. Set Jumper W1 to the 1. Disconnect the power. 1
"MW TEST" position, RELAY 1 3. W2 - ON/OFF LED JUMPER
2. Connect the power and + 12V TAMPER RELAY 1 RELAY 2

is open. 2. Set Jumper W4 to "OFF"


wait for LED to stop flashing 4. W1 - JUMPER TO SELECT
3. Replace the cover. position. OPERATING AND TEST MODES
(warm-up time 60 sec).
4. Use the "MW SENSITIVITY" 3. Restore power. 5. W4 - JUMPER TO SELECT 2
potentiometer to adjust the MW
3. Set Jumper W1 to the NC/NO
sensitivity, moving within the PULSE-COUNTING METHOD
"PIR TEST" position, protected area. The green LED 6. W5 - ON/OFF SHOCK SENSOR
RELAY 1 is open. should flash with each step. Selectable pulse count 1, 2, 3, 4, JUMPER 13
OPERATION MODE or 5 provides users with the 12 3
4. Replace the cover. option of optimizing detector 7. W3 - PULSE PROGRAMMING
1. Set Jumper W1 to "WORK" 11

+
W2 MW

JUMPER
S1 R53 TEST

position. sensitivity to suit the


LEDs
WORK
PIR
4

W4
5
NO

5. Walk into the detector field- 2. Set regulator W6 according environment, thus retaining 8. ANTI-MASK SENSITIVITY MW S2
NC
TEST
W1

10

W3
SENSITIVITY

of-view. The red LED should to animal weight. reliable performance at all times. ADJUSTMENT 25KG PATROL
PROG.
PULSE
SHOCK
SENSOR
ON/OFF 6
To adjust pulse count for 105 W5

flash with each step. Use the 3. Close the cover – LED will
15KG
7
specific operating environments: 9. PIR SENSITIVITY ADJUSTMENT PET
W6

"PIR SENSITIVITY" blink. At the same time, depart IMMUNITY

PIR ANTIMASK

from detector for correct the 1. Remove Jumper W3. 10. W6 - ANIMAL WEIGHT 9
SENSITIVITY SENSITIVITY
8
potentiometer to adjust the

+
setting of system antimasking REGULATOR
PIR sensitivity, moving within The green LED blinks
until the LED stops blinking. indicating that pulse counting 11. MW CHANNEL SENSITIVITY
R70 R50

the protected area. The anti-mask function will has begun. ADJUSTMENT
then be activated correctly.
Use the “ANTIMASK 2. Replace Jumper W3 during 12. S1 - TAMPER BUTTON
SENSITIVITY” potentiometer pause between LED blinking.
13. S2 - SHOCK SENSOR
to adjust anti-mask sensitivity.
6 7 8 9 10
SHOCK SENSOR TERMINAL BLOCK WIDE ANGLE LENS LONG RANGE LENS VERTICAL BARRIER LENS
CONNECTION
PATROL-105PET includes a TOP VIEW - MW DETECTION
ZONE
shock sensor that detects + 12V - TAMPER RELAY 1 RELAY 2
external attack. Any physical 10m
impact or attempt to separate

1m 
(33ft)

12.5m
(41ft)
the detector from the wall will
trigger an alarm signal to the Terminals “+12V-“ – for 5m
control connection to the power (16ft)
panel through the terminal supply of the control unit.
«TAMPER».
Jumper W5 enables/disables Terminals “Tamper” – 0 120° 
the shock sensor. for connection to a 24-hour
• Jumper W5 On - Shock normally closed protective

(2.6ft) (5.3ft) (11ft)


0.8m 1.6m 3.4m
zone in the control unit.

SIDE VIEW
5m

TOP VIEW
Sensor activated. (16ft)

• Jumper W5 OFF - Shock Terminals “Relay 1” –


Sensor disabled. PIR detector relay output. 10m
(33ft)

0.9m

0.9m
(3ft)

(3ft)

2.4m
(8ft)
SIDE VIEW

0
SHOCK Terminals “Relay 2”–
S2 2.3m
SENSOR
anti-mask relay output. (7.5ft)

ON/OFF SHOCK
0m 1.6m 3.8m 7m 10.7m 15.6m
* Detection range for Patrol-105PET
SENSOR JUMPER decreases up to 16 meters at using
W5 (0ft) (5.5ft) (12.5ft) (23ft) (35ft) (51ft)
“Long range lense”

*ADDITIONAL PURCHASE *ADDITIONAL PURCHASE

11 12 13 14 15

SUNSHIELD FILTER UNIVERSAL BRACKETS TECHNICAL Reset time:………………..5 ± 1sec WARRANTY


“UBL-1112”, “UBL-1115” SPECIFICATIONS PET mode:………………...15/25kg GSN Electronic Company Ltd.
Input voltage……………….9 – 16V Pulse counter:……...........1,2,3,4,5 warrants the product to be free
Current consumption: from defects in materials and
Installation height:……..2.0 – 2.5m
In standby mode: …………...83mA workmanship under condition
In alarm mode:……………..125mА Light immunity without sunshield of observance of service
filter:………...no less than 6500 lux regulations and to be repaired
Microwave frequency:..10.525GHz
Light immunity with sunshield or replaced under absence of
Anti-mask startup (boot) filter:……………….more 30000 lux mechanical damages for a
Sunshield filter for extra period:……………..…….50 ± 5sec limited period of five years
Operating temperature
protection of detector Warm up period:…..………..60sec from the date of sale.
range:………..………–30°C +60°C
pyroelectric sensor from
sunlight and car headlights. Detection range:…....15.6m x 120º Storage temperature
Detection speed range:....................– 50°C – +80°C 7 ATARA ST.
range:………………..0.3 – 3 m/sec RFI immunity: 30V/м NAZARETH ILLIT 17802
Relay output:………………………. at a frequency range 30MHz-1GHz P.O.BOX 17719
………...NC/NO; 60V; 100mA; 16Ω EMI immunity……………..50,000V ISRAEL
TEL: + (972) 4 6467152
Tamper output:…........................... Dimensions:………………………...
……………..NC; 60V; 100mА; 16Ω FAX: + (972) 4 6562414
…………..54mm x 34mm x 120mm
WWW.GSNCOMPANY.COM
Anti-mask Relay output:………….. Weight:…………….………….115gr.
………..NC/NO; 60В; 100mА; 16Ω GSN@GSNCOMPANY.COM
Anti-mask alarm activation
delay:…………………......40-60sec
OC03

*ADDITIONAL PURCHASE *ADDITIONAL PURCHASE Alarm period:….......................3sec


P/N: USM0EPAT105PET_REV.A