Sunteți pe pagina 1din 2

FEATURES. DESCRIPTION.

PATROL – 801 • Digital mathematical algorithm The PATROL-801 is a combination of


of signal processing. PIR and acoustic glass break detectors.
PROFESSIONAL COMBINED • High light immunity – no less The PIR detector analyzes the
than 10000 Lux. environment and detects the person's
DIGITAL PIR & GLASS motion crossing the infrared beam.
BREAK DETECTOR • High RFI & EMI immunity
The acoustic glass break detector
• Two optoelectronic switch relays identifies the sounds of glass impact
INSTALLATION for glass break and PIR detectors. and breakage.
INSTRUCTIONS • Test mode for two acoustic channels. Due to unique program for processing
incoming signals from PIR and
• Self diagnostics – the GLASS BREAK detectors the
microcontroller controls the PATROL-801 enables an exceptionally
OC03 detector’s basic circuits. reliable detection and stable "false
• Hermetically insulated pyrosensor. alarms free" operation in extremely
www.gsncompany.com harsh environments.
• Automatic pulse counter.
Two independent optoelectronic relays
• Automatic temperature allow the detector to be connected to two
compensation. independent zones in the control panel.

ALGORITHM. For creating an alarm, both a PROTECTED GLASS


low-frequency sound of the glass TYPES.
Unique algorithm is based on recognition impact and a high-frequency glass
of sequence of low-frequency and breakage sound must be registered Glass Min. Max.
high-frequency signals of framed pane within a predetermined time frame. type Thickness Thickness
glass breakage. Low-frequency signal Plate 2 mm 10 mm
is emitted upon the impact of glass. Since both detector channels must Tempered 3 mm 8.4 mm
High-frequency signal occurs upon the Patterned 3 mm 10 mm
register the actual glass breakage,
glass breakage. Laminated ¹ 3.2 mm 14.3 mm
false alarms are practically excluded. Wired 5 mm 6.4 mm
HIGH FREQUENCY LOW FREQUENCY Coated ²
The program of microcontroller, 2.5 mm 8.4 mm
SIGNAL SIGNAL (Triplex)
based on the mathematical algorithm, Sealed
analyzes signals and detects only the 3.2 mm 6.4 mm
Insulating ¹
actual breakage of all standard framed
glass types. ¹ Laminated and sealed insulating
glass types are protected only
if both glass plates are broken.

² For glass coated with plastic film


on the inner surface, effective range
is reduced to 6m.

SELECTING MOUNTING PIR SENSITIVITY ADJUSTMENT. TERMINAL BLOCK CONNECTION.


LOCATION. Set the jumper to the “HIGH” position + 12V - TAMPER RELAY 1 RELAY 2
Choose a location most likely to for premises with stable environment.
intercept an intruder.
The recommended installation height PIR
to gain maximum protection zone Terminals “+12V-“ – for connection
SENSITIVITY to the power supply of the control unit.
is 2.1 - 2.3 meters.
For protecting several windows mount HIGH Terminals “Tamper” – for connection
the detector at optimal distance from LOW to a 24-hour normally closed protective
them. If heavy blinds of curtains cover zone in the control unit.
the glass, locate the detector so the Terminals “Relay 1” – relay output
blinds will not block the sound. Set the jumper to the "LOW" position of the PIR detector.
ATTENTION! for locations with unstable environment - Terminals “Relay 2” – relay output
thermal or other streams of air, vibration, of the glass break detector.
Avoid the following locations:
etc.
- Near sources of loud noises or AUTOMATIC PULSE COUNTER.
vibrations (heating/air conditioning The PATROL-801PET automatically
units, bells, fans, compressors, etc.) selects and counts incoming pulses,
- On the same wall as protected glass. according to the strength of the signals
coming to the detector.
SELECTING GLASS TYPE GLASS BREAK TEST. SHOCK & GLASS BREAK TEST.
AND COVERAGE RANGE. 1. Set the jumper W3 to
ATTENTION!
Set the jumper W1 according to the "SHOCK & GLASS TEST" position.
Testing should be conducted when
distance to the protected glass. the front cover of the detector is closed. The PIR detector is off; the RELAY 1
is opened, the RELAY 2 is closed.
Set the jumper W2 according to the 1. Set jumper W3 to “GLASS TEST”
protected glass type (see the figure). position. The PIR detector is off; the 2. Replace the cover.
RELAY 1 and RELAY 2 are opened. 3. Tap gently the protected glass and
PL - PLATE activate the glass break simulator at
W2 2. Replace the cover.
TM*- TEMPERED the same time.
PL 3. Use glass break simulator to simulate
- PATTERNED
The red LED will be ON for 3 sec,
LW - LAMINATED TM the high frequency signal of the glass
the RELAY 2 will open.
- WIRED GLASS breakage. The red LED will flash with
- COATED TYPE LW each simulator activation.
(TRIPLEX) ATTENTION!
- SEALED INSULATING 12M W3
After testing, set the jumper W3
RANGE GLASS TEST to “OPERATING MODE” position.
9M
ADJUSTMENT OPERATING MODE The PIR and Glass Break detectors
6M are operating; the RELAY 1 and
SHOCK & GLASS TEST
TM*position – for most glass types. W1 RELAY 2 are closed.

WIDE ANGLE LENS. CURTAIN LENS.


TOP VIEW
o
19.4
10m TOP VIEW
+ 12V TAMPER RELAY 1 RELAY 2 (33ft)

0 5.6
5m
* AUTOMATIC
PULSES W2 (16ft)
LED PL
ON o
TM
GLASS 0 110
OFF TYPE LW

PATROL 801 12M SIDE VIEW


5m
RANGE
ADJUSTMENT
9M (16ft) 7m
PASSIVE
6M 2.1m 18 (23ft)
INFRARED W1 (6.8ft)
& 10m 44

GLASS BREAK (33ft)


DETECTOR PIR o
W3 SENSITIVITY
19.4
GLASS TEST
HIGH SIDE VIEW 15m
OPERATING MODE LOW (49ft)
SHOCK & GLASS TEST 2.1m
GSN ELECTRONIC COMPANY LTD. CS (6.8ft)

1.7m 4.6m 7.7m 15.3m


(6ft) (15ft) (25ft) (50ft)

TECHNICAL SPECIFICATIONS. PIR detection


WARRANTY.
Detection speed range:...0.3 – 3.0m/sec range:..……………………….15m x 110º GSN Electronic Company Ltd.
Power input:……..………...8.5 – 16VDC Glass break detection warrants the product to be free from
defects in materials and workmanship
range:……….……................12m x 160º
Current consumption under condition of observance of
in stand-by mode:……………….18.4mA Light immunity no less than:……………. service regulations and to be repaired
………………………………..10000 LUX or replaced under absence of
In alarm mode
mechanical damages for a limited
with LED on:……………….….…19.1mA Operating temperature
period of five years from the
In alarm mode range:……………………– 30°C + 50°C date of sale.
with LED off:……………………. 14.4mA Storage temperature
Pulse mode:…………………...automatic range:……………………– 40°C + 80°C
Alarm period:..……………...………3 sec RFI immunity:……………….30 V/m at a
frequency range 10MHz-1000MHz
Warm up period:……………...40 ± 2 sec
EMI immunity:…………………..50 000V
Reset time:……………………..5 ± 1 sec
Dimensions:………………93x66x46mm
Relay output:……..NC; 60V;120mA;16Ω
Weight:…………………………...….97gr.
P/N: USM0E801 REV.B PRINTED IN ISRAEL