Sunteți pe pagina 1din 2

FEATURES. DESCRIPTION.

PATROL – 801PET
• Immune to pets up to 30kg The PATROL-801PET is immune
to pets of up to 30kg and 1m height.
PROFESSIONAL COMBINED • Digital mathematical algorithm
DIGITAL PIR & GLASS The PATROL-801PET is a combination
of signal processing
of PIR and acoustic glass break
BREAK DETECTOR detectors.
• High light immunity – no less
WITH PET IMMUNITY The PIR detector analyzes the
than 10000 Lux
environment and detects the person's
INSTALLATION • High RFI & EMI immunity motion crossing the infrared beam.
INSTRUCTIONS The acoustic glass break detector
• Two optoelectronic switch relays
for glass break and PIR detectors identifies the sounds of glass impact
and breakage.
• Test mode for two acoustic channels Due to unique program for processing
OC03
incoming signals from PIR and
• Hermetically insulated PYRO sensor GLASS BREAK detectors the
www.gsncompany.com PATROL-801PET enables an
• Automatic temperature compensation exceptionally reliable detection and
• Pulse counter. stable "false alarms free" operation in
extremely harsh environments.

ALGORITHM. For creating an alarm, both a PROTECTED GLASS TYPES.


low-frequency sound of the glass
Unique algorithm is based on recognition impact and a high-frequency glass Glass Min. Max.
of sequence of low-frequency and breakage sound must be registered type Thickness Thickness
high-frequency signals of framed pane Plate 2 mm 10 mm
within a predetermined time frame.
glass breakage. Low-frequency signal Tempered 3 mm 8.4 mm
is emitted upon the impact of glass. Patterned 3 mm 10 mm
Since both detector channels must Laminated ¹ 3.2 mm 14.3 mm
High-frequency signal occurs upon the register the actual glass breakage,
glass breakage. Wired 5 mm 6.4 mm
false alarms are practically excluded. Coated ²
2.5 mm 8.4 mm
HIGH FREQUENCY LOW FREQUENCY (Triplex)
SIGNAL SIGNAL The program of microcontroller, Sealed
3.2 mm 6.4 mm
based on the mathematical algorithm, Insulating ¹
analyzes signals and detects only the
actual breakage of all standard framed ¹ Laminated and sealed insulating
glass types. glass types are protected only
if both glass plates are broken.

² For glass coated with plastic film


on the inner surface, effective range
is reduced to 6m.

SELECTING MOUNTING PET IMMUNITY SETTING. PULSE COUNTER.


LOCATION. Set the switch S2 according to Set the jumper W5 to the "1P" position
Choose a location most likely to the animal weight. for premises with stable environment.
intercept an intruder.
The recommended installation height Set the jumper W5 to the "2P" position
to gain maximum protection zone for locations with harsh environment.
is 2.1 - 2.3 meters.
For protecting several windows mount 10KG
the detector at optimal distance from 20KG
them. If heavy blinds of curtains cover 30KG 2P
the glass, locate the detector so the
1P
blinds will not block the sound.
S2
ATTENTION! W5

Avoid the following locations:


- Near sources of loud noises or
vibrations (heating/air conditioning
units, bells, fans, compressors, etc.)
- On the same wall as protected glass.
TERMINAL BLOCK CONNECTION. SELECTING GLASS TYPE GLASS BREAK TEST.
AND COVERAGE RANGE.
+ 12V - TAMPER RELAY 1 RELAY 2 NOTE!
Set the jumper W1 according to the Testing should be conducted when
distance to the protected glass. the front cover of the detector is closed.
Set the jumper W2 according to the 1. Set jumper W3 to “GLASS TEST”
Terminals “+12V-“ – for connection protected glass type (see the figure). position. The PIR detector is off; the
to the power supply of the control unit. RELAY 1 and RELAY 2 are opened.
PL - PLATE
W2 2. Replace the cover.
Terminals “Tamper” – for connection TM*- TEMPERED
PL 3. Use glass break simulator to simulate
to a 24-hour normally closed protective - PATTERNED
zone in the control unit. LW - LAMINATED TM the high frequency signal of the glass
- WIRED GLASS breakage. The red LED will flash with
Terminals “Relay 1” – relay output - COATED TYPE LW each simulator activation.
(TRIPLEX)
of the PIR detector. W3
- SEALED INSULATING 12M
Terminals “Relay 2” – relay output RANGE GLASS TEST
9M
of the glass break detector. ADJUSTMENT
OPERATING MODE
6M
SHOCK & GLASS TEST
TM*position – for most glass types. W1

SHOCK & GLASS BREAK TEST. WIDE ANGLE LENS.


1. Set the jumper W3 to
15m Вид сверху
"SHOCK & GLASS TEST" position. (49ft)
The PIR detector is off; the RELAY 1 + 12V TAMPER RELAY 1 RELAY 2
10m
is opened, the RELAY 2 is closed. (33ft)

2. Replace the cover. W2 5m


(16ft)
LED PL
3. Tap gently the protected glass and ON
GLASS
TM o
activate the glass break simulator at OFF TYPE LW
0 90
the same time. PATROL 801PET 12m
5m
The red LED will be ON for 3 sec, RANGE
ADJUSTMENT
9m (16ft)

the RELAY 2 will open. W3


6m
W1 10m
GLASS TEST
(33ft)
OPERATING
MODE S2
NOTE! SHOCK & 15m
GLASS TEST 10KG (49ft)
After testing, set the jumper W3 20KG
2P PIR & GLASS Вид сбоку
to “OPERATING MODE” position. 1P BREAK DETECTOR
30KG
2.1m
The PIR and Glass Break detectors W5 GSN ELECTRONIC COMPANY LTD. CS
(6.8ft)

are operating; the RELAY 1 and 2m 4.5m 8.7m 15m 23m


RELAY 2 are closed. (6.5ft) (15ft) (29ft) (49ft) (75ft)

TECHNICAL SPECIFICATIONS. PIR detection WARRANTY.


range:..………………………...15m x 90º
Detection speed range:...0.3 – 3.0m/sec GSN Electronic Company Ltd.
Glass break detection warrants the product to be free from
Power input:……..………...8.5 – 16VDC
range:……….……................12m x 160º defects in materials and workmanship
Current consumption under condition of observance of
Light immunity no less than:……………. service regulations and to be repaired
in stand-by mode:……………….18.4mA
………………………………..10000 LUX or replaced under absence of
In alarm mode mechanical damages for a limited
Operating temperature
with LED on:……………….….…19.1mA
range:……………………– 30°C + 50°C period of five years from the
date of sale.
In alarm mode
Storage temperature
with LED off:……………………. 14.4mA
range:……………………– 40°C + 80°C
Pulse mode:…………………………...1,2
RFI immunity:………………..30V/m at a
PRINTED IN ISRAEL

Alarm period:..……………...………3 sec frequency range 10MHz-1000MHz


Warm up period:……………...40 ± 2 sec EMI immunity:…………………..50 000V
Reset time:……………………..5 ± 1 sec Dimensions:………………93x66x46mm
Relay output:……..NC; 60V;120mA;16Ω Weight:…………………………...….97gr.
P/N: USM0E801PET REV.A