Sunteți pe pagina 1din 9

Internal ceiling finishes

Taking off list

1 m2
13mm Thick "Emix" or the other approved and equivalent
skimcoating all in accordance with the manufacturers' instruction to
soffits of slabs, sides and soffits of beams not exceeding 3.50m
above ground level.

2 m2
600mm x 120mm 9.5mm thick "BORAL" gypsum ceiling boards;
set out symmetrically on exposed 50mm x 50mm aluminium T-joist
and spacer including 38mm x 12mm timber beading all around, all
as per Architect's instructions to 3.50m above ground level.

3 EXTRA OVER for forming 600mm x 600mm access panel Nos


complete with aluminium trimmer protection at perimeter of access
panel and opening.

4 Prepare and apply one coat of primer and tow coats of emulsion
paint, as described;

a) To skimcoated soffits of slab, sides and soffits of beam m2

b) To "BORAL" gypsum plaster board m2


Student Name: .................................. Drawing Ref No:............................
Taking-Off Paper
Student I.D No:................................... Page No: .......................................
(TUTORIAL)

Internal ceiling finishes 69.81 (b/f)

TV
Part A
13mm Thick "Emix" or the other Length: 1.38m
approved and equivalent Width: 1.43m
skimcoating all in accordance Part B
with the manufacturers' Length: 2.56m
instruction to soffits of slabs, Width: 3.59m
sides and soffits of beams not
exceeding 3.50m above ground
level.
& 1.38
1.43 1.97 Part A
2.56
Prepare and apply one coat of
3.59 9.19 Part B
primer and tow coats of emulsion
paint to skimcoated soffits of Store
slabs, sides and soffits of beam Part A
Guest room Length: 2.36m
Length: 4.72m Width: 1.80m
Width: 2.66m Part B
4.72 Length: 1.08m
2.66 12.56 Width: 1.38m
Dry kitchen 2.36
Length: 4.08m 1.80 4.25 Part A
Width: 2.21m 1.08
4.08 1.38 1.49 Part B
2.21 9.02 86.71
Dining
Part A
Length: 5.21m
Width: 1.48m
Part B
Length:4.08m
Width: 3.15
5.21
1.48 7.71 Part A
4.08
3.15 12.85 Part B
Living
Length: 5.21m
Width: 5.31m
5.21
5.31 27.67
69.81 m2 (c/f)
Student Name: .................................. Drawing Ref No:............................
Taking-Off Paper
Student I.D No:................................... Page No: .......................................
(TUTORIAL)
Student Name: .................................. Drawing Ref No:............................
Taking-Off Paper
Student I.D No:................................... Page No: .......................................
(TUTORIAL)

Internal ceiling finishes 28.86 (b/f)

Bedroom 3
Part A
600mm x 120mm 9.5mm thick Length: 1.27m
"BORAL" gypsum ceiling Width: 1.61m
boards; set out symmetrically on Part B
exposed 50mm x 50mm Length: 2.97m
aluminium T-joist and spacer Width: 2.58m
including 38mm x 12mm timber
beading all around, all as per
Architect's instructions to 3.50m
above ground level. 1.27
& 1.61 2.04 Part A
Prepare and apply one coat of
primer and tow coats of emulsion
paint to "BORAL" gypsum
plaster board. 2.97
2.58 7.66 Part B
Bath 6 Bedroom 2
Length: 1.97m Length: 4.68m
Width: 1.48m Width: 2.63m
1.97 4.68
1.48 2.92 2.63 12.31
Utiliy Bath 4
Length: 3.15m Length: 2.49m
Width: 2.07m Width: 1.46m
3.15 2.49
2.07 6.52 1.46 3.64
Wet kitchen Bedroom 4
Part A Part A
Length: 3.30m Length: 2.14m
Width: 2.07m Width: 0.97m
Part B Part B
Length: 2.45m Length: 3.51m
Width: 2.21m Width: 2.58m
3.30 2.14
2.07 6.83 Part A 0.97 2.08 Part A
2.45 3.51
2.21 5.41 Part B 2.58 9.06 Part B
Bath 5 Bath 2
Length: 2.36m Length: 2.39m
Width: 1.50m Width: 1.46m
2.36 2.39
1.50 3.54 1.46 3.49
Bath 3 Family & Stair
Length: 2.49m Length: 7.75m
Width: 1.46m Width: 4.39m
2.49 7.75
Student Name: .................................. Drawing Ref No:............................
Taking-Off Paper
Student I.D No:................................... Page No: .......................................
(TUTORIAL)

1.46 3.64 4.39 34.02


28.86 m2 (c/f) 103.16 m2 (c/f)
Student Name: .................................. Drawing Ref No:............................
Taking-Off Paper
Student I.D No:................................... Page No: .......................................
(TUTORIAL)

103.16 (b/f) EXTRA OVER for forming


Study 600mm x 600mm access panel
complete with aluminium
Length: 6.63m
trimmer protection at perimeter
Width: 2.34m of access panel and opening.
6.63
2.34 15.51 3 3
Master Bedroom
Part A
Length: 5.22m
Width: 3.12m
Part B
Length: 3.12m
Width: 0.44m
5.22
3.12 16.29 Part A
3.12
0.44 1.37 Part B
Bath
Length: 2.34m
Width: 3.41m
2.34
3.41 7.98
Ddt wall
Length: 2.34m
Width: 0.19m
2.34
0.19 0.44
143.87 m2
Student Name: .................................. Drawing Ref No:............................
Taking-Off Paper
Student I.D No:................................... Page No: .......................................
(TUTORIAL)
Student Name: .................................. Billing Paper Page No: .......................................
Student I.D No:................................... (TUTORIAL)

Item Descriptions Unit Qty Rate Amount

INTERNAL CEILING FINISHES

A M2 87
13mm Thick "Emix" or the other approved and
equivalent skimcoating all in accordance with the
manufacturers' instruction to soffits of slabs, sides and
soffits of beams not exceeding 3.50m above ground
level.

B M2 87
Prepare and apply one coat of primer and tow coats of
emulsion paint to skimcoated soffits of slabs, sides and
soffits of beam

C 600mm x 120mm 9.5mm thick "BORAL" gypsum M2 144


ceiling boards; set out symmetrically on exposed 50mm
x 50mm aluminium T-joist and spacer including 38mm
x 12mm timber beading all around, all as per Architect's
instructions to 3.50m above ground level.

D Prepare and apply one coat of primer and tow coats of M2 144
emulsion paint to "BORAL" gypsum plaster board.

E EXTRA OVER for forming 600mm x 600mm access NO 3


panel complete with aluminium trimmer protection at
perimeter of access panel and opening.
Student Name: .................................. Billing Paper Page No: .......................................
Student I.D No:................................... (TUTORIAL)

TOTAL COLLECTION :