Specified FAD 2160 Nm3/hr ( or 36 Nm3/min.

Therefore, at NTP conditions of 0°C, 1.033 kg/cm2A, Sea Level, Dry basis (0% RH), above capacity is required. However, Since site
conditions differ from NTP, Actual capacity of the compressor should depend on the following site conditions (As specified by
customer).

Ambient temperature 45 °C 318 °K


Relative Humidity (Design) 65 % (at above ambient temp)
Barometric Presure 0.99717 Kg/cm2A
(at 300 meter above mean sea level)
Applying Universal GAS law, P1 V1 P2 V2
=
T1 T2
Where, P1 = 1.033 Kg/cm2A
V1 = 2160 Nm3/hr
T1 = 0 °C (273K)
P2 = See Below
V2 = ?
T2 = 45 °C (313K)
For P2
Total Barometric Pressure of 0.99717 Kg/cm2 A at site consists of Air and Moisture partial pressures.
Applying Dalton's Law,

Total Pressure; PT = Pa+Pw


Where, PT = Total Pressure = 0. 0.99717 Kg/cm2 A
Pa = Partial vapour pr of dry air
Pw = Partial vapour pr of Moisture

Since Relative Humidity (RH) is less than 100% and not completely saturated (i.e 100%), the actual vapour pressure is =
% x Saturated vapour pressure of water at above Ambient temp.
Saturated vapour pr of water 0.09773 Kg/cm2A

Partial vapour pressure = 0.0635239 Kg/cm2A ( 65 % of saturated vapour pressure)

Therefore, Partial pressure of dry air; Pa = PT - P w 0.93365

Therefore, P2 = Pa = 0.93365 Kg/cm2A

Applying Universal GAS law, P1 V1 P2 V2


=
T1 T2
V2 = 2784 m3/hr
1638 cfm