Therefore, at NTP conditions of 0°C, 1.033 kg/cm2A, Sea Level, Dry basis (0% RH), above capacity is required. However, Since site
conditions differ from NTP, Actual capacity of the compressor should depend on the following site conditions (As specified by
customer).
Since Relative Humidity (RH) is less than 100% and not completely saturated (i.e 100%), the actual vapour pressure is =
% x Saturated vapour pressure of water at above Ambient temp.
Saturated vapour pr of water 0.09773 Kg/cm2A