Sunteți pe pagina 1din 9
User’s Manual Aw Ce Safety regulations Please read the safety regulations and operation guide carefully before operating. Please read all ofthe operational guide and safety reguiations nfs manual before operation . Improper operations ttithout complying with this manual guided could cause Gamage to the device, influence on measurement result Sr boally injury tothe user. As The instrument is not allowed to disassemble or repair Twany ways. Its forbidden to de any illegal modification or performance change for laser emitter. Please keep it Sof ofreach of children and avoid using by any irrelevant porsonn i Iti strictly prohibited to shoot eyes or other parts of body With the laser; it iz not allowed take the laser to shoot any Ddbjects: surface with strong reflecting i DS Due to electromagnetic radiation interference to other equipment and devices, please don't use the meter in th Diane or around medical equipment, don't use itn inflammable, explosive environment. A. Discarded battris or meter device shall not processed just ike household garbage, please handle them in line tith related law and regulations. 2S Any quality issues or any questions on the meter, please Contact loeal distributors or manufacturer in time, we are ready to offer solutions for you! Professional casts quality and good quality gets reputation por lay « Power Supply _ Lisa + Maximum) ———J pee = vLengi 6] BRRBBE Area, Volume and +} LECT BR ae 1 Sim = sum cry * BBBBBE: Pemendinory + Addition & Subtration/Sound «+ Reference Point! Unit Switch + Save + Tum offfRemove Conn ‘@ Battery Installation and Replacement + Discharge the battery door on the back of device, and place battery according to correct polarity, then cover the battery door. + Only 1.5 V AAA alkaline battery is applied to the meter. + If not used for a long time, please take out the battery to avoid battery corrosion to meter body. © Turn on/off the Instrument Under off status, press button 3), device and laser get starting simultaneously and stand by for measurement. Under on status, long press button © for 3 seconds to turn the device off. The device can also be shut off without any operation for 150 seconds. © Unit setting Long press button @ , reset current measurement unit, the default unit is: 0.000m There are 6 units for selection Units: Length ‘Areal Volume 0.000% 0.00007 0.000% 0.00m 0.00? 2.00m* 0.0m 0,007 0.008 0.008 0,008 0.008 Oem ‘200K 008 000196 000% 00% © Changing Reference Point Press @ key to change the reference point The device reference point by default is rear © Back Light On/Off The back light is set to turn on and off automaticly. The back light can be on for 15s while operating, and it will be shut off automaticly in 15s when there is no operation to the device. © Sound onloff Long press button ($9 to tum on or off the buzzer. CET This function can keep the precision of the device Instruction: Power off, Long press button), and then press 7). Release the button 2), then “CAL” and a figure shows on the screen. User can adjust the figure with button) @ according to the accuracy of the meter. Adjusting range: -9 to Smm, then, long press button G2) to save the calibration result JUTuLo ut ek © Single Distance Measuring: Tur on the laser beam by short press of the button €29 under measring mode, press the button 2 again for single measurement of length, then the measured results displayed in the major display area. ‘© Continuous Measuring: Long press button under measuring mode and enter into continuous measuring mode F--- ‘Maximum measuring result displays in auxiliary display area, present result displays in major display area. Short press botton @ or &} to exit continuous measuring mode. ‘@ Area Measurement: Press bution @ . ] shows on the screen One of the side of rectangle blinking on the. display, please follow the below instructions for area measuring Press © once for length Press €> again for width The device calculates and shows the result in the major display area, The resent measuring result of length is showed in the auxiliary display area.Press —_ , clear off the result and measuring again if necessary Press€) again to exit the mode. Volume Measurement Press button @ twice 1o enter volume measurement mode. A (will shows on the top of screen. Please follow the below instruction for volume measuring: Press 29 for Length Press @} again for Wiath Press 9 thirdly for height The device calculates and shows the result in the major display area The device calculates and shows the result in the major display area. Press €23, clear off the result and measuring again if necessary. Press again to exit the mode. © Pythagoras There are four Pythagoras modes in case that user gets hard to reach the target. 1. Calculate the second leg by measuring the hypotenuse and another leg. Short press @) three times to enter Pythagoras mode, the hypotenuse of “J blinking, Press «<>, measure the length of hypotenuse (a) Press <>, measure the length of one leg (b) Device calculates the length of another leg (x) 2. Calculate the hypotenuse by measuring the length of two legs. Shor press © four times, when one leg of 1 biinking, Press @®, measure the length of one leg (a) Press € , measure the length of another leg (b) Device calculates the length of hypotenuse (x) 4. Press @ five times till the one side of = blinking on the screen. Press@, measure the length of one side (a) Press), measure the length of the median line (by Press@, measure the length of another side (c) Device calculates the length of the leg in full line (x) 4, Press © six times till the hypotenuse of to get the summation result of these two areas which is showing in PICS al ass. o osges| i --- % a598. ©, «Bb6S-| «B3SBs oO ee aE 8358 a) * 0998 a 0156 =) Pict pice PICs 10 a Long press bution @ior 3s 10 record your Trem Specifications: measuring result under measuring mode. Tiaiance measurement — It can also record the result untier Area, Volume areas tO i and Pythagoras mode. All he calculating records “Cortiuous measure ves can be saved by the device ‘oMiment uncon urdoar at eon 7 oan © Read / Delete the Record: rea resuremen Toncion yee Short press bution ©), read the records by press Wale easement yes button 9 ©. short press | to delete recent Fagot poe cumode record and long press | to clear up all the sear ea records, Press <-> or @ to exit record mode. Rata er ve ‘aries vaio i= » 30 units War sora n> = a Fafomatebackight r You may get some warning information as below: Buttons/Keys sound = Taser el Tao Taser pe Bem. Miata fave Soon Fuscratealy ou oF ase 205 hos ne sotace wih charger “atari shaldown 7505 tr | sgatstoowean | Sigctice Une be teecas ene = Bate Working temperate Te-a0e =opace wih wer 12 | Signa stoo ston | Slee ern eles Serge hur Anas plate. Batley T5V "AA = Times or angle measurement tra [Lom tateryvatage | Change he power supp Bat a0 Too navrgsatow) 1105 The working Ie the device in the spectied am Tes0250m are and ensie at No: Use tage ate ras tbe meaner ange ia ews | Pahagoras Besoionuse bigger tien UJeyight or the target has poor rellecion propertes. ses | FM ror 2 Oa: '# The meter should not be stored in high temperature and strong humiglty environment for long time: if it is nol used very often, please take out the batter ‘and place the meter in the allocated polable bag and store in cool and dry place. Please keep the device surface cleaning, Wet soft ‘loth is applied to clean dust, bul erosion liquid ie never allowed to use for the meler maintenance. Laser output window and ils focus lens can be maintained according to maintenance procedures {for optical device Please check if the accessories are completed according to the below list NO. ttem Unit | QTY Note 1. [Laverastance meter] pe | 4 2 [eonersppy ans | ve | 2 9 [User's manval = [os 4 | Ponaoie vag m= [a 3 [and wap an 6 [inbox ee [4 7 [Retectr pe | 4 [agstevatabe ro 2 OEE: '# The meter should not be stored in high temperature and strong humiglty environment for long time: ifit is nol used very often, please take oul the batter ‘and place the meter in the allocated potable bag and store in cool and dry place. Please keep the device surface cleaning, Wet soft ‘loth is applied to clean dust, bul erosion liquid ie never allowed to use for the meler maintenance. Laser output window and ils focus lens can be maintained according to maintenance procedures {for optical device Please check if the accessories are completed according to the below list NO. ttem Unit | QTY Note 1. [Laverastance meter] pe | 4 2 [eowersuppy ans | ve | 2 3 [User's manval = [o 4 | Ponaoie ag me [a 3 [and wrap an 6 [inbox me [4 7 [Retectr pe | 4 [agstevalabe ro

S-ar putea să vă placă și