Dual Display Digital Pressure Sensor For Gas

713
DP-100 SERIES Ver.2
FIBER
■■General terms and conditions.............. F-3 ■■Selection guide.............................. P.699~
SENSORS Related Information ■■Glossary of terms........................ P.1563~ ■■General precautions...................... P.1566
LASER
SENSORS
■■Korea’s S-mark.............................. P.1602
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
Ver.2 Recognition
SENSORS
AREA
SENSORS
SAFETY LIGHT Certified
CURTAINS / [DP-101(A)/102(A) only]
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
* Passed the UL 991 Environment Test
SENSOR
OPTIONS * UL 61010C-1 compatible, Passed the UL 991
Environment Test based on SEMI S2-0200.
SIMPLE [Category applicable for semiconductor
WIRE-SAVING manufacturing: TWW2, Process Equipment]
UNITS [Applicable standards: UL 61010C-1]
WIRE-SAVING [Additional test / evaluation standards as per intended
SYSTEMS use: UL 991, SEMI S2-0200]

MEASUREMENT
SENSORS
STATIC panasonic.net/id/pidsx/global Digital Auto reference With analog
CONTROL output
DEVICES
LASER
MARKERS

PLC
Dual 3-color display makes operation easier!
HUMAN MACHINE
INTERFACES Achieved further efficiency with 4 upgrades, keeping the same operability
ENERGY
MANAGEMENT
SOLUTIONS UPGRADE 1
FA COMPONENTS
Superior visibility
MACHINE VISION Improved visibility in Digital Display
SYSTEMS

UV CURING Improvements to the digital display deliver a wide


SYSTEMS viewing angle along with increased clarity. The display
pressure range and set pressure range have also been
increased.

Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated Old DP-100 series New DP-100 series
Flow

UPGRADE 2
DP-0
DP-100 Long-distance transmission of analog output
DP-M Addition of analog current output capability to multifunctional models
Users can now select either voltage output or current output as analog output according to their application.
DP-100 SERIES Ver.2
Dual Display Digital Pressure Sensor
714

APPLICATIONS FIBER
SENSORS

Confirming suction of electronic component Confirming reference pressure Air-leak test for PET bottles LASER
SENSORS

PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
UPGRADE 3
SENSOR
OPTIONS
Reduced environmental impact 14 % lower SIMPLE
14 % lower power consumption (during normal operation) after update WIRE-SAVING
UNITS

Thanks to a redesign of its circuitry, power consumption WIRE-SAVING


SYSTEMS
of the low-power-consumption DP-100 series during
normal operation has been reduced by 14 %. The MEASUREMENT
SENSORS
display is shut off entirely during ECO / FULL mode
operation for power savings of up to 50 % compared Old DP-100 series New DP-100 series STATIC
CONTROL
to normal operation, and display brightness is lowered 840 mW (normal operation) 720 mW (normal operation) DEVICES
during ECO / STD mode operation for power savings of LASER
up to 30 % compared to normal operation. MARKERS
Up to 50 % lower
in ECO mode PLC

HUMAN MACHINE
INTERFACES
Normal operation ECO / FULL operation ENERGY
MANAGEMENT
720 mW 360 mW SOLUTIONS

FA COMPONENTS
UPGRADE 4
MACHINE VISION
Enhanced power circuitry SYSTEMS

Addition of a reverse polarity protection circuit to the transistor output circuit UV CURING
SYSTEMS
To prevent from breakage due to miswiring.

“Current value” and “threshold value” can be checked at the same time!
Selection
Dual display allows direct setting of threshold value Guide
Pressure/
Digital Display
Equipped with a 30 mm 1.181 in square compact-sized dual display. The Current Pressure/
current value and the threshold value can be checked at the same time, so value Head-separated
the threshold value can be set and checked smoothly without switching to Flow
another screen mode. ON/OFF operations still continue while the threshold
values are being set, so setting to the same sensitivity as dial control-type
sensors is possible. Key lock function is equipped as well. DP-0
DP-100
DP-M

Threshold
value
DP-100 SERIES Ver.2
715 Dual Display Digital Pressure Sensor

FIBER 3-color display (Red, Green, Orange) Readable digital display!


SENSORS

LASER The main display changes color in line with changes Alphanumeric indication in 12 segments is used. This
SENSORS in the status of output ON/OFF operation, and it also improved visual checking.
PHOTOELECTRIC
changes color while setting is in progress. The sensor
SENSORS status can therefore be understood easily, and operating
MICRO errors can be reduced.
PHOTOELECTRIC
SENSORS
OFF: Green (or Red) ON: Red (or Green) SET: Orange
AREA Main
SENSORS Display
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW During normal operation During setting
SENSORS
INDUCTIVE
PROXIMITY
SENSORS BASIC PERFORMANCE
PARTICULAR
USE SENSORS All models in the line-up are compound pressure types High performance accomplished Low pressure type
SENSOR
OPTIONS No sensor settings are required to switch between positive pressure and negative The low pressure type displays measurements in 0.1 kPa
SIMPLE pressure, so that the number of registered part numbers can be decreased. at a resolution of 1/2,000 and has a response time of 2.5
WIRE-SAVING ms (variable up to 5,000 ms), ±0.5 % F.S. temperature
UNITS <For low pressure> characteristics and ±0.1 % F.S. repeatability, giving it
WIRE-SAVING Ideal for applications such high performance.
SYSTEMS as suction.
No mis-operations due to <For high pressure>
MEASUREMENT vacuum breakdown occur. Ideal for applications such as
SENSORS
checking reference pressure.
Resolution: 1/2,000
–100 kPa 0 kPa 100 kPa
STATIC Can also be used for simple Response time: 2.5 ms
CONTROL For low suction.
DEVICES pressure DP-101□ Temperature characteristics: ±0.5 % F.S.
1 MPa
LASER Repeatability: ±0.1 % F.S.
MARKERS For high
pressure DP-102□
Displays measurements in 0.1 kPa
PLC

HUMAN MACHINE FUNCTIONS


INTERFACES
ENERGY Copy function reduces man-hours and human error
MANAGEMENT
SOLUTIONS
Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data
FA COMPONENTS to other sensors. If making the same settings for multiple sensors, this prevents setting errors among other sensors and in addition, when
machinery design are changed, there would be less change in work orders.
MACHINE VISION Details transmitted
SYSTEMS
Copying via wiring
UV CURING
SYSTEMS Master sensor Slave sensor Details received
Power supply
Detail
+V +V
s cop
0V 0V ied
Comparative output 1 Comparative output 1
Selection
Guide Comparative output 2 Comparative output 2
Pressure/
Digital Display Note: Settings cannot be copied from the new version (Ver. 2) to the old version.
Pressure/ However, settings can be copied from the old version to the new version (Ver. 2).
Head-separated
Flow

The sensor’s setting operation mode has a 3-level configuration to suit the frequency of use
DP-0
DP-100 The setting levels are clearly separated into “RUN mode”
for operation settings that are carried out daily, “MENU RUN mode
DP-M
SETTING mode” for basic settings, and “PRO mode” Settings such as threshold value
for special and detailed setting. These make setting adjustment and key lock operation
operations easy to understand and easy to carry out. can be carried out while the sensor
is operating.

MENU SETTING mode


Simple setting RUN mode
Basic settings such as output mode
setting and NO/NC switching can be
carried out.
MENU SETTING mode
PRO mode

Special and PRO mode High-level function settings such as


detailed setting
hysteresis adjustment and the copy
function can be carried out.
DP-100 SERIES Ver.2
Dual Display Digital Pressure Sensor
716

FUNCTIONS FIBER
SENSORS
Equipped with independent dual output and three output modes Standard type LASER
SENSORS
Equipped with two independent comparative outputs, 1 EASY mode
PHOTOELECTRIC
and separate sensing modes can be selected for each SENSORS
This mode is used for comparative output ON/OFF control.
of them. Since there are two comparative outputs, one MICRO
of the comparative outputs can even be used for alarm H (Hysteresis) PHOTOELECTRIC
SENSORS

Pressure
output. In addition, output, which is not being used, can P
AREA
be disabled. SENSORS
0
Vacuum breakdown can also be notified during suction applications! SAFETY LIGHT
ON CURTAINS /
Comparative output H: Fixed
OFF SAFETY COMPONENTS
Notes: 1) Hysteresis can be fixed to one of eight different levels. PRESSURE /
ON FLOW
Comparative output 1 2) “ ”appears in the sub display for comparative output 1, and
SENSORS
EASY mode Suction checking “ ” appears for comparative output 2.
OFF
INDUCTIVE
PROXIMITY
2 Hysteresis mode SENSORS
PARTICULAR
ON This mode is used for setting comparative output hysteresis USE SENSORS
Comparative output 2
EASY mode to the desired level and for carrying out ON/OFF control.
SENSOR
OFF OPTIONS
Vacuum breakdown checking
SIMPLE

Pressure
Hi
–100 kPa P-1 0 kPa P-2 WIRE-SAVING
H (Hysteresis) UNITS
Lo
0 WIRE-SAVING
Reference pressure alarm output is possible during reference pressure checking! ON SYSTEMS
Comparative output H: 1 digit or more
OFF
MEASUREMENT
Note: “ ” or “ ” appears in the sub display for comparative SENSORS
ON Reference
Comparative output 1 output 1, and “ ” or “ ” appears for comparative output 2. STATIC
pressure
Hysteresis mode checking CONTROL
OFF 3 Window comparator mode DEVICES
LASER
Alarm output
This mode is used for setting comparative output ON MARKERS
ON and OFF at pressures within the setting range.
Comparative output 2
PLC
EASY mode
OFF H (Hysteresis)
Pressure

Hi HUMAN MACHINE
H (Hysteresis) INTERFACES
0 kPa Lo-1 Hi-1 P-2 Lo
ENERGY
0 MANAGEMENT
ON SOLUTIONS
Comparative output H: Fixed
OFF
Notes: 1) Hysteresis can be fixed to one of eight different levels. FA COMPONENTS
2) “ ” or “ ” appears in the sub display for comparative
output 1, and “ ” or “ ” appears for comparative output 2. MACHINE VISION
SYSTEMS

UV CURING
SYSTEMS
Possible to switch over analog output and external input Multi-function type

Multi-function type that enables the selection of analog output (voltage/current) or external input (auto-reference/
remote zero-adjustment) is available. It complies a wide range of applications.
Selection
Guide
Pressure/
Comparative output Digital Display
Pressure/
Head-separated
Flow
is lighting.
Voltage Low pressure type: 1 to 5 V,
Analog output High pressure type: 0.6 to 5 V DP-0
Selection Current Low pressure type: 4 to 20 mA,
High pressure type: 2.4 to 20 mA DP-100
Multi-function type or
DP-M
External input Auto-reference/remote zero-adjust
DP-100 SERIES Ver.2
717 Dual Display Digital Pressure Sensor

FIBER FUNCTIONS
SENSORS

LASER Equipped with auto-reference/remote zero-adjustment functions. More precise pressure management is achieved with a minimum of effort Multi-function type
SENSORS
If the reference pressure of the device changes, two functions are selectable.
PHOTOELECTRIC
SENSORS
One is auto-reference function, which partially shift the comparative output
judgment level by the amount that the reference pressure shifts. The other
MICRO
PHOTOELECTRIC is remote zero-adjustment function, which can reset the display value to zero
SENSORS via external input. These functions are ideal for places where the reference
AREA pressure fluctuates wildly, or where fine settings are required.
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW With auto-reference function applied With remote zero-adjustment function applied
SENSORS
INDUCTIVE Comparative output: Window comparator mode Comparative output: Window comparator mode
PROXIMITY Hi-1…0, Lo-1…–5 Hi-1…0, Lo-1…–5
SENSORS Sets the absolute threshold level Sets the absolute threshold level
PARTICULAR Auto-reference input Remote zero-adjustment input
USE SENSORS The display remains at “30” and The display is forced to “0”, and only the
only the threshold level is changed. filling pressure drop range is displayed.
SENSOR
OPTIONS
30 30
SIMPLE 0
WIRE-SAVING 25 OK 25 –5 OK
UNITS
20 20
WIRE-SAVING Threshold level after applying Threshold level after applying
SYSTEMS auto-reference input remote zero-adjustment input
15 15
Threshold level before applying Threshold level before applying
MEASUREMENT auto-reference input remote zero-adjustment input
SENSORS
Trial 1 Trial 1
STATIC Pressure 0
CONTROL Pressure 0
DEVICES Displayed when remote zero-adjustment
–5 Auto-reference input value… –5 input is applied…
LASER Time Time
MARKERS When auto-reference input is applied, the reference pressure “30” When remote zero-adjustment input is applied, the reference
is added to the threshold level. If the reference pressure changes pressure is forced to “0”. If the reference pressure changes to
PLC
to “20” or “40”, the auto-reference input compensates for this “20” or “40”, the remote zero-adjustment input adjusts the
every time by changing the threshold level, so any variation in reference pressure to “0” every time the reference pressure
the filling pressure can be ignored. changes, so any variation in the filling pressure can be ignored.
HUMAN MACHINE
INTERFACES
ENERGY
Sub display can be customized Setting details can be recognized at a glance
MANAGEMENT
SOLUTIONS The sub display can be set to indicate any other desired The DP-100 setting details appear in the digital display.
FA COMPONENTS values or letters apart from the threshold value. This Because the settings are in numeric form that can be
eliminates the need for tasks such as affixing a label to easily understood, it is useful such as when receiving
MACHINE VISION the device to indicate the normal pressure value. technical support by telephone.
SYSTEMS 2nd digit: Setting status for
comparative output 2 3rd digit: Threshold value setting
UV CURING 1st digit: Setting status for 4th digit: Display color setting
SYSTEMS comparative output 1

Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
5th digit: Response time
setting 8th digit: ECO mode setting
6th digit: Display unit setting 7th digit: Display refresh rate setting
DP-0
DP-100 Peak hold and Bottom hold functions Energy-saving design! Equipped with an ECO mode
DP-M
The peak values and bottom values for fluctuating This mode lowers the display luminance to cut power
pressures can be displayed using the dual display. consumption by approximately 30 %. The displays can
also be turned off completely to achieve a power saving
of approximately 50 %.
Power consumption Power consumption
Approx. Approx.
Normal ECO-STD 30 % less ECO-FULL 50 % less

Blinks alternately

Current consumption for Current consumption for Current consumption for


24 V power supply: 30 mA or less 24 V power supply: 20 mA or less 24 V power supply: 15 mA or less
DP-100 SERIES Ver.2
Dual Display Digital Pressure Sensor
718

MOUNTING FIBER
SENSORS
Tight installation to panels is possible LASER
SENSORS
An exclusive mounting bracket that is suitable for 1 to 6
PHOTOELECTRIC
mm 0.039 to 0.236 in panel thickness is available. SENSORS
MICRO
Tight installation is possible Front protection PHOTOELECTRIC
Neat and cover available SENSORS
space MS-DP1-3
saving AREA
SENSORS
SAFETY LIGHT
A single mounting hole! CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
An exclusive mounting bracket (MS-DP1-1) that supports tight installation is available PARTICULAR
USE SENSORS
Space savings can also be achieved even when an L-shaped mounting bracket is used.
SENSOR
OPTIONS
• MS-DP1-1 • MS-DP1-5
Tight installation is possible SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS

MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS

Ceiling mounting Floor mounting Rear mounting Positioning bosses for easier PLC
mounting bracket installation
HUMAN MACHINE
INTERFACES
Types without connector attached ENERGY
Cable can be connected with one-touch cable are also available DP-10□-J MANAGEMENT
SOLUTIONS

Connector attached cable (2 m Commercially-available connectors can be used for FA COMPONENTS


6.562 ft), as an accessory, can be cable connections. Cables in required length can
connected easily with one-touch be used, so this contributes to reduction in waste of MACHINE VISION
SYSTEMS
connection. unwanted cables.
UV CURING
SYSTEMS
Environmentally
friendly

* Connection cable
Commercially-available
Selection
parts can be used! Guide
Pressure/
* Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available. Digital Display
Pressure/
Head-separated
Flow
* Refer to p.721 for recommended commercially-available connectors.

DP-0
DP-100
DP-M
DP-100 SERIES Ver.2
719 Dual Display Digital Pressure Sensor

FIBER VARIETIES
SENSORS

LASER Short pressure port type is lightweight and takes up little space DP-10□-M
SENSORS
Compact size with a depth of only 30 mm 1.181 in, so
PHOTOELECTRIC Standard type
SENSORS that it can easily fit into narrow spaces. M5 female thread + R 1/8 male thread

MICRO
Further, 10 g lighter than standard types. This reduces
PHOTOELECTRIC the loads on movable parts such as robot arms. Elbow joint
SENSORS
Short pressure
AREA port type DP-10□-M(-P)
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW Short pressure port type
SENSORS DP-10□-M(-P)
INDUCTIVE
PROXIMITY Shortened to
SENSORS
12.5 mm 0.492 in !
PARTICULAR
USE SENSORS Light weight
30g approx.
SENSOR
OPTIONS M5 female thread
30 mm [Material: Stainless steel (SUS)]
SIMPLE 1.181 in
WIRE-SAVING
UNITS *T
 he illustration shows connection using an elbow joint.
The elbow joint is sold separately.
WIRE-SAVING
SYSTEMS

MEASUREMENT M8 plug-in connector types are also available (Only for Europe) DP-11□-E-P-J
SENSORS
STATIC
CONTROL M8 connector
DEVICES Mating cable
CN-24A-C2 (cable length 2 m 6.562 ft)
LASER CN-24A-C5 (cable length 5 m 16.404 ft)
MARKERS

PLC

HUMAN MACHINE
INTERFACES
ENERGY G 1/8 male thread
MANAGEMENT M5 female thread
SOLUTIONS

FA COMPONENTS

MACHINE VISION Flat installation on the wall by shifting the direction Rc1/8 conversion bushing is available. Compatible
SYSTEMS
of the pressure port For short pressure port type with conventional model For short pressure port type
UV CURING
SYSTEMS By mounting the flat By equipping the push-in converter with DP-10□-M(-P),
attachment to DP-10□-M(-P), pressure port can be converted from M5 female thread
pressure port and cable can to Rc1/8 female thread.
now be pulled out in downward, Conventional model DP2 / DP3
Bore diameter conversion to the DP2 / DP3 series is
Selection
left or right directions. Flat series can be switched over to possible.
Guide mounting on surfaces such as DP-100 series.
Pressure/
Digital Display
the wall is made possible.
Conventional model M5 female thread Rc1/8 female thread
Pressure/
Head-separated
Flow Flat attachment
MS-DP1-F□

DP-0 20 mm 20 mm
0.787 in pitch 0.787 in pitch
DP-100
Conversion bushing
DP-M Model No. Pressure port MS-DP1-7

MS-DP1-FM M5 female thread


MS-DP1-FR Rc1/8 female thread
MS-DP1-FN NPT1/8 female thread
3 possible directions to mount MS-DP1-FE G1/8 female thread
DP-100 SERIES Ver.2
Dual Display Digital Pressure Sensor
720

ORDER GUIDE FIBER


SENSORS

LASER
SENSORS
Type Appearance Rated pressure range Model No. Pressure port Comparative output PHOTO-
ELECTRIC
SENSORS
For low pressure −100.0 to +100.0 kPa DP-101 MICRO
Standard M5 female thread PHOTO-
For high pressure −0.100 to +1.000 MPa DP-102 +
ELECTRIC
Asia

SENSORS
NPN open-collector transistor
For low pressure −100.0 to +100.0 kPa DP-101A R 1/8
AREA
Multi-function male thread SENSORS
For high pressure −0.100 to +1.000 MPa DP-102A
SAFETY LIGHT
For low pressure CURTAINS /
−100.0 to +100.0 kPa DP-101-E-P SAFETY
Standard M5 female thread COMPONENTS
For high pressure −0.100 to +1.000 MPa DP-102-E-P + PRESSURE /
PNP open-collector transistor FLOW
For low pressure −100.0 to +100.0 kPa DP-101A-E-P G 1/8 SENSORS
Standard pressure port type

Multi-function male thread


−0.100 to +1.000 MPa DP-102A-E-P
Europe

For high pressure INDUCTIVE


PROXIMITY
SENSORS
For low pressure DP-111-E-P-J
M8 plug-in connector type

−100.0 to +100.0 kPa


Standard M5 female thread PARTICULAR
For high pressure −0.100 to +1.000 MPa DP-112-E-P-J + USE
PNP open-collector transistor SENSORS
For low pressure −100.0 to +100.0 kPa DP-111A-E-P-J G 1/8
Multi-function male thread SENSOR
For high pressure −0.100 to +1.000 MPa DP-112A-E-P-J OPTIONS

DP-101-N NPN open-collector transistor SIMPLE


WIRE-SAVING
For low pressure −100.0 to +100.0 kPa UNITS
DP-101-N-P PNP open-collector transistor
Standard WIRE-SAVING
DP-102-N NPN open-collector transistor
North America

SYSTEMS
For high pressure −0.100 to +1.000 MPa M5 female thread
* CN-14A-C2 DP-102-N-P PNP open-collector transistor
+
( )
MEASURE-
Connector attached MENT
cable 2 m 6.562 ft DP-101A-N NPT 1/8 NPN open-collector transistor SENSORS
For low pressure is attached. −100.0 to +100.0 kPa male thread
DP-101A-N-P PNP open-collector transistor STATIC
Multi-function ( Excluding M8 plug-in
connector type ) DP-102A-N NPN open-collector transistor
CONTROL
DEVICES
For high pressure −0.100 to +1.000 MPa
LASER
DP-102A-N-P PNP open-collector transistor MARKERS
DP-101-M NPN open-collector transistor
For low pressure −100.0 to +100.0 kPa PLC
Short pressure port type

DP-101-M-P PNP open-collector transistor


Standard
DP-102-M NPN open-collector transistor HUMAN
MACHINE
For high pressure −0.100 to +1.000 MPa INTERFACES
DP-102-M-P PNP open-collector transistor
Asia

M5 female thread ENERGY


DP-101A-M NPN open-collector transistor MANAGEMENT
For low pressure −100.0 to +100.0 kPa SOLUTIONS
DP-101A-M-P PNP open-collector transistor
Multi-function FA
DP-102A-M NPN open-collector transistor COMPONENTS
For high pressure −0.100 to +1.000 MPa
DP-102A-M-P PNP open-collector transistor MACHINE
VISION
SYSTEMS

UV
Type without connector attached cable CURING
SYSTEMS
Type without connector attached cable CN-14A-C2 is available.
When ordering this type, suffix “-J” to the Model No. (Excluding M8 plug-in connector type and short pressure port type)
(e.g.) Type without connector attached cable of DP-101-N is “DP-101-N-J”

Selection
Accessory Guide
Pressure/
• CN-14A-C2 Digital Display
(Connector attached cable 2 m 6.562 ft) Pressure/
Head-separated
Flow

DP-0

DP-100

DP-M
DP-100 SERIES Ver.2
721 Dual Display Digital Pressure Sensor

FIBER
SENSORS
OPTIONS
LASER
SENSORS Connector attached cable
PHOTO-
Designation Model No. Description • CN-14A-C□
ELECTRIC
SENSORS
• CN-14A-R-C□
MICRO CN-14A-C1 Length: 1 m 3.281 ft
PHOTO- 0.2 mm2 4-core cabtyre cable with
ELECTRIC Connector CN-14A-C2 (Note) Length: 2 m 6.562 ft
SENSORS attached cable connector on one end
CN-14A-C3 Length: 3 m 9.843 ft Cable outer diameter: ø3.7 mm ø0.146 in
AREA
SENSORS CN-14A-C5 Length: 5 m 16.404 ft
SAFETY LIGHT CN-14A-R-C1 Length: 1 m 3.281 ft
CURTAINS /
Connector 0.2 mm2 4-core bending-resistant cabtyre
SAFETY CN-14A-R-C2 Length: 2 m 6.562 ft
COMPONENTS attached cable cable with connector on one end M8 connector attached cable
PRESSURE /
FLOW
SENSORS
(
Bending-resistant
cable ) CN-14A-R-C3
CN-14A-R-C5
Length: 3 m 9.843 ft
Length: 5 m 16.404 ft
Cable outer diameter: ø3.7 mm ø0.146 in
• CN-24A-C□
INDUCTIVE
PROXIMITY M8 connector CN-24A-C2 Length: 2 m 6.562 ft For M8 plug-in connector type
SENSORS The connector on one end
attached cable
PARTICULAR CN-24A-C5 Length: 5 m 16.404 ft Cable outer diameter: ø4 mm ø0.157 in
USE
SENSORS Connector CN-14A Set of 10 housings and 40 contacts
SENSOR Allows sensors to be installed on the flooring or ceiling.
OPTIONS Sensor MS-DP1-1 Multiple sensors can also be mounted closely.
mounting 31.4 ø4
SIMPLE bracket Allows sensors to be installed on the wall. Multiple sensors 1.236 ø0.157
WIRE-SAVING MS-DP1-5 can also be mounted closely.
UNITS

Allows installation to panels with thickness of 1 to 6 mm 0.039


WIRE-SAVING
SYSTEMS MS-DP1-2 to 0.236 in. Multiple sensors can also be mounted closely. ø9
Panel mounting ø0.354 (Unit: mm in)
MEASURE- bracket Allows replacement from DP2 / DP3 series to DP-100 series. For newly designed
MENT MS-DP1-4 set-up, please use panel mounting bracket MS-DP1-2 for panel mounting.
SENSORS

STATIC Protects the adjustment surfaces of sensors. Sensor mounting bracket


CONTROL MS-DP1-3 (Can be attached when using the panel mounting bracket MS-DP1-2) • MS-DP1-1
DEVICES Front protection
cover Protects the adjustment surfaces of sensors.
LASER DPX-04 M3 (length 6 mm 0.236 in)
MARKERS (Can be attached when using the panel mounting bracket MS-DP1-4) screws with washers

Conversion
MS-DP1-7
By equipping with DP-10□-M(-P), pressure port can be converted to (Accessory for
MS-DP1-1 )
PLC bushing Rc1/8 female thread. Replacement from DP2 / DP3 series is possible.
HUMAN MS-DP1-FM M5 female thread For DP-10□-M(-P) Sensor mounting
MACHINE bracket
INTERFACES Flat MS-DP1-FR Rc1/8 female thread Pressure port and cable can now be
MS-DP1-1
attachment pulled out in downward, left or right
ENERGY MS-DP1-FN NPT /8 female thread directions. Flat mounting on surfaces
1
MANAGEMENT
SOLUTIONS MS-DP1-FE G1/8 female thread such as the wall is made possible.
FA Note: The connector attached cable CN-14A-C2 is supplied with the DP-100 series. • MS-DP1-5
COMPONENTS (Excluding M8 plug-in connector type). M3 (length 6 mm 0.236 in)
screws with washers
MACHINE
VISION
SYSTEMS (Accessory for
MS-DP1-5 )
Panel mounting bracket, Front protection cover
UV
CURING • MS-DP1-2 • MS-DP1-4 DP2 / DP3
SYSTEMS Sensor mounting
• MS-DP1-3 bracket
Front protection cover
DP
2-2
0

ñ101
.3kP

MS-DP1-5
a

DPX-04 (optional) Remove


OUT
1

OUT
0-AD 2
J
MOD
E

can be installed on
MS-DP1-4.
Front protection cover Remove
MS-DP1-3
Selection
Guide
Insert
Pressure/
Mounting holes
Conversion bushing
Digital Display DP-100
Pressure/ for DP2 / DP3 series • MS-DP1-7 M5 female Rc1/8 female
Head-separated can be used as is. thread thread
Panel mounting bracket Panel mounting bracket MS-DP1-4
Flow MS-DP1-2

DP-0 Flat attachment


• MS-DP1-FM • MS-DP1-FR
DP-100
• MS-DP1-FN Conversion bushing
• MS-DP1-FE MS-DP1-7
DP-M
Recommended connector
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Net weight: MS-DP1-FM 15g approx.
Note: Contact the manufacturer for details of the
MS-DP1-FR/FN/FE 25g approx. recommended products.
Two M3 (length 8 mm 0.315 in) screws,
two M4 (length 20 mm 0.787 in) screws Recommended crimping tool
are attached.
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the
recommended products.

Recommended connector (e-CON)


Applicable connector: 37104-3122-000 FL
(Manufactured by 3M Japan Limited)
Note: Contact the manufacturer for details of the
recommended products.
DP-100 SERIES Ver.2
Dual Display Digital Pressure Sensor
722

SPECIFICATIONS FIBER
SENSORS

LASER
Standard Multi-function SENSORS
Type
For low pressure For high pressure For low pressure For high pressure PHOTO-
ELECTRIC
Asia (Note 2) DP-101(-M)(-P) DP-102(-M)(-P) DP-101A(-M)(-P) DP-102A(-M)(-P) SENSORS
Model No.

MICRO
Europe DP-101-E-P DP-102-E-P DP-101A-E-P DP-102A-E-P PHOTO-
ELECTRIC
M8 plug-in connector type DP-111-E-P-J DP-112-E-P-J DP-111A-E-P-J DP-112A-E-P-J SENSORS

Item North America (Note 2) DP-101-N(-P) DP-102-N(-P) DP-101A-N(-P) DP-102A-N(-P) AREA


SENSORS
CE marking directive compliance EMC Directive, RoHS Directive
SAFETY LIGHT
Type of pressure Gauge pressure CURTAINS /
SAFETY
Rated pressure range −100.0 to +100.0 kPa −0.100 to +1.000 MPa −100.0 to +100.0 kPa −0.100 to +1.000 MPa COMPONENTS

−101.0 to +101.0 kPa −0.101 to +1.010 MPa −101.0 to +101.0 kPa −0.101 to +1.010 MPa PRESSURE /
FLOW
−1.030 to +1.030 kgf/cm2 −101 to +1,010 kPa −1.030 to +1.030 kgf/cm2 −101 to +1,010 kPa SENSORS
−1.010 to +1.010 bar −1.03 to +10.30 kgf/cm2 −1.010 to +1.010 bar −1.03 to +10.30 kgf/cm2 INDUCTIVE
Set pressure range −14.64 to +14.64 psi −14.64 to +14.64 psi PROXIMITY
−1.01 to +10.10 bar −1.01 to +10.10 bar SENSORS
−757 to +757 mmHg −757 to +757 mmHg
−29.8 to 29.8 inHg −14.6 to +146.4 psi −29.8 to 29.8 inHg −14.6 to +146.4 psi
PARTICULAR
USE
Pressure withstandability 500 kPa 1.5 MPa 500 kPa 1.5 MPa SENSORS
Applicable fluid Non-corrosive gas SENSOR
OPTIONS
Selectable unit For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less SIMPLE
WIRE-SAVING
Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) UNITS
Power consumption ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)
WIRE-SAVING
360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage) SYSTEMS
<Asia (NPN output), North America (NPN output)> <Asia (PNP output), Europe, North America (PNP output)>
Comparative output NPN open-collector transistor PNP open-collector transistor MEASURE-
MENT
Comparative output 1, • Maximum sink current: 100 mA • Maximum source current: 100 mA SENSORS
Comparative output 2 (Note 3) • Applied voltage: 30 V DC or less (between comparative output and 0 V) • Applied voltage: 30 V DC or less (between comparative output and +V)
STATIC
• Residual voltage: 2 V or less (at 100 mA sink current) • Residual voltage: 2 V or less (at 100 mA source current) CONTROL
DEVICES
Output operation / Output modes NO/NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode
Hysteresis Minimum 1 digit (variable) (however, 2 digits when using psi unit) LASER
MARKERS
Repeatability ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits) ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits)
Response time 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation PLC

Short-circuit protection Incorporated HUMAN


<Asia (NPN output), North America (NPN output)> <Asia (PNP output), Europe, North America (PNP output)> MACHINE
External input (Note 4) INTERFACES
ON voltage: 0.4 V DC or less ON voltage: 5 V to +V DC
Auto-reference function / ENERGY
OFF voltage: 5 to 30 V DC, or open OFF voltage: 0.6 V DC or less, or open
Remote zero-adjustment MANAGEMENT
Input impedance: 10 kΩ approx. Input impedance: 10 kΩ approx. SOLUTIONS
function
Input time: 1 ms or more Input time: 1 ms or more
FA
Output voltage: 1 to 5 V DC Output voltage: 0.6 to 5 V COMPONENTS
Zero point: within 3 V ±5 % F.S. Zero point: within 1 V ±5 % F.S.
Analog voltage output (Note 4) Span: within 4 V ±5 % F.S. Span: within 4.4 V ±5 % F.S. MACHINE
VISION
Linearity: within ±1 % F.S. Linearity: within ±1 % F.S. SYSTEMS
Output impedance: 1 kΩ approx. Output impedance: 1 kΩ approx. UV
Output current: 4 to 20 mA Output current: 2.4 to 20 mA CURING
SYSTEMS
Zero point: 12 mA ±5 % F.S. Zero point: 4 mA ±5 % F.S.
Analog current output (Note 4) Span: 16 mA ±5 % F.S. Span: 17.6 mA ±5 % F.S.
Linearity: within ±1 % F.S. Linearity: within ±1 % F.S.
Load resistance: 250 Ω (max.) Load resistance: 250 Ω (max.)
Display 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Selection
−101.0 to +101.0 kPa −0.101 to +1.010 MPa −101.0 to +101.0 kPa −0.101 to +1.010 MPa Guide
−1.030 to +1.030 kgf/cm2 −101 to +1,010 kPa −1.030 to +1.030 kgf/cm2 −101 to +1,010 kPa Pressure/
−1.010 to +1.010 bar −1.03 to +10.30 kgf/cm 2 −1.010 to +1.010 bar −1.03 to +10.30 kgf/cm2 Digital Display
Displayable pressure range −14.64 to +14.64 psi −14.64 to +14.64 psi Pressure/
−1.01 to +10.10 bar −1.01 to +10.10 bar Head-separated
−757 to +757 mmHg −757 to +757 mmHg
−29.8 to 29.8 inHg −14.6 to +146.4 psi −29.8 to 29.8 inHg −14.6 to +146.4 psi
Flow
Orange LED Orange LED
Indicator
( Comparative output 1 operation indicator, comparative output 2 operation indicator:
Lights up when each comparative output is ON )( Comparative output 1 operation indicator: Lights up when comparative output is ON,
Analog voltage output operation indicator: Lights up when setting ) DP-0
Protection IP40 (IEC)
Environmental resistance

DP-100
Ambient temperature −10 to +50 °C +14 to +122 °F, Storage: −10 to +60 °C +14 to +140 °F
Ambient humidity 35 to 85 % RH (No dew condensation or icing allowed), Storage: 35 to 85 % RH DP-M

Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
Vibration resistance
(when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Temperature characteristics Within ±0.5 % F.S. (at +20 °C +68 °F) Within ±1 % F.S. (at +20 °C +68 °F) Within ±0.5 % F.S. (at +20 °C +68 °F) Within ±1 % F.S. (at +20 °C +68 °F)
Pressure port Asia: M5 female thread + R (PT) 1/8 male thread [excluding DP-□-M(-P)], Europe: M5 female thread + G 1/8 male thread, North America: M5 female thread + NPT 1/8 male thread
Material Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Connecting method / Cable length Connector / Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable.
Weight Net weight: 40 g approx. (DP-10□-M(-P): 30 g approx.), Gross weight: 130 g approx. (DP-10□-M(-P):120 g approx.)
Accessories CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc. (excluding M8 plug-in connector type)
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Model Nos. of Asia type having “-M” are short pressure port type. Model Nos. of Asia and North America types having the suffix “-P” are PNP output type.
3) Only standard type is equipped with comparative output 2.
4) Cannot be used at the same time.
DP-100 SERIES Ver.2
723 Dual Display Digital Pressure Sensor

FIBER
SENSORS
I/O CIRCUIT AND WIRING DIAGRAMS
LASER
SENSORS DP-10□ NPN output type
PHOTO-
ELECTRIC I/O circuit diagrams Terminal No. Multi-function type Terminal No.
SENSORS
Color code of connector attached cable
Standard type Color code of connector attached cable
MICRO (Brown) +V
PHOTO- (Brown) +V 1
ELECTRIC 1 5V D1
SENSORS D1 (Black) D3 (White) Analog output
D2 Load Tr1

Sensor circuit
Comparative output 1 3
or External input Load
Sensor circuit

AREA Tr1 2
Load + 12 to 24 V DC
SENSORS 100 mA max. + 12 to 24 V DC 1kΩ D2 (Black) Comparative output 1 ±10 %
ZD1 D3 (White) Comparative output 2 Tr2 2 −
SAFETY LIGHT − ±10 %
CURTAINS / Tr2 3
100 mA max.
SAFETY 100 mA max. ZD
COMPONENTS ZD2
(Blue) 0 V
PRESSURE / (Blue) 0 V 4
4
FLOW
SENSORS Internal circuit Users’ circuit
Internal circuit Users’ circuit
INDUCTIVE Symbols • • • D1 to D3 : Reverse supply polarity protection diode
PROXIMITY Symbols • • • D1 to D3 : Reverse supply polarity protection diode
SENSORS ZD : Surge absorption zener diode
ZD1, ZD2 : Surge absorption zener diode Tr1 : PNP input transistor
PARTICULAR Tr1, Tr2 : NPN output transistor Tr2 : NPN output transistor
USE
SENSORS
Terminal arrangement diagram
SENSOR
Terminal Designation
OPTIONS 1 +V
SIMPLE 2 Comparative output 1
WIRE-SAVING
UNITS Standard type: Comparative output 2
3
Multi-function type: Analog output or External input
WIRE-SAVING
SYSTEMS 1 2 3 4 4 0V
MEASURE-
MENT
SENSORS DP-10□-P PNP output type
STATIC
CONTROL I/O circuit diagrams Terminal No.
Multi-function type Terminal No.
DEVICES Color code of connector attached cable
Standard type Color code of connector attached cable
(Brown) +V
LASER 1
MARKERS (Brown) +V D1
1
D ZD
Tr1 100 mA max.
Sensor circuit

PLC ZD1
100 mA max.
Sensor circuit

2 +
(Black) Comparative output 1 12 to 24 V DC
Tr1 2 + 1kΩ D3 ±10 %
ZD2 (Black) Comparative output 1 12 to 24 V DC −
HUMAN (White) Analog output Load
MACHINE 100 mA max. − ±10 % Tr2 3
INTERFACES Load D2 or External input
Tr2 3
(White) Comparative output 2 (Blue) 0 V
ENERGY Load 4
MANAGEMENT (Blue) 0 V
SOLUTIONS 4
Internal circuit Users’ circuit
Internal circuit Users’ circuit
FA Symbols • • • D1 to D3 : Reverse supply polarity protection diode
COMPONENTS
Symbols • • • D : Reverse supply polarity protection diode ZD : Surge absorption zener diode
MACHINE ZD1, ZD2 : Surge absorption zener diode Tr1 : PNP output transistor
VISION Tr1, Tr2 : PNP output transistor Tr2 : NPN input transistor
SYSTEMS

UV Terminal arrangement diagram Terminal Designation


CURING
SYSTEMS
1 +V
2 Comparative output 1
Standard type: Comparative output 2
3
Multi-function type: Analog output or External input
Selection 1 2 3 4 4 0V
Guide
Pressure/
Digital Display
Pressure/
DP-11□-E-P-J PNP output type
Head-separated
I/O circuit diagrams Terminal No. Multi-function type Terminal No.
Flow Color code of connection cable
Standard type Color code of connection cable
(Brown) +V
1
(Brown) +V
1 D1
DP-0 D ZD
Tr1 100 mA max.
Sensor circuit

ZD1
100 mA max.
Sensor circuit

DP-100 4 + 12 to 24 V DC
Tr1 1k (Black) Comparative output 1
4 + 12 to 24 V DC ±10 %
ZD2 (Black) Comparative output 1 −
DP-M 100 mA max. − ±10 % Tr2 2
(White) Analog voltage output Load
Tr2 2
Load D2 or External input
(White) Comparative output 2
Load (Blue) 0 V
3
(Blue) 0 V
3
Internal circuit Users’ circuit
Internal circuit Users’ circuit
Symbols • • • D1, D2 : Reverse supply polarity protection diode
Symbols • • • D : Reverse supply polarity protection diode ZD : Surge absorption zener diode
ZD1, ZD2 : Surge absorption zener diode Tr1 : PNP output transistor
Tr1, Tr2 : PNP output transistor Tr2 : NPN input transistor

Terminal arrangement diagram Terminal Designation


1
2
1 +V
Standard type: Comparative output 2
2
3 4 Multi-function type: Analog output or External input
3 0V
4 Comparative output 1
DP-100 SERIES Ver.2
Dual Display Digital Pressure Sensor
724

PRECAUTIONS FOR PROPER USE Refer to p.1566 for general precautions. FIBER
SENSORS

LASER
• Never use this product as a sensing device for • The MS-DP1-4 panel mounting bracket is available when SENSORS

personnel protection. switching from the DP2 / DP3 series.


PHOTO-
• In case of using sensing devices for personnel DP2 / DP3 ELECTRIC
SENSORS
protection, use products which meet laws and standards,
DP
2-2
0

MICRO
ñ10
1.3k
Pa

Front protective cover


such as OSHA, ANSI or IEC etc., for personnel
OUT

Remove
1

0-AD
OUT
2

PHOTO-
DPX-04 (optional)
J
MO
DE

ELECTRIC
protection applicable in each region or country. can be installed on SENSORS
MS-DP1-4.
• The DP-100 series is designed for use with non-corrosive AREA
gas. It cannot be used with liquid or corrosive gas. Remove SENSORS

SAFETY LIGHT
CURTAINS /
SAFETY
Part description Insert COMPONENTS
DP-100 PRESSURE /
Mounting holes FLOW
Main display for DP2 / DP3 series SENSORS
can be used as is.
INDUCTIVE
Comparative output 1 operation indicator PROXIMITY
Sub display SENSORS
Comparative output 2 operation indicator Panel mounting bracket MS-DP1-4
Work as analog voltage output operation PARTICULAR
indicator in Multi-function type USE
SENSORS

Mode selection Decrement • An conversion bushing is available for when using the DP-10□-M SENSOR
key key short pressure port type. It can be used to switch between this OPTIONS
Increment model and the DP2 / DP3 series. When connecting to the SIMPLE
key
pressure port, use a M5 female thread Rc 1 8 female thread WIRE-SAVING
Wiring tightening torque of
UNITS

• Make sure that the power supply is off while wiring. 1.0 N·m or less. WIRE-SAVING
SYSTEMS
• Verify that the supply voltage variation is within the rating.
MEASURE-
• If power is supplied from a commercial switching regulator, MENT
SENSORS
ensure that the frame ground (F.G.) terminal of the power
STATIC
supply is connected to an actual ground. Conversion bushing MS-DP1-7
CONTROL
DEVICES
• In case noise generating equipment (switching regulator, • The MS-DP1-F□ flat attachment is available for when using the DP-10□-M
inverter motor, etc.) is used in the vicinity of this sensor, short pressure port type. If using the MS-DP1-F□ flat attachment (optional), LASER
MARKERS
connect the frame ground (F.G.) terminal of the equipment install by following the procedures given below.
to an actual ground. 1 Decide the direction of this product to mount with the sensor. PLC

• Do not run the wires together with high-voltage lines or HUMAN


power lines or put them in the same raceway. This can MACHINE
INTERFACES
cause malfunction due to induction.
ENERGY
• Incorrect wiring will cause problems with operation. MANAGEMENT
SOLUTIONS

FA
Connection Pressure port Pressure port Pressure port
COMPONENTS

faces leftward faces rightward


• Do not apply stress directly to Connector
faces downward MACHINE
VISION
the connection cable leader or attached cable Note: It is not possible to mount this product such SYSTEMS
to the connector. [CN-14A(-R)-C□] that the pressure port faces upward.
UV
CURING
SYSTEMS

Mounting
Pressure port
• MS-DP1-1 / MS-DP1-5 sensor mounting brackets are faces upward
available separately, and it should be used for mounting. 2 Mount this product with the M3 female threads of the
Selection
Guide
When tightening the sensor to the sensor mounting bracket, sensor by using the attached M3 (length 8 mm 0.315 in) Pressure/
use a tightening torque of 0.5 N·m or less. screws. The tightening torque should be 0.5 N·m or less.
Digital Display
Pressure/
M3 (length 6 mm 0.236 in) M3 female thread Head-separated
screws with washers
Flow
(Accessory for MS-DP1-1
and MS-DP1-5 ) M3 (length 8 mm 0.315 in)
screw (Accessory)

DP-0

Sensor mounting bracket M3 female thread


DP-100
MS-DP1-1 (Optional)
DP-M

3 Mount this product with the mounting surface by using


the attached M4 (length 20 mm 0.787 in) screws. The
• The MS-DP1-2 panel mounting bracket (optional) and the tightening torque should be 1.2 N·m or less.
MS-DP1-3 front protection cover (optional) are also
available.
Groove

Front protection cover


MS-DP1-3 (optional) Connector attached cable
M4 (length 20 mm 0.787 in)
screw (Accessory)
Note: Take care that if the cable with connector is sticking out of the side
groove of this product when mounting, the cable may disconnected.
Panel mounting bracket
MS-DP1-2 (optional)
DP-100 SERIES Ver.2
725 Dual Display Digital Pressure Sensor

FIBER
SENSORS
PRECAUTIONS FOR PROPER USE Refer to p.1566 for general precautions.

LASER
SENSORS Conditions in use for CE conformity Flat attachment
PHOTO- • The DP-100 series is a CE conformity product complying • Make sure to mount MS-DP1-F□ with the sensor properly.
ELECTRIC
SENSORS
with EMC Directive. The harmonized standard with regard to If it is not mounted properly, air leakage may occur.
MICRO immunity that applies to this product is EN 61000-6-2 and the • Take care that the excessive mounting and dismounting of
PHOTO-
ELECTRIC
following condition must be met to conform to that standard. this product may cause deterioration of the O-ring.
SENSORS
Condition • If you touch the O-ring of MS-DP1-F□, or any scratch or
AREA
SENSORS dust, etc. is attached to it, air leakage may occur and the
• The line to connect with this sensor should be less than sensing performance may deteriorate.
SAFETY LIGHT
CURTAINS / 30 m 98.425 ft. Take sufficient care when using and storing MS-DP1-F□.
SAFETY
COMPONENTS
PRESSURE /
FLOW
Piping Others
SENSORS • If connecting a commercially-available 12 mm 0.472 in
spanner
• Use within the rated pressure range.
INDUCTIVE
PROXIMITY coupling to the pressure port, attach a • Do not apply pressure exceeding the pressure withstandability
SENSORS
12 mm 0.472 in spanner (14 mm value. The diaphragm will get damaged and correct operation
PARTICULAR
0.551 in spanner for DP-100-E type) shall not be maintained.
USE
SENSORS
to the hexagonal section of the • Do not use during the initial transient time (0.5 sec. approx.)
after the power supply is switched on.
SENSOR pressure port to secure it, and tighten
OPTIONS • Avoid dust, dirt, and steam.
at a torque of 9.8 N·m or less. If it is
SIMPLE • Take care that the sensor does not come in direct contact with
tightened using excessive torque, it may
WIRE-SAVING
UNITS water, oil, grease, or organic solvents, such as, thinner, etc.
damage the coupling or the pressure port. • Do not insert wires, etc., into the pressure port. The
WIRE-SAVING
SYSTEMS
In addition, wrap sealing tape around the coupling when diaphragm will get damaged and correct operation shall not
connecting it to prevent leaks. be maintained.
MEASURE-
MENT • If connecting a commercially-available joint to the • Do not operate the keys with pointed or sharp objects.
SENSORS

STATIC
pressure port of the DP-10□-M(-P), hold the main unit in
CONTROL
DEVICES
your hand to steady it, and tighten to a torque of 1.0 N·m RUN mode
or less. If it is tightened to an excessive torque, the joint or • This is the normal operating mode.
LASER
MARKERS the main unit may become damaged.
• If connecting a commercially-available joint to the Setting item Description
PLC
pressure port of the MS-DP1-7, tighten to a torque of 9.8 The threshold values for ON/OFF operation can be
Threshold value changed directly by pressing the increment key
HUMAN N·m or less. 14 mm 0.551 in setting
MACHINE (UP) and the decrement key (DOWN).
INTERFACES spanner
ENERGY Zero-adjustment This forces the pressure value display to be reset to zero when
MANAGEMENT function the pressure port is open on the atmospheric pressure side.
SOLUTIONS
Key lock function Stops key operations from being accepted.
FA
COMPONENTS
Displays the peak value and bottom value for fluctuating
Peak hold /
MACHINE pressure. The peak value appears in the main display,
bottom hold function
VISION and the bottom value appears in the sub display.
SYSTEMS

UV
CURING • The tightening torque should be 1 N·m or less when
SYSTEMS MENU SETTING mode
connecting a coupling to the pressure port of MS-DP1-FM.
• If the mode selection key is pressed and held for 2
seconds in RUN mode, the mode will switch to MENU
SETTING mode.
Selection
• If the mode selection key is pressed while a setting is
Guide being made, the mode will switch to RUN mode. In this
Pressure/ case, the settings that have been changed will be entered.
Digital Display
Pressure/
Head-separated
Setting item Description
Pressure port
Flow
Coupling (Purchase separately.) Comparative output 1
Sets the output mode for comparative output 1.
output mode setting

Comparative output 2 output mode


DP-0 Sets the output mode for comparative output 2.
setting (standard type only)
• When connecting the coupling to the pressure port of
DP-100
MS-DP1-FR/FE/FN, hold the pressure port with a 14 mm Analog output / external Allows switching between analog voltage output /
DP-M 0.551 in spanner and make sure that the tightening torque input switching analog current output, and auto-reference input /
(multi-function type only) remote zero-adjust-ment input.
is 9.8 N·m or less.
In addition, in order to prevent any leakage, wind a sealing NO/NC switching Sets normally open (NO) or normally closed (NC).
tape on the coupling when connecting. Sets the response time.
The response time can be selected from 2.5 ms,
Response time setting
5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms,
500 ms, 1,000 ms and 5,000 ms.

Allows the color for the main display to be changed.


Display color switching The colors can be set to ‘red / green’ or ‘green / red’
for main display to correspond to ON/OFF output, or it can be fixed
at ‘red’ or ‘green’ all the time.
14 mm 0.551 in
spanner
Unit switching Pressure unit can be changed.

Note: Do not tighten the pressure port by holding the product with the
spanner. It may cause the product breakage.
DP-100 SERIES Ver.2
Dual Display Digital Pressure Sensor
726

PRECAUTIONS FOR PROPER USE Refer to p.1566 for general precautions. FIBER
SENSORS

LASER
PRO mode Table of codes SENSORS

• If the mode selection key is pressed and held for 5 PHOTO-


seconds in RUN mode, the mode will switch to PRO 2nd digit 4th digit ELECTRIC
1st digit Multi-function 3rd digit Standard SENSORS
mode.

Code
Standard type type type only MICRO
• If the mode selection key is pressed while a setting is Comparative output 1 NO/NC
output mode
Comparative output 2 NO/NC Analog voltage output / Threshold Display color for Display
switching output mode switching External input value display main display color linking
PHOTO-
ELECTRIC
being made, the mode will switch to RUN mode. In this SENSORS
Analog voltage Comparative
case, the settings that have been changed will be entered. NO OFF OFF
output
P-1, Lo-1 Red
output 1
AREA
SENSORS
EASY when ON
Auto- Comparative
Setting item Description NC NO reference Hi-1
SAFETY LIGHT
output 2 CURTAINS /
Changes the information in the sub display EASY SAFETY
Remote Comparative COMPONENTS
NO NC
Sub display switching during RUN mode operation to the desired zero-adjustment P-2, Lo-2 Green output 1 PRESSURE /
alphanumeric display. Hysteresis FLOW
Analog current when ON Comparative SENSORS
NC NO Hi-2
Display refresh rate Changes the display refresh rate for the output output 2
switching pressure value displayed in the main display. Hysteresis INDUCTIVE
— Comparative PROXIMITY
NO NC ADJ. SENSORS
Window Always output 1
Hysteresis fix value Sets the hysteresis for EASY mode and window comparator red Comparative PARTICULAR
switching comparator mode. (8 steps) NC NO — — USE
Window output 2 SENSORS
Linked display color Allows the display color for the main display to comparator Comparative
switching be switched in line with the output operation for — — NC — — SENSOR
Always output 1 OPTIONS
(standard type only) comparative output 1 or comparative output 2. green Comparative
— — — — — —
Allows power consumption to be reduced by output 2 SIMPLE
ECO mode setting WIRE-SAVING
dimming the display or turning it off. UNITS

Allows the setting details to be checked via WIRE-SAVING


Setting check code SYSTEMS
codes.
MEASURE-
Allows the setting details for the master sensor MENT
Setting copy mode SENSORS
to be copied to slave sensors.
STATIC
Reset setting Resets the settings to the factory settings. CONTROL
DEVICES

5th digit 6th digit 7th digit 8th digit


Code

LASER
MARKERS
Response time Unit switching Display refresh rate ECO mode
2.5 ms MPa 250 ms OFF
kPa 500 ms STD PLC
5 ms
10 ms kgf/cm2 1,000 ms FULL
— HUMAN
25 ms bar — MACHINE
50 ms psi — — INTERFACES
100 ms mmHg — — ENERGY
inchHg — — MANAGEMENT
250 ms SOLUTIONS
500 ms — — —
1,000 ms — — — FA
COMPONENTS
5,000 ms — — —
MACHINE
VISION
SYSTEMS
DIMENSIONS (Unit: mm in) The CAD data can be downloaded from the website. UV
CURING
SYSTEMS
DP-10□(-P) Sensor
42.5
30 1.673 20 Europe
25.5 7.5 9.5 Connector 10 7
1.181 1.004 0.295 0.374 0.787
0.394 0.276

Selection
30 20 12 14 Guide
1.181 0.472 0.551
0.787 Pressure/
G 1/ 8 Digital Display
R (PT) 1/ 8 male thread
male thread Pressure/
1.5 (North America: NPT 1/ 8) M5 female thread Head-separated
0.059 M3 female thread, 4 0.157 deep Flow

DP-10□-M(-P) Sensor
DP-0
30
30 1.181 20
25.5 4.5 0.787 DP-100
1.181 1.004 0.177
DP-M

30 ø8.3 20
1.181 ø0.327 0.787 connector

1.5 M3 female thread, M5 female thread,


0.059 4 0.157 deep 4 0.157 deep

DP-11□-E-P-J Sensor
47.5
20
30 25.5 1.870 7 0.787
1.181 1.004 0.276 M8 connector

9.5
30 0.374 20
1.181 0.787 14
0.551
4.5 0.177
1.5 15 G 1/8 male thread M5 female thread
0.059 0.591 7 0.276 M3 female thread,
4 0.157 deep
DP-100 SERIES Ver.2
727 Dual Display Digital Pressure Sensor

FIBER
SENSORS
DIMENSIONS (Unit: mm in) The CAD data can be downloaded from the website.

LASER
SENSORS MS-DP1-1 Sensor mounting bracket (Optional)
PHOTO-
ELECTRIC ø2.3 Assembly dimensions
SENSORS ø0.091
MICRO
Mounting drawing with DP-10□(-P)
PHOTO- 22 2-R2.1 R0.083
ELECTRIC 14.5 9.5 0.866 9.5
SENSORS 0.571 0.374 1 0.374
0.039
AREA
SENSORS 4.2 2-R2.1 R0.083 14.5
0.165 22 0.571
SAFETY LIGHT 0.866
CURTAINS / 4.2
SAFETY 30 0.165 25.5
COMPONENTS 2-ø3.5 ø0.138 1.004
1.181 42.5
PRESSURE / 20 1.673
FLOW 0.787
SENSORS 13
0.512 7.5 9.5
INDUCTIVE 0.295 0.374
PROXIMITY
SENSORS 20 R13
0.787 R0.512 (0.209
5.3
) 44
45
1.772 30 12
PARTICULAR
USE 5.5 1.732 1.181 45 0.472
SENSORS t2 0.217
t 0.079 20 1.772 30
0.787 1.181
SENSOR 15
OPTIONS 0.591 1.5
0.059
SIMPLE Material: Cold rolled carbon steel (SPCC) 30 t2
WIRE-SAVING (Trivalent uni-chrome plated) 1.181 t 0.079
UNITS
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
WIRE-SAVING
SYSTEMS

MEASURE-
MS-DP1-5 Sensor mounting bracket (Optional)
MENT
SENSORS Assembly dimensions
STATIC Mounting drawing with DP-10□-M(-P)
CONTROL
DEVICES R6.75
22.75 R0.266
0.896
LASER
MARKERS
29.5 ø4.5
1.161 16
ø0.177 0.630
PLC 20 28
4.5 0.787 8.5 1.102
0.177 0.335
HUMAN
MACHINE
INTERFACES 30
1.181
ENERGY 44.5 4.5
MANAGEMENT 0.177
SOLUTIONS 30 1.752
20 1.181
FA 0.787 (1.949
49.5
) ø8.3
COMPONENTS
ø0.327
t 1.5 20 49.5
MACHINE 13.5 2-ø3.5 ø0.138 t 0.059 0.787 28.5 1.949
VISION 1.122
SYSTEMS 0.531
20 1.5
UV 0.787 ø4.5 0.059
CURING ø0.177 20 4.5 28 t 1.5
SYSTEMS Material: Stainless steel (SUS304) 0.787 0.177 1.102 t 0.059
29.5 53.5
Two M3 (length 6 mm 0.236 in) screws with washers are attached. 2.106
1.161
30
1.181

MS-DP1-2 MS-DP1-3 Panel mounting bracket (Optional), Front protection cover (Optional)
Selection
Guide Assembly dimensions
Pressure/
Digital Display Mounting drawing with DP-10□(-P) Panel cut-out dimensions
Pressure/ When 1 unit is installed
Head-separated
0
31−0.4
Flow 0
1.220 −0.016
0
31−0.4
0
(Note 2) 1.220 −0.016
DP-0
7.2 18.3 7.5 9.5
DP-100 ( 1.547
39.3
) 0.283
11
0.720 0.295 0.374
34.5 0.433 When “n” units are installed horizontally in series When “n” units are installed vertically in series
DP-M 1.358 0
31−0.4
0
Front 31 1.220 Xn + 3.5 0.138 X (n-1) 1.220 −0.016

(
34.5 20
1.358 0.787 ) protection
cover
12 (Note 2)
0.472 0
0
31−0.4
1.220 −0.016
R 1/ 8 55 2.165 31 1.220 Xn + 3.5 0.138 X (n-1)
50 male thread (Note 1) or more
1.969 8.7
33.4 0.343 Panel thickness dimension
1.315 1 to 6 mm 0.039 to 0.236 in

33.4 Connector 55 2.165


1.315 M5 female thread, or more
4 0.157 deep Note: The panel thickness should be Note: The panel thickness should be
1 to 6 mm 0.039 to 0.236 in. 1 to 6 mm 0.039 to 0.236 in.
M3 female thread,
(52 2.047 max) 4 0.157 deep
View A
Material: Polyacetal (Panel mounting bracket)
Polycarbonate (Front protection cover)

Notes: 1) DP-10□-E-P has a G1/8 male thread. DP-10□-N (-P)has a NPT1/8 male thread.
2) In case of DP-10□-E-P, the dimension 7.5 become to be 10, the dimension 9.5 become to be 7 and the dimension 12 become to be 14.
DP-100 SERIES Ver.2
Dual Display Digital Pressure Sensor
728

DIMENSIONS (Unit: mm in) The CAD data can be downloaded from the website. FIBER
SENSORS

LASER
MS-DP1-4 Panel mounting bracket (Replacement from conventional model) (Optional) SENSORS

PHOTO-
Assembly dimensions ELECTRIC
SENSORS
Mounting drawing with DP-10□(-P) Panel cut-out dimensions MICRO
PHOTO-
36
( )
42.7 ELECTRIC
1.417 SENSORS
1.681
40
1.575
(0.3829.7) 26.5
1.043 R 1/ 8
56
2.205 AREA
6.5 0.256 male thread SENSORS
30 (Note 1)
1.181 3 0.118 36 +0.5
0 SAFETY LIGHT
1.417 +0.020
0 CURTAINS /
Connector SAFETY
40 30 42.7 12 COMPONENTS
0.472 M5 female 36 +0.5
1.575 1.181 1.681 thread
0
PRESSURE /
Panel mounting 80 1.417+0.020
0 FLOW
3.150 SENSORS
bracket body Spacer
Front protection cover
INDUCTIVE
(DPX-04) 8 PROXIMITY
0.315 Panel mounting SENSORS
Panel thickness dimension 1 to 3.2 mm bracket
0.039 to 0.126 in PARTICULAR
USE
SENSORS
Material: Nylon 6 (Panel mounting bracket body)
Stainless steel (SUS304) (Panel mounting bracket) SENSOR
Cold rolled carbon steel (SPCC) (Trivalent uni-chrome plated) (Spacer) OPTIONS

Notes: 1) DP-10□-E-P has a G1/8 male thread. DP-10□-N (-P)has a NPT1/8 male thread. SIMPLE
2) The panel tickness should be 1 to 32 mm 0.039 to 1.260 in. WIRE-SAVING
UNITS

WIRE-SAVING
SYSTEMS
MS-DP1-FM Flat attachment (Optional) MS-DP1-FR/FN/FE Flat attachment (Optional)
MEASURE-
MENT
Assembly dimensions Assembly dimensions SENSORS
Mounting drawing with DP-10□-M(-P) Mounting drawing with DP-10□-M(-P) STATIC
CONTROL
DEVICES

(1.752
44.5
) 37
1.457 ( 2.067
52.5
) 37
LASER
MARKERS
(0.945
24
) 11.5
0.453 (0.945
24
) 1.457
11.5
0.453
PLC
30 11
30 11 1.181 0.433 HUMAN
1.181 0.433 52.5 24 MACHINE
44.5 24 2.067 0.945 INTERFACES
1.752 0.945 6.5 0.256
ENERGY
6.5 0.256 5.5 0.217 13.5 MANAGEMENT
5.5 0.217 0.531 SOLUTIONS
2-ø4.3 ø0.169 20 2-ø4.3 14
0.787 ø0.169 0.551 8.5 FA
17.5 20 Product distinguishing mark COMPONENTS
24 0.787 MS-DP1-FR: 0 line
0.335
0.945 0.689 17.5
24 MS-DP1-FN: 1 line 0.689
30 Material: Polybutylene terephthalate (PBT) 0.945 MACHINE
30 MS-DP1-FE: 2 line VISION
1.181 (Glass fiber reinforced) (Enclosure) 1.181 SYSTEMS
M5 female thread Stainless steel (SUS303) (Pressure port) Pressure port Material: Polybutylene terephthalate (PBT)
Hydrogenated Nitrile Butadiene Rubber (Glass fiber reinforced) (Enclosure) UV
G1/8 female thread (Note) CURING
(H-NBR) (O-ring) Stainless steel (SUS303) (Pressure port) SYSTEMS
Weight: 15 g approx. (flat attachment only) Hydrogenated Nitrile Butadiene Rubber (H-NBR)
(O-ring)
Two M3 (length 8 mm 0.315 in) screws,
8.5 0.335 two M4 (length 20 mm 0.787 in) screws Weight: 25 g approx. (flat attachment only)
are attached. Two M3 (length 8 mm 0.315 in) screws, two M4
(length 20 mm 0.787 in) screws are attached.
Selection
Note: MS-DP1-FR has a Rc1/8 female thread. Guide
MS-DP1-FN has a NPT1/8 female thread. Pressure/
Digital Display
Pressure/
Head-separated
Flow

DP-0
MS-DP1-7 Conversion bushing (Optional) CN-14A(-R)-C□ Connector attached cable (Optional, CN-14A-C2 is attached to the sensor)
DP-100
15.8 DP-M
0.622 L

( 35
1.378 ) ( 50
1.969 )
(0.3158 ) (0.3158 )
14
0.551
3.5 7.8 ø3.7 ø0.146 cable
0.138 0.307 M5 male thread

( 0.5
0.020 ) Gasket
• Length L

11 0.433 10 0.394 8 Model No. Length L (mm in)


0.315
CN-14A(-R)-C1 1,000 39.370
Rc1/8 female thread
CN-14A(-R)-C2 2,000 78.740

Material: Brass (Nickel plated) CN-14A(-R)-C3 3,000 118.110


Weight: 10 g approx.
CN-14A(-R)-C5 5,000 196.850