Sunteți pe pagina 1din 2

SIMATIC puerta automatica\ 21/12/2012 10:56:45

SIMATIC 300(1)\CPU 314 IFM\...\OB1 - <offline>

OB1 - <offline>
""
Nombre: Familia:
Autor: Versión: 0.1
Versión del bloque: 2
Hora y fecha Código: 21/12/2012 10:55:42
Interface: 15/02/1996 16:51:12
Longitud (bloque / código / datos): 00172 00052 00020

Nombre Tipo de datos Dirección Comentario


TEMP 0.0
OB1_EV_CLASS Byte 0.0 Bits 0-3 = 1 (Coming event), Bits 4-7 = 1 (Event class 1)
OB1_SCAN_1 Byte 1.0 1 (Cold restart scan 1 of OB 1), 3 (Scan 2-n of OB 1)
OB1_PRIORITY Byte 2.0 Priority of OB Execution
OB1_OB_NUMBR Byte 3.0 1 (Organization block 1, OB1)
OB1_RESERVED_1 Byte 4.0 Reserved for system
OB1_RESERVED_2 Byte 5.0 Reserved for system
OB1_PREV_CYCLE Int 6.0 Cycle time of previous OB1 scan (milliseconds)
OB1_MIN_CYCLE Int 8.0 Minimum cycle time of OB1 (milliseconds)
OB1_MAX_CYCLE Int 10.0 Maximum cycle time of OB1 (milliseconds)
OB1_DATE_TIME Date_And_Time 12.0 Date and time OB1 started

Bloque: OB1 "Main Program Sweep (Cycle)"

PUERTA AUTOMATICA

Segm.: 1 CONDICIONES ABRIR

U "MANDO" E124.1 -- MANDO SEÑAL


UN "FC_1" E124.2 -- FINAL DE CARRERA 1ABIERTO
U "FC_2" E124.3 -- FINAL DE CARRERA 2 CERRADO
UN "KM1_CERRAR" A124.0 -- CONTACTOR RELÉ CERRAR
= "COND_ABRIR" M0.0 -- CONDICIONES ABRIR

Segm.: 2 CONDICIONES CERRAR

UN "FC_2" E124.3 -- FINAL DE CARRERA 2 CERRADO


U "FC_1" E124.2 -- FINAL DE CARRERA 1ABIERTO
UN "KM2_ABRIR" A124.1 -- CONTACTOR RELÉ ABRIR
= "COND_CERRAR" M0.1 -- CONDICIONES CERRAR

Segm.: 3 CONDICIONES PARO

ON "TÉRMICO" E124.7 -- RELÉ TERMICO


= "COND_PARO" M0.3 -- CONDICIONES PARO

Segm.: 4 FUNCIONAMIENTO ABRIR

U "COND_ABRIR" M0.0 -- CONDICIONES ABRIR


S "COND_ABRIR" M0.0 -- CONDICIONES ABRIR

U "COND_ABRIR" M0.0 -- CONDICIONES ABRIR


S "KM2_ABRIR" A124.1 -- CONTACTOR RELÉ ABRIR

Página 1 de 2
SIMATIC puerta automatica\ 21/12/2012 10:56:45
SIMATIC 300(1)\CPU 314 IFM\...\OB1 - <offline>

U "SENSOR" E124.5 -- SENSOR B1


ON "FC_2" E124.3 -- FINAL DE CARRERA 2 CERRADO
R "KM2_ABRIR" A124.1 -- CONTACTOR RELÉ ABRIR

Segm.: 5 FINCIONAMIENTO CERRAR

U "COND_CERRAR" M0.1 -- CONDICIONES CERRAR


S "COND_CERRAR" M0.1 -- CONDICIONES CERRAR

U "COND_CERRAR" M0.1 -- CONDICIONES CERRAR


S "KM1_CERRAR" A124.0 -- CONTACTOR RELÉ CERRAR

UN "FC_1" E124.2 -- FINAL DE CARRERA 1ABIERTO


O "SENSOR" E124.5 -- SENSOR B1
R "KM1_CERRAR" A124.0 -- CONTACTOR RELÉ CERRAR

Página 2 de 2