BRIDGE NAVIGATIONAL

WATCH ALARM SYSTEM

HBN - 117
The purpose of a bridge navigational watch alarm system(BNWAS) is to monitor bridge
activity and detect operator disability which could lead to marine accidents.
The system monitors the awareness of the officer of the watch(OOW) and automatically
alerts the captain or another qualified OOW if for any reason the OOW becomes incapable
of performing the OOW's duties.
Additionally, the BNWAS may provide the OOW with a means of calling for immediate
assistance if required.
The BNWAS should be operational whenever the ship's heading or track control system
is engaged, unless inhabited by the captain.

HBN - 117
Bridge Navigational Watch Alarm System
TIMER RUN
OFF AUTO

ALARM STAGE FAIL ALARM


BRIDGE VISUAL RST AC POWER

BRIDGE AUDIO DC POWER

OFFICER CALL SYSTEM

CREW CALL
DIMMER / SET
EM'CY CALL RESET MINUTE MIN
RST RST /
(mode) SECOND SEC

OFFICER CREW

System Feature
User-friendly
Dimmer control
Emergency call facility
Timer display
Motion sensor with infrared and microwave detection
Auto-run input(Auto pilot)
Main supply DC24V or AC220V
Alarm (Visual and Audible)
- Standard : 30ea
- Option : Max. 90ea
BRIDGE NAVIGATIONAL
WATCH ALARM SYSTEM
HBN - 117 SYSTEM DIAGRAM
W/H

Motion sensor Motion sensor


(BNP-740) (BNP-710) (BNP-720) (BNP-741)
BNP-710 BNWAS

BNP-720 BNWAS

RESET
RESET

DIMMER

DIMMER

AC
HBN - 117
Bridge Navigational Watch Alarm System Auto pilot
-Option- TIMER
OFF
RUN
AUTO

AC
POWER SUPPLY DC
DC HPS - 100B ALARM STAGE
BRIDGE VISUAL RST
FAIL ALARM
AC POWER
AMS
( 24V,3A )
BRIDGE AUDIO DC POWER

OFFICER CALL SYSTEM

CREW CALL
DIMMER / SET
EM'CY CALL RESET MINUTE MIN
RST RST /
(mode) SECOND SEC

OFFICER CREW

Officer Deck
J.B

BNWAS BNWAS BNWAS BNWAS

Captain C / Officer 2nd / Officer 3rd / Officer

Crew Deck 1 Crew Deck 2


BNWAS BNWAS BNWAS BNWAS

J.B J.B

TIME CHART 90sec 3rd STAGE REMOTE AUDIBLE ALARM


(90~180)
(CREW CALL)
15sec 2nd STAGE REMOTE AUDIBLE ALARM
(OFFICER CALL)
15sec
1st STAGE REMOTE AUDIBLE ALARM
(BRIDGE)
12min VISUAL INDICATOR
(3~12)
(RESET SWITCH FLICKER)
BRIDGE NAVIGATIONAL
WATCH ALARM SYSTEM
HBN - 117 Detail of Devices
Model MAIN (HBN - 117)
Main AC100 ~ 220V
Power Source
HBN - 117 Em'cy DC24V
Bridge Navigational Watch Alarm System
TIMER RUN
Consumption Max. 1.2A
OFF AUTO

W/H In / Output Max. 4 port (Reset, Visual, Audible Alarm)


Officer Output Max. 2 port
ALARM STAGE FAIL ALARM
Crew Output Max. 2 port
BRIDGE VISUAL
BRIDGE AUDIO
RST AC POWER
DC POWER
Motion Sensor Max. 2 port
Max. 4 port (Normal Open or Normal Close, $--HTD)
SYSTEM

Auto Run
OFFICER CALL
CREW CALL
DIMMER / SET
EM'CY CALL
RST
RESET
(mode)
RST
MINUTE
SECOND
MIN
/
SEC
Fault Output Max. 2 port (Normal Open or Normal Close)
OFFICER CREW NMEA Output $BNALR (IEC-61162-1, RS-422 / 4,800bps or 38,400bps)
Wall type W270 X H188 X D110, 3kg
Dimension / Weight
Desk type W210 X H145 X D105, 2kg

MODEL BNP - 710F BNP - 720F BNP - 730F BNP - 750A/R (IP65)

BNP-710 BNWAS
BNWAS BNWAS

BNP-720 BNWAS

ALARM UNIT RESET


RESET

DIMMER DIMMER

DISCRIPTION Reset,Visual Alarm Reset,Visual,Audible Alarm Audible Alarm Reset,Visual,Audible Alarm


POWER SOURCE DC24V, Max 20mA DC24V, Max 70mA DC24V, Max 30mA DC24V, Max 30mA / Max 15mA
SOUND LEVEL 85dB/m,var.volume & tone 85dB/m 85dB/m
DIMENSION 80W X 120H X 70D 120W X 80H X 70D 80W X 80H X 57D 80W X 80H X 73D / 25
WEIGHT 0.5kg 0.5kg 0.1kg 0.2kg / 0.15kg

MODEL BNP - 710 BNP - 720 BNP - 730

BNW
AS

ALARM UNIT

DISCRIPTION Reset,Visual Alarm Reset,Visual,Audible Alarm Audible Alarm


POWER SOURCE DC24V, Max 20mA DC24V, Max 70mA DC24V, Max 30mA
SOUND LEVEL 85dB/m, var. vol & tone 85 dB/m
DIMENSION 80W X 120H X 80D 120W X 80H X 80D 80W X 80H X 58.7D
WEIGHT 0.8kg 0.8kg 0.15kg