Sunteți pe pagina 1din 5

STANDARD No.

ei ENGINEERS STORAGE TANK STEAM COIL


Rateg INDIA LIMITED 7-13-0004 Rev. 7
li1R7f efernted51J,
141,41) IA Goal of India Undertaking) (TANK DIA...5M)
Page 1 of 5

0
0
fn 0
Lc"

SECTION A—A

-SUPPORT
TYPE-1

SUPPORT
TYPE-3

TANK DIA.

(IA)

7 01.10.2013 REAFFIRMED AND REISSUED AS STANDARD GCP(.<.e.)- "gliT SC

6 27.01.2009 REAFFIRMED AND REISSUED AS STANDARD VPR RKG AKM VC

Prepared Checked Stds. Committee Stds. Bureau


Rev.
Date Purpose Convenor Chairman
No. by by
Approved by
Format No R-00-0001-F4 RPV Convrinht Fll - All rinhts rpsprvpri
STANDARD No.
t31 ENGINEERS STORAGE TANK STEAM COIL
fzgal fCGS INDIA LIMITED 7-13-0004 Rev. 7
+REM efeantranXritRit (A Govt of India Undertaking) (TANK DIA. > 5M TO 15M)
Page 2 of 5

/■/
IN

OU To
o

SECTION A-A

TANK I.D.

0 r
0
IN c■S 0

A
OUT 0
0

SUPPORT
TYPE-1 (TYP.)

SUPPORT
TYPE-3 (TYP.)

N14
7 01.10.2013 REAFFIRMED AND REISSUED AS STANDARD CCP( ik'Kr SC

6 27.01.2009 REAFFIRMED AND REISSUED AS STANDARD VPR RKG AKM VC

Prepared Checked Stds. Committee Stds. Bureau


Rev.
Date Purpose Convenor Chairman
No. by by
Approved by
Frwmat Nn 9-nn-0081-F4 RPV n r.nnvrinht Fll - All rinhts rARprvpri
STANDARD No.
ei ENGINEERS STORAGE TANK STEAM COIL
Oar W5 INDIA LIMITED 7-13-0004 Rev. 7
wreer zreav? 00351050) IA Govt of India Undertaking) (TANK DIA. > 15M TO 50M)
Page 3 of 5

IN

OUT

SECTION A-A

TANK I.D.

SUPPORT'
TYPE-2
(TYP.)

SUPPORT
TYPE-3 (TYP.)

DIA. OF TANK DIMENSIONS


(M) A B
15.1 TO 20 250 500
20.1 TO 35 300 600
35.1 TO 50 550 700

7 01.10.2013 REAFFIRMED AND REISSUED AS STANDARD GCPL4, TK SC


6 27.01.2009 REAFFIRMED AND REISSUED AS STANDARD VPR RKG AKM vc
Prepared Checked Stds. Committee Stds. Bureau
Rev.
Date Purpose Convenor Chairman
No. by by
Approved by
Frwmat Not 8-00-0001-F4 Rev n Cnnvrinht Fll - All rinhts reserver)
STANDARD No.
ENGINEERS STORAGE TANK STEAM COIL
INDIA LIMITED 7-13-0004 Rev. 7
144727f ektavenstarfds.0 (A Govt of India Undertaking) (TANK DIA. > 50M)
Page 4 of 5

IN

0
0 00
OUT,.
co 0
0 0

SECTION A-A

TANK I.D.

T.

\-/ \_1 \_/ \-1 \-1

N /-\ I1
/I /"'s /-*\
II
II
)

)
SUPPORT
TYPE-2 (TYP.)

SUPPORT

2000 2000
[TYPE-3 (TYP.)

zt

REAFFIRMED AND REISSUED AS STANDARD GCP Wcr SC


7 01.10.2013
REAFFIRMED AND REISSUED AS STANDARD VPR RKG AKM VC
6 27.01.2009
Prepared Checked Stds. Committee Stds. Bureau
Rev.
Date Purpose Convenor Chairman
No. by by
Approved by
Fru-mat Nn a-nn-nnn1-F4 RPV n Cnnvrinht Fll - All rinhts resprvpri
STANDARD No.
ENGINEERS STORAGE TANK STEAM COIL
1i fatZs INDIA LIMITED 7-13-0004 Rev. 7
1.17e7f 212215T22151370.1) IA Govt of India Undertaking) (SUPPORTS AND GENERAL NOTES)
Page 5 of 5

'ye

14 I
SUPPORT L50x50x6THK 410
©1500 mm SPACING

TYPE - 1 TYPE - 2
M12 U BOLT
WITH DOUBLE
NUTS (TYP.)
(MATERIAL SPEC.
6THK. IS:1363)
PLATE

DO NOT WELD
0 WITH TANK
o
BOTTOM
75 FOR 40 NB
85 FOR 50 NB
105 FOR 80 NB

DETAIL c DETAIL - D TYPE - 3


NOTES:
1. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED.
2. ALL FILLET WELDS SHALL BE 6mm UNLESS OTHERWISE SHOWN.
3. STEAM INLET AND OUTLET NOZZLES SHALL PREFERABLY BE LOCATED NEAR THE LIQUID OUTLET NOZZLE.
4. TANK FABRICATOR TO ENSURE THAT THE STEAM COIL AND COIL SUPPORTS DO NOT FOUL WITH INTERNALS LIKE
(i) GAUGE HATCH AND LEVEL INDICATOR DIPPING AREA (APPROX. 500mm DIA.)
(ii) FLOATING ROOF LEG SUPPORTS (APPROX. 500mm 01k)
(iii) ROOF DRAIN/EMERGENCY DRAIN/SIPHON DRAIN.
(iv) AGITATOR MIXER
(v) SKIMMING DEVICE.
5. AFTER HYDROTEST OF THE TANK THE HEIGHT OF ALL SUPPORTS SHALL BE READJUSTED TO TAKE CARE OF UNEVEN
SETTLEMENT OF TANK BOTTOM BY USING PACKING PLATE FULLY WELDED TO SUPPORT BASE PLATE OR BY READJUSTING
THE SUPPORTS HEIGHT.
6. FOR MATERIAL SPECIFICATION, DESIGN DATA AND ACTUAL LENGTH OF COIL REQUIRED REFER ENGINEERING DRAWING.
7. THIS STANDARD IS FOR GENERAL GUIDANCE. BASED ON REQUIRED LENGTH OF COIL SHOWN ON ENGINEERING DRAWING,
SELECT AND WORK OUT A SUITABLE LAYOUT ENSURING UNIFORM HEATING OF PRODUCT STORED.
8. PIPE MAY BE BENT TO A MINIMUM RADIUS EQUAL TO THREE TIMES THE DIAMETER. BEND SHALL BE FREE OF CRACKS
AND BUCKLES. FLATTENING OF A BEND, AS MEASURED BY THE DIFFERENCE BETWEEN THE MAXIMUM AND MINIMUM
DIAMETER AT ANY CROSS SECTION SHALL NOT EXCEED 8% OF THE NOMINAL OUTSIDE DIAMETER.
9. HEATING COIL SHALL SLOPE TOWARDS OUTLET NOZZLE FOR SELF DRAINAGE.
10. MAXIMUM UNSUPPORTED LENGTH OF STEAM COIL SHALL BE AS PER THE FOLLOWING TABLE.

NOMINAL DIA. OF PIPE 40 50 80


MAXIMUM UNSUPPORTED LENGTH 4000 5000 6500

11. UNLESS OTHERWISE STATED IN ENGINEERING DRAWING ALL INTERNAL BOLTSSHALL BE STAINLESS ST
s' r;
7 01.10.2013 REAFFIRMED AND REISSUED AS STANDARD GCP Rrr SC

6 27.01.2009 REAFFIRMED AND REISSUED AS STANDARD VPR RKG AKM VC


Prepared Checked Stds. Committee Stds. Bureau
Rev.
Date Purpose Convenor Chairman
No. by by
Approved by
Format No FI-00-0001-F4 RPV Convrinht Fll - All nnhts rpsprvpil