Sunteți pe pagina 1din 12

Deman HVAC & Green Building Products

doc# ProductsQ00

MM1..A16 Fan coil controller 02

MM1..A20 Fan coil controller 03

MM1..A30 Fan coil controller 04

MMD Diffuser control 05

MMT Diffuser control (high slave count) 06

M1 range Modular HVAC controller 07

MK range User interface (wall) units 08

Alux range Lighting & HVAC control products 09

Doc. Deman data sheets 11

01
HVAC & Green Building Products ProductsQ00
MM1..A16 Fan Coil Controller

Description Standard FCU controller. Thermic valve, 3 speed fan and single heating element

Product code: MM1-A16 -- stand alone


MM1LA16 -- LON
MM1BA16 -- BACnet
MM1SA16 -- local seri net

Peripherals: MK2A24 -- wall unit (portrait)


MK4A14 -- wall unit (landscape)
NTC10HB1 -- Temperature sensor

230V AC
Controller I/O

LON, BACnet 3 speed


or Seri port fan

wall unit
thermic
valve
return air temp.

discharge air temp. heater


element
shut down interlock
power in
occupancy

Data sheet # MM1xQ11

02
HVAC & Green Building Products ProductsQ00
MM1..A20 Fan Coil Controller

Description Standard FCU controller. Thermic valve, 3 speed fan and 12V control out to solid state
relay switching the heater element. (Proportional heating control.)

Product code: MM1-A20 -- stand alone


MM1LA20 -- LON
MM1BA20 -- BACnet
MM1SA20 -- local seri net

Peripherals: MK2A24 -- wall unit (portrait)


MK4A14 -- wall unit (landscape)
NTC10HB1 -- Temperature sensor
MT1A12 -- Solid state relay

230V AC
Controller I/O

LON, BACnet 3 speed


or Seri port fan

wall unit
thermic
valve
return air temp.

discharge air temp.


230V AC
shut down interlock

12v control to
occupancy solid state relay

Data sheet # MM1xQ20

03
HVAC & Green Building Products ProductsQ00
MM1..A30 Fan Coil Controller

Description Standard FCU controller. Thermic valve, 0-10V fan control and single heating element.

Product code: MM1-A30 -- stand alone


MM1LA30 -- LON
MM1BA30 -- BACnet
MM1SA30 -- local seri net

Peripherals: MK2A24 -- wall unit (portrait)


MK4A14 -- wall unit (landscape)
NTC10HB1 -- Temperature sensor

Controller I/O
0-10V to Fan
LON, BACnet
or Seri port
relay out
wall unit
thermic
return air temp. valve
discharge air temp.
heater
element
shut down interlock

power in
occupancy

230V AC

Data sheet # MM1xQ30

04
HVAC & Green Building Products ProductsQ00
MMD Diffuser Control

Description Diffuser master with one slave unit per diffuser. Maximum of 3 slaves per control output.
A total of 6 slaves. Slaves are for damper only or for damper plus heating element.

Product code master unit: MMDM-A12 -- stand alone


MMDMLA12 -- LON
MMDMBA12 -- BACnet
MMDMSA12 -- local seri net

Product code slave units: MMDSA11 -- damper only


MMDSA21 -- damper + heater element

Peripherals: MK2A81 -- wall unit 3 button (portrait)


MK4A20 -- wall unit 3 button (landscape)
NTC10HB1 -- Temperature sensor
SDVDSH10 -- Interconnect cable (3m)
SDVDSH20 -- Interconnect cable (6m)

Master I/O
LON, BACnet
or Seri port

wall unit

room temp. 24V AC

supply air temp.


slave control
3 max.
interlock
slave control
occupancy MMDM... 3 max

damper damper
Slaves I/O heater
MMDSA21 MMDSA11

230V~

control in/out control in/out

Data sheet # MMDxQ30

05
HVAC & Green Building Products ProductsQ00
MMT Diffuser Control (high slave count)

Description Diffuser master with one slave unit per diffuser. Maximum of 8 slaves per control
output. A total of 16 slaves (diffusers). Slaves are for damper only or for damper plus
heating element.

Product code master unit: MMTM-A10 -- stand alone


MMTMLA10 -- LON
MMTMBA10 -- BACnet
MMTMSA10 -- local seri net

Product code slave units: MMTSA10 -- damper only


MMTSA20 -- damper + heater element

Peripherals: MK2A81 -- wall unit 3 button (portrait)


MK4A20 -- wall unit 3 button (landscape)
NTC10HB1 -- Temperature sensor
SDVDSH10 -- Interconnect cable (3m)
SDVDSH20 -- Interconnect cable (6m)

Master I/O

LON, BACnet
or Seri port

wall unit

room temp. 24V AC

supply air temp.


slave control
8 max.
interlock
slave control
occupancy MMTM... 8 max

damper damper
Slaves I/O heater
MMTSA20 MMTSA10

230V~

control in/out control in/out


Data sheet # MMTxQ10

06
HVAC & Green Building Products ProductsQ00
M1 modular HVAC controller

Description HVAC controller with 4 plug in control and/or I/O modules. Modules and functionality to
be specified as per the application.

Product code: M1B... as allocated during assembly

Peripherals: MK2A24 -- wall unit 5 button (portrait)


MK4A14 -- wall unit 5 button (landscape)
NTC10HB1 -- Temperature sensor

1 step on/off
3 step on/off 1 step on/off
Phase contr. 3 step on/off
PWM PWM
0-10V 0-10V

Controller I/O
fan heat

discrete I/O
analog in

valve /
general damper

230V~ in
LON, BACnet

temp. 1

temp. 2

wall unit

interlock
or Seri port

1x or 2x

Float
On / Off
PWM
0-10V
Data sheet # M1xQ10

07
HVAC & Green Building Products ProductsQ00
MK user interface (wall) unit

Description Wall mounted user interface for Deman HVAC controllers. Two wire polarity insensitive
connection to the controller. The controller is usually situated at or near the FCU or
HVAC device being controlled.

Product code: MK2A24 -- 5 button portrait (on/off, temp. and fan)


MK2A52 -- 2 button portrait (temp. only)
MK2A81 -- 3 button portrait (on/off and temp.)

MK4A14 -- 5 button portrait (on/off, temp. and fan)


MK4A20 -- 3 button portrait (on/off and temp.)

User interface for: MM1, MMD, MMT and M1 range of controllers.

Interface unit
(portrait)
F
C
SP

Interface unit
(landscape)
SP A
C

Data sheet # MK2Q10

08
HVAC & Green Building Products ProductsQ00
Alux lighting and HVAC control

Description Master unit with occupancy sensor input controlling up to 16 slave relays. One slave
relay per switching point or device to be switched. A switching point can be a light
fitting, a HVAC device or other.

Product code: AluxM6A10 -- master unit


AluxM7A10 -- mikro master

AluxS1A11 -- inline light slave unit. 3A max


AluxS2A10 -- high current slave unit. 12A max
AluxS3A10 -- HVAC signal slave unit
AluxS4A10 -- plug socket light slave unit. 3A max

CL-1806 -- ceiling occupancy sensor (7m dia)


IS25100TC -- corridor sensor (2m x 25m)

230V~
230V~ 230V~
8 max
Wiring schematic
master

slave

slave

control
8 max device device

occupancy
sensor

Master - AluxM6 slave out 8 slaves max


230V~ slave out 8 slaves max
occup.in occupancy sensor
M6 config.

configuration
setting

09
HVAC & Green Building Products ProductsQ00
Alux lighting and HVAC control (continue)

Micro master - AluxM7


230V~ M7 slave out 8 slaves max
occup.in occupancy sensor
230V~ power out
config.
12A max configuration
setting

occupancy sensor connecting cable


Sensor - AluxI2
I2

Slave - AluxS1 230V~ S1 light fitting (3A max)

control I/O

Slave - AluxS2
230V~
S2 control I/O
230V~
15A max

Slave - AluxS3 S3 V free signal contact


for HVAC control

control I/O

Slave - AluxS4 light fitting 230V~

I/O
tr ol
con
Data sheet # AluxQ20

10
HVAC & Green Building Products ProductsQ00
Deman data sheets

Alux AluxQ20 Lighting and HVAC control

LON CAT5-1LQ10 LONWORKS Bus Wiring Guidlines

LONTKQ10 LONWORKS Network Wiring Aid

M1 M1xQ10 Modular HVAC Controller

MK2 MK2Q10 Wall Unit (User Interface)

MK2Q21 Wall Unit: Setting the Temperature Offset

Mk2Q30 Wall Unit: Additional Diagnosti Functions

MK2Q60 Wall Unit: 5 Button Input Protected Unit

MM1 MM1BACQ10 MM1 range BACnet Interface

MM1BACQ20 Basic MM1 BACnet Device Info

MM1xQ11 MM1 Fan-coil Controller

MMD MMDBACQ10 MMD range BACnet Interface

MMDBACQ20 Basic MMD BACnet Device Info

MMDxQ10 MMD Diffuser Control

MMT MMTxQ10 MMT Diffuser Control

SDV SDVBACQ10 SDV range BACnet Interface

SDVBACQ20 Basic SDV BACnet Device Info

SDVxQ10 SDV HVAC Controller

Note: Data not available at www.deman.co.za will be forwarded on request.

11
HVAC & Green Building Products ProductsQ00
www.deman.co.za

Deman Manufacturing (Pty)Ltd

10 Steenbok Street POBox 26208 tel +27 12 403 8000


Koedoespoort Gezina
0186 0031 fax +27 12 333 3371
Pretoria Pretoria
South Africa South Africa www.deman.co.za