Sunteți pe pagina 1din 1

Please Note: Each project and its site conditions are unique.

An architect, landscape architect and/or structural engineer should be consulted to develop a specification suited for the specific project. The component
suggestions in these drawings are only an illustration and are not intended to be project specific. Each application and specification should have the attention of an architect, landscape architect and/or structural engineer.
As project use and site conditions are not within Hanover's control, Hanover does not guarantee results from use of such products or other information. Hanover makes no representations or warranties, either express or
implied, as to the suitability of the drawings for any specific purpose. Hanover is providing these drawings solely for the purpose of assisting with estimating quantities and layout and is not responsible for shortages,
overages, accuracy of dimensions or engineering of any kind. Hanover shall not be responsible for any liability that may arise or result from the use of the drawings by the customer, its officers, employees, agents,
contractors and/or subcontractors. Hanover assumes no responsibility for field conditions, elevation changes or any other factors that may impact final pedestal count. The customer is responsible for coordination of
updates. Hanover is not responsible to any users of the drawings for updating or for compatibility with the user's hardware or software. The user is responsible for examining the drawings for virus contamination, prior to
use thereof.

Layout Assistant is a complimentary one time service to help assist you in accurate counts of pavers and/or pedestals. Please note that Layout Assistant can only be as accurate as information provided. All other revisions
to either layout or information provided can be added and changed to takeoff at an additional set hourly fee. CONNOR MILLER
Roof area and Pedestal quantities have been established from the following architect supplied information:
- PDF's supplied on 8/5/2020- La Central 2nd Floor roof area Mountco 8-3-20.pdf, La Central A L-103.pdf, La Central A L-102.pdf, and La Central A L-104.pdf.
- Layout assistant was asked to help provide a layout for this project for nominal sized 2'x2' pavers. The PDF's that were supplied were portions of the roof plan that had to be matched and merged into one roof plan
STARTING POINT which shows the entirety of the roof terrace. Different areas were shown, but no starting points for the paver layouts were given. Since the roof plan had to be converged into one drawing, layout assistant does not
gurarntee that the plan is matched perfectly. Since all of the files that were submitted were PDF's some of the lines along the match line were distorted which made it difficult to properly merge. The outline of the
roof terrace may vary to an as-built condition, which would then affect the paver quantities and pedestals listed on this page. Hanover does not guarantee that the quantities listed will be accurate.
- No information regarding the slope of the roof, drain locations, or threshold heights were given at the time the layout assist was completed. Therefore, only points of contact quantities were able to be determined for
this project. This drawing does contain areas around the perimeter that requires small cut pieces that may prove difficult to properly support on Hanover's pedestal systems. Other means of properly supporting
those cut pieces may need to be used in order to achieve this layout design.
- Hanover® requires that all perimeters of pavers be contained or restrained as part of elevated paver system requirements.
- Hanover® has used the following nominal paver sizes to assist in takeoff:
-- 23-1/2" x 23-1/2" x 2"
-- 23-1/2" x 35-3/8" x 2" (oversized with scored line at 23-1/2")
- Pedestal placement may need to be adjusted due to paver cuts and modifications in field. Therefore, pedestal counts may be incorrect. Please note that in areas such as perimeters where the pavers will be cut,
adhesive may need to be placed to hold paver to pedestal. Hanover® suggests using 3M Scotch-Weld™ Structural Plastic Adhesive DP 8005 Black to adhere pavers to pedestals.
- Please note that layout is designed with full paver per spot quantity. Full paver may not be needed at all spots so paver count may be inaccurate.
- Hanover® requires a minimum of 60 PSI insulation under the elevated pedestal system.

LA CENTRAL - BUILDING A
- After phone conversations and file exchange, no starting point was given. Therefore, Layout Assistant has marked starting point on drawing. If this starting point is not utilized when starting the paver layout, these
quantities may be inaccurate because of the use of oversized pavers.

Enlarging, reducing, and modifying PDF's and DWG's will impact the scale. Therefore an exact measurement is not guaranteed.
STARTING POINT

Please note this is a layout assistant. We assume no responsibility for field conditions, elevations changes or any other factors that may impact final pedestal count. All pedestals are sold in full box quantities.

Total Quantities: STARTING POINT

Hanover® Prest® Paver Oversized Prest® Paver Points of Contact


(23-1/2" x 23-1/2" x 2") (23-1/2" x 35-3/8" x 2") with false joint

Quantity: 2,765 EA Quantity: 340 EA Quantity: 3,855 EA LOCATION: BRONX, NY

23-1/2" 35-3/8" DATE: 8/6/2020 SCALE: 1"=1'


DETAILED: CONNOR MILLER
23-1/2" 23-1/2" D 7-3/8"
DRAWING: 1 OF 1
*DRAWINGS ARE FOR PORTFOLIO USE ONLY
AND SHOULD NOT BE COPIED, DUPLICATED,
REUSED, OR SHARED WITHOUT THE
STARTING POINT
PERMISSION OF THE OWNER
NOTE: IT IS CRITICAL THAT TOP UNITS AND
COUPLERS HAVE A MINIMUM INSERTION
OF THREE THREADS OF THE UNIT TO
4" TOP
SERVICE: ASSISTANT
* 1/16" and 1/8" Leveling Plates available COMPLETLY SECURE THE PEDESTAL
to accommodate different heights when AND ENSURE STABILITY. *LENGTH AND WIDTH DIMENSIONS ARE
utilizing the High Tab Pedestals COUPLER
MADE WITH A TOLERANCE OF +/- 81".
4" TOP
4" TOP

*THICKNESS AND HEIGHT DIMENSIONS ARE


COUPLER COUPLER COMPENSATOR®
3" TOP
4" TOP
COUPLER MADE WITH A TOLERANCE OF +/- 81".
2" TOP
4" BASE 4" BASE *1/8" PER FOOT SLOPE *DIMENSIONS SHOWN ARE NOMINAL.
2" BASE 3" BASE 4" BASE 3" BASE
*POINT NOTCH 1 TOWARDS PRODUCTS ARE MADE TO FIT METRIC
3/8" 5/8" 1-1/4" 1-7/8" 2" - 3" 3" - 4 ¾" 4 ¾" - 7 ¾" 7 ¾" -10" 9" - 12" 12" - 16" ** HIGH POINT OF SLOPE
MODULES.
** THE USE OF ADDITIONAL COUPLERS WILL ATTAIN HEIGHTS UP TO 24".
HEIGHTS OF 16" TO 24" REQUIRE SPECIAL BRACING INSTALLATION DETAILS. UNLESS OTHERWISE NOTED:
*JOINTS ARE MADE TO AN 1/8"