Sunteți pe pagina 1din 3

Validation of MODICON 3-2 Receiver Board Operation

Receiver Setup Procedure

 Set up the MODICOM 3/1 transmitter (see separate help document for detailed instructions)

 Connect the power supplies to the MODICOM 3/2 receiver as shown below

IC POWER 60
+12V
5V, 1A
0V

-12V

+5V 0V +12V 0V -12V +5V 0V +12V 0V -12V


MODICOM 3/1 MODICOM 3/2

MODICOM 3/1 and MODICOM 3/2 Power Connections

 Ensure that the following initial conditions exist on the MODICOM 3/2 Receiver board:

a) MODE switch in FAST position


b) SYNC. CODE DETECTOR 'on/off' switch in OFF position
c) ERROR CHECK CODE SELECTOR switches to 'off' (A=0, B=0)
d) All four SWITCHED FAULTS to OFF position
e) PULSE GENERATOR DELAY ADJUST control fully clockwise

MODICOM 3/2
P.C.M. RECEIVER
CLOCK GENERATION CIRCUIT
2

SYNC CODE DETECTOR


37 SYNC
OFF BIT
VCO
COUNTER
FREQUENCY 44
ADJUST ON

0V 38 39 40 41 42 SYNC
43 ERROR
COUNTER 45
PULSE +5V
GENERATOR OUTPUT

4 RX.CLOCK INPUT RECEIVER TIMING LOGIC


6 7 8 MODE
DELAY ADJUST VCO FAST
46
5
INPUT 3 RX.SYNC INPUT SLOW
RX.TO
0V 47 48

ERROR CHECK CODE SELECTOR SWITCHED FAULTS


AB MODE
00 OFF 1
OFF
01 EVEN PARITY
10 ODD PARITY
0 ON
11 HAMMING 1 2 3 4
A B

MODICOM 3/2 Initial Conditions


The MODICOM 3/1 transmitter and MODICOM 3/2 receiver are now set up for
correct operation.

 On the MODICOM 3/1 board, connect:

1kHz output to CH0 input


2kHz output to CH1 input

 Connect MODICOM 3/1 to MODICOM 3/2 as shown in Table below

MODICOM 3/1 (Transmitter) MODICOM 3/2 (Receiver)


TX Clock Output RX Clock Input
TX T0 Output RX SYNC Input
TX DATA Output RX DATA Input

 Turn on the power supply.

 Observe the display on the oscilloscope at the following test points on


MODICOM 3/1:

Transmitter CH0 (1kHz) at test point 10


Transmitter CH1 (2kHz) at test point 12

CH.0
CH.0 SAMPLE
5
0V
10 11
+1

0V

CH.1

12 13
+1
0V

Test Points 10 and 12

 Display the transmitter CH0 input (tp10) on oscilloscope channel 1, and use
this channel to trigger the oscilloscope.

Display transmitter TX Data Output (tp44) on channel 2 of the


oscilloscope.

This clearly shows the data stream being sent from the transmitter to the
receiver.

 Vary the 1kHz and 2kHz amplitude controls (in the transmitter Function
Generator block) and note that the transmitted data varies.
 Display the receiver CH0 and CH1 outputs (tp33 and tp36 on MODICOM
3/2 -see Figure 45).

 Check that the two sinewaves have been successfully sent from the transmitter
to the receiver, and that each appears on the correct output channel.

CH.0
31 32 33
+1
SAMPLE/
HOLD
AMPLIFIERS
CH.1
34 35 36
+1

0V

Test Points 33 and 36

 Vary the 1kHz and 2kHz amplitude controls on the transmitter, and observe
the effect on the receiver outputs.

This verifies that the MODICOM 3/2 receiver board is working correctly.