Sunteți pe pagina 1din 18

GE

Voluson E8 BT19
Data Sheet

Product description
The Voluson* E8 BT19 is an advanced imaging platform that
combines extraordinary image quality with our superb volume
ultrasound technology.

Highlights
• High Resolution 23” LCD LED Display
• Based on the Radiance System Architecture
• Advanced 4D
• HDlive* Silhouette
• HDlive* Studio
• HDlive* Flow and HDlive* Flow Silhouette
• Advanced VCI
• SonoBiometry
• SonoAVC*follicle
• SonoVCAD*heart
• Advanced STIC
• Steerable CW
• fetalHQ
• Anatomical M-Mode
• Wide Sector
• Coded Contrast Imaging†
• Scan Assistant
• SonoNT*
• SonoIT
• Compression & Shearwave Elastography
• Elastography Analysis
• Elastography Ratio Measurement
• B-Flow*
• Radiantflow
• SlowFlowHD
• SonoRenderlive
• Electronic Height Adjustment
• Floating User Interface
• On Board Archive including Preview and Pre-selection

Voluson E8 BT19 Datasheet Page 1 of 18


General Specifications System Overview
Dimensions and weight Exam types
Height (minimum) 1330 mm (52.4 in) Abdominal
Height (maximum) 1670 mm (65.7 in) Obstetrical
Adjustable with electrical motor Gynecological
Width 580 mm (22.8 in) Small Parts and Breast
Depth 940 mm (37.0 in) Vascular
Weight (no Peripherals) 147 kg (324.1 lbs.) Pediatrics
Transrectal
Power supply Cardiology
Voltage 100 – 240 VAC Cephalic
Frequency 50/60 Hz (+/-1%) Musculoskeletal (MSK)
Max. 800 VA
Including all options Operating modes
Power
typical power consumption
Brightness Mode (B-Mode) (2D)
~350VA without peripherals
Motion Mode – M-Mode (conventional M-Mode)
Thermal Output max. 2730 BTU/h
Anatomical M-Mode (AMM)
Console design Pulsed Wave Doppler (PW) with HPRF
4 Active and Imaging Probe Ports Continuous Wave Doppler imaging (CW)
Integrated HDD 1 TB Color Flow Doppler mode (CFM)
Operating System: Windows** 10 Iot Enterprise 64 bit Power Doppler Mode (PD)
Integrated DVD+R(W)/CD-R(W) drive High Definition Power Doppler (HD-Flow*)
On-board storage for Peripherals Tissue Doppler Mode (TD) and PW-Tissue Doppler Mode
Wheels Wheel diameter 150 mm B-Flow (BF)
Integrated cable management Compression & Shearwave Elastography (May not be available in
all countries)
Front and rear handles
Contrast Imaging Mode†
Probe port illumination
Combination modes: M/CFM, M/HD-Flow, M/TD, PW/CFM,
PW/HD-Flow, PW/PD, PW/TD
User Interface Extended View (XTD View)
Operator keyboard
Volume Mode (3D/4D):
Floating Keyboard: • 3D Static
• Rotation: adjustable +/- 38° from center • 4D Real Time
• Height adjustable + 195 mm (7.9”) • VCI-A
Full-sized, backlit alphanumeric keyboard • VCI-OmniView
Ergonomic hard key layout • Spatio-Temporal Image Correlation (STIC)
Interactive back-lighting • 4D Biopsy
Integrated recording keys for remote control of up to 6
peripherals or DICOM® devices, one dedicated DVD recording Scanning methods
key Electronic Sector/Convex/Linear
Mechanic Volume Sweep
Touch screen
12.1” high resolution color LCD screen User Management and Logging Functionality
Multi touch interactive dynamic software menu Multiple Users with individual log on credentials
Brightness adjustable Different and adjustable access levels
LDAP Interface
Monitor Enhanced Audit Trail and Usage Log
23” high resolution LCD LED Display with DVI interface
Resolution Full HD 1920 x 1080 pixel Privacy and Security Functionality
Display brightness up to 300 cd/m² Hard disc AES Encryption with 256-bit length
Tilt/Rotate Adjustable Monitor Whitelisting
Tilt angle: min. +30°/-75° Encrypted DICOM Communication Capability (TLS)
Horizontal rotate angle: +/- 90° Encryption and Data Anonymization Export Capability
Digital brightness and contrast adjustment. Five default settings All ports, services and shared resources that are not required for
available: Extra Dark, Dark-, Semi Dark-, Light-, Extra Light Room, the intended use are disabled
each for higher and lower color temperature Operating System Access disabled
Deactivation of USB ports possible

Voluson E8 BT19 Datasheet Page 2 of 18


Inversion Mode
Transducer types Real-time automatic Doppler calculations
Sector Array Measurement, Calculations and Worksheets/Report for:
Convex Array • OB • Small Parts
Microconvex Array • GYN • Transrectal
Linear Array • Vascular • Pediatrics
Active Matrix Linear Array (1.5D) • Cardio • Cephalic
• Abdominal • Musculoskeletal (MSK)
Volume probes 4D:
• Convex Array Multigestational Calculations
• Microconvex Array Integrated uplink for Cloud-based data storage (TricefyTM) (not
• Linear Array available in all countries)
GYN IOTA LR2, Simple Rules and ADNEX Model. (not available in
System standard features all countries)
Innovative user interface with high resolution 12.1” LCD touch GYN IETA Protocol & Report (May not be available in all countries)
panel xTouch
B-Mode
M-Mode System options
PW-Doppler Advanced 4D
CFM (Color Flow Doppler Mode) HDlive Studio, HDlive Flow Silhouette
Automatic Tissue Optimization VOCAL II
Auto TGC Advanced VCI (Volume Contrast Imaging)
Coded Harmonic Imaging with Pulse Inversion Technology SonoVCADlabor
Coded Excitation (CE) Compression Elastography
HD-Flow & Power Doppler Mode Shearwave Elastrography (not available in all countries)
B-Flow Advanced STIC:
Tissue Doppler and PW-Tissue Doppler • Basic STIC • STICflow
XTD • STIC M-Mode • SonoVCADheart
SRI II (Speckle Reduction Imaging) SonoAVC, including SonoAVC follicle, antral and general
Steerable CW Mode
HDlive Silhouette, HDlive Flow
Anatomical M-Mode (AMM)
CrossXBeamCRI*(Compound Resolution Imaging)
Coded Contrast Imaging + 3D HyCoSy†
SonoBiometry (HC, BPD, AC, FL, HL, SonoNT & SonoIT)
Integrated Software DVR
SonoCNS (May not be available in all countries)
• Digital recording
SonoRenderlive • One drive for data export and recording
Scan Assistant: • DVD Formats: DVD+R, -R, +RW, -RW for recording, DVD and CD
• Includes measurements, annotations and fetal anatomy and support for data export
gynecology worksheet entries • USB support: FAT32 compatibility
• Performs predefined mode changes, preset selection and Advanced Security Features
screen layout changes fetalHQ (including speckle tracking capabilities)
• Supports display of user selected reference images Radiantflow, & SlowFlowHD
• Standardize image sequence upon DICOM transfer
• GYN IDEA Guidelines
Peripheral options
DICOM 3.0 Connectivity
Integrated printers: B&W, Color Thermal Printer
Static 3D Mode:
External Color desktop printer with network printing capabilities
• B Mode only
& connection kits
• B + Power Doppler Mode • B + CRI + CFM
• B + CFM Doppler Mode • B + CRI + PD ECG Digital Module
• B + HD-Flow Mode • B + CRI + HD-Flow Foot Switch, with programmable functionality
• B + CRI • B + B-Flow Barcode Scanner
Focus and Frequency Composite (FFC) Magnetic Card reader (not available in all countries)
HD Zoom & Pan Zoom UPS – Uninterruptible Power Supply
Steering Power Filter
Virtual Convex External Patient Monitor Set
Wide Sector Isolation Transformer
Beta-View WLAN Adapter
Patient information database USB Microphone
Image Archive on hard drive
3D/4D data compression (lossy/lossless) Display modes
Simultaneous capability in combination with SRI and/or CRI:

Voluson E8 BT19 Datasheet Page 3 of 18


• B+PW Depth Scale
• B+SRI/STIC+SRI
• B+CFM, B+PD, B+TD Focal Zone Marker
• B+CRI+SRI/STIC+CRI+SRI
• B+HD-Flow Frame Rate
• B/B+CRI
• B+M, B+AMM
• B/B+SRI Zoom Start/Depth
• B+3D, B+4D
• B/B+SRI+CRI B-Mode:
• B+CRI
• B/CFM+CRI • User Preset • Edge Enhance
• B+SRI
• B/CFM+SRI • Receiver Frequency • Persistence
• B+CRI+SRI
• B/CFM+CRI+SRI • Gain • SRI, CRI
• Contrast†+SRI
• B/PD+CRI • Dynamic Control • Probe Orientation
• B+CRI/3D+CRI
• B/PD+SRI • Gray Map
• B+SRI/3D+SRI
• B/PD+CRI+SRI
• B+CRI+SRI/3D+CRI+SRI M-Mode/AMM –Mode:
• B/HD-Flow+CRI
• B+CRI/4D+CRI • Gain • Reject
• B/HD-Flow+SRI
• B+SRI/4D+SRI • Dynamic control • M-Cursor, AMM-Cursor
• B/HD-Flow+CRI+SRI
• B+CRI/STIC+CRI • Edge Enhance • Time Scale
Real-time Triplex Mode: PW Doppler Mode:
• B/CFM/PW • B/HD-Flow/PW • Gain • Velocity or Frequency Scale
• B/PD/PW • B/TD/PW • Angle • Spectrum Inversion
Selectable alternating modes: • Sample Volume Depth and • Time Scale
• B+PW or CW • B/TD+PW or CW Width • PRF
• B/CFM+PW or CW • B/HD-Flow+PW or CW • Wall Motion Filter • HPRF
• B/PD+PW or CW • Doppler Frequency
Multi-image (split, quad): Color Flow Imaging modes
• Live and/or frozen • Color Gain • Color Map
• Live Bi-Plane • Color Balance • Color Scale: kHz, cm/s, m/s
• Split: B+B, B/CFM+B/CFM or B/PD+B/PD or B/TD+B/TD or B/HD- • Color Balance Marker • Power and Symmetrical
Flow + B/HD-Flow or BF+BF, Contrast†+Contrast† • Quality Velocity Imaging
• Split simultan: B+B/CFM or B+B/PD or B+B/HD-Flow • Wall Motion Filter • Color Velocity Range
• Split: B+PW or M or CW • PRF • Spectrum Inversion
• Split: Frame Review/XTD-View • Orientation Markers
• Quad: B+B+B+B or BF or Contrast†,
B/CFM+B/CFM+B/CFM+B/CFM or B/PD or B/TD or B/HD-Flow
• Independent Cine playback
• Quad: A+B+C+3D or 4D
• TUI: 1x1, 1x2, 2x2, 3x2, 3x3, 3x4, 4x4
• Segmentation: quad (A/B/C/Segm. Object), single (Segm.
Object)
• Split: TUI Overview+1 slice
• Zoom Read/Write (with or without overview image)
Image Size: Standard & XL Format
Colorized Image: available in B/M/PW/3D
Time line display:
• Independent Dual B/PW Display
• Display Formats: Top/Bottom selectable format
(Size 1/2:1/2; 1/3:2/3; 2/3:1/3)

Display annotation
Patient name: First/Middle/Last Name, max. 62 characters each
ID: max 32 characters
Secondary patient ID (Citizen Service Number)
Accession #: max 16 characters
Hospital Name: max 30 Characters
Sonographer
Gestational age (OB) or LMP (GYN)
Birth date
Date:
• MM/DD/YYYY • DD/MM/YYYY • YYYY/MM/DD
Time display selectable: 12/24 hours
Probe name
Application name
Gray Scale bar

Voluson E8 BT19 Datasheet Page 4 of 18


Display annotation • Start Exam and End Exam configuration
3D/4D Mode:
• 3D/4D Sub Program • TUI: slice distance Measure setup
• Threshold • TUI: slice position in overview M&A Setup including Add, Delete, Edit and Reorder of measure
• Quality image items
• Volume Box Angle • STIC acquisition time
Application Setup including several parameters of Measurement,
• Mix • Calculated heart rate for STIC Doppler Trace and Calculation presets
• Acquisition Mode
Global Setup including several parameters of Measurement,
• Compression
Cursor and Result window presets
• VCI: slice thickness
Post assign measurements
Compression Elastography
Auto Sequence measurements
• Tx Frequency • Elasto Map
• Transparency • Persistence
Biopsy setup
• Velocity Range • Line Density
User programmable needle guidelines
TGC Curve
Cine Frame Number
Pre-processing
Recorder Status
Write Zoom up to 8x
Body Pattern: 124 types organized in 10 anatomical groups
B/M-Mode:
Measurement results • Gain • Transmission Frequency
Displayed Acoustic Output: • TGC • Persistence Control
• TIS: Thermal Index Soft Tissue • Dynamic Range • Line Density Control
• TIC: Thermal Index Cranial (Bone) • Acoustic Output • Reject
• TIB: Thermal Index Bone • Transmission Focus Position • Sweep Speed
• MI: Mechanical Index • Transmission Focus Number • M-Cursor position
Predefined Biopsy Guide Line PW-Mode:
ECG Line • Gain • Wall Motion Filter
Trackball function (Trackball and Trackball buttons) • Dynamic Range • Sample Volume Gate
• Acoustic Output • Length, Depth, Pos
Zoom overview image (zoom box position)
• Transmission Frequency • Velocity Scale
• PRF • Sweep Speed
System Parameters Color Flow Imaging Modes
System setup • Gain • Smooth (Rise and Fall)
User Programmable Preset Capability, User program etc. • Acoustic Output • Frequency
Display Languages: English, French, German, Spanish, • PRF • Balance
Portuguese, Italian, Danish, Dutch, Finnish, Norwegian, Swedish, • Wall Motion Filter • Line Filter
Russian, Japanese, Simplified Chinese • Line density • Quality
Keyboard Languages (Keycap Kits): English, French, German, • Ensemble • Artifact Suppression
Spanish, Italian, Danish, Finnish, Norwegian, Swedish, Russian, • Dynamic
Swiss, South Slavic Latin
eIfU (electronic Instructions for Use) Languages: Post-processing
Bulgarian, Croatian, Czech, Chinese Simplified, Danish, Dutch, Read Zoom: 0.8x – 3.4x Zoom (with HD-Zoom functionality up to
English, Estonian, Finnish, French, German, Greek, Hungarian, 22x Zoom)
Indonesian, Italian, Japanese, Kazakh, Korean, Latvian, B-Mode:
Lithuanian, Norwegian, Polish, Portuguese, Romanian, Russian, • 2D Gain • Colorized B
Serbian, Slovakian, Slovenian, Spanish, Swedish, Turkish,
• Dynamic Contrast • SRI II (Speckle Reduction
Ukrainian, Vietnamese
• Gray Map Imaging)
Free programmable Scan assistant lists including Add, Delete, • Edge Enhance
Edit and Reorder of checklist items
M-Mode:
Up to 800 Programmable Annotations organized in 10 • Gray Map • Display Format
anatomical groups, including a library function and auto-
• Colorized M • Sweep Speed
complete
• Edge Enhance
6 programmable Px buttons for documentation preferences like
PW Mode:
Save, DICOM Send, Print, Check, Cine length, jpeg, etc.
• Gray Map • Scale (kHz, m/s, cm/s)
Several user configurable functions: • Baseline Shift • Trace
• Clinic Name • Angle Correction • Invert
• Display (TGC curve, Screen Lock, Screensaver, Auto Scan Stop, • Colorized D • Sweep Speed
Beeper, 3D/4D Screen Controls)
• Trackball speed Color Flow Imaging Modes • Color Map
• Zoom Overview window • Display Threshold • Scale (CFM and HD-Flow)
• Dim function • Display Mode (V,V-T,T,P,P- • Baseline
T) (CFM only)
• Patient Info display
• Title bar settings

Voluson E8 BT19 Datasheet Page 5 of 18


B-Flow Review of current exam and archived data sets (Single Images
• Gray map and Cine Clips). View format: Raw data, DICOM data. Display
• Colorized B-Flow Formats: 1x1, 2x2, 3x3
• Advanced SRI (Speckle Reduction Imaging) Reload of current/ archived data sets: 2D Raw Data (incl. Color
• Dynamic Contrast Doppler, Spectral Doppler and M-Mode). 3D Raw Data (single
Volume incl. Calc. Cines). 4D Raw Data (Volume Cine).
Image processing and presentation Export as:
Digital Beamformer • Bitmap files: BMP, TIFF, JPEG;
• Raw files: RAW (2D), VOL (Volume data), 4DV
8.040.131 system processing channel technology
• (RAW, VOL incl. Patient data – password protected)
Minimum Depth of Field: 0 – 1 cm (Zoom, probe dependent) • Video File Format: AVI, MP4
Maximum Depth of Field: 0 – 50 cm (probe dependent) • DICOM Files: DCM, DICOM Files with DICOMDIR
Depth Steps: up to 29 (probe dependent) • 3D Raw Data: export Cartesian format possible
Transmission Focus: 1-5 Focus Points selectable (probe and • Surface formats: STL, OBJ, PLY, 3MF, XYZ (with projected and
application dependent) full 3D export capabilities)
Focal Zone position, up to 10 positions selectable AVI Codec: MS Video 1, FullFrames
Continuous Dynamic Receive Focus/ Continuous Dynamic Export to: DVD+R(W), CD-R(W), Network, USB devices, email,
Receive Aperture Printer, DICOM®, TricefyTM
256 gray levels Export Anonymous function: available for following image types:
16.8 million Colors 24 bit AVI, BMP, TIFF, JPEG, MP4
Up to 274 dB Dynamic Range Backup function to: DVD+R(W)/CD-R(W), Network, USB devices
Image reverse: Right/Left Repro function: Settings recall (e.g. Geometry, Gain, Color map,
Rotation: 0°, 180° etc.) from a stored or reloaded picture
Exam history: Direct access to images from previous exams;
direct access to Measure Reports images from previous exams;
Cine features
Image compare window on screen to compare images from
• Cine features: previous exams with current exam image
• Dual/Quad image CINE Display
Hard Drive Data Storage space: approx. 900 GB
• CINE Gauge and CINE image number display
• CINE Review Loop
Connectivity
• Selectable CINE Sequence for CINE Review (by Start Frame and
End Frame) Ethernet network connection
• Side Change in dual CINE Mode 6 USB 3.0 ports for USB devices
• Measurements /Calculations & Annotations on CINE DICOM support:
Length: • Verify
• 2D: 512MB: up to 10 min (depending on B-image size and FPS); • Print
typical: about 3 min/4000 images (with curved array: 15cm • Store
depth, angle 81°, 22 FPS) • Modality Worklist
• M-Mode: 32MB: up to 1 min motion time (depending on sweep • Structured Reporting
and depth) • Storage Commitment
• PW/CW-Mode: 32MB: up to 1 min motion time (depending on • MPPS (Modality performed procedure step)
sweep speed) • Media Exchange
Cine operation: • Off network / mobile storage queue
• Manual: image by image • Query/Retrieve
• Auto run: speed: 25 to 200% of real-time rate, play repeat • TLS
mode: forward-forward, forward-backward-forward TricefyTM features:
• Store
Image/volume storage (archive) • Patient Share
Standard and fully anonymized archive available • .pdf Report storage
Images stored as: • Query Retrieve
• Raw Data file (proprietary format)
• DICOM file (Single-or Multi-Frame)
Volume file stored as:
• Raw Data file (proprietary format)
• DICOM file
Size: typically: 0.8 – 5MB (depending on probe and adjusted
volume size)
Compression:
• 2D: JPEG, lossless, high, mid low
• 3D/4D: Lossy and lossless compression available. Typical
compression rates are 50% with lossless compression, 15%
with lossy compression but maximum quality and 5% with
lossy compression and reduced quality (approximate values).

Voluson E8 BT19 Datasheet Page 6 of 18


Scanning Parameters Working Modes M (conventional M- Mode)
B-Mode AMM (Anatomical M-Mode)
B-Mode for all probes Power control range 1-100
B Acoustic Power 1-100 Gain range +15 to -25 dB
Scan Angle Probe dependent M sweep speeds:
• 900/450/300/225/150/100 pixels/sec;
Gain range +15 to -25 dB
• 26.44/13.22/8.81/6.61/4.40/2.94 cm/s in relation to system
Gray scale values 8 bit monitor
SRI 5 steps (1-5) Review (memory times) >60 s (32MB)
CRI 8 steps (1-8) Signal processing M:
CRI filter 4 steps: off, low, mid, high • Dynamic range: 1 to 12 • Gray maps: 18
CE On/Off (Probe dependent) • Reject: 0 to 255 • Tint maps: 10
FFC On/Off (Probe dependent) • Enhance: 0 to 5
Persistence filter 8 steps (pre) Display Modes:
• M: 2D+M, 2D+M/CFM, 2D+M/HD-Flow, 2D+M/PD, 2D+M/TD
Line filter 3 steps (pre) off, low
• AMM: 2D+AMM, 2D/CFM+AMM/CFM, 2D/HD-Flow+AMM/HD-
(12.5/75/12.5%), high
Flow, 2D/TD+AMM/TD
(25/50/25%)
Screen Formats: (window arrangement)
Line Density 3 steps (pre) low, norm,
• 2D+M and 2D+AMM: up/down (horizontal): three different sub
high
formats 30/70, 50/50, 70/30% left/right (vertical): 50/50%
Reject 51 steps (pre) from 0 to 255 • 2D+AMM+AMM: left/right-up/down: 50/25/25%
Enhance 6 steps 0, 1, 2, 3, 4, 5
Gray maps 21 (18 basic maps and 3 M-Color Flow Mode
User-defined maps) Probes: • RIC5-9-D • C2-9-D
Tint maps 10 • IC5-9-D • S4-10-D • C1-6-D
Dynamic 12 different dynamic • RAB6-D • M5Sc-D
curves C1 – C12 Acoustic MCFM Power 1-100
Display Modes B, XTD MCFM Color Maps 8 maps
Max. B-Mode Frame Rate > 3000 frames/sec CFM Gain +/-15 dB range, 0.1 dB steps
Frequency Range 1 to 18 MHz depending on the CFM Velocity Scale Range PRF: 150Hz to 20.5kHz
probe, adjustable in 3
fundamental steps Wall Motion Filter 8 – 3000 Hz
(penetration, normal, Ensemble (color shots per line) 8-16, step size 1
resolution) and up to 4 Gentle color filter
Harmonic steps (HI Pen, low,
Smooth filter: Rise: 12 steps
mid, high)
Fall: 12 steps
Screen Formats:
CFM Spectrum Inversion
• 2D Imaging: Single (B), Dual (B+B), Quad (B+B+B+B)
• XTD View: Single (XTD), Dual (B+XTD) CFM Baseline Shift 17 steps
Coded Excitation • ML6-15-D • RAB6-D Pre-settable and independently adjustable B-, M and MCFM Gain
(CE): • 11L-D • C2-9 CFM Threshold 1 – 255 steps
• RIC5-9-D Balance 25 – 225, step size 5
Coded Harmonic Imaging available on all probes Artifact suppression On/Off
Focus Frequency • RIC5-9-D • C1-6-D Color Display Mode:
Composite (FFC): • 9L-D • C2-9-D • V (Velocity) • T (Turbulence)
• IC5-9-D • RAB6-D • V-T (Velocity + Turbulence) • P-T (Power + Turbulence)
Compound Resolution Imaging (CRI) available on all probes, • V-P (Velocity + Power)
except: M5Sc-D and S4-10-D Real –time Triplex Mode B + M + MCFM in any depth
Speckle Reduction Imaging (SRI II) available on all probes
Virtual Convex: • RSP6-16-D • 11L-D Spectral Doppler Mode (PW, CW)
• S4-10-D • 9L-D • M5Sc-D Spectral Doppler Mode for all probes
• ML6-15-D Operating Modes PW (Pulsed Wave Doppler, Single Gate),
Wide Sector: • RIC5-9-D • C1-6-D Steerable CW (Continuous Wave
• IC5-9-D • RAB6-D • C2-9-D Doppler)
HI Pen: • RIC5-9-D • C2-9-D Transmit Frequencies PW-Doppler: 1.75-18 MHz
• RAB6-D • IC5-9-D • C1-6-D CW-Doppler: 1.75-16 MHz
Confocal Imaging: • C2-9-D • C1-6-D Pulse Repetition PW-Doppler: 0.9-22 kHz
• M5Sc-D Frequency (PRF) CW-Doppler: 1.3-40.0 kHz
Sample Volume Length: 0.7,1,2,3,4,5,6,
M-Mode (Doppler Gate) 7,8,9,10,15 mm Position: 5 mm to B-scan
end, Angle correction: -85°…0°…+85°
M-Mode for all probes

Voluson E8 BT19 Datasheet Page 7 of 18


Power control range 1-100 Gain Control +15 dB to -15 dB, 0.2 dB steps
Gain range +15 to -25 dB (PW) Line Density (color line density) 10 steps
+15 to -15 dB (CW) Ensemble (color shots per line) CFM: 7 to 31; MCFM: 8 to 16
WMF (wall motion PW: 30…500 Hz, Flow Resolution 4 steps (low, mid1, mid2, high)
filter) CW: 30…1000 Hz
Pulse repetition frequency CFM: 150 Hz to 20.5 kHz
Baseline shift ± PRF/2, ± 8 steps MCFM: 150 Hz to 20.5 kHz
Spectrum Analyzer FFT (Fast Fourier Transformation), Color Map Up to 8 different color codes
max. 256 channels, 256 amplitude levels for each probe
PW sweep speeds Simplex (26.44/13.22/8.81/6.61/4.40/2.94 Frequency range 1 to 18 MHz depending on the
cm/s), Duplex/ Triplex probe, adjustable in 3 steps
(26.44/13.22/8.81/6.61/4.40/2.94 cm/s) (low, mid, high)
Review (memory >60 s(32MB) Balance From 25 to 225
times)
Max. meas. velocity 4.23 m/sec
Measurable flow velocities:
Min. meas. velocity 0.3 cm/sec
• PW: 1cm/s – 8m/s (a=0°, 2.0MHz, max. Baseline shift)
1cm/s – 16m/s (a=60°, 2.0MHz, max. Baseline shift) Scale kHz, cm/s, m/s
• CW: 1cm/s – 11.6m/s (a=0°, 2.0MHz, max. Baseline shift) Automatic moving tissue Yes
1cm/s-23.20m/s (a=60°, 2.0MHz, max. Baseline shift) suppression
Signal processing: Dynamic range: 15 steps (10 to 40), Gray Max. Color Doppler Frame Rate > 450 frames/sec
maps: 18 basic curves and 3 User-defined (pre, post) Tint maps:
11 Power Doppler Mode (PD)
Scale display Vert.: kHz, cm/s, m/s (selectable), Power Doppler Mode for all Probes
Hor.: 1s marker (big), ½ s marker (small)
Screen Formats 2D+PD (Single, Dual, Quad)
Screen Formats 2D/D: up/down (horizontal):
Display Modes:
three different sub formats 30/70, 50/50,
70/30% left/right • Simultaneous dual mode: 2D/2D+PD
(vertical): 50/50% • Triplex mode: 2D+PD/PW
• Volume Mode: 3D+PD
Display Formats 2D/D (duplex update, simultaneous);
2D+CFM/D, 2D+HD-Flow/D, 2D+PD/D, PD coding 256 color steps
2D+TD/D (triplex update, CW or PW). PD window size Lateral: maximum to minimum
2D+CFM/PW, 2D+PD/PW, B mode scan angle
2D+HDFlow/PW, 2D+TD/PW, (triplex Axial: B-scan range
simultaneous, PW only) Display mode P (power)
Audio Modes Stereo (both directions separately in Wall motion Filter 7 steps (low1, low2, mid1, mid2,
both channels) high1, high2, max)
Audio Volume Adjustable, control digipots Smoothing Filter Rising edge: 12 steps
CW Doppler, • S4-10-D • C2-9-D Falling edge: 12 steps
steerable • M5Sc • C1-6-D Gain Control +15 dB to -15 dB, 0.2 dB steps
• 9L-D
PD Ensemble 7 to 31
CW Doppler, non-steerable: RAB6-D
PD Line Density 10 steps
Color Doppler Mode Pulse repetition frequency 150 Hz to 20.5 kHz
Color Doppler Mode for all Probes PD Map 8 different color codes for each
probe
Screen Formats 2D+CFM (Single, Dual, Quad)
Frequency range 1 to 18 MHz depending on the
Display Modes: probe, adjustable in 3 steps
• Simultaneous dual mode: 2D/2D+CFM (low, mid, high)
• Triplex mode: 2D+CFM/PW, 2D/M+MCFM
Flow Resolution 4 steps (low, mid1, mid2, high)
• Volume Mode: 3D+CFM
Balance From 25 to 225 in 41 steps
Color coding:
• Steps: 65536 color steps Artifact suppression Yes
• Display modes: V-T (velocity + turbulence), V (velocity), V-P
(velocity + power), T (turbulence), P-T (power + turbulence) HD-Flow
Depth range Axial: 0 to B scan range HD-Flow Mode for all Probes
Lateral: 0 to B scan range Screen Formats Single, Dual, Quad, 2D+HDF
Baseline shift 17 steps (independent Display Modes:
from spectral Doppler) • Simultaneous dual mode: 2D/2D+HDF
Inversion of color direction Yes • Triplex mode: 2D+HDF/PW; 2D/M+MHDF
Wall Motion Filter 7 steps (low1, low2, mid1, • Volume mode: 3D+HDF
mid2, high1, high2, max) HD-Flow Coding Steps 256 color steps
Smoothing Filter 12 steps rising time, HD-Flow window size lateral Maximal to minimal B mode
12 steps falling time scan angle; axial: B-scan range

Voluson E8 BT19 Datasheet Page 8 of 18


Wall Motion Filter 8 steps (low1, low2, mid1, mid2, 2D/2D+TD; Triplex mode:
high1, high2, max1, max2) 2D+TD/PW, 2D/M+MTD;
Smoothing Filter 12 steps rising edge TD coding steps 65536 color steps
12 steps falling edge Depth range Axial: 0 to B-scan range
Gain Control +15 dB to -15 dB, 0.2 dB steps Lateral: 0 to B-scan-range
HD-Flow Ensemble 7 to 31 Baseline shift 17 steps
HD-Flow Line Density 10 steps Inversion of color direction Yes
Pulse repetition frequency 150 Hz to 20.5 kHz Smoothing Filter 12 steps rising time,
HD-Flow Map 8 different color codes for each 12 steps falling time
probe Gain Control +15 dB to -15 dB, 0.2 dB steps
1 to 18 MHz depending on the Line Density (color line density) 10 steps
Frequency Range probe adjustable in three steps Ensemble (Color shots per line) 3 to 31
(low, mid, high)
Flow Resolution 4 steps (low, mid1, mid2, high)
Flow Resolution 4 steps (low, mid1, mid2, high)
Pulse repetition frequency 150 Hz to 20.5 kHz
Balance From 25 to 225
TD Map 4 different color codes for each
Line Filter 8 steps (off, 1 to 7) probe
Artifact suppression Yes Frequency range 1 to 18 MHz depending on the
probe, adjustable in 3 steps
Radiantflow (low, mid, high)
• RIC5-9-D • 9L-D • C2-9-D Balance From 25 to 225
• IC5-9-D • RAB6-D • C1-6-D Max. meas. velocity 4.23 m/sec
• ML6-15-D • M5Sc-D Min. meas. velocity 0.3 cm/sec
Steps low/mid/high Display Mode V (velocity)
Scale kHz, cm/s, m/s
SlowFlowHD
Probes: • ML6-15-D • RAB6-D PW-Tissue Doppler Mode (PW-TD)
• RIC5-9-D • C1-6-D • C2-9-D
Probes: • RAB6-D • C2-9-D
• IC5-9-D
• RIC5-9-D • S4-10-D • C1-6-D
Screen Formats Single, Dual, Quad, 2D+ • M5Sc-D
SlowFlowHD
Operating Modes 2D+TD/PW (Tissue Doppler +
Display Modes: Pulsed Wave Doppler, Single
• Simultaneous dual mode: 2D/2D+ SlowFlowHD Gate)
Triplex mode: 2D+ SlowFlowHD /PW (triplex update); 2D+
Transmit Frequencies 1.75..18 MHz
SlowFlowHD /AMM
Pulse Repetition Frequency 0.9..7.0 kHz
SlowFlowHD Coding Steps 256 color steps
(PRF)
SlowFlowHD window size Maximal to minimal B mode
lateral scan angle; axial: B-scan range Sample Volume Length: 0.7,1,2,3,4,5,6,
(Doppler Gate) 7,8,9,10,15 mm Position: 5 mm
Wall Motion Filter 8 steps (low1, low2, mid1, mid2, to B-scan end, Angle
high1, high2, max1, max2) correction: -85°…0°…+85°
Smoothing Filter 12 steps Power control range 1-100
Gain Control +15 dB to -15 dB, 0.2 dB steps Gain range B-Mode: +15 to -25 dB
Line Density 10 steps TD: +15 to -15 dB
Pulse repetition frequency auto adjusting PW: +15 to -25 dB
Map 8 different color codes for each WMF (Wall Motion Filter) PW: 30…500 Hz,
probe Baseline shift ± PRF/2, ± 8 steps
1 to 18 MHz depending on the Spectrum Analyzer max. 128 frequencies, 256
Frequency Range probe adjustable in three steps amplitude levels
(low, mid, high) PW sweep speeds Duplex/Triplex (26.44 / 13.22 /
Flow Resolution 4 steps (low, mid1, mid2, high) 8.81 / 6.61 / 4.40 / 2.94 cm/s)
Balance From 25 to 225 Review (memory time) >60 s (32MB)
Line Filter 8 steps (off, 1 to 7) Measurable velocities 1cm/s – 1.3m/s (a = 0°, 2.0MHz,
Artifact suppression 4 steps (off, low, mid, high) max. zero shift)
1cm/s – 2.5m/s (a = 60°,
Tissue Doppler Mode (TD) 2.0MHz, max. zero shift)
Probes: • RAB6-D • C2-9-D Signal processing Dynamic range: 15 steps (10 to
• RIC5-9-D • S4-10-D • C1-6-D 40)
• M5Sc-D Gray maps: 18 basic curves
Screen Formats Single, Dual, Quad, 2D+TD and 3 User-defined (pre, post)
Tint maps: 11
Display Modes Simultaneous dual mode:

Voluson E8 BT19 Datasheet Page 9 of 18


Scale display Vert.: kHz, cm/s, m/s - VOCAL: semi-auto/ manual segmentation tool (segmentation
(selectable) using touch screen), (3D Static only) + Threshold Volume:
Hor.: 1s marker (big), ½ s measure volume below and above a threshold
marker (small) - SonoAVCfollicle (Sono Automated Volume Count)
Screen Formats 2D+TD/PW: horizontal: - SonoAVCantral
three different sub formats - SonoAVCgeneral
30/70, 50/50, 70/30% • VCI (Volume Contrast Imaging)
vertical: 50/50% • HDlive Studio: 3 free moveable light sources and types
Display Formats 2D+TD/PW (duplex/triplex Render Modes:
update/simultaneous); • HDlive Silhouette • HDlive Studio
Audio-Modes Stereo (both directions • HDlive Flow • HDlive Flow Silhouette
separately in both channels) • Surface Enhanced • Transparency modes: max-
Audio Volume Adjustable • Color min- and X-ray
• Mix Mode of two render • Gradient Light
modes • Inversion
Volume Scan Module
• Surface Texture • Glass Body
Vol. scan size: max. 64 MB for gray volumes, max. 90 MB for color • Surface Smooth • Light
volumes; The required memory space depends on scan
Display graphics:
parameters (VOL-box size and quality (low, mid1, mid2, high1,
high2, max). Typical: 0.8-5 MB • Rotation axis, center point
• ROI box, 3D Frame
Lines/2D-image: max. 1024 (typ. 80 to 350)
• Temporary display of onscreen controls (rotation, translation)
2D-images/volume: Up to 4096 (Acquisition mode dependent)
Gray maps: Slices: 21 (18 basic curves and 3 User-defined (pre,
VOL-Frames/sec.: max. 46 (typ. 4-8); The frame rate depends on post) 3D Image: one general map adjustable with bright (-50 to
scan parameters: VOL-box size, quality and probe +50) & contrast (-50 to +50))
4D Volume Cine: up to 400 volumes, up to 512 MB Tint maps: Slices: 10; 3D image: 10
Display of sectional plane images: synchronous with control Depth render maps: 3
seeing, arbitrary movement in volume, monitored position in
volume
BF (B-Flow)
Rotation: 360°, 1° or 3° increments (X-, Y- and Z-axis)
B-Flow for all probes except: S4-10-D and M5Sc
Magnification. Adjustable form 0.3 to a factor of 4.00
Screen Formats Single (BF), Dual (BF+BF), Quad
Acquisition Modes: (BF+BF+BF+BF)
• 3D Static: • 4D: Display Modes BF, Update: BF/PW
- 3D (2D incl. CRI) - 4D Real Time
- 3D/PD (incl. CRI) - 4D Biopsy Acc. Power range 1 – 100
- 3D/CFM (incl. CRI) - VCI-A Scan angle Taken from 2D
- 3D B-Flow - VCI-OmniView Gain range +15 to -25 dB
- 3D/HD-flow incl. CRI - STIC
Gray scale values 8 bit
- 3D Contrast† (Coded PI, CCIS)
SRI Taken from 2D
• STIC:
Persistence filter 8 steps (pre)
- Fetal Cardio
- STIC Angio: B/Power Doppler (incl. CRI) S./PRI 1.00, 1.50, 2.00, 3.00, 4.00, 5.00
- STIC CFM: B/Color Doppler (incl. CRI) Quality 3 steps (pre) low, norm, high
- STIC HD-Flow: B/HD-Flow (incl. CRI) Enhance 6 steps (pre) 0, 1, 2, 3, 4, 5
- STIC B-Flow
- STIC TD Gray maps 21 (18 basic maps and 3 User-
-STIC with Contrast† defined maps)
Visualization Modes: Tint maps 10
• Render Dynamic 12 different dynamic curves C1
- 3D/4D Rendering (diverse surface and intensity projection – C12
modes) Accumulation Off, 0.20, 0.35, 0.50, 0.75, 1.00,
- SonoRenderlive 1.50, Infinite
• Sectional Planes Background 0, 1, 2
- Multiplanar
- OmniView, actual and projected view
Contrast Imaging†
- Niche
- SonoVCADlabor Probes: • ML6-15-D • 9L-D
• C1-6-D • M5Sc-D • RIC5-9-D
• TUI (Tomographic Ultrasound Imaging) (overview
image+parallel slices) Acc. Power range 1 – 100
- TUI Standard Scan angle Taken from 2D
- SonoVCADheart Gain range +15 to -25 dB
Visualization Modes: Gray scale values 32 bit
• Volume Analysis
SRI Taken from 2D
Persistence filter 8 steps (pre)

Voluson E8 BT19 Datasheet Page 10 of 18


S./PRI 1.00, 1.50, 2.00, 3.00, 4.00, Measurements
5.00 Generic measurements
Quality 3 steps low, norm, high Distance:
Enhance 6 steps (pre) 0, 1, 2, 3, 4, 5 • Distance (Point to Point) • 2D Trace (Point Length)
Gray maps 21 (18 basic maps and 3 • Distance (Line to Line) • Stenosis (% Dist.)
User-defined maps) • 2D Trace (Trace Length) • Ratio D1/D2
Tint maps 10 Area/Circumference:
Dynamic 12 different dynamic • Ellipse • Stenosis (%Area)
curves C1 – C12 • Trace (Line) • Area (2 Dist.)
Accumulation Off, 0.20, 0.35, 0.50, 0.75, • Trace (Point) • Ratio A1/A2
1.00, 1.50, Infinite Volume: following Methods:
Background 0, 1, 2 • 1 Distance • 3 Distance
• 1 Ellipse • Multiplane-Planimetric
Time Delay 0, 0.5, 1, 2, 3, …10
• 1 Dist. + Ellipse Volume (3D only)
Display Modes:
Angle:
• Coded PI • Coded PI: CIS • Coded PI: CCIS
• Angle (3 Point) • Angle (2 Line)
Screen Formats:
M-Mode:
• Code PI: Single (B), Dual (B+B), Quad (B+B+B+B)
• Distance (Point to Point) • HR
• CIS: Dual simultan (2D+Coded PI)
• Time • Stenosis (% Dist.)
• CCIS: Single (B), Dual (B+B), Quad (B+B+B+B
• Slope • IMT
• Vessel Diam. • Stenosis Diam.
Compression Elastography • Ratio D1/D2
Probes: PW Doppler Mode:
• RIC5-9D • IC5-9-D • Auto & Manual Trace:
• 11L-D • ML6-15D - PS (Peak Systole)
Acoustic Power range: 1 – 100 - ED (End Diastole)
Tx Frequency: 3 (penet/norm/resol) - MD (Mid. Diastole)
- S/D (Ratio)
Transparency: 51 steps (0,5, 10, …255)
- TAmax
Soft Compress: - HR
• Range: 0-9 • Step Size: 1 - PI (Pulsatility Index)
Hard Compress - RI (Resistance Index)
• Range: 0-9 • Step Size: 1 • Vol. Flow
PRF: 10, 15, 25, 40, 60, 85 Hz • PGmax, PGmean
• TAmax (Time avg. max. Velocity)
Elasto Maps: 8
• TAmean (Time avg. mean Velocity)
Persistence: • VTI (Velocity Time Integral)
• Range: 1-9 • Step Size: 1 Heart Rate
Line Dens.: Range: 1-2 Vessel:
Filter Axial: • R/L Vessel area • R/L Stenosis area
• Range: 1-9 • Step Size: 1 • R/L Vessel diam. • R/L Stenosis diam.
Filter Lateral: • R/L IMT • R/L Flow diam.
• Range: 1-21 • Step Size: 2 Single • PS/ED • Acceleration
Window Length: Measurements: • RI • HR
• Range: 8-25 • Step Size: 1 • Velocity • PI • ED
• Time • PS
Screen Formats:
• Single (2D/Elasto)
• Dual (2D/Elasto+2D/Elasto) Abdomen calculations
• Quad (2D/Elasto+2D/Elasto+2D/Elasto+2D/Elasto) Liver Gallbladder
Elastography Analysis Pancreas Spleen
Elastography Ratio Measurement Kidney (right/left) Renal Artery (right/left)
Aorta (Proximal, Mid, Distal) Portal Vein
Shearwave Elastography (May not be available in all countries) Vessel Bladder Volume
Probes: • C1-6-D Summary Reports
Acoustic Power range: 1 – 100
Gain: 0 - 100 Small part calculations
Frequency: 50 – 400 Hz Thyroid (right/left)
Transparency: 51 steps (0,5, 10, …255) Testicle (right/left)
Elasto Maps: 8 Dorsal Penile Artery (right/left)
Velocity Scale: 2,0 – 10,0 m/s (22 steps) Vessel
Summary Reports

Voluson E8 BT19 Datasheet Page 11 of 18


• Aortic Arch • 4 Chambers
Small part breast calculations • Short Axis • Summary Reports
Lesion 1-5 (right/left) • Thorax
Summary Reports
fetalHQ
Obstetrics calculations • Global Heart Size: Length, Width, Area, Axis
Fetal Biometry • Global Heart Shape: Sphericity Index
• Ventricular Size (for RV & LV): Area, BAL, Transverse Diameter
Early Gestation
(24 segment)
Fetal Long Bones • Ventricular Shape (for RV & LV): Sphericity Index (24 segment)
Fetal Cranium • Ventricular Contractility: Area Fractional Shortening, Global
NT Method: SonoNT/Manual Strain, Transverse Diameter Shortening (24 segment), BAL
AFI Shortening, Annular Plane Systolic Excursion, Lateral and
Septal Wall Strain
Uterus
Ovary right/left Cardiology calculations
Umbilical Vein 2D Mode:
Placenta Volume • LV Simpson (Single & Bi-Plane)
Ductus venosus: S, D, a, PI, PLI, PVIV • Volume (Area Length)
Doppler measurements: Ductus Art., Ductus Ven., Ao, Carotid, • LV-Mass (Epi & Endo Area, LV Length)
MCA, Celiac Artery, Superior Mesenteric Artery, Umbilical Art., • LV (RVD, IVS, LVD, LVPW)
Umbilical Vein, FHR, Uterine Art. • LVOT Diameter
Gestational Age Calculation • RVOT Diameter
• MV (Dist A, Dist B, Area)
Gestational Growth Calculation
• TV (Diameter)
Fractional limb Volume • AV/LA (Aortic Valve/Left Atrium)
Fetal Weight (FW) Estimation • PV (Diameter)
Fetal Trend Graph M-Mode:
Multi-Gestational Calculation & Fetal Compare • LV (IVS, LVD, LVPW, RVD)
Calculation and Ratios • AV/LA (Ao Root Diam, LA Diam, AV Cusp Sep., Ao Root Ampl)
• MV(D-E, E-F Slope, A-C Interval, EPSS)
Fetal Qualitative Description (Anatomical surv
• HR (Heart Rate) Atrial HR
Fetal Environmental Description (Biophysical profile)
PW-Mode:
Summary Reports • MV (Mitral Valve)
• AV (Aortic Valve), TV (Tricuspid Valve)
Obstetrics Fetal Echo • PV (Pulmonary Valve)
Chambers • LVOT & RVOT Doppler (Left & Right Ventricle Outflow Tract)
Thorax • Pulmonic Veins
Aorta/LVOT • PAP (Pulmonary Artery Pressure measurement)
• HR (Heart Rate)
Pulmonary/RVOT
• TEI-Index
Venous
C-Mode:
fetalHQ • PISA
FHR Others:
Tricuspid valve • Diast. Vol (Bi) • Mean Gradient
Mitral Valve • Syst. Vol. (Bi) • Mean Gradient Acceleration
Aortic • Stroke Volume • VTI
• Volume Flow • TVA
Pulmonary
• Cardiac Output • PG
LPA • Ejection Fraction • PHT
RPA • Fractional Shortening • MVA
Ductus Art. • Myocardial Thickness • AVA
Cardiac Output • LA/Ao Ratio • ERO
• E/A Peak • CVP (Cardio Vascular Profile)
LT TEI
• Peak Gradient Acceleration Score
RT TEI
Summary Reports
Ductus Ven.
Umbilical Vein Transrectal calculations
Pulmonary Veins Prostate
Summary Reports Vessel
Summary Reports incl. PSAD, PPSA(1), PPSA(2) calculation
Obstetrics Z-scores
• Long Axis • Obl. Short axis

Voluson E8 BT19 Datasheet Page 12 of 18


OB Tables
Vascular calculations Age Tables
Left/Right CCA (Common Carotid Artery) • AC: ASUM, CFEF, Hadlock_82, Hadlock_84, Hansmann,
Left/Right ICA (Internal Carotid Artery) Hobbins, Jeanty, JSUM, Kurmanavicius, Merz, Nicolaides,
Left/Right ECA (External Carotid Artery) Shinozuka, Siriraj, Tokyo
Left/Right Vertebral Artery • AD. Persson
• APAD: Merz
Left/Right Subclav.
• APTD: Hansmann
Left/Right Bulb • APTDxTTD: Shinozuka, Tokyo
Vessels • BOD: Jeanty
Summary Reports • BPD: ASUM, ASUM (old), Campbell, CFEF, Chitty (outer-outer)
(outer-inner), Eik-Nes, Hadlock_82, Hadlock_84, Hansmann,
Gynecology calculations Hobbins, Jeanty, Johnsen, JSUM, Kurmanavicius, Kurtz, Leung,
McLennanPersson, Merz, Nicolaides, OSAKA, Rempen,
Uterus Sabbagha, Shinozuka, Siriraj, Tokyo, Verburg
Left/Right Ovary • CEREB: Chitty, Goldstein, HILL, Hobbins, Nicolaides, Verburg
Left/Right Follicle • CLAV: YARKONI
Fibroid • CRL: ASUM, DAYA, Eik-Nes, Hadlock, Hansmann, Intergrowth,
JSUM, McLennan, Persson, Pexters, Nelson, OSAKA, Rempen,
Endometrial thickness (Dist, Double Dist.)
Robinson, Robinson_BMUS, Sahota, Shinozuka, Tokyo, Verburg
Cervix Length • FL: ASUM, CFEF, Chitty, Eik-Nes, Hadlock_82, Hadlock_84,
Left/Right Ovarian Artery Hansmann, Hobbins, Hohler, Jeanty, JSUM, Kurmanavicius,
Left/Right Uterine Artery Leung, Persson, Merz, Nicolaides, O’Brien, OSAKA, Shinozuka,
Siriraj, Tokyo, WARDA, Johnsen
Vessels
• FTA: OSAKA
Pelvic Floor • FIB: Jeanty
Left/Right Ovarian Cyst • GS: Hansmann, Hellman, Holländer, Rempen, Tokyo
Left/Right Ovarian Mass • HC: ASUM, CFEF, Chitty, Hadlock_82, Hadlock_84, Hansmann,
Left/Right Adnexal Cyst Jeanty, Kurmanavicius, Leung, Merz, Nicolaides, Siriraj, Johnsen
• HL: ASUM, Hobbins, Jeanty, Merz, OSAKA
Generic Cyst
• LV: Tokyo
Left/Right Adnexal Mass • MAD: Eik-Nes, eSnurra, Kurmanavicius
Generic Mass • OFD: ASUM, Chitty, Hansmann, Jeanty, Kurmanavicius, Merz,
Bladder (Length/Width/Height/Vol) Nicolaides
FHR • RAD: Jeanty, Merz
• TIB: Jeanty Merz
GYN IOTA LR2, Simple Rules and ADNEX Model. (May not be
• TAD: CFEF, Merz
available in all countries)
• TTD: Hansmann
IETA unenhanced ultrasound examination and enhanced • ULNA: Jeanty, Merz
ultrasound examination – Sonohysterography. (May not be
available in all countries)
Growth Tables
Uterus classification (ESHRE/ESGE and ASRM)
• AC: ASUM, CFEF, Chitty, Hadlock, Hansmann, Jacot-Guillarmod,
Summary Reports Jeanty, JSUM, Lai_Yeo, Kurmanavicius, Lessoway, Leung, Merz,
Nicolaides, Shinozuka, Siriraj, Tokyo, Verburg, Johnsen,
Pediatric calculations Medvedev, Stork, Intergrowth, WHO
Left/Right Hip Joint • AD: Persson
Pericallosal Artery • AFI: Moore
• Aorta: Vmax: Rizzo
Summary Report
• APAD: Merz
• APTD: Hansmann
Cephalic calculations • APTDxTTD: Shinozuka_SD
Left/Right ACA (Anterior Cerebral Artery) • AxT: Shinozuka, Tokyo
Left/Right MCA (Middle Cerebral Artery) • BOD: Jeanty
Left/Right PCA (Posterior Cerebral Artery) • BPD: ASUM, Campbell, CFEF, Chitty, Eik-Nes, Hadlock,
Hansmann, Jacot-Guillarmod, Jeanty, JSUM, Kurmanavicius,
Basilar Artery
Lai_Yeo, Lessoway, Leung, Persson, McLenna, Merz, Nicolaides,
A-Com. A (Anterior Com. Artery) OSAKA, Paladini, Sabbagha, Shinozuka, Siriraj, Tokyo, Verburg,
P-Com. A (Posterior Com. Artery) Medvedev, Stork, Intergrowth, WHO
Left/Right CCA (Common Carotid Artery) • CLAV: YARKONI
• CM: Nicolaides
Left/Right ICA (Internal Carotid Artery)
• CRL: ASUM, Hadlock, Hansmann, Intergrowth, JSUM,
Left/Right Vertebral Artery McLennan, Persson, OSAKA, Robinson, Robinson 1993,
Vessels Shinozuka, Tokyo, Pexters, Medvevev
Summary Reports • DV a/S: JSUM
• DV PI: Baschat, JSUM

Voluson E8 BT19 Datasheet Page 13 of 18


• DV PLI: Baschat • Persson 2, Schild (HC, AC, FL)
• DV PVIV: Baschat • Shepard (AC, BPD)
• DV S/a: Baschat • Shinozuka 1 (BPD, ADTP, TTD, FL)
• FL: ASUM, CFEF, Chitty, Eik-Nes, Hadlock, Hansmann, Jacot- • Shinozuka 2 (BPD, FL, AC)
Guillarmod, Jeanty, JSUM, Kurmanavicius, Lessoway, Lai_Yeo, • Shinozuka 3 (BPD, APTD, TTD, LV
Lessoway, Leung, Paladini, Persson, Merz, Nicolaides, O’Brien, • Tokyo (BPD, APTD, TTD, FL)
OSAKA, Shinozuka, Siriaj, Tokyo, Verburg, WARDA, Johnsen, Gestational Age by EFW
Medvedev, Stork, Intergrowth, WHO
• Hadlock, JSUM 2001, Osaka, Shinozuka, Tokyo
• FTA: OSAKA
• FIB: Chitty, Jeanty, JFFSD, Siriraj Fetal Weight Growth FWG
• FWg: Alexander • Alexander, Ananth, Bourgogne, Brenner, Burgundy, CFEF,
Doubilet, Duryea, Ego, Eik-Nes, Hadlock, Hansmann,
• Foot: Chitty
Hansmann (86), Hobbins/Persutte, Intergrowth, Johnsen, Jsum
• GS: Hellman, Nyberg, Rempen, Tokyo
2001, Kramer, Persson, Osaka, Shinozuka, Tokyo, Williams,
• HC: ASUM, CFEF, Chervernak, Chitty, Hadlock, Hansmann, WHO, Yarkoni
Jacot-Guillarmod, Jeanty, Kurmanavicius, Lai_Yeo, Lessoway,
Leung, Merz, Nicolaides, Paladini, Siriraj, Verburg, Johnsen,
Medvedev, Stork, Intergrowth, WHO Fetal Ratios
• HL: ASUM, Chitty, Jeanty, Lai_Yeo, Merz, JFFSD, OSAKA, CI (BPD/OFD) (Hadlock)
Paladini, Siriraj, Medvedev FL/AC (Hadlock)
• IVC PLI: JSUM FL/BPD (Hohler)
• Lt.Tei(ICT,IRT), Lt.Tei(a,b): Bhorat
FL/HC (Hadlock), (WHO)
• Lung Area Left/Right: Peralta
• LV: Tokyo HC/AC (Campbell)
• MCA CP: Ebbing Va/Hem (Nicolaides)
• MCA PI: Ebbing Va/Hem (Hansmann)
• MCA PI, RI: JSUM, Bahlman Vp/Hem (Nicolaides)
• MCA PV: Mari
LHR (Peralta)
• MAD: Eik-Nes, eSnurra, Kurmanavicius
• MV E/A: HARADA CVR (Peranteau)
• NBL: BUNDUKI, SONEK, Medvedev
• OFD: ASUM, Chitty, Hansmann, Jeanty, Kurmanavicius, Merz,
Nicolaides, Medvedev, Intergrowth
• MainPA Vmax: Rizzo
• RAD: Chitty, Jeanty, JFFSD, Merz, Paladini, Sirirja
• SAG. AP: Malinger
• SAG. CC: Malinger
• TAD: CFEF, Jacot-Guillarmod, Merz
• TC: Chitkara
• TCD: Goldstein, Hill, Jacot-Guillarmod, Nicolaides, Verburg
• TIB: Chitty, Jeanty, JFFSD, Merz, Siriraj
• TTD: Hansmann
• TV E/A: HARADA
• ULNA. Chitty, Jeanty, JFFSD, Merz, Siriraj
• UmbArt PI: Ebbing, JSUM, Merz
• UmbArt RI: JSUM, Merz, Kurmanavicius
• UtArtPI: Gomez, Merz
• UtArtRI: Merz
• Vermis A: Malinger
• Vermis C: Malinger
• Fractional Limb Avol/Tvol: Lee

Fetal Weight Estimation (EFW)


• Campbell (AC)
• Hadlock (AC, BPD)
• Hadlock 1 (AC, FL)
• Hadlock 2 (BPD, AC, FL)
• Hadlock 3 (HC, AC, FL)
• Hadlock 4 (BPD, HC, AC, FL)
• Hansmann (BPD, TTD)
• Intergrowth (AC, HC)
• Lee (AVOL; AC, AVOL; AC, BDP, AVOL; TVOL; AC, TVOL; AC, BDP,
TVOL)
• Merz (AC, BPD)
• Osaka (BPD, FTA, FL)
• Persson (BPD, MAD, FL)

Voluson E8 BT19 Datasheet Page 14 of 18


Probes
11L-D
C1-6-D Wide Band Linear Probe
XDClear Wide Band Convex Probe Applications Small Parts, Pediatrics, MSK,
Applications Abdomen, OB, GYN, Fetal Peripheral Vascular, Breast
Cardio Max. Bandwidth (-20dB) 4-10 MHz
Max. Bandwidth (-20dB) 2-5 MHz Number of Elements 192
Number of Elements 192 FOV 38 mm
Convex Radius 55 mm Foot Print 46.9 x 14.4 mm
FOV 113º Depth Max. 11 cm
Foot Print 67.2 x 11.5 mm B-Mode Steering Angle 7°/14°/20°
Depth Max. 50 cm Doppler Steering Angle 7°/14°/20°
Center Frequency 3.4 MHz Center Frequency 7.3 MHz
B-Mode Frequency 2.00 – 2.00 MHz B-Mode Frequency 6.67 – 10.00 MHz
Doppler Frequency 2.50 – 3.85 MHz Doppler Frequency 5.26 – 7.14 MHz
Harmonic Frequency 2.00 – 2.56 MHz Harmonic Frequency 4.55 – 5.00 MHz
Biopsy Guide Available Multi-Angle, disposable with Biopsy Guide Available Multi-Angle, disposable with
reusable bracket reusable bracket

C2-9-D 9L-D
XDClear Wide Band Convex Probe Wide Band Linear Probe
Applications Abdomen, OB, GYN, Pediatrics Applications Small Parts, Pediatrics, MSK,
Max. Bandwidth (-20dB) 3-9 MHz Peripheral Vascular, OB
Number of Elements 192 Max. Bandwidth (-20dB) 3-8 MHz
Convex Radius 43 mm Number of Elements 192
FOV 94º FOV 44 mm
Foot Print 48.0 x 9.0 mm Foot Print 53.0 x 14.1 mm
Depth Max. 26 cm Depth Max. 14 cm
Center Frequency 5.0 MHz B-Mode Steering Angle 7°/14°/20°
B-Mode Frequency 4.00 – 7.14 MHz Doppler Steering Angle 7°/14°/20°
Doppler Frequency 3.03 – 5.00 MHz Center Frequency 5.5 MHz
Harmonic Frequency 2.63 – 3.57 MHz B-Mode Frequency 4.55 – 10.00 MHz
Biopsy Guide Available Multi-Angle, disposable with Doppler Frequency 3.70 – 5.26 MHz
reusable bracket Harmonic Frequency 2.86 – 2.86 MHz
Biopsy Guide Available Multi-Angle, disposable with
IC5-9-D reusable bracket
Wide Band Convex Probe
Applications OB, GYN, Transrectal ML6-15-D
Max. Bandwidth (-20dB) 4-9 MHz Wide Band Matrix Linear Probe
Number of Elements 192 Applications Small Parts, Peripheral
Vascular, Pediatrics, MSK,
Convex Radius 11 mm Breast
FOV 179° Max. Bandwidth (-20dB) 4-13 MHz
Foot Print 21.2 x 17.2 mm Number of Elements 1008
Depth Max. 16 cm FOV 50 mm
Center Frequency 5.8 MHz Foot Print 60.7 x 16 mm
B-Mode Frequency 5.00 – 9.09 MHz Depth Max. 16 cm
Doppler Frequency 4.55 – 6.25 MHz B-Mode Steering Angle 7°/14°/20°
Harmonic Frequency 3.45 – 3.85 MHz Doppler Steering Angle 7°/14°/20°
Biopsy Guide Available Single-Angle, Reusable and Center Frequency 9.0 MHz
disposable
B-Mode Frequency 8.33 – 11.11 MHz
Doppler Frequency 6.25 – 9.09 MHz
Harmonic Frequency 5.00 – 6.25 MHz
Biopsy Guide Available Multi-Angle, disposable with
reusable bracket

Voluson E8 BT19 Datasheet Page 15 of 18


Probes (cont.)
M5Sc-D
RAB6-D XDClear Wide Band Phased Array Probe
Wide Band Convex Volume Probe Applications Abdominal, Cardiology, OB,
Applications Abdomen, OB, GYN, Pediatrics Fetal Echo, Pediatrics, Cephalic
Max. Bandwidth (-20dB) 2-8 MHz Max. Bandwidth (-20dB) 1-5MHz
Number of Elements 192 Number of Elements 240
Convex Radius 47 mm FOV 90°
Volume Sweep Radius 24 mm Foot Print 27.5 x 18.1 mm
FOV 90° (B), 90° x 85° (Volume scan) Depth Max. 24 cm
Foot Print 62.2 x 34.0 mm Center Frequency 2.9 MHz
Depth Max. 26 cm B-Mode Frequency 2.44 – 3.33 MHz
Center Frequency 4.7 MHz Doppler Frequency 1.85 – 2.50 MHz
B-Mode Frequency 3.23 – 6.67 MHz Harmonic Frequency 1.61 – 2.17 MHz
Doppler Frequency 3.03 – 5.00 MHz Biopsy Guide Available Multi-Angle, disposable with
reusable bracket
Harmonic Frequency 2.56 – 3.70 MHz
Biopsy Guide Available Multi-Angle, disposable with
S4-10-D
reusable bracket
Wide Band Phased Array Probe
RIC5-9-D Applications Small Parts, Cardiology,
Pediatrics
Wide Band Convex Volume Probe
Max. Bandwidth (-20dB) 4-9 MHz
Applications OB, GYN, Transrectal
Number of Elements 128
Max. Bandwidth (-20dB) 4-9 MHz
FOV 90°
Number of Elements 192
Foot Print 20.0 x 15.0 mm
Convex Radius 12 mm
Depth Max. 14 cm
Volume Sweep Radius 12 mm
Center Frequency 6.3 MHz
FOV 180°(B), 180° x 120° (Volume
scan) B-Mode Frequency 5.88 – 7.14 MHz
Foot Print 22.4 x 22.6 mm Doppler Frequency 3.85 – 6.25 MHz
Depth Max. 16 cm Harmonic Frequency 4.00 – 4.35 MHz
Center Frequency 6.6 MHz Biopsy Guide Available Not available
B-Mode Frequency 5.00 – 9.09 MHz
Doppler Frequency 4.55 – 6.25 MHz
Harmonic Frequency 3.45 – 3.85 MHz
Biopsy Guide Available Single-Angle, Reusable,
Disposable, disposable with
latex cover

RSP6-16-D
Wide Band Linear Volume Probe
Applications Small Parts, Pediatrics, MSK,
Peripheral Vascular, Breast
Max. Bandwidth (-20dB) 6-18 MHz
Number of Elements 192
Volume Sweep Radius 81 mm
FOV 38.4 mm (B), 38.4 mm x 29°
(Volume scan)
Foot Print 48.6 x 55.9 mm
Depth Max. 8 cm
B-Mode Steering Angle 7°/14°/20°
Doppler Steering Angle 7°/14°/20°
Center Frequency 11.5 MHz
B-Mode Frequency 8.33 – 12.50 MHz
Doppler Frequency 6.25 – 8.33 MHz
Harmonic Frequency 5.26 – 5.26 MHz
Biopsy Guide Available Single-Angle, disposable with
reusable bracket

Voluson E8 BT19 Datasheet Page 16 of 18


External Inputs and Outputs
External Connectivity (direct access)
• VGA out
• Network (RJ45)
• Wireless Network interface (USB) (Option)
• USB 3.0 (6x)
• S-Video Out 1
• HDMI
Connectivity behind rear panel (access after opening):
• Audio in/Out
- Left/right
Ext. Device/Remote Connections:
• BW Printer via USB
• Color Printer/ via USB
• DVR via USB
• Footswitch via USB
• Wireless Network interface (USB) (Option)
• RS 232: via USB to RS 232 converter (Option)
• ECG (Option)

Service Tools
Data Export capabilities for Asset Performance Analytics
On-board probe quality assessment tool

Voluson E8 BT19 Datasheet Page 17 of 18


Safety Conformance
The Voluson E8 is:
NRTL certified according IEC 60601-1 (TÜVPS)
Certified to CSA 22.2, 60601.1 by an SCC accredited Test Lab
CB-Test Report by National Certification Body
CE Marked to Council Directive 93/42/EEC on Medical Devices

The Voluson E8 conforms to the following safety standards


IEC 60601-1 Electrical Medical Equipment
IEC 60601-1-2 Electromagnetic compatibility
IEC 62304 Software Life Cycle Processes
IEC 62366 Application of usability engineering to medical
devices
EN 60601-2-37 Particular requirements for the safety of
ultrasound medical diagnostic and monitoring equipment
IEC 601157 Declaration of acoustic output
ISO 10993 Biological evaluation of medical devices
IEC 62359 Ultrasonic - Field characterization - Test methods
for the determination of thermal and mechanical indices
related to medical diagnostic ultrasonic fields
WEEE (Waste Electrical and Electronic Equipment)
ROHS according to 2011/65/EU

†Not for sale in the USA. Not approved or cleared by the U.S. FDA.

Please contact your GE Sales Representative for information about


availability in your area.

GE Healthcare Europe © 2018 General Electric Company – All rights reserved.


9900 Innovation Drive GE Healthcare
Wauwatosa, WI 53226 Beethovenstr. 239 General Electric Company reserves the right to make changes in
U.S.A. specifications and features shown herein, or discontinue the product
42655 Solingen
described at any time without notice or obligation. Contact your GE
Germany Representative for the most current information.
www.gehealthcare.com APAC * GE, GE monogram, Voluson, HDlive, SonoAVC, SonoVCAD, SonoNT, B-Flow,
GE Healthcare Asia Pacific HD-Flow, and CrossXBeamCRI are trademarks of General Electric Company
4-7-127, Asahigaoka, or one of its subsidiaries.
Hino-shi, Tokyo 191-8503
Japan ** Windows is a registered trademark of Microsoft Corporation.

® DICOM is the registered trademark of the National Electrical


North America
Manufacturers Association for its standards publications relating to digital
GE Healthcare communications of medical information.
9900 W. Innovation Drive
Wauwatosa, WI 53226 GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC, a General
USA Electric company, doing business as GE Healthcare.

DOC2154319

Voluson E8 BT19 Datasheet Page 18 of 18

S-ar putea să vă placă și