Sunteți pe pagina 1din 2

E ERCO GmbH

Postfach 24 60
58505 Lüdenscheid
English
- Please read these instructions carefully
before installation and commissioning
Mounting options
- The luminaires are suitable for instal-
lation in underfloor electrical trunking
with screed covering, hollow floors, hol-
Brockhauser Weg 80-82 and hand over to the customer for low walls or suspended ceilings having
58507 Lüdenscheid retention. a minimum thickness of 10mm.
- Our updated product documentation - Separate recessed housings are avail­
Germany can be accessed at able for installation in plastered brick-
www.erco.com/download. work and concrete.
Tel.: +49 2351 551 0
Fax: +49 2351 551 300 Required accessories Mounting
The luminaire should be operated using Installation in underfloor electrical
info@erco.com the appropriate ERCO control gear. No trunking with screed covering, hol-
www.erco.com responsibility is accepted if used with low floors, hollow walls or suspended
equipment supplied by other manufac­ ceilings
turers. Note: Installation requires a minimum
Orientation luminaires General safety information
recess depth of 70mm.
1. Prepare an installation opening of
Warning! ∅ 32mm or ∅ 45mm to a tolerance of
Mounting instructions Risk of electric shock!
Before carrying out maintenance and
+1mm/-0mm.
2. Insert mounting bush “A”.
installation on the luminaire, discon- 3. Pull the connection cable out of the
nect from the mains supply and ensure installation opening.
that all power is switched off. Note: Use the separate tool kit for
- The cable must be connected on site installation in ducts.
to ensure the necessary IP rating and to Installation in plastered brickwork
the required protection class. using a separate flush-mounted
- Never operate luminaires with damaged recessed housing.
connection cables. See recessed housing instructions
Attention! (3000042827).
- Do not open the luminaire. If damaged, - The orientation luminaire can be
the entire luminaire must be returned inserted into the installation housing
to the factory. without mounting bush “A”.
- When installing, always observe the Installation in concrete floors and walls
national installation and accident pre- using a separate recessed housing
vention regulations. See mounting instructions
(3000009992) for recessed housing.
Intended use - The orientation luminaire can be
- The luminaire is dust- and pressure- inserted into the installation housing
water tight. It is protected against the without mounting bush “A”.
consequences of continuous submer-
sion up to a maximum depth of 3m Electrical connection
(IP68 3m). - Ensure connection to control gear
- The luminaire is suitable for both out- with protected low voltage (SELV) acc.
door and indoor use. to EN 61558 or EN 61347.
- The electrical connection must be
Notes on corrosion protection made in a suitable connection compart-
- All recessed in-ground luminaires must ment. Incorrect installation can result
be installed with a suitable drainage in moisture entering the luminaire
system in place, e.g. a gravel bed. Please through the connection cable. It must
ensure that the installation the luminaires be ensured that the cable connection
allows water to run off their surface. is watertight. We recommend using
- Ensure that the powder coating is not coupling or branch sleeves and two-
damaged during installation or mainte- component cast resin jointing.
nance work. Any damage, which becomes - The cable gland must not be opened.
wet, can result in corrosion occurring. - If the free end of the cable from
The luminaire is approved for use in the orientation luminaire is to be laid
grounds with a pH value of 5 to 8. In directly in the ground, it must be suit­ably
aggressive environments, the installation contained in a protective conduit (sup-
and maintenance of all parts will require plied by the installer).
appropriate protective measures. Chemi- 1. Connect the connection cable to the
cals damage the corrosion protection. luminaire.
2. For through-wiring, also connect the
Choosing the mounting location continuing cable.
Position the luminaire so as to avoid
operation in direct sunlight or near Wiring connections
other sources of heat. High ambient Type 12V/24V
temperatures can reduce the life and 1 Red +12V/24V DC
efficiency of the control gear or LED 2 Black - GND
3000038114 module.
0119
1
Final installation
1. Before final installation, conduct a
general function test.
2. Check the alignment of all luminaires
and insert each into its mounting bush
“A” or into the installation openings of
the concrete or flush-mounted recessed
housing.
Note: Floor washlights are positioned
with the ERCO logo facing up.

Dimming
The luminaires cannot be dimmed.

Information on the safety glass


Safety information
- There is an increased risk of slipping
on wet glass.
- If the safety glass is defective, the
entire luminaire must be replaced.
Load
The safety glass used can withstand a
load of 5000N.
Loads caused by hard objects, impacts
or blows must be avoided.
Surface temperature
Approx. 5°C above ambient temperature
(max. ambient temperature 35°C).

Cleaning
Always clean carefully using a soft
cloth and a commercially available,
ph-neutral, alcohol-free, non-abrasive
cleaning agent.
Cleaning the safety glass
Safety glass can be cleaned with clean-
ing agents that are also suitable for
glass-ceramic cooking hobs.

Disposal
In accordance with EU Directive
WEEE (Waste Electrical and Elec-
tronic Equipment), luminaires must not
be disposed of with other household
waste. At the end of their life, lumi-
naires must be taken to the appropriate
local facility available for the disposal
or recycling of electronic products.